What is Automatic Pumping System-PRO (APS-PRO)? Ver.0.2

Ver.0.2
What is Automatic Pumping System-PRO (APS-PRO)?
APS-PRO is designed for easy humidification by adapting new tubing system developed by Autoelex which is attachable and
detachable with 4 rollers increasing durability. It can be available in every use to pump up the water, especially for other brand incubator.
APS-PRO is originally designed for the incubators which have no humidity control function.
APS PRO can be easily applied with other branded incubators which do not have humidification function.
It can be assembled simply, and check or control temp. and humidity inside of incubator.
1. Assembled picture & Basic components
IN
OUT
INCUBATOR
WATER
FAN
PET bottle
<Expendables>
SENSOR
HEATER
ADAPTOR
3.5cm (diameter : Þ2.6 - 3.5)
Silicone Tube and Nipple (2pcs.)
Bolt : 2pcs.
Silicon Tube : 1.5m
(diameter : Þ2.6 * 3.5)GG
Pump
Evaporatingpad (A5 size)
QExpendables
Pin : 2pcs.
Manual
Humi. & Temp.
Sensor
Humidity & Temperature
Display
Easy Operation
Manual
Adaptor(12V)
Manual
2. How to Use APS
35mm
a
35mm
[Pic.1-3]
[Pic.1-4]
[Pic.1-6]
[Pic.1-5]
2-1. How to Assemble
① Cut the silicone tube exactly to 35mm, and insert to nipple as picture 1-4.
(When you purchase, product is originally assembled as ⓐ.)
c
If you do not insert silicone tube completely, it will not work well.
d
b
Turning Direction
② Cut the silicone tube of 1.5m to optimum length, and insert to assembled
nipple ⓐ.
[Pic.1-7]
[Pic.1-8]
③ It is normal if you assembled as pic.1-5. If you do not insert to nipple completely
as pic.1-6, it will not work well.
④ Loose two bolts of APS case, and insert the assembled silicone tub and nipple as pic.1-5 to the side of pic. 1-7 ⓑ.
⑤ Grip the part ⓒ on Pic.1-7, and pull the silicone tube so that fit to ⓓ.
⑥ Spread IN and OUT of tube so that the silicone tube is not tangled. Insert tube on the groove, and cover the case.
Here, be sure to check not the silicone tube or wire get jammed. Refer to the Pic.1-8.
2-2. Easy Operation
Function
How to operate
rH
Humidity Set
1Time
Humidity
Calibration
Temp. & Humi.
Set
or
Calibration
Limits
or
Increase
30sec.
Increase
Auto-saved
Decrease
or
CA
POWER IN
HOLD
Function
30sec.
Auto-saved
Decrease
▶ Humidity Set : 20% ~ 80% (Default setting : 45%)
▶7HPSHUDWXUH6HWÛ&aÛ&'HIDXOWVHWWLQJÛ&
▶ Humidity Calibration : -20% (20 step) ~ 0 ~ +20%
▶7HPSHUDWXUH&DOLEUDWLRQÛ&$SSUR[VWHSaaÛ&
How to operate
Return to Original
Factory Set
5sec.
Temperature
Set
2Time
rS
tE
Manual Pumping
Operation
Temperature
Display
Return to factory set completed.
or
Increase
Manual Pumping
Operation for
2minutes
5sec.
Press
30sec.
Auto-saved
Decrease
10sec.
button to see the Temperature.
2-3. How to Equip Evaporating Pad
① Cut the evaporating pad as [Pic.2-1], and fold to fix with pins as [Pic.2-3].
Humidification might be different from the size of evaporating pad.
※ Refer to pic.2-2 for inverval of fins.
Below 50% humidity (Cut to 50mm~55mm)
② It is important to keep high humidity when hatching or 1-2 days before hatching.
During incubation, humidity should be kept 45~55% in case of waterfowl, 40~45% in case
of poultry, and 35~45% in case of parrots. At the last stage of incubation(hatching period),
the humidity should be kept over 65% for all species of birds.
Over 60% humidity (Cut to 70mm~75mm)
[Pic.2-1]
At least every 3 days, the water level should be checked. If the water is in shortage,
refill the water. distilled water are better than any other filtered water or underground water
to maintain good performance of evaporating pad
2-4. How to Control Water Flow Speed in the Silicon Tube.
Þ]
▶ The amount of water can be easily controlled with APS.
▶ With cross type screw driver, turn "Speed" clockwise to increase water flow and vice
versa to decrease. [Pic. 2-4]
▶ To prevent from over flooding and drop down in the chamber, use
the APS with lowest water flow speed. (1 drop of water in 3 seconds)
Y
Y\””
[Pic.2-2]
3. How to Replace the Tube
▶ If the silicone tube wear out and it does not pump water effectively, replace silicone tube
as shown the picture 2-1 above.
Be sure to use the silicon tube supplied from Autoelex. (Ø2.6 × 3.5)
4. Storage and Cleaning
▶ Do not wash with water but wipe with soft cloth.
▶ In case of long time storage, detach the silicon tube from the APS and remove the water
from the tube. Keep the tube without kink. It helps the tube hole not block.
▶ When assembling again, stretch the tube to open the hole in case the tube is blocked.
[Pic.2-3]
5. Pumping Failure and The Solution
▶ Water does not pumping out, or abnormal noise comes out even if pump is working,
silicon tube could be folded and blocked.
※ When it does not work, please check below.
1. whether place water-in tube and water-out tube on right direction.
2. whether the motor works to an anticlockwise direction.
3. whether cut the silicon tube to 35mm exactly and fully insert.
※ If you still have the problem, please inquire to manufacturer Autoelex co.,Ltd. or the
distributor in your country.
v|{
1 drop per 3 sec.
[Pic.2-4]
6. Specifications
Name
Input Voltage
Power Consumption
Dimension
Weigh
Display
Control System
sensor
Heater
Heat controller
Evaporating pad
APS PRO
APS PRO DIY
12V(12V adaptor included)
25mA
(W)75×(D)28×(H)100(mm)
120g
150g
Humidity(Temperature)
Self humidity control
Humidity, Temp. Fan, Heater Control
Up to 350W 100~110V : 3A / 220~240V : 1.5A
MANUFACTURER
ú)FBE0GGJDF%FPLBN+VDIPO(JNIBF
,03&"
%JSFDUUPTBMFTUFBN
ú5&_0GGJDF
ú'"9
ú&."*3DPN!3DPNDPLS