RNA CVC 123 Calibration Verification Controls How to Locate a Calibration Control Lot 1. Select Bookmark tab on left: 2. Locate RNA Kit #: x Select appropriate kit x Please note specific sheets for mmHg vs kPa, or the H4 or GL cartridge 3. To Find a Specific Level and Lot: x Open file by selecting the “+” icon x The expanded list of control levels will display: IRMA TruPoint® Calibration Verification Control For use with the RNA Medical, Inc. CVC 123 Calibration Verification Controls RNA Medical CVC 123 Calibration Verification Control Lot 212319 Level 1 Lot 14116 Level 2 Lot 11522 Level 3 Lot 11621 Level 4 Lot 11722 Level 5 Lot 14217 EXP. 11/14 For use with CC, BG, and H3 Cartridges Expected Values Chart * LEVEL 1 2 3 4 5 LEVEL 1 2 3 4 5 LOT NUMBER 14116 11522 11621 11722 14217 LOT NUMBER 14116 11522 11621 11722 14217 pH pCO2 mmHg pO2 mmHg 6.842 – 6.902 7.126 – 7.186 7.408 – 7.468 7.606 – 7.666 7.849 – 7.909 80.1 – 104.1 64.1 – 80.1 36.2 – 46.2 16.4 – 26.4 6.2– 16.2 36.1 – 66.1 69.9 – 89.9 104.4 – 124.4 147.1 – 167.1 425.2 – 545.2 Na+ mM K+ mM iCa mM 84.8 – 94.8 107.6 – 117.6 128.0 – 138.0 155.2 – 165.2 164.1 – 174.1 9.16 – 12.16 1.44 – 2.44 3.83 – 4.83 5.76 – 6.76 1.19 – 2.19 2.15 – 3.15 1.27 – 1.47 0.97 – 1.17 0.43 – 0.63 ORL** The values on the Expected Values Chart are based on the results of multiple sample analysis. Samples were drawn with a 3cc syringe, 15 gauge plastic needle tip, after equilibration at 22°C (72°F) for a minimum of 8 hours. Use the expected values for each parameter as a guide in evaluating performance. Since performance is subject to sample temperature and environmental barometric pressure, ITC recommends that each institution establish its own expected values and acceptable limits. The mean values established at your institution should fall within the expected ranges. *NOTE: These values are for use with the IRMA TruPoint only. **ORL = Out of Range Low Calibration Verification Control 123 212319_CC 1211 IRMA TruPoint® Calibration Verification Control For use with the RNA Medical, Inc. CVC 123 Calibration Verification Controls RNA Medical CVC 123 Calibration Verification Control Lot 212319 Level 1 Lot 14116 Level 2 Lot 11522 Level 3 Lot 11621 Level 4 Lot 11722 Level 5 Lot 14217 EXP. 11/14 For use with Glucose (GL) Cartridges Expected Values Chart * LEVEL LOT NUMBER Na+mM K+mM Cl-mM 1 2 3 4 5 14116 11522 11621 11722 14217 85.7 - 95.7 107.3 - 117.3 128.4 - 138.4 155.8 – 165.8 164.2 – 174.2 8.95– 11.95 1.54– 2.54 3.79 – 4.79 5.63 – 6.63 1.25 – 2.25 52.7 – 62.7 64.3 – 74.3 86.9 – 96.9 120.2 – 130.2 134.0 – 144.0 Glucose mg/dL 375- 475 50 – 80 163 – 203 256 – 316 ORL** The values on the Expected Values Chart are based on the results of multiple sample analysis. Samples were drawn with a 1mL syringe, 15 gauge plastic needle tip, after equilibration at 22°C (72°F) for a minimum of 8 hours. Use the expected values for each parameter as a guide in evaluating performance. Since performance is subject to sample temperature and environmental barometric pressure, ITC recommends that each institution establish their own expected values and acceptable limits. The mean values established at your institution should fall within the expected ranges. *NOTE: These values are for use with the IRMA TruPoint only. **ORL = Out Of Range Low Calibration Verification Control 123 212319_GL 0112.doc1014 IRMA TruPoint® Calibration Verification Control For use with the RNA Medical, Inc. CVC 123 Calibration Verification Controls For use with H4 Cartridges RNA Medical CVC 123 Calibration Verification Controls Lot 212319 Level 1 Lot 14116 Level 2 Lot 11522 Level 3 Lot 11621 Level 4 Lot 11722 Level 5 Lot 14217 EXP. 11/14 Expected Values Chart * LEVEL LOT NUMBER Na+mM K+mM CI-mM 1 2 3 4 5 14116 11522 11621 11722 14217 84.7 – 94.7 110.2 – 120.2 127.3 - 137.3 155.7 – 165.7 164.9 – 174.9 9.40 – 12.40 1.58 - 2.58 3.63 - 4.63 5.37 - 6.37 1.24 - 2.24 59.9 -69.9 68.6 - 78.6 85.5 – 95.5 108.8 – 118.8 119.2 – 129.2 BUN mg/dL ORL** 7 - 13 27 - 37 46 - 62 ORL** The values on the Expected Values Chart are based on the results of multiple sample analysis. Samples were drawn with a 3cc syringe, 15 gauge plastic needle tip, after equilibration at 22°C (72°F) for a minimum of 8 hours. Use the expected values for each parameter as a guide in evaluating performance. Since performance is subject to sample temperature and environmental barometric pressure, ITC recommends that each institution establish their own expected values and acceptable limits. The mean values established at your institution should fall within the expected ranges. *NOTE: These values are for use with the IRMA TruPoint only. **ORL = Out Of Range Low CVC 123_H4_212319_1114 IRMA TruPoint® Calibration Verification Control For use with the RNA Medical, Inc. CVC 123 Calibration Verification Controls For use with Lactate (LA) Cartridges RNA Medical CVC 123 Calibration Verification Control Lot 212319 Level 1 Lot 14116 Level 2 Lot 11522 Level 3 Lot 11621 Level 4 Lot 11722 Level 5 Lot 14217 EXP. 11/14 Expected Values Chart * LEVEL LOT NUMBER 1 2 3 4 5 14116 11522 11621 11722 14217 Lactate mmol/L ORH** 0.5 – 1.1 2.2 – 3.2 5.6 – 8.6 ORH** The values on the Expected Values Chart are based on the results of multiple sample analysis. Samples were drawn with a 1mL syringe, 15 gauge plastic needle tip, after equilibration at 22°C (72°F) for a minimum of 8 hours. Use the expected values for each parameter as a guide in evaluating performance. Since performance is subject to sample temperature and environmental barometric pressure, ITC recommends that each institution establish their own expected values and acceptable limits. The mean values established at your institution should fall within the expected ranges. *NOTE: These values are for use with the IRMA TruPoint only. **ORH= Out Of Range High Calibration Verification Control 123_LA_212319_1114.doc IRMA TruPoint® Calibration Verification Control For use with the RNA Medical, Inc. CVC 123 Calibration Verification Controls RNA Medical CVC 123 Calibration Verification Control Lot 212320 Level 1 Lot 24117 Level 2 Lot 21523 Level 3 Lot 21622 Level 4 Lot 21723 Level 5 Lot 24219 EXP. 05/15 For use with CC, BG, and H3 Cartridges Expected Values Chart * LEVEL 1 2 3 4 5 LEVEL 1 2 3 4 5 LOT NUMBER 24117 21523 21622 21723 24219 LOT NUMBER 24117 21523 21622 21723 24219 pH pCO2 mmHg pO2 mmHg 6.848 – 6.908 7.136 – 7.196 7.409 – 7.469 7.616 – 7.676 7.850 – 7.910 79.5 – 103.5 62.8 – 78.8 37.9 – 47.9 16.2 – 26.2 6.2– 16.2 28.4 – 58.4 66.1 – 86.1 102.5 – 122.5 147.9 – 167.9 425.5 – 545.5 Na+ mM K+ mM iCa mM 85.2 – 95.2 107.6 – 117.6 129.9 – 139.9 158.1 – 168.1 164.8 – 174.8 9.19 – 12.19 1.48 – 2.48 3.86 – 4.86 5.88 – 6.88 1.23 – 2.23 2.17 – 3.17 1.28 – 1.48 0.99 – 1.19 0.43 – 0.63 ORL** The values on the Expected Values Chart are based on the results of multiple sample analysis. Samples were drawn with a 3cc syringe, 15 gauge plastic needle tip, after equilibration at 22°C (72°F) for a minimum of 8 hours. Use the expected values for each parameter as a guide in evaluating performance. Since performance is subject to sample temperature and environmental barometric pressure, ITC recommends that each institution establish its own expected values and acceptable limits. The mean values established at your institution should fall within the expected ranges. *NOTE: These values are for use with the IRMA TruPoint only. **ORL = Out of Range Low IRMA TruPoint® Calibration Verification Control For use with the RNA Medical, Inc. CVC 123 Calibration Verification Controls For use with Glucose (GL) Cartridges RNA Medical CVC 123 Calibration Verification Controls Lot 212320 Level 1 Lot 24117 Level 2 Lot 21523 Level 3 Lot 21622 Level 4 Lot 21723 Level 5 Lot 24219 EXP. 05/15 Expected Values Chart * LEVEL LOT NUMBER Na+mM K+mM Cl-mM 1 2 3 4 5 24117 21523 21622 21723 24219 86.2 – 96.2 107.1 – 117.1 129.3 – 139.3 156.3 – 166.3 162.5 – 172.5 8.66 – 11.66 1.51 - 2.51 3.72 - 4.72 5.54 - 6.54 1.26 - 2.26 51.9 -61.9 63.3 - 73.3 86.3 – 96.3 117.6 – 127.6 128.9 – 138.9 Glucose mg/dL 356- 456 56 – 86 166 – 206 264 – 324 ORL** The values on the Expected Values Chart are based on the results of multiple sample analysis. Samples were drawn with a 1mL syringe, 15 gauge plastic needle tip, after equilibration at 22°C (72°F) for a minimum of 8 hours. Use the expected values for each parameter as a guide in evaluating performance. Since performance is subject to sample temperature and environmental barometric pressure, ITC recommends that each institution establish their own expected values and acceptable limits. The mean values established at your institution should fall within the expected ranges. *NOTE: These values are for use with the IRMA TruPoint only. **ORL = Out Of Range Low Calibration Verification Control 123 Glucose GL_212320_0515 IRMA TruPoint® Calibration Verification Control For use with the RNA Medical, Inc. CVC 123 Calibration Verification Controls For use with H4 Cartridges RNA Medical CVC 123 Calibration Verification Controls Lot 212320 Level 1 Lot 24117 Level 2 Lot 21523 Level 3 Lot 21622 Level 4 Lot 21723 Level 5 Lot 24219 EXP. 05/15 Expected Values Chart * LEVEL LOT NUMBER Na+mM K+mM CI-mM 1 2 3 4 5 24117 21523 21622 21723 24219 84.8 – 94.8 106.9 – 116.9 128.6 – 138.6 154.0 – 164.0 159.3 – 169.3 9.63 – 12.63 1.61 - 2.61 3.91 - 4.91 5.71 - 6.71 1.22 - 2.22 58.1 -68.1 69.7 – 79.7 85.6 – 95.6 112.7 – 122.7 121.5 – 131.5 BUN mg/dL ORL** 6 - 12 28 - 38 47 - 63 ORL** The values on the Expected Values Chart are based on the results of multiple sample analysis. Samples were drawn with a 3cc syringe, 15 gauge plastic needle tip, after equilibration at 22°C (72°F) for a minimum of 8 hours. Use the expected values for each parameter as a guide in evaluating performance. Since performance is subject to sample temperature and environmental barometric pressure, ITC recommends that each institution establish their own expected values and acceptable limits. The mean values established at your institution should fall within the expected ranges. *NOTE: These values are for use with the IRMA TruPoint only. **ORL = Out Of Range Low CVC 123_H4_212320_0515 IRMA TruPoint® Calibration Verification Control For use with the RNA Medical, Inc. CVC 123 Calibration Verification Controls For use with Lactate (LA) Cartridges RNA Medical CVC 123 Calibration Verification Control Lot 212320 Level 1 Lot 24117 Level 2 Lot 21523 Level 3 Lot 21622 Level 4 Lot 21723 Level 5 Lot 24219 EXP. 05/15 Expected Values Chart * LEVEL LOT NUMBER 1 2 3 4 5 24117 21523 21622 21723 24219 Lactate mmol/L ORH** 0.6 – 1.2 2.3 – 3.3 5.8 – 8.8 ORH** The values on the Expected Values Chart are based on the results of multiple sample analysis. Samples were drawn with a 1mL syringe, 15 gauge plastic needle tip, after equilibration at 22°C (72°F) for a minimum of 8 hours. Use the expected values for each parameter as a guide in evaluating performance. Since performance is subject to sample temperature and environmental barometric pressure, ITC recommends that each institution establish their own expected values and acceptable limits. The mean values established at your institution should fall within the expected ranges. *NOTE: These values are for use with the IRMA TruPoint only. **ORH= Out Of Range High Calibration Verification Control 123_LA_212320 IRMA TruPoint® Calibration Verification Control For use with the RNA Medical, Inc. CVC 123 Calibration Verification Controls RNA Medical CVC 123 Calibration Verification Control Lot 312321 Level 1 Lot 34118 Level 2 Lot 31525 Level 3 Lot 31624 Level 4 Lot 31725 Level 5 Lot 34220 EXP. 08/16 For use with CC, BG, and H3 Cartridges Expected Values Chart * LEVEL 1 2 3 4 5 LEVEL 1 2 3 4 5 LOT NUMBER 34118 31525 31624 31725 34220 LOT NUMBER 34118 31525 31624 31725 34220 pH pCO2 mmHg pO2 mmHg 6.830 – 6.890 7.128 – 7.188 7.408 – 7.468 7.614 – 7.674 7.846 – 7.906 84.4 – 108.4 64.8 – 80.8 37.2 – 47.2 16.4 – 26.4 6.8– 16.8 24.8 – 54.8 63.6 – 83.6 99.4 – 119.4 143.8 – 163.8 416.2 – 536.2 Na+ mM K+ mM iCa mM 85.0 – 95.0 107.6 – 117.6 129.1 – 139.1 156.6 – 166.6 163.3 – 173.3 9.12 – 12.12 1.48 – 2.48 3.86 – 4.86 5.80 – 6.80 1.21 – 2.21 2.12 – 3.12 1.25 – 1.45 0.98 – 1.18 0.42 – 0.62 ORL** The values on the Expected Values Chart are based on the results of multiple sample analysis. Samples were drawn with a 3cc syringe, 15 gauge plastic needle tip, after equilibration at 22°C (72°F) for a minimum of 8 hours. Use the expected values for each parameter as a guide in evaluating performance. Since performance is subject to sample temperature and environmental barometric pressure, ITC recommends that each institution establish its own expected values and acceptable limits. The mean values established at your institution should fall within the expected ranges. *NOTE: These values are for use with the IRMA TruPoint only. **ORL = Out of Range Low Calibration Verification Control 123 10-25-10_CC Template
© Copyright 2024