-How to use vour Water Heaier Features Safety Points Remote Controls Explained Turning System ON Adjusting Temperature Rinnai Infinity 16 Customer tipage Installer *page 2 Turning System OFF Optional Remote Control Transfer Function About Hot Water Error Messages Installation Service Contacts 14 < < < < < < < < < < < < 2 3 5 7 8 8 9 10 11 13 14 27 This appliance shall be installed in accordance with: l l l l Manufacturer’s Instructions Local Authority Building Codes NZS 5261 Installation Code for Gas Burning Equipment Any other relevant Statutory Regulation This appliance must be installed, serviced and removed by an authorised person. This Infinity 16 must be installed correctly by an authorised person. of gas, water, and electricity must conform to local regulations. The installation The installation must also comply with the instructions supplied by Rinnai. Your Infinity 16 has been approved by the Australian Gas Association. A.G.A. Approval Please keep this instruction All dimensions Number 5112. booklet in a safe place for future reference. referred to in these instructions unless otherwise specified. -l- are in millimetres, The Infinity 16 is one of a range of the most advanced 1 water heaters available. The Infinity 16 is an externally mounted, saving both floor and wall space power flued appliance. The Kitchen Remote Control fitted in the kitchen or other convenient A second, Bath Control The Kitchen Control is normally (Optional) is avsailable for fitting in a bathroom selects temperature The temperature selected on the Remote water that will be supplied at the tap. The temperature It is very compact, for the kitchen, Control selected at the remote control laundry, is the maximum is retained area. or ensuite. etc. temperature of hot in the system memory. The Infinity never runs out of hot water. While electricity, water and gas supplies connected. hot water is available whenever the hot water tap is open. are The burner lights automatically when the hot water tap is opened, and goes out when the tap is closed. Ignition is electronic; there is no pilot light. When the hot water tap is off, no gas is used. A.G.A.‘s 4 Star Energy Rating shows that the Inlinity water heaters available. 16 is one of the most efficient Built into the main micro-processor is the facility to LIMITTHE MAXIMUMTEMPERATURE of the hot water supplied by the Infinity 16. The water temperature may be limited to 40-C, 5O’C or 55°C. This is particularly useful when the Infinity I6 is installed where young children or the infirm may be using the hot water. If required, the temperature limits can be set by a service technician. For further information, please contact Rinnai. Operating noise level is very low. Error messages are displayed on the Remote -2- Control, assisting with service. Always check water temperature by hand before entering the shower or bath. The temperature may have been The water temperature cannot be adjusted when the hot water tap is Depending on the weather conditions and the length of the pipe between the Infinity 16 and the tap in use, there may be a variation between the temperatures displayed at the Remote Control and the temperature of the water at the tap. In areas incoming with very cold water tempera- temperature, there may be a difference between the temperature displayed on the remote control and the temperature of the hot water at the tap. To increase the temperature of hot water to that shown on the control, simply reduce the water flow at the hot tap manually. There is no need to turn the Infinity 16 off at the Remote Control after use. However, if you prefer to turn the Water flow needs to be more than 2.5L/min. to operate the Infinity 16. Hot water temperature may vary at low water flows, or the Infinity 16 ‘may go out without warning. will be stored in the system memory at all times while mains power remains connected. -3- Do not clean the Remote Control with solvents. Use a soft damp cloth. Do not touch cover or insert objects into the flue outlet when the Infinity 16 is in operation. ‘, On cold days steam may be discharged from the flue outlet, this is normal with a high efficiency appliance and does not indicate a fault. Spray If the Infinity 16 is disconnected from the power supply and freezing conditions are expected, turn off water and gas, and drain all water from the appliance. Keep flammable materials, trees, shrubs etc. away from the Infinity 16. Water Off \1 Gas Off & Drain Water If paverandmeautcmatic frost protection is connected, freezing will be prevented. (Y Series onlY) terminal. With optional second remote control fitted. If a temperature higher than 50°C has been selected at the Kitchen Control and then priority of temperature selection is transferred to a Bath Control and back again, the temperature on the Kitchen Control will drop to 5O’C. This is a safety feature. Do not push the-1 button on the Kitchen Control after having transferred priority of temperature selection to the Bath Control. -4- This remote control is supplied with the Infinity 16. selected. Error message es in the event of a contra 1s m cmtro 0 temperature, when thr optional second remote *This remote control is also suitable for installation in laundry areas. -5- This remote control is available an option for the Infinity 16. selected. Error code flashes I of the hot water. ndlcates which remote control is in control of adjusting water Refer to page 9 for operating instructions with the optional remote control fitted. control as for use in the bathroom. -6. as To TURN ON your hot water system, Press the ON/OFF button on the remote control. After Installation, To obtain the best performance the Remote Control correctly. from your Infinity The purpose of the Remote Control Infinity 16 from inside your house. Adjustments and when the ON/OFF 16 it is important button is to use is to enable you to have control over your to the operation of your Infinity 16 can be made with the Remote Control. Various water temperatures can be selected in 14 steps from 37°C to 55°C. temperatures are 37-38-3%40-41-42-43-44-4546-47-48-50-55-C. / SHOWER Suggested temperatures are The KITCHEN I , Shower 42°C Kitchen 50°C. These temperatures are suggested starting points for selection. You may find higher or lower temperatures are more comfortable. Maintaining lower temperatures helps to save energy. To obtain water temperatures lower than 37°C simply add cold water. -7- HOT COLD OPERbTlON The yellow ON indicator will glow on the Remote Control. This indicates that the Infinity 16 is ready to supply hot water as soon as a tap is opened. I To operate the Infinity 16 simply turn any hot water tap on. This will automatically light the burner, providing hot water up to the temperature displayed on the Digital Monitor. The red operation indicator will glow on the remote control. When the tap is turned off, the burner goes out automatically. I To TURN OFF 0 required temperature is displayed on the Digital Monitor. Simply press the -1 on any Remote Control. button This will shut the Infinity 16 down. The ON indicator will go out. If hot water taps are opened when the Infinity 16 is OFF; cold water will flow,from the taps. CHECK WATER TEMPERATURE BEFORE ENTERING SHOWER OR BATH. *Always test the water temperature in bath before a child gets in. This is best done by the parent placing their elbow in the water. -0- Additional SAFETY features The Transfer button on the Bath Control enables you to select and lock the preferred temperature for shower or bath water. When locked in. this selected temperature cannot be overridden by the Kitchen Control. While the hot water tap is open, the following safety features apply. *Temperature selection cannot be transferred. (When optional Bath Control is fitted.) l Water temperature cannot be altered. *The Remote Control cannot be turned ON. The temperature of outgoing hot water is constantly monitored by a built in sensor. If the temperature of the outgoing hot water rises to more.than 3’C above the selected temperature shown on the Digital Monitor, the burner will automatically go out. The red operation lamp will also go out. The burner will ignite again once the outgoing hot water temperature falls to that shown on the Digital Monitor. Usingthe Infinity16 withOptionalControl To TURN ON your hot water system, Press the ON/OFF button on either remote control. ADJUSTING TEMPERATURE The temperature can only be adjusted on the Remote Control where the ON indicator is glowing, and the same temperature will be displayed on all Controls. After Installation, be displayed and when the ON/ on the Digital Monitor. -9- The Transfer button on the Bath Control (Optional Control), enables you to select and lock the preferred temperature for shower or bath water. When locked in, this selected temperature cannot be overridden by the Kitchen Control. To transfer priority of water temperature selection to the Bath Control, simply press the ITRANSFER I button on the Bath Control. The ON indicator on the Bath Control will glow to indicate that priority of water temperature selection has been transferred to the Bath Control. a The water temperature can now be selected using the Bath Control. The maximum temperature which can be selected at the Bath Control is 50%. This is to help reduce the risk of burns from hot water. A different temperature can be stored in the system memory of the Bath and Kitchen Controls. 8 After having transferred the priority of water temperature selection, 40°C will be displayed on the Digital Monitor. Burns from hot tap water can result in very severe injuries to young children. Hot water at 65’C (the average hot water temperature in Australia) can severely burn a child in less than half a second. At 50°C it takes five minutes. Burns can happen when children turn on the hot water tap and they are under it, or when they are placed into a bath which is too hot. To transfer priority of water temperature selection back to the Kitchen Control, simply press the m button again. The temperature displayed will then return to the temperature which was previously selected at the Kitchen Control, or 5O’C, whichever is the lower. The ON indicator on the Kitchen Control will glow to indicate priority control of water temperature selection. Priority temperature selection cannot when a hot water tap is open. - 10 - be transferred Excessively hot water is dangerous, especially for young children and the infirm. The Infinity 16 allows you to control the temperature of your hot water to‘safe levels. Water temperature over 50% can cause severe burns instantly or death from scalds. Children, disabled, and the elderly are at highest risk of being scalded. Feel water before bathing or showering. Do stay with children whenever they are in the bathroom. (Take the phone off the hook). Do take them out of the bathroom if you need to answer the phone or door. Do test the temperature of the water with your elbow before placing your child in the bath. Do make sure that the tap is turned off tightly. Do consider setting your Infinity at a maximum temp of SO’C.(Contact Rinnai.) Do install a child proof tap cover OR, Do install a child resistant tap. Don’t leave a toddler in the care of another small child. The older child may not have set the water temperature to a safe level. - 11 - *Consider child-resistant taps or inexpensive tap covers, both of which prevent a small hand being able to turn on the tap. *Consider reducing the temperature of the water coming from the hot tap to 50°C. This approach can be extremely valuable because it requires a one time action for a long-term reduction in the risk of scalds. This type of automatic protection is important during times when a parent or carer has been distracted. 1. REMOVE CLOTHING Remove all wet clothing quickly, as clothing retains the heat. 2. APPLY COLD WATER FOR 30 MINUTES Immediately submerge the burnt area in cold water for SO minutes to reduce the heat in the skin, preventing deeper burning. Never use butter, oils, ointments to cover the burn as they may retain the heat. Never use ice. Children can be dangerously chilled in iced water. 3. KEEP THE CHILD WARM Place a blanket around your child. 4. SEEK MEDICAL ADVICE Seek medical your palm. advice if the scald involves the face or hands or is larger than DEAR CUSTOMER THANK YOU RINNAI PRODUCTS LABOUR FOR PURCHASING THIS ARE NOW COVERED FOR THE FIRST YEAR CONSUMERS LOCAL YOU HAVE ANY RINNAI MAY APPLIANCE. BY A 2 YEAR. AND PARTS - THIS GUARANTEE SHOULD RINNAI ONLY IS IN ADDITION HAVE UNDER QUERIES WE ARE PLEASED GUARANTEE: FOR THE TO ANY GUARANTEES THE CONSUMER REGARDING SECOND information for your own records. Your Retailer: Address: Phone: Date of Purchase: Your Installer: Installer’s Address: Phone: Dale of Installation: - 12 - Licence No. AND WHICH PLEASE AGENT. Please record below the following FREE PARTS THAT YEAR. GUARANTEES THIS GUARANTEE TO ADVISE ACT CONTACT YOUR The Infinity 16 has the ability to check its own operation continuously. If a fault occcurs, an Error Message will flash on the Digital Monitor of the Remote Controls. This assists with diagnosing thefault, and may enable you to overcome a problem without a service call. Please quote the code displayed when enquiring about service. Check gas is turned on at water and gas meter or cylinder. I Check gas is turned on at water heater and gas meter. Check that nothing is Flame Failure obstructing flue outlet. Turn supply to water heater. Eacth Leakage in Appliance Remote Control Safety ~’ Over Temperature Warning Incoming Water Temperature Sensor Outgoing Faulty Water Temperature Sensor Faulty Heat Exchanger ,Sensor 61 Combustion Outlet Faulty Fan Failure Service Call Service Call Service Call Service Call Service Call Service Call Micro-processor Failure Service Call Micro-processor Failure Service Call In all cases, you may be able to clear the Error Message simply hot water tap OFF, try pushing still remains, then ON the loN/OFFI contact Rinnai on gas or Cables Remaininge;;zy heater again. button - If this does not clear the Error OFF, or your 13 - by turning then ON the Message, again. If the Error Message nearest service agent and arrange for a THE FOLLOWING PAGES CONTAIN INFORMATION FOR THE INSTALLER. Please read information page one. printed on The installer is respofisible for the correct installation of your Infinity 16. - 14 - cE n Read warnings on page one before starting installation. H Check for damage, if the Infinity 16 is damaged, contact the supplier or Rinnai. Do not install a damaged appliance before checking with the supplier or Rinnai. n One Remote Control and accessories are packed inside the carton. Check that the Infinity 16 supplied is correct for the gas type in the area. Refer to local gas authority for confirmation of gas type if in doubt. Refer to data plate located on left hand side panel of the Infinity 16. n Remove the Infinity 16 and accessories from carton, and check that all the parts shown below are included. The Remote Control cable is provided with horse shoe lugs already attached. Remote Control Wall Bracket Cable Screws Horse Shoe Lugs - 15 - n The Infinity 16 is an externally mounted, power flued appliance. BE FITTED OUTSIDE THE BUILDING. IT MUST ONLY w When determining a suitable position for thelnfinity 16, the length of hot water pipe runs should be taken into consideration. In principle, the Infinity 16 should be as close as possible to the most often used taps, or in a central location between taps, showers etc. n Minimum mounting height from the ground is 1500 mm. n See diagram on page 24 for position of gas, water and power connections. n The location of the flue terminal must comply with the clearances shown below. a- Below eaves, balconies or other projections:. bcd*I Bh- i k“- Framthegroundorabove abalcOny . . .._...._........................... From a return wall or external corner Fromagasmeter(M) . . . . . . . . . . . . . . . . . . . . . . .._._........_..................... Fromaneleckidtymeterarfusebox(P) . . . . Fromadrainorsoflpipe . . .. . . Horizontally kom any building strwhlre or obstruction lacing a terminal ,. From any other llue twminaf. cowl,or combustion au mtake Horizontally horn an openable window, dwr, inlet, or any Other opening into a building, with the exception ofsub-floorvenblat~on......................................................... From a mechanical air inlet, including a spa blower.. Vertically below an open&Se window. inlet or any other opening into a building. with the exception 01 sub-flwr vsntllatan................................................................... .._...._...... . . 500 1500 500 1000 500 150 500 500 500 1500 500 Note: If you are unsure about clearances not indicated here, in general refer to l NZS 5261 Installation Code for Gas Burning - 16 - Equipment PIPESIZING IS IMPORTANT. This guide will help you IO size the gas pipe for this appliance correctly. Calculate the length of pipework and total load in MJA. Shaded boxes indicate MJlh capacity of pipe. - 17 - W INFINITY 16 A 230V weatherproof infinity 16. earthed power point is required within 1500 mm of the The Infinity 16 weighs 15 kg, and the wall on which it is lo be mounted must be capable of supporting it and the pipework. Ensure that suitable fixing screws or bolls are used to secure the Infinity 16 to the wall. Bracket and fixing hole locations are shown on page 24. The top bracket has a keyhole slot so that the Infinity 16 can be positioned hanging it on one screw, then the other screws can be secured. After determining the most suitable position, fix the Infinity 16 to the wall. Connect hot and cold the cold water inlet. pressure limiting valve Water connections are by water pipes. An approved gate valve MUST BE FITTED to In areas where the waler pressure is over 1000 kPa, a must also be fitted. Locations are shown on page 24. P&/15. Connect the gas. CHECK PIPE SIZING REQUIREMENT PIPE SIZING CHART. USING AN APPROVED IF THE GAS PIPE SIZE IS INSUFFICIENT, THE CUSTOMER WILL NOT GET THE FULL PERFORMANCE BENEFIT. An The Infinity 16 uses 125 MJh of gas. approved isolation valve MUST BE FITTED to the gas inlet. FP/4/20. This is not an indication of the size of pipe required. Connection size is The Infinity 16 waler heater is not suitable for use as a pool heater. n REMOTE CONTROL The Remote Control enables the customer to control the functions of the Infinity 16 from inside the house. Before fitting the Remote Control, determine the most convenient position for installation where the customer will benefit the most. The MC-33-1A Kitchen Control is intended to be fitted in the kitchen or other convenient area where the majority of hot water is being used. An optional BC-451A Bath Control is intended to be fitted conveniently close to the shower, in the bathroom, en-suite or other area where the customer requires priority over water temperature selection. The BC-451A Bath Control enables the person in the shower/bath area to lock in the selected water temperature, so that the temperature cannot be changed from the MC-33-1A Kitchen Control. - I8 - H When deciding on the best position(s) for the Remote Control(s), the following points should be taken into consideration. 1. Fit the Remote Control(s) out of reach of children. (Suggested height from floor1500 mm). 2. Avoid positions where the Remote Control will become hot (eg: over hotplates, near ovens or heaters. 3. If possible, avoid direct sunlight (The Digital Monitor is difficult to read in direct sunlight). 4. Avoid areas where Remote Control will be affected by oil splashing or cooking. 5. The BC-451A(Optional) Bath Control is water resistant, however it should not be positioned where it may be splashed directly (ie: shower recess). 6. The cable to the Remote Control only carries12 V DC (extra low voltage), 7. Cable should run back to the Infinity 16 from the Remote Control, should run between the Controls then back to the Infinity 16. Suggested cable arrangments are shown below. or cables The installation in every application will vary, therefore the Remote Control cable has been provided so that you may cut the length accordingly and fit the horse shoe lugs, ensuring a good connection. Installation using one remote control. Installation using two remote controls. The cable is simply piggy-backed at the Infinity 16 or the Kitchen Control. Polarity is not important when connecting cables.,Either colour wire can be connected to either terminal at both the Infinity 16 or Kitchen Control. If more cable is needed, any cable with similar specification on the cable supplied with the Infinity 16 can be used. Maximum length is 50 m. - 19 - NOTE: Please read pages 18 and 19 prior to fitting Remote Controls. W FITTING THE KITCHEN CONTROL Outline of Remote Control W-33-1A \ 0 Determine the most suitable position for the Control. Consider access by children. 0 Fix the wall bracket to the wall as shown. (fig 1) 0 The Remote Control cable is to connect the Remote Control to the Infinity 16. (fig 2) 0 Make a suitable sized hole through the wall in the centre opening of the wail bracket. Run the cable between the Control and the Infinity 16, or refer to page 19, No. 8. +-Securing I 0 Connect the cable to the Control as shown (fig 2). l Attach the Control to the bracket as shown, secure with the single screw at the top (fig 3). Ifig 31 0 The cable clamp and screws are provided to secure the cable to the Remote Control if the cable cannot be run in the wall cavity. In this case, the plastic “Knockout” should be removed from the top or bottom of the Control (fig 4). - 20 - Screw n FllllNG THE OPTIONAL BATH CONTROL BC-45-1A ! :--------.------------* Outline of Remote Control 0 Determine the most suitable position for the Control. Consider access by children. 0 Make 3 holes in the wall, as shown, one for the cable and two for the securing screws. Make sure holes are level. Fit wall plugs (fig 1). i& < > 195 Ifig 1) 0 Run the cable provided between the Control and the Infinity 16, or refer to page 19, No.8. 0 Remove the faceplate from the Remote Control using a screwdriver (fig 2). -To Control Remote COntrOl Cable l Connect the BC-451A Control to the cable, using the end of the cable COlllVXtOr with the connector fitted (fig 3). (fig 3) r 0 Fix the Control to the wall, and replace the faceplate (fig 4). F&e Plate (fig 4) - 21 - n CONNECTING REMOTE CONTROL CABLE TO THE INFINITY 16. l Disconnect power. 0 Remove the cover from the Infinity 16 (4 screws) (fig 1). 0 Remove plastic cover from PCB and electrical connections. l Thread the cable through the (fig 1) cable access hole at the base of the Infinity 16, then connect to the Remote Control terminal on the right hand side of P.C.B. unit (fig 2). 0 Horse shoe lugs must be used at both the water heater connection and the Kitchen Control. Short circuits and bad connections caused by bare wires may cause the heater to malfunction. Remote Control Cable 0 Replace plastic cover. (fig 2) l Secure cable inside Infinity 16 Single wire connection, shown connected. Piggy-back the connection in case of two Remote Controls. (Optional Remote Control is availabe separately.) using the clamp provided. n Purge WATER ON Gas and Water pipes to remove air and swarf. Swarf in either gas or water supplies may damage the Infinity 16. - 22 GAS ON W TESTING 0 Turn on Gas and Water, 0 Test for water leaks and gas escapes. Use soapy water to check for gas leaks. 0 Remove pressure test point screw, attach pressure gauge to test point. 0 Turn power on (Caution inside unit). 230V l Turn Infinity 16 on at Kitchen Remote Control. Set temp to 75% (See page 7 and 8). Open any hot water tap fully. Test point Screw and washer 0 Check test point pressure. Information is provided in a pouch, rear of front panel. l If the pressure is low, there could be various reasons eg. warm incoming water, low,water flow, gas pipes too small. Water flow will need to be at least 6 litres/min if incoming water temp. is 15oc. 0 If it is established that the gas pressure needs adjusting, follow the instructions EXACTLY according to the information provided in the pouch, rear of front panel. IF IN DOUBT, CONTACT RINNAI. 0 Turn hot water off. Turn power off. Remove pressure gauge and replace test point screw. 0 Replace front cover (4 stews). 0 Turn power on. Turn Infinity ON at Remote Control. SET CONTROL 16 0 Check operation of appliance by ensuring that the Remote Control(s) are functioning correctly. 0 Explain the operation of the Infinity 16 to the customer. Make sure the customer understands the instructions, in particular the instructions for the Remote Control(s). HOT WATER TAP OPEN NOTE: The regulator is factory pre-set, it should not need adjusting. Check incoming pressure before attempting to make any change to the appliance regulator. FAULT/FAILURE PROCEDURE If you are unable to get the Infinity 16 to operate correctly, contact Rinnai, or your local agent. - 23 INFINITY 16 COLD WATER INLET REMOTE CONTROLS f - 195 c 2 Bath Control BC-451A(Optional) - Kitchen Control MC-33-l A - 24 - COLOUR CODING I n I D I - 25 R-R 3k R Y - Bk Bk w Bk - w--w R--R R--R UNDER In GY - GY AC90-IIOY P - Elk Y - 8k P--P TRANSFORMER NORMAL READINGS -26-
© Copyright 2024