Document 207185

F10
MOTORIZED FLOW CONTROL to 15 GPM
Function: Motor Driven Flow Control Cartridge for restrictive
type flow control, non-pressure compensated. Two wire
flying leads (std). Energize with 12 VDC to adjust flow.
Change polarity to open or close valve, cut 12 VDC power
to hold valve at desired setting. All that is required for basic
control is a DPDT switch.
M
M
Applications: Any circuit requiring electric remote control
of hydraulic flow such as remote flow control of a load
sense (pressure and flow compensated) pump. See
schematic on right.
Available Flow Ranges:
•
0 to 3 GPM Bidirectional
•
0 to 5 GPM Bidirectional
•
0 to 10 GPM Bidirectional
•
0 to 15 GPM Bidirectional
Operating Speeds:
•
1 second to 48 seconds for switch control
•
1 second for microprocessor controllers
•
Manual override std.
•
See motor specification sheet for details.
Electrical Characteristics:
•
12 VDC (9-15 VDC) std, 24 VDC (18-30 VDC)
optional
•
Momentary surge up to 2 amps for 12V, 3.75
amps for 24V
•
Fuse @ 2 or 4 amps depending on voltage.
Operating Pressure:
•
3000 psi maximum (consult factory for higher
pressures)
Cavity: 10-2 Industry Common Cavity (SAE #10, 7/8-14)
Temperature: -40 to 100 C
Installation: Torque at 35 ft-lbs
Costruction:
•
Cartridge body and spool: steel
•
Sealed Motor Container: Anodized Aluminum
•
Exposed Parts Plated
Available Operations:
•
Resistive Position Feedback
•
Electronic Controller Packages
•
Proportional Driver Interface
•
Line Manifolds
•
Consult factory for details
Select Flow Range:
0 to 3 GPM
0 to 5 GPM
0 to 10 GPM
0 to 15 GPM
F10 ** * ** ***** **
Select Operating Speed:
See motor Specification sheet on
Appendix page 1. Check for speed
and operating voltage (12 or 24)
Options:
_ _ Std 18'' flying leads
leave blank.
** See appendix page 2
for available options
2.00
7.50
1.125 HEX
7/8-14 THREAD
1.25
FLOW
FLOW
HOW TO ORDER
Manifold:
__
No Manifold, leave blank
10182 Standard body line, SAE #8
10182LS Body with Load Sense Port,
SAE #10
Consult Factory for Other
Options
Source Fluid Power - Phone: 952-368-3866 - Fax: 952-448-3392 - Sourcefp.com
Function: Two port motorized flow control package
with pressure compensating element.
Applications: Pressure compensated restrictive type
flow control typically used with pressure compensated
pumps and in circuits requiring constant flow under
varying load conditions.
Operating Pressure:
•
3000 psi maximum.
Flow Range:
•
•
•
•
0-3 GPM.
0-5 GPM.
0-10 GPM.
0-15 GPM.
Body material:
•
Anodized Aluminum.