RealLine Diagnostic Kits Pathogen Detection Cancer Mutation Detection Extraction Kits for Real Time PCR 2013 | 2014 INTRODUCTION Welcome to BIORON Diagnostics, a company devoted to sharing with you our expertise in the fast developing areas of Molecular Diagnostics. BIORON Diagnostics‘ expertise is based on in-depth knowledge of techniques in Molecular Biology and more than 10 years‘ experience gained by our sister company BIORON GmbH as a well-known producer of enzymes for molecular biology. In spite of the fantastic advances in the field of DNA analysis in the last 5 years, real time PCR remains the most requested technique for practical labs working in DNA/RNA diagnostics. The majority of BIORON Diagnostics kits for practical applications use real time PCR. We provide convenient techniques in diagnostics such as lyophilized, ready-to-use mixtures with a long shelf-life and the ability to be transported at room temperature. All kits are “open systems” which can be used basically with all current real time PCR machines. BIORON Diagnostics currently offers the most requested kits for viral / bacterial pathogens detections together with kits unique on the market. BIORON Diagnostics‘ new kits for Personalized Oncology (Companion Diagnostics) still have limited availability on the market from other suppliers and we are confident that our solutions will be appreciated by scientific and medical laboratories. Continuing our tradition in innovation, new products of BIORON Diagnostics are to be released after setting up the current catalog since quite a lot of products are in the last stages of development; some are in the R&D pipe-line. Please contact BIORON Diagnostics for updates, information on the new product in the fascinating area of Molecular Diagnostics. The diagnostic landscape is changing fast and BIORON Diagnostics team is trying to do everything to help you in setting up regular and new DNA-diagnostics techniques. The majority of BIORON Diagnostic Test Kits are CE-marked. We strive to have all our products CE-marked as speedily as possible and, as such, the CE label is clearly marked where obtained. Our current certification status of all products is clearly indicated in an overview table in this catalogue. If you have any questions relating to either our CE-marked products or those for RUO, our sales support team is always glad to help. Sincerely, BIORON Diagnostics Team www.bioron.de 3 TABLE OF CONTENTS Table of Contents INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. PCR KITS FOR PATHOGEN DETECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Sexually Transmitted Infections (STI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Candida albicans. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Chlamydia trachomatis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Gardnerella vaginalis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Mycoplasma genitalium. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Mycoplasma hominis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Neisseria gonorrhoeae. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Trichomonas vaginalis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Ureaplasma urealyticum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Simultaneous detection of two STI. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Candida albicans / Gardnerella vaginalis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Chlamydia trachomatis / Mycoplasma genitalium. . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Chlamydia trachomatis / Neisseria gonorrhoeae. . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Chlamydia trachomatis / Trichomonas vaginalis. . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Chlamydia trachomatis / Ureaplasma urealyticum . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Mycoplasma hominis / Mycoplasma genitalium . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Trichomonas vaginalis / Neisseria gonorrhoeae. . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Trichomonas vaginalis / Gardnerella vaginalis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Ureaplasma urealyticum / Ureaplasma parvum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Human Papilloma Virus (HPV). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 HPV 16 / 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 HPV 31 / 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 HPV 35 / 45. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 HPV High Risk, Genotype. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Mycobacterium tuberculosis (TB). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Human Herpesviridae . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Cytomegalovirus (CMV). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Eppstein-Barr Virus (EBV). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Human Simplex Virus HSV 1/HSV 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Human Herpes Virus HHV - 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Human Herpes Virus HHV - 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Varicella-Zoster Virus (VZV). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Tick Borne Infections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Anaplasma phagocytophilum / Ehrlichia muris and Ehrlichia chaffeensis. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 Borrelia burgdorferi s.l. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Tick born encephalitis virus (TBEV). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 4 TABLEINTRODUCTION OF CONTENTS Rubella . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Toxoplasma gondii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Parvovirus B19 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Helicobacter pylori . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 HumanImmunodeficiencyVirus(HIV) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Hepatitis C Virus (HCV). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Hepatitis B Virus (HBV). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 SUPPLEMENTARY PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Internal Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 Magnetic Rack for Extraction of Nucleic Acids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 2. KITS FOR CANCER-RELATED MUTATIONS ANALYSIS . . . . . . . . . . . . . . . . . . . . . . . . . . 45 BRAF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 EGFR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 KRAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Cancer Mutation DNA Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 3. KITS FOR EXTRACTION OF NUCLEIC ACIDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 RealLine Transportation Solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Extraction of DNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 RealLine DNA - Express . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 RealLine DNA - Extraction 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 RealLine DNA - Extraction 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 RealLine FFPE DNA Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 RealLine FFPE DNA Extraction Mag . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 Extraction of DNA and RNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 RealLine Extraction 100 and 100 (A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 RealLine Extraction 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 4. OVERVIEW TABLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Overview: purpose and use of the RealLine Extraction Kits . . . . . . . . . . . . . . . . . . . . . . 54 Cyclers tested with the RealLine Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 Available Samples of the RealLine Pathogen Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 CertificationStatus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 ALPHABETIC LIST OF PRODUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62 IMPRINT / CONDITIONS OF SALES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 www.bioron.de 5 PCR-KITS FOR PATHOGEN DETECTION INTRODUCTION PCR-KITS FOR PATHOGEN DETECTION RealLine Pathogen Kits Features: ● Ready to use master mix for detection of DNA or RNA in real time PCR ∞ ● Lyophilised Kits with highest stability ∞ ● One cycler protocol for the detection of a wide range of pathogens ∞ ● Internal Control for reliability and control of extraction and amplification included ∞ ● Carry over Protection in DNA detecting kits ∞ ● Compatible with the majority of real time PCR detection systems ∞ ● Storage at 2 - 8 °C for 12 months ∞ ● Transportation: at room temperature for up to 10 days, no cooling required! ∞ ● Simultaneous use of different assays, due to the uniform cycler protocol for DNA ∞ detection and nearly the same cycle protocol for RNA detection Different formats for different cyclers Str-format: The master mix is lyophilized in strips of 8 x 0.2 ml tubes. Just extract the nucleic acids (NA) and pipette into the tubes. This format is recommended for block cyclers e.g. BioRad CFX and IQ real-time PCR cycler. Fla-format: This format can be used for all types of real time PCR cyclers, carousel and microtiter plate based reactions. 10 reactions (50 µl each) are lyophilized in one vial and have to be diluted by the recovery solution, dispense the 2-fold concentrated master mix, add extracted NA and run the test. Uni-format: The Uni-format can also be used in nearly every cycler, as can be the Strformat.. One tube - one reaction (50 µl). The premix is filled in clear 0.2 ml single PCR tubes and can be used directly in blockcyclers or dispensed in capillaries, tubes or any kind of microtiter plates. 6 Explanations The formats Uni and Str contain the same complete lyophilised master mix. Therefore they may be used in nearly every cycler. For cycler types without the possibility to use 0.2 ml PCR tubes directly the master mix of the Uni- and Str-format tubes has to be transferred into the proprietary plates or capillaries. In this case usage of the Fla-format may offer the advantage of easier handling by a larger volume for dispensing. We are pleased to provide you with more information: [email protected] www.bioron.de PCR-KITS FOR PATHOGEN DETECTION PCR-KITS FOR PATHOGEN INTRODUCTION DETECTION 7 Candida albicans Product name Cat. no Format Pack size RealLine Candida albicans RealLine Candida albicans VBD4698 VBD4696 Str Fla 96 rcs 100 rcs Candida albicans is a fungus that grows both as yeast and as filamentous cells. Candida albicans infection is an important cause of morbidity and mortality of immunocompromised patients. Biofilms of Candida albicans may be formed on the surface of implanted medical devices. Hospital-acquired infections have become a major cause of health concern. Applications The RealLine Candida albicans kits detect Candida albicans DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Candida albicans infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Semen ● Prostatic fluid ● Urine Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Candida albicans DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla Fla Fla, Str Fla, Str SEXUALLY TRANSMITTED INFECTIONS (STI) PCR-KITS FOR PATHOGEN DETECTION SEXUALLY TRANSMITTED INFECTIONS (STI) Related Products Product name RealLine Candida / Gardnerella (Str-format) RealLine Candida / Gardnerella (Fla-format) RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBD0444 VBD0445 VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 96 rcs 100 rcs 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 8 Chlamydia trachomatis SEXUALLY TRANSMITTED INFECTIONS (STI) 0123 Product name Cat. no Format Pack size RealLine Chlamydia trachomatis RealLine Chlamydia trachomatis VBD1998 VBD1996 Str Fla 96 rcs 100 rcs 0123 Untreated, Chlamydia infections by Chlamydia trachomatis can cause serious reproductive and other health problems with both short-term and long-term consequences. In both sexes Chlamydia infection can cause proctitis, trachoma and infertility as well as prostatitis and epididymitis in men, and cervicitis, PID, ectopic pregnancy and acute/chronic pelvic pain in women. Chlamydia is known as the “Silent Epidemic” because in women it may not cause any symptoms in 75 % of cases, and can be latent for months or years before discovered. Applications Indications for Testing Sample Material Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats The RealLine Chlamydia trachomatis kits simultaneously detect plasmid and genomic DNA of Chlamydia trachomatis in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. ● Prevention and control of Chlamydia trachomatis infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. ● Scrapings of epithelial cells ● Semen ● Prostatic fluid ● Urine ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Chlamydia trachomatis DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION SEXUALLY TRANSMITTED INFECTIONS (STI) INTRODUCTION Related Products Product name Cat. No Pack size RealLine Chlamydia / Mycoplasma genitalium (Str-format) VBD0490 96 rcs RealLine Chlamydia / Mycoplasma genitalium (Fla-format) VBD0487 100 rcs RealLine Chlamydia / Neisseria (Str-format) VBD0457 96 rcs RealLine Chlamydia / Neisseria (Fla-format) VBD0458 100 rcs RealLine Chlamydia / Trichomonas (Str-format) VBD0498 96 rcs RealLine Chlamydia / Trichomonas (Fla-format) VBD0497 100 rcs RealLine Chlamydia / Ureaplasma urealyticum (Str-format) VBD0492 96 rcs RealLine Chlamydia / Ureaplasma urealyticum (Fla-format) VBD0491 100 rcs RealLine DNA – Express VBC8899 100 rcs RealLine DNA – Extraction 3 VBC8889 96 rcs RealLine Extraction 100 VBC8896 48 rcs RealLine Transport Solution VBC8894 100 rcs RealLine Internal Control VBC8881 250 rcs RealLine Magnetic Rack VBE9258 or VBE9291 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 9 PCR-KITS FOR PATHOGEN DETECTION SEXUALLY TRANSMITTED INFECTIONS (STI) Gardnerella vaginalis Product name Cat. no RealLine Gardnerella vaginalis RealLine Gardnerella vaginalis Format VBD4598 VBD4596 Pack size Str Fla 96 rcs 100 rcs Gardnerella vaginalis is a facultatively anaerobic Gram-variable rod that can cause bacterial vaginosis in some women as a result of a disruption in the normal vaginal microflora. Applications The RealLine Gardnerella vaginalis kits detect the Gardnerella vaginalis DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Gardnerella vaginalis infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Semen ● Prostatic fluid ● Urine Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Gardnerella vaginalis DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine Candida / Gardnerella (Str-format) RealLine Candida / Gardnerella (Fla-format) RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBD0444 VBD0445 VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 96 rcs 100 rcs 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 10 Mycoplasma genitalium Product name RealLine Mycoplasma genitalium RealLine Mycoplasma genitalium Cat. no Format VBD4396 VBD4394 Str Fla Pack size 96 rcs 100 rcs The Mycoplasma genitalium infection is associated with bacterial vaginosis. In the long term, this infection is suspected to cause pelvic inflammatory disease (PID). Applications The RealLine Mycoplasma genitalium kits detect the Mycoplasma genitalium DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Mycoplasma genitalium infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Saliva ● Urine ● Sperm Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Mycoplasma genitalium DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION SEXUALLY TRANSMITTED INFECTIONS (STI) INTRODUCTION Related Products Product name RealLine Mycoplasma genitalium / hominis (Str-format) RealLine Mycoplasma genitalium / hominis (Fla-format) RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBD0494 96 rcs VBD 0493 100 rcs VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 11 PCR-KITS FOR PATHOGEN DETECTION SEXUALLY TRANSMITTED INFECTIONS (STI) Mycoplasma hominis Product name Cat. no Format RealLine Mycoplasma hominis RealLine Mycoplasma hominis VBD4398 VBD4393 Str Fla Pack size 96 rcs 100 rcs Mycoplasma hominis is a bacterium that infects the mucous membranes of the urethra, cervix, throat and anus. Various symptoms of infection are known like urethritis (in men), discharge (both sexes), burning while urinating (both sexes), arthritis/reactive arthritis (mostly men), vaginal itching (women) as well as pain during intercourse (women). Applications The RealLine Mycoplasma hominis kits detect the Mycoplasma hominis DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Mycoplasma hominis infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Saliva ● Urine ● Sperm Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Mycoplasma hominis DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine Mycoplasma genitalium / hominis (Str-format) RealLine Mycoplasma genitalium / hominis (Fla-format) RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack for Extraction of Nucleic Acids Cat. no VBD0494 VBD0493 VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBC9291 Pack size 96 rcs 100 rcs 100 rcs 96 rcs 48 rcs 100 rcs 2 × 2 ml 1 unit We strongly recommend to use the RealLine DNA/RNA extraction along with the corresponding (or relevant) kits. If other DNA/RNA extraction systems are in use, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples for extraction and real time PCR control according to the protocol. 12 Neisseria gonorrhoeae Product name Cat. no RealLine Neisseria gonorrhoeae RealLine Neisseria gonorrhoeae VBD4498 VBD4496 Format Pack size Str Fla 96 rcs 100 rcs Neisseria gonorrhoeae are gram-negative motile bacteria and the causative agent of Gonorrhoeae, one of the most common sexually transmitted diseases. In women N. gonorrhoeae can lead to severe symptoms such as infertility and abortion. In men N. gonorrhoeae can lead to painful urethritis. Applications The RealLine Neisseria gonorrhoeae kits detect Neisseria gonorrhoeae DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Neisseria gonorrhoeae infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Semen ● Prostatic fluid ● Urine Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Neisseria gonorrhoeae DNA PCR-KITS FOR PATHOGEN DETECTION SEXUALLY TRANSMITTED INFECTIONS (STI) INTRODUCTION Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Related Products Product name RealLine Chlamydia / Neisseria (Str-format) RealLine Chlamydia / Neisseria (Fla-format) RealLine Trichomonas / Neisseria (Str-format) RealLine Trichomonas / Neisseria (Fla-format) RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBD0457 VBD0458 VBD0496 VBD0495 VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 96 rcs 100 rcs 96 rcs 100 rcs 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 13 PCR-KITS FOR PATHOGEN DETECTION INTRODUCTION SEXUALLY TRANSMITTED INFECTIONS (STI) Trichomonas vaginalis Product name Cat. no RealLine Trichomonas vaginalis RealLine Trichomonas vaginalis VBD2098 VBD2096 Format Pack size Str Fla 96 rcs 100 rcs Trichomonas vaginalis causes trichomoniasis, a disease that causes vaginal infections in women and urethritis in men. The transmission of trichomoniasis occurs through sexual intercourse and is one of the most common sexually transmitted diseases. Applications The RealLine Trichomonas vaginalis kits detect Trichomonas vaginalis genomic DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Trichomonas infection through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Semen ● Prostatic fluid ● Urine Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Trichomonas vaginalis DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine Chlamydia / Trichomonas RealLine Chlamydia / Trichomonas RealLine Trichomonas / Neisseria RealLine Trichomonas / Neisseria RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack (Str-format) (Fla-format) (Str-format) (Fla-format) Cat. no Pack size VBD0498 VBD0497 VBD0496 VBD0495 VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 96 rcs 100 rcs 96 rcs 100 rcs 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 14 Ureaplasma urealyticum Product name Cat. no Format Pack size RealLine Ureaplasma urealyticum RealLine Ureaplasma urealyticum VBD2298 VBD2296 Str Fla 96 rcs 100 rcs Ureaplasma urealyticum is part of the normal genital flora of both men and women. It is found in about 70% of sexually active humans. It had also been associated with a number of diseases in humans, including non-specific urethritis, infertility, chorioamnionitis, stillbirth, premature birth and in the perinatal period, pneumonia, bronchopulmonary dystroplasia as well as meningitis. Applications The RealLine Ureaplasma urealyticum kits detect Ureaplasma urealyticum DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Ureaplasma urealyticum infection through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Semen ● Prostatic fluid ● Urine Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Ureaplasma urealyticum DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION SEXUALLY TRANSMITTED INFECTIONS INTRODUCTION (STI) Related Products Product name RealLine Ureaplasma urealyticum / parvum (Str-format) RealLine Ureaplasma urealyticum / parvum (Fla-format) RealLine Chlamydia / Ureaplasma urealyticum (Str-format) RealLine Chlamydia / Ureaplasma urealyticum (Fla-format) RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBD2294 VBD2295 VBD2292 VBD2291 VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 96 rcs 100 rcs 96 rcs 100 rcs 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 15 PCR-KITS FOR PATHOGEN DETECTION SIMULTANEOUS DETECTION OF TWO STI Candida albicans / Gardnerella vaginalis Product name Cat. no Format Pack size RealLine Candida / Gardnerella RealLine Candida / Gardnerella VBD0444 VBD0445 Str Fla 96 rcs 100 rcs Candidiasis encompasses infections that range from superficial, such as oral thrush and vaginitis, to systemic and potentially life-threatening diseases. Candida albicans infections of the latter category are also referred to as candidemia and are usually confined to severely immunocompromised persons, such as cancer, transplant, and AIDS patients, as well as non-trauma emergency surgery patients. Gardnerella vaginalis is a facultatively anaerobic Gram-variable rod that can cause bacterial vaginosis in some women as a result of a disruption in the normal vaginal microflora. The RealLine Candida / Gardnerella kits detect and differentiate DNA from Candida Applications albicans and Gardnerella vaginalis in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Candida albicans and Gardnerella vaginalis infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Urine ● Saliva Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) Gardnerella vaginalis DNA ● ROX (575-602 nm) Candida albicans DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 16 Chlamydia trachomatis / Mycoplasma genitalium Product name RealLine Chlamydia / Mycoplasma genitalium RealLine Chlamydia / Mycoplasma genitalium Cat. no Format VBD0490 VBD0487 Str Fla Pack size 96 rcs 100 rcs Untreated Chlamydia infections by Chlamydia trachomatis can cause serious reproductive and other health problems with both short-term and long-term consequences. Mycoplasma genitalium is often asymptomatic, bacterial, sexually transmitted infection which bears some similarities to T. gonorrhoea and Chlamydia trichomonas. Because mycoplasma genitalium often occurs in association with other infections in both men and women, doctors still find it quite difficult to diagnose the condition on its own. Applications The RealLine Chlamydia / Mycoplasma genitalium kits detect and differentiate Chlamydia trachomatis plasmid and genomic DNA and Mycoplasma genitalium DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Chlamydia trachomatis and M. genitalium infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Saliva ● Urine Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) Chlamydia trachomatis DNA ● ROX (575-602 nm) Mycoplasma. genitalium DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION SIMULTANEOUS DETECTION OF TWO STI INTRODUCTION Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 17 PCR-KITS FOR PATHOGEN DETECTION INTRODUCTION DETECTION OF TWO STI SIMULTANEOUS Chlamydia trachomatis / Neisseria gonorrhoeae Product name Cat. no Format Pack size RealLine Chlamydia / Neisseria RealLine Chlamydia / Neisseria VBD0457 VBD0458 Str Fla 96 rcs 100 rcs Untreated, Chlamydia infections by Chlamydia trachomatis can cause serious reproductive and other health problems with both short-term and long-term consequences. In both sexes Chlamydia infection can cause proctitis, trachoma and infertility as well as prostatitis, epididymitis in men and cervicitis, PID, ectopic pregnancy and acute/chronic pelvic pain, in women. Neisseria gonorrhoeae are gram-negative motile bacteria and the causative agent of gonorrhea (clap), one of the most common sexually transferred disease. In women gonorrhea can lead to severe symptoms such as infertility and abortion. In men gonorrhoea can lead to painful urethritis. Applications RealLine Chlamydia / Neisseria kits detect and differentiate DNA from Chlamydia trachomatis and Neisseria gonorrhoeae in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Chlamydia trachomatis and Neisseria gonorrhoeae infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Semen ● Prostatic fluid ● Urine Real Time PCR Detection Channels ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) Chlamydia trachomatis DNA Neisseria gonorrhoeae DNA ● ROX (575-602 nm) Validated and Tested Cyclers Recommended Kit Formats ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 18 Chlamydia trachomatis / Trichomonas vaginalis Product name Cat. no Format RealLine Chlamydia / Trichomonas RealLine Chlamydia / Trichomonas VBD0498 VBD0497 Str Fla Pack size 96 rcs 100 rcs Untreated Chlamydia infections by Chlamydia trachomatis can cause serious reproductive and other health problems with both short-term and long-term consequences. Trichomonas vaginalis causes trichomoniasis, a disease that causes vaginal infections in women and urethritis in men. Applications Indications for Testing The RealLine Chlamydia / Trichomonas kits detect the Chlamydia trachomatis and the Trichomonas vaginalis DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. ● Prevention and control of Chlamydia trachomatis and Trichomonas vaginalis infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. ● Scrapings of epithelial cells ● Saliva ● Urine Sample Material Real Time PCR Detection Channels ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) Chlamydia trachomatis DNA Trichomonas vaginalis DNA ● ROX (575-602 nm) Validated and Tested Cyclers Recommended Kit Formats ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany PCR-KITS FOR PATHOGEN DETECTION SIMULTANEOUS DETECTION OF TWO STI INTRODUCTION Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 19 PCR-KITS FOR PATHOGEN DETECTION SIMULTANEOUS DETECTION OF TWO STI Chlamydia trachomatis / Ureaplasma urealyticum Product name Cat. no Format Pack size RealLine Chlamydia / Ureaplasma urealyticum RealLine Chlamydia / Ureaplasma urealyticum VBD0492 VBD0491 Str Fla 96 rcs 100 rcs Untreated Chlamydia infections by Chlamydia trachomatis can cause serious reproductive and other health problems with both short-term and long-term consequences. Ureaplasma urealyticum is associated with a number of diseases in humans, including non-specific urethritis, infertility, chorioamnionitis, stillbirth, premature birth and in the perinatal period, pneumonia, bronchopulmonary dystroplasia as well as meningitis. Applications The RealLine Chlamydia / Ureaplasma urealyticum kits detect and differentiate DNA from Chlamydia trachomatis and Ureaplasma urealyticum in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Chlamydia trachomatis and Ureaplasma urealyticum infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Semen ● Prostatic fluid ● Urine Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) Chlamydia trachomatis DNA ● ROX (575-602 nm) Ureaplasma urealyticum DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 20 Mycoplasma hominis / Mycoplasma genitalium Product name Cat. no Format RealLine Mycoplasma hominis / genitalium RealLine Mycoplasma hominis / genitalium VBD0494 VBD0493 Str Fla Pack size 96 rcs 100 rcs Mycoplasma genitalium, Mycoplasma hominis organisms are thought to be associated with non-gonococcal urethritis (NGU) and other genitourinary infections in clinical samples. Urethritis, an infection often acquired via sexual contact, is categorized into gonococcal urethritis or nongonococcal urethritis (NGU) depending on the presence or absence of Neisseria gonorrhoeae. In NGU, the infection is attributed to the pathogenic role of Chlamydia trachomatis, which has been detected in 30 to 40% of men with NGU, or to other pathogens, including mycoplasmas and ureaplasmas, in chlamydia-negative patients. Applications The RealLine Mycoplasma genitalium / hominis kits detect and differentiate Mycoplasma hominis and genitalium DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Mycoplasma genitalium and M.hominis infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Saliva ● Urine Real Time PCR Detection Channels ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) Mycoplasma hominis DNA Mycoplasma. Genitalium DNA ● ROX (575-602 nm) Validated and Tested Cyclers Recommended Kit Formats ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany PCR-KITS FOR PATHOGEN DETECTION SIMULTANEOUS DETECTION OF TWO STI INTRODUCTION Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 21 PCR-KITS FOR PATHOGEN DETECTION SIMULTANEOUS DETECTION OF TWO STI Trichomonas vaginalis / Neisseria gonorrhoeae Product name Cat. no Format Pack size RealLine Trichomonas / Neisseria RealLine Trichomonas / Neisseria VBD0496 VBD0495 Str Fla 96 rcs 100 rcs Trichomonas vaginalis causes trichomoniasis, a disease that causes vaginal infections in women and urethritis in men. The transmission of trichomoniasis occurs through sexual intercourse and is one of the most common sexually transmitted diseases. Neisseria gonorrhoeae are gram-negative motile bacteria and the causative agent of Gonorrhoeae, one of the most common sexually transmitted diseases. In women N. gonorrhoeae can lead to severe symptoms such as infertility and abortion. In men N. gonorrhoeae can lead to painful urethritis. The RealLine Trichomonas / Neisseria kits detect Trichomonas vaginalis and Neisseria gonorrhoeae DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Applications Indications for Testing Sample Material Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● Prevention and control of Trichomonas vaginalis and Neisseria gonorrhoeae infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. ● Scrapings of epithelial cells ● Semen ● Urine ● Prostatic fluid ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) Trichomonas vaginalis DNA ● ROX (575-602 nm) Neisseria gonorrhoeae DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 22 Trichomonas vaginalis / Gardnerella vaginalis Product name Cat. no Format Pack size RealLine Trichomonas / Gardnerella RealLine Trichomonas / Gardnerella VBD0477 VBD0478 Str Fla 96 rcs 100 rcs Trichomonas vaginalis causes trichomoniasis, a disease that causes vaginal infections in women and urethritis in men. The transmission of trichomoniasis occurs through sexual intercourse and is one of the most common sexually transmitted diseases. Gardnerella vaginalis is a facultatively anaerobic Gram-variable rod that can cause bacterial vaginosis in some women as a result of a disruption in the normal vaginal microflora. Trichomonas vaginalis and Gardnerella vaginalis have similar clinical presentations and can cause a frothy gray or yellow-green vaginal discharge, pruritus, and produce a positive "whiff-test." With this assay the both pathogens can be differentiated and especially treated The RealLine Trichomonas / Gardnerella kits detect Trichomonas vaginalis and Gardnerella vaginalis DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Applications Indications for Testing Sample Material Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● Prevention and control of Trichomonas vaginalis and Neisseria gonorrhoeae infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. ● Scrapings of epithelial cells ● Semen ● Urine ● Prostatic fluid ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) Gardnerella vaginalis DNA ● ROX (575-602 nm) Trichomonas vaginalis DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION SIMULTANEOUS DETECTION INTRODUCTION OF TWO STI Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 23 PCR-KITS FOR PATHOGEN DETECTION SIMULTANEOUS DETECTION OF TWO STI Ureaplasma urealyticum / Ureaplasma parvum Product name Cat. no Format Pack size RealLine Ureaplasma urealyticum/ parvum RealLine Ureaplasma urealyticum/ parvum VBD2294 VBD2295 Str Fla 96 rcs 100 rcs Ureaplasma parvum is generally the most common species detected in various clinical specimens. Ureaplasma urealyticum is apparently more pathogenic in conditions such as male urethritis. Ureaplasma urealyticum is part of the normal genital flora of both men and women. In about 70% of sexually active humans it is found and is described to be associated with a number of diseases in humans, including non-specific urethritis (NSU), infertility, chorioamnionitis, stillbirth, premature birth and others. Applications The RealLine Ureaplasma urealyticum / parvum kits detect the Ureaplasma urealyticum and Ureaplasma parvum DNA in clinical samples by real time PCR and in different channels. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and contro of Ureaplasma urealyticum / U. parvum infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Semen ● Urine ● Prostatic fluid Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) Ureaplasma urealyticum DNA ● ROX (575-602 nm) Ureaplasma parvum DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 24 Human Papilloma Virus (HPV) - High Carcinogenic Risk Types Product name RealLine HPV 16 / 18 RealLine HPV 16 / 18 RealLine HPV 31 / 33 RealLine HPV 31 / 33 RealLine HPV 35 / 45 RealLine HPV 35 / 45 Cat. no Format Pack size VBD8473 VBD8474 VBD8471 VBD8480 VBD8469 VBD8477 Str Fla Str Fla Str Fla 96 rcs 100 rcs 96 rcs 100 rcs 96 rcs 100 rcs Human Papilloma Viruses HPV are DNA-Viruses of which more than 100 different types are known. While the majority of HPVs cause no symptoms, some can cause low severe symptoms like warts and a few are know to cause cancer, especially cervical cancer in women. The HPV types that are more likely to lead to the development of cancer are referred to as “high cancer-risk” types HPV. Applications The RealLine HPV Kits are designed for sensitive direct detection of HPV high cancer risk genotypes in clinical samples by real time PCR. The kits are designed for in vitro diagnostics, for qualitative or quantitative detection. The detection of the types of Papilloma viruses are dependent on the different kits. In double kits the named HPV types and the internal control are detected. Indications for Testing ● Assess risk of cervical cancer in women of 30 years and above as an adjunct to cytology results ● Risk analysis of cervical cancer in women who have an ASC-US cervical cytology results ● Estimation of the impact of HPV vaccination on risk of acquisition and on distribution of individual HPV types in a population Sample Material ● Blood serum, plasma ● Scrapings of epithelial cells ● Urine Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) HPV genotypes ● ROX (575-602 nm) HPV genotypes ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION HUMAN PAPILLOMA VIRUS (HPV) INTRODUCTION Related Products Product name Cat. no Pack size RealLine DNA – Express VBC8899 100 rcs RealLine DNA – Extraction 3 VBC8889 96 rcs RealLine Extraction 100 VBC8896 48 rcs RealLine Transport Solution VBC8894 100 rcs RealLine Internal Control VBC8881 250 rcs RealLine Magnetic Rack VBE9258 or VBE9291 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 25 PCR-KITS FOR PATHOGEN DETECTION HUMAN PAPILLOMA VIRUS (HPV) Human Papilloma Virus (HPV) – High Cancer Risk Types – Genotyping Product name Cat. no Format Pack size RealLine HPV High Risk, Genotype RealLine HPV High Risk, Genotype, quantitative RealLine HPV High Risk, Genotype VBD8479 VBD8478 VBD8482 Str Str Fla 96 rcs 96 rcs 100 rcs High carcinogenic risk types of Human Papilloma Viruses HPV can lead to invasive cervical cancer in women. One or more of this types are detected in the tumor cells. Applications The genotyping RealLine HPV Kits are designed for sensitive direct detection of HPV high carcinogenic risk genotypes in clinical samples by real time PCR. The IVD kits are designed for qualitative or quantitative detection. In the genotyping kits following HPV types can be detected: 6, 11, 16, 18, 31, 33, 35, 45, 51, 52, 56, 58. Indications for Testing ● Assess risk of cervical cancer in women of 30 years and above as an adjunct to cytology results ● Risk analysis of cervical cancer in women who have an ASC-US cervical cytology results ● Estimation of the impact of HPV vaccination on risk of acquisition and on distribution of individual HPV types in a population Sample Material Real Time PCR Detection Channels ● Blood serum, plasma ● Scrapings of epithelial cells ● Urine ● Cy5 (647-667 nm) Internal Control IC ● FAM (495-520 nm) HPV genotypes DNA ● HEX (535-554 nm) HPV genotypes DNA ● ROX (575-602 nm) HPV genotypes DNA HMBS Gene in quantitative assay Validated and Tested Cyclers Recommended Kit Formats ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Related Products Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Product name Cat. no Pack size RealLine DNA – Express VBC8899 100 rcs RealLine DNA – Extraction 3 VBC8889 96 rcs RealLine Extraction 100 VBC8896 48 rcs RealLine Transport Solution VBC8894 100 rcs RealLine Internal Control VBC8881 250 rcs RealLine Magnetic Rack VBE9258 or VBE9291 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 26 Mycobacterium tuberculosis Product name RealLine Mycobacterium tuberculosis incl. Extraction RealLine Mycobacterium tuberculosis Cat. no Format Pack size VBD2398 Uni 48 rcs VBD2399 Str 96 rcs Tuberculosis, also named MBT, TBC or TB, is a world-wide, common and often lethal infectious disease caused by Mycobacterium tuberculosis. The number of new infections is still increasing. Tuberculosis usually attacks the lungs, but also other parts of the body can be affected. The infection is spread by droplet infection and causes symptoms like chronic coughing with blood-tinged sputum, fever, nocturnal sweats and weight loss. Applications Indications for Testing Sample Material Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats The RealLine Mycobacterium tuberculosis kit is designed to detect DNA of Mycobacterium tuberculosis complex isolated from clinical specimens using real time PCR method with fluorescent detection of an amplified product. ● Detection of Tuberculosis from clinical specimen ● Blood serum, plasma ● Whole blood ● Biopsy material, liquor ● Urine ● Epithelial cells specimens, cultures of microorganisms, swabs of environmental objects ● Bronchopulmonary lavage ● Sputum ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Tuberculosis-complex DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Uni, Str Uni, Str Uni, Str Uni, Str Uni, Str Uni, Str Uni, Str PCR-KITS FOR PATHOGEN DETECTION MYCOBACTERIUM TUBERCULOSIS (TB) INTRODUCTION Related Products Product name RealLine Transport Solution RealLine Extraction 100 RealLine Internal Control RealLine Magnetic Rack Cat. no VBC8894 VBC8896 VBC8881 VBE9258 or VBE9291 Pack size 100 rcs 48 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 27 PCR-KITS FOR PATHOGEN DETECTION HUMAN HERPESVIRIDAE Cytomegalovirus CMV 0123 0123 0123 Product name Cat. no Format RealLine CMV RealLine CMV VBD1598 VBD1596 Str Fla Pack size 96 rcs 100 rcs CMV infection is important for certain high-risk groups: patients who are immunocompromised e.g. patients with HIV, organ transplant recipients, persons with leukemia, foeti and neonatal infants. CMV is one of the TORCH infections which leads to congenital abnormalities and therefore an early diagnosis of CMV especially for pregnant women and women of reproductive age is extremely important. Applications The RealLine CMV kits are designed for the sensitive direct detection of CMV DNA in clinical samples by real time PCR. The kits are designed for in vitro Diagnostics and for qualitative detection. Indications for Testing ● Identification of active and latent infections. ● Estimation of acute infection appearance risk. Sample Material ● Scrapings of epithelial cells ● Saliva ● Semen ● Prostatic fluid ● Urine ● Whole blood, serum or plasma ● Leukocytic mass Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) CMV DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 2 RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no VBC8899 VBC8897 VBC8889 VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 Pack size 100 rcs 96 rcs 96 rcs 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 28 Eppstein-Barr-Virus EBV Product name Cat. no Format RealLine EBV RealLine EBV VBD2198 VBD2196 Str Fla Pack size 96 rcs 100 rcs EBV is quite common in population leaving the majority of individuals with a lifelong silent infection. Many children become infected with EBV asymptomatically. The virus is the causative agent of infectious mononucleosis. EBV is associated with the development of two epithelial tumors, nasopharyngeal carcinoma and oral hairy leukoplakia. Applications The RealLine EBV kits are designed for sensitive direct detection of EBV DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide for qualitative detection. Indications for Testing ● Identification of active and latent infections ● Epidemiological studies Sample Material ● Whole blood ● Blood serum, plasma ● Saliva ● Swabs from the nasal mucosa ● Scrapings of the epithelial cells Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) EBV DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION HUMAN HERPESVIRIDAE INTRODUCTION Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 2 RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8897 VBC8889 VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 96 rcs 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 29 PCR-KITS FOR PATHOGEN DETECTION HUMAN HERPESVIRIDAE Herpes Simplex Virus HSV-1/ HSV-2 Product name Cat. no Format Pack size RealLine HSV-1/ HSV-2 RealLine HSV-1/ HSV-2 VBD2195 VBD2197 Str Fla 96 rcs 100 rcs HSV-1 is an oral form of herpes typically affecting the mouth and surrounding areas on the face. In addition, HSV1 can cause encephalitis, keratoconjunctivitis, stomatitis and skin infections. Transmission generally occurs through saliva and rarely through sex contact. HSV-2 causes most cases of genital herpes as well as the neurological manifestations such as meningitis and radiculitis. Pregnant women and infants are risk groups for HSV infections since when infants do contract neonatal herpes, they may suffer serious neurological damage, mental retardation or death. In addition HSV-2 is known to increase a person’s risk of contracting HIV. Applications Indications for Testing Sample Material Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats The RealLine HSV-1 / HSV-2 kit is designed for in vitro diagnostics and the detection and differentiation of HSV-1 and HSV-2 DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provides qualitative detection. ● The RealLine HSV-1 / HSV-2 kits are used for direct detection and genotyping of HSV-1 and HSV- 2 infection in clinical specimens. ● Scrapings of epithelial cells ● Saliva ● Semen ● Prostatic fluid ● Urine ● Whole blood, serum or plasma ● Leukocytic mass ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) HSV-1 DNA ● ROX (575-602 nm) HSV-2 DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 2 RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8897 VBC8889 VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 96 rcs 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 30 Human Herpes Virus HHV-6 Product name Cat. no Format RealLine HHV-6 RealLine HHV-6 VBD2150 VBD2151 Str Fla Pack size 48 rcs 50 rcs HHV-6 infections can occur early in life asymptomatically with lifelong persistence. Primary infection with HHV-6 causes roseola infantum, a common childhood disease that resolves spontaneously. The virus remains latent in lymphocytes and monocytes and persists at low levels in cells and tissues. It can reactivate at a later date, and is believed to contribute to diseases of the bone marrow and/or central nervous system in some patients, including mononucleosis, illness with fever, lymphadenopathy, hepatitis, fatal encephalitis, chronic fatigue syndrome, and possibly multiple sclerosis. Transmission of HHV-6 is believed to occur as a result of exposure to saliva. Applications The RealLine HHV-6 kits are designed for sensitive direct detection of HHV-6 DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and a qualitative detection of HHV-6. Indications for Testing ● Detection of acute reactivation of HHV-8 infection in clinical samples of immunocompromised individuals ● Detection of acute reactivation of HHV-6 infection in transplant patients ● HHV-6 detection in the serum during primary roseola infection in pediatric populations Sample Material ● Scrapings of epithelial cells ● Saliva ● Semen ● Prostatic fluid ● Urine ● Whole blood, serum or plasma ● Leukocytic mass Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) HHV-6 DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION HUMAN HERPESVIRIDAE INTRODUCTION Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 2 RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8897 VBC8889 VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 96 rcs 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 31 PCR-KITS FOR PATHOGEN DETECTION HUMAN HERPESVIRIDAE Human Herpes Virus HHV-8 Product name Cat. no Format Pack size RealLine HHV-8 RealLine HHV-8 VBD2148 VBD2149 Str Fla 48 rcs 50 rcs HHV-8 is a cancer-causing herpes virus. Most people infected with HHV-8 do not know about the infection. After infection, the virus enters the lymphocytes where it remains latent. HHV-8 mostly causes disease in immunocompromised individuals. HHV-8 can lead to Kaposi‘s sarcoma, lymphoma, multicentric Castleman‘s disease, a non Hodgkin‘s Disease and hypergammaglobulinemia. Applications Indications for Testing Sample Material Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats The RealLine HHV-8 kits are designed for sensitive direct detection of HHV-8 DNA in clinical samples by real time PCR. The kits are designed for In vitro diagnostics and qualitative detection of Human-Herpes-Virus 8. ● Detection of acute reactivation of HHV-8 infection in clinical samples of immunocompromised individuals ● Scrapings of epithelial cells ● Saliva ● Semen ● Prostatic fluid ● Urine ● Whole blood, serum or plasma ● Leukocytic mass ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) HHV-8 DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 2 RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8897 VBC8889 VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 96 rcs 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 32 Varicella Zoster Virus VZV Product name Cat. no Format Pack size RealLine VZV RealLine VZV VBD2185 VBD2187 Str Fla 48 rcs 50 rcs Primary VZV infection causes chicken-pox in children and serious complications of shingles include postherpetic neuralgia, zoster multiplex, myelitis, herpes ophthalmicus, or zoster sine herpete in adults, however rarely in children. In about 10 – 20 % of the cases, VZV reactivates later in life. It most commonly occurs in people over age 50, and in those with a weakened immune system. Applications The RealLine VZV kit is designed for sensitive direct detection of VZV DNA in clinical samples by real time PCR. The kits are designed for In vitro diagnostics and provide qualitative detection. Indications for Testing ● Identification of active and latent infections. ● Detection of primary VZV infection or acute reactivation in pregnant woman or those considering pregnancy. ● Detection of primary VZV infection in health workers prior to varicella vaccination or after exposure to VZV. Sample Material ● Scrapings of epithelial cells ● Saliva ● Semen ● Prostatic fluid ● Urine ● Whole blood, serum or plasma ● Leukocytic mass Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) VZV DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION HUMAN HERPESVIRIDAE INTRODUCTION Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 2 RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8897 VBC8889 VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 96 rcs 48 rcs 48 rcs 100 rcs 2 × 2 ml 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 33 PCR-KITS FOR PATHOGEN DETECTION TICK BORNE INFECTIONS Anaplasma phagocytophilium, Ehrlichia muris and E. chaffeensis Product name RealLine Anaplasma / Ehrlichia RealLine Anaplasma / Ehrlichia Cat. no Format Pack size VBD5398 VBD5399 Str Fla 48 rcs 50 rcs Ehrlichiosis or human granulocytic anaplasmosis are diseases which can be caused by Anaplasma phagocytophilum, Ehrlichia chaffeensis or Ehrlichia muris. Humans and other mammals are infected by bites of ticks. If the disease is symptomatic it can come to flue-like symptoms up to serious symptoms like Meningoencepahiltis especially in immunosupressed patients. Applications The RealLine Anaplasma / Ehrlichia kits detect and differentiate DNA of Anaplasma phagocytophilium and of Ehrlichia muris and E.chaffeensis in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Persons with a risk and clinical symptoms of a Ehrlichiosis or Anaplasmosis Sample Material ● Blood serum, plasma ● Cerebrospinal fluid ● Tick suspension samples Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) Anaplasma phagocytophilium DNA ● ROX (575-602 nm) Ehrlichia muris and chaffeensis DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Extraction 2 RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no VBC8897 VBC8889 VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 Pack size 96 rcs 96 rcs 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 34 Borrelia burgdorferi s.l. Product name RealLine Borrelia burgdorferi s.l. RealLine Borrelia burgdorferi s.l. Cat. no Format Pack size VBD1498 VBD1499 Str Fla 48 rcs 50 rcs Lyme disease or borreliosis is considered to be one of the fastest spreading illnesses in the world. Gram negative spirochetal bacteria from the genus Borrelia, collectively known as the Borrelia burgdorferi sensu lato group, cause Lyme disease. Applications Indications for Testing Sample Material Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats The RealLine Borrelia burgdorferi sensu lato kits detect the B. burgdorferi sensu lato group (Borrelia afzelii, Borrelia garinii, Borrelia burgdorferi sensu stricto) DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. ● Persons with a risk for Lyme disease and ● Patients with clinical symptoms for Borreliosis ● Blood serum, plasma ● Cerebrospinal fluid ● Tick suspension samples ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Borrelia burgdorferi s.l DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION TICK BORNE INFECTIONS INTRODUCTION Related Products Product name RealLine DNA – Extraction 2 RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no VBC8897 VBC8889 VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 Pack size 96 rcs 96 rcs 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 35 PCR-KITS FOR PATHOGEN DETECTION TICK BORNE INFECTIONS Tick Borne Encephalitis Virus TBEV Product name Cat. no Format Pack size RealLine TBEV RealLine TBEV VBD1198 VBD1199 Str Fla 48 rcs 50 rcs TBEV is endemic in an area ranging from northern China and Japan through far-eastern Russia to Europe. TBEV is transmitted by the bite of infected ticks, or (rarely) through the non-pasteurized milk of infected cows, sheep and goats. TBEV is a viral infectious disease involving the central nervous system (CNS). The disease is incurable once manifested, so there is no specific drug therapy for TBEV. Applications The RealLine TBEV kit is designed for sensitive direct detection of TBEV RNA in clinical samples by one-step real time RT-PCR. The kits are designed for in vitro diagnostics and provides qualitative detection. Indications for Testing ● Patients with typical CNS symptoms ● Tick bite Sample Material ● Blood serum, plasma ● Cerebrospinal fluid ● Tick suspension samples Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) TBEV RNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 Pack size 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 36 Rubella 0123 0123 0123 Product name Cat. no Format Pack size RealLine Rubella RealLine Rubella VBD2598 VBD2596 Str Fla 48 rcs 50 rcs Rubella is a common childhood infection usually with minimal systemic upset although transient arthropathy may occur in adults. The primary medical danger of Rubella is the infection of pregnant women because it can cause congenital rubella syndrome (CRS) in the developing fetus which entails a range of incurable serious illnesses. Applications Indications for Testing Sample Material Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats The RealLine Rubella kits are designed for sensitive direct detection of Rubella RNA in clinical samples by one-step real time PCR. The kits are designed for qualitative in vitro diagnostics. ● Detection of Rubella infection in pregnant woman or those considering pregnancy. ● Analysis prior to vaccination. ● Follow up after exposure to Rubella infection. ● blood serum ● plasma ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Rubella RNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION RUBELLA INTRODUCTION Related Products Product name RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 Pack size 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 37 PCR-KITS FOR PATHOGEN DETECTION TOXOPLASMA GONDII Toxoplasma gondii 0123 Product name Cat. no Format Pack size RealLine Toxoplasma gondii VBD1798 Str 48 rcs RealLine Toxoplasma gondii VBD1796 Fla 100 rcs Toxoplasma gondii is a species of parasitic protozoa of the genus Toxoplasma. Early and definitive diagnosis is very important for recently infected pregnant women in order to prevent infection of the fetus by appropriate treatment as well as for persons with severely weakened immune systems. Applications The RealLine Toxoplasma gondii detection by real time PCR is based on the amplification of DNA corresponding to a specific region of the pathogen genome. Indications for Testing ● Detection of acute reactivation of T. gondii infection in clinical samples of immunocompromised individuals. ● Test of pregnant women with a risk of T. gondii infection. Sample Material ● blood serum ● plasma Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Toxoplasma gondii DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Extraction 2 RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no VBC8897 VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 Pack size 96 rcs 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We str ecommend usi he RealLine DNA/RNA extraction al ith the RealLine pat ection kits. If other DNA/RNA extracti ems are used, please order the RealLine Internal Control IC #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 38 Parvovirus B19 Product name Cat. no Format Pack size RealLine Parvovirus B19 RealLine Parvovirus B19 VBD2801 VBD2802 Str Fla 96 rcs 100 rcs Parvovirus B19 or just B19, is a small single-stranded DNA virus of the parvovirus family. It can cause several diseases such as “the fifth disease (erythema infectiosum)” in children. Especially in girls and young women the disease can develop and affect the joints, known as acute symmetric polyarthropathy. Parvovirus B19 replicates only in erythroblasts, the progenitors of red blood cells (erythrocytes) in the bone marrow. Therefore, the infection triggers in each patient a temporary anemia which can cause complications and even death in immunocompromised individuals. During pregnancy B19 can lead to spontaneous abortions and other complications such as fetal hydrops, which can seriously harm the fetus if not recognized. Applications The RealLine Parvovirus B19 kits detect Parvovirus B19 DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Prevention and control of Parvovirus B19 infections through early detection and treatment of asymptomatic infection. ● Reduction of onward transmission to sexual partners. ● Prevention of the consequences of untreated infection. Sample Material ● Scrapings of epithelial cells ● Semen ● Prostatic fluid ● Urine Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Parvovirus B19 DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str PCR-KITS FOR PATHOGEN DETECTION PARVOVIRUS B19 INTRODUCTION Related Products Product name RealLine DNA – Express RealLine DNA – Extraction 2 RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8899 VBC8897 VBC8889 VBC8896 VBC8894 VBC8881 VBE9258 or VBE9291 100 rcs 96 rcs 96 rcs 48 rcs 100 rcs 250 rcs 1 unit We str ecommend usi he RealLine DNA/RNA extraction al ith the RealLine pat ection kits. If other DNA/RNA extractio stems are used, please order the RealLine Internal Control IC #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 39 PCR-KITS FOR PATHOGEN DETECTION HELICOBACTER PYLORI Helicobacter pylori Product name Cat. no Format Pack size RealLine Helicobacter pylori RealLine Helicobacter pylori VBD3798 VBD3796 Str Fla 48 rcs 50 rcs Helicobacter pylori is a gram-negative, microaerophilic bacterium found in the stomach. The most people infected with H.pylori show no symptoms, but an acute infection may appear as an acute gastritis with abdominal pain (stomach ache) or nausea. Where an acute gastritis cause a chronic gastritis, the symptoms, are often those of non-ulcer dyspepsia: stomach pains, nausea, bloating, belching, and sometimes vomiting or black stool. The presence of H.pylori is a risk factor for gastric cancer. Applications The RealLine Helicobacter pylori kits detect Helicobacter pylori DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative detection. Indications for Testing ● Initial diagnostics of H. pylori ● Confirmation of the cure Sample Material ● Stomach tissue samples Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● ROX (575-602 nm) Helicobacter pylori DNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Fla Fla Fla Str, Fla, Fla Fla, Str Fla, Str Related Products Product name RealLine DNA – Extraction 2 RealLine Extraction 100 RealLine Transport Solution RealLine Magnetic Rack Cat. no VBC8897 VBC8896 VBC8894 VBE9258 or VBE9291 Pack size 96 rcs 48 rcs 100 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please use the special “RealLine Helicobacter Internal Control” which is provided with the kit and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 40 Human Immunodeficiency Virus (HIV) Product name RealLine HIV qualitative RealLine HIV quantitative RealLine HIV qualitative incl. Extraction RealLine HIV quantitative incl. Extraction Cat. no Format VBD0196 VBD0195 VBD0198 VBD0199 Str Str Uni Uni Pack size 96 rcs 96 tcs 48 rcs 48 rcs Human immunodeficiency virus (HIV) is a member of the genus Lentivirus, part of the family of Retroviridae, that causes acquired immunodeficiency syndrome (AIDS). Since its discovery in 1981 AIDS has killed more than 25 million people. Applications The RealLine HIV kits are designed to direct detection and quantification of HIV RNA in clinical samples by real time RT-PCR. The kits are designed for in vitro diagnostics and provides qualitative or quantitative detection. Indications for Testing RealLine qualitative detection ● Screening of plasma specimens from blood donors. ● Research on primary HIV infection. ● Identification of individuals with high viral replication (to identify highly contagious individuals). ● Monitoring of mother-to-child transmission. Sample Material RealLine quantitative detection ● Assessing disease progression. ● Monitoring of the effect of anti-retroviral treatment. ● Determination of the level of viral load in the blood. ● Blood serum, plasma ● FAM (495-520 nm) Internal Control IC (in quantitative kits: Standard CS1) ● ROX (575-602 nm) HIV RNA (in quantitative kits: Standard CS2) ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Uni Uni, Str Uni, Str Str, Uni Uni Uni, Str Uni, Str Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats PCR-KITS FOR PATHOGEN DETECTION HUMAN IMMUNODEFICIENCY VIRUS (HIV) INTRODUCTION Related Products Product name RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 41 PCR-KITS FOR PATHOGEN DETECTION HEPATITIS C VIRUS (HCV) Hepatitis C Virus (HCV) Product name RealLine HCV Genotype qualitative RealLine HCV Genotype quantitative RealLine HCV qualitative RealLine HCV quantitative RealLine HCV qualitative incl. extraction RealLine HCV quantitative incl. extraction Cat. no Format Pack size VBD0793 VBD0797 VBD0795 VBD0794 VBD0798 VBD0799 Uni Str Str Str Uni Uni 48 rcs 48 rcs 96 rcs 96 rcs 48 rcs 48 rcs Hepatitis C virus (HCV) is a public health concern worldwide and a major cause of chronic liver inflammation, cirrhosis and hepatocellular carcinoma. It is transmitted parenterally, showing a high incidence in hemophiliacs, hemodialysis patients, drug users using contaminated syringes, and patients with post-transfusion hepatitis. Applications Indications for Testing Qualitative and quantitative RealLine HCV kits are designed for laboratory diagnostics or high-throughput analysis of HCV RNA by real time PCR. The RealLine HCV Genotype (quantitative) Kit is a reagent kit for the detection, quantitative determination and differentiation of HCV genotypes 1, 2 and 3 RNA. ● Protection of the blood supply ● Diagnostics of infection with HCV (HCV RNA is detectable by RT-PCR 1-2 weeks after exposure). ● Determination whether an individual is a chronic carrier. ● Evaluation of the effect of anti-HCV therapies (interferon (IFN) monotherapy or in combination with ribavirin). ● Determination of the viral load in an individual who is considering therapy. ● Observation of the rate of decline of viral load during the first few weeks of treatment as a predictor of complete response. ● Blood serum, plasma Sample Material Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats ● FAM (495-520 nm) Internal Control IC ● HEX (535-554 nm) HCV genotypes RNA ● ROX (575-602 nm) HCV genotypes RNA ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Uni Uni, Str Uni, Str Str, Uni Uni Uni, Str Uni, Str Related Products Product name RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no Pack size VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. 42 Hepatitis B Virus (HBV) Product name RealLine HBV qualitative RealLine HBV quantitative RealLine HBV qualitative incl. extraction RealLine HBV quantitative incl. extraction Cat. no Format VBD0596 VBD0595 VBD0598 VBD0599 Str Str Uni Uni Pack size 96 rcs 96 rcs 48 rcs 48 rcs HBV is a partially double-stranded DNA virus of the Hepadnaviridae family that causes acute and chronic liver disease with a very high risk of death from liver cirrhosis and cancer. Worldwide an estimated 2 billion people have been infected with the hepatitis B virus(HBV) and more than 350 million suffer chronic consequences from the disease. Applications The RealLine HBV kits detect the different genotypes of HBV DNA in clinical samples by real time PCR. The kits are designed for in vitro diagnostics and provide qualitative or quantitative detection. Indications for Testing ● Screening of plasma specimens from blood donors. ● Perform screens of plasma specimens from blood donors. ● Identification of individuals with high viral replication. ● Determination if someone is a HBV chronic carrier. ● To detect previous infection (with subsequent immunity). ● Analysis of small subgroups of patients who are HBeAg negative but carry the HBV virion. ● Assess disease progression. ● Monitoring the efficacy of antiviral therapy. ● Detect the occurrence of drug-resistant mutants. Sample Material ● Blood serum, plasma ● FAM (495-520 nm) Internal Control IC (in quantitative kits: Standard CS1) ● ROX (575-602 nm) HBV DNA (in quantitative kits: Standard CS2) ● Bio-Rad CFX96™, iQ™ (Bio-Rad, USA) ® ● Rotor-Gene 3000/6000 (QIAGEN, Germany) ● Eco Cycler (Illumina, USA) ● DTPrime, DTLite (DNA-Technology, Russia) ® ● LightCycler 480 and 2.0 (Roche, Switzerland) ● AB 7300/7500 (Applied Biosystems, USA) ● Mastercycler (Eppendorf, Germany Str, Uni Uni, Str Uni, Str Str, Uni Uni Uni, Str Uni, Str Real Time PCR Detection Channels Validated and Tested Cyclers Recommended Kit Formats PCR-KITS FOR PATHOGEN DETECTION HEPATITISINTRODUCTION B VIRUS (HBV) Related Products Product name RealLine Extraction 100 RealLine Extraction 1000 RealLine Transport Solution RealLine Internal Control RealLine Magnetic Rack Cat. no VBC8896 VBC8895 VBC8894 VBC8881 VBE9258 or VBE9291 Pack size 48 rcs 48 rcs 100 rcs 250 rcs 1 unit We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, please order the RealLine Internal Control (IC) #VBC8881 and add it to the samples as well as the controls prior to DNA/RNA extraction procedure as indicated in the protocol. www.bioron.de 43 PCR-KITS FOR PATHOGEN DETECTION SUPPLEMENTARY PRODUCTS Internal Control for RealLine Pathogen Kits Product name Cat. no Pack size RealLine Internal Control VBC8881 250 rcs An Internal Control, IC, should be included in each sample in order to verify that all procedures starting from the extraction of DNA or RNA to the detection and analysis are functioning correctly. Normally Internal Control is supplied together with RealLine DNA/RNA extraction kits. We strongly recommend using the RealLine DNA/RNA extraction along with the RealLine pathogen detection kits. If other DNA/RNA extraction systems are used, the IC should be added to the samples and to the controls prior to DNA/RNA extraction procedure as indicated in the protocol. Target DNA/RNA should be isolated jointly with Internal control IC for the extraction and real time PCR efficiency control in each sample. Applications RealLine Magnetic Rack Product name RealLine Magnetic Rack, exchangeable plastic covers Realline Magnetic Rack, fix plastic cover Cat. no Pack size VBE9291 VBE9258 1 unit 1 unit There are two magnetic racks available for the simple and fast magnetic spheres based DNA/RNA extraction procedures: - with exchangeable plastic covers for prevention of contamination - fix autoclavable plastic One magnetic rack enables to perform 12 to 16 simultaneous DNA/RNA extractions with magnetic spheres based extraction systems. Related Products Product name RealLine DNA – Extraction 3 RealLine Extraction 100 RealLine Extraction 1000 44 Cat. no Pack size VBC8889 VBC8896 VBC8895 96 rcs 48 rcs 48 rcs Kits for Cancer Mutation Analysis The RealLine Oncoline kits are a new generation of cancer mutations detection kits based on AlleleSpecific real time PCR detection and fast analysis. BRAF BRAF, a serine-threonine kinase, is one members of the RAF protein kinase family. Activating mutations in BRAF were described in cases of melanoma, papillary thyroid cancer, testicular, ovarian and colon cancers. Most common (~80%) of these somatic mutations is a missense mutation T1799A within the kinase domain of the BRAF that leads to change of Valine (Val) to Glutamic acid (Glu) at position 600 (V600E). The selective inhibitor of BRAF – Zelboraf (Vemurafenib/PLX4032) (Roche) was designed for the target therapy of melanoma which harbours BRAF-V600E mutation. CANCER MUTATION DETECTION CANCER MUTATION DETECTION KRAS Colorectal cancer (mCRC) is the fourth most common cancer among men and women. About 40% of mCRC patients have mutations of the KRAS gene in the tumor. Tumors with KRAS mutations in codons 12 or 13 are resistant to anti-EGFR therapy. Accordingly, anti-EGFR therapy of mCRC using Erbitux® or Vectibix® is recommended only for tumors without such mutations. EGFR Non-small cell lung cancer (NSCLC) is the most common type of lung cancer. About 10% of NSCLC cases have activating mutations in the epidermal growth factor receptor (EGFR) gene. Most of these somatic mutations (~90%) are within the tyrosine kinase (TK) domain of EGFR and occur as either an in-frame deletion of 3-6 amino acids that corresponds to codons 746-750 (del 746-750), or a missense mutation T2573G that leads to change of Leu to Arg at position 858 (L858R). The European Society for Medical Oncology (ESMO) and American Society of Clinical Oncology (ASCO) recommend EGFR mutation testing for selection of NSCLC patients who could benefit from anti-EGFR therapy. www.bioron.de 45 CANCER MUTATION DETECTION CANCER MUTATION DETECTION BRAF Product name RealLine BRAF Detect V600E, Kit for Real Time PCR RealLine BRAF Detect V600E, Kit for Real Time PCR Applications Indications for Testing Sample Material Cat. no Pack size MED20701 MED20710 12 rcs 36 rcs The kits are designed to detect missense mutation GTG→GAG at codon 600 of the BRAF gene which is associated with the sensitivity to the therapy with BRAF inhibitors. Also mutations of GTG to GAA, GAT, and AAG are detected by allele specific real time PCR. ● melanoma tumours and other BRAF associated tumors ● screening of the mutation for the decision of the therapy selection for the patient ● DNA extracted from fresh, fresh-frozen or formalin-fixed paraffin-embedded, (FFPE) tumor tissue section can be tested. ● FAM (495-520 nm) Real Time PCR Detection Channels BRAF-V600E ● ROX (575-602 nm) Internal Control IC Validated and Tested Cyclers ● Bio-Rad iQ™, iQ™5, CFX96™ (Bio-Rad, USA) ● LightCycler® Nano System (Roche, Switzerland) ● DTPrime, DTLite (DNA-Technology, Russia) Related Products Product name 46 Cat. no Pack size RealLine FFPE DNA Extraction Kit MED20301 50 rcs BRAF Standard DNA Kit MED32001 4 x 100 ng EGFR - Epithelial Growth Factor Receptor Product name RealLine EGFR Detect, L858R, Kit for real-time PCR RealLine EGFR Detect, L858R, Kit for real-time PCR EGFR Detect del 746-750, Kit for Standard PCR EGFR Detect del 746-750, Kit for Standard PCR Cat. no Pack size MED20501 MED20510 MED20601 MED20610 12 rcs 36 rcs 12 rcs 36 rcs The real time PCR EGFR-L858R kit is designed to detect missense mutation CTG>CGG at codon 858 of EGFR gene. Detection is made by allele-specific real time PCR-based assay. The kit is designed for in vitro diagnostics and provides qualitative detection. (new line) The EGFR-Del746-750 kit is designed to detect micro deletions in tyrosine kinase domain of EGFR gene that correspond to 746-750 amino acids in the protein sequence. Applications Indications for Testing Sample Material Real Time PCR Detection Channels Validated and Tested Cyclers ● Patients with tumors harboring either of these mutant forms of EGFR are extremely ® sensitive to the selective EGFR tyrosine kinase (TK) inhibitors gefitinib (IRESSA ) or ® erlotinib (TARCEVA ). ● DNA extracted from fresh-frozen or formalin-fixed paraffin-embedded (FFPE) tumor tissue sections can be tested. ● FAM (495-520 nm) EGFR Mutation-L858R ● ROX (575-602 nm) Internal Control IC CANCER MUTATION DETECTION CANCER MUTATION DETECTION ● Bio-Rad iQ™, iQ™5, CFX96™ (Bio- Rad, USA) ● AB 7500 (Applied Biosystems, USA) ● LightCycler® Nano System (Roche, Switzerland) Related Products Product name Cat. no Pack size RealLine FFPE DNA Extraction Kit MED20301 50 rcs EGFR Standard DNA Kit, L858R MED32201 4 x 100 ng EGFR-ex19del standards Kit MED32301 3 x 100 ng EGFR standards Kit MED32401 7 x 100 ng www.bioron.de 47 CANCER MUTATION DETECTION CANCER MUTATION DETECTION KRAS Product name RealLine KRAS Detect, Kit for Real Time PCR RealLine KRAS Detect, Kit for Real Time PCR Cat. no Pack size MED20401 MED20410 12 rcs 36 rcs The RealLine KRAS Detect kit is designed for the detection of 7 mutations in the codons 12 and 13 of the kRas gene by real-time PCR. Number Applications Mutation, amino acid 1 G12C 2 G12S 3 G12R 4 G12V 5 G12D 6 G12A 7 G13D * mutated nucleotide is underlined and marked in red. Mutant codon, nucleotides* TGT AGT CGT GTT GAT GCT GAC Indications for Testing ● Targeted therapy of metastatic colorectal cancer (mCRC) Sample Material ● DNA extracted from fresh, fresh-frozen or formalin-fixed paraffin-embedded (FFPE) tumor tissue section. Real Time PCR Detection Channels Validated and Tested Cyclers ● FAM (495-520 nm) KRAS mutations ● ROX (575-602 nm) Internal Control IC ● Bio-Rad iQ™, iQ™5, CFX96™ (Bio-Rad, USA) ● AB 7500 (Applied Biosystems, USA) ● LightCycler® Nano System (Roche, Switzerland) Related Products Product name 48 Cat. no Pack size RealLine FFPE DNA Extraction Kit MED20301 50 rcs KRAS Standard DNA Kit MED32101 2 x 200 ng Standard DNA for the Detection of Cancer Mutations Product name BRAF Standard DNA Kit EGFR Standard DNA Kit, L858R EGFR Standard DNA Kit, del 746-750 EGFR Standard DNA Kit, L858R & del 746-750 KRAS Standard DNA Kit Cat. no Pack size MED32001 MED32201 MED32301 MED32401 MED32101 4 x 100 ng 4 x 100 ng 3 x 100 ng 7 x 100 ng 2 x 200 ng DNA Standards containing the relevant KRAS, EGFR or BRAF mutations as positive mutation control and validation for in-house protocols. Applications Related Products Product name Cat. no Pack size RealLine FFPE DNA Extraction Kit MED20301 50 rcs RealLine EGFR Detect, L858R, Kit for real-time PCR RealLine EGFR Detect, L858R, Kit for real-time PCR EGFR Detect del 746-750, Kit for Standard PCR EGFR Detect del 746-750, Kit for Standard PCR RealLine BRAF Detect V600E, Kit for Real Time PCR RealLine BRAF Detect V600E, Kit for Real Time PCR RealLine KRAS Detect, Kit for Real Time PCR RealLine KRAS Detect, Kit for Real Time PCR MED20501 MED20510 MED20601 MED20610 MED20701 MED20710 MED20401 MED20410 12 rcs 36 rcs 12 rcs 36 rcs 12 rcs 36 rcs 12 rcs 36 rcs www.bioron.de CANCER MUTATION DETECTION CANCER MUTATION DETECTION 49 EXTRACTION KITS EXTRACTION OF KITS DNA Transportation Solution Product name Cat. no Pack size RealLine Transportation Solution VBC8894 100 rcs RealLine Transportation Solution is designed for the transportation and storage of clinical material for subsequent detection of pathogens using real time PCR. The RealLine Transportation Solution is compatible with most DNA extraction kits. The kit includes 100 sample tubes with 300 µl solution each. The Transportation Solution is intended for the storage of biological samples Specimens can be stored: • At room temperature – up to 2 days • At (2 – 8) °С – up to 2 weeks • Frozen at -20 °С – up to 2 months ● Biopsies ● Urine ● Sperm ● Epithelial cells specimen from: ● Cervical mucosa ● Urethra ● Vagina ● Posterior wall of the larynx Applications Sample Material RealLine DNA-Express RealLine DNA-Express Product name Cat. no Pack size RealLine DNA-Express VBC8899 100 rcs Reagent kits for rapid extraction of DNA. Allows independent extraction of DNA from 100 clinical samples. Applications RealLine DNA-Express kit is intended for use in clinical practice in the process of diagnostics of sexually transmitted infections (STI) or other infections. Sample Material ● epithelial cells e.g. from the mucosa of the cervical canal, urethra, vagina ● urine ● sperm Related Products Product name RealLine Transport Solution RealLine Internal Control 50 Cat. no Pack size VBC8894 VBC8881 100 rcs 250 rcs RealLine DNA - Extraction 2 Product name Cat. no Pack size RealLine DNA - Extraction 2 VBC8897 96 rcs RealLine DNA - Extraction 2 kit is intended for DNA extraction for in vitro diagnostics analysis. Allows to perform 4 independent extraction procedures of 24 samples per batch Applications ● Whole blood, serum, plasma ● Blood serum, plasma ● Biopsy material ● Liquor ● Urine ● Epithelial cells specimens Sample Material EXTRACTION KITS EXTRACTION OF KITS DNA EXTRACTION RealLine DNA - Extraction 3 Product name Cat. no Pack size RealLine DNA - Extraction 3 VBC8889 96 rcs Applications Sample Material RealLine DNA - Extraction 3 kit is intended for DNA extraction on a magnetic rack for in vitro diagnostics analysis. Allows to perform 6 independent extraction procedures of 16 samples per batch (including controls). ● Blood serum, plasma ● Urine ● Sperm ● Epithelial cells specimens Related Products Product name RealLine Transport Solution RealLine Magnetic Rack Cat. no Pack size VBC8894 VBE9258 or VBE9291 100 rcs 1 unit www.bioron.de 51 EXTRACTION KITS EXTRACTION OF KITS DNA & RNA RealLine Extraction 100 and 100 (A) Product name Cat. no Pack size RealLine Extraction 100, CE - IVD RealLine Extraction 100 (A) VBC8896 VBC8883 48 rcs 96 rcs RealLine Extraction 100 and 100 (A) are reagent kits for the extraction of DNA and RNA of 100 µl of clinical samples and optimised for use together with the RealLine kits. This extraction kit is designed for the simultaneous extraction of DNA and RNA from most clinical samples. RealLine Extraction 100A is optimized for the use in automatic systems. Applications ● Whole blood, serum, plasma ● Biopsy material ● Fluid ● Urine ● Tick suspension ● Epithelial cell scrapings Sample Material RealLine Extraction 1000 Product name RealLine Extraction 1000 Applications Sample Material Cat. no Pack size VBC8895 48 rcs RealLine Extraction 1000 is a reagent kit for the extraction of nucleic acids (DNA and RNA) of pathogens from blood serum (plasma). This kit is designed for the extraction of DNA and RNA from higher volumes (up to 1ml) to achieve high sensitive results and is intended for use together with the RealLine kits. ● Whole blood ● serum ● plasma Related Products Product name RealLine Transport Solution RealLine Magnetic Rack 52 Cat. no VBC8894 VBE9258 or VBE9291 Pack size 100 rcs 1 unit RealLine FFPE DNA Extraction Kit Product name RealLine FFPE DNA Extraction RealLine FFPE DNA Extraction Mag RealLine FFPE DNA Extraction Mag Cat. no Pack size MED20301 MED32501 MED32502 50 rcs 12 rcs 36 rcs The RealLine FFPE DNA – Extraction Kit is designed for extraction and purification of genomic DNA from formalin-fixed and paraffin-embedded (FFPE) tissue. The methods are fast and provide high DNA recovery particularly critical for small biopsies. Purified DNA can be used in PCR and real-time PCR. Applications Indications for Testing Sample Material Kit for the extraction of formalin-fixed paraffin embedded tissue (FFPE). The kit can be used for difficult and small sections of cancer tissue with a very high efficiency for the extractions of DNA. Patients with tumors harboring from mutant forms of EGFR, KRAS, BRAF Other tumors for testing of mutant genes EXTRACTION KITS EXTRACTION OF KITS DNA EXTRACTION ● Sections of formalin-fixed paraffin-embedded (FFPE) tissue can be used for DNA extraction. Related Products Product name Cat. no Pack size RealLine BRAF Detect V600E, Kit for Real Time PCR RealLine BRAF Detect V600E, Kit for Real Time PCR BRAF Standard DNA Kit MED20701 MED20710 MED32001 12 rcs 36 rcs 4 x 100 ng RealLine EGFR Detect, L858R, Kit for real-time PCR RealLine EGFR Detect, L858R, Kit for real-time PCR EGFR Detect del 746-750, Kit for Standard PCR EGFR Detect del 746-750, Kit for Standard PCR EGFR Standard DNA Kit, L858R MED20501 MED20510 MED20601 MED20610 MED32201 12 rcs 36 rcs 12 rcs 36 rcs 4 x 100 ng EGFR-ex19del standards Kit MED32301 3 x 100 ng EGFR standards Kit MED32401 7 x 100 ng RealLine KRAS Detect, Kit for Real Time PCR RealLine KRAS Detect, Kit for Real Time PCR KRAS Standard DNA Kit MED20401 MED20410 MED32101 12 rcs 36 rcs 2 x 200 ng www.bioron.de 53 PCR-KITS FOR PATHOGEN DETECTION OVERVIEW TABLES Overview: purpose and use of the RealLine Extraction Kits Product Cat.no. Clinical Material Extraction Detection of of RealLine DNA-Express CE-IVD RealLine DNA-Extraction 2 CE-IVD RealLine DNA-Extraction 3 CE-IVD RealLine Extraction 100 CE-IVD RealLine Extraction 100A (for automation) 54 Rcs 100 96 VBC8899 epithelial cell specimen, urine, sperm, saliva VBC8897 epithelial cell specimen, urine, liquor, biopsy material, blood serum/plasma VBC8889 epithelial cell specimen, urine blood serum/plasma 96 48 VBC8896 VBC8883 96 RealLine Extraction 1000 RUO 48 VBC8895 RealLine FFPE DNA Extraction Kit RUO 50 MED20301 epithelial cell specimen, liquor biopsy material blood serum/plasma blood serum/plasma Formalin-fixed and embedded tissue (FFPE tissue) DNA DNA DNA Sexually Transferred Diseases Human Herpes Viruses HPV types Parvovirus B19 Helicobacter pylori and most other pathogens Sexually Transferred Diseases Human Herpes Viruses HPV types Parvovirus B19 Borrelia and Anaplasma RNA and DNA Sexually Transferred Diseases Toxoplasma gondii Rubella, Borrelia, TBEV, Anaplasma Human Herpes Viruses; HPV types Parvovirus B19 HIV, HCV, HBV RNA and DNA HIV, HCV, HBV Borrelia, TBEV DNA KRAS, BRAF, EGFR OVERVIEW INTRODUCTION TABLES Cyclers tested with the RealLine Kits Tested Cyclers Bio-Rad iQ™ + iQ5™ iCycler CFX96™ Qiagen Rotor-Gene® 3000 Rotor-Gene® 6000 DNA-Technology DT-Prime DT-Lite Illumina Eco Real Time PCR Cycler Roche LightCycler® 1.5-2.0 LightCycler® 480 I+II LightCycler® Nano System Applied Biosystems ABI 7500 ABI 7300 Eppendorf Mastercycler Recommended Kit Formats Str-format and Fla-format Str-format and Fla-format Fla-format Fla-format Str-format and Fla-format Str-format and Fla-format Fla-format Fla-format and Uni-format Fla-format and Uni-format Fla-format and Uni-format Fla-format and Str-format Fla-format and Str-format Str-format and Fla-format For the recommended formats please see ‟Different formats for different cyclers” on page 6. Comments: The RealLine kits are designed for the use with block cyclers iQ™ iCycler, iQ5™ iCycler, CFX96™ (Bio-Rad, USA), DT96 (DNA-Technology Research and Production Company ZAO, Russia); rotor type cyclers Rotor-Gene® 3000, Rotor-Gene® 6000 and Rotor-Gene® Q (Qiagen, Germany), The use of - other suppliers' Extraction Kits for nucleic acids from clinical specimens - other real-time PCR devices - appropriate reaction volumes, other than the volumes indicated in the protocols have to be validated in the laboratory by the user. Special notes regarding the Internal Control IC must be followed stringently. www.bioron.de 55 PCR-KITS FOR PATHOGEN DETECTION OVERVIEW TABLES Available Samples of the RealLine Pathogen Kits Cat.no. RealLine Extraction 100 SVBC8896 12 VBC8896 DNA and RNA Extraction RealLine Extraction 1000 SVBC8895 12 VBC8895 DNA and RNA Extraction RealLine DNA - Extraction 2 SVBC8897 24 VBC8897 DNA Extraction RealLine DNA - Extraction 3 SVBC8889 24 VBC8889 DNA Extraction RealLine DNA- Express SVBC8899 30 VBC8899 DNA Extraction RealLine Internal control SVBC8881 50 VBC8881 Internal Control RealLine Transportation Solution SVBC8894 30 VBC8894 Transportation Solution SVBD0195 12 VBD0199 VBD0195 HIV quantitative SVBD0196 12 VBD0198 VBD0196 HIV qualitative SVBD0595 12 VBD0599 VBD0595 HBV quantitative SVBD0596 12 VBD0598 VBD0596 HBV qualitative RealLine HCV quantitative (Str-format) Matching Extraction: RealLine Extraction 100 (SVBC8896) SVBD0794 12 RealLine HCV qualitative (Str-format) Matching Extraction: RealLine Extraction 100 (SVBC8896) SVBD0795 12 RealLine HSV 1, 2 (Str-format) Matching Extraction: RealLine DNA- Extraction 3 (SVBC8889) SVBD2193 24 RealLine HIV quantitative (Str-format) Matching Extraction: RealLine Extraction 100 (SVBC8896) RealLine HIV qualitative (Str-format) Matching Extraction: RealLine Extraction 100 (SVBC8896) RealLine HBV quantitative (Str-format) Matching Extraction: RealLine Extraction 100 (SVBC8896) RealLine HBV qualitative (Str-format) Matching Extraction: RealLine Extraction 100 (SVBC8896) RealLine HSV 1, 2 (Fla-format) Matching Extraction: RealLine DNA- Extraction 3 (SVBC8889) RealLine HPV High Risk, Genotype qualitative (Strformat) Matching Extraction Kit: RealLine DNA- Extraction 3 (SVBC8889) RealLine HPV High Risk, Genotype quantitative (Strformat) Matching Extraction: RealLine DNA- Extraction 3 (SVBC8889) RealLine Mycobacterium tuberculosis (Uni-format) incl. Extraction RealLine TBEV (Str-format) 56 Rcs Sample method is comparable to the following catalogue numbers/ kits Available Samples SVBD2194 30 SVBD8479 24 VBD0799 VBD0797 VBD0794 VBD0798 VBD0793 VBD0795 VBD2195 VBD2185 VBD1598 VBD2198 VBD2150 VBD2148 VBD2193 VBD2197 VBD2187 VBD1596 VBD2196 VBD2151 VBD2149 VBD2194 HCV quantitative HCV qualitative Herpes Virus Family HSV, EBV, HHV, VZV, CMV VBD8482 VBD8479 HPV Genotypes SVBD8478 24 VBD8478 SVBD2398 12 VBD2398 TBC Tuberculosis SVBD1198 12 VBD2598 TBEV; Rubella OVERVIEW INTRODUCTION TABLES Available Samples Cat.no. Rcs Matching Extraction: RealLine Extraction 100 (SVBC8896) RealLine TBEV (Fla-format) Matching Extraction Kit: RealLine Extraction 100 (SVBC8896) VBD1198 SVBD1199 20 RealLine Borrelia burgdorferi (Str-format) Matching Extractions: RealLine Extraction 100 (SVBC8896) or RealLine DNA Extraction 3 (SVBC8889)* SVBD1498 12 RealLine Borrelia burgdorferi s.l. (Fla-format) Matching Extractions: RealLine Extraction 100 (SVBC8896) or RealLine DNA Extraction 3 (SVBC8889)* SVBD1499 20 RealLine Chlamydia trachomatis (Str-format) Matching Extractions: RealLine DNA- Extraction 3 (SVBC8889) or RealLine DNA-Express (SVBC8899)* SVBD1998 24 RealLine Chlamydia trachomatis (Fla-format) Matching Extractions: RealLine DNA- Extraction 3 (SVBC8889) or RealLine DNA-Express (SVBC8899)* SVBD1996 30 RealLine Trichomonas / Neisseria (Str-format) Matching Extraction Kit: RealLine DNA- Extraction 3 (SVBC8889) or RealLine DNA-Express (SVBC8899)* SVBD0496 24 RealLine Trichomonas / Neisseria (Fla-format) Matching Extraction Kit: RealLine DNA- Extraction 3 (SVBC8889) or RealLine DNA-Express (SVBC8899)* Sample method is comparable to the following catalogue numbers/ kits SVBD0495 30 VBD2596 VBD1199 VBD3798 VBD5398 VBD1798 VBD2801 VBD1498 VBD3796 VBD5399 VBD1796 VBD1499 VBD1998 VBD2098 VBD2298 VBD4396 VBD4398 VBD4498 VBD4598 VBD4698 VBD1996 VBD2096 VBD2296 VBC4394 VBD4393 VBD4496 VBD4596 VBD4696 VBD0490 VBD0492 VBD0498 VBD0494 VBD2294 VBD0444 VBD8473 VBD8471 VBD8469 VBD8465 VBD8464 VBD8475 VBD0496 VBD0477 VBD0491 VBD0497 VBD0487 VBD0493 VBD2295 VBD0445 VBD8474 VBD8480 VBD8477 VBD8463 VBD8461 VBD8481 VBD0495 VBD0478 Borrelia, Anaplasma/Ehrlichia, Helicobacter, Parvovirus B19 and Toxoplasma STI (sexually transferred diseases) STI Double Kits HPV Double Kits www.bioron.de 57 OVERVIEW TABLES Certification Status PCR KITS FOR PATHOGEN DETECTION 58 Sexually Transmitted Infections (STI) RealLine Candida albicans (Str-format) RealLine Candida albicans (Fla-format) VBD4698 VBD4696 CE-IVD CE-IVD RealLine Chlamydia trachomatis (Str-format) RealLine Chlamydia trachomatis (Fla-format) VBD1998 VBD1996 CE-IVD CE-IVD RealLine Gardnerella vaginalis (Str-format) RealLine Gardnerella vaginalis (Fla-format) VBD4598 VBD4596 CE-IVD CE-IVD RealLine Mycoplasma genitalium (Str-format) RealLine Mycoplasma genitalium (Fla-format) VBD4396 VBD4394 CE-IVD CE-IVD RealLine Mycoplasma hominis (Str-format) RealLine Mycoplasma hominis (Fla-format) VBD4398 VBD4393 CE-IVD CE-IVD RealLine Neisseria gonorrhoeae (Str-format) RealLine Neisseria gonorrhoeae (Fla-format) VBD4498 VBD4496 CE-IVD CE-IVD RealLine Trichomonas vaginalis (Str-format) RealLine Trichomonas vaginalis (Fla-format) VBD2098 VBD2096 CE-IVD CE-IVD RealLine Ureaplasma urealyticum (Str-format) RealLine Ureaplasma urealyticum (Fla-format) VBD2298 VBD2296 CE-IVD CE-IVD STI Multiplexing Kits RealLine Candida / Gardnerella (Str-format) RealLine Candida / Gardnerella (Fla-format) VBD0444 VBD0445 CE-IVD CE-IVD RealLine Chlamydia / Ureaplasma urealyticum (Str-format) RealLine Chlamydia / Ureaplasma urealyticum (Fla-format) VBD0492 VBD0491 RUO RUO RealLine Chlamydia / Neisseria (Str-format) RealLine Chlamydia / Neisseria (Fla-format) VBD0457 VBD0458 RUO RUO RealLine Chlamydia / Trichomonas (Str-form) RealLine Chlamydia / Trichomonas (Fla-format) VBD0498 VBD0497 RUO RUO RealLine Chlamydia / Mycoplasma genitalium (Str-format) RealLine Chlamydia / Mycoplasma genitalium (Fla-format) VBD0490 VBD0487 RUO RUO RealLine Mycoplasma hominis/ genitalium (Str-format) RealLine Mycoplasma hominis/ genitalium (Fla-format) VBD0494 VBD0493 CE-IVD CE-IVD OVERVIEW INTRODUCTION TABLES RealLine Ureaplasma urealyticum/ parvum (Str-format) RealLine Ureaplasma urealyticum/ parvum (Fla-format) VBD2294 VBD2295 CE-IVD CE-IVD RealLine Trichomonas / Neisseria (Str-format) RealLine Trichomonas / Neisseria (Fla-format) VBD0496 VBD0495 CE-IVD CE-IVD RealLine Trichomonas / Gardnerella (Str-format) RealLine Trichomonas / Gardnerella (Fla-format) VBD0477 VBD0478 CE-IVD CE-IVD Human Papilloma Virus (HPV) RealLine HPV 16 / 18 (Str-format) RealLine HPV 16 / 18 (Fla-format) VBD8473 VBD8474 CE-IVD CE-IVD RealLine HPV 31 / 33 (Str-format) RealLine HPV 31 / 33 (Fla-format) VBD8471 VBD8480 CE-IVD CE-IVD RealLine HPV 35 / 45 (Str-format) RealLine HPV 35 / 45 (Fla-format) VBD8469 VBD8477 CE-IVD CE-IVD RealLine HPV high carcinogenic risk, Genotype (Str-format) RealLine HPV high carcinogenic risk, Genotype (Fla-format) VBD8479 VBD8482 CE-IVD CE-IVD RealLine HPV high carcinogenic risk, Genotype, quant. (Strformat) VBD8478 Mycobacterium tuberculosis (TB) RealLine Mycobacterium tuberculosis (Uni-format) incl. extraction RealLine Mycobacterium tuberculosis (Str-format) VBD2398 CE-IVD CE-IVD CE-IVD Human Herpes Viruses (HHV) RealLine CMV (Str-format) RealLine CMV (Fla-format) VBD1598 VBD1596 CE-IVD CE-IVD RealLine EBV (Str-format) RealLine EBV (Fla-format) VBD2198 VBD2196 CE-IVD CE-IVD RealLine HSV-1/ HSV-2 RealLine HSV-1/ HSV-2 VBD2195 VBD2197 CE-IVD CE-IVD RealLine HHV - 6 (Str-format) RealLine HHV - 6 (Fla-format) VBD2150 VBD2151 CE-IVD CE-IVD RealLine HHV - 8 (Str-format) RealLine HHV - 8 (Fla-format) VBD2148 VBD2149 CE-IVD CE-IVD RealLine VZV (Str-format) RealLine VZV (Fla-format) VBD2185 VBD2187 CE-IVD CE-IVD www.bioron.de 59 PCR-KITS FOR PATHOGEN DETECTION OVERVIEW TABLES 60 Tick Borne Infections RealLine TBEV (Str-format) RealLine TBEV (Fla-format) VBD1198 VBD1198 VBD1199 CE-IVD CE-IVD CE-IVD RealLine Borrelia burgdorferi s.l. (Str-format) RealLine Borrelia burgdorferi s.l. (Fla-format) VBD1498 VBD1499 CE-IVD CE-IVD RealLine Anaplasma / Ehrlichia (Str-format) RealLine Anaplasma / Ehrlichia (Fla-format) VBD5398 VBD5399 CE-IVD CE-IVD Rubella RealLine Rubella (Str-format) RealLine Rubella (Fla-format) VBD2598 VBD2596 CE-IVD CE-IVD Toxoplasma RealLine Toxoplasma gondii (Str-format) RealLine Toxoplasma gondii (Fla-format) VBD1798 VBD1796 CE-IVD CE-IVD Parvovirus B19 RealLine Parvovirus B19 (Str-format) RealLine Parvovirus B19 (Fla-format) VBD2801 VBD2802 RUO RUO Helicobacter pylori RealLine Helicobacter pylori (Str-format) RealLine Helicobacter pylori (Fla-format) VBD3798 VBD3796 CE-IVD CE-IVD HIV (Human Immunodeficency Virus) RealLine HIV qualitative (Uni-format) incl. extraction RealLine HIV quantitative (Uni-format) incl. extraction VBD0198 VBD0199 RUO RUO RealLine HIV quantitative (Str-format), RealLine HIV qualitative (Str-format) VBD0195 VBD0196 RUO RUO HCV (Hepatitis C Virus) RealLine HCV qualitative (Uni-format), incl. extraction RealLine HCV quantitative (Uni-format), incl. extraction VBD0798 VBD0799 RUO RUO RealLine HCV qualitative (Str-format) RealLine HCV quantitative (Str-format) VBD0795 VBD0794 RUO RUO RealLine HCV Genotype qualitative (Uni-format) RealLine HCV Genotype quantitative (Str-format) VBD0793 VBD0797 RUO RUO HBV (Hepatitis B Virus) RealLine HBV qualitative (Uni-format) incl. extraction RealLine HBV quantitative (Uni-format), incl. extraction VBD0598 VBD0599 RUO RUO RealLine HBV, qualitative (Str-format) RealLine HBV, quantitative (Str-format) VBD0596 VBD0595 RUO RUO SUPPLEMENTARY PRODUCTS RealLine Internal Control (2 x 2 ml) VBC8881 RUO RealLine Magnetic Rack RealLine Magnetic Rack with exchangeable covers VBE9258 VBE9291 OVERVIEW INTRODUCTION TABLES KITS FOR CANCER RELATED MUTATIONS ANALYSIS BRAF RealLine BRAF Detect, V600E, Kit for real-time PCR RealLine BRAF Detect, V600E, Kit for real-time PCR BRAF Standard DNA Kit MED20701 MED20710 MED32001 RUO RUO RUO EGFR RealLine EGFR Detect, L858R, Kit for real-time PCR RealLine EGFR Detect, L858R, Kit for real-time PCR EGFR Detect del 746-750, Kit for Standard PCR EGFR Detect del 746-750, Kit for Standard PCR RealLine EGFR Detect, L858R, Kit for real-time PCR RealLine EGFR Detect, L858R, Kit for real-time PCR EGFR Detect del 746-750, Kit for Standard PCR MED20501 MED20510 MED20601 MED20610 MED20501 MED20510 MED20601 RUO RUO RUO RUO RUO RUO RUO KRAS RealLine KRAS Detect, DNA for real-time PCR RealLine KRAS Detect, Kit for real-time PCR KRAS Standard DNA Kit MED20401 MED20410 MED32101 RUO RUO RUO KITS FOR EXTRACTION OF NUCLEIC ACIDS Transportation solution VBC8894 CE-IVD RealLine DNA - Express VBC8899 CE-IVD RealLine DNA - Extraction 2 RealLine DNA - Extraction 3 VBC8897 VBC8889 CE-IVD CE-IVD RealLine Extraction 100 RealLine Extraction 100 (A) RealLine Extraction 1000 VBC8896 VBC8883 VBC8895 CE-IVD RUO RUO RealLine FFPE DNA Extraction Kit RealLine FFPE DNA Extraction Mag RealLine FFPE DNA Extraction Mag MED20301 MED32501 MED32502 RUO RUO RUO For RealLine Kits which are marked with RUO*, certification is still in process www.bioron.de 61 ALPHABETICAL LIST OF PRODUCTS Alphabetical Product List A Anaplasma phagocytophilum page RealLine Pathogens 34 RealLine Pathogens 46 35 RealLine Pathogens RealLine Pathogens RealLine Pathogens RealLine Pathogens RealLine Cancer RealLine Cancer 8, 16 9, 17 28 28 45 45 RealLine Extraction 50 RealLine Pathogen RealLine Cancer RealLine Pathogen RealLine Pathogen RealLine Extraction RealLine Pathogen 29 47 34 34 50 29 RealLine Extraction 53 RealLine Pathogen 10, 16 RealLine Pathogen RealLine Pathogen RealLine Pathogen RealLine Pathogen RealLine Pathogen RealLine Pathogen RealLine Pathogen RealLine Pathogen RealLine Pathogen RealLine Pathogen RealLine Pathogen RealLine Pathogen RealLine Pathogen 40 30 25 28 41 42 43 41 42 43 25 30 31 RealLine Pathogen RealLine Extractions 6, 44 6, 44 B Borrelia burgdorferi s.l. BRAF RealLine Cancer C Candida albicans Chlamydia trachomatis Cytomegalovirus (CMV) CMV Cancer Colorectal cancer D DNA E EBV EGFR Ehrlichia muris Ehrlichia chaffeensis Extraction DNA/RNA Eppstein Barr Virus (EBV) F FFPE G Gardnerella vaginalis H Helicobacter pylori Herpes Simplex Virus 1&2 (HSV 1,2) Human Papilloma Virus (HPV) Human Herpes Viruses (HHV) Human Immunodeficiency Virus (HIV) Herpes C Virus (HCV) Herpes B Virus (HBV) HIV HCV HBV HPV HSV HHV I Internal Control (IC) IC 62 ALPHABETICAL LISTINTRODUCTION OF PRODUCTS K KRAS RealLine Cancer 48 RealLine Cancer 47 RealLineSupplementory Products RealLine Pathogens RealLine Pathogens RealLine Pathogens RealLine Extractions RealLine Cancer Mutation 44 11 12 27 50 45 Neisseria gonorrhoeae RealLine Pathogen 13 Oncogenes R Rubella RNA RealLine Cancer 45 RealLine Pathogens RealLine Extractions 37 52 RealLine Pathogens RealLine Pathogens 8, 16 8, 16 RealLine Extractions RealLine Pathogens RealLine Pathogens RealLine Pathogens 50 14 34 36 RealLine Pathogens RealLine Cancer 15 45 RealLine Pathogens RealLine Pathogens 33 33 L Lung cancer M Magnetic rack Mycoplasma genitalium Mycoplasma hominis Mycobacterium tuberculosis Magnetic beads Melanoma N O S STI Sexually Transmitted Diseases (STI) T Transport Solution Trichomonas vaginalis Tick-Borne- Encephalitis Virus (TBEV) TBEV U Ureaplasma urealyticum Tumor V Varicella Zoster Virus (VZV) VZV www.bioron.de 63 CONDITION OF SALES General terms and conditions of BIORON Diagnostics GmbH I General information Scope Warning 1. Deliveries and performance from BIORON Diagnostics shall be executed solely in accordance with the following standard terms of contract. These standard terms of contract shall apply to transactions conducted with businessmen and entrepreneurs in compliance with § 14 BGB (Federal Statutes at Large). These standard terms of contract shall apply to all future transactions between the partners to the agreement, without special further reference. They shall also apply to future agreements even if BIORON Diagnostics does not explicitly quote the terms, in particular when BIORON Diagnostics having knowledge of alternative terms of purchase or of terms deviating from the standard terms of delivery or performance stipulated in the contract. You have already been notified of the standard terms of contract by means of our standard forms as well as via e-mail messages and publications in the Internet. The scope of application of these standard terms of contract shall also be valid in all supplier countries 2. BIORON Diagnostics products are exclusively designed for application within the research and laboratory sector. A usage in connection with persons, animals, in households or in other forms of private use is forbidden. The application of the products in the diagnostic or therapeutic sector is forbidden. The resale of BIORON Diagnostics products to private individuals is not permitted. BIORON Diagnostics shall not be liable for damage to objects or injury to persons caused by improper application, treatment or storage. We draw special attention to the regulations stated in Sections VII. to IX. Unless explicitly stated, no licence or immunity under any patent is either granted or implied by the sale of any of our products. BIORON Diagnostics does not warrant that the resale or use of its products delivered will not infringe the claims of any patents, trademarks or copyright covering use of the product itself, or its use in combination with any other products, or its use in the operation of any process. Furthermore, the purchaser assumes all risks of patent, trademark or copyright infringement associated with any such use, combination or operation. 3. Some of the BIORON Diagnostics products may be toxic or hazardous and are therefore designated as such in compliance with the statutory regulations. An omission of safety hazard warnings on the labels of BIORON Diagnostics products does not mean that the respective product is harmless. BIORON Diagnostics also draws special attention to the regulations defined in Sections VII. to IX here. 4. BIORON Diagnostics has the intent to supply solely to commercial enterprises, public research-, analytical laboratories and educational facilities. Customers who do not belong to this specified clientele shall be obliged to provide BIORON Diagnostics with information pertaining to the status and/or business operations of their company res. person on establishment of contact res. placement of order. If the relevant information is not furnished, BIORON Diagnostics shall be exempted from any liability resulting thereof. BIORON Diagnostics shall be entitled to reject orders if there is a possibility that their products may be used in an unauthorized manner. II Tenders and Conclusion of Agreement Performance 1. BIORON Diagnostics tenders to the prospective customer shall be subject to confirmation. The placing of an order by the customer shall be binding. The acceptance of the order will follow within four (4) weeks by means of the dispatching of a confirmation of order or unconditional execution of the consigned deliveries or performance. 2. The technical data and descriptions in the respective product information or advertising material from BIORON Diagnostics shall not present a guarantee for the quality or durability of goods delivered or supplied by BIORON Diagnostics. Warranties will not be furnished unless these have been explicitly agreed upon in separate contracts. 3. In connection with the above mentioned Paragraph 2 BIORON Diagnostics draws particular attention to the fact that BIORON Diagnostics gives all information related to the origin, state, nature, condition, quality and the manufacturing process of the primary product and.In this context, BIORON Diagnostics is mostly depending and relying on the information, promises, assurances, confirmations and certificates provided by its suppliers. BIORON Diagnostics at its stage of production is not able to conduct extensive product testing with all products. As for these reasons it is not possible to trace back in every single case, BIORON Diagnostics denies all liability in that respect. 4. In the case of sales in accordance with samples or specimens, this shall merely describe the professional compliance with the sample or specimen, but shall not be a guarantee for the composition or durability of the goods to be delivered by BIORON Diagnostics or the performance to be executed. III Prices Terms of payment Default of payment 1. The prices determined by the conclusion of the respective agreement, in particular the prices stipulated in the order form res. the confirmation of order in EURO shall be valid. If a price is not explicitly defined, the prices, which are valid at the time when the agreement is concluded in accordance with the current BIORON Diagnostics price list, should be valid. The statutory valueadded tax valid on the day of delivery shall be added to the defined prices. 2. The products shall be delivered ex factory. The prices shall include the costs of packaging required for the regular shipment of goods together with the reimbursement for the disposal of the sales-, and transport packaging. The prices do not include transport costs or costs for a transportinsurance, if this has not been previously agreed upon. The terms of packaging and transport must be concluded separately for goods to be delivered abroad. 3. BIORON Diagnostics shall reserve the right to modify prices in a reasonable manner if alterations in costs e.g. due to wage settlements, price increases by suppliers, fluctuations in the monetary exchange rates or other important reasons should arise after the conclusion of the agreement. 4. Invoices received from BIORON Diagnostics must be paid within ten days from receipt of the invoice minus two percent (2%) discount, if no other terms have been concluded. The customer shall be in default of payment after the expiry of the settlement date stated in the invoice in compliance with § 286 Section 2 No. 2 BGB (Federal Statutes at Large). In compliance with § 288 BGB (Federal Statutes at Large) default interest will be calculated from the day of expiry of the settlement date with reservation to assertion of further claims. 5. The customer may only exercise the option of offsetting or retention if his counter-claims have been legally justified and BIORON Diagnostics have neither recognized nor disputed the claims within two (2) weeks of notification. 6. If the customer should not pay invoices due, after the term of credit has expired, or if the financial circumstances of the customer should deteriorate following the conclusion of the agreement or if BIORON Diagnostics should receive unfavorable information pertaining to the customer that queries the solvency of the customer, BIORON Diagnostics shall be justified in taking measures to procure the entire residual amount from the customer and via an amendment of the payment terms concluded advance payment or collateral security or immediate settlement of all its claims. This shall apply, in particular, if the customer does not meet his payments, or a cheque from the customer is dishonoured, a bill of draft furnished by the customer shall not be redeemed, a bankruptcy process relating to the assets of the customer has been petitioned or initiated or when insolvency proceedings have not been initiated due to insufficient assets. IV Time of delivery and performance Default 1. The validity of delivery schedule shall be considered roughly stated if a fixed delivery date has not been concluded in writing. However, when BIORON Diagnostics has exceeded determined delivery schedules due to justifiable circumstances, the customer shall have the option to withdraw from the agreement after an additional respite following the fruitless expiry of a reasonable period stated by the customer. The withdrawal from the agreement must be furnished in writing. 2. BIORON Diagnostics shall only be in default following the expiry of a reasonable additional respite of time. In cases of Force Majeure (Act of God) and other unforeseeable, extraordinary circumstances, which cannot be influenced by BIORON Diagnostics such as like disturbance in operation as a result of fire, water and similar circumstances, breakdown of production systems and machinery, exceeding the term of delivery or failure to deliver on the part of suppliers together with interruptions in operation due to a shortage of raw materials, energy or working force, strikes, shut-out, problems with the acquisition of transport, traffic disturbance, official administrative measures, BIORON Diagnostics – as far as BIORON Diagnostics is hindered to fulfil its obligations not due to its own fault – shall be entitled to postpone delivery or performance until the extraordinary circumstances have been alleviated and shall be granted a reasonable respite. If delivery or performance should be delayed by more than two months hereby, both BIORON Diagnostics and the customer shall be entitled to furnish written notice of withdrawal from the agreement under the ruling out of claims to indemnification with regard to the bulk amount influenced by the disturbance in delivery. 3. In every case of default the liability of BIORON Diagnostics to pay compensation is limited by the stipulation of the regulations in Section VIII No. 1 to 6. 4. BIORON Diagnostics is entitled to furnish partial deliveries or performance within the scope of the agreed times of delivery and performance if this is acceptable to the customer. V Passing of risk Handling of packaging 1. Risk and costs shall pass to the customer upon shipment in so far as no deviating provisions have been defined. The risk of accidental perishing, loss or destruction and of incidental deterioration of the object of delivery passes to the customer on surrender of the consignment to the haulage company (even in the case of deliveries which have been insured against transport damage by BIORON Diagnostics). 2. Packaging and containers may not be used for other purposes or for storage of other products. They are exclusively intended for the transport of goods delivered by BIORON Diagnostics. Labels may not be removed. BIORON Diagnostics will not take one-way packaging back. The customer must dispose of this packaging in the authorized manner. In particular it must be ensured that emptied containers must not be employed for the storage of other materials. The disposal costs have been included into our prices by means of a corresponding compensation (Section III. Paragraph 2., Regulation 2). If another deviating provision has been concluded, BIORON Diagnostics shall inform the customer or a third party who will accept the packaging in accordance with the statutory legislation pertaining to packaging disposal in return for reasonable remuneration. VI Customer obligations Reservation of title 1. BIORON Diagnostics shall retain title to the delivered products until the entire payment of the purchase price and all pending additional, current or future demands resulting from business relations with the customer has been settled. The settlement of the in an outstanding invoice and the acceptance of the balance of another invoice shall not affect the reservation of title. 2. The customer shall be obliged to treat the purchased goods carefully, in particular he shall be obliged to insure the goods with the cost price against loss and damage and destruction, e.g. against damage caused by fire, water and theft at his own costs. The customer shall cede his claims resulting from the insurance policies to BIORON Diagnostics at once. BIORON Diagnostics shall accept the assignment of the claims herewith. 3. The customer may neither pledge nor give as a security the goods for which BIORON Diagnostics has the reservation of title. However, he shall be entitled to sell the delivered goods within the scope of a correct business transaction in accordance with the following terms. The previously mentioned justification shall not hold in as far as the customer transfers or pledges claims against his contractual partner, resulting from the resale of the goods, to a third party or has concluded an effective prohibition of assignment in advance. 4. The customer shall immediately assign to BIORON Diagnostics all – including future and contingent – accounts receivable to be acquired from a resale of the goods delivered by BIORON Diagnostics for the securing of the fulfilment of claims dealt with in Section VI No. 1 together with all ancillary rights at a sum of 110% gross of the value of the delivered goods which will take precedence over the residual sum of his accounts receivable. BIORON Diagnostics shall accept the assignment herewith. 64 CONDITION INTRODUCTION OF SALES 5. As long as and as far as the customer settles his payment obligations to BIORON Diagnostics, he shall be entitled to the collection of claims assigned to BIORON Diagnostics within the scope of the regular management. However, he shall not be entitled to conclude an current accounts agreement to a third party or prohibition of assignment with his customers in relation to these claims or to transfer or pledge these to third parties. If in contrast to regulation 2 a current account agreement should exist between the customer and the purchaser of BIORON Diagnostics’s reservation goods, the previously assigned claim shall also relate to the accepted balance as well as to the existing balance in the case of insolvency of the purchaser. 6. On demand of BIORON Diagnostics the customer shall be required to establish the accounts receivable which he has assigned to BIORON Diagnostics separately and to notify his debtors of the assignment with the request to pay all outstanding invoices to BIORON Diagnostics up to the value of the claims to the customer. BIORON Diagnostics shall be entitled to notify the debtors of this arrangement at any time and to collect the claims, if necessary. However BIORON Diagnostics will only make use of this authorization if the customer fails to meet his financial obligations or is in default, or when an insolvency process has been initiated against the customer, or the customer ceases to pay the invoices. If one of the aforementioned cases should arise, BIORON Diagnostics can demand that the customer notifies BIORON Diagnostics of the assigned claims and the debtors thereof in detail and furnishes all relevant information pertaining to the collection of the accounts receivable and hands over the respective documents. 7. In the case of seizures or any other interference of third parties, the customer shall immediately (without undue delay) inform BIORON Diagnostics in writing in order to enable BIORON Diagnostics to react in an appropriate manner and, if necessary, to bring an action according to § 771 Code of Civil Procedure. 8. BIORON Diagnostics shall be obliged to release all securities furnished by the customer, if he requires, in the event when realisable value of the securities should exceed BIORON Diagnostics’s account receivables from the customer by more than twenty percent (20%). 9. In the case of customer behaviour which is contrary to the terms of the agreement, in particular in the case of default of payment exceeding ten percent (10%) of the balance due for a not insignificant period of time, BIORON Diagnostics – irrespective of further outstanding or pending (compensation) claims – shall be entitled to withdraw from the agreement and demand return of the goods delivered. BIORON Diagnostics shall be authorized to reprocess the returned goods in the required manner. The profits resulting from the reprocessing of the goods must be credited to the outstanding accounts payable to BIORON Diagnostics by the customer minus the appropriate reprocessing expenses. VII Duties on receiving of incoming goods Rights of customer in case of non-conformity 1. The customer is obliged to subject the delivered goods to the customs control on receiving, immediately. 2. Obvious defects, delivery of wrong goods, and variation in quantity must be reported to BIORON Diagnostics by the customer immediately (without undue delay), or must be reported in writing within seven (7) days, at the latest from the receiving of the goods. Hidden defects must be reported to BIORON Diagnostics in writing within a period of eight (8) days following the discovery of non-conformity. Notice of hidden defects in quality or quantity shall be excluded and shall be deemed belated after three (3) months beginning with the passing of the risk to the customer according to Section V No. 1,in the case of the hidden defects were reasonably recognizable. In the case of a belated or not appropriate notice of defect according to Section VII, the customer shall loose all rights to indemnification, except if the defect was fraudulently concealed by BIORON Diagnostics. 3. In the case of non-conformity of goods supplied by BIORON Diagnostics, BIORON Diagnostics shall only be obliged to rework the goods or deliver goods free from defects (subsequent fulfilment of contractual obligations). If BIORON Diagnostics is not prepared to carry out reworking or is not in a position to fulfils these measures, due to the fact that the time to get these measures could be prolonged for reasons for which BIORON Diagnostics is responsible or if the reworking or fulfilment of the obligations should not succeed for other reasons, the customer shall be entitled to withdraw from the contract or to demand a reduction of the purchase price. A reworking shall be deemed to have failed following the third unsuccessful attempt if no other measures have been stipulated. If the customer has incurred damage or suffered from futile expenditures resulting from non-conformity of goods delivered by BIORON Diagnostics, the liability of BIORON Diagnostics in this case is stipulated in Section VII No. 1, Section VIII No. 1 to 6 and Section IX. VIII Rights and obligations of BIORON Diagnostics 1. A liability on the part of BIORON Diagnostics for damage or futile expenditures – irrespective of the legal basis – shall only arise in the case where the damage or futile expenditures: ● have been caused by BIORON Diagnostics or by one of their authorized personnel or subcontractors by means of culpable violation of a significant contractual obligation or ● are due to a grossly negligent or intentional violation of obligations on the part of BIORON Diagnostics or one of their subcontractors. 1. In compliance with Section VIII No. 1 Letter a) and b) BIORON Diagnostics shall not be liable for damage or futile expenditures, which have been caused by consulting measures or information provided, were not settled separately, but solely in the case of intentional or grossly negligent breach of obligations, in so far as the breach of duties has not led to material defect according to § 434 BGB in the goods delivered by BIORON Diagnostics. 2. If BIORON Diagnostics should be liable for the violation of a fundamental contractual duty in compliance with Section VIII No. 1 letter a), without evidence of gross negligence or intent, the liability to compensation shall be limited to the foreseeable and typically arising damage. In this case BIORON Diagnostics shall not be held liable for loss of profit to the customer and also not for unforeseeable consequential damages. The previously mentioned limitations in accordance with regulations 1 and 2 are equally applicable for damages resulting from gross negligence or intent on the part of BIORON Diagnostics personnel or authorized persons. 3. BIORON Diagnostics shall not be liable for consequential loss of the customer, which arise because of assertion of a claim to contract penalties of a third party. 4. If BIORON Diagnostics shall be liable for the infringement of a fundamental contractual obligation in compliance with Section VIII No. 1 letter a), without evidence of gross negligence or intent, their liability is limited to the sum of 1,0 Mio Euros per event of damage. BIORON Diagnostics shall be obliged to effect and maintain an insurance to cover claims up to 1.5 million Euros. 5. The liability limitations mentioned in Section VIII No. 1 to 3 shall not apply if BIORON Diagnostics’s liability is in compliance with the regulations contained in the Product Liability Law, or when claims have been raised due to loss of life, injury to body or health, or when BIORON Diagnostics has guarantied a special property; BIORON Diagnostics shall only be liable for such damage which is covered by the property. 6. BIORON Diagnostics is not liable to pay an extent compensation other than stipulated in Section VIII No. 1 to 4, irrespective of the nature of valid claims. This especially applies to damage claims resulting from negligence in the course of conclusion of the agreement in compliance with § 311 Section 3 BGB, violation of contractual duty in compliance with § 280 BGB or due to claims in tort in compliance with § 823 BGB. 7. In the case the liability for damages is excluded or limited in compliance with Section VIII No. 1 to 5, this shall also apply for all personal liability for damages of the staff, personnel, colleagues, representatives and subcontractors as well as vicarious agents employed or engaged by BIORON Diagnostics. IX Limitation of claims 1. Customer claims pertaining to defects in goods delivered by BIORON Diagnostics or relating to unauthorized performance on the part of BIORON Diagnostics – including claims for compensation and claims to replacement of futile expenditure – shall be limited to a period of two (2) years from the beginning of the statutory limitation period, in as far as no other provisions have been defined in the following Section IX No. 2 and 3. 2. If BIORON Diagnostics has provided incorrect consulting that is not invoiced separately (1) either without delivering goods in connection with incorrect consulting or (2) without incorrect consulting creating a defect of the goods delivered because of incorrect consulting (§ 434 BGB), the respective claims of the customer shall be subject to a limitation period of one year from the beginning of the statutory limitation period. Claims raised by the customer against BIORON Diagnostics resulting from the violation of contractual, pre-contractual or statutory obligations pertaining to substances delivered by BIORON Diagnostics which do not exhibit non-conformity in compliance with § 434 BGB shall also be subject to a limitation period of one year from the beginning of the statutory limitation period. In so far as the mentioned breach of obligations is responsible for non-conformity of products delivered by BIORON Diagnostics in compliance with § 434 BGB because of wrong consulting or advice, claims dealt with shall be subject to the same statutory period of limitation as contained in Number 1 above. 3. The provisions covered by sections 1 and 2 shall not apply to the limitation of claims resulting from loss of life, injuries to body and health as well as the limitation of claims in compliance with the legislation pertaining to product liability. Furthermore, they shall not apply to the limitation of claims submitted by BIORON Diagnostics’s customers made on the basis that non-conformity of substances delivered by BIORON Diagnostics has been fraudulently concealed or a contractual obligation has been intentionally violated or in cases of gross negligence. The statutory term of limitation shall apply to limitation in the case of any of these aforementioned cases. X Assignment and Transfer of Claims Contractual obligations of BIORON Diagnostics or claims raised against BIORON Diagnostics, in particular resulting from non-conformity of products delivered by BIORON Diagnostics or from the breach of contractual obligations on the part of the BIORON Diagnostics cannot be completely or partially transferred or pledged to third parties without the explicit written agreement of BIORON Diagnostics; § 354 a of the Handelsgesetzbuch (Code of Commercial Law) shall be untouched by these measures. XI Place of performance Place of jurisdiction Applicable law Trade stipulations 1. The Place of performance and the sole place of jurisdiction for all claims between BIORON Diagnostics and business or legal entities of a statutory company or where statutory fund assets are involved is Ludwigshafen/Rhein; in so far as there are no mandatory statutory regulations in contradiction to these measures. However, BIORON Diagnostics shall also have the right to initiate legal proceedings against a customer in the District Court at the place of jurisdiction of the customer. 2. Exclusively the legislation of the Federal Republic of Germany shall apply to the legal relations between BIORON Diagnostics and the customer, as is customary between German businessmen and which can be effectively agreed upon within the respective supplier countries (see Section I of these terms of sales). The application of regulations pertaining to the Unified international Purchase Laws (CISG – UN Purchase Law) and the German Private Law is explicitly excluded. 3. In so far as trade stipulations have been agreed in compliance with International Commercial Terms (INCOTERMS), the latest edition of the INCOTERMS shall be valid (currently INCOTERMS 2000). XII Final provisions 1. Should one of the above mentioned provisions be invalid, partially invalid or excluded by a special agreement, this shall hereby not affect the validity of the remaining provisions. 2. BIORON Diagnostics will store the data of its customers within the scope of their mutual business relations in accordance with the legislation of the Federal Republic of Germany relating to data protection. The General Manager of BIORON Diagnostics GmbH (December 2010) www.bioron.de 65 IMPRINT Imprint BIORON Diagnostics GmbH Rheinhorststr. 18 67071 Ludwigshafen Germany Phone +49 621 5459 0070 Fax +49 621 5459 0068 [email protected] www.bioron.de Legal form: Limited liability company Managing Director: Dr. Ferdinand Holzinger Commercial register: AG Ludwigshafen HRB 62298 Registered Office: Ludwigshafen Value Added Tax Identification Number (VAT ID) DE 274 094 961 German tax No. 27/656/0100/9 Conditions of Sales/ Export Please view the Conditions of Sales at our Website www.bioron.de. 66 www.bioron.de 67 BIORON Diagnostics GmbH is a worldwide acting trader of diagnostic products. Our customers are distributors, hospitals & diagnostic labs, research institutes and biotech companies of all sizes. We have experience in OEM- & Tender businesses. We focus on research and innovation in all sectors where superior technology is required, such as Affordable molecular pathogen diagnostic PCR Thermocycler ● Laboratory equipment ● ● BIORON products fulfill highest quality & health standards. Our customers value us for our individual concern and support. BIORON Diagnostics GmbH (Germany) Telefon: 0049 621 545 900 70 Telefax: 0049 621 545 900 68 E-mail:[email protected] www.bioron.de
© Copyright 2024