COVER OptiChill Air Cooled Screw Chiller 500 kW - 1100 kW R134a INSTALLATION & MAINTENANCE OPTICHILL Chillers AB OUT AIR ED AL E About Airedale Products & Customer Services WARRANTY, COMMISSIONING & MAINTENANCE The equipment carries the Airedale unit parts and labour warranty in respect of non-consumable parts, for a period of 12 months from the date of commissioning or 18 months from the date of despatch which ever is the sooner. (Excludes the cost of any specialist access or lifting equipment.) Commissioning will be carried out by Airedale International Air Conditioning Ltd or an approved Airedale commissioning company. To further protect your investment in Airedale products, Airedale Service can provide full commissioning services, comprehensive maintenance packages and service cover 24 hours a day, 365 days a year (UK mainland). For a free quotation contact Airedale Service or your local Sales Engineer. All Airedale products are designed in accordance with EU Directives regarding prevention of build up of water, associated with the risk of contaminants such as Legionella. Where applicable, effective removal of condensate is achieved by gradient drainage to outlets and where used, humidification systems produce sterile, non-toxic steam during normal operation. For effective prevention of such risk it is necessary that the equipment is maintained in accordance with Airedale recommendations. CAUTION Warranty cover is not a substitute for Maintenance. Warranty cover is conditional to maintenance being carried out in accordance with the recommendations provided during the warranty period. Failure to have the maintenance procedures carried out will invalidate the warranty and any liabilities by Airedale International Air Conditioning Ltd. SPARES A spares list for 1, 3 and 5 years will be supplied with every unit and is also available from our Spares department on request. TRAINING As well as our comprehensive range of products, Airedale offers a modular range of Refrigeration and Air Conditioning Training courses, for further information please contact Airedale. CUSTOMER SERVICES For further assistance, please e-mail: [email protected] or telephone: Custom er Services UK Sales Enquiries International Enquiries Spares Hot Line Airedale Service Technical Support Training Enquiries + 44 (0) 113 238 7789 + 44 (0) 113 239 1000 + 44 (0) 113 238 7878 + 44 (0) 113 239 1000 + 44 (0) 113 239 1000 + 44 (0) 113 239 1000 [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] For information, visit us at our Web Site: www.airedale.com Legal Notices AIAC Ltd endeavours to ensure that the information in this document is correct and fairly stated, but none of the statements are to be relied upon as a statement or representation of fact. AIAC Ltd does not accept liability for any error or omission, or for any reliance placed on the information contained in this document. The development of Airedale products and services is continuous and the information in this document may not be up to date. It is important to check the current position with AIAC Ltd at the address stated. This document is not part of a contract or licence unless expressly agreed. No part of this document may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or information storage and retrieval systems, for any purpose other than the purchaser’s personal use, without the express written permission of AIAC Ltd. 2012 Airedale International Air Conditioning Limited. All rights reserved. Printed in the UK. 2 Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL CONTENT S Contents General Statement 4 Warranty 5 General Description 6 Unit identification Introduction Features Optional extras 6 6 7 10 Dimensional Data 12 Standard Units Units fitted with optional pump package Plenum options 12 14 16 Installation Data 17 Weights, point loadings & centre of gravity (C of G) - no pumps Weights - with optional pumps (guidance) Unit Lifting Anti vibration mounting (optional) Positioning Water system Grooved & clamped type connection Refrigeration schematic Standard recommended installation Glycol data Pumps options Mechanical data - high efficiency Mechanical data - high efficiency plus Electrical Interconnecting wiring Electrical data - high efficiency Electrical data - high efficiency plus Controls 17 19 20 21 22 23 23 24 24 26 27 28 28 30 31 32 36 38 Temperature control General description Operation Setting up Viewing unit operating status Alarms Commissioning Data General data Oil & refrigerant charges - high efficiency Oil & refrigerant charges - high efficiency plus Waterside pressure drop (kPa) Pump packages (optional extras) Electrical data Pre commissioning checklist Commissioning checklist Maintenance General maintenance Compressor maintenance Parts Identification 38 39 39 40 41 42 43 43 44 44 46 47 50 52 54 55 56 57 58 Chillers Installation & Maintenance : 6564868 09/2012 3 OPTICHILL Chillers General Statement IMPORTANT The information contained in this manual is critical to the correct operation and maintenance of the unit and should be read by all persons responsible for the installation, commissioning and maintenance of this Airedale unit. SAFETY The equipment has been designed and manufactured to meet international safety standards but, like any mechanical/electrical equipment, care must be taken if you are to obtain the best results. CAUTION 1 Installation, service and maintenance of Airedale equipment should only be carried out by technically trained competent personnel. CAUTION 2 When working with any air conditioning units ensure that the electrical isolator is switched off prior to servicing or repair work and that there is no power to any part of the equipment. 3 Also ensure that there are no other power feeds to the unit such as fire alarm circuits, BMS circuits etc. 4 Electrical installation commissioning and maintenance work on this equipment should be undertaken by competent and trained personnel in accordance with local relevant standards and codes of practice. 5 The refrigerant used in this range of products is classified under the COSHH regulations as an irritant, with set Occupational Exposure Levels (OEL) for consideration if this plant is installed in confined or poorly ventilated areas. 6 A full hazard data sheet in accordance with COSHH regulations is available should this be required. SPARES For ease of identification when ordering spares or contacting Airedale about your unit, please quote the unit type, unit serial number and the date of manufacture, which can be found on the unit serial plate. A spares list for 1, 3 and 5 years will be supplied with every unit and is also available from our Spares department on request. SERIAL PLATE The serial plate can be located to the inside of the control panel door, refer to Parts Identification, on page 58. UK Office Unit/Gerät/Unite Serial/Serie/Serie OPC500HED-8 81543668-001 (63091072) Manufactured/Hergestellt/Fabriqué Supply/Spannung/Alimentation 24/01/2007 400 V 3 PH 50 Hz Fuse/Hauptsicherung/Fusibles 25.0 A Test Pressure Prüfdruck Pression d’essai 27.0 BAR Refrigerant & Charge Kältemittel und Füllung Refrigerant & Charge Max. operating pressure Betriebsdruck (Maximal) Pression de marche (Maximum) N.B. No: 0086 www.airedale.com 4 + 44 113 2391000 Chillers Installation & Maintenance : 6564868 09/2012 + 44 113 2507219 Chillers OPTICHILL Warranty GENERAL To be read in conjunction with Airedale International Air Conditioning Ltd standard Conditions of Sale and any related quotation. The equipment carries Airedale’s standard Parts (non consumable) & Labour warranty for a period of 12 months from the date of commissioning or 18 months from the date of despatch, which ever is the sooner. Commissioning must be carried out by Airedale or an approved Airedale company. WARRANTY IS ONLY VALID IN THE EVENT THAT: 1 In the period between delivery and commissioning the equipment: o is properly protected & serviced o water flow safety devices are in place and fully operational 2 The equipment is serviced and maintained by Airedale or an approved Airedale company in accordance with the Installation & Maintenance manual provided, during the Warranty Period. In the event of a problem being reported, Airedale will cover the full cost of rectification (excluding costs for any specialist access or lifting equipment) if warranty is valid under these conditions. Any spare part supplied by Airedale under the warranty shall be warranted for the unexpired period of the warranty or 3 months from delivery whichever period is the longer, with the exception of compressors on which a further 12 months warranty is granted. PROCEDURE The on site contractor or service company place an official order on Airedale for the replacement part including site labour if required, Airedale will acknowledge this order with detailed prices for components, travel and labour rates Should warranty be accepted, following inspection of the faulty component, a credit note will be issued against the invoice raised in line with the acknowledgement Should warranty be refused the invoice raised against the acknowledgement becomes payable on normal terms Airedale reserves the right to carry out site warranty labour work using their own direct labour or by sub contracting to an approved company of their choice EXCLUSIONS Warranty may be refused for the following reasons: Misapplication of product or component Incorrect site installation Incomplete commissioning documentation Inadequate site installation Inadequate site maintenance Damage caused by mishandling Replaced part being returned damaged without explanation Unnecessary delays incurred in return of defective component GENERAL Dead on arrival or manufacturing defects are the responsibility of Airedale and should be reported immediately. In the event of a warranty failure, dead on arrival or manufacturing defect, the Airedale Service department should be contacted and on receipt of an order, an Airedale engineer (or representative) will be directed to site as soon as possible. RETURNS ANALYSIS All faulty components returned under warranty are analysed on a monthly basis as a means of verifying component and product reliability as well as supplier performance. It is important that all component failures are reported correctly. Chillers Installation & Maintenance : 6564868 09/2012 5 OPTICHILL Chillers General Description UNIT IDENTIFICATION OPC OPC OptiChill Screw Chiller 500 - 1100 Model Size (Expressed as Nominal Cooling in kW) HED HEDQ HE+D HE+DQ High Efficiency - Dual Circuit High Efficiency - Dual Circuit - Quiet High Efficiency Plus - Dual Circuit High Efficiency Plus - Dual Circuit - Quiet 8 - 20 Number of Fans INTRODUCTION 800 HED 12 The Airedale range of OptiChill air cooled liquid screw chillers covers the nominal capacity range 500kW to 1100kW in 13 models sizes. Each model size is offered in High Efficiency (HE) or High Efficiency Plus (HE+) and available as Standard (D) or Quiet (DQ) sound level variations to meet a wide range of applications. Attention has been placed on offering a low energy high output performance and flexible product, while keeping the sound and footprint to an absolute minimum. CE DIRECTIVE Airedale certify that the equipment detailed in this manual conforms with the following EC Directives: Electromagnetic Compatibility Directive (EMC) Low Voltage Directive (LVD) Machinery Directive (MD) Pressure Equipment Directive (PED) 89/336/EEC 73/23/EEC 89/392/EEC in the version 98/37/EC 97/23/EC To comply with these directives appropriate national & harmonised standards have been applied. These are listed on the Declaration of Conformity, supplied with each product. REFRIGERANTS 6 The range has been designed and optimised for operation with ozone benign R134a refrigerant. Chillers Installation & Maintenance : 6564868 09/2012 ● Standard ○ Optional Extra HEDQ High Efficiency - Quiet HE+D High Efficiency Plus HE+DQ High Efficiency Plus - Quiet - ● - ● ● ● ● ● ● ● ● ● Standard Size Larger Size Standard Size Larger Size ● ● - ● ● ● ● - ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● - Not available 7 Construction Acoustically lined compressor enclosure Standard Height Condenser Fan Discharge Plenum (300mm) Extended Condenser Fan Discharge Plenum (800mmm) Evaporator / Waterside Shell & Tube evaporator with immersion heater & thermostat Grooved water connections and counter pipe assembly Flow switch Waterside Differential Pressure Switch Pumps - Fixed Speed Low Energy Pumps - Variable Speed incorporating Electronic Flow Metering System Condenser Condenser Coils - Enhanced Corrosion Resistant Condenser Coils Coil Guards Head Pressure Control - Voltage Regulated Head Pressure Control - Electronically Commutated (EC) Regulated Low speed Axial condenser fan with Sickle blades Extra Low speed Axial condenser fan with Sickle blades Refrigeration Twin screw compressors with low current Star/Delta Start Dual independent refrigeration circuits Electronic Expansion Valve (EEV) Economiser with dedicated EEV Maintainable Dual Pressure relief valve assembly Discharge line mufflers and noise traps Liquid line sight glass Liquid and Discharge line ball valves Large capacity filter drier with replaceable cores Manual reset HP/LP Switch (LP via microprocessor) Suction and liquid pressure transducers Anti Vibration Mounts Leak Detection System Electrical Emergency stop Individual door isolated mains power compartments for each refrigeration CCT, fans & pump option Dedicated bus-bar chamber for incoming 3-phase & earth mains power supply Closed transition Star/Delta Start Connections for External Trace Heating Power Factor Correction Controls Microprocessor Controller Energy Manager Electronic compressor protection module with phase & rotation protection Phase Rotation Protection Sequence Control - Chiller Sequence Manager Remote Setpoint Adjust 0-10 V Signal BMS interface Card - - ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● OPTICHILL Chillers Installation & Maintenance : 6564868 08/2008 HED High Efficiency Chillers FEATURES OPTICHILL Chillers General Description STANDARD FEATURES Construction The base is fabricated from galvanised steel to ensure a rigid, durable, weatherproof construction. Unit panels are manufactured from galvanised sheet steel coated with epoxy baked powder paint to provide a durable and weatherproof finish. Standard unit colour is Light Grey (RAL 7035). Compressors and evaporator are mounted on a rigid galvanised heavy-duty sub frame. Fully weatherproofed electrical panels are situated at one end of the unit. STANDARD FEATURES Compressor Twin screw semi hermetic compressors comprising: Electronic Protection Module featuring: Motor, discharge gas and oil monitoring Rotation direction protection Phase failure protection Low current Star/Delta Start Internal pressure relief Discharge non return valve Oil separator Oil sight glass Oil heater Slide valve stepped capacity control Suction gas motor cooling The compressors are mounted to the rigid galvanised heavy duty sub-frame with the use of vibration reducing isolation. Liquid injection is not required under normal operating conditions, leading to an increase in cooling and efficiency Closed transition Star/Delta compressor start is available as an optional extra. Refrigeration 8 Each refrigeration circuit is supplied with the following: Full operating charge of R134a Electronic Expansion Valves (EEV) Discharge line ball valve Liquid line ball valve Large capacity filter drier with replaceable cores Liquid line sight glass Low pressure switch with Auto reset High pressure switch with manual reset Suction and liquid pressure transducers Discharge line mufflers (DQ Models) Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL General Description STANDARD FEATURES As standard, the capacity control. Controls microprocessor controller can provide 8 stages of Optionally, the controller is designed to provide capabilities for; Building Management Systems (BMS) Sequencing (Master/Slave and Run/Standby) to meet all your system requirements, please specify at order. Unit initial set up details can be found in the Controls section. CAUTION When adding to an existing network, please consult Airedale to ensure strategy compatibility. A weatherproof electrical power and controls panel is situated at the end of the unit and contains: Electrical CAUTION Individual mains power compartments for each refrigeration circuit refer to Separate door locking electrical isolation for each Interconnecting wiring, mains compartment on page 31 Dedicated bus-bar chamber for connection of incoming 3phase and earth mains power supply Emergency Stop fitted to controls compartment door Separate, fully accessible, controls compartment, allowing adjustment of control set points whilst the unit is operational Circuit breakers for protection of all major unit components Phase rotation relay incorporating phase loss protection (compressor module) A fused and isolated electrical supply of the appropriate phase, frequency and voltage should be installed. The electrical power and control panel is wired to the latest European standards and codes of practice. Mains supply is 3 phase and a neutral is not required, refer to Interconnecting wiring, on page 31. Separate 230V permanent supply is required for the controls and safety features. Electrical terminals for external evaporator pipework trace heating (230V/500W) are provided. For further electrical information refer to Installation Data, on page 30. Chillers Installation & Maintenance : 6564868 09/2012 9 OPTICHILL Chillers General Description OPTIONAL EXTRAS Loose Item Factory Fitted Power Factor Correction Electronically Commutated (EC) Fan Motor Energy Manager Pump - Inverter Driven - Variable Speed for Constant Water Flow Pump - ac Motor - Fixed Speed Corrosion Resistant Coated Coils Coil Guards Discharge Air Plenum Condenser Fan Extended Discharge Air Plenum Condenser Fan Maintainable Dual Pressure Relief Valve R134a Leak Detection System Closed Transition Star/Delta Compressor Start Evaporator Differential Pressure Sensor Remote Setpoint Adjust BMS Interface Card Commissioning Chillerguard® Maintenance(1) (1) 10 - Instructions supplied with item It is only possible to set up a sequencing following completion of interconnecting communication wiring. Airedale Service can arrange sequence setup on request (UK Mainland). CAUTION Optional Unit Cover Anti Vibration Mounts Flow Switch Chiller Sequence Manager UK Mainland Sites Chillers Installation & Maintenance : 6564868 09/2012 - Standard feature to HEDQ, HE+D & HE+DQ Assembly Instructions supplied with item - Refer to Commissioning Data, on page 50 for details For details and a competitive quotation, contact Airedale Service. Chillers OPTICHILL Notes: Chillers Installation & Maintenance : 6564868 09/2012 11 OPTICHILL Chillers Dimensional Data The following information is for general guidance; refer to the certified drawings provided for installation. IMPORTANT STANDARD UNITS 8 - 10 Fan Units (mm) (8) (9) 50 2100 (10) 50 500 (10) H G1 G1 L (2) (1) (3) (3) A (1) (6) (4) (5) (6) (7) D 90 90 F E B C 12 - 20 Fan Units (mm) (8) (9) 50 2100 (10) 50 500 G1 (10) H G2 J (2) (1) (3) (3) A (1) (6) (4) (5) (7) (6) 90 D 90 12 F E B Chillers Installation & Maintenance : 6564868 09/2012 C K L Chillers OPTICHILL Dimensional Data HIGH EFFICIENCY - STANDARD UNITS OPC500HED8 OPC525HED8 OPC550HED8 OPC600HED10 OPC650HED10 OPC700HED12 OPC750HED12 OPC800HED12 OPC850HED12 OPC900HED14 OPC950HED14 OPC1000HED16 OPC1100HED16 mm mm mm mm mm mm mm mm mm mm mm mm mm A 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 B 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 C 4675 4675 4675 5675 5675 7100 7100 7100 7100 8100 8100 9100 9100 D 460 460 460 460 510 510 510 510 510 510 510 510 510 E 1056 1056 1056 1556 1582 2730 2730 2730 2304 2304 2304 3304 3304 F 2412 2412 2412 2412 2360 2360 2360 2360 3210 3210 3210 3210 3210 G1 1250 1250 1250 1750 1750 1850 1850 1850 1850 2000 2000 2875 2875 G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A H 1250 1250 1250 1250 1250 1200 1200 1200 1200 1400 1400 1400 1400 J N/A N/A N/A N/A N/A 1175 1175 1175 1175 1400 1400 1400 1400 K N/A N/A N/A N/A N/A 1775 1775 1775 1775 2000 2000 2325 2325 L 425 425 425 425 425 600 600 600 600 800 800 600 600 (10) DN150 PN16 DN150 PN16 DN150 PN16 DN150 PN16 DN150 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 OPC500HEDQ10 OPC525HEDQ10 OPC550HEDQ10 OPC600HEDQ10 OPC650HEDQ10 OPC700HEDQ14 OPC750HEDQ14 OPC800HEDQ14 OPC850HEDQ14 OPC900HEDQ16 OPC950HEDQ16 OPC1000HEDQ18 OPC1100HEDQ18 mm mm mm mm mm mm mm mm mm mm mm mm mm A 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 B 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 C 5675 5675 5675 5675 5675 8100 8100 8100 8100 9100 9100 10100 10100 D 460 460 460 460 460 510 510 510 510 510 510 510 510 E 1556 1556 1556 1556 1556 2730 2730 2304 2304 3304 3304 3304 3304 F 2412 2412 2412 2412 2412 2360 2360 3210 3210 3210 3210 3210 3210 G1 1750 1750 1750 1750 1750 2000 2000 2000 2000 2875 2875 3000 3000 G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A H 1250 1250 1250 1250 1250 1400 1400 1400 1400 1400 1400 1400 1400 J N/A N/A N/A N/A N/A 1400 1400 1400 1400 1400 1400 1400 1400 K N/A N/A N/A N/A N/A 2000 2000 2000 2000 2325 2325 3000 3000 L 425 425 425 425 425 800 800 800 800 600 600 800 800 (10) DN150 PN16 DN150 PN16 DN150 PN16 DN150 PN16 DN150 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 HIGH EFFICIENCY PLUS - STANDARD UNITS OPC500HE+D8 OPC525HE+D10 OPC550HE+D10 OPC600HE+D10 OPC650HE+D10 OPC700HE+D12 OPC750HE+D12 OPC800HE+D14 OPC850HE+D14 OPC900HE+D16 OPC950HE+D18 OPC1000HE+D18 OPC1100HE+D18 mm mm mm mm mm mm mm mm mm mm mm mm mm A 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 B 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 C 4675 5675 5675 5675 5675 7100 7100 8100 8100 9100 10100 10100 10100 D 510 510 510 510 510 510 510 510 510 510 510 510 510 E 1082 1582 1582 1582 1157 2304 2304 2304 2304 3304 3304 3304 3304 F 2360 2360 2360 2360 3210 3210 3210 3210 3210 3210 3210 3210 3210 G1 1250 1750 1750 1750 1750 1850 1850 2000 2000 2875 3000 3000 3000 G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A H 1250 1250 1250 1250 1250 1200 1200 1400 1400 1400 1400 1400 1400 J N/A N/A N/A N/A N/A 1175 1175 1400 1400 1400 1400 1400 1400 K N/A N/A N/A N/A N/A 1775 1775 2000 2000 2325 3000 3000 3000 L 425 425 425 425 425 600 600 800 800 600 800 800 800 (10) DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 OPC500HE+DQ12 OPC525HE+DQ12 OPC550HE+DQ12 OPC600HE+DQ12 OPC650HE+DQ12 OPC700HE+DQ14 OPC750HE+DQ16 OPC800HE+DQ16 OPC850HE+DQ18 OPC900HE+DQ20 OPC950HE+DQ20 OPC1000HE+DQ20 OPC1100HE+DQ20 mm mm mm mm mm mm mm mm mm mm mm mm mm A 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 B 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 2200 C 7100 7100 7100 7100 7100 8100 9100 9100 10100 11100 11100 11100 11100 D 510 510 510 510 510 510 510 510 510 510 510 510 510 E 2730 2730 2730 2730 2730 2304 3304 3304 3304 4304 4304 4304 4304 F 2360 2360 2360 2360 2360 3210 3210 3210 3210 3210 3210 3210 3210 G1 1850 1850 1850 1850 1850 2000 2875 2875 3000 2000 2000 2000 2000 G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A 2000 2000 2000 2000 H 1200 1200 1200 1200 1200 1400 1400 1400 1400 1400 1400 1400 1400 J 1175 1175 1175 1175 1175 1400 1400 1400 1400 1400 1400 1400 1400 K 1775 1775 1775 1775 1775 2000 2325 2325 3000 2700 2700 2700 2700 L 600 600 600 600 600 800 600 600 800 1100 1100 1100 1100 (10) DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) Mains Electric Isolator(s), for unit isolation refer to (6). Emergency Stop. Mains Electric Panel(s), for unit isolation refer to (6). Microprocessor Control Panel. Compressor Enclosure (DQ Models Only). Mains Cable Entry to Busbar, unit incoming mains isolation supplied by others. Busbar Chamber. Lifting Lugs (removable). 20mm Ø Mounting Holes: 8 - 10 Fan Unit x8 12 - 18 Fan Unit x 10 20 Fan Unit x 12 Water Connections. Chillers Installation & Maintenance : 6564868 09/2012 13 OPTICHILL Chillers Dimensional Data The following information is for general guidance; refer to the certified drawings provided for installation. IMPORTANT UNITS FITTED WITH OPTIONAL PUMP PACKAGE 8 - 12 Fan Units (mm) (8) (9) 50 2100 (1) 50 (10) (10) 500 H G1 J K L (12) 275 (2) (1) (3) (3) (1) (11) A (6) (4) (5) (7) (6) D E 90 90 F 370 2200 C1 B 1400 C Pump package assembly and connecting evaporator pipework supplied loose. IMPORTANT 14 - 20 Fan Units (mm) (8) (9) 50 2100 (1) (10) 50 500 G1 G2 (10) H J K (12) L (2) (1) (3) (3) A (1) (6) (4) (5) (7) (6) D 90 90 2000 (11) F E 370 C B IMPORTANT 14 Connecting evaporator pipework supplied loose. Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL Dimensional Data HIGH EFFICIENCY - WITH OPTIONAL PUMP PACKAGE OPC500HED8 OPC525HED8 OPC550HED8 OPC600HED10 OPC650HED10 OPC700HED12 OPC750HED12 OPC800HED12 OPC850HED12 OPC900HED14 OPC950HED14 OPC1000HED16 OPC1100HED16 mm mm mm mm mm mm mm mm mm mm mm mm mm A 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 B 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 C 6075 6075 6075 7075 7075 8500 8500 8500 8500 8100 8100 9100 9100 C1 4675 4675 4675 5675 5675 7100 7100 7100 7100 N/A N/A N/A N/A D 460 460 460 460 510 510 510 510 510 510 510 510 510 E 1056 1056 1056 1556 1582 2730 2730 2730 2304 2304 2304 3304 3304 F 4300 4300 4300 4800 4770 5050 5050 5050 5477 5075 5075 5075 5075 G1 1250 1250 1250 1750 1750 1850 1850 1850 1850 2000 2000 2875 2875 G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A H 1250 1250 1250 1250 1250 1200 1200 1200 1200 1400 1400 1400 1400 J N/A N/A N/A N/A N/A 1175 1175 1175 1175 1400 1400 1400 1400 K N/A N/A N/A N/A N/A 1775 1775 1775 1775 2000 2000 2325 2325 L 1550 1550 1550 1550 1550 1725 1725 1725 1725 800 800 600 600 (10) DN150 PN16 DN150 PN16 DN150 PN16 DN150 PN16 DN150 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 OPC500HEDQ10 OPC525HEDQ10 OPC550HEDQ10 OPC600HEDQ10 OPC650HEDQ10 OPC700HEDQ14 OPC750HEDQ14 OPC800HEDQ14 OPC850HEDQ14 OPC900HEDQ16 OPC950HEDQ16 OPC1000HEDQ18 OPC1100HEDQ18 mm mm mm mm mm mm mm mm mm mm mm mm mm A 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 B 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 C 7075 7075 7075 7075 7075 8100 8100 8100 8100 9100 9100 10100 10100 C1 5675 5675 5675 5675 5675 N/A N/A N/A N/A N/A N/A N/A N/A D 460 460 460 460 460 510 510 510 510 510 510 510 510 E 1556 1556 1556 1556 1556 2730 2730 2304 2304 3304 3304 3304 3304 F 4800 4800 4800 4800 4800 4650 4650 5075 5075 5075 5075 6075 6075 G 1750 1750 1750 1750 1750 2000 2000 2000 2000 2875 2875 3000 3000 G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A H 1250 1250 1250 1250 1250 1400 1400 1400 1400 1400 1400 1400 1400 J N/A N/A N/A N/A N/A 1400 1400 1400 1400 1400 1400 1400 1400 K N/A N/A N/A N/A N/A 2000 2000 2000 2000 2325 2325 3000 3000 L 1550 1550 1550 1550 1550 800 800 800 800 600 600 800 800 (10) DN150 PN16 DN150 PN16 DN150 PN16 DN150 PN16 DN150 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 HIGH EFFICIENCY PLUS - WITH OPTIONAL PUMP PACKAGE OPC500HE+D8 OPC525HE+D10 OPC550HE+D10 OPC600HE+D10 OPC650HE+D10 OPC700HE+D12 OPC750HE+D12 OPC800HE+D14 OPC850HE+D14 OPC900HE+D16 OPC950HE+D18 OPC1000HE+D18 OPC1100HE+D18 mm mm mm mm mm mm mm mm mm mm mm mm mm A 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 B 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 C 6075 7075 7075 7075 7075 8500 8500 8100 8100 9100 10100 10100 10100 C1 4675 5675 5675 5675 5675 7100 7100 N/A N/A N/A N/A N/A N/A D 510 510 510 510 510 510 510 510 510 510 510 510 510 E 1082 1582 1582 1582 1157 2304 2304 2304 2304 3304 3304 3304 3304 F 4274 4770 4770 4770 5200 5477 5477 5075 5075 5075 6075 6075 6075 G 1250 1750 1750 1750 1750 1850 1850 2000 2000 2875 3000 3000 3000 G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A H 1250 1250 1250 1250 1250 1200 1200 1400 1400 1400 1400 1400 1400 J N/A N/A N/A N/A N/A 1175 1175 1400 1400 1400 1400 1400 1400 K N/A N/A N/A N/A N/A 1775 1775 2000 2000 2325 3000 3000 3000 L 1550 1550 1550 1550 1550 1725 1725 800 800 600 800 800 800 (10) DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 OPC500HE+DQ12 OPC525HE+DQ12 OPC550HE+DQ12 OPC600HE+DQ12 OPC650HE+DQ12 OPC700HE+DQ14 OPC750HE+DQ16 OPC800HE+DQ16 OPC850HE+DQ18 OPC900HE+DQ20 OPC950HE+DQ20 OPC1000HE+DQ20 OPC1100HE+DQ20 mm mm mm mm mm mm mm mm mm mm mm mm mm A 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 2600 B 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 2570 C 8500 8500 8500 8500 8500 8100 9100 9100 10100 11100 11100 11100 11100 C1 7100 7100 7100 7100 7100 N/A N/A N/A N/A N/A N/A N/A N/A D 510 510 510 510 510 510 510 510 510 510 510 510 510 E 2730 2730 2730 2730 2730 2304 3304 3304 3304 4304 4304 4304 4304 F 5050 5050 5050 5050 5050 5075 5075 5075 6075 6075 6075 6075 6075 G 1850 1850 1850 1850 1850 2000 2875 2875 3000 2000 2000 2000 2000 G2 N/A N/A N/A N/A N/A N/A N/A N/A N/A 2000 2000 2000 2000 H 1200 1200 1200 1200 1200 1400 1400 1400 1400 1400 1400 1400 1400 J 1175 1175 1175 1175 1175 1400 1400 1400 1400 1400 1400 1400 1400 K 1775 1775 1775 1775 1775 2000 2325 2325 3000 2700 2700 2700 2700 L 1725 1725 1725 1725 1725 800 600 600 800 1100 1100 1100 1100 (10) DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) Mains Electric Isolator(s), for unit isolation refer to (6). Emergency Stop. Mains Electric Panel(s), for unit isolation refer to (6). Microprocessor Control Panel. Compressor Enclosure (DQ Models Only). Mains Cable Entry to Busbar, unit incoming mains isolation supplied by others. Busbar Chamber. Lifting Lugs (removable). 20mm Ø Mounting Holes: 8 - 10 Fan Unit x 8 + 2 (Pump Package) 12 Fan Unit x 10 + 2 (Pump Package) Water Connections. Pump package including connecting evaporator pipework. Pump Controls Panel, for unit isolation refer to (6). 14 - 18 Fan Unit 20 Fan Unit x 10 x 12 Chillers Installation & Maintenance : 6564868 09/2012 15 OPTICHILL Dimensional Data PLENUM OPTIONS Standard Discharge Plenum Option (mm) 2600 Extended Discharge Plenum Option (mm) 3100 (1) 16 For plenum weights, please contact Airedale. Chillers Installation & Maintenance : 6564868 09/2012 Chillers Chillers OPTICHILL Installation Data WEIGHTS, POINT LOADINGS & CENTRE OF GRAVITY (C OF G) - NO PUMPS High Efficiency 2 1 L1 L2 L3 L4 = (C of G) R1 R2 R3 R4 1 2 L1 L2 L3 L4 L5 L6 = C of G R1 R2 R3 R4 R5 R6 OPC500HED8 OPC525HED8 OPC550HED8 OPC600HED10 OPC650HED10 OPC700HED12 OPC750HED12 OPC800HED12 OPC850HED12 OPC900HED14 OPC950HED14 OPC1000HED16 OPC1100HED16 L1 650 660 660 750 760 760 810 810 820 820 830 900 900 L4 470 470 470 370 380 760 810 810 820 860 870 910 910 Point Loadings (kg) L5 L6 R1 R2 (1) (1) 830 860 (1) (1) 830 870 (1) (1) 830 870 (1) (1) 920 1080 (1) (1) 1010 1190 360 (2) 950 800 380 (2) 1010 840 390 (2) 1010 850 390 (2) 1070 890 370 (2) 1040 1130 380 (2) 1050 1140 490 (2) 1130 1140 490 (2) 1130 1140 R3 850 850 860 950 1040 1040 1100 1100 1170 1240 1250 1260 1260 R4 590 590 590 450 500 950 1010 1010 1070 1100 1110 1140 1140 R5 (1) (1) (1) (1) (1) 450 480 480 510 480 480 610 610 R6 (1) (1) (1) (1) (1) (2) (2) (2) (2) (2) (2) (2) (2) Operating Weight (kg) 5600 5640 5650 6170 6570 7530 8000 8020 8330 8900 8990 9490 9490 C of G (mm) 1 1220 1220 1220 1205 1245 1220 1215 1215 1235 1225 1225 1220 1220 2 2225 2225 2230 2495 2515 3130 3230 3225 3250 3510 3525 4290 4295 OPC500HEDQ10 OPC525HEDQ10 OPC550HEDQ10 OPC600HEDQ10 OPC650HEDQ10 OPC700HEDQ14 OPC750HEDQ14 OPC800HEDQ14 OPC850HEDQ14 OPC900HEDQ16 OPC950HEDQ16 OPC1000HEDQ18 OPC1100HEDQ18 L1 L2 L3 L4 800 940 820 390 800 940 830 390 800 950 830 400 800 950 830 400 810 950 830 400 790 860 940 830 840 910 1000 880 850 930 1010 900 850 930 1010 900 930 940 1040 940 940 950 1050 950 970 1040 1110 1010 970 1050 1110 1010 Point Loadings (kg) L5 L6 R1 R2 (1) (1) 960 1130 (1) (1) 960 1140 (1) (1) 970 1140 (1) (1) 970 1140 (1) (1) 970 1140 360 (2) 970 1050 390 (2) 1020 1110 390 (2) 1070 1170 390 (2) 1070 1170 510 (2) 1160 1170 510 (2) 1170 1180 540 (2) 1180 1280 540 (2) 1190 1280 R3 990 1000 1000 1000 1000 1150 1210 1270 1280 1290 1300 1360 1360 R4 470 470 480 480 480 1020 1080 1130 1130 1170 1180 1240 1240 R5 (1) (1) (1) (1) (1) 450 470 490 490 630 630 660 670 R6 (1) (1) (1) (1) (1) (2) (2) (2) (2) (2) (2) (2) (2) Operating Weight (kg) 6500 6530 6570 6570 6580 8420 8910 9210 9220 9780 9860 10390 10420 C of G (mm) 1 1200 1200 1200 1195 1195 1205 1200 1220 1220 1215 1210 1205 1205 2 2520 2520 2520 2520 2525 3440 3510 3525 3525 4295 4305 4485 4485 (1) (2) (3) (4) L2 L3 680 670 690 680 690 680 880 770 900 790 630 830 680 880 680 880 690 900 890 970 900 980 910 1000 910 1000 Only 8 fixing and loading points to this model. Only 10 fixing and loading points to this model. Based on standard unit, for units fitted with options, please contact Airedale. Operating weight includes refrigerant charge and system water volume. Chillers Installation & Maintenance : 6564868 09/2012 17 OPTICHILL Chillers Installation Data WEIGHTS, POINT LOADINGS & CENTRE OF GRAVITY (C OF G) - NO PUMPS High Efficiency Plus 2 1 L1 L2 L3 L4 = (C of G) R1 R2 R3 R4 1 2 L1 L2 L3 L4 L5 L6 = C of G R1 R2 R3 R4 R5 R6 OPC500HE+D8 OPC525HE+D10 OPC550HE+D10 OPC600HE+D10 OPC650HE+D10 OPC700HE+D12 OPC750HE+D12 OPC800HE+D14 OPC850HE+D14 OPC900HE+D16 OPC950HE+D18 OPC1000HE+D18 OPC1100HE+D18 L1 L2 L3 670 700 690 760 890 780 760 890 780 760 900 790 770 910 800 770 640 840 820 690 900 810 880 960 810 880 960 890 900 990 920 990 1050 920 1000 1050 920 1000 1060 L4 480 370 370 370 380 770 820 850 850 900 960 960 960 Point Loadings (kg) L5 L6 R1 R2 (1) (1) 920 960 (1) (1) 1000 1180 (1) (1) 1000 1180 (1) (1) 1010 1180 (1) (1) 1070 1260 360 (2) 1010 840 390 (2) 1060 890 370 (2) 1030 1120 370 (2) 1030 1120 480 (2) 1120 1130 510 (2) 1140 1230 520 (2) 1140 1240 520 (2) 1150 1240 R3 940 1030 1040 1040 1110 1100 1160 1220 1230 1240 1310 1310 1310 R4 650 490 490 500 530 1010 1060 1090 1090 1130 1190 1190 1200 R5 (1) (1) (1) (1) (1) 480 510 470 470 610 640 640 640 R6 (1) (1) (1) (1) (1) (2) (2) (2) (2) (2) (2) (2) (2) Operating Weight (kg) 6010 6500 6510 6550 6830 7820 8300 8800 8810 9390 9940 9970 10000 C of G (mm) 1 1265 1245 1245 1245 1270 1245 1235 1230 1230 1220 1215 1215 1215 2 2225 2510 2515 2515 2530 3160 3250 3520 3520 4280 4480 4480 4480 OPC500HE+DQ12 OPC525HE+DQ12 OPC550HE+DQ12 OPC600HE+DQ12 OPC650HE+DQ12 OPC700HE+DQ14 OPC750HE+DQ16 OPC800HE+DQ16 OPC850HE+DQ18 OPC900HE+DQ20 OPC950HE+DQ20 OPC1000HE+DQ20 OPC1100HE+DQ20 L1 L2 L3 L4 740 620 810 740 750 630 820 750 750 630 820 750 750 630 820 750 750 630 820 750 800 870 950 840 920 930 1030 930 920 930 1030 930 950 1020 1080 990 560 640 1090 1060 570 640 1100 1070 570 640 1100 1070 570 640 1100 1080 Point Loadings (kg) L5 L6 R1 R2 350 (2) 930 780 360 (2) 940 780 360 (2) 940 790 360 (2) 940 790 360 (2) 940 790 370 (2) 1020 1110 500 (2) 1150 1160 500 (2) 1150 1160 530 (2) 1160 1260 910 590 690 770 920 600 690 780 920 600 690 780 920 600 690 780 R3 1020 1020 1030 1030 1030 1210 1280 1280 1330 1320 1330 1340 1340 R4 930 940 940 940 940 1070 1160 1160 1210 1290 1300 1310 1310 R5 440 450 450 450 450 470 620 620 650 1110 1120 1120 1120 R6 (2) (2) (2) (2) (2) (2) (2) (2) (2) 720 730 730 730 Operating Weight (kg) 7360 7440 7460 7460 7460 8710 9680 9680 10180 10750 10850 10870 10880 C of G (mm) 1 1220 1220 1220 1220 1220 1225 1215 1215 1210 1205 1200 1200 1200 2 3215 3215 3220 3215 3220 3455 4300 4295 4480 5265 5280 5275 5280 (1) (2) (3) (4) 18 Only 8 fixing and loading points to this model. Only 10 fixing and loading points to this model. Based on standard unit, for units fitted with options, please contact Airedale. Operating weight includes refrigerant charge and system water volume. Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL Installation Data WEIGHTS - WITH OPTIONAL PUMPS (GUIDANCE) CAUTION Due to the number of different pump options available, the following table is provided as a guide to the MAXIMUM weight of models with optional pumps fitted. Once selection has been made, it is important to consult Airedale for the specific details at time of enquiry to ensure lifting and support arrangements are sufficient. Point Loadings and AV selection will be provided separately. OPC750HED12 OPC800HED12 OPC850HED12 OPC900HED14 8210 8610 8220 8630 8400 8940 8943 9483 9023 9550 9570 9573 10090 10090 kg kg 6182 6422 6202 6462 6232 6472 6722 6992 7006 7426 7976 8386 8522 8922 8532 8942 8712 9252 9250 9790 9330 9874 9894 9880 10414 10414 OPC500HEDQ10 OPC525HEDQ10 OPC550HEDQ10 OPC600HEDQ10 OPC650HEDQ10 OPC700HEDQ14 OPC750HEDQ14 OPC800HEDQ14 kg kg 6795 7035 6825 7065 6845 7105 6855 7105 6907 7157 8607 8997 9110 9520 9290 9820 kg kg 7082 7322 7112 7352 7132 7392 7142 7392 7186 7436 8886 9276 9422 9602 9612 10150 10240 10784 10804 9832 10132 10142 10670 10750 11314 11344 OPC525HE+D10 OPC550HE+D10 OPC600HE+D10 OPC650HE+D10 OPC700HE+D12 OPC750HE+D12 OPC800HE+D14 OPC850HE+D14 kg kg 6125 6545 6635 7035 6665 7045 6675 7085 6887 7407 7867 8397 8390 8910 8870 9410 8880 9420 kg kg 6412 6832 6922 7322 6952 7332 6962 7372 7166 7686 8146 8676 8702 9222 9182 9722 9192 9730 10310 10364 10384 9732 10280 10830 10894 10924 OPC525HE+DQ12 OPC550HE+DQ12 OPC600HE+DQ12 OPC650HE+DQ12 OPC700HE+DQ14 OPC750HE+DQ16 OPC800HE+DQ16 OPC1100HED16 OPC700HED12 7697 8107 kg kg 7525 7895 7555 7975 7585 7995 7595 7995 7647 8037 8767 9760 9770 10270 10813 10903 10940 10970 9287 10290 10290 10790 11333 11433 11470 11480 kg kg 7812 8182 7842 8262 7872 8282 7882 8282 7926 8316 9046 10072 10082 10582 11120 11210 11264 11294 9566 10602 10602 11102 11640 11740 11794 11804 OPC950HEDQ16 OPC1100HEDQ18 OPC650HED10 6727 7147 OPC1000HEDQ18 OPC600HED10 6435 6705 OPC950HED14 OPC550HED8 5945 6185 OPC900HEDQ16 OPC525HED8 5915 6175 OPC850HEDQ14 OPC500HED8 5895 6135 OPC500HE+D8 Single Pump Option Weight - Machine Weight - Operating Run/Standby Pump Option Weight - Machine Weight - Operating kg kg OPC500HE+DQ12 Single Pump Option Weight - Machine Weight - Operating Run/Standby Pump Option Weight - Machine Weight - Operating OPC1000HED16 High Efficiency 9300 9843 9933 10460 10480 9830 10363 10443 10990 11020 Single Pump Option Weight - Machine Weight - Operating Run/Standby Pump Option Weight - Machine Weight - Operating (1) OPC1100HE+D18 OPC1000HE+D18 OPC950HE+D18 OPC900HE+D16 OPC1100HE+DQ20 OPC1000HE+DQ20 OPC950HE+DQ20 9423 10003 10040 10060 9973 10523 10570 10600 OPC900HE+DQ20 Single Pump Option Weight - Machine Weight - Operating Run/Standby Pump Option Weight - Machine Weight - Operating OPC850HE+DQ18 High Efficiency Plus Machine weight includes refrigerant charge; operating weight includes refrigerant charge and water volume. Chillers Installation & Maintenance : 6564868 09/2012 19 OPTICHILL Chillers Installation Data UNIT LIFTING IMPORTANT Employ lifting specialists Local codes and regulations relating to the lifting of this type of equipment should be observed Use the appropriate spreader bars/lifting slings (provided by others) with the holes/lugs provided Attach individual lifting chains to each of the lifting eye bolts/lifting lugs provided; each individual chain must be capable of lifting the whole unit Do not use 1 chain between 2 lifting points to avoid load shift. Only use lifting points provided. IMPORTANT Lifting hole/lug dimension: 40mm Chains/slings MUST NOT interfere with the casing or fan assembly to avoid damage Lift the unit slowly and evenly If the unit is dropped, it should immediately be checked for damage and reported to Airedale. LIFTING DIMENSIONS 8 - 10 Fan 2300 A1 C B 12 - 20 Fan A2 2300 A1 B C C 8 FAN 10 FAN 12 FAN 14 FAN 16 FAN 18 FAN 20 FAN IMPORTANT 20 mm mm mm mm mm mm mm A1 (Min) 4000 4000 4000 5000 5000 6000 7000 A2 (Min) N/A N/A 5000 5000 5000 5000 5000 B 520 846 520 520 520 520 520 For models with optional pumps fitted, a separate instruction will be provided. Chillers Installation & Maintenance : 6564868 09/2012 C 3200 3500 4000 4650 5000 5650 6650 Chillers OPTICHILL Installation Data ANTI VIBRATION MOUNTING (OPTIONAL) Spring Type Each mount is coloured to indicate the different loads, refer to AV selection sheet supplied separately for correct allocation. Dimensions mm (1) (2) A(1) 180 B 130 C 225 D 186 E 20 FØ 16 Unloaded dimension For models with optional pumps fitted, please consult Airedale. A F B D E E C Components 2 1 9 6a 5 3 4 8 7 6b 1 2 3 4 5 6a 6b 7 8 9 10 Locating Screw Retaining Nut & Washer Levelling Screw Levelling Lock Nut Retaining Studs Upper Retaining Nuts Lower Retaining Nuts Spring assembly Pressure Plate Top Plate Bolting-down holes 10 Installation 1 2 3 4 5 6 CAUTION Mountings must be adjusted incrementally in turn. Do not fully adjust 1 mount at a time as this may overload and damage springs. 7 8 CAUTION Locate and secure mount using bolting down holes (10) in base plate. Ensure mounts are located in line with the unit base. If applicable, remove compressor enclosure covers to allow access to mount fixing holes in the unit base. Lock the upper retaining nuts (6a) to the underside of the top plate (9) before a load is applied. Remove retaining nut and washer (2), lower the unit onto the mounts and replace retaining nut and washer. Beginning with the mount with the largest deflection, adjust the height of each mount using the levelling screw (3). When all mounts are level, lock each into place using the levelling lock nut (4). Lock all retaining nuts (6a and 6b) to the extreme ends of the retaining studs (5). Do not connect any services until all anti vibration mounts have been fully adjusted. Pad Type Components/Installation 2 2 1 5 3 3 64 7 1 2 3 4 5 6 7 M16 Bolt (Not Supplied) Washer (Not Supplied) Fixing Pad 506-063 A V Pad 506-062 2 x M16 Nut (Not Supplied) Unit Base Unit Mounting Plinth Chillers Installation & Maintenance : 6564868 09/2012 21 OPTICHILL Chillers Installation Data POSITIONING CAUTION The installation position should be selected with the following points in mind: Position on a stable and even base, levelled to ensure that the compressor operates correctly Levelling should be to +/- 5mm Where vibration transmission to the building structure is possible, fit spring antivibration mounts and flexible water connections Observe airflow and maintenance clearances Pipework and electrical connections are readily accessible Where multiple units are installed, due care should be taken to avoid the discharge air from each unit adversely affecting other units in the vicinity Within a side enclosed installation, the fan MUST be higher than the enclosing structure Increase airflow and maintenance clearances for side-enclosed or multiple unit applications Ensure there are no obstructions directly above the fans Allow free space above the fans to prevent air recirculation Prior to connecting services, ensure that the equipment is installed and completely level. AIRFLOW & MAINTENANCE CLEARANCES (1) (1) 1300mm / (2600mm) Application Single unit Side-enclosed or multiple units 22 Chillers Installation & Maintenance : 6564868 09/2012 Distance from Overall Base Dimension 1300mm 2600mm Chillers OPTICHILL Installation Data WATER SYSTEM CAUTION GROOVED & CLAMPED TYPE CONNECTION Chilled water pipework and ancillary components must be installed in accordance with: National and Local Water supply company standards The manufacturer's instructions are followed when fitting ancillary components The system liquid is treated to prevent corrosion and algae forming In ambients of 0°C and below, where static water can be expected, or when water supply temperatures of +5°C or below is required, the necessary concentration of Glycol or use of an electrical trace heater must be included The schematic is referred to as a guide to ancillary recommendations The unit water connections are NOT designed to support external pipework, pipework MUST be supported separately. 1 Place Grooved Ends Together 2 Locate Rubber Gasket Note that an expansion gap of 5mm is shown here The gasket should be checked for compatability and damage prior to installation A thin coat of sealing lubricant should be applied to both the inside and outside mating surfaces Slip the gasket fully onto one of the pipe ends, align the second pipe and slide the gasket into place 3 Place Clamp over Gasket Wrap the 2-halves of the clamp over the gasket Ensure the gasket fits snugly within the grooved recess within the inside of the clamp and that the clamp mates correctly 4 Secure Clamp Tightend the bolts incrementally and evenly at both sides until a leak free seal is formed The gasket should not be visible beneath the clamp when the bolts are properly tightened Chillers Installation & Maintenance : 6564868 09/2012 23 OPTICHILL Chillers Installation Data 3 REFRIGERATION SCHEMATIC 4 2 5 A 7 A2 1 6 A1 8 9 1 2 3 4 5 6 Screw compressor Muffler (DQ Only) Ball Valve - Discharge Ball Valve - Liquid Sight Glass Filter driver - Replaceable core 7 8 9 A A1 A2 Solenoid valve EEV Evaporator Economiser Circuit EEV Heat exchanger STANDARD RECOMMENDED INSTALLATION (Parts Supplied by Others) The following diagram illustrates the minimum component installation requirements. A wide range of optional extras are available to suit various applications, please refer to Optional extras, on page 10 for details. GENERAL CAUTION The following installation recommendations should be adhered to. Failure to do this will invalidate the chiller warranty. (2) (3) P T (5) T (6) (4) (1) P (1) (2) (3) (4) (5) (6) CAUTION Flexible connections Pressure gauges Temperature gauges Binder points De-aerator (optional extra) Auto air vent (at highest point) (9) (11) (7) (8) (7) (8) (9) (10) (11) (12) (12) (10) Strainer (optional extra) Flow switch Shut off valves Bypass circuit (for flushing) Pump Pump strainer Full design water flow MUST be maintained at all times. Variable water volume is NOT recommended and will invalidate warranty The correct operation of the flow proving device is critical if the chiller warranty is to be valid. Following components are fitted within the chiller unit as standard: Temperature Sensors Drain Point Auto Air Vent 24 Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL Installation Data WATER SYSTEM Component Recommended Requirements The recommended requirements to allow commissioning to be carried out correctly are: The inclusion of Binder Points adjacent to the flow and return connections, to allow temperature and pressure readings A flow switch or equivalent, fitted adjacent to the water outlet side of the unit Chiller A 20 mesh strainer fitted prior to the evaporator inlet A water-flow commissioning valve set fitted to the system In multiple chiller installations, 1 commissioning valve set is required per chiller Isolating valves should be installed adjacent to all major items of equipment for ease of maintenance Balancing valves can be installed if required to aid correct system balancing All chilled water pipework must be insulated and vapour sealed to avoid condensation If several units are installed in parallel adjacent to each other, reverse return should be applied to avoid unnecessary balancing valves Pump Statement When installing circulating water pumps or equipment containing them, the following rules should be applied: Interlocks & Protection CAUTION Ensure the system is filled with liquid then vented and the pump primed with water before running the pump, this is required because the pumped liquid cools the pump bearings and mechanical seal faces To avoid cavitation the NPSH (Net Positive Suction Head) incorporating a safety margin of 0.5m head must be available at the pump inlet during operation Always electrically interlock the operation of the chiller with the pump controls and flow proving device for safety reasons. Failure to install safety devices will invalidate the chiller warranty. Do not rely solely on the BMS to protect the chiller against low flow conditions. An evaporator pump interlock and flow proving device MUST be directly wired to the chiller, refer to Interconnecting wiring, on page 31. Pressure Testing When all the pipework has been connected in the system, proceed as follows: Ensure all shut off and control valves are fully open Pressurise system to the operating pressure, hold for 1 hour (a gradual fall in pressure shown on the gauge indicates a leak) Leaks should be found and repaired and the unit pressure tested for a further hour When the pressure remains at the operating pressure for 1 hour, the system can be considered leak free. CAUTION Although a pressure of 1.5 x working pressure is adequate for testing purposes, most local water authorities require 2 x working pressure. RECORD Record on commissioning sheet provided once completed. CAUTION The whole system MUST be flushed prior to filling to remove debris left in the water pipework by using a flushing bypass as shown to avoid serious damage to the plate evaporator. Filling During filling the system should be vented at all high points Once the system has been completely vented all vents should be closed To prevent air locking in the system it is advisable to fill the systems from the lowest point, ie drain point on pipework If auto air vents are used then we strongly recommend an auto pressurisation unit be fitted to the system Chillers Installation & Maintenance : 6564868 09/2012 25 OPTICHILL Chillers Installation Data GLYCOL DATA CAUTION For a given percentage of glycol in the system there are correction factors that need to be applied, the following tables can be used as a guide. The source data must be at 100% Water for the correction factors to be valid. Ethylene Glycol Nominal Correction Factors Glycol in System / Freezing Point ºC Output (kW) Compressor Input (kW) x Water Flow (l/s) Pressure Drop (kPa) 10% / -4°C 0.98 0.99 0.99 1.05 20% / -9°C 0.97 0.98 1.02 1.20 30% / -15°C 0.95 0.96 1.04 1.38 40% / -23°C 0.93 0.95 1.07 1.57 20% / -6°C 0.95 0.98 0.97 1.17 30% / -12°C 0.91 0.96 0.95 1.31 40% / -20°C 0.88 0.95 0.95 1.45 Propylene Glycol Nominal Correction Factors Glycol in System / Freezing Point ºC Output (kW) Compressor Input (kW) x Water Flow (l/s) Pressure Drop (kPa) 10% / -2°C 0.97 0.99 0.98 1.08 Model Ref. Ambient: Fluid Inlet Fluid Temp. Outlet Fluid Temp. Example Output (kW) Compressor Input (kW) Water Flow (l/s) Pressure Drop (kPa) = Input (kW) - TFP {283.1 - {14 x 1.7}} = Output 4.19 x ΔT Plot from curve (refer to Waterside pressure drop (kPa), on page 46) Where: Output Compressor Input TFP (Total Fan Power) Water Flow ΔT CAUTION = OPC800HE+D14 = 35°C = 20% Ethylene Glycol = 7°C = 12°C (5°C T) 100% Water 841.2 259.3 Multiplier Corrected Figure x 0.97 = 816.0 kW x 0.98 = 254.1 kW 40.2 x 1.02 = 40.8 l/s 33.1 x 1.20 = 39.7 kPa = (kW) Output (kW), refer to Technical Manual = (kW) Input (kW) refer to Technical Manual (-) Minus TFP = (kW) Quantity of Fans to unit x Fan Motor Size = (l/s) ALWAYS USE 100% water SHC of 4.19 = (°C) Difference of Entering Water and Leaving Water temperature Waste glycol needs to be handled responsibly, recycled or turned over to professional personnel for correct disposal. Most anti-freeze manufacturers recommend that used antifreeze be collected and disposed according to Local Legislation. Waste glycol should NOT be drained onto the ground, rainwater drainage system or natural waters. If the glycol contains heavy metals or other contaminants from gas or oil, the level of hazard posed by the glycol is increased and could be characterised as hazardous waste. STEPS IF GLYCOL IS RELEASED/SPILLED Small spill - soak up with absorbent material. Large spill - contain spill and pump to suitable container for disposal. 26 Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL Installation Data PUMPS OPTIONS CAUTION Full design water flow MUST be maintained at all times. Variable water volume is NOT recommended and will invalidate warranty. A variety of pump options to suit a wide range of applications is available: Factory fitted in line as a single pump or run/standby configuration and available in standard and larger nominal external head pressures. Factory fitted run/standby pumps have a shut off valve to the inlet and a non return valve to the outlet enabling one pump to be maintained without interrupting chiller flow. Supplied with electrical switchgear and isolating valve as standard. Run/standby pumps may be rotated manually to ensure even pump usage and prolong component life. For performance curves, please refer to Commissioning Data, on page 47. The pump motor speed can be supplied as fixed or variable: Standard - ac Motor Fixed Speed The standard ac electric motors are 400Vac / 50Hz / 3ph and fixed speed. Inverter Driven Motor Variable Speed for constant water flow Flow is monitored by the onboard electronic flow meter to maintain the exact requirement of the application, thus saving pump input power whilst providing optimum chilled water flow control. The option of an onboard variable speed drive combined with the electronic flow metering system offers an exceptional combination of simple commissioning and optimised efficiency. Flow Schemes: A B C D Single Head Pump - Standard ac Motor - Fixed Speed Run/Standby Pump - Standard ac Motor - Fixed Speed Single Head Pump - Inverter Driven Motor - Variable Speed with electronic flow metering system Run/Standby Pump - Inverter Driven Motor - Variable Speed with electronic flow metering system 5 1 1 1 5 4-20 mA 6 6 0-10V 4 2a 4 1 2a 2b 3 0-10V 2b 2b 2a A 4-20 mA 1 3 3 3 3 1 1 1 1 B Shut off valve Pump Pump & Inverter Liquid Strainer C D 4 5 6 Non Return Valve Electronic Flow Meter Microprocessor Chillers Installation & Maintenance : 6564868 09/2012 27 OPTICHILL Chillers Installation Data MECHANICAL DATA - HIGH EFFICIENCY OPC500HED8 Connections Water Inlet / Outlet Water Drain / Bleed Water System Min. System Water Volume Max. System Operating Pressure OPTIONAL EXTRAS Water Pump - ac Motor Single Head or Run/Standby Nom External Head Single - Standard Nom External Head Single - Larger Water Pump - Inverter Driven Motor Single Head or Run/Standby Nom External Head Single - Standard Nom External Head Single - Larger in DN150 PN16 1/2 l bar 1764 10 (1) 1849 10 1934 10 OPC650HED10 DN200 PN16 1/2 2079 10 2260 10 56 94 76 179 67 155 87 174 OPC525HEDQ10 OPC550HEDQ10 OPC600HEDQ10 Grooved type Coupling & Pipe Assembly DN150 PN16 DN150 PN16 DN150 PN16 1/2 1/2 1/2 OPC650HEDQ10 In Line Pump - Fixed Speed Motor kPa kPa 70 107 kPa kPa 124 124 OPC500HEDQ10 Connections Water Inlet / Outlet Water Drain / Bleed Water System Min. System Water Volume Max. System Operating Pressure OPTIONAL EXTRAS Water Pump - ac Motor Single Head or Run/Standby Nom External Head Single - Standard Nom External Head Single - Larger Water Pump - Inverter Driven Motor Single Head or Run/Standby Nom External Head Single - Standard Nom External Head Single - Larger OPC525HED8 OPC550HED8 OPC600HED10 Grooved type Coupling & Pipe Assembly DN150 PN16 DN150 PN16 DN150 PN16 1/2 1/2 1/2 in DN150 PN16 1/2 l bar 1750 10 (1) 66 63 104 100 In Line Pump - Variable Speed Motor 120 120 1832 10 117 117 1915 10 DN150 PN16 1/2 2001 10 2087 10 60 97 56 159 71 159 67 155 OPC525HE+D10 OPC550HE+D10 OPC600HE+D10 Grooved type Coupling & Pipe Assembly DN200 PN16 DN200 PN16 DN200 PN16 1/2 1/2 1/2 OPC650HE+D10 In Line Pump - Fixed Speed Motor kPa kPa 71 108 kPa kPa 124 124 67 64 105 101 In Line Pump - Variable Speed Motor 121 121 118 118 MECHANICAL DATA - HIGH EFFICIENCY PLUS OPC500HE+D8 Connections Water Inlet / Outlet Water Drain / Bleed Water System Min. System Water Volume Max. System Operating Pressure OPTIONAL EXTRAS Water Pump - ac Motor Single Head or Run/Standby Nom External Head Single - Standard Nom External Head Single - Larger Water Pump - Inverter Driven Motor Single Head or Run/Standby Nom External Head Single - Standard Nom External Head Single - Larger in DN200 PN16 1/2 l bar 1825 10 (1) (1) kPa kPa 87 124 kPa kPa 140 140 in DN200 PN16 1/2 l bar 1850 10 (1) 2164 10 2297 10 78 116 89 192 89 177 100 187 OPC525HE+DQ12 OPC550HE+DQ12 OPC600HE+DQ12 Grooved type Coupling & Pipe Assembly DN200 PN16 DN200 PN16 DN200 PN16 1/2 1/2 1/2 OPC650HE+DQ12 83 81 121 118 In Line Pump - Variable Speed Motor 137 137 1947 10 135 135 2044 10 DN200 PN16 1/2 2139 10 2234 10 79 116 76 179 90 177 87 175 In Line Pump - Fixed Speed Motor kPa kPa 86 123 kPa kPa 140 140 Based on 12/7°C water temperature and 35°C ambient. 28 2067 10 In Line Pump - Fixed Speed Motor OPC500HE+DQ12 Connections Water Inlet / Outlet Water Drain / Bleed Water System Min. System Water Volume Max. System Operating Pressure OPTIONAL EXTRAS Water Pump - ac Motor Single Head or Run/Standby Nom External Head Single - Standard Nom External Head Single - Larger Water Pump - Inverter Driven Motor Single Head or Run/Standby Nom External Head Single - Standard Nom External Head Single - Larger 1967 10 DN200 PN16 1/2 Chillers Installation & Maintenance : 6564868 09/2012 84 81 121 119 In Line Pump - Variable Speed Motor 137 137 135 135 Chillers OPTICHILL OPC700HED12 OPC750HED12 DN200 PN16 1/2 DN200 PN16 1/2 2475 10 2637 10 OPC800HED12 OPC850HED12 OPC900HED14 Grooved type Coupling & Pipe Assembly DN200 PN16 DN200 PN16 DN200 PN16 1/2 1/2 1/2 2779 10 2977 10 3171 10 OPC950HED14 OPC1000HED16 OPC1100HED16 DN200 PN16 1/2 DN200 PN16 1/2 DN200 PN16 1/2 3302 10 3518 10 3669 10 81 172 76 167 98 164 108 167 103 226 99 222 OPC950HEDQ16 OPC1000HEDQ18 OPC1100HEDQ18 DN200 PN16 1/2 DN200 PN16 1/2 DN200 PN16 1/2 3231 10 3434 10 3581 10 83 174 78 169 100 166 109 169 105 228 101 224 OPC950HE+D18 OPC1000HE+D18 OPC1100HE+D18 DN200 PN16 1/2 DN200 PN16 1/2 DN200 PN16 1/2 3412 10 3567 10 3722 10 78 170 75 166 97 163 105 165 102 224 98 221 In Line Pump - Fixed Speed Motor 81 173 77 168 72 164 81 168 76 163 71 159 OPC700HEDQ14 OPC750HEDQ14 DN200 PN16 1/2 DN200 PN16 1/2 2437 10 2594 10 88 84 179 175 In Line Pump - Variable Speed Motor 87 174 111 170 OPC800HEDQ14 OPC850HEDQ14 OPC900HEDQ16 Grooved type Coupling & Pipe Assembly DN200 PN16 DN200 PN16 DN200 PN16 1/2 1/2 1/2 2785 10 2928 10 3109 10 In Line Pump - Fixed Speed Motor 82 174 78 169 92 183 82 169 77 164 91 178 OPC700HE+D12 OPC750HE+D12 DN200 PN16 1/2 DN200 PN16 1/2 2519 10 2698 10 89 85 180 177 In Line Pump - Variable Speed Motor 88 175 112 172 OPC800HE+D14 OPC850HE+D14 OPC900HE+D16 Grooved type Coupling & Pipe Assembly DN200 PN16 DN200 PN16 DN200 PN16 1/2 1/2 1/2 2891 10 3040 10 3226 10 In Line Pump - Fixed Speed Motor 97 188 100 191 90 181 96 184 99 187 89 176 OPC700HE+DQ14 OPC750HE+DQ16 DN200 PN16 1/2 DN200 PN16 1/2 2480 10 2693 10 87 83 178 174 In Line Pump - Variable Speed Motor 86 173 109 169 OPC800HE+DQ16 OPC850HE+DQ18 OPC900HE+DQ20 OPC950HE+DQ20 OPC1000HE+DQ20 OPC1100HE+DQ20 Grooved type Coupling & Pipe Assembly DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 DN200 PN16 1/2 1/2 1/2 1/2 1/2 1/2 2840 10 3030 10 3201 10 3337 10 3486 10 3636 10 80 172 77 168 99 165 107 167 104 226 100 223 In Line Pump - Fixed Speed Motor 97 189 93 185 91 182 97 184 93 180 90 177 87 83 178 175 In Line Pump - Variable Speed Motor 86 173 110 170 Chillers Installation & Maintenance : 6564868 09/2012 29 OPTICHILL Chillers Installation Data ELECTRICAL General As standard the equipment is designed for 400V, 3 phase, 3 wire 50Hz and a separate permanent 230V, 1 phase, 50Hz supply, to all relevant IEE regulations, British standards and IEC requirements The control voltage to the interlocks is 24V, always size the low voltage interlock and protection cabling for a maximum voltage drop of 2V Avoid large voltage drops on cable runs, particularly low voltage wiring Once the connecting pipework is complete the electrical supply can be connected by routing the cable through the appropriate casing hole and connecting the cables, refer to the Wiring Diagram supplied with each unit The equipment contains live electrical and moving parts, ISOLATE prior to maintenance or repair work. The unit isolators DO NOT isolate the incoming mains supply, but isolate the individual electrical panels. Isolate REMOTELY the mains incoming supply to the BUSBAR chamber prior to maintenance or repair work. CAUTION ALL work MUST be carried out by technically trained competent personnel. The Emergency Stop MUST NOT be used to stop the chiller other than in the event of an emergency. A fused and isolated electrical supply of the appropriate phase, frequency and voltage should be installed. Wires should be capable of carrying the maximum load current under non-fault conditions at the stipulated voltage. A separately fused, locally isolated, permanent single phase and neutral supply MUST BE FITTED for the compressor oil heater, evaporator trace heating and control circuits, FAILURE to do so will INVALIDATE WARRANTY. To reduce down time, if possible support the above supply with a UPS. Ensure correct phase rotation. Refer also to Interlocks & Protection, on page 25. 30 Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL Installation Data INTERCONNECTING WIRING Mains incoming supply 400V/3PH/50Hz (N2 only required for Power Meter Option) Separate Permanent Supply 230V / 1PH +N / 50Hz External Trace Heating Connections 230V/500W max 502 507 (1) Remote Pump Interlock 24VAC 502 505 (1) Evaporator Pump Water Flow Switch 24VAC 502 504 Unit Remote On/Off 24VAC 502 506 Setback Setpoint Temperature switch 581 580 582 NonCritical Alarm Volt Free Common Alarm Volt Free Alarm N/O Volt Free Alarm N/C 591 590 592 Critical Alarm Volt Free Common Alarm Volt Free Alarm N/O Volt Free Alarm N/C RX-/TxRX+/Tx+ GND L1 L2 L3 N2 E L4 N1 E 11 N OPC500 - OPC1100 CAUTION Network Connections (1) MUST be directly wired to the chiller to validate warranty. Chillers Installation & Maintenance : 6564868 09/2012 31 OPTICHILL Chillers Installation Data IMPORTANT The following information is for general guidance; refer to the certified drawings provided for installation. ELECTRICAL DATA - HIGH EFFICIENCY Standard Chiller - D Unit Data Nominal Run Amps Maximum Start Amps Rec Mains Fuse Size Mains Supply Max Mains Incoming Cable Size Permanent Supply Rec Permanent Fuse Size Max Permanent Incoming Cable Size Control Circuit Evaporator Immersion Heater Rating External Trace Heating Available (fitted by others) Condenser Fan - Per Fan Quantity Standard AC Type Full Load Amps Locked Rotor Amps Motor Size Optional EC Type Full Load Amps Motor Size Compressor - Per Compressor Quantity Motor Size Nominal Run Amps Oil Heater Rating Start Amps Type Of Start OPTIONAL EXTRAS Power Factor Correction Nominal Run Amps Maximum Start Amps Recommended Mains Fuse Compressor Nom Run Amps - Per Compressor Closed Transition Nominal Run Amps Maximum Start Amps Recommended Mains Fuse Compressor Nom Run Amps - Per Compressor Water Pump - ac Motor Single Head or Run/Standby - Standard Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps Single Head or Run/Standby - Larger Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps Water Pump - Inverter Driven Motor Single Head or Run/Standby - Standard Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps Single Head or Run/Standby - Larger Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps (1) (2) 32 (1) (2) (1) (2) OPC500HED8 OPC525HED8 OPC550HED8 OPC600HED10 OPC650HED10 A A A VAC mm² VAC A mm² VAC 291 461 400 308 521 450 325 538 450 400 V 3 PH 50 Hz Direct to Bus Bar 230 V 1 PH 50 Hz 16 16 4mm² Terminal 24V / 230VAC 347 589 450 361 604 500 16 16 W 100 100 100 100 100 W 500 500 500 500 500 8 8 8 10 10 A A kW 3.8 11 1.8 3.8 11 1.8 3.8 11 1.8 3.8 11 1.8 3.8 11 1.8 A kW 3.9 2.2 3.9 2.56 3.9 2.2 3.9 2.56 3.9 2.56 kW A W A 1+1 74.5 / 74.5 130.4 / 130.4 300 300 / 300 1+1 83.4 / 74.5 147.3 / 130.4 300 360 / 300 1+1 83.4 / 83.4 147.3 / 147.3 300 360 / 360 Star - Delta 1+1 91.8 / 83.4 161.5 / 147.3 300 404 / 360 1+1 91.8 / 91.8 161.5 / 161.5 300 404 / 404 16 (1) (2) A A A A 257 444 400 117 / 117 270 504 450 132 / 117 284 517 450 132 / 132 304 569 450 145 / 132 317 381 500 145 / 145 (1) (2) A A A A 291 461 400 130.4 / 130.4 308 521 450 147.3 / 130.4 325 538 450 147.3 / 147.3 347 589 450 161.5 / 147.3 361 604 500 161.5 / 161.5 (1) A A kW A 300 400 4.0 8.9 317 450 4.0 8.9 334 450 4.0 8.9 356 450 4.0 8.9 370 500 4.0 10.6 (1) A A kW A 306 400 7.5 14.4 322 450 7.5 14.4 339 450 7.5 14.4 361 500 7.5 14.4 382 500 11.0 21.0 (1) A A kW A 302 400 5.5 11.0 319 450 5.5 11.0 336 450 5.5 11.0 358 450 5.5 11.3 372 500 5.5 11.3 (1) A A kW A 302 400 5.5 11.0 319 450 5.5 11.0 336 450 5.5 11.0 362 450 7.5 15.0 376 500 7.5 15.0 Based at 12/7°C water and 35°C ambient with standard AC type fans. Starting amps refers to the Star connection only with standard AC type fans. Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL OPC700HED12 OPC750HED12 OPC800HED12 394 643 560 419 668 560 444 697 630 16 16 16 100 100 100 500 500 12 OPC850HED12 OPC900HED14 470 723 630 400 V 3 PH 50 Hz Direct to Bus Bar 230 V 1 PH 50 Hz 16 4mm² Terminal 24V / 230VAC OPC950HED14 OPC1000HED16 OPC1100HED16 512 851 710 546 886 710 576 957 750 597 979 750 16 16 16 16 100 100 100 100 100 500 500 500 500 500 500 12 12 12 14 14 16 16 3.8 11 1.8 3.8 11 1.8 3.8 11 1.8 3.8 11 1.8 3.8 11 1.8 3.8 11 1.8 3.8 11 1.8 3.8 11 1.8 3.9 2.56 3.9 2.56 3.9 2.56 3.9 2.56 3.9 2.56 3.9 2.56 3.9 2.56 3.9 2.56 1+1 109.2 / 91.8 186.6 / 161.5 300 436 / 404 1+1 109.2 / 109.2 186.6 / 186.6 300 436 / 436 1+1 126.5 / 109.2 212.2 / 186.6 300 465 / 436 1+1 1+1 162.5 / 162.5 143.1 / 126.5 212.2 / 212.2 246.5 / 212.2 300 300 465 / 465 586 / 465 Star - Delta 1+1 143.1 / 143.1 246.5 / 246.5 300 586 / 586 1+1 156.4 / 143.1 268.3 / 246.5 300 650 / 586 1+1 156.4 / 156.4 268.3 / 268.3 300 650 / 650 351 621 560 167 / 145 377 648 560 167 / 167 404 677 630 190 / 167 430 703 630 190 / 190 463 831 710 221 / 190 488 857 710 246.5 / 246.5 516 928 750 268.3 / 246.5 536 948 750 240 / 240 394 643 560 186.6 / 161.5 419 668 560 186.6 / 186.6 444 697 630 212.2 / 186.6 470 723 630 212.2 / 212.2 512 851 710 246.5 / 212.2 546 886 710 246.5 / 246.5 576 957 750 268.3 / 246.5 597 979 750 268.3 / 268.3 404 560 5.5 10.6 429 560 5.5 10.6 455 630 5.5 10.6 481 630 5.5 10.6 522 710 5.5 10.6 557 710 5.5 10.6 586 750 5.5 10.6 612 750 7.5 14.4 415 560 11.0 21.0 440 560 11.0 21.0 465 630 11.0 21.0 491 630 11.0 21.0 533 710 11.0 21.0 567 710 11.0 21.0 597 750 11.0 21.0 618 750 11.0 21.0 405 560 5.5 11.3 430 560 5.5 11.3 456 630 5.5 11.3 481 630 5.5 11.3 527 710 7.5 14.7 561 710 7.5 14.7 590 750 7.5 14.7 612 750 7.5 14.7 409 560 7.5 15.0 440 560 11.0 21.4 466 630 11.0 21.4 491 630 11.0 21.4 533 710 11.0 21.4 568 710 11.0 21.4 604 750 15.0 28.0 625 750 15.0 28.0 Chillers Installation & Maintenance : 6564868 09/2012 33 OPTICHILL Chillers Installation Data IMPORTANT The following information is for general guidance; refer to the certified drawings provided for installation. ELECTRICAL DATA - HIGH EFFICIENCY Quiet Chiller - DQ Unit Data Nominal Run Amps Maximum Start Amps Rec Mains Fuse Size Mains Supply Max Mains Incoming Cable Size Permanent Supply Rec Permanent Fuse Size Max Permanent Incoming Cable Size Control Circuit Evaporator Immersion Heater Rating External Trace Heating Available (fitted by others) Condenser Fan - Per Fan Quantity Full Load Amps Motor Size Compressor - Per Compressor Quantity Motor Size Nominal Run Amps Oil Heater Rating Start Amps Type Of Start OPTIONAL EXTRAS Power Factor Correction Nominal Run Amps Maximum Start Amps Recommended Mains Fuse Compressor Nom Run Amps - Per Compressor Closed Transition Nominal Run Amps Maximum Start Amps Recommended Mains Fuse Compressor Nom Run Amps - Per Compressor Water Pump - ac Motor Single Head or Run/Standby - Standard Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps Single Head or Run/Standby - Larger Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps Water Pump - Inverter Driven Motor Single Head or Run/Standby - Standard Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps Single Head or Run/Standby - Larger Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps (1) (2) 34 (1) (2) (1) (2) OPC500HEDQ10 OPC525HEDQ10 OPC550HEDQ10 OPC600HEDQ10 OPC650HEDQ10 A A A VAC mm² VAC A mm² VAC 277 446 400 294 506 450 311 523 450 400 V 3 PH 50 Hz Direct to Bus Bar 230 V 1 PH 50 Hz 16 16 4mm² Terminal 24V / 230VAC 325 567 450 339 582 500 16 16 W 100 100 100 100 100 W 500 500 500 500 500 A kW 10 3.9 2.2 10 3.9 2.56 10 3.9 2.56 10 3.9 2.56 10 3.9 2.56 kW A W A 1+1 74.5 / 74.5 130.4 / 130.4 300 300 / 300 1+1 83.4 / 74.5 147.3 / 130.4 300 360 / 300 1+1 83.4 / 83.4 147.3 / 147.3 300 360 / 360 Star - Delta 1+1 91.8 / 83.4 161.5 / 147.3 300 404 / 360 1+1 91.8 / 91.8 161.5 / 161.5 300 404 / 404 16 (1) (2) A A A A 242 429 400 113 / 113 256 489 450 127 / 113 269 503 450 127 / 127 282 547 450 139 / 122 295 559 500 139 / 139 (1) (2) A A A A 277 446 400 130.4 / 130.4 294 506 450 147.3 / 130.4 311 523 450 147.3 / 147.3 325 567 450 161.5 / 147.3 339 582 500 161.5 / 161.5 (1) A A kW A 286 400 4.0 8.9 303 450 4.0 8.9 319 450 4.0 8.9 334 450 4.0 8.9 348 500 4.0 10.6 (1) A A kW A 291 400 7.5 14.4 308 450 7.5 14.4 325 450 7.5 14.4 339 500 7.5 14.4 360 500 11.0 21.0 (1) A A kW A 288 400 5.5 11.0 305 450 5.5 11.0 322 450 5.5 11.0 336 450 5.5 11.3 350 500 5.5 11.3 (1) A A kW A 288 400 5.5 11.0 305 450 5.5 11.0 322 450 5.5 11.0 340 450 7.5 15.0 354 500 7.5 15.0 Based on 12/7°C water temperature and 35°C ambient. Starting amps refers to the Star connection only. Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL OPC700HEDQ14 OPC750HEDQ14 OPC800HEDQ14 370 620 560 396 645 560 421 674 630 16 16 16 100 100 100 500 500 14 3.9 2.56 OPC850HEDQ14 OPC900HEDQ16 447 700 630 400 V 3 PH 50 Hz Direct to Bus Bar 230 V 1 PH 50 Hz 16 4mm² Terminal 24V / 230VAC OPC950HEDQ16 OPC1000HEDQ18 OPC1100HEDQ18 484 824 710 519 858 710 544 925 710 565 947 750 16 16 16 16 100 100 100 100 100 500 500 500 500 500 500 14 3.9 2.56 14 3.9 2.56 14 3.9 2.56 16 3.9 2.56 16 3.9 2.56 18 3.9 2.56 18 3.9 2.56 1+1 109.2 / 91.8 186.6 / 161.5 300 436 / 404 1+1 109.2 / 109.2 186.6 / 186.6 300 436 / 436 1+1 126.5 / 109.2 212.2 / 186.6 300 465 / 436 1+1 1+1 162.5 / 162.5 143.1 / 126.5 212.2 / 212.2 246.5 / 212.2 300 300 465 / 465 586 / 465 Star - Delta 1+1 143.1 / 143.1 246.5 / 246.5 300 586 / 586 1+1 156.4 / 143.1 268.3 / 246.5 300 650 / 586 1+1 156.4 / 156.4 268.3 / 268.3 300 650 / 650 328 598 560 166 / 139 354 624 560 166 / 166 381 653 630 192 / 166 407 680 630 192 / 192 435 804 710 217 / 192 460 829 710 217 / 217 484 896 750 238 / 217 504 916 750 238 / 238 370 620 560 186.6 / 161.5 396 645 560 186.6 / 186.6 421 674 630 212.2 / 186.6 447 700 630 212.2 / 212.2 484 824 710 246.5 / 212.2 519 858 710 246.5 / 246.5 544 925 710 268.3 / 246.5 565 947 750 268.3 / 268.3 381 560 5.5 10.6 406 560 5.5 10.6 432 630 5.5 10.6 457 630 5.5 10.6 495 710 5.5 10.6 529 710 5.5 10.6 554 750 5.5 10.6 580 750 7.5 14.4 391 560 11.0 21.0 417 560 11.0 21.0 442 630 11.0 21.0 468 630 11.0 21.0 505 710 11.0 21.0 540 710 11.0 21.0 565 750 11.0 21.0 586 750 11.0 21.0 382 560 5.5 11.3 407 560 5.5 11.3 432 630 5.5 11.3 458 630 5.5 11.3 499 710 7.5 14.7 533 710 7.5 14.7 558 750 7.5 14.7 580 750 7.5 14.7 385 560 7.5 15.0 417 560 11.0 21.4 443 630 11.0 21.4 468 630 11.0 21.4 506 710 11.0 21.4 540 710 11.0 21.4 572 750 15.0 28.0 593 750 15.0 28.0 Chillers Installation & Maintenance : 6564868 09/2012 35 OPTICHILL Chillers Installation Data IMPORTANT The following information is for general guidance; refer to the certified drawings provided for installation. ELECTRICAL DATA - HIGH EFFICIENCY PLUS Standard Chiller - D & Quiet Chiller - DQ Unit Data Nominal Run Amps Maximum Start Amps Rec Mains Fuse Size Mains Supply Max Mains Incoming Cable Size Permanent Supply Rec Permanent Fuse Size Max Permanent Incoming Cable Size Control Circuit Evaporator Immersion Heater Rating External Trace Heating Available (fitted by others) Condenser Fan - Per Fan Quantity Full Load Amps Motor Size Compressor - Per Compressor Quantity Motor Size Nominal Run Amps Oil Heater Rating Start Amps Type Of Start QUIET DQ Condenser Fan - Per Fan Quantity Full Load Amps Motor Size OPTIONAL EXTRAS - ALL MODELS Power Factor Correction Nominal Run Amps Maximum Start Amps Recommended Mains Fuse Compressor Nom Run Amps - Per Compressor Closed Transition Nominal Run Amps Maximum Start Amps Recommended Mains Fuse Compressor Nom Run Amps - Per Compressor Water Pump - ac Motor Single Head or Run/Standby - Standard Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps Single Head or Run/Standby - Larger Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps Water Pump - Inverter Driven Motor Single Head or Run/Standby - Standard Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps Single Head or Run/Standby - Larger Unit Nominal Run Amps Recommended Mains Fuse Motor Size Full Load Amps (1) (2) 36 (1) (2) (1) (2) OPC500HE+D8 OPC525HE+D10 OPC550HE+D10 OPC600HE+D10 OPC650HE+D10 A A A VAC mm² VAC A mm² VAC 288 458 400 312 524 450 329 541 450 400 V 3 PH 50 Hz Direct to Bus Bar 230 V 1 PH 50 Hz 16 16 4mm² Terminal 24V / 230VAC 343 585 450 357 600 500 16 16 W 100 100 100 100 100 W 500 500 500 500 500 A kW 8 3.9 2.56 10 3.9 2.56 10 3.9 2.56 10 3.9 2.56 10 3.9 2.56 kW A W A 1+1 74.5 / 74.5 130.4 / 130.4 300 300 / 300 1+1 83.4 / 74.5 147.3 / 130.4 300 360 / 300 12 3.9 2.56 12 3.9 2.56 12 3.9 2.56 12 3.9 2.56 12 3.9 2.56 16 1+1 1+1 1+1 83.4 / 83.4 91.8 / 83.4 91.8 / 91.8 147.3 / 147.3 161.5 / 147.3 161.5 / 161.5 300 300 300 360 / 360 404 / 360 404 / 404 Star - Delta OPC500HE+DQ12 OPC525HE+DQ12 OPC550HE+DQ12 OPC600HE+DQ12 OPC650HE+DQ12 All data as above except: A kW (1) (2) A A A A 254 440 400 113 / 113 274 507 450 127 / 113 287 521 450 127 / 127 300 565 450 139 / 127 313 577 500 139 / 139 (1) (2) A A A A 288 458 400 130.4 / 130.4 312 524 450 147.3 / 130.4 329 541 450 147.3 / 147.3 343 585 450 161.5 / 147.3 357 600 500 161.5 / 161.5 (1) A A kW A 297 400 4.0 8.9 321 450 4.0 8.9 337 450 4.0 8.9 352 450 4.0 8.9 366 500 4.0 10.6 (1) A A kW A 302 400 7.5 14.4 326 450 7.5 14.4 343 450 7.5 14.4 357 500 7.5 14.4 378 500 11.0 21.0 (1) A A kW A 299 400 5.5 11.0 323 450 5.5 11.0 340 450 5.5 11.0 354 450 5.5 11.3 368 500 5.5 11.3 (1) A A kW A 299 400 5.5 11.0 323 450 5.5 11.0 340 450 5.5 11.0 358 450 7.5 15.0 372 500 7.5 15.0 Based on 12/7°C water temperature and 35°C ambient. Starting amps refers to the Star connection only. Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL OPC700HE+D12 OPC750HE+D12 OPC800HE+D14 389 638 560 414 663 560 446 699 630 16 16 16 100 100 100 500 500 12 3.9 2.56 1+1 109.2 / 91.8 186.6 / 161.5 300 436 / 404 OPC850HE+D14 OPC900HE+D16 OPC950HE+D18 OPC1000HE+D18 OPC1100HE+D18 513 853 710 554 894 710 576 958 750 598 980 750 16 16 16 16 100 100 100 100 100 500 500 500 500 500 500 12 3.9 2.56 14 3.9 2.56 14 3.9 2.56 16 3.9 2.56 18 3.9 2.56 18 3.9 2.56 18 3.9 2.56 1+1 109.2 / 109.2 186.6 / 186.6 300 436 / 436 1+1 126.5 / 109.2 212.2 / 186.6 300 465 / 436 1+1 143.1 / 143.1 246.5 / 246.5 300 586 / 586 1+1 156.4 / 143.1 268.3 / 246.5 300 650 / 586 1+1 156.4 / 156.4 268.3 / 268.3 300 650 / 650 OPC700HE+DQ14 OPC750HE+DQ16 All data as above except: OPC800HE+DQ16 1+1 1+1 162.5 / 162.5 143.1 / 126.5 212.2 / 212.2 246.5 / 212.2 300 300 465 / 465 586 / 465 Star - Delta OPC850HE+DQ18 OPC900HE+DQ20 472 725 630 400 V 3 PH 50 Hz Direct to Bus Bar 230 V 1 PH 50 Hz 16 4mm² Terminal 24V / 230VAC OPC950HE+DQ20 OPC1000HE+DQ20 OPC1100HE+DQ20 14 3.9 2.56 16 3.9 2.56 16 3.9 2.56 18 3.9 2.56 20 3.9 2.56 20 3.9 2.56 20 3.9 2.56 20 3.9 2.56 346 616 560 166 / 139 373 643 560 166 / 166 406 679 630 192 / 166 432 705 630 192 / 192 464 833 710 217 / 192 496 865 710 217 / 217 516 929 750 238 / 217 536 949 750 238 / 238 389 638 560 186.6 / 161.5 414 663 560 186.6 / 186.6 446 699 630 212.2 / 186.6 472 725 630 212.2 / 212.2 513 853 710 246.5 / 212.2 554 894 710 246.5 / 246.5 576 958 750 268.3 / 246.5 598 980 750 268.3 / 268.3 399 560 5.5 10.6 425 560 5.5 10.6 457 630 5.5 10.6 483 630 5.5 10.6 524 710 5.5 10.6 565 710 5.5 10.6 587 750 5.5 10.6 612 750 7.5 14.4 410 560 11.0 21.0 435 560 11.0 21.0 467 630 11.0 21.0 493 630 11.0 21.0 534 710 11.0 21.0 575 710 11.0 21.0 597 750 11.0 21.0 619 750 11.0 21.0 400 560 5.5 11.3 425 560 5.5 11.3 458 630 5.5 11.3 483 630 5.5 11.3 528 710 7.5 14.7 569 710 7.5 14.7 591 750 7.5 14.7 613 750 7.5 14.7 404 560 7.5 15.0 435 560 11.0 21.4 468 630 11.0 21.4 493 630 11.0 21.4 534 710 11.0 21.4 576 710 11.0 21.4 604 750 15.0 28.0 626 750 15.0 28.0 Chillers Installation & Maintenance : 6564868 09/2012 37 OPTICHILL Chillers Controls TEMPERATURE CONTROL Airedale recognises that all chiller applications are different but fall mainly into 2 application categories; Variable Supply Temperature and Constant Supply Temperature. The onboard microprocessor has the capability of satisfying either control requirement as illustrated below. Using the Airedale Variable Supply Temperature control scheme, energy savings are available when compared with previous schemes and that of the Constant Supply Temperature application. Variable Supply Temperature control schemes offer energy savings where the supply water temperature is not critical to its operation. Selection of the best application control scheme can be made via a soft switch in the microprocessor during initial commissioning. The microprocessor maintains the set supply Chilled Water temperature by sensing the return and supply water temperatures and ambient air temperature to adjust the compressor loading and water valve position as required. Variable Supply Temperature Control 14 Water Temperature °C 13 12 1 11 10 2 9 3 8 7 4 6 1 (20%) 2 (40%) 3 (50%) 4 (60%) 5 (70%) 6 (80%) 7 (90%) 8 (100%) 7 (90%) 8 (100%) Cooling Stages / Unit Capacity % 14 Constant Supply Temperature Control Water Temperature °C 13 12 1 11 10 9 3 8 7 6 1 (20%) 2 (40%) 3 (50%) 4 (60%) 5 (70%) 6 (80%) Cooling Stages / Unit Capacity % 1 2 3 4 CAUTION Return Water Temperature Mean Value Supply Water Temperature Compressor Off Factory set to Variable Supply Temperature Control unless otherwise stated at order. Only when the mode selection has been set can the unit be enabled. 38 Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL Controls GENERAL DESCRIPTION The microprocessor controller offers powerful analogue and digital control to meet a wide range of monitoring and control features including a real time clock and Industry standard communication port and network connections. The controller’s inbuilt display is used for viewing the unit operating status and making adjustments to control parameters by allowing the operator access to a series of display pages. Also featured are a visual alarm and the facility to adjust and display control settings by local operator for information and control. 6 DISPLAY/KEYPAD 5 4 3 7 1 2 1 UP/DOWN KEYS - To change Adjustable Fields & Scrolls up & down available Menus 2 ENTER -Selects Menus & Moves Cursor to Adjustable Fields Green LED 3 ESC - Green LED lit when Operating Page displayed, Returns to Operating Page Screen when pressed 4 PROGRAM - Opens the Available Menus 5 ALARM - Red LED Indicates Alarm Present 6 4 ROW LCD DISPLAY 7 CURSOR (FLASHING) Top Left Position = “HOME” Indicates adjustable Fields OPERATION Navigation The display is used for Viewing Unit Operating Status and Adjusting Customer Control Settings by allowing the operator access to a series of Menus & sub-menus. Viewing information is unrestricted, however set up and adjustment requires password entry, refer to Password Protection, on page 40. Prg Initially, use the key to access Menus, the symbol will appear top right and the first menu will appear in CAPITALS, these indicators shows which menu is selected. Use the open the menu. keys to move the indicator Use the key to move the flashing cursor keys to change the values. Press the the to to adjustable fields and the key to move the cursor to the next field or Home. When the cursor is Home either use the Esc to the desired menu and press keys to scroll to next sub-menu or to exit and return to the Standard Operating page. Chillers Installation & Maintenance : 6564868 09/2012 39 OPTICHILL Chillers Controls OPERATION Standard Operating Page The following Menus can be accessed from the Operating Page, it is recommended that Password Protection To guard against unauthorised adjustments, a password is required to gain access to certain menus as defined below. the display is always returned to the Operating Page by using the Esc key FACTORY SET PASSWORD PIN NUMBER: 4648 (or Customer chosen number). When a password is requested use the access the page. Menus (Listed in Sequence) keys to enter the number and Menu Description Password Unit On/Off Enable or Disable the unit Displays hours run for compressors and pumps (if fitted). Also includes Electronic Expansion Valves (if fitted). Display last 100 alarms in chronological order. Displays current status on digital and analogue inputs and outputs. Allows adjustment of real time clock, time zones Allows setpoint adjustment, includes supply temperature setpoint and unit temperature differential. Allows selection of setpoint limits, enables unit on/off from display, remote on/off and remote pump on/off. Factory use only. Open Access Maintenance Alarm Log Input/Output Clock Setpoint User Manufacturer to Default 4648 Open Access Open Access Default 4648 Default 4648 Default 4648 Airedale Only SETTING UP Unit On/Off Esc By pressing the and simultaneously for approximately 5 seconds, the unit operation will stop or start. The unit can also be enabled through the Unit On/Off menu. Real Time Clock The units leave the factory set, however follow the Navigation instructions if necessary. Time Zones The programme provides 3 On/Off periods per day, 7 days per week. The unit is factory set for continuous operation. Technical Support For further details, please contact Airedale. 40 Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL Controls VIEWING UNIT OPERATING STATUS Status Menu Allows access to view operating status of Digital and Analogue Inputs and Outputs. Using the Navigation instructions, the following Sub-Menus shown in sequence can be accessed: Digital Inputs ID1 ID2 ID3 ID4 ID5 ID6 ID7 ID8 ID9 ID10 ID11 ID12 ID13 ID14 ID15 ID16 ID17 ID18 Phase Rotation (Optional) Emergency Stop Evaporator Flow Switch Remote On/Off (Optional) Compressor 1 Contactor Status Circuit 1 Low Pressure Switch Compressor 1 Overload Circuit 1 Isolator Status Circuit 1 Discharge Gas Thermostat Compressor 2 Contactor Status Circuit 2 Low Pressure Switch Compressor 2 Overload Circuit 2 Isolator Status Circuit 2 Discharge Gas Thermostat Pump 1 Contactor Status (Optional) Pump 2 Contactor Status (Optional) Remote Pump Enable Summer / Winter Setpoint Enable Analogue Inputs B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 Circuit 1 Discharge Temperature Circuit 1 Liquid Pressure Refrigerant Leak Detector (Optional) Return Water Temperature (Optional) Supply Water Temperature Circuit 2 Liquid Pressure Evaporator Differential Pressure (Optional) Circuit 2 Discharge Temperature Not Used Ambient Temperature (Optional) Digital Outputs NO1 NO2 NO3 NO4 NO5 NO6 NO7 NO8 NO9 NO10 NO11 NO12 NO13 NO14 NO15 NO16 NO17 NO18 Compressor 1 Line Contactor Compressor 1 Star Contactor Compressor 1 Delta Contactor Compressor 1 Economiser Solenoid Valve Compressor 1 CR1 Solenoid Valve Compressor 1 CR2 Solenoid Valve Compressor 1 CR3 Solenoid Valve Non-Critical Alarm Compressor 2 Line Contactor Compressor 2 Star Contactor Compressor 2 Delta Contactor Compressor 1 CR4 Solenoid Valve Critical Alarm Compressor 2 CR3 Solenoid Valve Compressor 2 CR4 Solenoid Valve Compressor 2 Economiser Solenoid Valve Compressor 2 CR1 Solenoid Valve Compressor 2 CR2 Solenoid Valve Analogue Outputs Y1 Y2 Y3 Y4 Y5 Y6 Not Used Circuit 1 Condenser Fan Speed Controller Circuit 2 Condenser Fan Speed Controller Pump 1 Contactor (Optional) Pump 2 Contactor (Optional) Not Used Chillers Installation & Maintenance : 6564868 09/2012 41 OPTICHILL Chillers Controls ALARMS The controller logs and allows viewing of the last 100 conditions recorded in descending chronological order. 1 2 3 Alarm Handling 1 A Red LED behind the Alarm alarms, simply press the 2 1 2 5 3 4 5 Alarm Label Alarm Status: Alarm Active or Alarm Cleared Time of Alarm Alarm Log Date of Alarm key will light in the event of an alarm. To view the key and the keys to scroll through. Auto reset alarms will clear following this first depression of the Alarm however the Red LED behind the Alarm requires some form of manual reset. COMMON ALARMS 4 key. If key remains illuminated, the unit 3 For manual reset alarms, isolate the affected circuits before further investigation. 4 To reset or delete the alarms displayed in the alarm screen, simply press again. Outlined below is a selection of Common Alarms, a full list is available, please contact Airedale. Phase Rotation or MCCB A normally closed contact. When Phase Rotation is incorrect all controller outputs are de-activated. Emergency Stop A normally open contact. On closing, all controller outputs are de-activated. Evaporator Flow Failure A normally closed contact. On opening, all controller outputs are de-activated. Low Supply Temperature Supply Water Temperature Low Limit alarm is generated when the supply water temperature falls below the low limit value set. All controller outputs are de-activated. INDIVIDUAL CIRCUIT ALARMS Outlined below is a selection of Individual Circuit Alarms, a full list is, please contact Airedale. Electronic Expansion Valve Failure This indicates that the electronic expansion valve controller has detected an operating problem. Low Suction Pressure When the suction pressure sensor value falls below the value set by the low suction level for a period exceeding 1 minute (or 3 minutes on compressor start-up), a visual alarm will be generated at the in-built display and the relevant compressor will be de-activated. High Liquid Pressure When the liquid pressure reaches 14.6 barg, the relevant circuit will be switched off and an alarm activated, this can only be rectified by manual reset via the microprocessor. Compressor Status A normally closed contact when the compressor is operating. If this contact remains open for a period of 5 seconds during operation of the compressor, a visual alarm is generated and the relevant compressor will be de-activated. This alarm comprises of compressor motor protection module, discharge gas thermostat and safety high pressure switch. 42 Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL Commissioning Data GENERAL DATA Operating limits (For 100% Water) Standard Unit Minimum Ambient Air DB °C Maximum Ambient Air DB °C at Full Load Operation Maximum Ambient Air DB °C at Reduced Load Operation Minimum Leaving Water Temperature °C Maximum Return Water Temperature °C Minimum / Maximum ΔT 1 2 -20°C 40°C 45°C +5°C +20°C 4°C / 8°C For conditions outside those quoted, please refer to Airedale. For minimum ambient, it is assumed that adequate freeze protection is fitted. Chillers Installation & Maintenance : 6564868 09/2012 43 OPTICHILL Chillers Commissioning Data OIL & REFRIGERANT CHARGES - HIGH EFFICIENCY OPC500HED8 Compressor Quantity Oil Charge Volume (Total) Oil Type Refrigeration Refrigerant Control Refrigerant Pre Charged Charge (Total) l 1+1 22 + 22 kg 85 + 85 OPC500HEDQ10 Compressor Quantity Oil Charge Volume (Total) Oil Type Refrigeration Refrigerant Control Refrigerant Pre Charged Charge (Total) l kg 1+1 22 + 22 100 + 100 OPC525HED8 OPC550HED8 OPC600HED10 Screw - Twin 1+1 1+1 1+1 19 + 22 19 + 19 19 + 19 Ester Oil Dual Circuit Electronic Expansion Valve (EEV) R134a 90 + 85 90 + 90 105 + 105 OPC525HEDQ10 OPC550HEDQ10 OPC600HEDQ10 Screw - Twin 1+1 1+1 1+1 19 + 22 19 + 19 19 + 19 Ester Oil Dual Circuit Electronic Expansion Valve (EEV) R134a 105 + 100 105 + 105 105 + 105 OPC650HED10 1+1 19 + 19 115 + 115 OPC650HEDQ10 1+1 19 + 19 105 + 105 OIL & REFRIGERANT CHARGES - HIGH EFFICIENCY PLUS OPC500HE+D8 Compressor Quantity Oil Charge Volume (Total) Oil Type Refrigeration Refrigerant Control Refrigerant Pre Charged Charge (Total) Compressor Quantity Oil Charge Volume (Total) Oil Type Refrigeration Refrigerant Control Refrigerant Pre Charged Charge (Total) 44 l 1+1 22 + 22 kg 90 + 90 l kg OPC525HE+D10 OPC550HE+D10 OPC600HE+D10 Screw - Twin 1+1 1+1 1+1 19 + 22 19 + 19 19 + 19 Ester Oil Dual Circuit Electronic Expansion Valve (EEV) R134a 115 + 105 115 + 115 115 + 115 OPC650HE+D10 1+1 19 + 19 120 + 120 OPC500HE+DQ12 OPC525HE+DQ12 OPC550HE+DQ12 OPC600HE+DQ12 OPC650HE+DQ12 Screw - Twin 1+1 1+1 1+1 1+1 1+1 22 + 22 19 + 22 19 + 19 19 + 19 19 + 19 Ester Oil Dual Circuit Electronic Expansion Valve (EEV) R134a 125 + 125 130 + 125 130 + 130 130 + 130 130 + 130 Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL OPC700HED12 OPC750HED12 OPC800HED12 1+1 35 + 19 1+1 35 + 35 1+1 35 + 35 130 + 130 130 + 130 130 + 130 OPC700HEDQ14 OPC750HEDQ14 OPC800HEDQ14 1+1 35 + 19 1+1 35 + 35 1+1 35 + 35 145 + 145 145 + 145 155 + 155 OPC700HE+D12 OPC750HE+D12 OPC800HE+D14 1+1 35 + 19 1+1 35 + 35 1+1 35 + 35 135 + 135 140 + 140 155 + 155 OPC700HE+DQ14 OPC750HE+DQ16 OPC800HE+DQ16 1+1 35 + 19 1+1 35 + 35 1+1 35 + 35 155 + 155 170 + 170 170 + 170 OPC850HED12 OPC900HED14 Screw - Twin 1+1 1+1 35 + 35 35 + 35 Ester Oil Dual Circuit Electronic Expansion Valve (EEV) R134a 135 + 135 160 + 155 OPC950HED14 OPC1000HED16 OPC1100HED16 1+1 35 + 35 1+1 35 + 35 1+1 35 + 35 160 + 160 180 + 180 180 + 180 OPC850HEDQ14 OPC900HEDQ16 Screw - Twin 1+1 1+1 35 + 35 35 + 35 Ester Oil Dual Circuit Electronic Expansion Valve (EEV) R134a 155 + 155 180 + 170 OPC950HEDQ16 OPC1000HEDQ18 OPC1100HEDQ18 OPC850HE+D14 OPC900HE+D16 Screw - Twin 1+1 1+1 35 + 35 35 + 35 Ester Oil Dual Circuit Electronic Expansion Valve (EEV) R134a 155 + 155 180 + 170 OPC950HE+D18 OPC1000HE+D18 OPC1100HE+D18 OPC850HE+DQ18 OPC900HE+DQ20 Screw - Twin 1+1 1+1 35 + 35 35 + 35 Ester Oil Dual Circuit Electronic Expansion Valve (EEV) R134a 185 + 185 215 + 205 OPC950HE+DQ20 OPC1000HE+DQ20 OPC1100HE+DQ20 1+1 35 + 35 1+1 35 + 35 1+1 35 + 35 180 + 180 195 + 195 195 + 195 1+1 35 + 35 1+1 35 + 35 1+1 35 + 35 195 + 195 195 + 195 195 + 195 1+1 35 + 35 1+1 35 + 35 1+1 35 + 35 215 + 215 215 + 215 215 + 215 Chillers Installation & Maintenance : 6564868 09/2012 45 OPTICHILL Chillers Commissioning Data WATERSIDE PRESSURE DROP (KPA) Full design water flow MUST be maintained at all times. Variable water volume is NOT recommended and will invalidate warranty. CAUTION 140 2 1 Waterside Pressure Drop (kPa) 120 100 3 80 4 60 40 20 70 65 60 55 50 45 40 35 30 25 20 15 0 Waterflow (l/s) OPC500 OPC525 OPC550 OPC600 OPC650 OPC700 OPC750 OPC800 OPC850 OPC900 OPC950 OPC1000 OPC1100 (1) (2) 46 HED 1 1 1 1 2 2 2 2 3 3 3 3 3 HEDQ 1 1 1 1 1 2 2 3 3 3 3 3 3 HE+D 2 2 2 2 3 3 4 3 3 3 3 3 3 HE+DQ 2 2 2 2 2 3 3 3 3 3 3 3 3 Chiller pressure drop refers to standard unit only. For pump options, please contact Airedale. For glycol solutions, please refer to Glycol data, on page 26. Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL Commissioning Data PUMP PACKAGES (OPTIONAL EXTRAS) Use the formula below and the graphs provided to calculate the External Head Available: Example Model Ref. Ambient: Fluid Inlet Fluid Temp. Outlet Fluid Temp. Pump Selection Fluid Flow l/s = OPC800HE+D14 = 35°C = 100% Water = 7°C = 12°C (5°C T) = Single Standard Head - Standard ac Motor - Fixed Speed Option = 40.0 l/s EHA (kPa) = External Head Available EHA (kPa) = Total Pump Head Available Unit Waterside Pressure Drop EHA (kPa) = 123 - 33 EHA (kPa) = 90 kPa Chillers Installation & Maintenance : 6564868 09/2012 47 OPTICHILL Chillers Commissioning Data PUMP PACKAGES (OPTIONAL EXTRAS) ac Motor - Fixed Speed Option Total Pump Head Available (kPa) 130 1 120 110 100 90 80 10 15 20 25 30 35 Waterflow (l/s) Total Pump Head Available (kPa) 250 2 200 150 3 4 100 50 10 20 30 40 50 60 70 Waterflow (l/s) HE / HE+ OPC500 OPC525 OPC550 OPC600 OPC650 OPC700 OPC750 OPC800 OPC850 OPC900 OPC950 OPC1000 OPC1100 48 Chillers Installation & Maintenance : 6564868 09/2012 Standard Head 1 1 1 1 1 4 4 4 4 4 4 4 3 Single Head Larger Head 3 3 3 3 2 2 2 2 2 2 2 2 2 Chillers OPTICHILL Commissioning Data PUMP PACKAGES (OPTIONAL EXTRAS) Inverter Driven Motor - Variable Speed Option Total Pump Head Available (kPa) 240 1 220 200 2 180 160 140 120 10 15 20 25 30 35 40 Waterflow (l/s) Total Pump Head Available (kPa) 300 3 250 4 200 5 150 6 100 50 0 10 20 30 40 50 60 70 Waterflow (l/s) HE / HE+ OPC500 OPC525 OPC550 OPC600 OPC650 OPC700 OPC750 OPC800 OPC850 OPC900 OPC950 OPC1000 OPC1100 Single Head Standard Head 2 2 2 6 6 6 6 6 6 5 5 5 5 Larger Head 2 2 2 1 1 1 4 4 4 4 4 3 3 Chillers Installation & Maintenance : 6564868 09/2012 49 OPTICHILL Chillers Commissioning Data ELECTRICAL DATA L1 L1 Compressor Start-Up Information L2 L2 L3 L3 PE PE Key: A B C D E 3 MCCB1 2 4 6 4 MCB8 1 3 5 Power Factor Correction Capacitor Compressor Phase Rotation Relay Closed Transition Start Optional Extra Power Factor Correction Optional Extra L1 L L3 2 E D 1 3 5 CP9 1 3 5 2 4 6 5 2 4 6 CP3 CP1 2 4 6 1 3 2 4 6 1 3 5 MCB12 2 4 6 CP2 2 4 6 1 1 3 C 14 2 4 12 6 E A 3 2 M1 3~ 1 3 3 N L N 7 8 9 N B Starting Sequence (StarDelta Starting) CP5 On CP1 On CP5 Off 2 Sec ± 1(1) Star (1) 50 CP3 On < 40 ms Delta 0.7 seconds when Closed Transition optional extra selected. Chillers Installation & Maintenance : 6564868 09/2012 PRR1 L1 L2 L3 5 OL1 A 3 5 293 294 1 3 5 292 CP7 11 Chillers OPTICHILL Commissioning Data OPERATIONAL SEQUENCE Refrigerant Charge Liquid refrigerant should be charged into the condenser before compressor starting to ensure that refrigerant is present at compressor start-up. Compressor Oil Heater The mains supply to the compressor oil heater should be switched on at least 8 hours prior to compressor starting to avoid refrigerant migration. CAUTION A separately fused, locally isolated, permanent single phase and neutral supply MUST BE FITTED for the compressor oil heater, evaporator trace heating and control circuits, FAILURE to do so could INVALIDATE WARRANTY. To reduce down time, if possible support the above supply with a UPS. Pre-Start-Up Check Before compressor start-up, make sure that an oil level is showing in the compressor sight glass, and that all refrigerant ball valves are opened, including the liquid injection line. Checks at Compressor Start-up As soon as the compressor starts, make sure that the solenoid valve for liquid injection opens, and that the suction and liquid/discharge pressure gauges are showing low and high pressures respectively. CAUTION If there is no liquid present or no differential pressure occurs, isolate immediately. Check phase rotation by connecting pressure gauges to the suction and discharge ports. Capacity Control 4 Stage capacity control CONTROL RELAY START / STOP 25% CAPACITY 50% CAPACITY 75% CAPACITY 100% CAPACITY 1 2 3 4 Solenoid Valve De-energized Solenoid Valve Energized Solenoid Valve intermittent (10 sec on / off) Adding Refrigerant Additional refrigerant should be added to the system via 1/4” Schrader connection on the expansion line. Pump Down Never shut the liquid injection solenoid valve during or before pump down. Never pump down without the low pressure trip and high discharge temperature switches being operative. UNLOADING PROTECTION Head Pressure The microprocessor has inbuilt protection against nuisance trips. If the head pressure rises above 13.2barg the compressor will unload to 75% and remain unloaded until the head pressure drops below 11.2barg. Low Pressure If low pressure drops below the microprocessor setting, the compressor will unload to 75%, if low pressure persists for 1 minute, the circuit will be switched off and sound an alarm. Chillers Installation & Maintenance : 6564868 09/2012 51 OPTICHILL Chillers Commissioning Procedure To be read in conjunction with the commissioning sheets provided, items highlighted should be recorded. GENERAL CAUTION Please ensure all documents have been completed correctly and return to Airedale Technical Support immediately to validate warranty. PRE COMMISSIONING CHECKLIST CAUTION ALL work MUST be carried out by Technically Trained competent personnel. The equipment contains live electrical and moving parts, ISOLATE prior to maintenance or repair work. The unit isolators DO NOT isolate the incoming mains supply, but isolate the individual electrical panels. Isolate REMOTELY the mains incoming supply to the BUSBAR chamber prior to maintenance or repair work. The door interlocking MCCB should be in the OFF position and the auxiliary alarm contact from the MCCB should be linked out. Ensure all items listed in the Pre commissioning section are complete. RECORD CAUTION The unit should be visually inspected and any damage noted Secure commissioning gauges to the high side of the system, check for a positive charge Check tightness of electrical components and properly terminated Check that the remote on/off switch (if fitted) is in the off position With the MCBs in the off position measure the incoming voltage Check Phase Rotation Check voltage at permanent supply Measure and record the primary (230V) and secondary (24V) voltages at each of the transformers, adjust tapping if necessary and record on the commissioning document Check all timer settings are correct Check compressor oil heater (ensure this is switched on for a minimum of 8 hours prior to the unit operation) Check oil level of each compressor Check water filter is fitted Check design water flow is available Check flow switch and pump interlocks are fitted to the water system and wired directly to the chiller and functioning correctly Switch on the controls and individual circuits, primary and secondary, MCBs to the ON position, at this stage the control display panel should be illuminated Record Optional Extras Record Controller Data Disable remote ON/OFF to ensure the unit does not start unintentionally. The chiller will not start until microprocessor control SWITCH 1 is in the ON position. DO NOT SWITCH TO ON AT THIS STAGE 52 Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL Commissioning Procedure PRE COMMISSIONING CHECKLIST Adjust the water temperature supply and return set points (if necessary) to call for 100% cooling (refer to Controls, on page 39). Ensure all KNOBS and SWITCHES are adjusted to suit the design requirements (refer to Controls, on page 39) To switch the unit ON, use the microprocessor keypad as follows: Press CAUTION Prg , press , press , press & finally There will always be a delay between the enabling of the unit and the energising of the compressor contactors, anything between 1 to 2 minutes. Be patient. Check that there is a 2 seconds delay between the Star and Delta contactor energising on each circuit. CAUTION CAUTION This delay period would be 0.7 seconds in Closed Transition Starting. Check capacity control timing as detailed previously Check that each circuit trips on low pressure, the alarm should appear within 3 minutes The alarm will be recognised at the display circuit trip, to clear the alarms refer to Alarm Handling, on page 42 Prior to the chiller compressors being allowed to start, the Water Flow Fail and Pump Interlock features MUST both be proven to work correctly. To check the water flow fail safety protection is working satisfactorily: RECORD Reduce the flow rate to 75% of design and ensure that the evaporator pressure or flow protection switch trips at this flow rate, adjust as necessary With compressors off, ensure this alarm is recognised as “Water Flow Fail” at the display and disengages the circuits operation immediately, restore flow rate to the design and check the alarm has self-cleared To check the pump interlock safety feature works satisfactorily: RECORD Switch off the chiller water pump and check the interlock wiring connections at the chiller are open circuit To switch the unit OFF, use the microprocessor keypad as follows: Press CAUTION Prg , press , press , press & finally Fully open all liquid line and discharge service ball valves on each circuit Re-instate both the liquid injection and liquid line solenoid valves. Remove the link from the MCCB for the auxiliary alarm contact. Fully open all liquid line and discharge service ball valves on each circuit. Chillers Installation & Maintenance : 6564868 09/2012 53 OPTICHILL Chillers Commissioning Procedure COMMISSIONING CHECKLIST The following should be carried out with a load on the system; otherwise the unit is likely to short cycle. The following tests are to be carried out on 1 circuit at a time. Switch the door interlocking MCCB to the ON position but again only on the circuit which is to be tested Adjust the water temperature supply and return set points to match the system requirements To switch the unit ON, use the microprocessor keypad as follows: Press Prg , press , press , press & finally Check liquid injection solenoid valve is energised and sight glass is clear Check pressures at suction and discharge ports for correct phase rotation CAUTION If there is no liquid present or no differential pressure occurs, isolate immediately. RECORD CAUTION RECORD Check the unloading solenoids operate in the correct sequence - refer to Commissioning Data, on page 51 Measure and record the compressor amps once the compressors are fully loaded and then at each of the unloading stage Measure and record full speed amps of each condenser The microprocessor LP setting is adjustable via the micro display. It is recommended that this setting be 0.6 bar below the equipment freezing point of the cooling medium ie for water (no glycol) LP micro settings is 3.2barg. Ensure that the low water temperature safety cuts out at the correct setting +/- 0.5°C, to clear the alarms refer to Alarm Handling, on page 42 For water (no glycol) application, the recommended setting is 3°C below the design supply water temperature (to a minimum of 3°C) Check the liquid line sight glass is clear and dry Check the superheat setting adjust the expansion valve to maintain a superheat setting of 5 - 8°C at all operating loads Check and record the following: Suction and discharge pressures Liquid, discharge and suction line temperature Water inlet and outlet temperature Ensure the above are all within the design parameters Repeat as follows for each circuit: To switch the unit OFF, use the microprocessor keypad as follows: Press Prg , press , press , press & finally To switch the unit ON, repeat above The unit is now commissioned and will provide many years of trouble free operation providing the following maintenance schedule is followed. 54 Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL Maintenance CAUTION WARNING ALL work MUST be carried out by technically trained competent personnel. The equipment contains live electrical and moving parts, ISOLATE prior to maintenance or repair work. The unit isolators DO NOT isolate the incoming mains supply, but isolate the individual electrical panels. Isolate REMOTELY the mains incoming supply to the BUSBAR chamber prior to maintenance or repair work. The door interlocking MCCB should be in the OFF position and the auxiliary alarm contact from the MCCB should be linked out. WARNING Power Factor Correction - Optional Extra Allow Discharge time and short circuit the capacitor before handling! This applies to any flying leads directly attached to the capacitor terminals. IMPORTANT UK MAINLAND - The Chiller Maintenance Record and supporting maintenance documents MUST be complete and available on request to validate warranty. The Chiller Maintenance Record is located within the unit control panel. IMPORTANT Ensure relevant F-Gas Regulation checks are carried out at the appropriate period. Chillers Installation & Maintenance : 6564868 09/2012 55 OPTICHILL Chillers Maintenance The maintenance schedule indicates the time period between maintenance operation. GENERAL MAINTENANCE 3 MONTHS ACTION NOTES REFRIGERATION Check the following and compare results with commissioning records: Suction and discharge readings Head pressure control is maintained Pressure relief indicator gauge Check each circuit sight glass for dryness and bubbles for indication of leaks Check compressor oil level and shell/sump temperature Visually inspect the unit for oil patches Investigate and rectify variations SYSTEM Check the following against the commissioning records: Control settings Alarm log for unusual occurrences Chilled water control maintains design temperature Chilled water flow is within design limits of zero to plus 10% Concurrently ensure chilled water pump and flow switch operate efficiently, and that interlocks function correctly Operation of waterflow switch and pump interlock Investigate and adjust as necessary. Finally! Record operating conditions. FABRIC Visually inspect the unit for general wear and tear, treat metalwork. Rust should be inhibited, primed and touched up with matching paint (available from Airedale or your Distributor). Visually inspect pipe and pipework insulation. Repair/rectify as necessary. Clean evaporator water strainer. At first maintenance visit and then as frequently as necessary (12 months). Remember to re-cap the Schrader connections! Investigate and repair possible leaks Clean condenser coils. Do not steam clean use Do not damage fins and comb out if detergent and stiff bristled brush. For heavy dirt, necessary. use either a high pressure water or chemical hose. Visually check the following: Pipework clamps are secure Tightness and condition of fan and compressor mounts Anti-Vibration mounts fixings (if fitted) Finally! 56 Ensure control panel lids and access panels have been correctly replaced and securely fastened in position. Chillers Installation & Maintenance : 6564868 09/2012 Secure/tighten as necessary. Chillers OPTICHILL Maintenance GENERAL MAINTENANCE 6 MONTHS ACTION NOTES Repeat 3 month checks plus the following: SYSTEM Check evaporator heater and low ambient thermostat are set to activate at 4.0ºC. Remember to re-cap the Schrader connections! 12 MONTHS ACTION NOTES Repeat 6 month checks plus the following: SYSTEM Check safety devices cut out the compressor at the correct settings. REFRIGERATION Check glycol concentration if appropriate. Leak test all refrigerant joins and inspect all water connections. ELECTRICAL Adjust as necessary. Rectify as necessary. Tighten all electrical terminals. COMPRESSOR MAINTENANCE SHUT DOWN PERIODS Periodic maintenance and inspection of this equipment is necessary to prevent premature failure, the following periodic inspections should be carried out by period or hourly use which ever is sooner. 1 Year Measure compressor motor insulation. 7,500 Hours or 4 Years Inspect compressor oil. 20,000 Hours or 4 Years Inspect oil filter, suction filter, check valve and pressurerelief valve. For periods of winter shut down the following precautions are recommended: Close the liquid and discharge ball valve Cap service ports Turn off electrical circuits Drain the water from the chiller evaporator via the evaporator drain plug Chillers Installation & Maintenance : 6564868 09/2012 57 OPTICHILL Chillers Parts Identification SPARES For ease of identification when ordering spares or contacting Airedale about your unit, please quote the unit type, unit serial number and the date of manufacture, which can be found on the unit serial plate. A spares list for 1, 3 and 5 years will be supplied with every unit and is also available from our Spares department on request. The serial plate can be located inside Item 31. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 31 30 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 58 Suction Pressure Transducer Low Pressure Switch HP Switch Liquid Line Sight Glass Discharge Line Ball Valve Discharge NRV Discharge Schrader Connection Discharge Thermostat Switch Compressor Liquid Line Ball Valve Liquid Line Filter Drier Electronic Expansion Valve Controller Microprocessor Controller Phase Rotation Relay Bus bar Chamber 3 phase Mains Incoming Closed Transition Starting Resistor Pack (Optional Extra) Condenser Fan Motor Protection Circuit Breakers Modulating Head Pressure Controller - AC Standard Fans only Timers Door Interlocking Circuit Isolator Star Delta Contactors Incoming Customer Terminals Evaporator Water Connection Electronic Expansion Valve (EEV) Liquid Line Mains Electrics & Controls Panels Fan & Motor Assemblies - AC Motor Standard, EC Motor Optional Condenser Coils Control Panel (Serial Plate to inside) Mains Panel Circuit 2 Emergency Stop Incoming Customer Mains Access Points Suction Port Compressor Electrical Terminal Box Unloading Solenoid Valve 1 Discharge Line Unloading Solenoid Valve 2 Unloading Solenoid Valve 4 Oil Level Sight Glass Compressor Feet/Resilient Pads Unloading Solenoid Valve 3 Oil Sump Draw Point Sump Heater Economiser Circuit Economiser EEV Liquid Line Solenoid Valve Economiser Liquid Transducer Economiser Plate Heat Exchanger Chillers Installation & Maintenance : 6564868 09/2012 Chillers OPTICHILL 16 17 18 5 19 6 1 12 7 2 8 20 6 13 21 14 22 3 4 9 23 10 25 9 26 24 15 11 27 28 29 30 31 32 20 15 33 33 9 45 37 34 35 33 36 38 39 40 41 42 44 46 47 48 49 43 Chillers Installation & Maintenance : 6564868 09/2012 59 W here to Fin d U s Head Office: Airedale International Air Conditioning Ltd Leeds Road Rawdon Leeds LS19 6JY United Kingdom Tel: Fax: e-mail: website: LITER ATUR E ORDER COD E PART NO: 6564868 (IM E) 6564868 (IM E) ISSUE 08/2008 09/2012 +44 (0) 113 239 1000 +44 (0) 113 250 7219 [email protected] www.airedale.com UT AIRED AL E
© Copyright 2024