6. 7. 8. 9. 10. 11. 12. 13. 14. SAVE-A-LOT FOOD STORES 15. 16. TENANT FIT OUT 1612 MILL SQUARE ALEXANDER CITY, AL 35010 17. 18. DATE: C "COMPANY NAME" 20XX ALL RIGHTS RESERVED 5. PRELIMINARY NOT FOR BID OR CONSTRUCTION 4. DESCRIPTION: 3. REV. NUMBER: 2. PREMISES ARE TO BE FREE FROM ASBESTOS AND OTHER HAZARDOUS SUBSTANCES AND GASES, ANY SUCH ASBESTOS AND OTHER HAZARDOUS SUBSTANCES AND GASES SHALL BE REMOVED (ACCORDING TO ALL APPLICABLE LAWS) PRIOR TO THE START OF WORK. THE BUILDING OWNER WILL PROVIDE A "VANILLA BOX" TO SAVE-A-LOT. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE OWNER'S CONTRACTOR WITH RESPECT TO ANY LEASEHOLD WORK THAT IS TO BE PERFORMED PRIOR TO COMPLETION OF THE "VANILLA BOX." DURING THE BIDDING PERIOD, EACH CONTRACTOR SHALL BE HELD RESPONSIBLE TO VISIT THE SITE AND VICINITY TO ACQUAINT THEMSELVES WITH THE EXISTING CONDITIONS, FACILITIES AND OBSTRUCTIONS INVOLVED IN AND EXPECTED BY THE WORK INDICATED BY ALL CONTRACT DOCUMENTS IN ORDER TO PROVIDE A COMPLETE AND ACCURATE BID. CONTRACTOR'S FAILURE TO REASONABLY DETERMINE AND/OR ANTICIPATE THE EFFECT OF EXISTING CONDITIONS AND INVOLVEMENT SHALL NOT BE JUSTIFICATION FOR ADDITIONAL COMPENSATION. PROVIDE" MEANS "FURNISH AND INSTALL." CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY ARCHITECT OR SAVE-A-LOT PROJECT MANAGER OF DISCREPANCIES. CONTRACTOR HAS SOLE RESPONSIBILITY OF FIELD VERIFYING DIMENSIONS PRIOR TO ORDERING MATERIALS. CONTRACTOR TO COORDINATE NEW SCOPE OF WORK REQUIREMENTS W/ ALL DISCIPLINES WITHIN THIS SET OF DRAWINGS. CONTRACTOR TO INVESTIGATE EXISTING CONDITIONS THOROUGHLY AND IDENTIFY CONFLICTS, IF ANY, AS EARLY AS POSSIBLE DURING CONSTRUCTION IN ORDER TO RESOLVE CONFLICTS AS QUICKLY AS POSSIBLE NOTIFY PROJECT MANAGER OF ANY STRUCTURAL DEFECTS OR CONDITIONS WITHIN THE LEASED PREMISES IF DISCOVERED DURING THE BUILD-OUT OF THE LEASED PREMISES. CONTRACTOR SHALL PROVIDE NECESSARY BARRIERS TO CONTAIN DUST / DEBRIS DURING CONSTRUCTION. CONTRACTOR SHALL REMOVE DEBRIS FROM WORK AREA EACH DAY PRIOR TO LEAVING SITE. CONTRACTOR SHALL PROVIDE FINAL CLEANING OF STORE AT END OF CONSTRUCTION. INCLUDING, BUT NOT LIMITED TO, SALES AREA, OFFICE, BREAK ROOM, REST ROOMS, BACK ROOM AREAS, COOLERS, FREEZERS, STORE FRONT GLAZING AND DOORS. PROVIDE DUST PARTITION TO PROTECT EQUIPMENT AND ADJACENT, NON-WORK AREAS USE ELECTRIC OR PNEUMATIC POWERED EQUIPMENT FOR INTERIOR WORK. DO NOT USE EQUIPMENT THAT PRODUCES EXHAUST FUMES. ALL WOOD, WOOD FRAMING AND WOOD BLOCKING NECESSARY FOR PLUMBING FIXTURES, TOILET ACCESSORIES, TIME-CLOCK, SHELVING, DOOR STOPS, ETC. SHALL BE FIRE RETARDANT WOOD. CONTRACTOR SHALL REMOVE / REPLACE OR USE A FIRE RETARDANT COATING APPLICATION (SUCH AS FLAMEX FS-II) ON ALL NON FIRE-RETARDANT WOOD EXPOSED DURING CONSTRUCTION. VISUALLY INSPECT THE ROOF FOR DAMAGE OR NEED OF REPAIR PRIOR TO BEGINNING ANY WORK ON THE ROOF. IDENTIFY AND PHOTOGRAPH ANY EXISTING DAMAGE OR PROBLEM AREAS, AND REPORT TO SAVE-A-LOT PROJECT MANAGER. CONTRACTOR SHALL PROVIDE NECESSARY CUTTING AND PATCHING AT ALL PENETRATIONS FOR PLUMBING, HVAC AND ROOF HATCH. IN ORDER TO PRESERVE THE ROOFING WARRANTY, THE CONTRACTOR THAT INSTALLED THE ROOF SHOULD PERFORM THE WORK. OTHERWISE, HAVE THE WORK PERFORMED BY A LICENSED ROOFING CONTRACTOR THAT IS APPROVED BY BOTH THE ROOFING MANUFACTURER AND THE LANDLORD. CONTRACTOR SHALL PROVIDE ALL ROOF PENETRATIONS PER NEW REFRIGERATION EQUIPMENT AND ASSOCIATED STRUCTURAL, MECHANICAL AND ELECTRICAL PER MANUFACTURER'S SPECIFICATIONS. SEE DETAILS 15 & 16 / A-4. CONTRACTOR SHALL REPAIR ALL ROOF DAMAGE CAUSED BY EQUIPMENT INSTALLATION, REMOVAL OR RELOCATION. CONTRACTOR SHALL REMOVE ALL DEBRIS FROM ROOF. CONTRACTOR SHALL COORDINATE REFRIGERATED CASE LOCATIONS w/ SAVE-A-LOT PROJECT MANAGER AND REFRIGERATION DRAWINGS - TYPICAL. CONTRACTOR SHALL PROVIDE A SMOOTH, CLEAN AND LEVEL EXISTING CONCRETE FLOOR READY FOR INSTALLATION OF NEW FLOOR FINISHESSAVE-A-LOT HAS A NATIONAL ACCOUNT AGREEMENT WITH PASS SECURITY WHICH SECURES FAVORED PRICING FOR THE INSTALLATION & MONITORING OF FIRE AND INTRUSION ALARM SYSTEMS. ALL ALARM SYSTEMS SUBMITTED OR PROPOSED MUST BE APPROVED BY THE SAVE-A-LOT PROJECT MANAGER & PASS SECURITY. FOR QUESTIONS REGARDING SPECIFICATIONS REQUIRED CONTACT TONY RUSTEBERG AT PASS SECURITY, 141 MARKET PLACE DRIVE, SUITE 104, FAIRVIEW HEIGHTS, IL 62208. PHONE: (314) 241-0422 EXT 155 OR (618) 708-0097. COOLERS AND FREEZERS ARE PROVIDED AND INSTALLED BY SAVE-A-LOT. CONTRACTOR SHALL PROVIDE AN AS-BUILT, RECORD SET OF DRAWINGS TO SAVE-A-LOT PROJECT MANAGER AT PROJECT COMPLETION. ONE FULL SIZE SET & FULL SET OF PDF FILES ON CD. CERTIFICATION: 1. BY: GENERAL NOTES SHEET INDEX SHT. NO. DESCRIPTION CS-1 COVER SHEET F-1 FIXTURE PLAN - (FOR REFERENCE ONLY) ARCHITECTURAL DRAWINGS ELECTRICAL CODE: 2005 INTERNATIONAL ELECTRICAL CODE. MECHANICAL CODE: 2006 INTERNATIONAL MECHANICAL CODE. FIRE CODE: 2006 INTERNATIONAL FIRE CODE. HANDICAP ACCESSIBILITY: ALABAMA ACCESSIBILITY CODE (ADAAG WITH PROVISIONS). ENERGY CODE / CALCULATIONS: 2006 INTERNATIONAL ENERGY CODE. CONSTRUCTION CLASSIFICATION: -------------------------------- TYPE IIB (NO CHANGE TO EXISTING) FIRE MARSHALL ALEXANDER CITY FIRE DEPARTMENT CRAIG CLARK 38 COURT SQUARE ALEXANDER CITY , AL 35010 PHONE: (256) 329-6760 WATER SERVICE / SANITARY SEWER ALEXANDER CITY SEWER DEPARTMENT MIKE WALDROP, SUPERVISOR 762 RAILEY ROAD, ALEXANDER CITY, AL 35010 PHONE: (256) 409-2000 USE GROUP: -------------------------------------------------------------- GROUP M - (EXISTING - NO CHANGE) MERCANTILE SINGLE STORY w/ MEZZANINE ----- (EXISTING - NO CHANGE) AREA CALCULATIONS: GROUND FLOOR: ----------------------------------------------------------------------------------------17,158 SF MEZZANINE: ----------------------------------------------------------------------------------------------2,440 SF NORTH SITE LOCATION PROJECT DESCRIPTION THIS PROJECT IS A TENANT FIT-OUT / REMODEL OF A PORTION OF A FORMER RETAIL BUILDING. THE WORK WILL INCLUDE INTERIOR FIXTURE / EQUIPMENT MODIFICATIONS / INSTALLATIONS AFTER SUB-DIVIDING THE EXISTING SPACE. MODIFICATIONS TO THE INTERIOR WILL BE MADE FOR INCORPORATION IN THE NEW LAYOUT OF THE SPACE. IN ADDITION, PLUMBING, MECHANICAL, FIRE SPRINKLER SYSTEM AND ELECTRICAL MODIFICATIONS WILL BE REQUIRED TO ACCOMMODATE THE NEW REQUIREMENTS FOR THE PROPOSED GROCERY STORE. ALSO, INCLUDED IN THE REMODEL WILL BE EXTERIOR SIGNAGE AND REPAINTING THE MAIN CANOPY SIGN FACADE. FIRST FLOOR OCCUPANT LOAD: TABLE 1004.1.2 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT: AREA LOAD FACTOR MERCANTILE (SALES) AREA: 11,808 SF ( / 30) STORAGE: 4,444 SF ( / 300) MECHANICAL: 26 SF ( / 300) OFFICE: 199 SF ( / 100 PREP: 479 SF ( / 200) ASSEMBLY: 158 SF ( /15) TOTAL FIRST FLOOR OCCUPANT LOAD: OCCUPANTS = 393.6 = 14.8 = .1 = 1.1 = 2.4 = 10.5 = 422.5 MEZZANINE OCCUPANT LOAD: TABLE XXX MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT: AREA LOAD FACTOR MECHANICAL: 2440 SF ( / 300) OFFICE: 0 SF ( / 100 ASSEMBLY: 0 SF ( /15) TOTAL MEZZANINE OCCUPANT LOAD: OCCUPANTS = 2.2 = 0 = 0 = 8.1 TOTAL OCCUPANTS: = 431 HEALTH DEPARTMENT TALLAPOOSA COUNTY HEALTH DEPARTMENT BRIDGET KING 2078 SPORTPLEX BLVD. ALEXANDER CITY, AL 35010 PHONE: (256) 329-0531 ELECTRICAL DEPARTMENT ALEXANDER CITY LIGHT & POWER DEPARTMENT GEORGE EAST 762 RAILEY ROAD, ALEXANDER CITY, AL 35010 PHONE: (256) 409-2080 I.D. IN. INT. LBS. MAX. MFR. MIN. EGRESS WIDTH PER OCCUPANT SERVED: TABLE 1005.1 REQUIRED: MAIN FLOOR: 423 OCCUPANTS x 0.15 EGRESS WIDTH FACTOR = 63.5 INCHES MEZZANINE: 8 OCCUPANTS X 0.2 EGRESS WIDTH FACTOR = 1.6 INCHES TOTAL REQUIRED: = 65.1 INCHES = 6'-5" EXIT WIDTH PROVIDED: 80" INCHES = 6'-7" (DIRECT FROM SALES FLOOR) 1-FRONT DOOR @ 3'-10" = 46 INCHES 1-SALES EMERGENCY EXIT 1 @ 2'-10-"=34 INCHES MAXIMUM TRAVEL DISTANCE - 250 FEET (165' ACTUAL) REQUIRED PLUMBING FIXTURES : (IBC TABLE 2902.1) WATER CLOSETS - 1 FIXTURE PER 500 OCCUPANTS, 431 TOTAL OCCUPANTS WOMEN: 1 REQUIRED, 3 PROVIDED MEN: 1 REQUIRED, 1 PROVIDED LAVATORY: WOMEN: 1 REQUIRED, 2 PROVIDED MEN: 1 REQUIRED, 2 PROVIDED DRINKING FOUNTAIN: 1 REQUIRED, 1 PROVIDED MOP SINK: 1 REQUIRED, 1 PROVIDED FIRE SAFETY SYSTEMS: SPRINKLER SYSTEM (EXIST.) YES X NO _ SPRINKLER SYSTEM (EXT. CANOPY) YES _ NO X EMERGENCY LIGHTING & EXIT SIGNS YES X NO _ FIRE ALARM YES X NO _ SMOKE DETECTIONS SYSTEMS YES X NO _ PANIC HARDWARE YES X NO _ FIRE EXTINGUISHERS: YES X NO _ LOCATED IN QUANTITY AND LOCATIONS DIRECTED BY FIRE MARSHAL PROJECT DIRECTORY TENANT JESUS ROLON, PROJECT MANAGER SAVE-A-LOT, LTD. 100 CORPORATE OFFICE DRIVE EARTH CITY, MO 63045 PHONE: 407-433-6754 eMAIL: [email protected] ARCHITECTURAL GREG THOMPSEN STORE DESIGN SERVICES 6533 FLYING CLOUD DR, SUITE 100 EDEN PRAIRIE, MN 55344 PHONE: 952 914 5832 FAX: 952 914 5850 eMAIL: [email protected] STRUCTURAL ENGINEER TOM PETERSON STORE DESIGN SERVICES 6533 FLYING CLOUD DR. SUITE 100 EDEN PRAIRIE, MN 55344 PHONE: 952 914 5833 FAX: 952 914 5850 eMAIL: [email protected] MISC. M.O. MT'D. MT'G. N.I.C. NO. NTS. O.C. O.D. OPNG. OPP. O.S.B. P.L.F. P.S.F. P.S.I. R.C.P. RE: REINF. REQ'D R.O. SIM. SPECS. STL. STRUC. SQ. T&G T.C. T.O. T.D. TYP. VERT. U.L. U.D.L. W/ W.P. W.W.F. MISCELLANEOUS MASONRY OPENING MOUNTED MOUNTING NOT IN CONTRACT NUMBER NOT TO SCALE ON CENTER OUTSIDE DIMENSION OPENING OPPOSITE ORIENTED STRAND BOARD POUNDS PER LINEAL FOOT POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH REFLECTED CEILING PLAN REFER TO, REFERENCE FROM REINFORCING REQUIRED ROUGH OPENING SIMILAR SPECIFICATIONS STEEL STRUCTURAL SQUARE TONGUE & GROOVE TOP OF CURB/CONCRETE TOP OF TOP OF DRAIN TYPICAL VERTICAL UNIFORM LOAD UNIFORM DISTRIBUTED LOAD WITH WEATHERPROOF WELDED WIRE FABRIC A-4 DETAILS A-5 DOOR AND ROOM FINISH SCHEDULES AND NOTES STRUCTURAL DRAWINGS S-1 STRUCTURAL NOTES AND DETAILS S-2 STRUCTURAL PLAN PLUMBING DRAWINGS P-1 DRAIN, WASTE AND VENT PLAN P-2 ABOVE GROUND PIPING PLAN P-3 PLUMBING SCHEDULES P-4 PLUMBING DETAILS MECHANICAL DRAWINGS M-1 HVAC PLAN M-2 HVAC SCHEDULES AND DETAILS FIRE PROTECTION FP-1 ELECTRICAL DRAWINGS E-0 ELECTRICAL DEMOLITION PLAN E-1 LIGHTING PLAN E-2 POWER PLAN E-3 REFRIGERATION POWER PLAN E-4 ENLARGED POWER PLAN AND DETAILS E-5 RISER DIAGRAM AND SCHEDULES SYMBOL LEGEND ELECTRICAL BIFTU RUMICHO STORE DESIGN SERVICES 6533 FLYING CLOUD DR. SUITE 100 EDEN PRAIRIE, MN 55344 PHONE: 952 914 5511 FAX: 952 914 5850 eMAIL: [email protected] MECHANICAL RALPH CADMUS STORE DESIGN SERVICES 6533 FLYING CLOUD DR, SUITE 100 EDEN PRAIRIE, MN 55344 PHONE: 952 914 5806 FAX: 952 914 5850 eMAIL: [email protected] XX X-X XX X-X DETAIL SECTION 101 116A 07 XX X-X ELEVATION FIRE PROTECTION PLAN REFRIGERATION DRAWINGS ROOM NUMBER DOOR NUMBER KEY NOTE INDICATOR XXX N A 1 EQUIPMENT LIST 1 of 9 FIXTURE PLAN - (FOR REFERENCE ONLY) 2 of 9 ELECTRICAL DRAIN PLAN - (FOR REFERENCE ONLY) 3 of 9 REFRIGERATION PIPING DETAILS - (FOR REFERENCE ONLY) 4 of 9 REFRIGERATION DETAILS - (FOR REFERENCE ONLY) 5 of 9 REFRIGERATION CASE DETAILS - (FOR REFERENCE ONLY) 6 of 9 CASE MISTING SYSTEM - (FOR REFERENCE ONLY) 7 of 9 DAN FOSS COMPONENTS - (FOR REFERENCE ONLY) 8 of 9 POP SHEETS - (FOR REFERENCE ONLY) 9 of 9 REFRIGERATION WIRING DETAILS - (FOR REFERENCE ONLY) PROJECT NUMBER COLUMN GRID REVISIONS STORE NUMBER 03510-01 SHEET TITLE COVER SHEET SHEET NUMBER CS-1 ALEXANDER CITY, AL 2006 INTERNATIONAL PLUMBING CODE. ANCHOR BOLT ACOUSTIC CEILING PANEL ABOVE FINISHED FLOOR AND ALUMINUM ARCHITECTURAL BUILDING BOTTOM OF BEARING CENTER LINE CUBIC FEET PER MINUTE CONTROL JOINT CONCRETE MASONRY UNITS COLUMN CONCRETE CONTINUOUS CYLINDER DIAMETER EACH ELEVATION EXTERIOR INSULATING FINISH SYSTEM EXISTING EXTERIOR FOUNDATION FINISHED OPENING FACE OF CURB/CONCRETE FACE OF MASONRY FINISHED FLOOR FEET FOOTING FIRE-RETARDANT GAUGE GALVANIZED GALVANIZED IRON OR STEEL GENERAL CONTRACTOR GLUE LAMINATED STRUCTURE MEMBER GYPSUM BOARD GYPSUM WALL BOARD HEADED CONCRETE ANCHOR HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING VENTILATING AND AIR CONDITIONING INSIDE DIMENSION INCH INTERIOR POUNDS MAXIMUM MANUFACTURER MINIMUM ENLARGED FLOOR PLANS AND EXTERIOR ELEVATION 08/23/10 PLUMBING CODE:. A.B. A.C.P. A.F.F. & ALUM. ARCH. BLDG. B.O. BRG. C.L. CFM C.J. CMU COL. CONC. CONT. CYL. DIA. EA. ELEV. E.I.F.S. EXIST. EXT. FDN. F.O. F.O.C. F.O.M. F.F. FT. FTG. FR. GA. GALV. G.I. G.C. G.L. GYP. BD. GWB. H.C.A. H.D. HORIZ. HR. HT. HVAC A-3 DATE: 2006 INTERNATIONAL BUILDING CODE. SIGNAGE ALEXANDER CITY BUILDING DEPARTMENT STEVE MORGAN, ENFORCEMENT OFFICER 4 COURT STREET, P.O. BOX 552 ALEXANDER CITY, AL 35011 PHONE: (256) 329-6706 FAX: (256) 329-6711 REFLECTED CEILING PLAN 1612 MILLS SQUARE BUILDING CODE: BUILDING DEPARTMENT CITY OF ALEXANDER CITY BUILDING DEPARTMENT GAINES HODNETT 4 COURT SQUARE, P. O. BOX 552 ALEXANDER CITY, AL 35011-0552 PHONE: (256) 329-6712 FAX: (334) 688-2016 A-2 GAT BUILDING CODE DATA: ABBREVIATIONS FLOOR PLAN CHECKED: GOVERNMENTAL AGENCIES A-1 JBS CODE / PROJECT DATA DEMOLITION PLAN DRAWN: SITE MAP A-0 BY: E C D B A 174'-2" 30'-8" 30'-0" 12'-2" 149'-7" 14'-8" 134'-11" SOFFIT 16'-0" UP 6" RECESSED HOSE BIBB 36" A.F.F. FOR PRODUCE MISTING SYSTEM & CASE CLEAN-OUT FUTURE CHECKSTAND CART STORAGE CE DU PRO 8-30" FROZEN 10-30" DOORS @ ICE CREAM TEMP. FOOD DOORS 21'-3" 43'-0" 58'-11" CHG B/B/F 36" EP 4-DRAWER FILE OFFICE 10'X13' 3-SHELF STORAGE CABINET 08/23/10 BUILT-IN COUNTERS DEP 1'-0" 16' ROLL-IN BREAD 4-DRAWER FILE 3-SHELF STORAGE CABINET ADD 24"X36" WINDOW BREAK ROOM 15'X9' 4 1'-0" 28' 4-DECK DAIRY CASE LIT DEB MOP SINK PANELS DOOR 1'-0" ELECTRICAL 36" AS SHOWN 3 3-SHELF STORAGE CABINET LAST CHANCE 6'X8' EXISTING 4'-6" DOORS SWING DRAWN: FUTURE 12' BEER CASE ELECTRIC REQUIRED 27'-0" 27-30" FROZEN FOOD DOORS 13'-9" 20' BAKERY/LUNCHBOX 3-30" DRS PROMO HOLD HOLD 11'-0" 10'-0" 6-DOOR DAIRY COOLER 18'X21' 54" 3-30" DRS PROMO 68' EXIST. COILING 4" 66" A.F.F. '-7 10 1/ BUILD WALL 9'-0" 4'-7" 3'-0" TYP 20'-0" (N) EWC 3 BAY SINK PRODUCE AREA HS 20'-0" (E) GAS METER BELT 1 36" ONE-WAY MIRRORED SECURITY WINDOW 52" WALL HEIGHT BELT 2 64' (E) SPRINKLER RISER ICE MERCH NEW AUTO 24 LF OF BAGGING TABLES CANDY BELT 3 REPLACE 42" DOORS W/ 12'-0" 10'-9" TYP 6'X8' 6'X8' WALK-OFF CARPET TILES 62' 5'-10 1/2" 2 FINISH TO BE BELT 4 4'-0" 5'-10 1/2" 66" A.F.F. 25'-10" 8'-0" 9'-11 3/4" 8'-0" PRODUCE COOLER 14'X14' BUILD WALL 4' ACCESSIBLE CHECKLANE C L 31'-8" CE EUR TAB O EU R L 4'X E TAB O EU 4' R L 4'X E TAB O 4' L 4'X E 4' DU PRO DRY LF BI NS 62' 8'-0" (E) CONC COOLER SLAB @ F.F.E. 14'-1" 14'-1 1/2" TABLE 48"X30" TABLE 72"X30" WRAPPER TABLE 72"X30" FREEZER 24'X10' CUBER 36" 54" HA LF NS BI SAW 58' SLICER RAMP UP HARDWARE REMOVE DOORS & CLOSE & LOCK 5'-0" TABLE 72"X30" 36" STRIP CURTAIN TABLE 72"X30" 36" STRIP CURTAIN (8) 24"X12" RACKS 8' 3-DECK 36" 84'-8" TRAINING EXISTING ROOM 54" 54" MEAT PREP 26'X13' 15'-0" HA B/B/F MEAT COOLER 14'X17' 3 BAY SINK BAKERY TABLE PRINTER (E) CONC FREEZER SLAB @ -4" BELOW F.F.E. HS 44' PROMOTIONAL ITEMS FAX/ PHONE (N) CONC STOOP CERTIFICATION: 1 32' 1-DECK WITH INSERTS & MISTERS FRESH PRODUCE CASE 90'-1" (E) CONC FREEZER SLAB @ -4" BELOW F.F.E. DATE: 1'-0" 33'-1" PRELIMINARY NOT FOR BID OR CONSTRUCTION 15'-0" 30'-0" CHECKED: 20'-9" 30'-0" 12'-2" REV. NUMBER: 20'-5" C "COMPANY NAME" 20XX ALL RIGHTS RESERVED DATE: F DESCRIPTION: G 8" 11'-1" 3'-11" 1'-0" 137'-5" 1'-0" 189'-3" REAR NORTH RIGHT FRONT LEFT ALEXANDER CITY, AL 1'-0" 20'-1" 1612 MILLS SQUARE 14'-1" STORE NUMBER PROJECT NUMBER 03510-01 SHEET TITLE FIXTURE PLAN FOR REFERENCE ONLY SHEET NUMBER F-1 1 FIXTURE PLAN SCALE: 1/8" = 1'-0" 6. COORDINATE DEMOLITION WORK w/ SCOPE OF NEW WORK AND PLANS. 7. SCHEDULE COORDINATION MEETING w/ LANDLORD TO IDENTIFY ITEMS TO BE TURNED OVER TO LANDLORD PRIOR TO STARTING DEMOLITION WORK. 8. CONTRACTOR TO REMOVE ALL WALLS OR PORTION OF WALL AS INDICATED IN ORDER TO ACHIEVE THE PROPOSED SCOPE OF WORK, INCLUDING DOORS, HEADER, WINDOWS, PEG-BOARD AND SOFFIT AS INDICATED ON PLAN. 9. SEE MECHANICAL PLANS FOR PLUMBING AND MECHANICAL NOTES. 10. PROVIDE NECESSARY CUTTING AND PATCHING OF ROOF AT ALL PENETRATIONS FOR PLUMBING, HVAC AND REFRIGERATION UNITS. IN ORDER TO PRESERVE THE ROOFING WARRANTY, THE CONTRACTOR THAT INSTALLED THE ROOF SHOULD PERFORM THE WORK. OTHERWISE, HAVE THE WORK PERFORMED BY A LICENSED ROOFING CONTRACTOR THAT IS APPROVED BY BOTH THE ROOFING MANUFACTURER AND THE LANDLORD. 11. REMOVE ALL DEBRIS FROM THE BUILDING AND ROOF AND DISPOSE OF IN ACCORDANCE WITH STATE AND LOCAL CODE OR ORDINANCES. C "COMPANY NAME" 20XX ALL RIGHTS RESERVED SEE ELECTRICAL PLANS FOR TERMINATION OF EXISTING WIRE & CONDUIT. 43 2. LANDLORD SHALL BREAK PORTION OF EXISTING CEILING TILE / GRID SYSTEM AS REQUIRED FOR NEW BRACING TO EXISTING STRUCTURE AT NEW DEMISING WALLS. 3. REMOVE AND DISPOSE OF EXISTING CMU WALL TO 8 INCHES BELOW FINISHED FLOOR FOR NEW MASONRY OPENING AND LINTEL. PATCH FLOOR FOR A SMOOTH TRANSITION. SEE 4 / S-1. 4. REMOVE EXISTING INTERIOR PARTITION. 5. NOT USED. 6. NOT USED. 7. NOT USED. 8. SAW CUT, REMOVE AND DISPOSE 3'-0" x 3'-0" OF EXISTING CONCRETE FLOOR SLAB AND EARTH FOR A NEW REFRIGERATION PIT. COORDINATE SIZE & LOCATIONS WITH REFRIGERATION, ELECTRICAL AND PLUMBING CONTRACTORS. PREPARE FOR NEW SLAB PATCH. 9. SAW CUT, REMOVE AND DISPOSE OF EXISTING CONCRETE FLOOR SLAB AND EARTH FOR NEW REFRIGERATION TRENCHES TO CONNECT TO NEW REFRIGERATION PITS. COORDINATE SIZE & LOCATIONS WITH REFRIGERATION, ELECTRICAL AND PLUMBING CONTRACTORS. PREPARE FOR NEW SLAB PATCH. SEE DETAIL 4/S-1 AND REFRIGERATION DRAWINGS. 10. NOT USED. 11. EXISTING DOOR AND FRAME TO BE REMOVED. 12. NOT USED. 13. NOT USED. 14. REMOVE ALL EXISTING SIGNAGE THROUGH OUT INCLUDING ANY INDICATION OF OF PREVIOUS SIGNAGE AT FRONT FASCIA. REMOVE FORMER TENANT'S CEILING MOUNTED SIGNAGE & DECOR, AWNINGS, CCTV, SOUND SYSTEM, SECURITY SYSTEM. REMOVE EXISTING WALL PAPER, BOARD FINISH, TRIM AND SHELVING SYSTEMS FROM PERIMETER SALES WALLS. REPAIR ALL HOLES, CRACKS OR DAMAGED WALL SURFACES AND PREPARE FOR RE-PAINTING. 15. NOT USED. 16. NOT USED. 17. NOT USED. 18. NOT USED. 19. NOT USED. 20. NOT USED. 21. NOT USED. 22. NOT USED. 23. LANDLORD SHALL REMOVE EXISTING DRYWALL PARTITIONS, BULK HEADS, DOORS AND ASSOCIATED ELECTRICAL AND PLUMBING TO ACCOMMODATE FIXTURE PLAN. PATCH FLOOR FOR A SMOOTH TRANSITION. 24. LANDLORD SHALL REMOVE EXISTING MOP SINK, ASSOCIATED WALLS & PLUMBING AND PATCH FLOOR AND WALLS. 25. NOT USED. 26. NOT USED. 27. NOT USED. 28. NOT USED. 29. NOT USED. 30. NOT USED. 31. NOT USED. 32. NOT USED. 33. LANDLORD SHALL REMOVE EXISTING WALL DECOR AND ATTACHMENTS. 34. LANDLORD SHALL REMOVE EXISTING CASE GUARDS AND RAILING IN THE SALES AREA AND BACK ROOM. 35. NOT USED. 36. NOT USED. 37. REMOVE AND DISPOSE SEGMENT OF EXISTING GUARDRAIL BETWEEN EXISTING FLOOR POSTS WHERE DEMISING WALL IS RUN. GRIND SMOOTH AT POST TO REMAIN. 38. LANDLORD SHALL REMOVE PORTION OF EXISTING BULKHEAD WALL AND SOFFIT TO 2-INCHES ABOVE COOLER HEIGHT. 39. REMOVE EXISTING TOILET PARTITIONS / DOORS AND ASSOCIATED ACCESSORIES. 40. REMOVE EXISTING TOILET FIXTURE AND ASSOCIATED PLUMBING. 41. REMOVE EXISTING WALL FINISHES AND ASSOCIATED ITEMS 42. REMOVE ONE ROW OF LIGHT FIXTURES RUNNING ALONG RIGHT DEMISING WALL. 43. REMOVE EXISTING HVAC SYSTEM AND DUCTWORK TO ACCOMMODATE NEW HVAC DESIGN AND DEMISING WALL. 44. LANDLORD SHALL REMOVE EXISTING DRYWALL PARTITIONS AND ASSOCIATED ELECTRICAL TO ACCOMMODATE FIXTURE PLAN. PATCH FLOOR FOR A SMOOTH TRANSITION. 45. SELECTIVE DEMOLITION OF EXISTING GYPSUM BOARD CEILING OR EXISTING SUSPENDED CEILING & GRID TO ACCOMMODATE NEW HVAC WORK. SEE MECHANICAL DRAWINGS. 37 1 3 M.O. 4'-0" 6'-11" TO 7'-4" AFF 3 2 8'-4" TO 7'-4" AFF 38 44 8 23 M.O. 3 6'-8" 23 9 TO 8'-0" AFF 23 8 8 44 1 23 11 39 40 14 33 34 45 4 45 39 4 11 40 3 REMOVE PORTION OF EXISTING WALL FROM FINISHED FLOOR TO DOOR HEAD HEIGHT. PATCH EXISTING WALL AND PROVIDE FINISHES TO MATCH. 23 23 1 VERIFY LANDLORD HAS REMOVED EXISTING QUARRY TILE AND SUBSTRATE THOUGHOUT EXISTING PREP AREA 38 11 VERIFY LANDLORD'S ABILITY TO REMOVE EXISTING MOP SINK & WALLS 45 39 23 40 4 G F E D C B A REAR NORTH RIGHT FRONT LEFT 1612 MILLS SQUARE 42 LANDLORD SHALL REMOVE & DISPOSE OF EXISTING FLOOR COVERINGS, MASTIC OR ADHESIVE, TILE SETTING BEDS AND REPAIR ANY DAMAGE EITHER CAUSED BY THIS REMOVAL OR EXISTING. REPAIR ANY DEFECTS IN THE FLOOR TO PLACE THE FLOOR IN GOOD CONDITION SMOOTH, LEVEL AND READY TO ACCOMMODATE A NEW VCT FLOOR COVERING .LANDLORD SHALL USE CEMENTITIOUS PATCHING MATERIAL AS OPPOSE TO LATEX PATCHING MATERIAL. CONTRACTOR SHALL PERFORM A VAPOR MOISTURE TEST PRIOR TO THE INSTALL OF ANY NEW VCT. JBS M.O. 2 1. DRAWN: 4'-0" M.O. 5'-0" 5'-8" 3'-4" 3 1 CERTIFICATION: KEYED NOTES ALEXANDER CITY, AL 5. 08/23/10 PROVIDE SHORING AND TEMPORARY SUPPORT AT NEW OPENINGS AND WHEN SETTING NEW LINTELS/ BEAMS,TO PREVENT SETTLING OF EXISTING ROOF AND WALL STRUCTURES. DATE: 4. PRELIMINARY NOT FOR BID OR CONSTRUCTION VERIFY LOAD BEARING CONDITIONS OF EXISTING WALLS PRIOR TO DEMOLITION AND NOTIFY ARCHITECT IMMEDIATELY WHERE BEARING WALLS OR UNANTICIPATED CONDITIONS ARE DISCOVERED CONTRARY TO PROPOSED PLANS. GAT 3. CHECKED: CONTRACTOR SHALL PROVIDE TRENCHING FOR ELECTRICAL, REFRIGERATION, PLUMBING AND CONDENSATE DRAIN FIELDS. TRENCHING INCLUDES SAW-CUTTING, EXCAVATING, BACK-FILLING, MOISTURE BARRIER AND CONCRETE WORK AS DETAILED. SEE STRUCTURAL DETAILS. DOWEL AND PATCH FLOOR SLAB AT EXISTING TRENCHES, REFRIGERATION ACCESS PITS AND AT OTHER AREAS W/ DAMAGED FLOOR SLAB. PROVIDE UNIT PRICES FOR SUCH CONDITIONS THAT MAY BE CONCEALED BY EXISTING FLOOR COVERING AT THE TIME OF BIDDING . DATE: 2. DESCRIPTION: PROVIDE DEMOLITION AND DISPOSAL OF EXISTING CONCRETE FLOOR SLAB FOR NEW REFRIGERATION, PLUMBING AND ELECTRICAL WORK. PROVIDE FLOOR SLAB PATCHING FOR A SMOOTH TRANSITION AT ALL NEW WORK. COORDINATE WITH REFRIGERATION, PLUMBING AND ELECTRICAL CONTRACTORS FOR QUANTITIES, LOCATIONS AND SIZES. REV. NUMBER: 1. BY: GENERAL NOTES STORE NUMBER PROJECT NUMBER 03510-01 SHEET TITLE DEMOLITION PLAN SHEET NUMBER A-0 1 DEMOLITION PLAN SCALE: 1/8" = 1'-0" 6C-1C NEW INTERIOR 6" METAL STUD WALL @16" O.C. W/ 5/8" TYPE "X" GYP. BD. ONE SIDE TO EXISTING CEILING HEIGHT - MATCH EXISTING FINISH AND DEPTH WERE APPLICABLE. 6C-2C NEW INTERIOR 6" METAL STUD WALL @16" O.C. W/ 5/8" TYPE "X" GYP. BD. EACH SIDE TO EXISTING CEILING HEIGHT - MATCH EXISTING FINISH AND DEPTH WERE APPLICABLE. 6H-2H NEW INTERIOR 6" METAL STUD WALL @16" O.C. W/ 5/8" TYPE "X" GYP. BD. EACH SIDE TO HEIGHT NOTED ON PLAN. E C D B 30'-8" 30'-0" 30'-0" 30'-0" 1'-0" 6. FLOORING TRANSITION - PROVIDE 1/8" DIAMOND PLATE TRANSITION FLUSH w/ TILE SURFACE. FASTEN TRANSITION PLATE w/ 1/4" DRIVE PINS. 7. NOT USED. 8. INSTALL MCCUE CORNER POST PROTECTORS (SUPPLIED BY SAVE-A-LOT). VERIFY QUANTITIES AND LOCATIONS. SEE DETAIL 9 / A-4. - TYPICAL 9. PROVIDE 4" x 4" WALL CURB. COORDINATE w/ SAVE-A-LOT PROJECT MANAGER. PAINT TO MATCH ADJACENT WALLS. SEE DETAIL 7 / A-4. 10. PROVIDE 4'-0" HIGH WAINSCOT OF 3/4" FIRE RETARDANT PLYWOOD (PAINT "PT-1") ON EXPOSED GYP. BD. WALLS IN BACK ROOM AREAS. 11. PROVIDE 6'-0" HT. STAINLESS STEEL CORNER GUARDS ON ALL DRYWALL CORNERS - TYPICAL. COORDINATE w/ SAVE-A-LOT PROJECT MANAGER. 12'-2" 12. PROVIDE "FRP-1" FINISH TO 8'-0" A.F.F. ON ENTIRE EXTENT OF GYP. BD. WALL BEHIND SINKS AS WELL AS RETURN OF WALL. 33'-1" 12'-2" 13. PROVIDE A 4'-0" x 8'-0" WAINSCOT OF "FRP-1" FINISH ON WALL IMMEDIATELY ADJACENT TO MOP SINK. 14. NOT USED. 14'-8" 15. PROVIDE CLOSURE PANELS AT ENDS OF REFRIGERATED CASES TO CONCEAL THE SPACE BETWEEN THE BACK OF THE CASE AND WALL. FABRICATE CLOSURE PANELS FROM "FRP-1" FINISH, LAMINATED OVER 3/4" PLYWOOD. SEE FINISH SCHEDULE KEY ON A-5 FOR ADDITIONAL INFORMATION. 16. PROVIDE CLOSURE PANELS AT COOLER / FREEZER TO WALL TO MATCH COOLER / FREEZER. PROVIDE NECESSARY VENTED CLOSURES WHERE COOLER BOXES ABUT WALLS OR ADJACENT COOLER BOXES TYPICAL. 17. INSTALL NEW REGISTER RAILING (SECURITY RAILING AND GATE - SUPPLIED BY SAVE-A-LOT). COORDINATE INSTALLATION w/ SAVE-A-LOT PROJECT MANAGER. 18. PROVIDE METAL TRANSITION STRIP SPECIFIED BY RESINOUS FLOORING MANUFACTURER. 19. CONTRACTOR SHALL PROVIDE 6" DIA. X 8'-0" LONG PVC PIPE FOR BALER WIRE. MOUNT ON WALL BEHIND BALER AT 48" A.F.F. VERIFY LOCATION W/ SAVE-A-LOT PROJECT MANAGER. 20. NOT USED. 21. CONTRACTOR SHALL SET AND ANCHOR CHECKOUT COUNTERS (SUPPLIED BY SAVE-A-LOT). INSTALL CHECKOUT COUNTER ACCESSORIES. VERIFY W/ SAVE-A-LOT PROJECT MANAGER. 22. CONTRACTOR SHALL ASSEMBLE AND POSITION BAGGING TABLES (SUPPLIED BY SAVE-A-LOT.) 23. FLOOR DRAIN. SEE PLUMBING DRAWINGS & DETAIL 17/A-4. 24. HUB DRAIN. SEE PLUMBING DRAWINGS. 25. GREASE INTERCEPTOR. SEE PLUMBING DRAWINGS. 26. RAMP AT FREEZER DOOR PROVIDED BY FREEZER MANUFACTURER. 27. PROVIDE TRENCHING. SEE DETAIL 4/S-1. 28. PROVIDE 3' X 3' METAL REFRIGERATION ACCESS PANEL. 29. PROVIDE CONTINUOUS 4" X 4" X 1/4" STEEL ANGLE CURB. SEE DETAIL 6/A-4. 30. NOT USED. 31. FUTURE REGISTER(S). SEE ELECTRICAL DRAWINGS. 32. NOT USED. 33. PROVIDE NEW CONCRETE STOOP AT EXIT DOOR. SEE DETAIL 6/S-1. 34. PROVIDE STEEL CHANNEL DOOR JAMBS AT RECEIVING DOOR. 35. EXISTING FIRE SPRINKLER RISER. 36. NOT USED . 37. NOT USED. 38. NOT USED. 39. NOT USED. 40. PROVIDE NEW LINTEL ABOVE DOOR - SEE STRUCTURAL. 41. NOT USED. 42. NOT USED. 43. NOT USED. 44. NOT USED. 45. NOT USED. 46. NOT USED. 47. PROVIDE FURRING AND 5/8" DRYWALL ON THE INTERIOR TO MATCH ADJACENT SURFACE. 48. NOT USED. 49. PROVIDE 8'-0" HIGH WAINSCOT OF 3/4" FIRE RETARDANT PLYWOOD (PAINT "PT-1") ON EXPOSED GYP. BD. WALLS IN PALLET STORAGE BACK ROOM AREAS. 50. FLOOR SINK. SEE PLUMBING DRAWINGS. 51. EXISTING FLOOR DRAIN TO REMAIN. 52. PROVIDE FRP PANELING AND MATCHING TRIM ON WALLS BEHIND THE ROLL-IN BREAD RACKS, 16'-0" WIDE x 6'-4" HIGH. 53. PROVIDE FRP PANELING AND MATCHING TRIM ON WALLS BEHIND THE DRY PRODUCE BINS, 75'-0" WIDE x 6'-2" HIGH. 54. RECESSED ELECTRICAL PANEL. SEE SEE ELECTRICAL DRAWINGS. 55. PROVIDE CARPET TILE AT FRONT ENTRY DOOR. SEE CPT-1 ON A-5. 56. ALL PERIMETER WALLS IN SALES AREA TO HAVE DRYWALL SURFACE SUITABLE FOR PAINTING. PATCH OR REPLACE EXISTING DRYWALL AS REQUIRED. 57. EXISTING TRANSFORMER. 58. REFURBISH THE EXISTING AUTOMATIC DOORS. 59. NOT USED. 60. PROVIDE NEW LINTEL ABOVE OPENING - SEE STRUCTURAL. 61. EXISTING GAS METER. 62. VERIFY ABILITY TO ACHIEVE 1-HOUR, UL RATED DEMISING WALL. SHOULD 1 HOUR SEPARATION NOT BE ACHIEVABLE GIVEN THE EXISTING CONDITIONS AT THE LOCATION INDICATED, NOTIFY THE PROJECT MANAGER TO IDENTIFY LOCATION AND CONFIGURATION OF DEMISING WALL NEAREST TO THE LOCATION SHOWN THAT IS AGREEABLE TO THE LANDLORD AND FIRE MARSHAL. 63. PROVIDE FRP PANELING AND MATCHING TRIM ON FRONT WALL, BENEATH THE WINDOW SILLS. 64. PROVIDE FRP PANELING AND MATCHING TRIM OVER ALL SALES AREA DRYWALL SURFACES NOT COVER BY REFRIGERATION CASES. 65. NOT USED. 66. PROVIDE NEW STEEL STAIR. SEE DETAIL 6 OR 7/S-1 67. PROVIDE NEW, MOISTURE RESISTANT GYP BOARD WALL PATCHES TYPICAL FOR REMOVED FIXTURES. PATCH & LEVEL FLOOR AT REMOVED TOILET FIXTURE FOR NEW FLOOR FINISH. 134'-11" 1 62 9 49 28 4'-0" 16 4H-1H BOTTOM OF CEILING 15 6'-11" 60 29 84'-8" M.O. 1'-4" 4'-0" 24 8 4H-1H BOTTOM OF CEILING 4H-2H 5'-6" A.F.F. 23 63 11 60 16 VESTIBULE 24 100 2 55 MEAT PREP 4H-2H 2 TO TOP OF COOLER 108 100A 31 24 UP 53 8 16 18 9 53 4 THUS 50 109 24 29 11 8 8'-0" MEAT COOLER 8 21'-3" 11 31'-8" 9 117 4" 4'-0" 60 6'-0" 117A M.O. BACK ROOM 'B' 40 5'-0" 19 9'-0" 1 1 4'-0" 33 SIM 28 15 4'-0" 1 15 6" 1 25 16 18 60 27 9 "ES-1" 8 101 4 THUS PRODUCE COOLER 110 SALES AREA 10 9 56 21 A-4 22 64 24 113 4'-0" 58 43'-0" FREEZER 9 19 21 22 16 90'-1" 26 17 9 9 "CS-1" 51 29 3'-8" 4'-6" 2 THUS 8 SAFE 11 102 8 29 6C-2C 103A 4H-2H 5'-6" A.F.F. 6'-0" 57 105 51 9 RECEIVING WOMEN 107 115 11 67 1'-0" 13 29 5 STORAGE 16 118 14'-1" 1'-0" 10'-0" 24 8 A-3 34 20'-1" 8" 11'-1" 3'-11" 104A 24 24 BOTTOM OF 4H-1H CEILING 16 4 116 54 103 47 24 A-4 DAIRY COOLER 52 4C-2C 3 BREAK ROOM 104 4'-0" 20'-0" CORRIDOR 'A' 3 OFFICE 2 116A 3 2 THUS "ES-1" 29 10 3 4 67 117 9 4C-2C 58'-11" 11 47 4 1'-0" BACK ROOM 'B' 16 21 TO TOP OF COOLER 4H-2H 2 25'-10" 35 9 A-3 13'-6" 119 10 24 114 8 1 6'-6" 11 6'-6" MEN "CS-1" RECEIVING OFFICE 50 114A 4 THUS 22 29 11'-4" 9'-6" 112 "ES-1" 61 67 4" A-4 3'-6" PRODUCE PREP AREA 3'-1" 4'-0" 12 4C-1C 22 4'-4" A.F.F. 4H-2H 1'-2" 10 4'-10" 9 9 111 21 6'-0" 10 6 8 8 7'-5" A-4 16 111A 6'-10" 13 24 "VCT-1" 9 "CS-1" 15 BACK ROOM 'A' 28 4'-4" 2'-6" 15'-6" 1'-0" 137'-5" BY: PROVIDE MOP RACK AT THE MOP SINK. 149'-7" 16'-0" 66 5. A 174'-2" 15'-0" PROVIDE A 36" X 36" X 1/4" ONE WAY MIRRORED GLASS WINDOW, PROVIDE TEMPERED GLASS WHEN WINDOW IS ADJACENT TO DOOR AS REQUIRED BY CODE. LOCATED IN NEW OFFICE. SEE A-3 C "COMPANY NAME" 20XX ALL RIGHTS RESERVED NEW INTERIOR 3 5/8" METAL STUD WALL @16" O.C. W/ 5/8" TYPE "X" GYP. BD. EACH SIDE TO HEIGHT NOTED ON PLAN. 20'-9" 4. 1'-0" 189'-3" RIGHT NORTH REAR STORE NUMBER FRONT PROJECT NUMBER 03510-01 LEFT SHEET TITLE FLOOR PLAN SHEET NUMBER A-1 1 FLOOR PLAN SCALE: 1/8" = 1'-0" ALEXANDER CITY, AL 4H-2H 20'-5" PROVIDE SOUND INSULATION WITHIN WALL ( 4" FOR 4" STUD WALL OR 6" FOR 6" STUD WALL). 08/23/10 4H-1H NEW INTERIOR 3 5/8" METAL STUD WALL @16" O.C. W/ 5/8" TYPE "X" GYP. BD. ONE SIDE TO HEIGHT NOTED ON PLAN. F 3. DATE: NEW INTERIOR 3 5/8" METAL STUD FRAMING @ 16" O.C. W/ 5/8" TYPE "X" GYP. BD. EACH SIDE TO EXISTING CEILING HEIGHT - MATCH EXISTING FINISH AND DEPTH WHERE APPLICABLE. DATE: 4C-2C 1612 MILLS SQUARE G NEW INTERIOR 3 5/8" METAL STUD FRAMING @ 16" O.C. w/ 5/8" TYPE "X" GYP. BD. ONE SIDE TO EXISTING CEILING HEIGHT - MATCH EXISTING FINISH AND DEPTH WERE APPLICABLE. PROVIDE FIRE RETARDANT WOOD BLOCKING AS REQUIRED FOR PLUMBING FIXTURES AND ACCESSORIES. PRELIMINARY NOT FOR BID OR CONSTRUCTION GENERAL CONTRACTOR SHALL PROVIDE QUANTITY AND TYPE OF FIRE EXTINGUISHERS AS DIRECTED BY FIRE MARSHAL. MINIMUM OF 5 REQUIRED. 4C-1C GAT FIRE EXTINGUISHER UL RATING 2A-10B:C LARSEN'S MANUFACTURING OR EQUAL MODEL #MP5 (STANDARD BRACKET) PROVIDE A NEW WALL BETWEEN THE SALES AREA AND THE BACK ROOM. WALL CONSTRUCTION TO BE OF 6" METAL STUDS AT 16" O.C. AND COVERED WITH 5/8", TYPE X GYPSUM WALLBOARD. RUN THE WALL OVER THE TOP OF THE COOLER THAT MAY EXTEND INTO THE SALES AREA AND EXTEND TO THE BOTTOM OF THE ROOF DECK. SEE DETAIL 1/A-4. CHECKED: LIFE SAFETY LEGEND 2. DESCRIPTION: NEW WALL, CONSTRUCTION PER WALL TAG NEW FREEZER / COOLER WALL PANEL - N.I.C. 101A LANDLORD SHALL PROVIDE NEW DEMISING WALL W/ SOUND INSULATION FROM FLOOR TO ROOF DECK BETWEEN THE FRONT AND REAR WALLS OF THE BUILDING. WALL CONSTRUCTION IS TO COMPLY WITH LOCAL CODES. IF REQUIRED BY CODE PROVIDE FIRE SEALANT AND SYSTEM SPECIFIED IN UL DETAILS 22 & 23 / A-4. DIMENSIONS ARE NOMINAL FROM FACE OF STUD AT NEW WALL CONSTRUCTION TO FACE OF EXISTING WALL FINISH OF EXISTING WALLS. 2. SEE A-5 DOOR SCHEDULE, FOR DOOR INFORMATION. 3. SEE A-5 ROOM FINISH SCHEDULE, FOR ROOM FINISHES. 4. ALL PERIMETER WALLS IN SALES AREA ARE TO HAVE SURFACES SUITABLE FOR PAINTING. CONTRACTOR SHALL PATCH OR REPLACE EXISTING DRYWALL AS REQUIRED. 5. CONTRACTOR SHALL PAINT ALL EXPOSED DRYWALL SURFACES AT PERIMETER OF SALES AREA. 6. INSTALL "BOSTON BUMPER" RUB RAIL - FURNISHED BY SAVE-A-LOT ALONG OFFICE WALLS AND WHERE CART DAMAGE MAY OCCUR. VERIFY LOCATIONS WITH SAVE-A-LOT PROJECT MANAGER PRIOR TO INSTALLATION. 7. CONTRACTOR SHALL PROVIDE TRENCHING FOR ELECTRICAL, REFRIGERATION, PLUMBING AND CONDENSATE DRAIN FIELDS. TRENCHING INCLUDES SAW-CUTTING, EXCAVATING, BACK-FILLING, MOISTURE BARRIER AND CONCRETE WORK. AS DETAILED, SEE STRUCTURAL DETAILS. DOWEL AND PATCH FLOOR SLAB AT EXISTING TRENCHES, WALKER DUCT, REFRIGERATION ACCESS PITS AND AT OTHER AREAS W/ DAMAGED FLOOR SLAB. PROVIDE UNIT PRICES FOR SUCH CONDITIONS THAT MAY BE CONCEALED BY EXISTING FLOOR COVERING AT THE TIME OF BIDDING . 8. CONTRACTOR SHALL TOUCH-UP EXTERIOR PAINT AT NEW AND CLOSED OPENINGS CONSISTENT w/ ADJACENT SURFACES. 9. CONTRACTOR SHALL SET AND ANCHOR SPOT MERCHANDISERS (SUPPLIED BY SAVE-A-LOT) PER FIXTURE LAYOUT. 10. CONTRACTOR SHALL INSTALL CART CORRALS (SUPPLIED BY SAVE-A-LOT). 11. CONTRACTOR SHALL REPAIR ALL DAMAGE CAUSED BY EQUIPMENT INSTALLATION, REMOVAL OR RELOCATION. REV. NUMBER: NEW FIRE RATED (1-HR) DEMISING WALL. NEW DOOR (SWING SHOWN AT 90 DEGREE). SEE DOOR SCHEDULE 1. 1. CERTIFICATION: EXISTING WALL TO REMAIN. EXISTING DOOR TO REMAIN. (SWING SHOWN AT 45 DEGREE). KEYED NOTES GENERAL NOTES JBS WALL LEGEND DRAWN: DOOR LEGEND CONTRACTOR TO COORDINATE ALL CEILING WORK INVOLVED WITH INSTALLING NEW CEILINGS AT REQUIRED HEIGHT. THIS WORK SHALL INCLUDE, BUT IS NOT LIMITED TOO, HVAC SYSTEM REWORK, ELECTRICAL REWORK, ETC. CONTRACTOR TO NOTIFY ARCHITECT OF ANY CONFLICTS IMMEDIATELY. CONTRACTOR TO COORDINATE NEW WORK REQUIREMENTS w/ ALL DISCIPLINES WITHIN THIS SET OF DRAWINGS. CONTRACTOR TO INVESTIGATE EXISTING CONDITIONS THOROUGHLY AND IDENTIFY CONFLICTS, IF ANY, AS EARLY AS POSSIBLE DURING CONSTRUCTION IN ORDER TO RESOLVE CONFLICTS AS QUICKLY AS POSSIBLE. C "COMPANY NAME" 20XX ALL RIGHTS RESERVED 2. DATE: FIELD VERIFY ALL WALL LOCATIONS WITH RESPECT TO CEILING & LIGHT LAYOUT AND NOTIFY ARCHITECT OF DISCREPANCIES. CONTRACTOR HAS SOLE RESPONSIBILITY OF FIELD VERIFYING EXTENT OF PREP WORK REQUIRED TO COMPLETE INTENDED SCOPE OF WORK. F E D C B CLEAN EXISTING CEILING TILE, CEILING GRID. 2. NOT USED. 3. PROVIDE NEW ACP-1 AND GRID AT 10'-0" A.F.F. PROVIDE 6" FIBERGLASS BATT INSULATION ABOVE CEILING TILES. REFER TO ROOM FINISH SCHEDULE ON A-5. 4. PROVIDE NEW ACP-2 AND GRID AS HIGH AS POSSIBLE UNDER EXISTING MEZZANINE ABOVE PRODUCE AREA SINK WORK AREA. VERIFY EXTENT REQUIRED WITH DEPARTMENT OF AGRICULTURE. 5. PRE-MANUFACTURED COOLER / FREEZERS. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION ON LIGHT FIXTURES. 6. CLEAN EXISTING CEILING TILE, CEILING GRID AND DIFFUSERS TO REMAIN ABOVE COOLERS / FREEZERS. 7. PROVIDE AND INSTALL NEW GYP. BD. CEILING AT 8'-0" A.F.F. PROVIDE 6" FIBERGLASS BATT INSULATION ABOVE CEILING. REFER TO ROOM FINISH SCHEDULE ON A-5. 8. NOT USED. 9. NOT USED. CERTIFICATION: G 1. PRELIMINARY NOT FOR BID OR CONSTRUCTION KEYED NOTES REV. NUMBER: DESCRIPTION: 1. BY: GENERAL NOTES A CEILING LEGEND BACK ROOM "B" 117 OPEN TO STRUCTURE 1 1 EXISTING GRID @ 13'-0" A.F.F. EXISTING SUSPENDED CEILING SYSTEM VESTIBULE EXISTING SUSPENDED CEILING SYSTEM TO REMAIN ABOVE NEW CEILING 100 1 EXISTING GRID @ 10'-0" A.F.F. 2 NEW LIGHT EXISTING LIGHT TO REMAIN VERIFY WITH PM IF REPAIR TO BACK ROOM CEILING & GRID IS REQUIRED 1 CHECKED: 108 5 6 EXISTING GRID @ 13'-0" A.F.F. GAT NEW GYPSUM BOARD CEILING MEAT PREP BLM 6 DRAWN: 109 5 DATE: MEAT COOLER 08/23/10 NEW SUSPENDED CEILING SYSTEM EXISTING LIGHT TO BE RELOCATED OR REMOVED NL NON-SWITCHED NIGHT LIGHT EXISTING GRID @ 13'-0" A.F.F. 2'X4' FLUORESCENT LIGHT RECESSED CHANNEL PRODUCE COOLER 110 5 113 5 WALL PACK LIGHT SALES AREA DOCK LIGHT 101 1 EXISTING GRID @ 13'-0" A.F.F. 6 EMERGENCY LIGHT WITH BATTERY PACK EXIT LIGHT CORRIDOR "A" 117 OPEN TO STRUCTURE 1 SUPPLY AIR/DIFFUSER BACK ROOM "A" 111 1 EXISTING GRID @ 13'-0" A.F.F. RETURN, EXHAUST, OR TRANSFER GRILLE PRODUCE PREP AREA SUPPLY AIR 4 112 "ACP-2" @ SEE KEY NOTE 3 20'-0" RECEIVING OFFICE 119 OPEN TO STRUCTURE 116 OPEN TO STRUCTURE 7 114 NEW GYP. BD. CLG. @ 8'-0" A.F.F. EXHAUST AIR SUPPLY REGISTER (SIDEWALL) OFFICE 103 3 "ACP-1" @ 10'-0" A.F.F. MEN RECEIVING RETURN GRILLE (SIDEWALL) STORE NUMBER DAIRY COOLER 6'-0" 107 5 6 EXISTING GRID @ 13'-0" A.F.F. WOMEN 7 115 NEW GYP. BD. CLG. @ 8'-0" A.F.F. EXHAUST GRILE (SIDEWALL) PROJECT NUMBER BREAK ROOM 03510-01 104 3 "ACP-1" @ 10'-0" A.F.F. SHEET TITLE 4 REFLECTED CEILING PLAN STORAGE 118 EXISTING GYP. BD. CLG. @ 9'-0" A.F.F. NORTH RIGHT REAR FRONT LEFT 1 1612 MILLS SQUARE BACK ROOM "B" 105 REPAIR EXIST'G. GYP. BD.CLG. @ 8'-0" A.F.F. AT MECH WORK REFLECTED CEILING PLAN ALEXANDER CITY, AL FREEZER SCALE: 1/8" = 1'-0" SHEET NUMBER A-2 C "COMPANY NAME" 20XX ALL RIGHTS RESERVED DATE: DESCRIPTION: PRELIMINARY NOT FOR BID OR CONSTRUCTION SAVE-A-LOT HAS A STRATEGIC ACCOUNT AGREEMENT WITH SHERWIN WILLIAMS PAINT COMPANY AND BENJAMIN MOORE PAINTS, WHICH SECURES FAVORED PRICING FOR MATERIALS USED ON SAVE-A-LOT PROJECTS. ALL PRODUCTS SPECIFIED - IN BOTH COLOR AND NAME - ARE OF MANUFACTURE FROM THE SHERWIN WILLIAMS PAINT COMPANY AND BENJAMIN MOORE PAINTS. FOR ANY CONCERNS OR QUESTIONS REGARDING THESE SPECIFICATIONS, PLEASE CONTACT SHERWIN WILLIAMS ARCHITECTURAL ACCOUNT EXECUTIVE BRIAN BENSON AT (303) 794-8472 OR BENJAMIN MOORE NATIONAL ACCOUNT DEPARTMENT AT (877) 626-5676 (SAVE-A-LOT IS NATIONAL ACCOUNT NA - 060.) 2. SPECIFIED PAINT PRIME AND FINISH COATS ARE IN ADDITION TO SHOP PRIMING AND SURFACE TREATMENTS PROVIDED BY OTHER TRADES PRIOR TO PAINTING. ALL SURFACE PREPARATION MUST BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S PRODUCT DATA LITERATURE AND LABEL INSTRUCTIONS. ALL SURFACES SHOULD BE CLEAN, DRY AND FREE OF ANY DIRT OR ADDITIONAL FOREIGN CONTAMINATES. 3. PROVIDE PATCH, REPAIR & PAINT TO EXISTING WALL AND COLUMNS AS SHOWN. PRIME AND PAINT AS NOTED. (INSERT APPLICABLE PAINT INFORMATION FROM EXTERIOR RENDERING SHEET HERE) 4. NEW 12" HIGH RED METAL STRIPE PAINT (P-4) TO BE SHERWIN WILLIAMS #SW4081 "SAFETY RED" N.I.C., TENANT TO PROVIDE UNDER SEPARATE CONTRACT. 5. NEW EXTERIOR SIGNS, N.I.C., TENANT TO PROVIDE UNDER SEPARATE CONTRACT, HOWEVER G.C. TO PROVIDE POWER AND COORDINATE WITH SIGN INSTALLER. 6. CENTER SAVE-A-LOT SIGNAGE ON SAVE-A-LOT LEASED SPACE UPPER WALL FACADE AS SHOWN. 7. SIGNAGE TO BE 6' HIGH "SAVE A LOT" LETTER SET WITH 30" "FOOD STORES" LETTER SET. THE BASE LINE OF "FOOD STORES" TO BE 6'-0" BELOW THE BASE LINE OF "SAVE". 8. BOTTOM OF RED STRIPE TO ALIGN WITH THE BASE LINE OF "FOOD STORES". 9. OVER ALL SIGNAGE AREA IS TO BE APPROX. 377 S.F. 10. TOUCH UP EXTERIOR PAINT AT NEW AND CLOSED OPENINGS CONSISTENT WITH ADJACENT SURFACES. REV. NUMBER: 1. BY: GENERAL NOTES - EXTERIOR ELEV's EXTERIOR PAINT SPECS EXTERIOR MASONRY: COLOR AS NOTED 1/A-3 USE AT CMU, CINDER BLOCK, BRICK: TWO FINISH COATS OVER AN EXISTING FINISH OR PRIMER. PRIMER (IF NEEDED): SHERWIN-WILLIAMS LOXON BLOCK SURFACER, A24W200 (APPLIED @ 16 MILS WET; 8 MILS DRY), OR BENJAMIN MOORE LATEX BLOCK FILLER, PRODUCT M88 (APPLIED @ 15.8 MILS WET; 6.0-8.0 MILS DRY. 1ST & 2ND COATS: SHERWIN-WILLIAMS A-100 EXTERIOR LATEX SATIN, A82 SERIES (APPLIED @ 4 MILS WET; 1.3 MILS DRY), OR BENJAMIN MOORE - SUPER SPEC LOW LUSTRE HOUSE PAINT PRODUCT N185 (APPLIED @ 3.3 - 4.5 MILS WET: 1.1 - 1.5 MILS DRY) EXTERIOR METAL SIDING: COLOR AS NOTED 1/A-3 PRIMED, PRE-PAINTED TWO FINISH COATS OVER EXISTING FINISH OR PRIMER. ALWAYS CHECK FOR COMPATIBILITY of PREVIOUS PAINTED SURFACE WITH NEW COATING BY APPLYING A TEST PATCH OF 2-3 SQUARE FEET. ALLOW TO DRY AT LEAST 1 WEEK BEFORE DOING AN ADHESION TEST. 1ST & 2ND COATS: SHERWIN-WILLIAMS BOND-PLEX WATER BASED ACRYLIC COATING, B71-200 SERIES (APPLIED @ 4.8 MILS WET; 2 MILS DRY), OR BENJAMIN MOORE - D.T.C. ACRYLIC SEMI-GLOSS, PRODUCT M29 (APPLIED @ 3.8 - 6.2 MILS WET: 1.5 - 2.5 MILS DRY) FURNITURE & EQUIP. SCHEDULE "PT-1" KEY NOT USED. PROVIDE ALL NEW SIGNS, DECALS, SYMBOLS AND ANY ADDITIONAL REQUIREMENTS FOR DISABLED ACCESSIBILITY AS DESIGNATED BY LOCAL CODES FOR EXISTING RESTROOMS. PROVIDE NECESSARY FIRE TREATED WOOD BLOCKING FOR TOILET ACCESSORIES. NOT USED. NOT USED. NOT USED. NOT USED. REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATION. ALSO ROOM FINISH SCHEDULE. ELEC. PANEL LIGHT GRAY AMCON 536 SNOWDRIFT OR EQUIVALENT COMPUTER DESK (NIC) 30" x ROOM WIDTH C-2 DARK GRAY AMCON 542 AGGAZIZ OR EQUIVALENT C 3-SHELF STORAGE CABINET (NIC) 18" x 36" D-1 WARM BEIGE EFIS DRYVIT 463A STEPHS MOOD F 4-DRAWER LEGAL FILE CABINET (NIC) 18" x 36" D-2 GREY WHITE EFIS DRYVIT 103 NATURL WHITE HARDIE BOARD OR EQUIVALENT G 2-DRAWER FILE CABINET (NIC) 18" x 36" D-3 DARK BROWN EFIS DRYVIT 142 SPECTRUM BROWN DESK CHAIR (NIC) M-1 SILVER GRAY UNA-CLAD SANDSTONE OR EQUIVALENT SAFE (NIC) P-1 WARM BEIGE SHERWIN WILLIAMS SW6371 VANILLIN DE DEPOSIT (NIC) P-2 GRAY WHITE SHERWIN WILLIAMS SW7029 AGREEABLE GRAY CH CHANGE (NIC) P-3 DARK BROWN SHERWIN WILLIAMS SW7031 MEGA GREIGE P-4 RED SHERWIN WILLIAMS SW4081 SAFETY RED RESTROOM FIXTURE SCHEDULE GRAB BAR PF PLUMBING FIXTURE CT CHANGING TABLE HD HAND DRYER MR MIRROR NOT USED SD SOAP DISPENSER NOT USED TT TOILET TISSUE DISPENSER NOT USED ND NAPKIN DISPOSAL NOT USED TP TOILET PARTITIONS P-5 SILVER GRAY SHERWIN WILLIAMS SW4026 SLATE GRAY LOCKER NOT USED P-6 GRAY SHERWIN WILLIAMS SW7030 ANEW GRAY CR COAT RACK NOT USED MD MIO DESK NOT USED LC LOWER CABINET WITH SINK NOT USED 1. UC UPPER CABINET NOT USED MW MICROWAVE NOT USED RF REFRIGERATOR NOT USED 2. 3. 4. 5. 2'-10" SCALE: 1/4"=1'-0" "PT-3" WINDOW FRAME "PT-1" REMARKS 3'-0" SIM. NOT USED 14 A-4 GENERAL NOTES - OFFICE 1'-0" SEE ELECTRICAL DRAWINGS PROVIDE NECESSARY FIRE TREATED WOOD BLOCKING FOR DESK, TIME-CLOCK AND ACCESSORIES. COORDINATE WITH SAVE-A-LOT PROJECT MANAGER. CONTRACTOR IS RESPONSIBLE FOR INSTALLATION OF ANY / ALL TENANT FURNISHED ITEMS U.N.O. REFER TO FLOOR PLAN SHEET AND WALL LEGEND FOR PARTITION TYPES. REFER TO DOOR AND FINISH SCHEDULES FOR ADDITIONAL INFORMATION. DESK AND COMPUTER DESK LAMINATES TO BE A LIGHT NEUTRAL BOX STORE STOCK LAMINATE (ALMOND, WHITE, BEIGE, ETC.). DESK TO BE SUPPORTED WITH CONTINUOUS 2X4 HORIZONTALLY @ 30 1/2"A.F.F. ON THE WALL AS THE MAIN SUPPORT AND 2X4 KICKER SUPPORTS AT 45 DEGREE ANGLE, 32" O.C. 14 A-4 2'-0" CD D PROVIDE 12" x WIDTH OF ROOM x 3/4" HINGED LAMINATED SHELF AT TOP OF WALL. VERIFY LOCATION OF SHELF w/ SAL PROJECT MANAGER. 6" 7"-9" TOILET PAPER DISPENSER SCALE: 1/4"=1'-0" DE CONTRACTOR SHALL PROVIDE HEAVY-DUTY VINYL OR EPOXY COATED WIRE SHELVING 19" MIN. 33"-36" PLASTIC LAMINATED WALL BRACE - TYP. OFFICE ELEVATION 2 2" MIN. 18" GRAB BARS 33"-36" 3" MIN 6"MAX 42" 12" 17"-19" 12" 18" 36" PLASTIC LAMINATED WALL MOUNTED, BUILT-IN COUNTER DRAWN: VERTICAL GRAB BAR ONLY IF REQUIRED BY LOCAL AND OR STATE REGULATIONS 08/23/10 GB NOT USED DATE: ITEM STACKABLE CHAIR L 30" X 72" GAT KEY NOT USED SC OFFICE ELEVATION 1 TABLE CHECKED: 15" MIN. 38" WALL ELEVATION C-1 2'-10" MAX. SANITARY NAPKIN DISPOSAL HAND DRYER ADDITIONAL HAND DRYERS MOUNT AT 44" A.F.F. TO BOTTOM OF UNIT WATER COOLER "PT-3" DOOR AND FRAME "VB-1" 3'-0" DRINKING FOUNTAINS 24" x 48" T 3'-8" MIN. 30" x 48" CLEAR FLOOR SPACE @ DRINKING FOUNTAIN 3'-0" 4'-0" MIN. 15" 15" 2'-6" 6" DESK (NIC) S CD NOTE: ACCESSIBLE WATER COOLER SPOUTS SHALL BE LOCATED NOT MORE THAN 36" ABOVE FINISHED FLOOR AND LOCATED SO THE FLOW OF WATER IS WITHIN 3" OF THE FRONT OF THE UNIT AND SHALL DIRECT A WATER FLOW NOT LESS THAN 4 INCHES HIGH. CONTROLS SHALL BE LOCATED NOT MORE THAN 6" FROM THE FRONT OF THE UNIT. DRYVIT / FINISH DC 2'-6" URINAL DRINKING FOUNTAIN W/MIN. 27" HEIGHT TO BOTTOM OF APRON ON WHEELCHAIR ACCESSIBLE FOUNTAIN. SPOUT TO BE NO HIGHER THAN 36" A.F.F. COLOR CD SALES AREA 17"-19" NOMINAL SIZE D 60" MIN. WATER CLOSETS ITEM EXTERIOR PAINT SCHEDULE BLM 3'-8" 3. 4. 5. 6. 7. 8. SCALE: N.T.S. 10'-0" 4" MAX. NOTE: MOUNT SANITARY NAPKIN DISPENSER 40" MAXIMUM FROM FINISHED FLOOR TO THE HIGHEST OPERATING CONTROL. MOUNT DIAPER CHANGING TABLE 34 INCHES FROM FINISHED FLOOR TO BOTTOM OF UNIT. MIN. CLR. MAX. 32" MIN. 2'-6" 17" 42" MIN. 1. 2. 42" MIN. 48" MIN. CLR. 18" 60" MIN. PARTIAL ELEVATION - PROPOSED NEW SIGNAGE & CANOPY WORK GENERAL NOTES - RESTROOM 1 EXTERIOR WOOD: COLOR AS NOTED 1/A-3 USE AT PRIMED, RAW AND PREVIOUSLY PAINTED - TWO FINISH COATS OVER EXISTING FINISH OR PRIMER . PRIMER (IF NEEDED): SHERWIN-WILLIAMSA-100 EXTERIOR LATEX WOOD PRIMER B42W41 (APPLIED @ 4 MILS WET; 2.3 MILS DRY), OR BENJAMIN MOORE FRESH START ACRYLIC PRIME, PRODUCT 023 (APPLIED @ 3.8 MILS WET; 1.1 MILS DRY. 1ST & 2ND COATS: SHERWIN-WILLIAMS A-100 EXTERIOR LATEX SATIN, A82 SERIES (APPLIED @ 4 MILS WET; 1.3 MILS DRY), OR BENJAMIN MOORE - SUPER SPEC LOW LUSTRE HOUSE PAINT PRODUCT N185 (APPLIED @ 3.3 - 4.5 MILS WET: 1.1 - 1.5 MILS DRY) CERTIFICATION: EXTERIOR SHEET METAL: COLOR AS NOTED 1/A-3 KYLAR, PRE-PAINED TWO FINISH COATS OVER EXISTING FINISH OR PRIMER. 1ST & 2ND COATS: SHERWIN-WILLIAMS BOND-PLEX WATER BASED ACRYLIC COATING, B71-200 SERIES (APPLIED @ 4.8 MILS WET; 2 MILS DRY) CH S "PT-1" SAFE 102 MIRROR LAVATORIES NOTE: MOUNT SOAP DISPENSERS AT 40" MAX TO BOTTOM OF DISPENSER. 114 17" MIN CD D 2 1 OFFICE "VB-1" CT 3 G 3 A-3 G D F 3 F 4 103 F OFFICE ELEVATION C SCALE: 1/4"=1'-0" ADA NOTES: (*PROVIDE AND INSTALL TOILET ROOMS AND ALL TOILET FIXTURES PER PREVAILING CODES*) "PT-1" C C CONTRACTOR TO PROVIDE 12" WIDE HEAVY-DUTY VINYL OR EPOXY COATED WIRE SHELVING. VERIFY LOCATION w/ SAL PROJECT MANAGER HD INSIDE CLEAR DIMENSIONS SHOWN ARE AS REQUIRED TO MEET HANDICAPPED CLEARANCE CRITERIA. COORDINATE STUD/ SUBSTRATE DIMENSIONS W/ WALL TYPES SHOWN ON FLOOR PLAN. STORE NUMBER BREAK ROOM WOMEN PROVIDE FRT WOOD BLOCKING IN WALL BEHIND ALL WALL MOUNTED TOILET ACCESSORIES & EQUIPMENT. 115 4.26.2 GRAB BARS. OUTSIDE DIAMETER - MIN. 1 1/4", MAX. 1 1/2", SPACE BETWEEN WALL AND GRAB BAR - 1 1/2". 4.27.4 OPERATION. CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5 LB (22.2 N). SCALE: 1/4" = 1'-0" 03510-01 SHEET TITLE TP VERIFY 2'-9" 4 PROJECT NUMBER 1'-0" C GB C ENLARGED FLOOR PLANS AND EXT. ELEVATION C 5'-8" 4.19.5 FAUCETS. FAUCETS SHALL COMPLY WITH 4.27.4. LEVER-OPERATED PUSH- TYPE, AND ELECTRONICALLY CONTROLLED MECHANISMS ARE EXAMPLES OF ACCEPTABLE DESIGNS. SELF-CLOSING VALVES ARE ALLOWED IF THE FAUCET REMAINS OPEN FOR AT LEAST 10 SECONDS. VERIFY (5'-0" MIN CLEAR REQ'D) 4.19.4 EXPOSED PIPES AND SURFACES. HOT WATER AND DRAIN PIPES UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL BE NO SHARP OR ABRASIVES SURFACES UNDER LAVATORIES. 2'-9" 4.16.5 FLUSH CONTROLS. FLUSH CONTROLS SHALL BE HAND OPERATED OR AUTOMATIC AND SHALL COMPLY WITH 4.27.4. CONTROLS FOR FLUSH VALVES SHALL BE MOUNTED ON THE WIDE SIDE OF TOILET AREAS NO MORE THAN 44" (1120mm) ABOVE THE FLOOR. VERIFY 104 THE RESTROOM LAYOUT IS BASED ON AND COMPLIES W/ THE "AMERICAN WITH DISABILITIES ACT" LATEST REGULATIONS. PLEASE NOTE THE FOLLOWING SECTIONS: ACCESSIBLE TOILET ELEV. CD TP GB 5 DC SHELF HT. CLEARANCE 6'-0" 5'-3 1/2" MEN 6"MIN TOE 2'-10" 27"MIN 8" MIN 2'-6" BRACKET HT. DC HD 29"MIN 48" MIN. 34" MAX 19" MAX. A-4 CL 27" MIN. 29" MIN. 34" MAX. CLEAR FLOOR SPACE 40" MAX. 15" 15" 30" MIN. MIRROR G.C. TO PROVIDE 3'-4" x 12" x 3/4" LAMINATED SHELF. CUT 2x4 NOTCH AT THE REAR AND CENTER TO ACCOMMODATE WIRING FOR FRAME RELAY SYSTEM. VERIFY LOCATION OF SHELF w/ SAL PROJECT MANAGER. CONTRACTOR TO VERIFY SHELF HAS PROPER SUPPORT FOR FRAME RELAY SYSTEM 1612 MILLS SQUARE 5 ALEXANDER CITY, AL 1x4 TRIM WATER CLOSETS CT "VB-1" SHEET NUMBER 4 ENLARGED RESTROOM PLAN SCALE: 1/4" = 1'-0" 3 OFFICE ELEVATION SCALE: 1/4"=1'-0" OFFICE ELEVATIONS A-3 SCALE: 1/4" = 1'-0" 2 ENLARGED OFFICE PLAN SCALE: 1/4" = 1'-0" 2'-0" SLOPE 4" x 4"x 5/16" STEEL ANGLE WELD TO CHANNELS AND TO BOTTOM CHORD OF 2 JOISTS, MIN. (VERIFY JOIST DIRECTION) 1B BY: 2'-0 SLOPE 1 3 1. WALL ASSEMBLY- THE 1 OR 2 HR FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTION FEATURES: A. STUDS- WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. OC WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN 3-5/8 IN. WIDE BY 1-3/8 IN. DEEP CHANNELS SPACED MAX 24 IN. OC. B. WALLBOARD, GYPSUM*- NOM 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES. THE GYPSUM WALLBOARD TYPE, NUMBER OF LAYERS AND SHEET ORIENTATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN. DIAM OF CIRCULAR THROUGH OPENING CUT THROUGH GYPSUM WALLBOARD ON EACH SIDE OF WALL ASSEMBLY TO BE MIN 0 IN. (POINT CONTACT) TO MAX 1 IN. LARGER THAN OUTSIDE DIAM OF FLEXIBLE METAL CONDUIT (ITEM 2) INSTALLED IN THROUGH OPENING. SIDE EDGE OF CIRCULAR OPENING TO BE MIN 3 IN. FROM NEAREST STUD IN WALL CAVITY. 17 5' LEVEL LANDING AT TOP OF RAMP 5'0 12' MINIMUM AT ENTRY AND EXIT LOCATIONS . IN M " '-0 12 N. MI " 0 5'- 6'0" LK H WA NIS . FI NC CO OOM BR P.) Y (T PE LO S ) 10 X. 1: (MA FOR STUD WALLS ONLY3/4" PLYWOOD TO 8'-0" A.F.F. INTERIOR STUD WALL OR INSULATED WALL OF COOLER AND/OR FREEZER CONTINUOUS SEALANT NEW 1/4" THICK ALUMINUM THRESHOLD SCALE: 1/2" = 1'-0" 12 SCALE: 1/2" = 1'-0" C-CHANNEL FRAME 7 SCALE: 1 1/2" = 1'-0" WALL CURB DATE: SEE FINISH SCHEDULE FOR CEILING AND A-2 FOR CEILING HEIGHT PROVIDE SOUND INSULATION FULL HEIGHT AT OFFICE PERIMETER AS INDICATED ON FLOOR PLAN VINYL BASE (VB-1) EACH SIDE FINISH FLOOR 1 "CPT-1" w/ TAPERED FRAME AT ONE (1) EDGE COORDINATE w/ EXISTING AUTOMATIC DOOR SYSTEM 3 A-4 4 A-4 3-5/8" METAL STUDS AT 24" OC. FROM TOP OF COOLER/FREEZER TO STRUCTURE ABOVE TRAFFIC DOOR - N.I.C. 4" x 18 GA. METAL STUDS @ 16" o/c C6x8.2 STEEL CHANNEL JAMBS & HEAD AT 3 5/8" WALLS - MITER TO HEAD, WELD JOINT AND GRIND SMOOTH - PAINT PER FINISH SCHEDULE EXISTING CONCRETE SLAB TRAFFIC DOOR N.I.C. 3x3x1/8 CLIP @ EACH STUD W/ 3/8" x 3" HILTI KWIK BOLT 3 EXPANSION ANCHOR INTO EXISTING CONCRETE SLAB ? WALL FINISH REFER TO FINISH SCHEDULE A6. 1/2" GYP BD VINYL BASE (VB-1) EACH SIDE FINISH FLOOR 5/8" GYP BOARD TOP OF COOLER CONTINUOUS SILL SEALER CONTINUOUS SEALANT BOTH SIDES, TYPICAL 2 WALK-IN COOLER BY OTHERS SEE FINISH SCHEDULE FOR FINISHES TYPICAL EACH SIDE OF WALL 13 TRAFFIC DOOR JAMB / HEAD SCALE: 1 1/2" = 1'-0" 8 SCALE: 1 1/2" = 1'-0" PARTIAL HEIGHT WALL 2 PARTITION ABOVE COOLER STEEL STUDS - CHANNEL SHAPED, FABRICATED FROM MIN. 25 MSG (MIN. 20 MSG WHEN ITEM 4A IS USED) CORROSION-PROTECTED STEEL, MIN. WIDTH AS INDICATED UNDER ITEM 4, MIN. 1 1 4" FLANGES AND RETURN, SPACED A MAX. OF 24 IN. O.C. STUDS TO BE CUT 3 8" TO 3 4" LESS THEN ASSEMBLY HEIGHT. ROOF DECK INTERIOR PARTITION- AS SCHEDULED BATTS AND BLANKETS (OPTIONAL) - PLACED IN STUD CAVITIES, ANY GLASS FIBER OR MINERAL WOOL INSULATION BEARING THE UL CLASSIFICATION MARKING AS TO SURFACE BURNING CHARACTERISTICS AND / OR FIRE RESISTANCE. PAINTED HOLLOW METAL FRAME - VERIFY WALL THICKNESS ON SHEET A-1 2 1/2" POST FURNISHED BY SAVE-A-LOT ADJUSTABLE BUMPER WALLBOARD PROTECTION ON EACH SIDE OF WALL OPTIONAL CANADIAN GYPSUM CO. - 1 2" THICK TYPE C, WRC OR IP-X2; 5 8" THICK TYPE SCX, SHX, WRX, IP-X1, AR, C, WRC OR IP-X2; 3 4" THICK ULTRACODE OR TYPE IP-X3. UNITED STATES GYPSUM CO. - 1 2" THICK TYPE C, WRC OR IP-X2; 5 8" THICK TYPE SCX, SHX, WRX, IP-X1, AR, C, WRC OR IP-X2; 3 4" THICK ULTRACODE OR TYPE IP-X3. (WINDOW HEAD DETAIL SIMILAR) 14 SCALE: 1 1/2" = 1'-0" WINDOW JAMB DETAIL YESO PANAMERICANO SA DE CV - 1 2" THICK TYPE C, WRC OR IP-X2; 5 8" THICK TYPE SCX, SHX, WRX, IP-X1, AR, C, WRC OR IP-X2; 3 4" THICK ULTRACODE OR TYPE IP-X3. 9 SCALE: 1/2" = 1'-0" CASE PROTECTOR PIPE / CONDUIT 3 PARTITION AT ROOF DECK FILL SOLID WITH 2500 psi CONCRETE & ROUND TOP CONTINUOUS 20 GAGE GALVANIZED SHEET METAL FASTEN TO DECK VALLEYS 4" dia STANDARD PIPE SCHEDULE 40 BOLLARD PAINT OSHA YELLOW ROOF DECK MASTIC SEALANT WALLBOARD, GYPSUM - (AS AN ALTERNATE TO ITEM 4) 5 8" THICK GYPSUM PANELS, INSTALLED AS DESCRIBED IN ITEM 4 WITH TYPE S-12 STEEL SCREWS. THE LENGTH AND SPACING OF THE SCREWS AS SPECIFIED UNDER ITEM5. STAINLESS STEEL RING CLAMP CANADIAN GYPSUM COMPANY - TYPE FRX. MANUFACTURED PIPE BOOT WITH LAP SPLICE UNITED STATES GYPSUM COMPANY - TYPE FRX. MEMBRANE ROOF ASSEMBLY FASTENERS - TYPE S OR S-12 STEEL SCREWS USED TO ATTACH PANELS TO STUDS (ITEM 2) OR FURRING CHANNELS (ITEM 6). SINGLE LAYER SYSTEMS - 1" LONG FOR 1 2" AND 5 8" THICK PANELS OR 1 1 4" LONG FOR 3 4" PANELS, SPACED 8" O.C. WHEN PANELS ARE APPLIED HORIZONTALLY, OR 12" O.C. WHEN PANELS ARE APPLIED VERTICALLY. TWO LAYER SYSTEMS - FIRST LAYER- 1" LONG FOR 1 2" AND 5 8" THICK PANELS OR 1 1 4" LONG FOR 3 4" THICK PANELS, SPACED 16" O.C. SECOND LAYER- 1 5 8" LONG FOR 1 2" AND 5 8" THICK PANELS OR 2 1 4" LONG FOR 3 4" THICK PANELS, SPACED 16" O.C. WITH SCREWS OFFSET 8" FROM FIRST LAYER. ? JOINT FILLER, TYP ? REMOVE AND REPLACE EXISTING CONCRETE FLOOR AS REQUIRED STEEL JOIST TOP CHORD 18 GAGE BY 3" DEEP LEG TRACK 1'-4" dia 2500 psi POURED CONCRETE 6" ROOF DECK FASTENERS INTO METAL STUD ONLY, AT 5" BELOW ROOF DECK. (CLEAR TRACK BY 1" MINIMUM). STEEL BAR JOIST BEYOND 5 8. 9. ADHERED FLEXIBLE FLASHING WITH LAP SPLICE - EXTEND TO TOP OF CURB SIDING, BRICK OR STUCCO - (OPTIONAL) ALUMINUM, VINYL OR STEEL SIDING, BRICK VENEER OF STUCCO, MEETING THE REQUIREMENTS OF LOCAL CODE AGENCIES, INSTALLED OVER GYPSUM PANELS. BRICK VENEER ATTACHED TO STUDS WITH CORRUGATED METAL WALL TIES ATTACHED TO EACH STUD WITH STEEL SCREWS, NOT MORE THAN EACH SIXTH COURSE OF BRICK. MEMBRANE ROOF ASSEMBLY 2" x FIRE RETARDANT WOOD CURB WITH GALV. SCREWS THROUGH DECK AT 12" o/c MAX. CAULKING AND SEALANTS - (OPTIONAL) A BEAD OF ACOUSTICAL SEALANT APPLIED AROUND PERIMETER FOR SOUND CONTROL. ? SCALE: 1 1/2" = 1'-0" 1x4 WOOD TRIM - CONT. TWO WALLS FASTEN TO METAL STUDS AT 16" O.C. 6" dia STANDARD PIPE SCHEDULE 40 BOLLARD PAINT OSHA YELLOW 16 MULTI-PIPE PENETRATION SCALE: 1" = 1'-0" 11 REMOVE AND REPLACE EXISTING PAVEMENT AS REQUIRED EXTERIOR BOLLARD STORE NUMBER PROJECT NUMBER 12" HEAVY-DUTY, VINYL OR EPOXY COATED WIRE SHELVING AT 6'-0" A.F.F. HANGING PINS FOR CLIP BOARDS BETWEEN BRACES AT 12" o/c 03510-01 SHEET TITLE DIAGONAL BRACES AT 12" o/c 1x4 WOOD TRIM - CONT. TWO WALLS DETAILS FINISH FLOOR 2'-0" dia 4000 psi AIR-ENTRAINED POURED CONCRETE SHEET NUMBER STEEL JOIST BEYOND NON BEARING WALL RATING - 1 HOUR 23 1 - HOUR RATED DEMISING WALL PARTITION AT ROOF DECK JOINT FILLER, TYP ROOF DECK UL SYSTEM NO. U419 4 FILL SOLID WITH 2500 psi CONCRETE & ROUND TOP BATT INSULATION - FILL ALL VOIDS UNITED STATES GYPSUM CO. - TYPE AS - BEARING THE UL CLASSIFICATION MARKING. SCALE: 1/2" = 1'-0" INTERIOR BOLLARD TYPICAL REFRIGERATION PIPING N.I.C. (WITH INSULATION ON RETURN LINES) - VERIFY SIZE & QTY OF PIPES. 4" ARMAFLEX SLEEVE AT EACH PIPE & EXPANSIVE FOAM TYPICAL TO SEAL ALL PENETRATIONS JOINT TAPE AND COMPOUND - VINYL OR CASEIN, DRY OR PREMIXED JOINT COMPOUND APPLIED IN TWO COATS TO JOINTS AND SCREW HEADS OF OUTER LAYERS. PAPER TAPE, NOMINALLY 2" WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND OVER ALL JOINTS OF OUTER PANELS. 10 N.T.S. REMOVABLE, GALVANIZED CAP WITH 2" OVERHANG EACH SIDE. SECURE TO FIRE RETARDANT WOOD CURBS WITH GALV. SCREW FASTENERS AT 12" o/c MAX SCALE: 1"= 1'-0" 6'-0" 7. FURRING CHANNELS - (OPTIONAL FOR SINGLE OR DOUBLE LAYER SYSTEMS) RESILIENT FURRING CHANNELS FABRICATED FROM MIN. 25 MSG CORROSION-PROTECTED STEEL, SPACED VERTICALLY A MAX. OF 24" O.C. FLANGE PORTION ATTACHED TO EACH INTERSECTION STUD WITH 1 2" LONG TYPE S-12 STEEL SCREWS. NOT FOR USE WITH ITEM 4A. SINGLE PENETRATION N.T.S. 6. 15 4'-6" FOUR LAYER SYSTEMS - FIRST LAYER- 1" LONG FOR 1 2" AND 5 8" THICK PANELS, SPACED 24" O.C. SECOND LAYER- 1 5 8" LONG FOR 1 2" AND 5 8" THICK PANELS SPACED 24" O.C. THIRD LAYER- 2 1 4" LONG FOR 1 2" THICK PANELS OR 2 5 8" LONG FOR 5 8" THICK PANELS SPACED AT 24" O.C. FORTH LAYER- 2 5 8" LONG FOR 1 2" THICK PANELS OR 3" LONG FOR 5 8" THICK PANELS, SPACED AT 12" O.C. SCREWS OFFSET MIN. 6" FROM LAYER BELOW. METAL STUD PARTITION 5'-6" THREE LAYER SYSTEMS - FIRST LAYER- 1" LONG FOR 2" AND 8" THICK PANELS SPACED 24" O.C. SECOND LAYER- 1 5 8" LONG FOR 1 2" AND 5 8" THICK PANELS, SPACED 18" O.C. THIRD LAYER2 1 4" LONG FOR 1 2" AND 5 8" THICK PANELS OR 2 5 8" LONG FOR 5 8" THICK PANELS, SPACED 12" O.C. SCREWS OFFSET MIN. 6" FROM LAYER BELOW. 6" 1 SCALE: 1 1/2" = 1'-0" SCALE: 1/2" = 1'-0" 5 SHELVING DETAIL SCALE: 1 1/2" = 1'-0" A-4 ALEXANDER CITY, AL THICK DRAWN: 8" N.T.S. 5 FASTENERS INTO METAL STUD ONLY AT 5" BELOW ROOF DECK. (CLEAR TRACK BY 1" MINIMUM) METAL STUD PARTITION N.T.S. 1 LAYER, 18 GAGE BY 3" DEEP LEG TRACK 3/4" x 1/2" APPLIED STOP (TYPICAL) 4'-0" 3 1 2" ? FINISH FLOOR MIN. THICKNESS OF INSULATION 2'-0" 1 MIN. STUD DEPTH CORE DRILL OVERSIZED HOLE AND SET POST IN NON-SHRINK GROUT (POROCK OR EQUAL) CONTINUOUS SEALANT AT AIRTIGHT PARTITIONS 08/23/10 CONTINUOUS SEALANT AT PERIMETER OF BOTH SIDES OF FRAME - TYPICAL 1/4" ONE-WAY MIRRORED GLASS, PROVIDE TEMPERED GLASS WHEN WINDOW IS ADJACENT TO DOOR AS REQUIRED BY CODE. 4 -3/8" x 3" DYNABOLTS OR EQUAL DATE: WALLBOARD, GYPSUM - GYPSUM PANELS WITH BEVELED, SQUARE OR TAPERED EDGES, APPLIED VERTICALLY OR HORIZONTALLY. VERTICAL JOINTS CENTERED OVER STUDS AND STAGGERED ONE STUD CAVITY ON OPPOSITE SIDES OF STUDS. VERTICAL JOINTS IN ADJACENT LAYERS (MULTILAYER SYSTEMS) STAGGERED ON STUD CAVITY. HORIZONTAL EDGE JOINTS AND HORIZONTAL BUTT JOINTS ON OPPOSITE SIDES OF STUDS NEED NOT BE STAGGERED. HORIZONTAL EDGE JOINTS AND HORIZONTAL BUTT JOINTS IN ADJACENT LAYERS (MULTILAYER SYSTEMS) STAGGERED A MIN. OF 12 IN. THE THICKNESS AND NUMBER OF LAYERS FOR THE 1 HOUR RATING IS AS FOLLOWS: # OF LAYERS AND THICKNESS OF PANELS SCALE: 1 1/2" = 1'-0" 1612 MILLS SQUARE SCALE: 1 1/2" 1'-0" FULL = SCALE GAT FLOORAT TRANSITION JAMB NEW CMU OPENING CHECKED: 19 EXPOSED INSULATED PANELS NIC BLM FLOOR AND CEILING RUNNERS - CHANNEL SHAPED, FABRICATED FROM MIN. 25 MSG (MIN. 20 MSG WHEN ITEM 4A IS USED) CORROSION-PROTECTED STEEL, MIN. WIDTH TO ACCOMMODATE STUD SIZE, WITH MIN. 1 IN. LONG LEGS, ATTACHED TO FLOOR AND CEILING WITH FASTENERS 24 IN. O.C. MAX. RATING SCALE: 1/2" = 1'-0" UNDERSIDE OF METAL DECK BASE COVER 5. INTERIOR FULL HEIGHT WALL 1x6 WOOD TRIM. PAINT (PT-1) SEE BATTS AND BLANKETS (BKNV OR BZJZ) CATEGORIES FOR NAMES OF CLASSIFIED COMPANIES. 4A. 6" METAL STUDS @ 16" o/c WITH 5/8" TYPE "X" GYP. BD. EACH SIDE SEE FINISH SCHEDULE FOR WALL FINISH 4"x4" WOOD WALL GUARD w/ FIRE RETARDANT PAINT ALL SURFACES C6x8.2 STEEL CHANNEL JAMBS AT 3 5/8" STUD WALLS, FROM FINISHED FLOOR TO ROOF STRUCTURE NEW BENT PLATE 1 1/2" x 12" x 3/16" FROM FINISHED FLOOR TO BOTTOM OF STEEL LINTEL w/ 1/2" dia x 4" HEADED STUDS @ 2'-0" o/c - PAINT EXPOSED STEEL LINTEL AND BENT PLATE JAMB, TYP OPTIONAL DETAILS FOR USE WHEN RATED WALL IS REQUIRED BY CODE 4. GYP. BOARD TO EXISTING GRID 1/2" dia x 6" ANCHORS @ 24" o/c - w/2 1/2" EMBEDMENT FINISH FLOOR BREAK EXISTING CMU AT NEAREST EXISTING JOINT LINE. GROUT JAMBS SOLID EACH SIDE OF DOOR OPENING FULL HEIGHT NEW SURFACE MOUNTED 4 3A. VERIFY EXISTING GRID TO REMAIN GYP BOARD TO 6" ABOVE NEW CEILING 13 A-4 4" x 4" x 5/16" x 4" STEEL CLIP ANGLE WELD TO CHANNEL AND ANCHOR TO FLOOR WITH 5/8" x 4" HILTI KWIK BOLT 3 EXPANSION ANCHORS SCALE: 1 1/2" = 1'-0" NOTE: 4000 PSI (MIN.) AIR-ENTRAINED CONCRETE 22 RATED WALL PENETRATION DETAIL 2. ANGLE BUMPER @ WALLS METAL STUD PARTITION AS SCHEDULED 1 OR 2 HOUR WALL PENETRATION 1. NOTE 2: ENTIRE RAMP SURFACE (OUTSIDE OF DETECTABLE WARNING) SHALL CONTRAST IN COLOR BY 70% FROM THAT OF THE SIDEWALK. RECOMMENDED COLORS ARE RED OR YELLOW TO MATCH THE COLOR CHOSEN FOR THE DETECTABLE WARNING MAT. 18 FLARED H.C. RAMP UL SYSTEM NO. WL-1017 4 NOTE: PAINT ALL EXPOSED STEEL 6 RAMP AND FLARES SHALL CONTRAST VISUALLY WITH ADJOINING SURFACES. (LIGHT-ON-DARK OR DARK-ON-LIGHT). PE LO S ) 10 X. 1: (MA MINNESOTA MINING & MFG. CO. - CP 25WB+ *BEARING THE UL CLASSIFICATION MARKING 3A C6x8.2 STEEL CHANNEL JAMBS AT 6" STUD WALLS, FROM FINISHED FLOOR TO ROOF STRUCTURE NOT USED CO 1: NC (M 12 S RA AX LO MP .) PE TH WI T H AL US FL SPH A 2. THROUGH PENETRATING PRODUCT*- FLEXIBLE METAL CONDUIT-NOM 4 IN. DIAM (OR SMALLER) ALUMINUM OR STEEL FLEXIBLE METAL CONDUIT+. MAX ONE FLEXIBLE METAL CONDUIT TO BE INSTALLED NEAR CENTER OF CIRCULAR OPENING IN GYPSUM WALLBOARD. FLEXIBLE METAL CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. AFC CABLE SYSTEMS, INC. 3. FILL, VOID OR CAVITY MATERIAL*- CAULK-CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE AROUND ENTIRE CIRCUMFERENCE OF THROUGH PENETRATING PRODUCT TO COMPLETELY FILL OPENING IN GYPSUM WALLBOARD LAYERS ON EACH SIDE OF THE WALL ASSEMBLY. A MIN 5/8 IN. THICKNESS OF CAULK IS REQUIRED FOR THE 1 HR F RATING. A MIN 1-1/4 IN. THICKNESS OF CAULK IS REQUIRED FOR THE 2 HR F RATING. NOTE 1: CONSTRUCT RAMP TO LEAST POSSIBLE SLOPE (MAX = 1:12). CROSS SLOPE OF RAMP AND LANDING SHALL NOT EXCEED 1:50. 6" C. FASTENERS- WHEN WOOD STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH CEMENT COATED NAILS AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. WHEN STEEL CHANNEL STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS WITH TYPE S SELF-DRILLING, SELF-TAPPING BUGLE-HEAD STEEL SCREWS AS SPECIFIED IN THE INDIVIDUAL WALL OR PARTITION DESIGN. " SCALE: 1" = 1'-0" TYPICAL FLOOR DRAIN 2' DETECTABLE WARNING GROOVES PER LOCAL JURISDICTION OPTION TO WELD C-CHANNEL TO 16 GAGE METAL STUD FRAME AT TOP OF COOLER LINE. PRELIMINARY NOT FOR BID OR CONSTRUCTION CFM/SQ FT L RATING C "COMPANY NAME" 20XX ALL RIGHTS RESERVED CONTRACTOR TO REMOVE EXISTING CONCRETE 2'-0" SQUARE AROUND NEW & EXISTING FLOOR DRAINS OR FLOOR SINKS. SET DRAIN OR SINK AND REPAIR CONCRETE WITH POSITIVE SLOPE TO DRAIN / SINK. VERIFY WL SYSTEM NO. W-L-1017 (FORMERLY SYSTEM NO. 328) F RATINGS1 AND 2 HR. (SEE ITEM 3) T RATING-0 HR L RATING AT AMBIENT-LESS THAN 1 AT 400 F-LESS THAN 1 CFM/SQ FTLL BREAK EXISTING CEILING GRID AS REQUIRED FOR NEW WALL BRACING DESCRIPTION: 3M FIRE PROTECTION PRODUCTS THIS MATERIAL WAS EXTRACTED BY 3M FIRE PROTECTION PRODUCTS FROM THE 1997 EDITION OF THE UL FIRE RESISTANCE DIRECTORY. 345 METALLIC PIPE 1OOO SERIES FINISH FLOOR SLOPE 1C 7 SLOPE SLOPE 3 SLOPE REV. NUMBER: SLOPE 2'-0" 2'-0" SLOPE CONT. L-4"x 4"x 1/4" STEEL TURN TO BE 4" AWAY FROM COOLER WALL w/ 3 8" dia ANCHORS @ 24" o/c INTO EXISTING FLOOR SLAB CERTIFICATION: 2 AUTOMATIC ENTRANCE DOORS PRODUCTS BY FERGUSON OR EQUAL. BESAM AUTOMATED ENTRANCE SYSTEMS, INC.; AN ASSA ABLOY GROUP COMPANY. STANLEY ACCESS TECHNOLOGIES; A DIVISION OF THE STANLEY WORKS. PROVIDE MANUFACTURER'S STANDARD AUTOMATIC SLIDING OR SWINGING ENTRANCES INCLUDING DOORS (AS SHOWN ON DRAWINGS), SIDE LITES, FRAMING, HEADERS, CARRIER ASSEMBLIES, ROLLER TRACKS, DOOR OPERATORS, ACTIVATION AND SAFETY DEVICES, AND ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION. EMERGENCY BREAKAWAY CAPABILITY: SLIDING/SWINGING LEAF (LEAVES) AND SIDELITE(S). STANLEY ACCESS TECHNOLOGIES SENTREX 3 MOTION/PRESENCE DETECTION. MEDIUM STILE OR MATCH EXISTING ON EXTERIOR DOORS, PROVIDE ADAMS RITE MODEL MS 1850-OS-050 SERIES DEADLOCKS WITH CYLINDERS THAT ACCEPT BEST INTERCHANGEABLE CORES. PROVIDE STEEL ARMORED STRIKE REINFORCING PLATE SURROUNDING LOCK STRIKE OPENING AND SCREW FASTENED INSIDE OF ALUMINUM MEMBER. PROVIDE CYLINDER INSIDE AND OUTSIDE ON DOOR DESIGNATED BY PROJECT MANAGER, AT OTHER EXTERIOR DOORS, PROVIDE CYLINDER INSIDE ONLY WITH NO CUTOUTS ON OUTSIDE OF DOOR. EXTRUDED-ALUMINUM RAISED THRESHOLDS; WITH BEVELED EDGES WITH SLOPE OF NOT MORE THAN 1:2 AND MAXIMUM HEIGHT OF 1/2 INCH MANUFACTURER'S STANDARD WEATHER STRIPPING, BRUSH SWEEP, FINGER GUARDS, GUIDE RAILS (FOR SWINGING DOORS), CART CRASH BARS DOOR HARDWARE PROVIDE GRADE 1 DOOR HARDWARE TYPES AS SCHEDULED ON THE DRAWINGS PRODUCTS BY INGERSOLL-RAND AND ITS SUBSIDIARY BRANDS OR EQUALS. EQUIP LOCKS WITH SPECIFIED CYLINDERS FOR BEST ACCESS SYSTEMS' INTERCHANGEABLE-CORE 7-PIN TUMBLER INSERTS. OWNER WILL PROVIDE CONSTRUCTION CORES AND KEYS. OWNER WILL PROVIDE PERMANENT CORES AND KEYS. GENERAL CONTRACTOR SHALL OBTAIN PURCHASE ORDER FOR PUBLIC SAFETY KEY BOX FROM CITY FIRE MARSHALL, AND SHALL PROVIDE KEY BOX IN LOCATION COORDINATED WITH CITY FIRE MARSHALL. TOILET ACCESSORIES TOILET PAPER HOLDER, MULTI-ROLL SURFACE MOUNTED, DUAL ROLL TYPE WITH CONTROLLED DELIVERY OPERATION; CAST ALUMINUM, SATIN FINISH. BOBRICK WASHROOM EQUIPMENT, INC.: NO. B-274 OR EQUAL. EXIST. EXIST. EXIST. EXIST. EXIST. EXIST. 5 100 VESTIBULE CONC. 103A 3'-0" x 7'-0" OFFICE NEW H.M. PT-3 C H.M. PT-3 C HW-5 2&8 101 SALES AREA CONC. VCT-1 GYP. BD. 104A 3'-0" x 7'-0" BREAK ROOM NEW H.M. PT-3 D H.M. PT-3 C HW-6 8 102 SAFE CONC. VCT-1 GYP. BD. FRP-1/PT-1 111A PAIR 3'-0" x 8'-0" BREAK ROOM NEW UNIFLEX FACTORY B STEEL PT-3 B BY MFR. 103 OFFICE CONC. VCT-1 GYP. BD. 114A 3'-0" x 7'-0" MEN NEW H.M. PT-3 C H.M. PT-3 C HW-4 4 104 BREAK ROOM CONC. VCT-1 116A 3'-0" x 7'-0" RECEIVING NEW H.M. PT-3 E H.M. PT-3 C HW-7 1, 3, 8 & 9 105 CORRIDOR "A" CONC. 117A 3'-0" x 7'-0" BACK ROOM "B" NEW H.M. PT-3 E H.M. PT-3 C HW-7 1, 3 & 8 106 CORRIDOR "B" - NOT USED 107 DAIRY COOLER 108 HARDWARE PACKAGES HW-1 - (STOREFRONT) DOORS ARE TO BE SENSOR ACTIVATED WITH SENSOR SAFETIES. ASSEMBLY SHALL BE EQUIVALENT TO "STANLEY SENTREX 3" OPERATION AND CRASH BARS BY DOOR MFR. U.N.O. MUST COMPLY WITH LOCAL CODES 1 CYLINDER KEY / KEY LOCK (7 PIN) TO BE RE-KEYED PER P.M. HW-2 - (EXIT DOOR) 112 PR HINGES (HAGER BB1279 US26D- 4 1/2") 3 SILENCERS 1 CLOSER (LCN 1461xALUMxTB) 1 DOOR SWEEP (PEMKO 315CN x DOOR WIDTH) 1 THRESHOLD (PEMKO 170A x DOOR WIDTH EXIT DEVICE (DETEX HARDWARE- MODEL#V40xEMxALxRWE) WEATHER-STRIPPING (PEMKO 303AV) 1 RAIN DRIP CAP (PEMKO 3464 x DOOR WIDTH) 1 LATCH GUARD (WILMONT) HW-3 - (OVERHEAD DOOR) ALL HARDWARE BY MFR. U.N.O. 1 BEST SHANK PADLOCK (2") KEYED TO MATCH FRONT DOORS HW-4 - (REST ROOMS) 112 PR HINGES (HAGER BB1279 US26D- 4 1/2") 1 CLOSER (LCN 1461 ALUM) - MOUNT TO INSIDE OF DOOR 1 PRIVACY LEVER LOCK SET (SCHLAGE AL405 SAT 626) 3 SILENCERS 1 WALL STOP (ROCKWOOD 406x630) HW-5 - (OFFICE) 112 PR HINGES (HAGER 1279 US26D- 4 1/2") 1 SELF-LOCKING LEVER LOCKSET, KEY IN LEVER (SCHLAGE AL70PD SAT 626) 1 CLOSER (LCN 1461 ALUM) - MOUNT TO INSIDE OF DOOR 3 SILENCER 1 WALL STOP (ROCKWOOD 409x960) DOOR TYPES DOOR TYPES: A. B. C. D. E. F. G. NOT USED. UNI-FLEX DOORS, PROVIDED BY SAVE-A-LOT. 3'-0" X 7'-0" HOLLOW FLUSH STEEL DOOR WITH WALL BUMPER. 3'-0" X 7'-0" HOLLOW FLUSH STEEL DOOR WITH 24" X 36" WINDOW AND WITH WALL BUMPER. 3'-0" X 7'-0" INSULATED FLUSH STEEL DOOR. NOT USED. NOT USED. HW-6 - (BREAK ROOM) 112 PR HINGES (HAGER 1279 US26D- 4 1/2") 1 PASSAGE LEVER LATCH SET (SCHLAGE AL105 SAT 626) 1 CLOSER (LCN 1461 SLUM) - MOUNT TO INSIDE OF DOOR 1 WALL STOP (ROCKWOOD 406x630) 3 SILENCERS HW-7 - (BACK ROOM EXIT) 1 1/2 PR HINGES (HAGER BB1279 US26D- 4 1/2") 3 SILENCERS 1 CLOSER (LCN 1461xALUMxTB) 1 DOOR SWEEP (PEMKO 315CN x DOOR WIDTH) 1 THRESHOLD (PEMKO 170A x DOOR WIDTH EXIT DEVICE (DETEX HARDWARE- MODEL#V40xEMxALxRWE) WEATHER-STRIPPING (PEMKO 303AV) 1 RAIN DRIP CAP (PEMKO 3464 x DOOR WIDTH) 1 LATCH GUARD (WILMONT) 1 ASTRAGAL 1 COORDINATOR (LCN) DOOR GENERAL NOTES 1. 2. 3. 4. 5. 6. 7. 8. ALL EXISTING DOORS AND FRAMES TO REMAIN SHALL BE PAINTED. ALL DOOR HARDWARE SHALL BE OILED AND / OR GREASED TO INSURE PROPER WORKING ORDER. REPAIR AS REQUIRED TO MEET REQUIREMENTS OF INTERNATIONAL BUILDING CODE SECTION 1003.3 AND SUBSECTION 1003.3.1.2 AND ANSI 117.1-98 SECTION 404 AND SUBSECTION 404.2.7 AND LOCAL CODE REQUIREMENTS. ALL DOORS, FRAMES AND HARDWARE SHALL BE COMMERCIAL STANDARD UNLESS NOTED OTHERWISE. ALL DOOR LOCKS SHALL BE RE-KEYED SEPARATELY. VERIFY w/ SAVE-A-LOT (SAL) CONSTRUCTION PROJECT MANAGER. HOLLOW METAL FRAMES SHALL BE STEEL-CRAFT 16 GAUGE HOLLOW METAL. COOLER / FREEZER DOORS TO BE PROVIDED BY COOLER / FREEZER MANUFACTURER. PROVIDE NEW WEATHER STRIPING ON EXISTING EXTERIOR DOORS TO ENHANCE VECTOR CONTROL. UNI-FLEX DOORS PROVIDED BY SAVE-A-LOT w/ HINGES INSTALLED BY GENERAL CONTRACTOR PER MANUFACTURER INSTRUCTIONS (SUPPLIED w/ DOORS) INTO G.C. PROVIDED STEEL CHANNEL FRAMES. REQUESTS FOR SUBSTITUTION OF MATERIALS FROM ALTERNATE MANUFACTURERS SHOULD BE SUBMITTED WITH YOUR BID. DOOR FRAME TYPES DOOR SCHEDULE KEY NOTES FRAME TYPES: 1. PROVIDE SILLS AT NEW DOOR OPENINGS. A. B. 2. DOOR FRAME FOR 6" STUD WALL WITH GYP. BD. EACH SIDE. 3. PAINT EXTERIOR OF DOOR & FRAME PER SAL PROJECT MANAGER DIRECTIONS. PAINT INTERIOR AS SCHEDULED. C. NOT USED. STEEL CHANNEL FRAME. INSTALLATION REQUIRES 4 LAG BOLTS FOR EACH HINGE, ONE HINGE PER DOOR LEAF. SEE DETAIL 13/A-4. 3'-0" x 7'-0" x 2" STEEL DOOR FRAME, PROVIDE 4" HEAD AT MASONRY OPENINGS. HARDWARE MUST COMPLY WITH LOCAL CODES AND A.D.A. REQUIREMENTS. 5. REFURBISH EXISTING AUTOMATIC DOORS. DOORS ARE TO BE SENSOR ACTIVATED w/ SENSOR SAFETIES. FINISHED ASSEMBLY SHALL BE EQUIVALENT TO "STANELY SENTREX 3". 6. NOT USED. 7. NOT USED. MIRROR WITH FRAME - WITHOUT SHELF SIZE: 24 INCHES WIDE BY 36 INCHES HIGH. AMERICAN SPECIALTIES, INC.: NO. 0600 SERIES OR EQUAL. 8. PROVIDE A KICK PLATE ON THE PUSH SIDE OF THE DOOR. 9. VERIFY IF DOOR VIEWER AND DOOR BUZZER ARE REQUIRED w/ SAVE-A-LOT (SAL) CONSTRUCTION PROJECT MANAGER. SANITARY NAPKIN DISPOSAL: SURFACE MOUNTED FEMININE NAPKIN DISPOSAL, 304 STAINLESS STEEL, SATIN FINISH; TOP DOOR WITH HANDLE; BOTTOM DOOR, HELD IN CLOSED POSITION WITH LOCK OR LATCH; VINYL LINER IN CONTAINER BOBRICK WASHROOM EQUIPMENT, INC.: NO. B-270 OR EQUAL. 10. NOT USED. DIAPER CHANGING STATION: HORIZONTAL, SURFACE-MOUNTED DESIGN; MADE OF HIGH-IMPACT POLYETHYLENE. PROVIDE COMPLETE WITH SAFETY STRAPS AND SANITARY BED LINER DISPENSER. NOMINAL 35 INCHES BY 20 INCHES BY 4 INCHES DEEP IN CLOSED POSITION, 20 INCHES DEEP WHEN OPENED. DIAPER DEPOT # 4300, BOTTOM MOUNTED 34" ABOVE FINISHED FLOOR. WARM-AIR DRYER: PROVIDE HAND DRYER IN PUBLIC RESTROOMS AT LOCATIONS INDICATED ON DRAWINGS. ACTIVATED BY INFRARED OPTICAL SENSOR WHICH SHALL OPERATE AS LONG AS HANDS ARE UNDER THE DRYER WITH 35-SECOND LOCKOUT IF HANDS ARE NOT REMOVED. ELECTRICAL REQUIREMENTS: 110 / 120V, 12.5A, 1500 W EXCEL DRYER INC: MODEL XL-W XLERATOR OR EQUAL. CPT-1/VCT-1 EXIST./GYP. FRP-1/PT-1 CEILING BASE MATL. FINISH VB-1 EXIST. EXIST. FRP-1/PT-1/2 VB-1 EXIST. EXIST. VB-1 EXIST. EXIST. PT-1 VB-1 ACP-1 FACTORY GYP. BD. PT-1 VB-1 ACP-1 FACTORY VCT-1 GYP. BD. FRP-1/PT-1 VB-1 EXIST. PT-1 CONC. CS-1 PRE-FAB. FACTORY PRE-FAB. PRE-FAB. FACTORY MEAT PREP CONC. QT-1 PRE-FAB. FACTORY QT-1 PRE-FAB. FACTORY 109 MEAT COOLER CONC. QT-1 PRE-FAB. FACTORY QT-1 PRE-FAB. FACTORY 110 FREEZER PRE-FAB. FACTORY PRE-FAB. FACTORY PRE-FAB. PRE-FAB. FACTORY 111 BACK ROOM "A" CONC. VCT-1 EXIST./GYP. PL-1/PT-1 WB-1 EXIST. EXIST. 112 PRODUCE PREP AREA CONC. CS-1 GYP. BD. FRP-1 VB-1 ACP-2 FACTORY 113 PRODUCE COOLER CONC. CS-1 PRE-FAB. FACTORY PRE-FAB. PRE-FAB. FACTORY 114 MEN CONC. VCT-1 GYP. BD. FRP-1 VB-1 GYP. BD. PT-1 115 WOMEN CONC. VCT-1 GYP. BD. FRP-1 VB-1 GYP. BD. PT-1 116 RECEIVING CONC. CS-1 EXIST. PL-1/PT-1 WB-1 EXIST. EXIST. 117 BACK ROOM "B" CONC. CS-1 EXIST./GYP. PL-1/PT-1 WB-1 EXIST. EXIST. 118 STORAGE CONC. VCT-1 EXIST. PT-1 VB-1 EXIST. PT-1 119 RECEIVING CONC. CS-1 EXIST. PT-1 VB-1 EXIST. EXIST. FINISH SCHEDULE KEY VCT-1: VINYL COMPOSITION TILE - 1/8" x 12" x 12" ARMSTRONG IMPERIAL TEXTURE #52507 "FESTIVE IVORY". USE ARMSTRONG ADHESIVES APPROPRIATE FOR THIS APPLICATION: S-515, S-700, OR S-750. USE S-230 ADHESIVE FOR WET AREAS. PROVIDE 1/8" HEAVY DUTY DIAMOND PLATE TRANSITION ABUTTING THE TILE EDGE AND FLUSH WITH THE TILE SURFACE BETWEEN TILE AND CONCRETE. FASTEN TRANSITION PLATE w/ 1/4" DRIVE PINS . VB-1: VINYL COVE - ARMSTRONG #76, 4" HIGH 1/8" GAUGE DEEP BROWN VINYL COVE BASE. USE ARMSTRONG S-725 ADHESIVE FOR COLOR INTEGRATED WALL BASE. 1. 2. PC-1: POLISHED CONCRETE - NOT USED. QT-1: QUARRY TILE - STANDARD SMOOTH SURFACED 6" x 6" x 1/2" RED QUARRY TILE FLOOR WITH CARBORUNDUM CHIPS AND BASE WITH EPOXY GROUT COLOR TO MATCH TILE. GROUT JOINTS ARE TO BE 1/4" WIDE AND THE GROUT IS TO BE FLUSH w/ FINISHED FLOOR. PROVIDE HEAVY DUTY DIAMOND PLATE TRANSITION BETWEEN QUARRY TILE AND CONCRETE AT DOORWAYS. INSTALL THE TRANSITION OVER NON-SHRINK GROUT AND FASTEN SECURELY TO THE FLOOR. THE TRANSITION SHOULD FINISH SLIGHTLY ABOVE THE SURFACE OF THE QUARRY TILE. ACP-1: ACOUSTICAL CEILING PANELS - ARMSTRONG #1729 FINE FISSURED 24" x 48" x 5/8" CLASS A WITH HUMIGUARD PLUS PERFORMANCE. PRODUCT SHALL HAVE UL CLASSIFIED NRC OF .55. NO SUBSTITUTIONS ALLOWED. WHERE NEEDED SUSPENSION SYSTEMS SHALL BE ARMSTRONG PRELUDE 15/16" HOT-DIPPED GALVANIZED, ROTARY STITCHED, PEAKFORM TYPE MATERIAL. NO SUBSTITUTIONS. 3. 4. 5. 6. ACP-2: ACOUSTICAL CEILING PANELS - ARMSTRONG #670 24" x 48" VINYL-CLAD GYPSUM BOARD NON-ABSORBENT SUSPENDED CEILING TILE. FRP-1: "KEMLITE" PANELING - KEMLITE GLASBORD w/ SURFASEAL, #84 "IVORY", PEBBLED EMBOSSED. WB-1: WOOD BASE - WALL GUARD- 4x4 PAINT TO MATCH ADJACENT WALL. SEE DETAIL 7/A-4. PL-1: PLYWOOD WAINSCOT - 4'-0" A.F.F. WAINSCOT OF 3/4" PLYWOOD ON EXPOSED GYPSUM BOARD WALLS. PAINT PT-1. 7. CPT-1: CARPET TILE - CONTACT CRYSTAL BROOKS (972-429-5777) AT GRAND ENTRANC E. PT-1: SHERWIN WILLIAMS SW 6148 WOOL SKEIN, OR BENJAMIN MOORE OC-11 CLAY BEIGE - USE AT GYPSUM DRYWALL (SALES AREA, BACK ROOM AREA, OFFICE, BREAK ROOM, INTERIOR COLUMNS, RESTROOMS AND RESTROOM CEILINGS WHEN DRYWALL): TWO FINISH COATS OVER AN EXISTING FINISH OR PRIMER. NOTE: BACK ROOM AREA WALLS TO BE PAINTED TO A MINIMUM OF 14' ABOVE FINISHED FLOOR. PRIMER (IF NEEDED): SHERWIN-WILLIAMS PROGREEN 200 INTERIOR LATEX PRIMER, B28W600 (APPLIED @ 4 MILS WET; 1.5 MILS DRY), OR BENJAMIN MOORE - NO PRIMER REQUIRED. 1ST & 2ND COATS: SHERWIN-WILLIAMS PROGREEN 200 INTERIOR LATEX EG-SHEL, B20W651 SERIES (APPLIED @ 4 MILS WET; 1.7 MILS DRY), OR BENJAMIN MOORE - AURA EGGSHELL, PRODUCT 524 (APPLIED @ 3.8 MILS WET: 1.8 MILS DRY) - USE AT KNEE-WALL AND KNEE-WALL TRIM: ONE FINISH COAT OVER AN EXISTING FINISH OR PRIMER. PRIMER (IF NEEDED): SHERWIN-WILLIAMS PREPRITE BONDING PRIMER, B51W50 (APPLIED @ 4 MILS WET; 1.4 MILS DRY) OR BENJAMIN MOORE - NO PRIMER REQUIRED. 1ST COAT: SHERWIN-WILLIAMS PROGREEN 200 INTERIOR LATEX EG-SHEL, B20W651 SERIES (APPLIED @ 4 MILS WET; 1.7 MILS DRY), OR BENJAMIN MOORE - AURA EGGSHELL, PRODUCT 524 (APPLIED @ 3.8 MILS WET: 1.8 MILS DRY) - USE AT INTERIOR PLYWOOD SURFACES AND INTERIOR MASONRY SURFACES: TWO FINISH COATS OVER AN EXISTING FINISH OR PRIMER. PRIMER (IF NEEDED): SHERWIN-WILLIAMS PROGREEN 200 INTERIOR LATEX PRIMER, B28W600 (APPLIED @ 4 MILS WET; 1.5 MILS DRY), OR BENJAMIN MOORE NO PRIMER REQUIRED. 1ST & 2ND COATS: SHERWIN-WILLIAMS PROGREEN 200 INTERIOR LATEX EG-SHEL, B20W651 SERIES (APPLIED @ 4 MILS WET; 1.4 MILS DRY), OR BENJAMIN MOORE - AURA EGGSHELL, PRODUCT 524 (APPLIED @ 3.8 MILS WET: 1.8 MILS DRY) PAINT PT-1 AT SIDE WALLS AND PT-2 ON FRONT AND REAR WALLS OF SALES AREA FINISH & PAINT NOTES CS-1: CONCRETE SEALER - SHERWIN WILLIAMS SEAL-KRETE WATER-PROOFING CLEAR SEALER #151-1633. RF-1: SEAMLESS RESINOUS FLOOR - NOT USED REMARKS C "COMPANY NAME" 20XX ALL RIGHTS RESERVED EXIST. EXIST. 4. GRAB BARS (GB-2): EXPOSED MOUNTING, 1-1/2 INCH DIAMETER, STAINLESS STEEL, SATIN FINISH, WITH PROPER TYPE OF ANCHOR AND PLATE FOR CONSTRUCTION CONDITIONS AND NORMALLY ANTICIPATED LOADS. BOBRICK WASHROOM EQUIPMENT, INC.: NO. B-6106 SERIES OR EQUAL. FINISH FRONT ENTRY GLASS AND GLAZING PROVIDE GLASS LITES BY PPG INDUSTRIES OR EQUAL. WHERE FLOAT GLASS IS INDICATED, PROVIDE ANNEALED FLOAT GLASS. WHERE FULLY TEMPERED GLASS IS INDICATED, PROVIDE KIND FT HEAT-TREATED FLOAT GLASS. WHERE INSULATED GLASS IS INDICATED, PROVIDE LOW-E INSULATED GLASS. FOR WINDBORNE-DEBRIS-IMPACT RESISTANCE REGIONS (WIND ZONE 1,2,3, OR 4) AS DEFINED BY THE IBC, PROVIDE EXTERIOR GLAZING THAT PASSES BASIC PROTECTION TESTING REQUIREMENTS IN ASTM E1996. WHERE TRANSPARENT MIRROR IS INDICATED, PROVIDE FULLY TEMPERED, SCRATCH AND ABRASION RESISTANT, PYROLYTIC SURFACE COATING FORMED BY CHEMICAL VAPOR DEPOSITION. GYPSUM BOARD PRODUCTS BY USG CORPORATION OR EQUAL. INTERIOR WALL TYPE: 5/8" THICK TYPE X WITH LONG EDGES TAPERED. CEILING TYPE: MANUFACTURED TO HAVE MORE SAG RESISTANCE THAN REGULAR-TYPE GYPSUM BOARD. THICKNESS: 1/2 INCH THICK WITH LONG EDGES TAPERED. MATL. AUTO SLIDING JOINT SEALANTS PROVIDE JOINT SEALANTS, BACKINGS, AND OTHER RELATED MATERIALS THAT ARE COMPATIBLE WITH ONE ANOTHER AND WITH JOINT SUBSTRATES UNDER CONDITIONS OF SERVICE AND APPLICATION, AS DEMONSTRATED BY JOINT-SEALANT MANUFACTURER, BASED ON TESTING AND FIELD EXPERIENCE. WHERE SEALANTS ARE INDICATED FOR JOINTS THAT WILL COME IN REPEATED CONTACT WITH FOOD, PROVIDE PRODUCTS THAT COMPLY WITH21 CFR 177.2600 ALUMINUM ENTRANCES AND STOREFRONTS PRODUCTS BY KAWNEER NORTH AMERICA: TRIFAB V6 451T OR EQUAL. OLD CASTLE GLASS ENGINEERED PRODUCTS: GTC 451. TUBELITE: 14000 SERIES. UNITED STATES ALUMINUM: SERIES IT451. THERMALLY BROKEN 2 INCH SIGHTLINE BY 4-1/2 INCH DEPTH OR MATCH EXISTING. COLOR: CLEAR ANODIC FINISH OR MATCH EXISTING ALUMINUM STOREFRONT FINISH 100A THROUGH-PENETRATION FIRESTOP SYSTEMS PROVIDE PRODUCTS BY TREMCO FIRE PROTECTION SYSTEMS GROUP OR EQUAL PENETRATION FIRESTOPPING THAT IS PRODUCED AND INSTALLED TO RESIST SPREAD OF FIRE PER REQUIREMENTS INDICATED, RESIST PASSAGE OF SMOKE AND OTHER GASES, AND MAINTAIN ORIGINAL FIRE-RESISTANCE RATING OF CONSTRUCTION PENETRATED. STEEL DOORS AND FRAMES STANDARD FLUSH PANEL HOLLOW METAL DOORS AND METAL FRAMES BY STEELCRAFT OR EQUAL. MANUFACTURER'S STANDARD KRAFT-PAPER HONEYCOMB, POLYSTYRENE, POLYURETHANE, POLYISOCYANURATE, MINERAL-BOARD, OR VERTICAL STEEL-STIFFENER CORE AS SUITED TO DOOR TYPE. FIRE DOOR CORE TO PROVIDE FIRE-PROTECTION RATINGS INDICATED. INSULATED DOORS WITH R-VALUE OF NOT LESS THAN 12.3 DEGREES F PER SQUARE FOOT PER BTU SQUARED PER INCH. ANCHORS TO MATCH WALL TYPE MATL. WALLS 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. FLOOR PREPARATION - REPAIR EXISTING FLOOR SUCH THAT DEFECTS DO NOT TELEGRAPH THROUGH NEW FLOOR COVERING. USE ARMSTRONG, PORTLAND CEMENT BASED PATCHING MATERIAL (4,500 PSI MINIMUM). USE THE ARMSTRONG PRODUCT WHICH IS APPROPRIATE FOR THIS APPLICATION: S-183 FAST SETTING CEMENT BASED UNDERLAYMENT S-184 FAST SETTING CEMENT BASED PATCH AND SKIM COAT OR S-194 PATCH, UNDERLAYMENT AND EMBOSSING LEVELER EITHER w/ OR w/o THE S-195 UNDERLAYMENT ADDITIVE AS DEEMED NECESSARY. DO NOT USE GYPSUM BASED MATERIAL FOR FLOOR PATCH. SAVE-A-LOT HAS A STRATEGIC ACCOUNT AGREEMENT WITH ARMSTRONG WORLD INDUSTRIES INC, WHICH SECURES FAVORED PRICING FOR FLOORING MATERIALS USED ON SAVE-A-LOT PROJECTS. CONTACT YOUR LOCAL ARMSTRONG DISTRIBUTOR AND REQUEST SAVE-A-LOT/DEALS NATIONAL PRICING. CALL LISA CAVATAIO, ACCOUNT REPRESENTATIVE. TELEPHONE: 773 868 0270 CELL: 773 -882-0299 [email protected] IF YOU HAVE QUESTIONS. SAVE-A-LOT HAS A STRATEGIC ACCOUNT AGREEMENT WITH ARMSTRONG WORLD INDUSTRIES INC, WHICH SECURES FAVORED PRICING FOR ACOUSTICAL CEILING MATERIALS USED ON SAVE-A-LOT PROJECTS. CALL BARRY R BURNETT, COMMERCIAL STRATEGIC ACCOUNTS MANAGER-MIDWEST. PHONE: 1-877-ARMSTRONG, OPTION 8, EXT. 8091 OFFICE: 513-398-9448 [email protected] FOR PRICING INFORMATION AND TO PLACE ORDERS. DELIVER FOUR (4) ADDITIONAL CARTONS OF FLOOR TILE AND (4) CARTONS OF CEILING TILE, IN THE SAME RUN AS USED IN FIELD, TO THE STORE MANAGER AT THE COMPLETION OF THE PROJECT FOR ATTIC STOCK. REMOVE SURFACE IMPERFECTIONS AND POWER-WASH THE FLOOR PRIOR TO APPLYING THE CONCRETE SEALER (CS-1). SAVE-A-LOT HAS A STRATEGIC ACCOUNT AGREEMENT WITH SHERWIN WILLIAMS PAINT COMPANY AND BENJAMIN MOORE PAINTS, WHICH SECURES FAVORED PRICING FOR MATERIALS USED ON SAVE-A-LOT PROJECTS. ALL PRODUCTS SPECIFIED - IN BOTH COLOR AND NAME - ARE OF MANUFACTURE FROM THE SHERWIN WILLIAMS PAINT COMPANY AND BENJAMIN MOORE PAINTS. FOR ANY CONCERNS OR QUESTIONS REGARDING THESE SPECIFICATIONS, PLEASE CONTACT SHERWIN WILLIAMS ARCHITECTURAL ACCOUNT EXECUTIVE BRIAN BENSON AT (303) 794-8472 OR BENJAMIN MOORE NATIONAL ACCOUNT DEPARTMENT AT (877) 626-5676 (SAVE-A-LOT IS NATIONAL ACCOUNT NA - 060.) SPECIFIED PAINT PRIME AND FINISH COATS ARE IN ADDITION TO SHOP PRIMING AND SURFACE TREATMENTS PROVIDED BY OTHER TRADES PRIOR TO PAINTING. ALL SURFACE PREPARATION MUST BE DONE IN ACCORDANCE WITH THE MANUFACTURER'S PRODUCT DATA LITERATURE AND LABEL INSTRUCTIONS. ALL SURFACES SHOULD BE CLEAN, DRY AND FREE OF ANY DIRT OR ADDITIONAL FOREIGN CONTAMINATES. FOR ALL REPAINT AND REMODEL SITUATIONS THE PRIME COATS MAY BE DELETED UNLESS COATING A BARE SURFACE. FOLLOW MANUFACTURERS' RECOMMENDED SURFACE PREPARATION. SCRAPE AND REPAINT ALL EXPOSED EXTERIOR STRUCTURAL COMPONENTS WITH A RUST INHIBITING COATING. VERIFY WITH SAVE-A-LOT PROJECT MANAGER. TOUCH-UP EXTERIOR PAINT AT NEW AND CLOSED OPENINGS CONSISTENT WITH ADJACENT SURFACES. EXTEND FLOOR TILE 4' INTO BACK ROOM AT DOORWAYS. PROVIDE 1/8" DIAMOND PLATE TRANSITION ABUTTING THE TILE EDGE AND FLUSH W/ TILE SURFACE. FASTEN TRANSITION PLATE w/ 1/4" DRIVE PINS. PERIMETER WALLS IN SALES AREA, BACK ROOM AREA, OFFICE AND BREAK ROOM SHALL BE PAINTED (PT-1): BACK ROOM AREA WALLS TO BE PAINTED TO A MINIMUM OF 14'-0" A.F.F. KNEE WALL AND KNEE WALL TRIM SHALL BE PAINTED (PT-1). INTERIOR COLUMNS SHALL BE PAINTED (PT-1). DOORS AND FRAMES FOR THE OFFICE, BREAK ROOM, REST ROOMS, COILING OVERHEAD DOORS AND EXIT DOORS SHALL BE PAINTED (PT-3). FRAMES FOR THE UNI-FLEX DOORS SHALL BE PAINTED (PT-3). CONTRACTOR TO PROVIDE FOR RESILIENT FLOORING TO BE STRIPPED, SEALED, WAXED (4 COATS), AND BUFFED. PERFORM FINAL BUFFING THE NIGHT PRIOR TO OPENING. PAINT CEILING DIFFUSERS TO MATCH THE CEILING. PT-2: SHERWIN WILLIAMS - CUSTOM: REAL RED TINT BASE 640398673 (ONE GALLON) Y1- YELLOW 4 OZ 17/32 W1- WHITE 0 OZ 12/32 - USE AT GYPSUM DRYWALL (SALES AREA FRONT AND BACK WALLS): TWO FINISH COATS OVER AN EXISTING FINISH OR PRIMER. PRIMER (IF NEEDED): SHERWIN-WILLIAMS PROGREEN 200 INTERIOR LATEX PRIMER, GRAY P-2 DRYWALL PRIMER B28W600 (APPLIED @ 4 MILS WET; 1.5 MILS DRY), 1ST & 2ND COATS: SHERWIN-WILLIAMS DURATION HOME INTERIOR ACRYLIC LATEX, SATIN FINISH (APPLIED @ 4 MILS WET; 1.7 MILS DRY), PT-3: SHERWIN WILLIAMS SW 6081 DOWN HOME,OR BENJAMIN MOORE 1028 SPANISH BROWN - USE AT DOORS AND FRAMES FOR THE OFFICE, BREAK ROOM, REST ROOMS, COILING OVERHEAD DOORS, EXITS AND UNI-FLEX DOORS: TWO FINISH COATS OVER AN EXISTING FINISH OR A PRIMER. PRIMER (IF NEEDED): SHERWIN-WILLIAMS PRO-CRYL UNIVERSAL METAL PRIMER, B66 SERIES (MIN. APPLICATION @ 5.0 MILS WET; 2.0 MILS DRY), OR BENJAMIN MOORE - NO PRIMER REQUIRED - JUST LIGHTLY SCUFF. 1ST & 2ND COATS SHERWIN-WILLIAMS PROCLASSIC XP INTERIOR ALKYD SEMI-GLOSS ENAMEL B34W551 SERIES (APPLIED @ 4.0 MILS WET; 3.7 MILS DRY), OR BENJAMIN MOORE - AURA SATIN, PRODUCT 526 (APPLIED @ 3.8 MILS WET: 1.5 MILS DRY) PT-4: SHERWIN WILLIAMS SW 7006 EXTRA WHITE OR BENJAMIN MOORE -01 WHITE - USE AT CEILING GRID, LIGHT FIXTURES AND DIFFUSERS IN SALES AREA: ONE FINISH COAT OVER EXISTING FINISH OR PRIMER. PRIMER (IF NEEDED): SHERWIN WILLIAMS PREPRITE PROBLOCK INTERIOR LATEX PRIMER/SEALER, B28W200 (APPLIED @ 4 MILS WET; 1.4 MILS DRY) FOR STAINED OR GLOSSY AREAS ONLY OR BENJAMIN MOORE FRESH START ACRYLIC PRIMER, PRODUCT 023 (APPLIED @ 3.8 MILS WET; 1.1 MILS DRY.) FOR STAINED OR GLOSSY AREAS ONLY. 1ST COAT: SHERWIN WILLIAMS PROGREEN 200 INTERIOR LATEX SEMI-GLOSS B31W600 SERIES (APPLIED @ 4 MILS WET, 1.4 MILS DRY) OR BENJAMIN MOORE SUPER SPEC SEMI-GLOSS, PRODUCT 276 (APPLIED @ 3.8 MILS WET; 1.2 MILS DRY) PT-5: USE AT EXPOSED CEILING DECK IN SALES FLOOR AND VESTIBULE (NEW CONSTRUCTION) AND/OR EXISTING/NEW FOIL-FACED DUCT BOARD AND FLEX DUCT: ONE FINISH COAT EVENLY SPRAYED OVER EXISTING FINISH OR PRIMER. APPLY PER RECOMMENDATIONS IN SPECIFICATIONS. PRIMER (IF NEEDED): SHERWIN WILLIAMS PRO-CRYL UNIVERSAL METAL PRIMER, B66 SERIES (MIN. APPLICATION @5.0 MILS WET; 2.0 MILS DRY), OR BENJAMIN MOORE ACRYLIC METAL PRIMER, PRODUCT M04 (APPLIED @2.9-5.9 MILS WET; 1.5-2.5MILS DRY.) 1ST COAT: SHERWIN WILLIAMS WATERBORNE ACRYLIC DRYFALL B42W42 (MINIMUM APPLICATION @ 7 MILS WET, 3.0 MILS DRY) OR BENJAMIN MOORE SWEEP UP LATEX FLAT, PRODUCT M53 (APPLIED @ 3.8-6.2 MILS WET; 1.5-2.5 MILS DRY) ALEXANDER CITY, AL TYPE FLOOR 08/23/10 FIN. ROOM NAME DATE: MATL. ROOM NO. 1612 MILLS SQUARE TYPE REMARKS PRELIMINARY NOT FOR BID OR CONSTRUCTION FIN. KEY NOTES GAT MATL. HARDWARE CHECKED: FRAME BY: DOOR DATE: EXIST /NEW DESCRIPTION: LOCATION REV. NUMBER: DOOR SIZE CERTIFICATION: ROOF ACCESSORIES PROVIDE PRODUCTS BY ROOF PRODUCTS, INC. OR EQUAL REINFORCED ROOF-CURB AND EQUIPMENT SUPPORT UNITS CAPABLE OF SUPPORTING SUPERIMPOSED LIVE AND DEAD LOADS, INCLUDING EQUIPMENT LOADS AND OTHER CONSTRUCTION INDICATED ON DRAWINGS MINIMUM HEIGHT OF 12 INCHES UNLESS OTHERWISE INDICATED. MANUFACTURER'S STANDARD COUNTERFLASHING DOOR NO. (* SEE GENERAL & KEY NOTES BELOW) BLM EXTERIOR INSULATION AND FINISH SYSTEM (EIFS) DRYVIT SYSTEMS, INC.: OUTSULATION SYSTEM OR EQUAL BACKER BOARD: 5/8" FIRESTOP TYPE X DENS-GLASS GOLD GYPSUM SHEATHING, BY GEORGIA PACIFIC MOLDED, RIGID CELLULAR POLYSTYRENE BOARD INSULATION ROOM FINISH SCHEDULE DOOR SCHEDULE & NOTES DRAWN: ARCHITECTURAL SPECIFICATIONS STORE NUMBER PROJECT NUMBER 03510-01 SHEET TITLE DOOR AND ROOM FINISH SCHEDULES AND NOTES SHEET NUMBER A-5 BY: NOT USED 3/16" PLATE x WALL WIDTH x LENGTH OF OPENING PLUS 4" BEARING EACH END - PROVIDE 1/2" dia x 4" HEADED STUDS @ 2'-0" o/c - PLATE MAY BE (2) PIECES & BUTT WELD DOOR HEAD 1'-0" 2" NEW CEILING DOOR AND TRACK EXISTING CONCRETE FOOTING TO REMAIN 8" SILICONE CAULK AT WALL NEW DOOR SILL AT EXIST WALL GROUT JAMBS SOLID EACH SIDE OF DOOR OPENING FULL HEIGHT #4 DOWELS @ 16" o/c, ALL SIDES SCALE: 3/4" = 1'-0" USE FOR NEW OPENING IN NEW MASONRY OR EXISTING WALLS 6'-0" TO 12'-0" IN LENGTH W8x24 WITH 5/16" x 11 1/2" BOTTOM PLATE CONTINUOUS L-3 EXISTING MASONRY WALL BEYOND NEW DOORS #4 DOWELS x 1'-0" @ 16" o/c DRILL INTO EXIST CONC 12" EXIST CONCRETE FLR SLAB TO REMAIN 12" FIN FLR EL USE FOR NEW OPENING IN EXISTING MASONRY WALLS NOT TO EXCEED 5'-4" NOTE; USE ONLY IN CLIMATE NOT SUSCEPTIBLE TO SIGNIFICANT FREEZE/THAW CYCLES 12" 4" CONCRETE SLAB, REINF w/#4 @ 16" o/c E.W. w/2" MINIMUM CLEAR COVER BOTTOM EXISTING CMU WALL TO REMAIN DOOR JAMB L-2 NEW #3 DOWELS @ 2'-0" o/c EACH SIDE AND STAGGERED DRILL AND EPOXY MINIMUM 4" INTO EXISTING CONCRETE EACH SIDE 5 NEW BOLLARD TYP. EACH SIDE, SEE ARCH (2)-L's-4x4x5/16 w/5/16" CONT BOTTOM PLATE WIDTH TO SUPPORT BLOCK BEAR ANGLES MINIMUM 4" EACH END (3)-L's-4x4x5/16 w/5/16" CONT BOTTOM PLATE WIDTH TO SUPPORT BLOCK AND BRICK - BEAR ANGLES MINIMUM 4" EACH END L-4 (+)0'-0" 1/4" 3" @ 12" o/c 1/4" 3" @ 12" o/c USE FOR NEW OPENING IN EXISTING MASONRY WALLS NOT TO EXCEED 5'-4" w/ BRICK T/FND WALL (-)0'-8" 8" MSNRY WALL #4 DOWELS @ 16" o/c TFE GROUT DOWELS SOLID IN FND WALL NON-FROST SUSCEPTIBLE FILL FROM BOTTOM FTG ELEV TO SLAB BRG 16" 8" MIN 3" @ 12" o/c 3/16" BOLT STEEL LINTELS TO MASONRY w/(2)-5/8" dia HILTI KWIK BOLT 3 EXPANSION ANCHORS. 3. FILL LINTEL BLOCK AND BOND BEAM LINTELS WITH GROUT. 4. BEAR LINTEL BLOCK AND BOND BEAM LINTELS 8" MINIMUM ON GROUTED JAMBS. 5. EXTEND BOTTOM PLATE FOR STEEL LINTELS THE WIDTH OF THE OPENING LESS 1/4" AT EACH JAMB, UNO. 6. STEEL LINTELS TO BEAR 8" ON 3/8" x 10"x 10" WIDE BEARING PLATES. MIN NEW 4" CONCRETE FLOOR SLAB NOT USED 5/8" dia PAINTED STEEL INFILL RODS POLYUREA JOINT FILLER T/CONC PAD EL VARIES 12" 4" O.C. TYP. MC-10x8.4 INTERMEDIATE CHANNEL EXISTING CONCRETE FLOOR SLAB JOINT FILLER STEEL PLATE LANDING WITH MC-10x8.4 STEEL PERIMETER CHANNELS ANCHORED TO WALLS WITH 5/8" dia HILTI HLC SLEEVE ANCHORS AT 16" o/c (MINIMUM OF THREE ANCHORS) NOTE: PAINT ALL EXPOSED STEEL VERIFY T/EX. FND. WALL (-)0'-8" TO REMAIN EXISTING FOUNDATION WALL EXISTING CONCRETE PAD TO REMAIN STEEL PIPE HANDRAIL EACH SIDE, TYP 7 SEE 7/S-1 FOR HANDRAIL TYPICAL 4" CONCRETE SLAB REINF w/#4 @ 16" o/c E.W. w/2" MINIMUM CLEAR COVER BOTTOM PROVIDE ADDITIONAL W12x26 ONLY IF GUARD RAIL IS REQUIRED NEW W12x26 EACH SIDE OF NEW CONDENSER FRAMES 1/4" TOP SLAB (+)0'-0" TOP WALL (-)0'-8" #4 DOWELS @ 16" o/c 24" 8" CONCRETE WALL - DO- REINF 8" 2" @ 6" o/c TYP ALL NOTE: PLACE ONE CURB FOR NEW HVAC UNITS ON AN EXISTING BEAM OR GIRDER LINE NOT USED NEW CONTINUOUS EQUIPMENT CURB MINIMUM (2)-2x8's REFERENCE SHEET M-1 FOR NEW HVAC REQUIREMENTS NEW WOOD BLOCKING SHIM AT JOIST TOP CHORD ONLY REMOVE AND REPLACE TO EXISTING CONDITION AFTER STAIR INSTALLATION SECURE NEW CURB TO SHIM 8" CONCRETE WALL, REINF w/#4 @ 16" o/c VERT & #4 @ 12" o/c HORIZ - DOWELS TO MATCH WALL VERTS 1'-8" WIDE x 1'-0 DEEP CONTINUOUS CONCRETE FOOTING, REINF w/(2)-#4 BOTTOM SCALE: 3/4" = 1'-0" EXTERIOR CONCRETE STAIR EXISTING STEEL JOIST NOTE: JOIST CHORDS ARE NOT DESIGNED FOR CONCENTRATED LOADS. EITHER PLACE LOADS AT JOIST PANEL POINTS OR ADD EXTRA WEB MEMBER FROM POINT OF LOAD TO NEAREST JOIST PANEL POINT ON OPPOSITE CHORD EXISTING BEAM OR GIRDER NEW (2)-L's 2x2x3/16" EXTRA WEB MEMBER AT CONCENTRATED LOADS FIELD WELD EXTRA WEB MEMBER @ CONCENTRATED LOADS ON JOIST TOP CHORD 2 EXTRA WEB MEMBER AT JOIST SCALE: 3/4" = 1'-0" EXISTING STEEL JOIST AND ROOF DECK REINF EXISTING STEEL BEAM w/ (4) L's-2 1/2x2 1/2x1/4 12'-0" LONG CENTERED @ BEAM MID-SPAN @ EACH EXISTING BEAM SUPPORTING A NEW CONDENSER EXISTING STEEL BEAM REINF AS SHOWN CONCRETE DOCK SLAB REINF w/#4 @ 16" o/c E.W. OR FIBERS 5/16"x 1 1/2" EXISTING MASONRY WALLS TO REMAIN SCALE: 3/4" = 1'-0" EXISTING ROOF DECK ANGLES 8 ROOF OPENING FRAME 1/8" NON-FROST SUSCEPTIBLE FILL 24" TFE SEE PLAN 1 IN 24" #4 DOWELS @ 16" o/c SHOP FABRICATE IN ACCORDANCE WITH JOIST SPACING, VERIFY IN FIELD OR PROVIDE 20' STOCK LENGTHS AND FIELD CUT EXISTING STEEL JOIST TOP CHORD M NEW 5" dia STD PIPE COLUMNS w/1/2"x 8" x 11" CAP AND BOTTOM PLATES & (4)-5/8" dia HILTI KWIK BOLT 3 EXPANSION ANCHORS w/MIN 4" EMBEDMENT IN GROUTED MASONRY EXTEND STEEL COLUMN TO TOP MASONRY WALL OR STEEL BEAM TOP FLANGE CONCRETE STAIRS, REINF w/#4 @ 16" o/c E.W. & #4 NOSING BARS, TYP 2" CLR (1) W8x10 @ CONDENSER MID-LENGTH w/(1) BAY 1/2" dia ROD X-BRACING AT BEAM MID-DEPTH SEE ARCH CL 2" 4" R NOT TO EXCEED 36'-0" SCALE: 1/2" = 1'-0" ALL NEW FRAMING ANGLES SHALL BE 3x3x1/4 NOTE: VERIFY OPENING SIZES AND PROVIDE FRAMES AT ALL ROOF OPENINGS LARGER THAN 12" BOTH WAYS 12"dia x 30" DEEP CONCRETE PIERS - (2) SUCH EXTERIOR STEEL STAIR EXISTING STEEL JOIST TOP CHORD ONE OR BOTH MEMBERS MAY BE ELIMINATED DEPENDING ON OPENING WIDTH - FIELD CUT AS REQUIRED FROM STOCK LENGTHS WELD ALL 3x3 ANGLE CONNECTIONS MC-10x8.4 CHANNEL STRINGER WELD TO LANDING SEE ARCH SCALE: 3/4" = 1'-0" TYP ALL 3/16" NEW L-3x3x1/4 x 0'-6" LONG (4) SUCH 11" 12" (2) - 3" dia STEEL PIPE SUPPORTS WITH 6" x 6" x 1/4" STEEL BASE PLATE ON 1" MINIMUM LEVELING GROUT ANCHOR w/(4)-1/2"dia COILING DOOR AT SILL 1/8" STEEL TREAD NOTE;CONTRACTOR TO CHOOSE LEAST EXPENSIVE OF DETAILS 7 & 8 FOR STAIR SELECTION DOWEL NEW SLAB TO EXISTING w/ 1/2" dia x 16" REBAR @ 12" o/c SCALE: 3/4" = 1'-0" NEW STOOP @ EXIST WALL 3'-0" MIN 6 8" 1" NOTE: ANGLE NOT REQUIRED WHEN EXISTING SLAB IS AT DOOR SILL HEIGHT 1'-8" 2. 3'-0" 1" NEW PLATE 3/16" x 1'-2" x 6'-0" WIDE ANCHORED INTO CONC SLAB w/ (2)-1/2" dia x 2 1/2" HEADED STUDS @ 12" o/c WELDED TO BOTTOM OF PLATE VERIFY NEW L-4x4x5/16 w/ 3/8" dia x 4" HEADED STUDS @ 8" o/c EMBEDDED INTO CONC @ DOOR WIDTH ONLY 12 SEE ARCHITECTURAL FOR MASONRY OPENING WIDTHS. NEW DOOR, SEE ARCH 2" CLR TYP 1'-8" WIDE x 1'-0" DEEP CONC FTG w/(2)-#4 BOTT CONT NEW 2500 psi CONCRETE FLOOR PATCH 1. EXISTING CONCRETE FOOTING TO REMAIN NOTE; USE ONLY IN CLIMATE SUSCEPTIBLE TO SIGNIFICANT FREEZE/THAW CYCLES SEE PLAN 1'-0" LINTEL NOTES EXIST FOUNDATION WALL TO REMAIN SHALL NOT EXCEED 6'-0" COILING DOOR HEAD & JAMB #4 DOWELS x 1'-0" @ 16" o/c DRILL INTO EXIST CONC VARIES 11 SCALE: 3/4" = 1'-0" SAW CUT AND FILL w/JOINT FILLER PER MANUFACTURERS RECOMMENDATIONS EXISTING ROOF DECK NEW (2)-L's 2x2x3/16 EXTRA WEB MEMBER AT CONCENTRATED LOADS FIELD WELD EXISTING STEEL JOIST 1/8" 3" NEW CONDENSER SUPPORT OPTIONS: NOTE: CONTROL JOINT SPACING NOT TO EXCEED 15'-0" o/c COVER FIN FLR EL 5" MIN. NEW CONDENSER SUPPORT EXISTING FLOOR SLAB NEW (2)-L's 3x3x1/4 w/DOUBLE NUT OR COMPARABLE UNI-STRUT NEW 1/2"dia HANGER ROD w/DOUBLE NUT TOP AND BOTTOM (IN ORDER OF PREFERENCE) A. ON GRADE AT REAR OF EXISTING BUILDING IF AVAILABLE. B. ON EXISTING SUPPORT FRAMING PREVIOUSLY ABANDONED. C. ON EXISTING ROOF PER THIS DETAIL. 13 NOTE: JOIST CHORDS ARE NOT DESIGNED FOR CONCENTRATED LOADS. EITHER PLACE LOADS AT JOIST PANEL POINTS OR ADD EXTRA WEB MEMBER FROM POINT OF LOAD TO NEAREST JOIST PANEL POINT ON OPPOSITE CHORD 6" NOT USED NOTE: LOCATE NEW CONDENSER UNITS A MINIMUM OF 10'-0" FROM ROOF EDGE OR PROVIDE NEW GUARD RAIL. SCALE: 3/4" = 1'-0" 9 COMPACT EXISTING SUBGRADE PRIOR TO CONCRETE POUR EXTER CONC PAD CONTROL JT SCALE: 1 1/2" = 1'-0" @ HANGER ROD EXTRA WEB MEMBER @ CONCENTRATED LOADS ON JOIST BOTTOM CHORD 3 EXTRA WEB MEMBER @ JSTS NOTE: REPLACE DAMAGED VAPOR RETARDER IF PRESENT. LAP MINIMUM 6" OVER EXISTING EDGES CONCRETE FLOOR SLAB PATCH, SEE 4/S-1 EXISTING BITUMINOUS PAVING TO REMAIN (+)0'-0" CONCRETE PAD - REINF w/#4 @ 16" o/c E.W. OR FIBERS 8" NEW CONCRETE FLOOR SLAB PATCH, REINF w/#3 @ 16" o/c E.W. OR SYNTHETIC FIBERS REINFORCE ONLY AT WIDTHS EXCEEDING 2'-6" EXISTING SLAB 3" 6" MIN TYP NOT USED NOTE: NEW CONCRETE STRENGTH 2500 psi @ 28 DAYS NEW FLOOR PATCH EXISTING SLAB SCALE: 3/4" = 1'-0" STRUCTURAL FILL IN FLOOR ACCESS PIT AND COVER, VERIFY SIZES REQUIRED COMPACT EXISTING SUBGRADE PRIOR TO CONCRETE POUR PVC PIPE, SEE PLAN 14 TYPICAL REFRIGERATION PIT SCALE: 3/4" = 1'-0" 10 EXTER CONC PAD AT EDGE SCALE: 1 1/2" = 1'-0" SLUSH NEW CONCRETE UNDER EXISTING SLAB REPLACE DISTURBED SOIL WITH CONCRETE 4 FLOOR SLAB PATCH NEW 1/2" dia DOWELS x 16" LONG @ 24" o/c - DRILL AND EPOXY INTO EXISTING FLOOR SLAB - STAGGER SIDES - NOT REQUIRED AT WIDTHS LESS THAN 16" SCALE: 1 1/2" = 1'-0" C "COMPANY NAME" 20XX ALL RIGHTS RESERVED COILING DOOR ANCHORED TO MASONRY BY OTHERS NEW BENT PLATE 1 1/2" x 12" x 3/16" x FULL DOOR HEIGHT w/ 1/2" dia x 4" HEADED STUDS @ 2'-0" o/c COORDINATE HEIGHT WITH DOOR OPENING AND DOOR HARDWARE - PAINT BY GC EXISTING FOUNDATION WALL TO REMAIN GROUT DOWELS SOLID IN EXISTING FOUNDATION WALL TOP OPENING SEE ARCH 1.0 1.0 MPH PSF 1.0 PSF PSF I %g %g D FOUNDATION/SOILS NOTES 22. FINISH FLOOR ELEVATION ASSUMED ---------------------------------------------------------- (+) 0'-0" 23. SOIL BEARING CAPACITY ASSUMED ------------------------------------------------------------ 2000 PSF 24. FOOTING ELEVATIONS SHOWN ARE THE TOP OF FOOTING ELEVATIONS (T.F.E.) REFERENCED FROM FINISHED FLOOR ELEVATION. 25. CONSTRUCT FOOTINGS TO COMPLEMENT CENTERING OF WALLS AND COLUMNS. 26. BRACE FOUNDATION WALLS AND RETAINING WALLS BEFORE BACKFILLING AND COMPACTION OPERATIONS. 27. CROSS REFERENCE STRUCTURAL AND ARCHITECTURAL DRAWINGS TO ASSURE PROPER DIMENSIONING AND PLACEMENT OF ANCHOR BOLTS, INSERTS AND OTHER RELATED EMBEDMENTS. 28. COORDINATE FLOOR SLAB CONTROL JOINT AND CONSTRUCTION JOINT LAYOUT WITH FLOOR FINISH PLAN. ALIGN CONCRETE JOINTS WITH FLOOR FINISH JOINTS. 29. DROP FOOTINGS BELOW UTILITIES WHERE SUBSEQUENT EXCAVATIONS WILL UNDERMINE FOOTINGS. VERIFY LOCATIONS. 30. PROVIDE 1" OVERSIZED SLEEVE FOR PIPES PENETRATING FOUNDATION WALLS. 31. SEE ARCHITECTURAL DRAWINGS FOR FOUNDATION WALL INSULATION. SITE CONCRETE NOTES 32. ALL EXTERIOR CONCRETE TO BE MINIMUM 4000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. PROVIDE AIR-ENTRAINMENT AT 4 PERCENT - 6 PERCENT AND WATER/CEMENT RATIO NOT TO EXCEED 0.45. HRWR ADMIXTURES ARE ACCEPTABLE WITHIN MANUFACTURER'S RECOMMENDED DOSAGE AND MAXIMUM SLUMP OF 5". 33. ALL REINFORCING BARS TO BE Fy = 60 KSI 34. FOR CONCRETE COVER AND BAR LAPS REFERENCE - BUILDING SHELL CONCRETE. BUILDING SHELL CONCRETE NOTES 35. ALL BUILDING SHELL CONCRETE, EXCEPT PATCHING OF FLOOR SLABS, TO BE MINIMUM 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS WITH WATER/CEMENT RATIO NOT TO EXCEED 0.50. HRWR ADMIXTURES ARE ACCEPTABLE WITHIN MANUFACTURER'S RECOMMENDED DOSAGE AND MAXIMUM SLUMP OF 5". 36. FOR FULL DEPTH PATCHING OF FLOOR SLABS, CONCRETE STRENGTH TO BE 2500 PSI. 37. ALL REINFORCING BARS TO BE Fy = 60 KSI. 38. MINIMUM CONCRETE COVER FOR REINFORCING STEEL: a. CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH ----------------------3" b. EXPOSED TO EARTH OR WEATHER: No. 6 BAR & LARGER ----------2" No. 5 BAR & SMALLER --------- 1 1/2" c. NOT EXPOSED TO EARTH OR WEATHER: SLABS, WALL, JOISTS ---------1" BEAMS & COLUMNS --------- --------- 1 1/2" 39. SPLICED REINFORCING LAPS: NO. 6 BAR & SMALLER -------------38 BAR DIAMETERS NO. 7 BAR & LARGER ---------------48 BAR DIAMETERS NOTE: MECHANICAL AND WELDED SPLICES ARE PERMITTED. 40. PROVIDE CORNER BARS TO MATCH SIZE & SPACING OF HORIZONTAL REINFORCING AT INTERSECTING REINFORCED CONCRETE WALLS. 41. OPENINGS IN STRUCTURAL MEMBERS NOT SHOWN ON CONSTRUCTION DOCUMENTS AND CONSTRUCTION JOINTS IN STRUCTURAL MEMBERS PERPENDICULAR TO MAIN FLEXURAL REINFORCING ARE NOT PERMITTED WITHOUT WRITTEN APPROVAL OF S.E.R.. 42. REPAIR ALL CRACKS, HOLES AND OPENINGS THAT WOULD DELAY PERMITTING OR HEALTH DEPARTMENT APPROVALS. USE APPROPRIATE ARDEX MATERIALS OR EQUAL. MASONRY NOTES 43. HOLLOW CMU ASTM C-90 UNIT STRENGTH -------------------------------------------------- 1900 PSI 44. ALL REINFORCING BARS TO BE ---------------------------------------------------------------- Fy = 60 KSI 45. MORTAR ----------------------------------------------------------------------------------------TYPE 'S' 46. GROUT ------------------------------------------------------------------------------------------2000 PSI 47. SPLICED REINFORCING LAPS: NO. 4 BAR -------------------------------------------28" NO. 5 BAR -------------------------------------------36" NO. 6 BAR -------------------------------------------48" NOTE: MECHANICAL AND WELDED SPLICES ARE PERMITTED. 48. REFER TO ACI 530 AND ACI 530.1 FOR MINIMUM CONSTRUCTION REQUIREMENTS. 49. REFERENCE LINTEL SCHEDULE FOR MASONRY LINTEL REQUIREMENTS. 50. CLOSE OPENINGS IN EXISTING MASONRY WALLS NOTED ON DRAWINGS WITH MASONRY UNITS MATCHING EXISTING CONSTRUCTION. STRUCTURAL STEEL NOTES 51. WIDE FLANGE BEAMS -------------------------------------------------------------------------- Fy = 50 ksi 52. CHANNELS, ANGLES, PLATES ----------------------------------------------------------------- Fy = 36 ksi 53. HIGH STRENGTH BOLTS ---------------------------- ASTM A-325 ----------------------------'N' TYPE 54. ANCHOR RODS -------------------------------------- ASTM A-307 ---------------------------- Fy = 36 ksi 55. SQUARE OR RECTANGULAR HSS ------------------- ASTM A-500 gr 'B' -------------------- Fy = 46 ksi 56. STEEL PIPE ------------------------------------------ ASTM A-53 ----------------------------- Fy = 35 ksi 57. STEEL ROOF DECKING ----------------------------- GRADE 33 ------------------------------ Fy = 33 ksi 58. STEEL FLOOR FORM DECKING --------------------- GRADE 80 ------------------------------ Fy = 80 ksi 59. STEEL STUDS --------------------------------------- ASTM A1003 --------------------------- Fy = 33 ksi 60. EXPANSION ANCHORS: a. CONCRETE: HILTI HSL OR HSL-3 HEAVY DUTY SLEEVE ANCHOR OR HILTI KWIK BOLT 3 OR KWIK BOLT TZ EXPANSION ANCHOR (HIGH SEISMIC). b. HOLLOW CORE CONCRETE: HILTI HDI-P DROP-IN ANCHORS c. GROUT FILLED CONCRETE BLOCK: HILTI KWIK BOLT 3 OR HILTI KWIK BOLT TZ EXPANSION ANCHOR d. UNGROUTED CONCRETE BLOCK: HILTI HLC SLEEVE ANCHOR 61. ALL WELDING WILL BE BY "AWS" CERTIFIED WELDERS. WELDERS SHALL BE CERTIFIED FOR POSITION REQUIRED BY THE WORK. 62. DESIGN BEAM CONNECTIONS IN ACCORDANCE WITH THE NINTH EDITION OF AISC MANUAL OF STEEL CONSTRUCTION, FOR MAXIMUM BEAM END REACTION. 63. FIELD ALTERATIONS OF STRUCTURAL MEMBERS ARE NOT PERMITTED WITHOUT WRITTEN APPROVAL OF STRUCTURAL ENGINEER OF RECORD. 64. BEAR STEEL BEAMS AND STEEL LINTELS A MINIMUM OF 8" ON CMU ELEMENTS. GROUT CELLS THE WIDTH OF THE WALL x 16 INCHES LONG FROM FOOTING TO BEAM BEARING. STRUCTURAL WOOD NOTES 65. ALL WOOD FRAMING ELEMENTS, INCLUDING BEAMS, PURLINS, COLUMNS AND DECKING TO BE STRUCTURAL GRADE: MINIMUM MODULUS OF ELASTICITY---------------- E = 1,500,000 PSI MINIMUM EXTREME FIBER BENDING -------------- Fb = 1,200 PSI MINIMUM COMPRESSION PARALLEL --------------- Fc = 1,000 PSI ROOF FRAMING NOTES 66. VERIFY ACTUAL WEIGHTS AND LOCATIONS OF ROOF SUPPORTED MECHANICAL AND REFRIGERATION EQUIPMENT WITH PLANS. REPORT DISCREPANCIES TO S.E.R.. 67. PROVIDE STEEL ANGLE FRAME AT ROOF DECK OPENINGS LARGER THAN 12" IN EITHER DIRECTION PER DETAIL THIS SHEET. 68. ELEVATIONS SHOWN THUS (+)22'-0" ARE REFERENCED FROM FINISHED FLOOR ELEVATION. 69. CONTRACTOR SHALL PROVIDE SHORING AND TEMPORARY SUPPORT AT NEW OPENINGS WHEN SETTING NEW LINTELS/BEAMS. 70. BRACE, WITHOUT OVERSTRESSING, STRUCTURAL ELEMENTS DURING CONSTRUCTION TO COMPLETE NEW SCOPE OF WORK. FLOOR NOTES 71. REPAIR EXISTING FLOOR SUCH THAT DEFECTS DO NOT TELEGRAPH THROUGH THE NEW FLOOR COVERING. USE ARMSTRONG, PORTLAND CEMENT BASED PATCHING MATERIAL (4000 PSI MINIMUM). USE THE ARMSTRONG PRODUCT APPROPRIATE FOR EACH APPLICATION SUCH AS, S-183 FAST SETTING CEMENT BASED UNDERLAYMENT; S-184 FAST SETTING CEMENT BASED PATCH AND SKIM COAT; OR S-194 PATCH, UNDERLAYMENT AND EMBOSSING LEVELER EITHER WITH OR WITHOUT S-195 UNDERLAYMENT ADDITIVE. CONSULT ARMSTRONG PRODUCT SUPPLIER FOR APPROPRIATE PRODUCTS AND ASSOCIATED APPLICATIONS. 72. FOR POLISHED CONCRETE FLOOR FINISH, FOLLOW POLISHING GUIDELINES BELOW: a. START PROCESS WITH 40 GRIT METAL BONDED DIAMOND PASS IN ORDER TO REMOVE EXISTING MASTICS AND ADHESIVES. THIS PROCESS SHOULD PRODUCE UNIFORM SCRATCH PATTERN RESULTING IN UNIFORM - CHALKING - OF CONCRETE SURFACE. b. REPAIR AND FILL SURFACE CRACKS AND HOLES AS NECESSARY USING MATERIALS DESIGNED FOR SHALLOW REPAIR. USE EPOXY MATERIALS AND BLEND AS BEST AS POSSIBLE TO SURROUNDING CONCRETE. REPAIRS WILL NOT BE PERFECT MATCH TO CONCRETE. GRIND REPAIRS FLUSH WITH SURROUNDING SURFACES. c. CONTINUE MECHANICAL GRINDING PROCESS USING 80 GRIT METAL BONDED DIAMOND PASS. d. FINISH MECHANICAL GRINDING PROCESS USING 150 GRIT METAL BONDED DIAMOND PASS. e. INSTALL PENETRATING DENSIFIER PER MANUFACTURER'S RECOMMENDATION. f. BEGIN POLISHING PROCESS WITH 100 GRIT RESIN BONDED DIAMOND PASS. PROVIDE MINIMUM 50% OVERLAP AND POLISH AT RATE FOR EVEN SCRATCH PATTERN FOR ALL PHASES. g. CONTINUE POLISHING PROCESS WITH 200 GRIT RESIN BONDED DIAMOND PASS. h. CONTINUE POLISHING PROCESS WITH 400 GRIT RESIN BONDED DIAMOND PASS. i. CONTINUE POLISHING PROCESS WITH 800 GRIT RESIN BONDED DIAMOND PASS. j. FINISH POLISHING PROCESS WITH 1500 GRIT RESIN BONDED DIAMOND PASS. k. APPLY PROTECTIVE SURFACE TREATMENT USING MICROFIBER APPLICATOR. l. HIGH SPEED BURNISH WITH 1500 GRIT DIAMOND IMPREGNATED BURNISHING PAD TO COMPLETE FLOOR FINISH m. POLISH FLOOR SURFACE FINISH EDGES NEAR STATIONARY OBJECTS, INCLUDING INTERIOR PARTITION WALLS. ALEXANDER CITY, AL NEW MASONRY LINTEL REINF w/(2)-#5 TOP AND BOTTOM, BEAR MINIMUM 8" ON EXISTING MASONRY EACH SIDE OF NEW OPENING PSF PSF PSF PSF PSF 08/23/10 (-)0'-8" DESIGN LOADS 3. TOTAL BASIC ROOF DESIGN LOAD -------------------------------------------------------------4. BASIC ROOF DESIGN DEAD LOAD - (UNIFORMLY DISTRIBUTED) ----------------------------5. BASIC ROOF DESIGN LIVE LOAD - (PLUS SNOW DRIFTING) ---------------------------------6. Pg -------------------------------------------------------------------------------------------------7. Pf --------------------------------------------------------------------------------------------------8. Ce -------------------------------------------------------------------------------------------------9. I ---------------------------------------------------------------------------------------------------10. Ct -------------------------------------------------------------------------------------------------11. BASIC WIND SPEED (3 SECOND GUST) --------------------------------------------------------12. WIND PRESSURE (MWFRS) ----------------------------------------------------------------------13. EXPOSURE FACTOR -----------------------------------------------------------------------------14. WIND IMPORTANCE FACTOR --------------------------------------------------------------------15. COMPONENTS AND CLADDING DESIGN WIND PRESSURE ------------------------------------16. NET UPLIFT ---------------------------------------------------------------------------------------17. SEISMIC USE GROUP ----------------------------------------------------------------------------18. SEISMIC DESIGN CATEGORY --------------------------------------------------------------------19. Ss -------------------------------------------------------------------------------------------------20. S1 -------------------------------------------------------------------------------------------------21. SITE CLASS ---------------------------------------------------------------------------------------- DATE: T/FND WALL 1612 MILLS SQUARE (+)0'-0" USE FOR NEW OPENING IN NEW MASONRY WALLS NOT TO EXCEED 5'-4" PRELIMINARY NOT FOR BID OR CONSTRUCTION 12" x 8" DEEP LINTEL BLOCK REINFORCE w/(2)-#5 BOTTOM CONTINUOUS L-1 tgp FIN FLR EL APPLICABLE CODES 1. INTERNATIONAL BUILDING CODE (IBC) 2006; ASCE 7-05; 2008 ACI FOR CONCRETE AND MASONRY; AISC 9TH EDITION FOR STEEL; STEEL JOIST INSTITUTE; STEEL DECK INSTITUTE. 2. STATE, COUNTY, CITY AND LOCAL CODES AS APPLICABLE FOR THIS CONSTRUCTION. CHECKED: EXISTING CONCRETE FLOOR SLAB TO REMAIN REMARKS DATE: REMOVE EXISTING MASONRY WALL AS REQUIRED FOR INSTALLATION OF NEW LINTEL SALVAGE AS REQUIRED FOR REUSE DETAIL DESCRIPTION DESCRIPTION: EXISTING EXTERIOR SIDEWALK TO REMAIN LINTEL NUMBER REV. NUMBER: GROUT SOLID AT DOOR HOUSING GENERAL NOTES LINTEL SCHEDULE CERTIFICATION: EXISTING WALL TO BE REMOVED FOR NEW DOOR SYSTEM FILL LEVEL w/ NEW 2500 psi CONCRETE mjw EXISTING MASONRY WALL TO REMAIN DRAWN: NOTE: SEE ARCHITECTURAL DRAWINGS FOR LOCATION STORE NUMBER PROJECT NUMBER 03510-01 SHEET TITLE STRUCTURAL NOTES AND DETAILS SHEET NUMBER S-1 BY: C "COMPANY NAME" 20XX ALL RIGHTS RESERVED DATE: DESCRIPTION: PRELIMINARY NOT FOR BID OR CONSTRUCTION REV. NUMBER: CERTIFICATION: G F E C D B A 174'-2" 20'-5" 30'-8" 20'-9" 15'-0" 30'-0" 12'-2" 30'-0" 30'-0" 1'-0" 12'-2" 149'-7" 14'-8" 134'-11" 6or7 S-1 16'-0" 33'-1" NEW STAIR, SEE 6 & 7/S-1, USE MOST COST EFFECTIVE DETAIL 6" NOTE: THE ASSUMPTION IS THAT THE PRIMARY ROOF FRAMING ELEMENTS ARE ON THE LETTERED GRIDS. IF ON NUMBERED GRIDS, RE-ORIENT CURBING AND DUNNAGE FRAMING AND DETAILS 90 DEGREES. DOES NOT AFFECT DOCK CANOPY FRAMING. 1 NEW RTU - 800# PROVIDE (2) WOOD CURBS x 15'-0" LONG SPANNING MNIMUM (3) EXISTING BAR JOISTS - REINF BAR JOISTS PER DETAIL 2/S-1 NEW L-2 LINTEL 3 STORE NUMBER 25'-10" 20'-0" ALEXANDER CITY, AL 58'-11" NEW L-2 LINTEL NEW RTU - 1600# PROVIDE (2) WOOD CURBS x 20'-0" LONG SPANNING MNIMUM (4) EXISTING BAR JOISTS - REINF BAR JOISTS PER DETAIL 2/S-1 08/23/10 1612 MILLS SQUARE NOTE: FIRST OPTION FOR CONDENSER LOCATION IS ON GRADE NEW RTU - 800# PROVIDE (2) WOOD CURBS x 15'-0" LONG SPANNING MNIMUM (3) EXISTING BAR JOISTS - REINF BAR JOISTS PER DETAIL 2/S-1 DATE: 90'-1" PROVIDE (1)W8x15 PER ONE PAIR OF CONDENSER LEGS AS REQUIRED TO EXTEND ACROSS EXISTING SUPPORT FRAMING. 43'-0" EXISTING DUNNAGE VERIFY SIZE AND LOCATION NEW RTU - 1600# PROVIDE (2) WOOD CURBS x 20'-0" LONG SPANNING MNIMUM (4) EXISTING BAR JOISTS - REINF BAR JOISTS PER DETAIL 2/S-1 PRIMARY FRAMING DIRECTION NOTE: PROVIDE HANDRAIL AT ROOF EDGE AT CONDENSER LOCATIONS, IF CONDENSER IS LESS THAN 10' FROM ROOF EDGE PRIMARY FRAMING DIRECTION PLACE NEW CONDENSER UNIT 3000# - 4500# ON EXISTING DUNNAGE PRIMARY FRAMING DIRECTION 84'-8" NEW L-3 LINTEL DRAWN: CONDENSER LOCATION SHOULD BE FIELD VERIFIED tgp 2 CHECKED: NEW L-2 LINTEL mjw NEW 4'-0"x 4'-0" POURED CONCRETE PAD ON EXISTING CONCRETE SLAB (VERIFY DEPTH REQUIRED) 31'-8" 21'-3" NEW L-2 LINTEL PROJECT NUMBER 03510-01 1'-0" SHEET TITLE 1'-0" 4 REAR NORTH RIGHT 14'-1" FRONT 20'-1" 8" 11'-1" 3'-11" 1'-0" 137'-5" 1'-0" SHEET NUMBER 1'-0" 189'-3" LEFT 1 STRUCTURAL PLAN STRUCTURAL PLAN SCALE: 1/8" = 1'-0" S-2 G F E C D B A 4. CONTRACTOR SHALL FIELD VERIFY BUILDING & SITE SEWER DEPTHS PRIOR TO STARTING WORK. NOTIFY ARCHITECT/ENGINEER IF DEPTHS ARE INADEQUATE. 5. VERIFY ROUGH-IN INFORMATION FOR EQUIPMENT & CASES WITH EQUIPMENT SUPPLIER. 6. VERIFY EXACT LOCATIONS OF ROOF & FLOOR OPENINGS FOR DRAINS & VENTS. 7. COORDINATE PIPING WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS. 8. COORDINATE ALL WASTE PIPING TO AVOID REFRIGERATION TRENCHING. REFER TO REFRIGERATION PLAN FOR PIT LOCATIONS. 9. VERIFY FOOTING LOCATIONS, SIZES, & DEPTHS PRIOR TO WASTE PIPE INSTALLATION. WHERE FOOTINGS ARE ENCOUNTERED, OFFSET DRAIN & DRAIN PIPING TO AVOID FOOTING. 10. VERIFY FLOOR DRAIN LOCATIONS FOR REFRIGERATED CASES AND TRADE EQUIPMENT WITH PROJECT MANAGER AFTER REFRIGERATION CONTRACT IS AWARDED. 11. INSTALL VENTS THROUGH ROOF A MINIMUM OF 10'-0" FROM PARAPET WALLS & FRESH AIR INTAKES ON HVAC-UNITS. VENTS THRU ROOF SHALL BE 3" MINIMUM IN FREEZING CLIMATES, OR AS NOTED ON PLAN. 12. ROUTE VENT AND OTHER SERVICE PIPING ABOVE THE CEILING UNLESS NOTED OTHERWISE. ROUTE PIPING IN EXPOSED AREAS UP AS HIGH AS POSSIBLE. 13. ROUTE SOIL, WASTE & DRAIN PIPING BELOW THE FLOOR, UNLESS NOTED OTHERWISE. 14. SILICONE SEAL ALL PLUMBING FIXTURES TO WALL. 15. UNDERGROUND PIPING SHALL BE 3" MINIMUM. 16. PROVIDE FINAL CONNECTIONS TO NEW PLUMBING FIXTURES. VERIFY CONNECTIONS. 17. PROVIDE FINAL CONNECTIONS FOR CONDENSATE DRAIN LINES FROM PROCESS EQUIPMENT, CASES, & COOLERS TO FLOOR DRAINS. 18. SANITARY SEWER PIPING SHOWN IS BASED ON 1/8" PER FOOT PIPE SLOPE FOR ALL PIPING 3" AND LARGER. FIELD VERIFY BUILDING SEWER LOCATION AND INVERT ELEVATIONS. 19. VERIFY AND CAP-OFF UNUSED CONDENSATE DRAINS AT COMPLETION OF THE WORK. 20. INSTALL STAINLESS STEEL PREP SINKS, COUNTER SINKS, HAND SINKS & ASSOCIATED FIXTURES, UNLESS NOTED OTHERWISE. 21. LOCATE FLOOR DRAINS UNDER REFRIGERATED CASES NOT LESS THAN 30", MEASURED SIDE TO SIDE, FROM THE CENTERLINE OF THAT CASE. 22. CONDENSATE PIPING SHALL SLOPE AT 1/8" PER FOOT MINIMUM. 23. PROVIDE CLEANOUTS AS SHOWN ON THE DRAWINGS AND AS REQUIRED BY THE CODE. ACCESSIBILITY TO CLEANOUTS SHALL BE MAINTAINED. ADJUST CLEANOUT COVER FLUSH WITH FINISHED FLOOR. 24. PROVIDE ACCESS DOORS TO ALL INACCESSIBLE CLEANOUTS. 25. ALL SANITARY WASTE & VENT PIPING SHALL BE NO-HUB CAST IRON WITH STAINLESS STEEL CLAMPING BANDS OR SCHEDULE 40 PVC DRAIN, WASTE, & VENT WITH SOLVENT WELD SOCKET FITTINGS. SUPPORT ALL PIPING IN ACCORDANCE WITH TABLE 308.5, 2009 INTERNATIONAL PLUMBING CODE. 26. ALL HUB DRAIN ASSEMBLIES SHALL EXTEND ABOVE FINISHED FLOOR AS SHOWN ON DETAIL 1/P4. 27. ALL HUB DRAIN ASSEMBLIES SHALL BE PROVIDED BY PLUMBING CONTRACTOR. 28. DRAIN LINE FROM CASE TO HUB SHALL BE INSULATED W/ 3/8" ARMAFLEX INSULATION UNDER ALL PRODUCE CASES. EXPOSED PIPING IN PUBLIC SPACES SHALL BE 1/2" FIBERGLASS WITH WHITE ALL SERVICE JACKET. 29. ALL SANITARY TEES SHALL BE COMBINATION TEES. 30. PLUMBING CONTRACTOR SHALL TAKE ALL PRECAUTIONS TO ENSURE POSITIVE DRAINAGE IN ALL PREP AREAS, RESTROOMS & COOLERS. 31. PROVIDE 1" MINIMUM, OR AS REQUIRED BY LOCAL CODE AIR GAP BETWEEN CASE DRAINS & HUB DRAINS. VIDEO SCOPE ALL SANITARY LINES TO INSPECT CONDITION OF PIPING AND TO LOCATE AND REMOVE ALL BLOCKAGES 32. C "COMPANY NAME" 20XX ALL RIGHTS RESERVED (-) INDICATES INVERT FROM FINISHED FLOOR LINE. PRELIMINARY NOT FOR BID OR CONSTRUCTION 3. DATE: FLOOR ELEVATION SHALL BE CONSIDERED AS 0'-0". ELEVATIONS SHOWN SHALL BE BASED ON THIS REFERENCE. DESCRIPTION: 2. REV. NUMBER: GENERAL NOTES ARE APPLICABLE TO ALL PLUMBING WORKING DRAWINGS. REFER TO SHEET P-3 PLUMBING SCHEDULES AND P-4 PLUMBING DETAILS FOR ADDITIONAL INFORMATION. CERTIFICATION: 1. BY: GENERAL NOTES KEYED NOTES 15 4" 1 HS-1, MEAT PREP HAND SINK W/ 1-1/2" WASTE & VENT CONNECTIONS. SINK PROVIDED BY PLUMBING CONTRACTOR. SPLASH GUARD ON RIGHT SIDE OF SINK. 2 2" VENT UP WITH CO-2 CLEAN 0UT AT BASE OF RISER, OFFSET OVER TO NEAREST VENT THRU ROOF. 3 2" VENT UP, OFFSET OVER TO NEAREST VENT THRU ROOF. 4 2" VENT UP TO 3" VENT THRU ROOF, EXCEPT AS NOTED ON PLAN. 5 DROP 1" CONDENSATE DRAIN LINE DOWN ON WALL SURFACE. TERMINATE PIPE AT FLOOR SINK. MAINTAIN 2" MINIMUM AIR GAP BETWEEN END OF CONDENSATE PIPE AND TOP OF FLOOR SINK. 6 CS-1, 3-COMP. PRODUCE SINK W/ 2" WASTE & VENT CONNECTIONS. PROVIDE IN-DIRECT WASTE CONNECTION TO FS-1, FLOOR SINK. SEE DETAIL 2/P-4. SINK PROVIDED BY PLUMBING CONTRACTOR. 7 CS-2, 3-COMP. MEAT SINK W/ 2" WASTE & VENT CONNECTIONS. PROVIDE IN-DIRECT WASTE CONNECTION TO FS-1, FLOOR SINK. SEE DETAIL 2/P-4. SINK PROVIDED BY PLUMBING CONTRACTOR. 8 GT-1, GREASE INTERCEPTOR. MOUNT BELOW FLOOR. SEE DETAIL 3/P-4. 9 REFRIGERATION PIT FORMED BY GENERAL CONTRACTOR. 10 PLUMBING CONTRACTOR TO PROVIDE (1) 3" SCHEDULE 40 PVC PIPE & (1) 8" SCHEDULE 40 PVC PIPES FOR USE BY THE REFRIGERATION & ELECTRICAL CONTRACTORS FOR REFRIGERATION PIPING & ELECTRICAL WIRING. COORDINATE EXACT REQUIREMENTS WITH REFRIGERATION CONTRACTOR PRIOR TO STARTING CONSTRUCTION. CONCRETE DEMOLITION, REFRIGERATION PIT FORMATION & CONCRETE REPAIR BY GENERAL CONTRACTOR. 11 REFRIGERATION CASE CONDENSATE DRAIN LINE. FIELD VERIFY LOCATION OF REFRIGERATED CASE WITH PROJECT MANAGER & REFRIGERATION CONTRACTOR PRIOR TO INSTALLATION. SEE DETAIL 9/P-4. 12 TIE DRAIN FROM THIS CASE INTO HUB DRAIN OF A SIMILAR ADJACENT CASE ABOVE SLAB. 13 FREEZER COIL WITH CONDENSATE DRAIN LINE. FREEZER COIL BY REFRIGERATION CONTRACTOR. SEE DETAIL 7/P-4. 14 COOLER COIL WITH CONDENSATE DRAIN LINE. COOLER COIL BY REFRIGERATION CONTRACTOR. SEE DETAIL 8/P-4. 15 EXISTING 4" SANITARY WASTE FROM ADJACENT TENANT SPACE. FIELD VERIFY EXACT ROUTING AND INVERT ELEVATION. 16 COORDINATE WITH GENERAL CONTRACTOR THE LOCATIONS OF FLOOR SLOPE T0 RECESSED FLOOR DRAIN . 17 MS-1, MOP SINK WITH 3" FD-2 FLOOR DRAIN, 3" WASTE AND 2" VENT CONNECTIONS. FLOOR-SET MOP SINK FLOOR DRAIN FURNISHED BY PLUMBING CONTRACTOR. MOP RACK FOR HANGING MOPS TO BE PROVIDED AS ACCESSORY WITH MOP SINK. 18 NEW GAS-FIRED WATER HEATER MOUNTED ON TOP OF MEAT COOLER COMPLETE WITH 3/4" RIGID COPPER DRAIN LINE FROM T & P SAFETY VALVE DOWN TO FLOOR DRAIN. TERMINATE DRAIN LINE A MINIMUM OF 1" ABOVE TOP OF FLOOR DRAIN. 19 1-1/2" VENT UP WITH CLEAN OUT CO-2 AT BASE OF RISER. OFFSET OVER TO NEAREST VTR. 20 EWCH-1, ADA-COMPLIANT WATER COOLER WITH 1-1/2" WASTE AND 1-1/2" VENT CONNECTIONS. FIXTURE FURNISHED BY PLUMBING CONTRACTOR. 21 (-15") INITIAL INVERT ELEVATION FROM TOP OF FINISH FLOOR ASSUMING AN EXISTING 4" CONCRETE SLAB THICKNESS. 2 11 12 12 12 CWV CWV 4" CO-1 5 4 CO-1 CO-1 CO(E) 4 21 8 CO-1 FREEZER 110 2" 100 9 10 MEAT PREP 4 CO-1 PRODUCE COOLER SAN(E) 113 108 10 1-1/2" SALES AREA 9 COND 9 HD-1 SAN(E) COND VESTIBULE 2" HD-1 19 14 13 CWV 11 V 4" SAN 4" 3" 11 11 101 CWV HD-1 CO(E) V HD-1 4" 1-1/2" CWV CO(E) V 4 CO-1 20 3" 31 4"FS-1 4 V 30 4" 4" 2" FD(E) 12 SAN(E) WOMEN 115 CO(E) 31 29 FD(E) 29 CO(E) 4" CO(E) 2 17 28 V 12 DAIRY COOLER 22 29 3" 102 114 28 31 MEN SAN(E) 24 31 3 SAFE 4"FD-2 -(1/2") COND 2 16 11 107 12 HD-1 12 11 3" (TYP.) STORE NUMBER 103 27 HD-1 CO-1 2 3" SAN(E) CWV(E) CWV(E) 14 11 12 12 12 11 HD-1 12 ALL PLUMBING IN RESTROOMS BY LANDLORD FURNISHED IN "AS IS" CONDITION. PLUMBING CONTRACTOR TO MAKE REVISIONS TO FIXTURES AS NOTED. 23 4" SANITARY SEWER PIPE BUILDING CLEAN OUT. VERIFY INVERT ELEVATION. 24 HS-2, PRODUCE PREP HAND SINK W/ 1-1/2" WASTE & VENT CONNECTIONS. SINK PROVIDED BY PLUMBING CONTRACTOR. SPLASH GUARD ON LEFT SIDE OF SINK. 25 NOT USED. HD-1 11 26 NOT USED. 27 3/4" CONDENSATE DRAIN LINE FROM SPLIT SYSTEM INDOOR MODULE TO HUB DRAIN. 28 DEMO EXISTING WATER CLOSET. PERMANENTLY CAP OFF WASTE & VENT PIPING AT MAINS. 29 EXISTING WATER CLOSET. CLEAN FIXTURE FOR NEW SAVE-A-LOT TENANT. 4" BREAK ROOM 104 4 3"VTR (E) 30 DEMO EXISTING URINAL. PERMANENTLY CAP OFF WASTE & VENT PIPING AT MAINS. 31 EXISTING LAVATORY. CLEAN FIXTURE FOR NEW SAVE-A-LOT TENANT. RIGHT CO(E) NORTH REAR FRONT 23 DRAIN, WASTE & VENT PLAN 03510-01 DRAIN, WASTE & VENT PLAN SHEET NUMBER P-1 LEFT 1 PROJECT NUMBER SHEET TITLE CWV(E) CO(E) HD-1 22 OFFICE 2" 4" 22 29 3"VTR (E) 11 HD-1 4" V HD-1 V 6 08/23/10 2 HD-1 4"FD-2 -(1/2") 14 18 11 SCALE: 1/8" = 1'-0" ALEXANDER CITY, AL GW 117 4"FD-2 -(1/2") 16 16 4" CWV COND BACK ROOM 'B' GW 1"(TYP.) COND 4" DATE: HD-1 1612 MILLS SQUARE 12 14 RJK 4" CHECKED: 4"FS-1 RNC 7 1 109 14 HD-1 CWV MEAT COOLER CO (TYP.) 1 11 3" (TYP.) DRAWN: SAN(E) HD-1 V SAN(E) 15 FIELD VERIFY ALL CONDITIONS PRIOR TO STARTING WORK. 4 VERIFY ROUGH-IN INFORMATION FOR EQUIPMENT AND CASES WITH EQUIPMENT SUPPLIER. 5. FLOOR ELEVATION SHALL BE CONSIDERED AS 0'-0". ELEVATIONS SHOWN SHALL BE BASED ON THIS REFERENCE. 6. ROUTE WATER AND OTHER SERVICE PIPING ABOVE THE CEILING UNLESS NOTED OTHERWISE. ROUTE PIPING IN EXPOSED AREAS UP AS HIGH AS POSSIBLE. 7. AVOID ALL REFRIGERATION TUNNELS UNLESS NOTED OTHERWISE. 8. ALL SUPPLY WATER PIPING TO BE: -TYPE L COPPER OR CPVC -INSULATED WITH 1/2" JACKETED FIBERGLASS OR 3/8" ARMAFLEX -SUSPENDED FROM TOP CHORD OF BAR JOISTS -SUPPORTED IN ACCORDANCE WITH TABLE 308.5, 2009 INTERNATIONAL PIPING CODE -PIPING EXPOSED TO PUBLIC VIEW SHALL BE WHITE 9. PROVIDE FINAL CONNECTIONS TO PLUMBING FIXTURES. 10. PROVIDE COLD WATER SUPPLY WITH SHUT-OFF VALVE & BACKFLOW PREVENTER TO FRESH PRODUCE CASE FOR CONNECTION TO PRODUCE MISTING SYSTEM PROVIDED & INSTALLED BY REFRIGERATION CONTRACTOR. 11. PROVIDE WATER FILTER ON WATER CONNECTION TO PRODUCE MISTING SYSTEM. 12. PROVIDE SHUT-OFF VALVES ON HOT & COLD WATER SUPPLY BRANCHES TO PREP AREAS & RESTROOMS. 13. INSTALL STAINLESS STEEL PREP SINKS, COUNTER SINKS, HAND SINKS & ASSOCIATED FAUCETS & PLUMBING ACCESSORIES, UNLESS NOTED OTHERWISE. 14. PROVIDE CHECK VALVES ON HOT & COLD WATER SUPPLY LINES TO EACH PRE-RINSE FAUCET FOR SERVICE SINKS. 15. PROVIDE WATER HAMMER ARRESTORS ON HOT & COLD WATER SUPPLY BRANCH RUNS TO HOSE & SPRAY FAUCETS & FLUSH VALVES. 16. SILICONE SEAL FIXTURES TO WALL. 17. REMOVE & DISPOSE OF ABANDONED PIPING & RUNOUTS AND CAP AT MAINS IN EXISTING BUILDINGS. PROVIDE 3" MINIMUM LENGTH DIRT LEGS ON ALL GAS PIPING CONNECTIONS TO EQUIPMENT. CERTIFICATION: 18. C "COMPANY NAME" 20XX ALL RIGHTS RESERVED 3 PRELIMINARY NOT FOR BID OR CONSTRUCTION COORDINATE PIPING WITH ALL OTHER TRADES PRIOR TO INSTALLATION TO AVOID CONFLICTS. DATE: 2. DESCRIPTION: IT IS THE RESPONSIBILITY OF THE PLUMBING CONTRACTOR TO COMPLY WITH STATE & LOCAL PLUMBING CODES, AND VERIFY THE ACCEPTABILITY OF SINKS, DRAINS & RELATED ITEMS. REQUIREMENT ITEMS INCLUDE, BUT ARE NOT LIMITED TO GREASE INTERCEPTORS, BACKFLOW PREVENTERS & SINKS. REV. NUMBER: 1. BY: GENERAL NOTES G F E C D B A 19 4 H-1, HOSE BIBB W/ 1/2" HOT & COLD WATER CONNECTIONS. MOUNT BELOW SINK DRAINBOARD @ 2'-0" A.F.F. SEE DETAIL 5/P-4. 5 H-2, HOSE BIBB W/ 3/4" COLD WATER CONNECTION @ 3'-0" A.F.F. MOUNT SHUT-OFF VALVE AT TOP OF CASE OUT OF PUBLIC VIEW. 6 1" HOT & COLD WATER LINE THRU WALL DOWN TO BELOW SINKS & ROUTED EXPOSED ON WALL TO SERVE SINKS & HOSE BIBB. 7 MS-1, MOP SINK. MOP SINK AND ACCESSORIES FURNISHED BY PLUMBING CONTRACTOR. 8 GHW-1, GAS-FIRED WATER HEATER W/ 1-1/4" WATER CONNECTIONS, 1/2" NATURAL GAS CONNECTION, AND SEALED COMBUSTION AIR INTAKE AND POWERED EXHAUST VENT SYSTEM . MOUNT WATER HEATER ON MEAT COOLER. SEE DETAIL 6/P-4 FOR PIPING AND 10/P-4 FOR VENTING. 120 MBH GAS CONSUMPTION RATE. 9 EXISTING 1-1/2" CW SUPPLY FROM MEZZANINE (FIELD VERIFY EXACT ROUTING BACK TO METER). 10 EWCH-1, ADA-COMPLIANT ELECTRIC WATER COOLER WITH 1/2" CW CONNECTION. FIXTURE FURNISHED BY PLUMBING CONTRACTOR. 11 EXISTING OVERHEAD WATER SUPPLY TO FRONT OF STORE. 12 NOT USED. 13 WATER METER FURNISHED AND INSTALLED BY CITY. VERIFY INSTALLATION LOCATION WITH CITY WATER METER DEPARTMENT AND SAVE-A-LOT PROJECT MANAGER. 2" BUILDING DOMESTIC WATER SUPPLY ENTERS BUILDING WEST OF MEZZANINE IN ADJACENT TENANT SPACE. SUB-METERING OF ADJACENT TENANT SPACE BY SAVE-A-LOT MAY BE REQUIRED. VERIFY EXACT METERING ARRANGEMENT. SEE DETAIL 11/P-4 FOR PIPING ARRANGEMENT TO SAVE-A-LOT TENANT SPACE. SEE DETAIL 12/P-4 FOR TYPICAL DOMESTIC WATER SERVICE PIPING. 14 GAS DOWN TO EXISTING METER. REPLACEMENT GAS METER FURNISHED AND SET BY GAS COMPANY AS NEEDED TO SUPPLY 670 CFH NATURAL GAS AT 2 PSIG SYSTEM PRESSURE. 15 ASTM A53/A53M SCHEDULE 40, TYPE E OR S, GRADE B, BLACK STEEL 2 PSIG NATURAL GAS PIPING TO AC UNITS AND WATER HEATER (240 FEET OF TOTAL DEVELOPED LENGTH @ 10 PERCENT PRESSURE LOSS). FIELD-VERIFY EXACT LOCATION OF CONNECTION TO EXISTING GAS METER & GAS DELIVERY SUPPLY PRESSURE. PROVIDE GAS PIPING SUPPORT ON ROOF WITH MIRO MODEL 1.5 PIPE SUPPORT SPACED PER MANUFACTURER'S RECOMMENDATIONS. PLUMBING CONTRACTOR TO VERIFY THAT INSTALLATION WILL DELIVER ADEQUATE TO GAS PRESSURE REQUIRED BY GAS-FIRED EQUIPMENT AT POINT OF CONNECTION. LANDLORD TO PROVIDE A SEPARATELY METERED GAS CONNECTION FOR TENANT SPACE OCCUPIED BY SAVE-A-LOT STORE. PLUMBING CONTRACTOR TO COORDINATE GAS REQUIREMENTS WITH LANDLORD & GAS COMPANY. 114 16 AC-1, ROOF TOP UNIT WITH 3/4" GAS CONNECTION. 200 MBH. 21 17 AC-2, ROOF TOP UNIT WITH 3/4" GAS CONNECTION. 150 MBH. 18 AC-3, ROOF TOP UNIT WITH 1/2" GAS CONNECTION. 120 MBH. 19 AC-4, ROOF TOP UNIT WITH 1/2" GAS CONNECTION. 80 MBH. 20 NOT USED. 21 DEMO EXISTING WATER CLOSET. PERMANENTLY CAP OFF WATER SUPPLY PIPING IN WALL. 22 EXISTING WATER CLOSET. CLEAN FIXTURE FOR NEW SAVE-A-LOT TENANT. 23 DEMO EXISTING URINAL. PERMANENTLY CAP OFF WATER SUPPLY PIPING IN WALL.. 24 EXISTING LAVATORY. CLEAN FIXTURE FOR NEW SAVE-A-LOT TENANT 25 REFRIGERATION CONTRACTOR SHALL INSTALL OWNER SUPPLIED MISTING SYSTEM. 26 GAS COCK AND POUNDS-TO-INCHES NATURAL GAS PRESSURE REGULATOR BY PLUMBING CONTRACTOR. SEE DETAIL 12/P-4. G 12 (E) CONC FREEZER SLAB @ -4" BELOW F.F.E. 4 1" 3 3/4" MEAT COOLER 109 1" 2 8 MEAT PREP G VESTIBULE 100 16 108 26 26 BACK ROOM 'B' 117 SALES AREA G 110 G FREEZER (E) CONC COOLER SLAB @ F.F.E. 101 PRODUCE COOLER 1" 113 G G 11 9 G 13 1/2" 26 4 15 2 14 G 6 23 10 17 24 1-1/4" 26 18 SAFE 102 MEN 1 3 STORE NUMBER WOMEN 115 24 DAIRY COOLER 107 OFFICE 103 PROJECT NUMBER 22 22 21 SHEET TITLE BREAK ROOM 104 7 22 4 NORTH RIGHT REAR FRONT DRAIN, WASTE & VENT PLAN ABOVE GROUND PIPING PLAN SHEET NUMBER P-2 LEFT 1 03510-01 SCALE: 1/8" = 1'-0" ALEXANDER CITY, AL CS-2, 3-COMP. MEAT SINK W/ 1/2" HOT & COLD WATER CONNECTIONS TO EACH FAUCET. SEE DETAIL 5/P-4. SINK FURNISHED BY PLUMBING CONTRACTOR. 6 1 08/23/10 3 (N) CONC STOOP DATE: CS-1, 3-COMP. PRODUCE SINK W/ 1/2" HOT & COLD WATER CONNECTIONS TO FAUCET. SEE DETAIL 5/P-4. SINK FURNISHED BY PLUMBING CONTRACTOR. 5 1612 MILLS SQUARE 2 1 25 RJK HS-1, HAND SINK W/ 1/2" HOT & COLD WATER CONNECTIONS. PROVIDE W/ MV-1, MIXING VALVE. SEE DETAIL 4/P-4. SINK FURNISHED BY PLUMBING CONTRACTOR. CHECKED: 1 RNC KEYED NOTES 26 DRAWN: (E) CONC FREEZER SLAB @ -4" BELOW F.F.E. STORE NUMBER PROJECT NUMBER 03510-01 SHEET TITLE PLUMBING SCHEDULES SHEET NUMBER P-3 ALEXANDER CITY, AL 1612 MILLS SQUARE DATE: CHECKED: DRAWN: 08/23/10 RJK RNC CERTIFICATION: PRELIMINARY NOT FOR BID OR CONSTRUCTION DESCRIPTION: DATE: C "COMPANY NAME" 20XX ALL RIGHTS RESERVED REV. NUMBER: BY: H 45 ITC P TEE UP UNION -TYPICAL FLOOR SINK BACKFLOW PREVENTER 1 1/2" MAX. TOP OF COUPLING TO BE 1/2" ABOVE FINISHED FLOOR INSULATE @ ALL ELECTRIC HEAT TAPED PIPES SHUT OFF VALVE FLOOR SINK (RECESSED) CHECK VALVE HD-1; SUPPLEMENTARY STRAINER FOAM SEAL ALL PIPE PENETRATION VENT WALL HYDRANT PROVIDE 3"x 4" CAST IRON OR PVC COUPLING ON TOP OF PIPE. 4" UNION EXIST'G FLOOR SINK VENT (EXISTING) LEVER HANDLE GAS COCK VENT THRU ROOF GAS PRESSURE REGULATOR VENT THRU ROOF (EXISTING) M CLEANOUT 7 FREEZER EVAP. DRAIN PIPING SCALE: NONE 1 HUB DRAIN (HD-1) SCALE: NONE TEE CLEANOUT (EXISTING) CAPPED LINE TRENCH DRAIN 4" CLEANOUT 4" EVAPORATOR INSULATED COOLER PANEL WALLS & CEILING EVAPORATOR 2" VENT UP TO V.T.R. (VENT THRU ROOF) EXIST'G TRENCH DRAIN 3 COMPARTMENT SINK (N.I.C.) TRENCH DRAIN (RECESSED) ELBOW RELIEF VALVE ANGLE VALVE TIGHT TO TAIL PIECE 1/8" PER FT. V PITCH AIR GAP PER CODE UNION ROOF DRAIN (EXISTING) CLEANOUT -TYPICAL 2" (TYPICAL) UNION -TYPICAL CLEANOUT (TYPICAL) TRAP PRIMER ROOF DRAIN LEADER FS-1, FLOOR SINK ROOF DRAIN LEADER (EXISTING) FLOOR LINE NOTE: NOT ALL OF THE ABOVE SYMBOLS APPEAR ON THE PLANS COPPER PIPE SUPPORTS & BRACKETS -36" TO 48" O.C. MAX. 4" 4" WASTE TO SEWER LINE FOR PRODUCE SINK. 4" WASTE TO GREASE TRAP FOR MEAT SINK. NOTE: UNIONS MUST BE LOCATED OUTSIDE OF PAN AREA TO FACILITATE CLEAING COOLER EVAP. DRAIN PIPING SCALE: NONE WATER HAMMER ARRESTER 2 3 COMP. SINK DWV PIPING SCALE: NONE 2" VENT UP IN WALL VENT TEE CONECTION ABBREVIATION DESCRIPTION DOMESTIC COLD WATER AFF ABOVE FINISHED FLOOR HW DOMESTIC HOT WATER CO CLEANOUT HWR DOMESTIC HOT WATER RECIRC. CWV COMBINED WASTE AND VENT FILTERED WATER GW GREASE WASTE GALLONS PER MINUTE SAN SANITARY SEWER GAS PIPING RW STORM PIPING CFH CUBIC FEET OF GAS PER HOUR RDL ROOF DRAIN LEADER PRV PRESS. RELIEF VALVE VTR VENT THROUGH ROOF RD ROOF DRAIN F G RUNNING TRAP DESCRIPTION CONNECT TO EXISTING CW GPM PVC CASE DRAIN REFRIGERATED CASE -NIC ABBREVIATION BALL VALVE V CERTIFICATION: HUB DRAIN -SEE 1/P-4.1 8 ROOF DRAIN COOLER 1" MAX. DE G VENT CLEANOUT FLOOR LINE GREASE TRAP HUB DRAIN -SEE 1/P-4 FLOOR LINE SANITARY WASTE-ABOVE GRADE 4" I.W. MAIN EXIST'G SANITARY WASTE-ABOVE GRADE CLEAN-OUT SANITARY WASTE-BELOW GRADE SEE SINK DETAIL 2 FOR CONTINUATION 4" EXIST'G SANITARY WASTE-BELOW GRADE TRAP TO BUILDING MAIN VERIFY EXTENSION SIZE WITH INVERT 9 TYPICAL CASE DRAIN SCALE: NONE 3 COMBINED WASTE & VENT-BELOW GRADE RECESSED INTERIOR GREASE TRAP EXIST'G COMBINED WASTE & VENT-BELOW GRADE GREASE WASTE PIPING-BELOW GRADE MINIMUM OF 48" SEPARATION BETWEEN EXHAUST AND INTAKE TERMINALS STORM DRAIN PIPING EXIST'G STORM DRAIN PIPING PIPING EXPOSED BELOW SINK. PIPING IN WALL. STORM DRAIN PIPING-BELOW GRADE MV-1: MIXING VALVE MOUNTED BELOW SINK. EXHAUST TERMINAL PLUMBING ROOF BOOT OR EQUIVALENT FLASHING ROOF HAND SINK OR LAV 120 DEG. F. EXIST'G STORM DRAIN PIPING-BELOW GRADE FLOOR. SANITARY VENT NOTE: LOCATE MIXING VALVE PER PLANS. TEMPERATURE OF HOT WATER AT FAUCET SHALL NOT EXCEED 120 DEG. F. 3" PVC PIPE (TYPICAL) * SEALED COMBUSTION GAS WATER HEATER DRAINLINES -CASES,COOLERS & FREEZERS COND DIRECTION OF FLOW RJK INTAKE CHECKED: * INSTALL PER MANUFACTURER'S INSTRUCTIONS; VENT THROUGH EITHER ROOF OR WALL; USE MANUFACTURER PROVIDED VENT TERMINALS RNC EXIST'G SANITARY VENT 08/23/10 12" ABOVE AVERAGE SNOWFALL; MAXIMUM OF 24" ABOVE ROOF EXIST'G GREASE WASTE PIPING-BELOW GRADE DATE: INTAKE TERMINAL 40 DEG. F. 140 DEG. F. 3" PVC COUPLING (TYPICAL) 4 EXHAUST MV-1 MIXING VALVE SCALE: NONE FIRE PROTECTION PIPING-BELOW GRADE HOT & COLD WATER SUPPLY LINES DOWN -SEE PLAN FOR SIZE FLOOR FIRE PROTECTION PIPING EXISTING FIRE PROTECTION PIPING STOP / CHECK VALVE -MOUNT AT 7'-6" A.F.F. COLD WATER EXIST'G COLD WATER HOT & COLD WATER SUPPLY LINES 3 COMPARTMENT SINK (N.I.C.) 10 SCALE: NONE SEALED COMBUSTION VENTS H-1 HOSE BIBB -MOUNT AT 2'-0" A.F.F. EXPOSED PIPING UNDER SINK 2. STRAINER 3. 1-1/2" DOUBLE CHECK BACKFLOW PREVENTER EXPOSED SHUT-OFF VALVE (TYPICAL) ELBOW WATER SUPPLY LINES OUT FROM COOLER WALL BELOW SINK (TYPICAL) REVERSE OSMOSIS WATER RO FLOOR LINE HOT WATER EXIST'G HOT WATER 4. 1-1/2" DOMESTIC WATER METER 5 EXISTING DOMESTIC WATER SERVICE TO ADJACENT TENANT 1-1/2" TO FIXTURES (CONNECT TO EXISTING) LONG SWEEP ELBOW 1. EXIST'G COLD WATER-BELOW GRADE COLD WATER-UNTREATED HARD EXPOSED CHECK VALVES 1. 1-1/2" GATE VALVE COLD WATER-BELOW GRADE 3 COMP. SINK WTR. PIPING W/ HB 140 DEG.F. 4. 40 DEG.F. SCALE: NONE VACUUM RELIEF VALVE. (PROVIDE WHEN HEATER IS SUSPENDED ABOVE FIXTURES) HOT WATER-BELOW GRADE ALEXANDER CITY, AL PRE-RINSE FAUCET (N.I.C.) PROVIDE CHECK VALVES ON HOT & COLD WATER SUPPLY LINES TO FAUCET 1612 MILLS SQUARE SCALE: NONE 45 GAS PRESSURE REGULATOR TOE SPACE 12 PRELIMINARY NOT FOR BID OR CONSTRUCTION MECH. GAS SHUT-OFF VALVE REV. NUMBER: 3" CAST IRON OR 3" PVC PIPE W/ TRAP TO CONDENSATE SEWER SYSTEM DIRT LEG W/ MINIMUM 4" LONG NIPPLE AND CAP DRAWN: 2 P.S.I. BRANCH FROM MAIN FLOOR LINE 1" MIN. TRAP @ FREEZER HUB DRAIN -SEE 1/P-4.1 TEE DOWN FLOOR DRAIN (RECESSED) DESCRIPTION: 12" - 14" W.C. TO APPLIANCE ELBOW UP 1" AIR GAP 45 DE G TEST TEE W/ PLUG, SAME SIZE AS REGULATOR OUTLET. ELBOW DOWN FLOOR DRAIN/HUB DRAIN EXIST'G FLOOR DRAIN/HUB DRAIN CLEANOUT -TYPICAL FREEZER COPPER PIPE SUPPORTS & BRACKETS -36" TO 48" O.C. CONDENSATE LINES FROM REFRIGERATED CASES - NIC C "COMPANY NAME" 20XX ALL RIGHTS RESERVED D DATE: CLEANOUT GAS PRESSURE REGULATOR BALL VALVE (A.G.A. RATED) INSULATED FREEZER PANEL WALL & CEILING EVAPORATOR EG BY: TIGHT TO TAIL PIECE REGULATOR VENT PIPE W/ 90 DEGREE SCREENED VENT ELBOW TURNED DOWN. FOR REGULATORS INSTALLED INDOORS, EXTEND UP THROUGH ROOF. TERMINATE AT 30" ABOVE ROOF. EXIST'G HOT WATER-BELOW GRADE STORE NUMBER RECIRC. HOT WATER 1. 3. EXIST'G RECIRC. HOT WATER CHECK VALVE 2. 2" PROJECT NUMBER 03510-01 TEMP. OUTPUT THERMOMETER GATE VALVE (TYPICAL) DIELECTRIC UNION (TYP) EXPANSION TANK GAS PIPING ON ROOF SHEET TITLE EXIST'G GAS PIPING ON ROOF FLOW 125 POUND TEMPERATURE & PRESSURE RELIEF VALVE. (TYP.) ANCHOR TO FLOOR / WALL AS REQUIRED EXIST'G GAS PIPING BELOW ROOF FINISHED FLOOR PIPE SUPPORT - DO NOT BURN THROUGH WALL OF ELBOW WATER HEATER 2" DOMESTIC WATER SERVICE (EXISTING) NOTE: SCOPE OF WORK BY LANDLORD N.I.C. 11 DOMESTIC WATER SERVICE SCALE: NONE GAS PIPING BELOW ROOF DRAIN VALVE (TYPICAL) PROVIDE 2" DEEP WELDED DRIP PAN WITH 3/4" NIPPLE & DRAIN LINE UNDER SUSPENDED WATER HEATER RUN DRAIN LINES TO NEAREST FLOOR DRAIN OR AS INDICATED 6 WATER HEATER SCALE: NONE PLUMBING DETAILS GAS PIPING BELOW GRADE SHEET NUMBER P-4 E C D B A BY: F DESCRIPTION: 18 26 23 PRELIMINARY NOT FOR BID OR CONSTRUCTION REV. NUMBER: 22 29 C "COMPANY NAME" 20XX ALL RIGHTS RESERVED DATE: G 32/12 1 25 1 32/12 (E) BACK ROOM 'B' 117 10 EXISTING RTU SERVING TRAINING ROOM TO REMAIN TRAINING ROOM MEAT COOLER MEAT PREP 109 108 - 6 T H 2 5 17 VESTIBULE T 100 AC-1 CERTIFICATION: 4 33 14 22/12 (E) 1 18 32 SALES AREA PRODUCE COOLER FREEZER 110 101 4 113 10 5 ROOF HATCH (E) 10/10 (E) BACK ROOM 'A' 5 20/20 111 MEN PRODUCE PREP AREA 27 17 114 6 112 MEZZANINE 4 AC-3 AC-2 20 T H - T 1 1 20 6 102 7 27 T 13 24 21 18 9 WOMEN BACK ROOM 'B' 115 117 RECEIVING 31 3 SAFE 6 DAIRY COOLER 11 12 116 30 OFFICE 103 4 16 8 5 3 107 BREAK ROOM 19 104 20 4 LEFT 1 HVAC PLAN GENERAL NOTES KEYED NOTES KEYED NOTES 1 FIELD VERIFY EXACT LOCATION OF ALL EQUIPMENT WITH PROJECT ENGINEER/OWNER PRIOR TO INSTALLATION. INFORM PROJECT ENGINEER/OWNER OF ANY EQUIPMENT ITEMS THAT REQUIRE RELOCATION. SEE DETAILS 5/M-2 AND 6/M-2 FOR EQUIPMENT ROOF CURB ASSEMBLY AND HOLD DOWN BRACKETING DETAILS. 20 1. EXISTING WATER CLOSETS AND URINALS TO BE REMOVED SHOWN FOR REFERENCE ONLY. MINIMUM TOILET EXHAUST AIRFLOW RATES BASED ON FIXTURE COUNT. 2 NOT USED. 21 2. MECHANICAL CONTRACTOR SHALL COORDINATE HVAC WORK WITH OTHER TRADES FOR COMPLETION AND COORDINATION OF THE PROJECT. 3 SS-1, SPLIT SYSTEM A/C UNIT. MOUNT INDOOR UNIT ON WALL AT 3" BELOW FINISHED CEILING. EXTEND PIPING TO CONDENSING UNIT ON ROOF. MOUNT THERMOSTAT AT 4'-0" A.F.F. SEE SPLIT-SYSTEM PIPING DETAIL 3/M-2. EXISTING ELECTRIC LOW BOY WATER HEATER ON MEZZANINE (SHOWN FOR REFERENCE ONLY). WATER HEATER IS A 38-GALLON 3380 WATT DUAL ELEMENT 208 VOLT SINGLE PHASE UNIT (MODEL #E61-40L-045 DV) AND SERVES THE EXISTING TOILET LAVATORIES. 22 DEMO EXISTING SUPPLY AIR DUCT FROM 20 FEET UNDER MEZZANINE UP TO DUCT RISER THROUGH ROOF DECK. COVER DUCT OPENING AT RISER TEE WITH 1/4 " X 1/4"GALVANIZED STEEL MESH. 23 32/12 SUPPLY AND RETURN AIR RISERS UP TO ROOF TOP UNIT AC-4. FIELD VERIFY EXACT LOCATION FOR RISER LOCATION. 24 EXISTING SUPPLY AIR DUCT SERVING EXISTING TOILET ROOMS. DUCT AND SUPLY AIR REGISTERS ON TOILET ROOM WALLS TO REMAIN. REBALANCE REGISTERS TO 200 CFM EACH. 25 AC-4, MECHANICAL CONTRACTOR TO PROVIDE AND INSTALL ROOF TOP HVAC UNIT AND ROOF CURB ON MEZZANINE ROOF. FIELD VERIFY EXACT LOCATION TO PLACE UNIT. 26 32/12 SUPPLY AND RETURN AIR DUCT RISERS FROM AC-4 DOWN THROUGH MEZZANINE FLOOR. FIELD VERIFY EXACT LOCATION FOR ROOF AND FLOOR PENETRATIONS. COORDINATE PENETRATION REQUIREMENTS WITH OTHER TRADES. INSULATE DUCTWORK AS NOTED. 3. MECHANICAL CONTRACTOR SHALL COORDINATE ALL DUCT & DIFFUSER LOCATIONS WITH LIGHTING & SPRINKLER LAYOUTS. 4. MECHANICAL CONTRACTOR SHALL VERIFY THAT ALL EQUIPMENT SHOWN ON THESE DRAWINGS WILL NOT CONFLICT WITH ANY DRAINS, VENTS, MECHANICAL PIPING OR ELECTRICAL INSTALLATIONS. 4 COORDINATE INSTALLATION OF DIFFUSER WITH NEW LIGHTING AND CEILING GRID. 5 BALANCING DAMPER. SIZE TO BE SAME AS DUCTWORK NOTED ON PLAN. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF GRILLES & DIFFUSERS INSTALLED IN CEILINGS. 6 PROVIDE TEMPERATURE/HUMIDITY SENSORS MOUNTED AT 7'-0" A.F.F. SENSOR SHALL SEND A SIGNAL TO THE EMS SYSTEM WHICH SHALL CYCLE RTU TO MAINTAIN TEMPERATURE AND/OR HUMIDITY SET POINT. 7 GR-3, RETURN GRILLE, 48x24 NECK. CONNECT 18x18 RETURN DUCT FROM RTU OPENING TO RETURN GRILLE. 8 GR-1, RETURN / TRANSFER GRILL, 12"X8" NECK, 200 CFM, MOUNT GRILLES ON EACH SIDE OF WALL 3" BELOW SUSPENDED CEILING IN BREAKROOM. 9 GR-1, RETURN / TRANSFER GRILL, 12"X8" NECK, 50 CFM, MOUNT GRILLES ON EACH SIDE OF WALL 3" BELOW SUSPENDED CEILING IN OFFICE. 27 MECHANICAL CONTRACTOR TO DEMO EXISTING ABANDONED CULINARY HOODS AND DUCTWORK LOCATED NEAR FRONT OF STORE. FIELD VERIFY EXACT REQUIREMENTS FOR DEMOLITION. 10 EXISTING ROUND SUPPLY AIR DIFFUSER. REBALANCE TO 1000 CFM. 28 11 EF-1, ROOF-MOUNTED EXHAUST FAN COMPLETE WITH FACTORY-FABRICATED ROOF CURB FURNISHED & INSTALLED BY MECHANICAL CONTRACTOR. REUSE EXISTING ROOF-OPENING AND MODIFY TO SUIT NEW INSTALLATION. ADJUST FAN TO 450 CFM EXHAUST. SEE DETAIL 7/M-3. MECHANICAL CONTRACTOR TO REMOVE OR ABANDON IF FEASIBLE ALL EXISTING SUPPLY AND RETURN SYSTEM DUCTWORK STARTING AT CONNECTIONS TO EXISTING INTERIOR AIR HANDLING UNIT IN BACK ROOM AND CONCLUDING WITH THE LAST RUNS OF DUCTWORK OUT IN THE STORE SPACE. ABANDON AIR HANDLING UNIT IN PLACE. 5. 6. NOT ALL SYMBOLS LISTED ON M-2 ARE USED. 7. BRANCH DUCT SIZES NOT SHOWN ARE SAME AS DIFFUSER NECK SIZE. 8. FURNISH BRANCH RUNOUTS WITH VOLUME CONTROL DAMPERS. 9. ALL DUCTWORK SHALL BE GALVANIZED SHEETMETAL. THE AIR DISTRIBUTION COMPONENTS SHALL BE SEALED IN ACCORDANCE WITH SMACNA REQUIREMENTS. TWO INCH PRESSURE CLASS. 10. DUCT DIMENSIONS DO NOT INCLUDE ALLOWANCES FOR INSULATION. 11. DUCT INSULATION WRAP SHALL BE 1" FIBERGLASS WITH ALL SERVICE JACKET. INSTALL & SEAL ALL EDGES IN ACCORDANCE WITH MANUFACTURER'S REQUIREMENTS. 12. MOUNT DUCTWORK IN SALES AREA & BACK ROOMS TIGHT TO BOTTOM OF STRUCTURE UNLESS NOTED OTHERWISE. 13. PROVIDE FLEXIBLE DUCT CONNECTION IN DUCTWORK AT ALL EXPANSION/CONTRACTION JOINTS IN BUILDING. 14. FLEXIBLE DUCTWORK SHALL NOT EXCEED 8-0" AND 180 DEGREE TOTAL BEND. 15. SEGREGATE EXISTING DUCTWORK FROM NEW STORAGE & NEW SALES AREA. NO DUCTWORK PENETRATIONS SHALL PASS THROUGH NEW DEMISING WALL. REROUTE DUCTWORK IN RESPECTIVE AREA. 16. 12 12x10 EXHAUST DUCT UP TO ROOF-MOUNTED EXHAUST FAN. TRANSITION DUCT RISER TO MATCH CONNECTION SIZE REQUIRED AT EXHAUST FAN. FAN CONTROL BY DIV 16. NO DUCT SHALL PASS THROUGH FIRE WALLS, OR BE CONNECTED TO ANY METAL DUCT WITHIN 5'-0" FROM EITHER SIDE OF A FIRE WALL. 13 GR-2, EXHAUST GRILL, 8x8 NECK, 225 CFM, MOUNT GRILLE IN TOILET ROOM CEILING. 17. PROVIDE CONICAL TAPS FOR ROUND DUCT RUNOUTS & 45 DEGREE ENTRY FITTINGS FOR RECTANGULAR DUCT RUNOUTS. 14 GS-1, SUPPLY DIFFUSER, 12" DIA. NECK, 650 CFM. SEE DETAIL 1/M-2. 18. THERMOSTATS SHALL BE LOCATED GENERALLY AS SHOWN BUT THE EXACT LOCATION SHALL BE FIELD COORDINATED TO AVOID INTERFERENCE WITH COLUMN-MOUNTED OR WALL-MOUNTED WORK OR FINISHES. 15 GS-1, SUPPLY DIFFUSER, 8" DIA. NECK, 200 CFM. SEE DETAIL 1/M-2. 16 GS-1, SUPPLY DIFFUSER, 6" DIA. NECK, 50 CFM. SEE DETAIL 1/M-2. 17 CONCENTRIC SUPPLY & RETURN PLENUM PROVIDED WITH RTU. BALANCE TO SCHEDULED AIR FLOW. 18 OUTLINE OF EXISTING MEZZANINE. 19 REMOVE EXISTING SMALL ROOF-MOUNTED TOILET EXHAUST FAN AND EXHAUST DUCTWORK IN EXISTING TOILET ROOMS. FIELD VERIFY EXACT DUCT ROUTING & DEMOLITION REQUIREMENTS. 08/23/10 SCALE: 1/8" = 1'-0" 29 DUCT OFFSET TO MATCH DUCT RISER LOCATION. VERIFY REQUIRED OFFSET. 30 CONDENSER FOR SPLIT-SYSTEM SS-1. MOUNT UNIT ON ROOF. ANCHOR IN PLACE. SEE SPLIT-SYSTEM PIPING DETAIL 3/M-2. 31 EF-2, UPBLAST EXHAUST FAN. SEE DETAIL 8/M-2. 32 REMOVE EXISTING INTAKE LOUVER TO MAKE WAY FOR NEW COMPRESSORS. WHEN COMPRESSOR INSTALLATION IS COMPLETE, REPLACE INTAKE LOUVERS WITH NEW GRAVITY OPERATED GREENHECK MODEL #ECD-401 AIR INTAKE LOUVER. FIELD VERIFY EXACT SIZE REQUIRED(NOMINAL SIZE TO BE SAME AS EXISTING WALL OPENING). LOUVER TO BE COMPLETE WITH 1/4"X1/4" GALVANIZED MESH SCREEN OVER OPENING. 33 WALL THERMOSTAT. INTERLOCK WITH EXHAUST FAN EF-2. SET THERMOSTAT TO ENERGIZE FAN WHEN AMBIENT TEMPERATURE IN MEZZANINE REACHES 80 DEGREES F. ALEXANDER CITY, AL SCALE: 1/8" = 1'-0" 1612 MILLS SQUARE 2 MEZZANINE HVAC PLAN RJK DRAWN: FRONT CHECKED: NORTH RNC 18 RIGHT REAR 4 DATE: 15 STORE NUMBER PROJECT NUMBER 03510-01 SHEET TITLE HVAC PLAN SHEET NUMBER M-1 BY: HVAC SYMBOLS / NOTES DUCT ELBOW UP NOT USED 4 SUPPLY AIR/DIFFUSER H HUMIDITY SENSOR RETURN, EXHAUST, OR TRANSFER GRILLE DP DEWPOINT SENSOR SUPPLY AIR T THERMOSTAT EXHAUST AIR TS TEMPERATURE SENSOR ACOUSTIC LINED DUCT SD SMOKE DETECTOR SUPPLY REGISTER (SIDEWALL) POWER OR GRAVITY ROOF VENTILATOR-INTAKE RETURN GRILLE (SIDEWALL) AIR DISCHARGE OR SUPPLY EXHAUST GRILE (SIDEWALL) AIR INTAKE, EXHAUST, OR RETURN MITERED ELBOW WITH TURNING VANES RADIUS ELBOW ELECTRIC DUCT HEATER PLENUM RETURN WALL CONICAL TAP OFF ROUND DUCT 45 DEGREE ENTRY FITTING CONICAL TAP OFF RECTANGULAR DUCT MANUAL VOLUME CONTROL DAMPER SCALE: NONE UPBLAST ROOF EXHAUST FAN INSTALL FACTORY FURNISHED DRIP EDGE ON NON-RAIL SIDES ROOFTOP UNIT (SIDE VIEW) FACTORY INSTALLED DISCONNECT SWITCH. VOLUME DAMPER AT BRANCH TAKE-OFF. PROVIDE FACE OPERATED OPPOSED BLADE DAMPER IN PLACE OF VOLUME DAMPER AT DIFFUSER IN HARD CEILING AREAS. FASTEN EQUIPMENT BASE TO PRE-FABRICATED CURB WOOD NAILER SHEET METAL DUCT & ELBOW CURB SEALER FLEXIBLE DUCT NECK ROOFTOP UNIT (NON-RAIL SECTION) WOOD NAILER STRIP CONNECT FLEX DUCT DIRECTLY TO DIFFUSER 1/4" NEOPRENE FOAM GASKET INTAKE HOOD, PIPE HOOD, GAS VENT OR FAN CADMIUM FASTENERS SPACED PER MANUFACTURER SPEC. MINIMUM 2 PER SIDE. CEILING DIFFUSER OR EXHAUST/ RETURN GRILLE FASTEN EQUIPMENT BASE TO PRE-FABRICATED CURB (2) PLACES EACH SIDE OF UNIT W/ #12 TEK SCREWS FACTORY BUILT LINED ROOF CURB BY SAME MANUFACTURER AS EXHAUST FAN. "T"-BAR CEILING WITH SUPPORT BY GENERAL CONTRACTOR (TYPICAL) COUNTERFLASHING WOOD NAILER FACE ROOFING BORDER PRE-FABRICATED CURB TREATED WOOD BLOCKING BELOW CURB WELD CURB TO STRUCTURE BACKDRAFT DAMPER IN ROOF CURB DAMPER TRAY. TYPICAL CEILING DIFFUSER SCALE: NONE 2 NOT USED SCALE: NONE 1/4" NEOPRENE FOAM GASKET ROOFTOP UNIT (END VIEW) FASTEN EQUIPMENT BASE TO PRE-FABRICATED CURB SQUARE DUCT RISER TO EXHAUST FAN. DUCT SIZE TO MATCH DAMPER SIZE. AC-UNIT RAIL WOOD NAILER COUNTERFLASHING 5 EQUIPMENT ROOF CURB ROOFTOP UNIT OR FAN NOTES FACTORY INSTALLED DISCONNECT SWITCH. ROOF EXHAUST FAN NEOPRENE GASKET ATTACH MOUNTING BRACKET TO ROOF CURB BEFORE MOUNTING EQUIP. WOOD NAILER FILL OPENING AIR-TIGHT WITH FOAM INSULATION AFTER LINES ARE INSTALLED 20 GAGE GALVANIZED SHEET METAL HOOD TEK SCREW (TYPICAL) ATTACH MOUNTING BRACKET TO INSIDE TOP OF ROOF CURB AS SHOWN USING 4 TEK SCREWS. HURRICANE BRACKET. SEE BLOW-UP BELOW. CURB SEALER (AS SPECIFIED) UNISTRUT ANCHORED TO CURB. CLAMP DISCHARGE AND DRAIN LINES WITH HYDRO-ZORB OR CUSHA CLAMP PRE-FABRICATED CURB ROOF CURB WOOD NAILER STRIP AFTER MOUNTING EQUIPMENT ON ROOF CURB, ATTACH BOTTOM OF BRACKET TO BASE RAIL OF EQUIP. AS SHOWN USING 4 TEK SCREWS. CADMIUM FASTENERS SPACED PER MANUFACTURER SPEC. MINIMUM 2 PER SIDE HARDWARE PACKAGE: FACTORY BUILT LINED ROOF CURB BY SAME MANUFACTURER AS EXHAUST FAN SCALE: NONE 8" ROOF MEMBRANE & INSULATION. ROOF DECK 12" (4) 10 GAUGE STEEL ATTACHMENT BRACKETS MANUFACTURED BY AES-INC. PHONE: 800-786-0402. (32) #10 TEK SCREWS ROOF DECK CONDENSING UNIT PIPE HOOD SS 1 EQUIPMENT CURB SECTION (2) BRACKETS ON EACH LONG SIDE OF CURB, EQUALLY SPACED. SUCTION & LIQUID LINES, SIZE & INSTALL PER MANUFACTURER'S INSTRUCTIONS (TYPICAL) ROOF ALEXANDER CITY, AL SCALE: NONE 1612 MILLS SQUARE DOWNBLAST EXHAUST FAN DATE: ROOFTOP UNIT (RAIL SECTION) 8 CHECKED: SEE STRUCTURAL PLANS FOR SUPPORT RJK RNC TREATED WOOD BLOCKING BELOW CURB WELD CURB TO STRUCTURE 08/23/10 ROOFING PRE-FABRICATED CURB DRAWN: 18"X18" EXHAUST INTAKE WITH 1/4"X1/4" GALVANIZED MESH SCREEN OVER OPENING. TYPICAL ON ALL FOUR SIDES OF DUCT RISER. 1 SEE STRUCTURAL PLANS FOR SUPPORT CONDUIT BY DIVISION 16 2" DEEP DRIP PAN SEALED WATER TIGHT. PRELIMINARY NOT FOR BID OR CONSTRUCTION POWER OR GRAVITY ROOF VENTILATOR-EXHAUST REV. NUMBER: FIRST DIMENSION GIVEN IS OF SIDE SHOWN 1/4" NEOPRENE FOAM GASKET C "COMPANY NAME" 20XX ALL RIGHTS RESERVED MOTOR (DAMPER OR VALVE) DATE: M DESCRIPTION: DUCT ELBOW DOWN CERTIFICATION: WXD FLEXIBLE DUCT STORE NUMBER CONDUIT BY DIVISION 16 BRACKET LOCATIONS (TYPICAL OF 4) BACKDRAFT DAMPER IN ROOF CURB DAMPER TRAY PROJECT NUMBER 03510-01 SHEET TITLE RTU OR FAN SQUARE DUCT RISER TO EXHAUST FAN. DUCT SIZE TO MATCH DAMPER SIZE. FAN COIL UNIT MOUNTED ON WALL. INSTALL PER MANUFACTURER'S INSTRUCTIONS (TYPICAL) 2" DEEP DRIP PAN SEALED WATER TIGHT SS 1 SCREW LOCATIONS (TYPICAL OF 8) EXHAUST DUCT. SEE PLAN FOR SIZE NOTE: HEIGHT OF DRAIN & DISCHARGE LINES TO MATCH SPECIFIC SPACE FOR DISCHARGE CONDENSER. ALLOW TO DROP INTO INLET SHEET NUMBER EQUIPMENT PLAN WALL BRACKET BLOW-UP M-2 FLOOR 7 DOWNBLAST EXHAUST FAN SCALE: NONE HVAC SCHEDULES & DETAILS 6 EQUIP. HOLD DOWN BRACKETSCALE: NONE 3 SPLIT SYSTEM PIPING SCALE: NONE E C D 4. PROVIDE NEW DRY PENDENT HEADS IN INTERIOR FREEZERS & COOLERS. SEAL ESCUTCHEON VAPOR TIGHT W/ FROTH-PAK POLY- URETHANE FOAM PRIOR TO OPERATION OF REFRIGERATED SPACE 5. PROVIDE NEW SEMI RECESSED SPRINKLER HEADS IN ALL NEW ACOUSTIC CEILING. 6. ALL FIRE PROTECTION WORK TO BE EXECUTED IN STRICT CONFORMANCE WITH NFPA 13 & LOCAL CODES & AMENDMENTS. THE SYSTEM SHALL BE GUARANTEED FOR MINIMUM OF ONE (1) YEAR FROM THE DATE OF FINAL ACCEPTANCE BY THE OWNER/ARCHITECT. 7. SPRINKLER SYSTEM IS BASED ON A ORDINARY HAZARD CLASSIFICATION. 8. CONTRACTOR TO SECURE ALL NECESSARY PERMITS & APPROVALS FROM AUTHORITY HAVING JURISDICTION. DRY PENDENT SPRINKLER B SCALE: NONE 9. NEW SPRINKLER HEADS SHALL BE PLACED IN CENTER OF TILES WHERE SUSPENDED CEILING EXISTS. 10. COORDINATION WITH ALL OTHER TRADES IS REQUIRED PRIOR TO ANY INSTALLATION. SEE ARCHITECTURAL & STRUCTURAL DRAWINGS FOR EXACT CEILING SPACE AVAILABLE. 11. VISIT SITE PRIOR TO BIDDING TO CONFIRM LOCATIONS OF EXISTING FIRE MAINS & EXISTING BRANCH MAINS FOR INSTALLATION OF NEW HEADS AND DEMOLITION OF EXISTING HEADS. 12. SUBMIT SHOP DRAWINGS TO THE AUTHORITY HAVING JURISDICTION AND THE ARCHITECT. 13. PROVIDE WARRANTY FOR A MINIMUM TERM OF ONE YEAR OR IN ACCORDANCE WITH THE GENERAL CONDITIONS, WHICHEVER IS GREATER. 14. FURNISH & INSTALL ALL HANGERS & STEEL FABRICATIONS, OTHER THAN BUILDING STRUCTURE, REQUIRED FOR PROPER SUPPORT OF PIPING & EQUIPMENT. 15. SUPPORT OF PIPES WITH DIAMETER LARGER THAN 2-1/2 INCHES MAY REQUIRED MODIFICATION OF STRUCTURAL MEMBERS TO SUPPORT INCREASED LOADS. SUSPEND PIPING & EQUIPMENT SUPPORTED BY BUILDING STRUCTURE ONLY BY THOSE METHODS, AND ONLY AT THOSE LOCATIONS ACCEPTABLE. 16. DO NOT SUSPEND PIPING & EQUIPMENT OF ANY SIZE FROM THE ROOF DECK, EXCEPT WHERE SPECIFICALLY APPROVED BY STRUCTURAL ENGINEER. 16. WHERE A PIPE HANGER POINT IS NOT DIRECTLY BELOW A STRUCTURAL GIRDER, OR STEEL JOIST, PROVIDE SUPPLEMENTARY SUPPORTING STEEL FABRICATION TO BRIDGE BETWEEN STRUCTURAL MEMBERS TO RECEIVE THE HANGER. ATTACH SUPPLEMENTARY MEMBERS TO BUILDING STRUCTURE ONLY BY THOSE METHODS AND AT THOSE LOCATIONS. 18. ARRANGE FOR ALL INSPECTIONS, EXAMINATIONS & TESTS IN FULL CONFORMANCE WITH THE REQUIREMENTS OF ALL APPLICABLE CODES, NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARDS, AUTHORITIES HAVING JURISDICTION, THE OWNER'S INSURANCE COMPANY, AND THE OWNER'S FIRE PROTECTION CONSULTANT, AS NECESSARY TO OBTAIN COMPLETE AND FINAL ACCEPTANCE OF THE FIRE SPRINKLER SYSTEM. A 19. LEAVE ENTIRE SPRINKLER SYSTEM CLEAN IN EVERY RESPECT AT THE CONCLUSION OF THE WORK. C "COMPANY NAME" 20XX ALL RIGHTS RESERVED THE FIRE PROTECTION SYSTEM SHALL PROVIDE COVERAGE TO ENTIRE LEASE SPACE, SEE PLAN FOR LIMITS OF WORK, AND SHALL BE COMPATIBLE WITH THE ARCHITECTURAL CONTRACT DOCUMENTS LAYOUTS AND AVOID INTERFERENCE WITH WORK OF ALL OTHER TRADES IN THE BUILDING. PRELIMINARY NOT FOR BID OR CONSTRUCTION 3. DATE: SPRINKLER SYSTEM TO BE DESIGN/BUILD BY SPRINKLER CONTRACTOR DRAWING INDICATES LAYOUT OF REVISED TENANT SPACE. EXISTING HEADS & NEW HEADS REQUIRED MUST BE FIELD VERIFIED BY SPRINKLER CONTRACTOR . NEW SPRINKLER HEADS SHALL BE PROVIDED TO MATCH EXISTING IN CEILING AREAS, CONTRACTOR TO VERIFY QUANTITY & LOCATION OF HEADS AS PART OF DESIGN/BUILD CONTRACT. DESCRIPTION: CAULK ANNULAR SPACE WATERTIGHT BETWEEN DRY PENDENT SPRINKLER & COOLER PANEL PENETRATION RECESSED DRY PENDENT SPRINKLER F 2. DRY BARREL TO BE 18" MINIMUM HEIGHT FOR SPRINKLERS SERVING FREEZERS COOLER OR FREEZER PANEL G WORK IN THIS SECTION INCLUDES, BUT IS NOT NECESSARILY LIMITED TO, PROVIDING ALL DESIGN, CALCULATIONS, LABOR, MATERIALS, SUPERVISION, TESTING, PERMITS & APPROVALS REQUIRED TO DESIGN, INSTALL & OBTAIN FINAL ACCEPTANCE OF THE AUTOMATIC FIRE PROTECTION SPRINKLER SYSTEM COMPLETE IN ALL RESPECTS. REV. NUMBER: SEAL ESCUTCHEON VAPOR TIGHT W/ FROTH PAK POLYURETHANE FOAM PRIOR TO OPERATION OF REFRIGERATED SPACE 1 1. DRY BARREL TO BE 8" MINIMUM HEIGHT FOR SPRINKLERS SERVING COOLERS CERTIFICATION: TEE WITH PLUG BY: GENERAL NOTES WET MAIN 1 BACK ROOM 'B' 8 117 6 7 2 DRAWN: VESTIBULE 100 08/23/10 108 DATE: 109 RJK MEAT PREP CHECKED: MEAT COOLER RNC 2 SALES AREA PRODUCE COOLER FREEZER 110 101 113 1 PROVIDE SPRINKLERS & PIPING TO EXISTING FIRE PROTECTION SYSTEM TO ACCOMMODATE NEW CORRIDOR & NEW CEILING IN TOILET ROOMS. 2 PROVIDE SPRINKLERS & PIPING TO EXISTING FIRE PROTECTION SYSTEM TO ACCOMMODATE REVISIONS TO BACKROOM AREA. 3 PROVIDE DRY PENDENT SPRINKLERS & PIPING TO EXISTING FIRE PROTECTION SYSTEM TO ACCOMMODATE NEW FREEZER. SEE DETAIL 1/FP-1. 4 PROVIDE DRY PENDENT SPRINKLERS & PIPING TO EXISTING FIRE PROTECTION SYSTEM TO ACCOMMODATE NEW DAIRY COOLER. SEE DETAIL 1/FP-1. 5 PROVIDE DRY PENDENT SPRINKLERS & PIPING TO EXISTING FIRE PROTECTION SYSTEM TO ACCOMMODATE NEW PRODUCE COOLER. SEE DETAIL 1/FP-1. 6 PROVIDE DRY PENDENT SPRINKLERS & PIPING TO EXISTING FIRE PROTECTION SYSTEM TO ACCOMMODATE NEW MEAT COOLER. SEE DETAIL 1/FP-1. 7 PROVIDE DRY PENDENT SPRINKLERS & PIPING TO EXISTING FIRE PROTECTION SYSTEM TO ACCOMMODATE NEW MEAT PREP. SEE DETAIL 1/FP-1. 8 SPRINKLER CONTRACTOR SHALL MODIFY/ADD SPRINKLERS & PIPING TO EXISTING FIRE SPRINKLER SYSTEM AT SALES AREA & OFFICES IN SALES AREA. ADJUST SPRINKLERS TO ACCOMMODATE NEW WALL BETWEEN SALES AREA & BACKROOMS. 9 EXISTING FIRE DEPARTMENT CONNECTION. 10 EXTEND EXISTING FIRE PROTECTION SYSTEM TO PROTECT AREA UNDER FRONT CANOPY. PROVIDE DRY PIPE OR GLYCOL-FILLED SPRINKLER SYSTEM TO MEET REQUIREMENTS OF LOCAL CODES AND AUTHORITIES HAVING JURISDICTION. 5 BACK ROOM 'A' 8 111 2 9 PRODUCE PREP AREA 112 10 MEN 114 SAFE 3 102 1 OFFICE 103 BACK ROOM 'B' RECEIVING 116 2 WOMEN 115 117 1 4 STORE NUMBER 8 DAIRY COOLER 107 1612 MILLS SQUARE 3 PROJECT NUMBER 03510-01 8 BREAK ROOM SHEET TITLE 104 8 4 FIRE PROTECTION PLAN NORTH RIGHT REAR FRONT SHEET NUMBER FP-1 LEFT 2 FIRE SPRINKLER PLAN ALEXANDER CITY, AL KEYED NOTES SCALE: 1/8" = 1'-0" PERFORM DEMOLITION AS REQUIRED TO ACCOMMODATE THE NEW CONSTRUCTION. 3. FIELD VERIFY EXISTING CONDITIONS AND REPORT DISCREPANCIES AS SOON AS POSSIBLE TO THE ENGINEER. 4. REMOVE BRANCH CIRCUITS SERVING EQUIPMENT THAT HAS BEEN REMOVED. 5. REMOVE EQUIPMENT WHERE INDICATED. THIS MAY INCLUDE SWITCHGEAR, FEEDERS, LIGHTING FIXTURES, MOTOR CONTROLS, SAFETY SWITCHES, DISCONNECTS, AND WIRING DEVICES. 15 6. FOR DISCONNECTED AND REMOVED ITEMS, PERFORM THE FOLLOWING UNLESS NOTED OTHERWISE: a. REMOVE WIRING BACK TO ITS SOURCE. b. REMOVE EXPOSED CONDUIT AND BOXES BACK TO THE NEAREST OUTLET BOX REMAINING IN USE (CONCEALED CONDUIT AND BOXES MAY REMAIN). c. INSTALL BLANK COVERS ON ABANDONED FLUSH OUTLETS. d. CORRECT PANELBOARD SCHEDULE WHERE WIRING IS REMOVED BACK TO PANELBOARD. 7. REUSE SUITABLE MATERIAL WHEREVER POSSIBLE. MATERIALS NOT REUSED AND NOT WANTED BY THE TENANT WILL BECOME THE PROPERTY OF THE CONTRACTOR AND WILL BE REMOVED FROM THE SITE. MATERIALS TURNED OVER TO THE OWNER WILL BE STORED AS DIRECTED. PNL-RDP(E) 8. CUT OFF EXPOSED STUB-UPS FLUSH WITH FLOOR AND PATCH FLOOR AS REQUIRED. MDP(E) 9. SEE ARCHITECTURAL PLAN, FIXTURE PLANS, MECHANICAL AND REFRIGERATION PLANS FOR SCOPE OF DEMOLITION. PNL-EM(E) 10. REMOVE ALL ELECTRICAL EQUIPMENT, DEVICES, BOXES, ETC. IN OR ON EXISTING WALLS, CEILINGS OR FLOORS WHICH ARE BEING REMOVED. PROVIDE COVER PLATES AND PATCH WALL, CEILING AND FLOOR AS REQUIRED. 14 11. DISCONNECT EXISTING CASES, FIXTURES AND EQUIPMENT THAT ARE BEING REMOVED. 12. ALL EXISTING LIGHTING IS TO REMAIN UNLESS NOTED OTHERWISE. WIREWAY(E) PNL-PL(E) 300A DISC.(E) 14 PNL-PLA(E) 200A DISC.(E) 10 PNL-PLL(E) 14 14 1 13. REMOVE ALL UNUSED LOW VOLTAGE WIRING. PNL-PS(E) 14 100A DISC.(E) PNL-PMA(E) 11 PNL-PM(E) 13 PNL-PH(E) 12 ELECTRICAL DEMOLITION MEZZ. PLAN PRELIMINARY NOT FOR BID OR CONSTRUCTION 14 5 C "COMPANY NAME" 20XX ALL RIGHTS RESERVED 2. 17 DATE: MAINTAIN CONTINUITY OF SERVICE TO ALL ELECTRICAL UTILIZATION EQUIPMENT THAT REMAINS IN SERVICE. PROVIDE TEMPORARY WIRING AS REQUIRED. DESCRIPTION: 1. REV. NUMBER: J BY: GENERAL NOTES 14 SCALE: 3/32" = 1'-0" CERTIFICATION: PNL-A/C(E) KEYED NOTES 6 1 1 5 1 4 1. FOR EQUIPMENT OR FIXTURE OUTSIDE SAVE-A-LOT SPACE, DISCONNECT EQUIPMENT OR FIXTURE FROM SAVE-A-LOT ELECTRICAL SERVICE AND ABANDON IN PLACE. 2. NOT USED. 3. DISCONNECT AND REMOVE EXISTING GENERAL LIGHT FIXTURES, EMERGENCY LIGHT FIXTURES, EXIT SIGNS AND ALL ASSOCIATED WIRING IN THIS AREA. 4. DISCONNECT AND REMOVE EXISTING FLUORESCENT STRIP FIXTURES FOR THE CONSTRUCTION OF NEW DEMISING WALL. 5. DISCONNECT AND REMOVE EXISTING FLUORESCENT STRIP FIXTURES. 6. EXISTING LIGHT FIXTURES TO REMAIN. MAKE FULLY OPERATIONAL. 7. DISCONNECT AND REMOVE EXISTING EQUIPMENT AND ALL ASSOCIATED WIRING DEVICES, EXPOSED CONDUITS, BOXES, AND CORDS SERVING EXISTING EQUIPMENT. 8. NOT USED. NOT USED. 4 3 3 9. 7 7 10. RE-USE EXISTING PANEL "PLL" AND RE-LABEL AS "LA". 11. RE-USE EXISTING PANEL "PMA" AND RE-LABEL AS "LB". 12. RE-USE EXISTING PANEL "PH" AND RE-LABEL AS "LC". 13. RE-USE EXISTING PANEL "PM" AND RE-LABEL AS "LD". 5 5 14. DISCONNECT EXISTING PANEL AND ABANDON IN PLACE. 15. EXISTING ELECTRIC WATER HEATER TO REMAIN. 7 DATE: DRAWN: CHECKED: 7 3 08/23/10 17. COORDINATE WITH DIVISION 15 TO DISCONNECT AND REMOVE ANY WIRING ASSOCIATED WITH LOUVER AND ANY MECHANICAL OR HVAC EQUIPMENT IN THE MEZZANINE. MKQ PNL-CP(ER) 3 16. DISCONNECT AND REMOVE EXISTING PANEL. BER/BR 2 3 5 PNL-PD(E) 16 3 6 1612 MILLS SQUARE 3 7 3 7 ALEXANDER CITY, AL 7 STORE NUMBER 4 4 4 PROJECT NUMBER 03510-01 SHEET TITLE 1 1 ELECTRICAL DEMOLITION PLAN G F E D C B A REAR NORTH RIGHT FRONT SHEET NUMBER LEFT E-0 2 ELECTRICAL DEMOLITION PLAN SCALE: 1/8" = 1'-0" PERFORM DEMOLITION AS REQUIRED TO ACCOMMODATE THE NEW CONSTRUCTION. 3. FIELD VERIFY EXISTING CONDITIONS AND REPORT DISCREPANCIES AS SOON AS POSSIBLE TO THE ENGINEER. 4. REMOVE BRANCH CIRCUITS SERVING EQUIPMENT THAT HAS BEEN REMOVED. 5. REMOVE EQUIPMENT WHERE INDICATED. THIS MAY INCLUDE SWITCHGEAR, FEEDERS, LIGHTING FIXTURES, MOTOR CONTROLS, SAFETY SWITCHES, DISCONNECTS, AND WIRING DEVICES. 15 6. FOR DISCONNECTED AND REMOVED ITEMS, PERFORM THE FOLLOWING UNLESS NOTED OTHERWISE: a. REMOVE WIRING BACK TO ITS SOURCE. b. REMOVE EXPOSED CONDUIT AND BOXES BACK TO THE NEAREST OUTLET BOX REMAINING IN USE (CONCEALED CONDUIT AND BOXES MAY REMAIN). c. INSTALL BLANK COVERS ON ABANDONED FLUSH OUTLETS. d. CORRECT PANELBOARD SCHEDULE WHERE WIRING IS REMOVED BACK TO PANELBOARD. 7. REUSE SUITABLE MATERIAL WHEREVER POSSIBLE. MATERIALS NOT REUSED AND NOT WANTED BY THE TENANT WILL BECOME THE PROPERTY OF THE CONTRACTOR AND WILL BE REMOVED FROM THE SITE. MATERIALS TURNED OVER TO THE OWNER WILL BE STORED AS DIRECTED. PNL-RDP(E) 8. CUT OFF EXPOSED STUB-UPS FLUSH WITH FLOOR AND PATCH FLOOR AS REQUIRED. MDP(E) 9. SEE ARCHITECTURAL PLAN, FIXTURE PLANS, MECHANICAL AND REFRIGERATION PLANS FOR SCOPE OF DEMOLITION. PNL-EM(E) 10. REMOVE ALL ELECTRICAL EQUIPMENT, DEVICES, BOXES, ETC. IN OR ON EXISTING WALLS, CEILINGS OR FLOORS WHICH ARE BEING REMOVED. PROVIDE COVER PLATES AND PATCH WALL, CEILING AND FLOOR AS REQUIRED. 14 11. DISCONNECT EXISTING CASES, FIXTURES AND EQUIPMENT THAT ARE BEING REMOVED. 12. ALL EXISTING LIGHTING IS TO REMAIN UNLESS NOTED OTHERWISE. WIREWAY(E) PNL-PL(E) 300A DISC.(E) 14 PNL-PLA(E) 200A DISC.(E) 10 PNL-PLL(E) 14 14 1 13. REMOVE ALL UNUSED LOW VOLTAGE WIRING. PNL-PS(E) 14 100A DISC.(E) PNL-PMA(E) 11 PNL-PM(E) 13 PNL-PH(E) 12 ELECTRICAL DEMOLITION MEZZ. PLAN PRELIMINARY NOT FOR BID OR CONSTRUCTION 14 5 C "COMPANY NAME" 20XX ALL RIGHTS RESERVED 2. 17 DATE: MAINTAIN CONTINUITY OF SERVICE TO ALL ELECTRICAL UTILIZATION EQUIPMENT THAT REMAINS IN SERVICE. PROVIDE TEMPORARY WIRING AS REQUIRED. DESCRIPTION: 1. REV. NUMBER: J BY: GENERAL NOTES 14 SCALE: 3/32" = 1'-0" CERTIFICATION: PNL-A/C(E) KEYED NOTES 6 1 1 5 1 4 1. FOR EQUIPMENT OR FIXTURE OUTSIDE SAVE-A-LOT SPACE, DISCONNECT EQUIPMENT OR FIXTURE FROM SAVE-A-LOT ELECTRICAL SERVICE AND ABANDON IN PLACE. 2. NOT USED. 3. DISCONNECT AND REMOVE EXISTING GENERAL LIGHT FIXTURES, EMERGENCY LIGHT FIXTURES, EXIT SIGNS AND ALL ASSOCIATED WIRING IN THIS AREA. 4. DISCONNECT AND REMOVE EXISTING FLUORESCENT STRIP FIXTURES FOR THE CONSTRUCTION OF NEW DEMISING WALL. 5. DISCONNECT AND REMOVE EXISTING FLUORESCENT STRIP FIXTURES. 6. EXISTING LIGHT FIXTURES TO REMAIN. MAKE FULLY OPERATIONAL. 7. DISCONNECT AND REMOVE EXISTING EQUIPMENT AND ALL ASSOCIATED WIRING DEVICES, EXPOSED CONDUITS, BOXES, AND CORDS SERVING EXISTING EQUIPMENT. 8. NOT USED. NOT USED. 4 3 3 9. 7 7 10. RE-USE EXISTING PANEL "PLL" AND RE-LABEL AS "LA". 11. RE-USE EXISTING PANEL "PMA" AND RE-LABEL AS "LB". 12. RE-USE EXISTING PANEL "PH" AND RE-LABEL AS "LC". 13. RE-USE EXISTING PANEL "PM" AND RE-LABEL AS "LD". 5 5 14. DISCONNECT EXISTING PANEL AND ABANDON IN PLACE. 15. EXISTING ELECTRIC WATER HEATER TO REMAIN. 7 DATE: DRAWN: CHECKED: 7 3 08/23/10 17. COORDINATE WITH DIVISION 15 TO DISCONNECT AND REMOVE ANY WIRING ASSOCIATED WITH LOUVER AND ANY MECHANICAL OR HVAC EQUIPMENT IN THE MEZZANINE. MKQ PNL-CP(ER) 3 16. DISCONNECT AND REMOVE EXISTING PANEL. BER/BR 2 3 5 PNL-PD(E) 16 3 6 1612 MILLS SQUARE 3 7 3 7 ALEXANDER CITY, AL 7 STORE NUMBER 4 4 4 PROJECT NUMBER 03510-01 SHEET TITLE 1 1 ELECTRICAL DEMOLITION PLAN G F E D C B A REAR NORTH RIGHT FRONT SHEET NUMBER LEFT E-0 2 ELECTRICAL DEMOLITION PLAN SCALE: 1/8" = 1'-0" PROVIDE 0 DEGREE OR MINUS 20 DEGREE BALLAST. 3. PROVIDE 0 DEGREE BALLASTS IN ALL APPLICABLE EXTERIOR LIGHT FIXTURES. PROVIDE -20 DEGREE BALLASTS FOR EXTERIOR LIGHT FIXTURES IN AREAS WITH DESIGN TEMPERATURE BELOW 0 DEGREE F. 4. PROVIDE PLASTIC TUBE GUARD COVERS OVER ALL AREAS FOR FOOD PREPARATION AND OTHER OPEN AREAS AS REQUIRED BY HEALTH DEPARTMENT. 5. LAMP IS PROVIDED WITH FIXTURE. FURNISHED WITH BATTERY BACKUP, MINIMUM 90 MINUTES RUNNING TIME. 6. ALL LIGHT FIXTURES WITH THE DESIGNATION OF NL ARE NIGHT LIGHTS AND CIRCUITED UNSWITCHED, 24/7. 7. THE BRANCH CIRCUIT FEEDING THE EMERGENCY/EXIT LIGHTS SHALL BE THE SAME BRANCH CIRCUIT AS THAT SERVING THE NIGHT LIGHTING IN THE AREA AND SHALL BE CONNECTED AHEAD OF ANY LOCAL SWITCHES AND PROVIDED WITH A LOCK-ON FEATURE. 2. PROVIDE PLASTIC TUBE GUARD COVERS FOR STRIP FIXTURES USED IN ALL FOOD PREPARATION AREAS. 3. ALL DISCONNECTED ELECTRICAL WIRING TO BE TERMINATED ABOVE THE CEILING. 4. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH CODES AND ORDINANCES OF THE AUTHORITY HAVING JURISDICTION. 5. ALL EQUIPMENT AND MATERIALS SHALL BE UL LISTED AND LABELED FOR TYPES OF EQUIPMENT AND MATERIALS FOR WHICH LISTING AND LABELING IS AVAILABLE. 6. FURNISH AND INSTALL ALL LABOR AND MATERIALS REQUIRED FOR A COMPLETE ELECTRICAL SYSTEM. 7. MINIMUM WIRE SIZE SHALL BE #12 A.W.G. UNLESS NOTED OTHERWISE. ALL CONDUCTORS SHALL BE COPPER WITH "THWN" INSULATION UNLESS NOTED OTHERWISE. 8. ALL WIRE SHALL BE IN CONDUIT UNLESS NOTED OTHERWISE. 9. PVC CONDUIT SHALL NOT BE INTALLED ABOVE GRADE. ELECTRICAL CONTRACTOR TO VERIFY MOUNTING HEIGHT WITH SAVE-A-LOT SUPERVISOR. **LAMPS: I - INCANDESCENT; F - FLUORESCENT; MV - MERCURY VAPOR; MH - METAL HALIDE; Q - QUARTZ; HPS - HIGH PRESSURE SODIUM 10. TYPE MC CABLE WITH ALUMINUM ARMOR AND INTERNAL GROUND IS ACCEPTABLE FOR USE AS GENERAL BRANCH CIRCUIT WIRING FOR CIRCUITS 20 AMPERES OR LESS AND CONCEALED IN WALLS OR ABOVE SUSPENDED CEILING AND AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. 11. PROVIDE A SEPARATE GROUNDING CONDUCTOR FOR ALL FEEDERS AND BRANCH CIRCUITS. 12. CONDUCTORS FOR BRANCH CIRCUITS SHALL BE SIZED TO PREVENT VOLTAGE DROP EXCEEDING 3 PERCENT AT THE FARTHEST OUTLET OF POWER. WHERE VOLTAGE DROP IS DETERMINED TO EXCEED THIS VALUE THE CONTRACTOR SHALL INCREASE THE SIZE OF CONDUCTORS AS REQUIRED. BY: C "COMPANY NAME" 20XX ALL RIGHTS RESERVED 2. 1. DATE: PRICING MUST INCLUDE FREIGHT ALLOWED TO JOB SITE. DESCRIPTION: 1. GENERAL NOTES REV. NUMBER: LIGHT FIXTURE SCHEDULE NOTES 13. SEAL AROUND AND WITHIN CONDUITS PASSING THROUGH EXTERNAL WALLS, FLOORS, AND THOSE PASSING THROUGH WALLS, FLOORS, AND CEILING OF WALK-IN COOLERS AND FREEZERS. 14. CONTRACTOR TO BE RESPONSIBLE FOR ALL ELECTRICAL CONNECTIONS TO ALL EQUIPMENT UNLESS NOTED OTHERWISE. PNL-A/C(E) E E C C D D B B KEYED NOTES A A 13 13 2A/LA-16 2A/LA-16 X5 X5 LA-21 LA-21 NL NL 2A/LA-16 2A/LA-16 X5 X5 LA-21 LA-21 TYPE 5 TYPE 5 2A/LA-16 2A/LA-16 LA-22 LA-22 2A/LA-17 2A/LA-17 LA-22 LA-22 NL NL 3 3 2A 2A LA-21 LA-21 X5 X5 LA-21 LA-21 13E 13E LA-16 LA-16 13E 13E LA-16 LA-16 X1B X1B LA-19 LA-19 DL DL 2 2 54A 54A LA-24 LA-24 2A/LA-17 2A/LA-17 X5 X5 LA-21 LA-21 2A/LA-16 2A/LA-16 2A/LA-13 2A/LA-13 X5/LA-19 X5/LA-192A/LA-11 2A/LA-11 2A/LA-10 2A/LA-10 2A/LA-9 2A/LA-9 2A/LA-12 2A/LA-12 NL NL 3 3 2A 2A LA-19 LA-19 X5 X5 LA-21 LA-21 2A/LA-9 2A/LA-9 2A/LA-8 2A/LA-8 X5/LA-19 X5/LA-19 2A/LA-6 2A/LA-6 2A/LA-5 2A/LA-5 2A/LA-4 2A/LA-4 2A/LA-3 2A/LA-3 NL NL 3 3 2A 2A LA-19 LA-19 2A/LA-7 2A/LA-7 2A/LA-22 2A/LA-22 TYPE 6 TYPE 6 X5 X5 LA-21 LA-21 2A/LA-22 2A/LA-22 LA-18 LA-18 2B/LA-15 2B/LA-15 2A/LA-2 2A/LA-2 2A/LA-2 2A/LA-2 4A/LA-24 4A/LA-24 6. PROVIDE (3) 120V, 30A CIRCUIT FOR BUILDING MOUNTED EXTERIOR SIGNS. FIELD VERIFY EXACT LOCATION AND MAKE CONNECTION TO EMS THROUGH CONTACTORS. 7. PROVIDE (1) 3/4"C-2#10; 1#10 GND FOR PYLON SIGN. PROVIDE CONDUIT, J-BOXES, WIRING AND ALL REQUIRED CUTTING AND PATCHING. PROVIDE TIME CLOCK CONTROL NEARBY. VERIFY LOCATION. 8. NOT USED. 9. REUSE EXISTING CIRCUITS FOR SALES AREA LIGHTING TO THE EXTENT POSSIBLE. PROVIDE CIRCUITING THROUGH LIGHTING CONTACTORS PER CONTACTOR SCHEDULE AND LIGHTING CONTROL ZONE. 12. PROVIDE NEW STRIP FIXTURES WITH 0 DEGREE BALLAST FOR EXTERIOR LIGHTS. 2A/LA-9 2A/LA-9 X4 X4 LA-19 LA-19 4 4 2A/LA-4 2A/LA-4 X5 X5 LA-19 LA-19 X5 X5 LA-19 LA-19 X5 X5 LA-19 LA-19 2A/LA-13 2A/LA-13 2A/LA-12 2A/LA-12 2A/LA-11 2A/LA-11 2A/LA-10 2A/LA-10 2A/LA-9 2A/LA-9 2A/LA-8 2A/LA-8 2A/LA-7 2A/LA-7 X5 X5 LA-19 LA-19 2A/LA-6 2A/LA-6 2A/LA-5 2A/LA-5 2A/LA-4 2A/LA-4 PNL-CR PNL-CR 2A/LA-3 2A/LA-3 2B/LA-14 2B/LA-14 2B/LA-13 2B/LA-13 X5 X5 LA-19 LA-19 2B/LA-11 2B/LA-11 2B/LA-10 2B/LA-10 2B/LA-9 2B/LA-9 2B/LA-8 2B/LA-8 X5 X5 LA-19 LA-19 2B/LA-6 2B/LA-6 2B/LA-5 2B/LA-5 2B/LA-4 2B/LA-4 2B/LA-3 2B/LA-3 J J 4A/LA-24 4A/LA-24 12 12 OCCUPANCY SENSORS CONTRACTOR SHALL PROVIDE OCCUPANCY SENSOR SYSTEMS IN EACH AREA INDICATED ON THE PLANS AND SCHEDULED BELOW. EACH SYSTEM SHALL BE COMPLETE WITH ALL NECESSARY POWER PACK INTERFACE RELAYS (PP) AS REQUIRED FOR A COMPLETE OPERATING SYSTEM. CONTRACTOR SHALL INSTALL AND WIRE SENSOR SYSTEM PER THE MANUFACTURES WIRING DIAGRAMS. SET ALL SENSOR TIME DELAYS TO 15 MINUTES UNLESS NOTED OTHERWISE. SENSOR SYSTEM TYPES ARE AS FOLLOWS: 4A/LA-24 4A/LA-24 2B/LA-1 2B/LA-1 4A/LA-24 4A/LA-24 2A/LA-17 2A/LA-17 3 3 13E/LA-1 13E/LA-1 TYPE 1 TYPE 1 X5 X5 2B/LA-2 LA-19 2B/LA-2 13E/LA-1 LA-19 13E/LA-1 13E 13E LA-1 LA-1 2B/LA-7 2B/LA-7 2B/LA-12 2B/LA-12 LA-38,40,42 LA-38,40,42 6 6 7 7 2A/LA-1 2A/LA-1 2A/LA-2 2A/LA-2 2A/LA-14 2A/LA-14 2 2 4A/LA-24 4A/LA-24 3 3 X5 NL X5 LA-19 NL LA-19 LA-18 LA-18 4A/LA-24 4A/LA-24 4A/LA-24 4A/LA-24 2A/LA-3 2A/LA-3 1 1 2B 2B LA-18 LA-18 2A/LA-2 2A/LA-2 2A/LA-2 2A/LA-2 LA-36 LA-36 NL NL 3 3 2A 2A LA-19 LA-19 TYPE 5 TYPE 5 LA-18 LA-18 2A/LA-15 2A/LA-15 4A/LA-24 4A/LA-24 X5 X5 LA-19 LA-19 2A/LA-20 2A/LA-20 LA-18 LA-18 2A/LA-2 2A/LA-2 2A/LA-2 2A/LA-2 X7 X7 LA-19 LA-19 9 9 2A/LA-20 2A/LA-20 LA-22 LA-22 2A/LA-18 2A/LA-18 X1B X1B LA-19 LA-19 2A/LA-14 2A/LA-14 X5 X5 LA-19 LA-19 2A/LA-22 2A/LA-22 2A/LA-17 2A/LA-17 NL NL 3 3 2A 2A LA-21 LA-21 X5 X5 LA-19 LA-19 2A/LA-9 2A/LA-9 2A/LA-22 2A/LA-22 TYPE 6 TYPE 6 X5 X5 LA-21 LA-21 13 13 2B/LA-17 2B/LA-17 NL 3 NL 3 2A 2A LA-19 LA-19 TYPE 5 TYPE 5 NL NL 3 3 2A 2A LA-21 LA-21 2A/LA-17 2A/LA-17 UTILITY UTILITY TRANSFORMER(E) TRANSFORMER(E) 4 4 X4 X4 LA-17 LA-17 LA-22 LA-22 2A/LA-16 2A/LA-16 TYPE 5 TYPE 5 2A/LA-3 2A/LA-3 2A/LA-1 2A/LA-1 1 1 LA-16 (E) CONC LA-16 (E) CONC COOLER COOLER SLAB @ SLAB @ F.F.E. F.F.E. LA-16 LA-16 2A/LA-4 2A/LA-4 2A/LA-9 2A/LA-9 2A/LA-15 2A/LA-15 TYPE 5 TYPE 5 2A/LA-5 2A/LA-5 NL NL 3 3 2A 2A LA-19 LA-19 4A 4A LA-20 LA-20 LA-16 LA-16 1 1 LA-16 LA-16 2A/LA-6 2A/LA-6 NOT USED. 2A/LA-1 2A/LA-1 4A 4A LA-20 LA-20 X5 X5 LA-21 LA-21 4A 4A LA-20 LA-20 4A 4A LA-20 LA-20 2A/LA-16 2A/LA-16 2A/LA-8 2A/LA-8 X1B X1B LA-19 3 2A/LA-19 3 2A/LA-19 LA-19 4A 4A LA-20 LA-20 4A 4A LA-20 LA-20 2A/LA-17 2A/LA-17 2A/LA-9 2A/LA-9 X5/LA-19 X5/LA-19 2A/LA-16 2A/LA-16 (E) CONC (E) CONC FREEZER FREEZER SLAB @ -4" SLAB @ -4" BELOW BELOW F.F.E. F.F.E. 2A/LA-10 2A/LA-10 5. 13E/LA-1 13E/LA-1 13E 13E LA-1 LA-1 4A/LA-24 4A/LA-24 12 12 4A/LA-24 4A/LA-24 1. 360 DEGREE, STANDARD RANGE, I.R. TYPE, (NO P.P. REQUIRED), CEILING MOUNTED, SENSOR SWITCH # CMR-9. 2. INFRARED/ULTRA SONIC TYPE, (NO P.P. REQUIRED), CEILING MOUNTED, SENSOR SWITCH # CMR-PDT. 3. LOW TEMP/HIGH HUMIDITY TYPE, (NO P.P. REQUIRED), 360 DEGREE, CEILING MOUNTED SENSOR SWITCH # CMRB-9 LT. 4. WALL SWITCH, I. R. TYPE; (NO PP REQUIRED); WALL MOUNTED; SENSOR SWITCH #WSD-V. 5. WALL SWITCH TYPE TIMER; WATT STOPPER #TS-300. 6. 360 DEGREE, STANDARD RANGE, I.R. TYPE, 2 POLE (NO P.P. REQUIRED), CEILING MOUNTED, SENSOR SWITCH # CMR-9-2P. LEGENDS STORE NUMBER PROJECT NUMBER 03510-01 SHEET TITLE TYPE 1 TYPE 1 4 4 (N) NEW (E) EXISTING TO REMAIN (ER) EXISTING RELOCATED (R) REMOVE LIGHTING PLAN ALL OTHERS NEW UNLESS NOTED OTHERWISE. SHEET NUMBER E-1 2 LIGHTING PLAN SCALE: 1/8" = 1'-0" ALEXANDER CITY, AL X1B X1B LA-21 LA-21 NL NL 3 3 2A 2A LA-21 LA-21 2A/LA-13 2A/LA-13 PROVIDE EXTERIOR EMERGENCY LIGHT TO BE MOUNTED BY OR ABOVE THE EXIT DOORS. 11. NOT USED. 1 1 X5/LA-19 X5/LA-19 2A/LA-2 2A/LA-2 4. 08/23/10 (N) CONC (N) CONC 4 STOOP 4 STOOP X4 X4 LA-17 LA-17 2A/LA-14 2A/LA-14 X5/LA-19 X5/LA-19 2A/LA-7 2A/LA-7 PROVIDE A NIGHT LIGHT AND CONNECT TO THE NEAREST EMERGENCY CIRCUIT. NIGHT LIGHT SHALL REMAIN ON AT ALL TIMES AND SHALL NOT BE RUN THROUGH LIGHTING CONTACTOR LOCAL SWITCHES. DATE: 2A/LA-15 2A/LA-15 X5/LA-19 X5/LA-19 2A/LA-12 2A/LA-11 2A/LA-12 2A/LA-11 3. 1612 MILLS SQUARE X5 X5 LA-21 LA-21 INSTALL TYPE 'DL' FIXTURE AND PROVIDE REQUIRED RECEPTACLE. VERIFY AND COORDINATE EXACT LOCATION WITH SAL PROJECT MANAGER AND POWER PLAN. 10. NOT USED. 4A/LA-24 4A/LA-24 2A/LA-16 2A/LA-16 2. BER\BKM 2A/LA-16 2A/LA-16 MAKE CONNECTION TO INCANDESCENT LIGHT FIXTURES FURNISHED NIC. WITH COOLER AND FREEZER BOXES. DRAWN: 2A/LA-17 2A/LA-17 (E) CONC (E) CONC FREEZER FREEZER SLAB @ -4" SLAB @ -4" BELOW BELOW F.F.E. F.F.E. 1. MKQ F F CHECKED: G G CERTIFICATION: 15. FIXTURES SHOWN WITHOUT FIXTURE TYPE ARE EXISTING TO REMAIN. CIRCUIT THROUGH CONTACTOR PER CONTACTOR SCHEDULE. MAKE ALL EXISTING EXTERIOR AND INTERIOR FIXTURES THAT ARE TO REMAIN FULLY OPERATIONAL. 16. PROVIDE CEILING MOUNTED EMERGENCY FIXTURES FOR THE MAIN SALES AREA EXCEPT WHERE FIXTURE IS SHOWN AGAINST THE WALL OR COLUMNS. MOUNT WALL OR COLUMN MOUNTED FIXTURES PER LIGHT FIXTURES SCHEDULE. 3. ALL DISCONNECTED ELECTRICAL WIRING TO BE TERMINATED ABOVE THE CEILING. 4. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH CODES AND ORDINANCES OF THE AUTHORITY HAVING JURISDICTION. 5. ALL EQUIPMENTS AND MATERIALS SHALL BE UL LISTED AND LABELED FOR TYPES OF EQUIPMENTS AND MATERIALS FOR WHICH LISTING AND LABELING IS AVAILABLE. 6. FURNISH AND INSTALL ALL LABOR AND MATERIALS REQUIRED FOR A COMPLETE ELECTRICAL SYSTEM. 7. MINIMUM WIRE SIZE SHALL BE #12 A.W.G. UNLESS NOTED OTHERWISE. ALL CONDUCTORS SHALL BE COPPER WITH "THWN" INSULATION UNLESS NOTED OTHERWISE. 8. ALL WIRE SHALL BE IN CONDUIT UNLESS NOTED OTHERWISE. 9. PVC CONDUIT SHALL NOT BE INSTALLED ABOVE GRADE. 10. TYPE MC CABLE WITH ALUMINUM ARMOR AND INTERNAL GROUND IS ACCEPTABLE FOR USE AS GENERAL BRANCH CIRCUIT WIRING FOR CIRCUITS 20 AMPERES OR LESS AND CONCEALED IN WALLS OR ABOVE SUSPENDED CEILING AND AS APPROVED BY THE AUTHORITY HAVING JURISDICTION. 11. PROVIDE A SEPARATE GROUNDING CONDUCTOR FOR ALL FEEDERS AND BRANCH CIRCUITS. 12. CONDUCTORS FOR BRANCH CIRCUITS SHALL BE SIZED TO PREVENT VOLTAGE DROP EXCEEDING 3 PERCENT AT THE FARTHEST OUTLET OF POWER. WHERE VOLTAGE DROP IS DETERMINED TO EXCEED THIS VALUE THE CONTRACTOR SHALL INCREASE THE SIZE OF CONDUCTORS AS REQUIRED. 13. SEAL AROUND AND WITHIN CONDUITS PASSING THROUGH EXTERNAL WALLS, FLOORS, AND THOSE PASSING THROUGH WALLS, FLOORS, AND CEILING OF WALK-IN COOLERS AND FREEZERS. 14. CONTRACTOR TO BE RESPONSIBLE FOR ALL ELECTRICAL CONNECTIONS TO ALL EQUIPMENT UNLESS NOTED OTHERWISE. VERIFY LOADS ON EXISTING CIRCUITS AND PANELS BEFORE ADDING TO THEM. DO NOT OVERLOAD PANELS. CIRCUIT NUMBERS SHOWN ARE TO INDICATE CIRCUITING INTENTION, USE AVAILABLE CIRCUITS AND PROVIDE NEW BREAKERS AS NEEDED. UPDATE PANEL DIRECTORIES. CERTIFICATION: 15. C "COMPANY NAME" 20XX ALL RIGHTS RESERVED PROVIDE WEATHER PROOF, GFI RECEPTACLES IN COOLERS, FREEZERS, AND MEAT PREP AREAS. DATE: 2. DESCRIPTION: BRANCH CIRCUIT WIRING IS NOT SHOWN. PROVIDE BRANCH CIRCUIT WIRING AS REQUIRED PER N.E.C., NOTES, SPECIFICATIONS, AND PANEL SCHEDULES. REV. NUMBER: 1. BY: GENERAL NOTES G F E C D B A CR-26 LB-1 D 5. PROVIDE JUNCTION BOXES, CONDUITS AND PULL-STRING REQUIRED FOR THERMOSTAT OR TEMPERATURE SENSOR. VERIFY AND COORDINATE EXACT LOCATION AND REQUIREMENTS WITH MECHANICAL (DIVISION 15) CONTRACTOR AND SAVE-A-LOT PROJECT MANAGER. 6. PROVIDE DUPLEX RECEPTACLE FOR PRODUCE CASE MISTING SYSTEM AT 60" A.F.F. COORDINATE EXACT MOUNTING LOCATION WITH SAL PROJECT MANAGER, PLUMBING AND MISTING SYSTEM VENDOR. 7. PROVIDE (1) WEATHER PROOF RECEPTACLE WITH ISOLATED GROUND AT 48" A.F.F. FOR UPC SCALE AND PRINTER AND (1) WEATHER PROOF, GFI RECEPTACLE AT 48" A.F.F. FOR MEAT WRAPPER. IG RECEPTACLE SHALL HAVE GFI BREAKER. VERIFY EXACT LOCATION WITH SAL PROJECT MANAGER. 8. PROVIDE GFI RECEPTACLE FOR WRAPPING EQUIPMENT IN PRODUCE PREP. VERIFY EXACT LOCATION AND HEIGHT WITH SAL PROJECT MANAGER. 9. PROVIDE RECEPTACLE FOR PALLET JACK BATTERY CHARGER. FIELD VERIFY EXACT LOCATION AND MOUNTING HEIGHT. 10. PROVIDE WEATHER PROOF PUSHBUTTON FOR DOOR BELL MOUNTED AT 6'-0" ABOVE GRADE. 2 11. PROVIDE VIBRATONE DOOR BELL AND REQUIRED CONTROL WIRING. MOUNT AS HIGH AS POSSIBLE. SEE ALSO OFFICE ELEVATION DETAIL 5/E-4. 22 AC 01 18 12. NOT USED. LB-4 13. PROVIDE J-BOX, CONDUIT, AND WIRING FOR DETEX DOOR ALARM. SEE DETAIL 6/E-4. VERIFY WITH PROJECT MANAGER. CR-9 J J CR-10 LB-3,WP, 48"AFF 14. PROVIDE RECEPTACLES WITH (2) CIRCUITS DEDICATED FOR BREAK ROOM: (1) FOR REFRIGERATOR AND (1) FOR MICROWAVE. VERIFY AND COORDINATE EXACT LOCATIONS WITH SAL PROJECT MANAGER. 15. PROVIDE RECEPTACLE FOR DOCK LIGHT FIXTURE. VERIFY MOUNTING HEIGHT WITH SAVE A LOT PROJECT MANAGER. 16. NOT USED. 17. NOT USED. 18. REUSE EXISTING CIRCUIT AND WIRING FOR AUTOMATIC DOOR TO EXTEND POSSIBLE. REFEED FROM EXISTING TO REMAIN ELECTRICAL PANEL AS REQUIRED AND AS SHOWN ON PLAN. 19. PROVIDE XLERATOR MODEL XL-W HAND DRYER AND CIRCUIT AS SHOWN. 20. PROVIDE GFI RECEPTACLE FOR ELECTRIC WATER COOLER. COORDINATE LOCATION WITH DIVISION 15. 21. NOT USED. 22. MAKE CONNECTION TO FACTORY MOUNTED RECEPTACLE ON ROOF TOP UNIT. 23. PROVIDE THE FOLLOWING AT EACH ROOFTOP A/C UNIT: A. 3/4" CONDUIT STUB FROM A/C UNIT THROUGH THE ROOF TO THE BOTTOM OF ROOF STRUCTURE. PROVIDE PLASTIC BUSHING ON OPEN END OF CONDUIT. VERIFY AND COORDINATE WITH EMS CONTRACTOR, PROJECT MANAGER AND LANDLORD. B. 1/2" CONDUIT STUB FROM A/C TEMPERATURE SENSOR TO BOTTOM OF ROOF STRUCTURE. PROVIDE PLASTIC BUSHING ON OPEN END OF CONDUIT. VERIFY AND COORDINATE WITH EMS CONTRACTOR, PROJECT MANAGER AND LANDLORD. 18 CR-21 CR-21 J J 3 LB-8 1 2 LB-31 CR-25 (E) CONC COOLER SLAB @ F.F.E. J PP J CR-2 CR-1 2 LB-33 J PP J CR-4 CR-3 2 CR-5 J PP J CR-6 LB-35 20 LB-21 GFI LB-19 22 19 J LB-13 8 LB-9 UTILITY TRANSFORMER(E) J AC 02 22 J 5 AC 03 2 LB-37 J PP J CR-8 CR-7 LB-4 3 LB-4 5 PNL-CR GFI LB-15 LB-18 11 10 23 23 LB-14 13 J STORE NUMBER J LB-17 19 SS 01B SS 01A LB-27 PROJECT NUMBER 03510-01 EF 01 SHEET TITLE CR-29 15 LB-20 9 LB-11 08/23/10 5 23 LB-1,WP, 48"AFF PROVIDE RECESSED RECEPTACLE FOR CUSTOMER AWARENESS. VERIFY EXACT LOCATION WITH SAL PROJECT MANAGER PRIOR TO INSTALLATION. SUPPORT BOX FROM STRUCTURE INDEPENDENT OF CEILING. 48"A.F.F. CR-33 CR-29 14 48"A.F.F. CR-31 4 POWER PLAN SHEET NUMBER E-2 2 LIGHTING PLAN SCALE: 1/8" = 1'-0" ALEXANDER CITY, AL MT 01 GWH 01 7 J CR-25 D 4. DATE: CR-25 4 LB-3,WP, 48"AFF MT 02 PROVIDE RECEPTACLE FOR ICE MERCHANDISER. VERIFY LOCATION WITH SAL PROJECT MANAGER. VERIFY EXACT POWER REQUIREMENT AND RECEPTACLE TYPE WITH VENDOR PRIOR TO INSTALLATION. 1612 MILLS SQUARE (E) CONC FREEZER SLAB @ -4" BELOW F.F.E. 3. LB-6 CR-27 4 (N) CONC STOOP LB-14 13 J PROVIDE TWO-CHANNEL POWER POLE AT CHECKSTANDS FOR POWER AND COMMUNICATION WIRING. VERIFY LOCATIONS WITH SAL PROJECT MANAGER. MKQ BL 01 2. CHECKED: 1 6 PROVIDE WIRING FOR (2) ADDITIONAL FUTURE CHECKSTAND. COIL WIRE AND SECURE ABOVE THE CEILING FOR FUTURE USE. DRAWN: (E) CONC FREEZER SLAB @ -4" BELOW F.F.E. 1. BER/BR KEYED NOTES LB-2 SCALE: NONE 1 (1) 2-CONDUCTOR SHIELDED CABLE (#18 AWG OR LARGER) CONDUCTOR (BLACK & WHITE) - FOR TEMPERATURE SENSOR. 4. (2)#14 AWG CONDUCTORS SHIELDED CABLE SHALL BE COLOR CODED AS FOLLOWS:(2) RED - DRY CONTACT FOR FAN CONTROL. 5. MAGNETIC SWITCHE SHALL BE PROVIDED WITH EMCC/ECP. THE SWITCH SHALL BE MOUNTED TO THE OUTSIDE OF FREEZER ABOVE DOOR OPENING ON LATCH SIDE. MOUNT MAGNET TO DOOR 6. ALL CONTROL WIRE SHALL BE STRANDED. 7. ALL CONTROL WIRING FOR CASES AND WALK-INS SHALL TERMINATE AT THE REMOTE MANIFOLDS. 8. ALL CONDUIT FOR REFRIGERATED CASES SHALL BE 1". HOLD SALES AREA STUB-UPS TO WITHIN 1" OF DIMENSION. SEE REFRIGERATION DRAWINGS FOR DIMENSIONS. 9. ALL ELECTRICAL WIRING SHALL BE DONE IN STRICT ACCORDANCE WITH THE N.E.C. NO COLOR CHANGES IN WIRE RUNS OR MISLABELED CIRCUITS WILL BE ACCEPTED. ALL WIRING SHALL BE DONE ACCORDING TO SAVE-A-LOT SPECIFICATIONS. 10. PROVIDE THE NECESSARY INTERCONNECTING WIRES AND CONDUIT BETWEEN REFRIGERATION SYSTEM AND THE AIR-COOLED CONDENSERS. 11. PROVIDE THE NECESSARY INTERCONNECTING WIRES AND CONDUIT BETWEEN THE REFRIGERATION SYSTEMS AND THE ATTACHED REFRIGERATED LOADS. 12. MOUNT AND INSTALL ONE TEMPERATURE SENSOR PER WALK-IN COOLER AND FREEZER. NOTE THAT THESE SENSORS WILL BE SUPPLIED FROM FACTORY (SHIPPED LOOSE) FOR FIELD INSTALLATION. (EXCEPTION: CASE SENSOR WILL BE FACTORY MOUNTED.) 13. PROVIDE THE NECESSARY INTERCONNECTING WIRES BETWEEN THE REFRIGERATION SYSTEM AND TEMPERATURE SENSORS MOUNTED IN EACH REFRIGERATED CASE. CASE SENSORS WILL BE FACTORY MOUNTED. NOTE THAT ONLY BELDEN #8762 OR EQUIVALENT CABLE SHALL BE USED TO COMPLETE THIS CONNECTION. THE BARE GROUND SHIELD, OR DRAIN WIRE, SHALL ONLY BE CONNECTED AT CONTROL PANEL DOOR REFRIGERATION SYSTEM. 14. PROVIDE THE NECESSARY CONNECTING WIRES BETWEEN THE REFRIGERATION SYSTEM AND KLIXONS MOUNTED IN CASES AND UNIT COOLER/FREEZER. KLIXONS ARE TO BE WIRED TO THE DIGITAL INPUTS ON THE CONTROLLER. KLIXONS WILL BE USED FOR TEMPERATURE TERMINATION OF DEFROST. 15. PROVIDE THE NECESSARY INTERCONNECTING WIRES BETWEEN EACH OF THE REFRIGERATION SYSTEMS AND A LOCATION TO BE DETERMINED BY SAVE-A-LOT, LTD., FOR ESTABLISHING AN IN STORE ALARM. 16. E.C. SHALL INSTALL HEAT TRACE MATERIAL SUPPLIED BY REFRIGERATION CONTRACTOR ON MEAT COOLER AND FREEZER CONDENSATE LINES. 17. VERIFY FACTORY SETTING ON WIRING ROTATION OF EACH COMPRESSOR. 18. PROVIDE ASSISTANCE TO REFRIGERATION CONTRACTOR FOR START UP OF ALL REFRIGERATION ELECTRICAL EQUIPMENT. 19. IF HVAC AND LIGHTING IS CONTROLLED BY THE REFRIGERATION CONTROLLER, COORDINATE INSTALLATION AND FINAL TERMINATION WITH ENERGY MANAGEMENT CONTRACTOR. PARTS WILL BE FURNISHED BY SAVE-A-LOT WITH THE EXCEPTION OF COMMUNICATION INTERFACE BOARD IF REQUIRED. 20. ALL DISCONNECTED ELECTRICAL WIRING SHALL BE TERMINATED ABOVE THE CEILING. PNL-A/C(E) G G FF E E C C D D B B DATE: 3. C "COMPANY NAME" 20XX ALL RIGHTS RESERVED 208V, 3PH MCA = 28.9 AMP MOCP = 35 AMP 2 ANTI-SWEAT HEATER CIRCUITS TO BE 2 WIRE, 1 HOT AND 1 NEUTRAL. MARK NEUTRAL WITH PROPER PANEL LETTER AND CIRCUIT NUMBER. RUN CIRCUITS THROUGH ANTI-SWEAT PANEL. DESCRIPTION: WP 2. REV. NUMBER: CONDENSER 9 VERIFY AND COORDINATE ALL REFRIGERATION EQUIPMENTS, ELECTRICAL REQUIREMENTS AND ROUGH-IN INFORMATION WITH REFRIGERATION EQUIPMENT SUPPLIER. CERTIFICATION: WP 1. BY: GENERAL NOTES A A KEYED NOTES (E) (E) CONC CONC FREEZER FREEZER SLAB SLAB @ @ -4" -4" BELOW BELOW F.F.E. F.F.E. 1 1 TS TS TS TS (N) (N) CONC CONC STOOP STOOP AA 22 TS TS PROVIDE THE FOLLOWING FOR EACH CONDENSER: (1) 1/2" CONDUIT STUB FROM EACH CONDENSER CONTROL PANEL THROUGH THE ROOF TO THE BOTTOM OF THE ROOF STRUCTURE WITH PLASTIC BUSHING ON OPEN ENDS (1) 3/4" CONDUIT WITH (2)#18 AWG (SHIELDED BELDEN #8760 CABLE OR EQUIVALENT) FROM COMPRESSOR RACK CONTROLLER TO EACH CONDENSER FOR COMMUNICATIONS. 3. PROVIDE 1/2" STUB-UP FROM ALARM LOGGER PANEL OF THE ENERGY MANAGEMENT SYSTEM IN THE MANAGER'S OFFICE TO THE BOTTOM OF ROOF STRUCTURE. PROVIDE PLASTIC BUSHING ON OPEN ENDS OF CONDUIT. 4. NOT USED. 5. NOT USED. 6. NOT USED. 7. NOT USED. 8. PROVIDE CEILING MOUNTED WEATHERPROOF GFI RECEPTACLE FOR CONDENSATE LINE HEAT TAPE NEAR THE DRAIN END OF EVAPORATOR COILS. MAKE REQUIRED CONNECTION TO DOOR HEATER. COORDINATE WITH PLUMBING CONTRACTOR AND PROJECT MANAGER. 9. PROVIDE 208 V, 3 PHASE, 60 AMP WEATHER PROOF DISCONNECT, 3/4"C-3#8; 1#10 GND BRANCH CIRCUIT AND WIRING FROM COMPRESSOR RACK TO CONDENSER. CONNECT WEATHER PROOF GFI RECEPTACLE AS SHOWN. VERIFY AND COORDINATE EXACT REQUIREMENT, WIRING AND LOCATION WITH REFRIGERATION CONTRACTOR AND SAVE-A-LOT PROJECT MANAGER. TS TS AA 11 AA 2B 2B AA 44 AA 55 TS TS BB 16 16 TS TS BB 15 15 2 2 TS TS DATE: JJ TS TS MKQ TS TS 08/23/10 LB-41 LB-41 CHECKED: JJ 2. BER/BR 88 TS TS PROVIDE POWER FOR DAIRY COOLER DOOR HEATERS AND DOOR LIGHTS. DRAWN: (E) (E) CONC CONC FREEZER FREEZER SLAB SLAB @ @ -4" -4" BELOW BELOW F.F.E. F.F.E. TS TS 1. TS TS JJ TS TS BB 10 10 (E) (E) CONC CONC JCOOLER JCOOLER SLAB SLAB @ @ F.F.E. F.F.E. JJ TS TS AA 33 TS TS 3 3 UTILITY TRANSFORMER(E) LD-3 LD-3 ALP ALP PNL-CR TS TS JJ TS TS TS TS JJ TS TS TS TS TS TS BB 14 14 AA 77 TS TS 33 STORE NUMBER TS TS BB 13 13 PROJECT NUMBER 03510-01 TS TS AA 88 JJ LC-36,38 LC-36,38 JJ 11 TS TS BB 12 12 TS TS TS TS TS TS JJ BB 11 11 TS TS TS TS JJ AA 99 TS TS SHEET TITLE TS TS JJ 4 4 POWER PLAN REAR REAR NORTH NORTH RIGHT RIGHT FRONT FRONT SHEET NUMBER E-3 LEFT LEFT 2 REFRIGERATION POWER PLAN SCALE: 1/8" = 1'-0" ALEXANDER CITY, AL TS TS 1612 MILLS SQUARE 88 AA 66 LB-39 LB-39 2. PROVIDE 1" EMPTY CONDUIT WITH PULLSTRING, JUNCTION BOXES AND COVER PLATES IN THE OFFICE FOR CCTV WIRING BY OTHERS. CONDUIT IS TO RUN CONCEALED IN THE OFFICE WALL AND EXIT THE WALL WITHIN THE ACCESSIBLE CEILING SPACE ABOVE THE OFFICE. 3. PROVIDE (1) DUPLEX RECEPTACLE LOCATED 8'-0" ABOVE FINISHED FLOOR FOR CCTV EQUIPMENT. VERIFY LOCATION WITH THE SAVE-A-LOT PROJECT MANAGER PRIOR TO INSTALLATION. 4. PROVIDE ONE (1) DUPLEX RECEPTACLE, 3/4"C WITH PULL STRING, JUNCTION BOX AND COVER PLATE AT 6'-4" ABOVE FINISHED FLOOR ON THE SIDEWALL WITH SHELVING FOR MUSIC AND INTERCOM SYSTEMS. VERIFY LOCATION WITH THE SAVE-A-LOT PROJECT MANAGER PRIOR TO INSTALLATION. 5. PROVIDE DUPLEX RECEPTACLE AT 48" A.F.F. FOR EMPLOYEE TIME-CLOCK.VERIFY. COORDINATE EXACT LOCATION AND EXACT HEIGHT WITH SAVE-A-LOT PROJECT MANAGER. 6. PROVIDE FIVE (5) OVERRIDE SWITCHES FOR CONTACTORS FOR STORE LIGHTING AT 6'-0" ABOVE FINISHED FLOOR. LABEL TWO (2) SWITCHES "SALES AREA LIGHTING" AND TWO (2) "BACK AREA AND RECEIVING LIGHTING", AND ONE (1) "CASE LIGHTING". WIRE SWITCHES TO OVERRIDE ENERGY MANAGEMENT SYSTEM CONTROL. 7. CONNECT VIBRATONE TO VIBRATONE UNIT AND PUSHBUTTON IN RECEIVING AREA. 8. FLUSH MOUNT ELECTRICAL PANEL "CR". COORDINATE LOCATION WITH SAVE-A-LOT PROJECT MANAGER AND FURNITURE LAYOUT SO THAT MINIMUM 3' IN FRONT AND 30" WIDE OF WORKING SPACE IS ALLOWED. 9. PROVIDE J-BOX, COVER PLATE AND 3/4"C WITH PULLSTRING TO ACCESSIBLE CEILING FOR COMMUNICATION WIRING BY OTHERS. FINISH FLOOR 6 10 4"X4" JUNCTION BOX 8" A.F.F. CR-13 HINGE SIDE RIGID STEEL CONDUIT 3/4" MINIMUM 1'-6" 6'-0" 4"X4" BOX SECURITY 88" A.F.F. (TYPICAL FOR 2) 6'-8" 3/4" CONDUIT IN MASONRY WALL FLUSH COUPLING 4"X4" BOX FIRE PULL STATION 48" A.F.F. 1 OFFICE ELEVATION SCALE: 1/4" = 1'-0" 3 CONDUIT STUB-UP SCALE: NONE 10. PROVIDE BOXES, CONDUITS AND PULL-STRING REQUIRED FOR THERMOSTAT. VERIFY AND COORDINATE EXACT LOCATION AND REQUIREMENTS WITH MECHANICAL (DIVISION 15) CONTRACTOR AND SAVE-A-LOT PROJECT MANAGER. 11. PROVIDE POWER AND REQUIRED CONDUIT FOR REFRIGERATION ALARM LOGGER PANEL FURNISHED BY OTHERS (N.I.C). SEE 1/E-1.3. VERIFY AND COORDINATE LOCATION WITH REFRIGERATION CONTRACTOR AND EMS CONTRACTOR. 8'-0" NOTE: DO NOT RUN CONDUIT HORIZONTALLY IN WALL USED AS RETURN AIR PLENUMS. VERIFY RETURN AIR WALLS LOCATIONS WITH MECHANICAL. CR-22 IG 4"X4" JUNCTION BOX FOR TIME DELAY BAR 36" A.F.F. (MOUNT INSIDE THE DOOR JAMB) MOUNT ON HINGE SIDE OF DOOR CR-15 IG STUD WALL IG CR-15 CR-18 CR-13 12. NOT USED. 1'-6" 9 2 DETEX HARDWARE C "COMPANY NAME" 20XX ALL RIGHTS RESERVED PROVIDE (2) 3/4" EMPTY CONDUITS WITH PULL STRINGS FOR SECURITY WIRE AT THE SAFE. CONCEAL THE CONDUIT IN WALL AND STUB OUT ABOVE CEILING. VERIFY LOCATION WITH THE SAVE-A-LOT PROJECT MANAGER PRIOR TO INSTALLATION. DATE: 1. DESCRIPTION: 7 REV. NUMBER: PLUMB CENTERLINE RIGID STEEL OR PVC CONDUIT KEYED NOTES BY: KN CR-20 13. NOT USED. 14. PROVIDE RECEPTACLES AND POWER FOR FIRE ALARM, TELEPHONE BOARD, AND SECURITY SYSTEMS. SEE DETAIL 8/E-4. CONDUIT STUB-OUT CONDUIT CONCEALED IN WALL 15. PROVIDE A CONVENIENCE RECEPTACLE FOR COMPRESSOR ROOM. FLEXIBLE CONDUIT 6 SECURITY CONDUIT SCALE: NONE 2 OFFICE ELEVATION SCALE: 1/4" = 1'-0" 2" REFRIGERATED CASE WIREWAY 17. PROVIDE THE FOLLOWING AT EACH ROOFTOP A/C UNIT: A. 3/4" CONDUIT STUB FROM A/C UNIT THROUGH THE ROOF TO THE BOTTOM OF ROOF STRUCTURE. PROVIDE PLASTIC BUSHING ON OPEN END OF CONDUIT. VERIFY AND COORDINATE WITH EMS CONTRACTOR, PROJECT MANAGER AND LANDLORD. B. 1/2" CONDUIT STUB FROM A/C TEMPERATURE SENSOR TO BOTTOM OF ROOF STRUCTURE. PROVIDE PLASTIC BUSHING ON OPEN END OF CONDUIT. VERIFY AND COORDINATE WITH EMS CONTRACTOR, PROJECT MANAGER AND LANDLORD. CERTIFICATION: REFRIGERATED CASE 16. MAKE CONNECTION TO FACTORY MOUNTED RECEPTACLE ON ROOF TOP UNIT. 18. REFEED EXISTING ELECTRIC WATER HEATER TO EXISTING PANEL TO REMAIN. RE-USE EXISTING FEEDER TO THE EXTENT POSSIBLE. PROVIDE NEW AS REQUIRED. FIRE SECURITY TROUGH 6" x 6" x 36" CR-13 20. PROVIDE 3/4" CONDUIT STUB THROUGH ROOF TO THE BOTTOM OF ROOF STRUCTURE FOR TEMPERATURE AND LIGHT LEVEL SENSOR. STUB CONDUIT 36" HIGH ABOVE FINISHED ROOF. 14"W x 12"H 11"W x 13"H 21. PROVIDE (2) 1 1/2" CONDUIT STUB UPS WITH PULL-STRINGS OUT OF THE TOP OF ENVIRONMENTAL CONTROL PANEL (ECP) TO THE BOTTOM OF ROOF STRUCTURE FOR LOW VOLTAGE CONTROL AND COMMUNICATION WIRING. PROVIDE PLASTIC BUSHING ON OPEN ENDS OF CONDUIT. VERIFY AND COORDINATE EXACT LOCATION WITH REFRIGERATION CONTRACTOR AND PROJECT MANAGER. 1'-6" SCALE: NONE GEMINI 9600 3'-6" 10 DETEX POWER SUPPLY FIRE LITE 9200 19. PROVIDE A NIGHT LIGHT AND CONNECT TO THE NEAREST EMERGENCY CIRCUIT. NIGHT LIGHT SHALL REMAIN ON AT ALL TIMES AND SHALL NOT BE RUN THROUGH LIGHTING CONTACTOR LOCAL SWITCHES. CR-15 FIRE LITE POWER SUPPLY 15"W x 15"H NL 19 2A LA-21 2A/LA-15 17 3/4" PLYWOOD BACKBOARD 3 OFFICE ELEVATION 24"W x 14"H 4 CR-22 19 1 2 7 2A/LA-15 SCALE: 1/4" = 1'-0" DRAWN: 2 OFFICE ELEVATION 08/23/10 4 DATE: 2A/LA-16 MKQ 2A/LA-15 CR-13 CHECKED: 2A/LA-16 BER/BKR X5 LA-21 1'-6" 6'-8" 1 IG 18" A.F.F. 4'-0" 2A LA-21 22. PROVIDE (3) 1-1/2" CONDUIT STUB UPS WITH PULL-STRINGS FROM EACH DANFOSS REFRIGERATION RACK CONTROL PANEL TO THE BOTTOM OF ROOF STRUCTURE (1) FOR LOW VOLTAGE CONTROL, (1) FOR TEMPERATURE SENSOR & EEPR WIRING AND (1) FOR COMMUNICATION WIRING. PROVIDE PLASTIC BUSHING ON OPEN ENDS OF CONDUIT. VERIFY AND COORDINATE EXACT LOCATION OF WITH REFRIGERATION CONTRACTOR AND PROJECT MANAGER. 23. PROVIDE ELECTRICAL POWER WIRING TO COMPRESSOR RACK MAIN DISCONNECT. VERIFY AND COORDINATE WITH REFRIGERATION CONTRACTOR. SEE RISER DIAGRAM AND SCHEDULES FOR FEEDER AND DISCONNECT SIZES. LB-2 NL SCALE: 1/4" = 1'-0" FUTURE BATTERY BOX AC 04 16 2A/LA-16 4'-0" 15"W x 18"H SCALE: NONE 2A/LA-16 CR-7 E-3 PC CR-14 CR-16 J CR-19 20 J 9 5 2A/LA-15 2A LA-21 22 LD-1 PROVIDE ONE 1" CONDUIT TO EACH RTU 23 EWH 01 ECP (2) 1" CONDUITS FROM FIRE PULL STATION AND SECURITY KEYPAD IN FRONT OFFICE. 18 TO TBB 6"x6"x36" 3 7 7 2 1 CR-18 CR-13 CR-15 CR-15 CR-20 10 DUPLEX RECEPTACLES MOUNTED TO TELEBACKBOARD TYP. OF (4) SPACED AT 8"o.c. 6 PNL-CR SECURITY CR-5 15 3 2A/LA-16 FIRE 2A/LA-15 3/4" C. TO T.B. ...4"x4" WITH PLASTER RING FOR PHONE JACK CR-22 3 CR-17 3/4" AND 1" RIGID CONDUITS TO 1'-0" A.F.F. (PROVIDE BUSHINGS) 3/4" C. TO EMCC/ECP 21 CR-19 1612 MILLS SQUARE NL 19 ALP CR-28 J CR-13 42" MDP(E) 14 4'x4'x3/4" PLYWOOD FOR FIRE & SECURITY BACKBOARD 4'x8'x3/4" PLYWOOD FOR TELEPHONE BACKBOARD (TBB) 4'-0" MDP(E) 1'-6" E-4 ALEXANDER CITY, AL 15 1 CR-15 SS 01B STORE NUMBER CR-13 CR-13 LB-22,23,24,25 4 SS 01A CR-24 J PROJECT NUMBER 2A/LA-15 15 CR-7 2A/LA-16 PHONEBOARD PHONEBOARD 4 PNL-LA(E) 12 LIGHTING MEZZ. PLAN 03510-01 2"x6" WOOD BASE SHEET TITLE ENLARGED POWER PLAN & DETAILS 4 PNL-LB(E) PNL-LB(E) PNL-LD(E) PNL-LA(E) PNL-LD(E) PNL-LC(E) PNL-LC(E) SCALE: 1/4" = 1'-0" 11 SCALE: 1/4" = 1'-0" 8 POWER AND REFRIG.MEZZ. SHEET NUMBER E-4 SCALE: NONE 5 OFFICE ELEVATION SCALE: 1/4" = 1'-0" PROVIDE NEW CIRCUIT BREAKERS AS REQUIRED IN EXISTING PANELS. MATCH EXISTING MANUFACTURER. FIELD VERIFY REQUIRED NUMBER OF NEW BREAKERS. VERIFY REQUIRED AIC RATING WITH POWER COMPANY AND PROVIDE PROPERLY RATED BREAKERS. 4. VERIFY THAT EXISTING EQUIPMENT IS RATED FOR THE AVAILABLE FAULT CURRENT AND REPLACE AS REQUIRED. PROVIDE A SEPARATE PRICE FOR THIS WORK. 5. THAT PORTION OF THE WORK COMING UNDER THE JURISDICTION OF THE POWER COMPANY SHALL CONFORM TO ALL REQUIREMENTS OF THE POWER COMPANY AND ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID ANY AND ALL COST CHARGED BY THE POWER COMPANY TO EFFECT SUCH WORK. ELECTRICAL CONTRACTOR SHALL COOPERATE AND COORDINATE HIS WORK WITH THAT OF THE POWER COMPANY. 6. ALL BREAKERS IN PANEL TO BE AS SPECIFIED ON PANEL SCHEDULE. CONTRACTOR TO FURNISH NEW PANEL SCHEDULES FOR EACH AND ALL PANELS. 7. RE-USE EXISTING BREAKERS, FEEDERS, AND ELECTRICAL PANELS TO THE EXTENT POSSIBLE. PROVIDE NEW FEEDER AND BREAKER AS REQUIRED. C "COMPANY NAME" 20XX ALL RIGHTS RESERVED 3. PRELIMINARY NOT FOR BID OR CONSTRUCTION ALL PANELBOARDS AND BREAKERS SHALL BE MANUFACTURED BY SQUARE D, GE, EATON OR SIEMENS. DATE: 2. DESCRIPTION: REFEED ALL EXISTING CIRCUITS SERVING EQUIPMENT OR DEVICES THAT ARE TO REMAIN IN SERVICE. REV. NUMBER: 1. BY: GENERAL NOTES 1. EXISTING 120/208 VOLT, 3 PHASE, 2000 AMP ELECTRICAL SERVICE. VERIFY EQUIPMENT IS RATED FOR AVAILABLE FAULT CURRENT PER NEC, CORRECT DEFICIENCIES. 2. EXISTING WIRING FOR SERVICE, METER, AND FEEDERS TO ELECTRICAL PANELS TO REMAIN. LANDLORD TO VERIFY AND PROVIDE REQUIRED SERVICE GROUNDING PER N.E.C. 3. NOT USED. 4. PROVIDE LIGHTING CONTACTORS PER CONTACTOR SCHEDULE. 5. COORDINATE WITH REFRIGERATION CONTRACTOR AND VERIFY THAT CONTROL PANEL FOR COMPRESSOR RACK POWER IS RATED FOR THE AVAILABLE FAULT CURRENT. 6. SEE DETAIL 1 ON REFRIGERATION POWER PLAN FOR CONDENSER BRANCH CIRCUIT WIRING. 7. DISCONNECT EXISTING PANEL AND ABANDON IN PLACE. 8. DISCONNECT EXISTING PANEL - "PC" FED FROM PANEL "EM" AND RELOCATE TO INSIDE FRONT OFFICE. REUSE ALL EXISTING BREAKERS AS APPLICABLE. 9. RE-USE EXISTING PANEL "PC" IN THE OFFICE. RE-LABEL PANEL AS - "CR". PROVIDE ISOLATED GROUNDING AS INDICATED ON PANEL SCHEDULE. 10. SEE MAIN DISTRIBUTION SWITCHBOARD (MDS) SCHEDULE FOR FEEDER SIZES. CERTIFICATION: KEYED NOTES 11. RE-USE EXISTING PANEL "PLL" AND RE-LABEL PANEL AS "LA". 12. RE-USE EXISTING PANEL "PMA" AND RE-LABEL PANEL AS "LB". 13. RE-USE EXISTING PANEL "PH" AND RE-LABEL PANEL AS "LC". 14. RE-USE EXISTING PANEL "PM" AND RE-LABEL PANEL AS "LD". ELECTRICAL SYMBOL LEGEND NEW LIGHT SINGLE POLE SWITCH WITH PILOT LIGHT INDICATOR EXISTING LIGHT TO REMAIN MOTOR RATED SWITCH EXISTING LIGHT TO BE RELOCATED OR REMOVED WEATHERPROOF RECEPTACLE WALL PACK LIGHT ISOLATED GROUND DUPLEX RECEPTACLE DOCK LIGHT SPECIAL PURPOSE OUTLET (TYPE AS NOTED) EMERGENCY LIGHT WITH BATTERY PACK JUNCTION BOX EXIT LIGHT FLUSH MOUNTED FLOOR JUNCTION BOX, ROUTE ALL CONDUITS FROM J-BOX TO SPECIFIED PANELS VIA REFRIGERATION LINE TRENCH OCCUPANT SENSOR PC CONDUIT STUB-OUT PHOTO SENSOR/TEMPERATURE SENSOR 08/23/10 RECESSED CHANNEL DATE: QUADRUPLEX RECEPTACLE MKQ 2'X4' FLUORESCENT LIGHT CHECKED: WP GFI DUPLEX RECEPTACLE BER/BKR NL NON-SWITCHED NIGHT LIGHT DUPLEX RECEPTACLE DRAWN: MS SINGLE POLE SWITCH ELECTRIC DEFROST SERVICE AND DEFROST TERMINATION WIRING (1. PROVIDE CONDUIT AND WIRING TO COMPRESSOR RACK PER REFRIGERATION SCHEDULE FOR DEFROST POWER. 2. PROVIDE 2#18, RED COLOR CODED, CONDUCTORS AND WIRING FROM EACH REFRIGERATION SYSTEM TO COMPRESSOR RACK FOR DEFROST TERMINATION. PROVIDE CONDUIT IF REQUIRED BY CODE AND/OR TO ACCESS THROUGH FLOORS, WALLS AND CEILING). CONDUIT DROP FROM CEILING CONDUIT STUB-UP ELECTRICAL CONNECTION UNDER CASE DATA OUTLET ROOFTOP UNIT RTU-2 ROOFTOP UNIT RTU-3 ROOFTOP UNIT RTU-4 ROOFTOP UNIT CONDENSER-1 LIQUID SOLENOID AND EPR VALVE (PROVIDE 3/4" CONDUIT AND 2#14, 1#14 GND CONDUCTORS AND WIRING FROM EACH REFRIGERATION SYSTEM TO THE COMPRESSOR RACK). COMBINATION OF VOICE/DATA OUTLET NON-FUSED DISCONNECT SWITCH (TYPE AS NOTED) ROOF TOP 10 10 FUSIBLE DISCONNECT SWITCH (TYPE AS NOTED) 10 10 PP POWER POLE MOTOR PUSH BUTTON TO MDS TS TEMPERATURE SENSOR (PROVIDE 2#18 (SHIELDED BELDEN #8760 CABLE; (1) WHITE & (1) BLACK CONDUCTORS), AND WIRING FROM COMPRESSOR RACK TO EACH REFRIGERATION CASE, COOLER AND FREEZER BOXES. PROVIDE CONDUIT IF REQUIRED BY CODE AND AS REQUIRED TO ACCESS THROUGH FLOORS, WALLS AND CEILING). 1612 MILLS SQUARE ROOFTOP UNIT RTU-1 SIGNAL BELL T SENSOR.... TEMP/HUMIDITY (HANDY BOX MOUNTED) 6 PNL P/L PNL PLA PNL LA PNL RDP PNL LB PNL LD PNL LC PNL EM PNL PS 7 7 11 7 12 14 13 7 7 C 4 C 5 COMPRESSOR RACK ALEXANDER CITY, AL TELEPHONE OUTLET COMPRESSOR MEZZANINE 4 STORE NUMBER 10 PROJECT NUMBER TO ROOFTOP UNITS 03510-01 8 TO MDS 10 SHEET TITLE TO MDS PNL PD PNL A/C 7 BLDG. EXTERIOR 1 2 RISER DIAGRAM & PNL CR 9 BACKROOM FRONT OFFICE MAIN FLOOR SHEET NUMBER E-5 2 RISER DIAGRAM SCALE: N.T.S
© Copyright 2024