SYMBOL:
TAG:
SPEC SECTION:
GB
GB
26 05 26
ELECTRICAL DEMOLITION SYMBOL LIST
DESCRIPTION:
SYMBOL:
GROUND BUS
DESCRIPTION:
3
ELECTRICAL GENERAL NOTES
1.
2.
ECONN
E
26 05 33
ELECTRICAL CONNECTION
INDICATES EXISTING TO BE REMOVED
JB
J
F
26 05 33
JUNCTION BOX
"
FB-3
26 05 33
FLOOR BOX - FURNITURE FEED
LCS-1
26 09 33
LIGHTING CONTROL STATION
PANEL 'SBP-1'
PANEL 'LP-1P'
PANEL 'LP-1T'
PANEL 'EMLP-2'
26 24 16
PANELBOARD - SURFACE MOUNT
MX-#/MS-#/FCS-#
26 24 19
TRACK LIGHTING
WALL SCONCE LUMINAIRE
QUAD RECEPTACLE
W
PP
6.
MANUAL SWITCH / STARTER / COMBINATION
STARTER
E
ELECTRICAL CONNECTION, WALL MOUNTED
DISCONNECT / FUSED DISCONNECT
E
ELECTRICAL CONNECTION, CEILING OR FLOOR MOUNTED
SURFACE MOUNTED PANELBOARD
DUPLEX GFI RECEPTACLE, WEATHERPROOF
REC-QUAD
26 27 26
QUAD RECEPTACLE, 125V
PP
ARCH
PUSH PAD
NEP
F
7.
SYMBOL:
7.
DUPLEX RECEPTACLES FOR ELECTRIC WATER COOLERS (EWC) SHALL BE CONCEALED BEHIND
WATER COOLER ACCESS PLATE OR BE DIRECTLY BELOW AND CENTERED ON EWC.
CONTRACTOR SHALL VERIFY TYPE OF EWC TO BE INSTALLED.
8.
MOUNT ALL FIRE ALARM PULL STATIONS AT +42" FROM FLOOR (CENTERLINE DIMENSION)
EXCEPT WHERE OTHERWISE NOTED.
9.
INSTALL ALL WALL MOUNTED FIRE ALARM NOTIFICATION DEVICES AT 90" ABOVE FINISHED
FLOOR OR 6" BELOW THE CEILING, WHICHEVER IS LOWER, EXCEPT WHERE OTHERWISE NOTED.
HEIGHT SHALL BE MEASURED TO THE TOP OF THE DEVICE.
LUMINAIRE KEY:
DEVICE KEY:
FIRE ALARM AUDIO/VISUAL DEVICE
FIRE ALARM - MANUAL PULL STATION
6"X4' LUMINAIRE
A = MOUNTING (IF APPLICABLE)
1 = CIRCUIT NUMBER
8.
MOUNTING SUBSCRIPT KEY:
9.
SPEC SECTION:
SW-1P
26 27 26
SWITCH - SINGLE POLE
SW-1P-ADJ
26 27 26
SWITCH - LOCAL TIMER - USER ADJUSTABLE
SW-1P-K
26 27 26
SWITCH - SINGLE POLE - KEY LOCK
NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR (DARK LONG
DASHED LINE)
SW-D-FL
26 27 26
DIMMER - FLUORESCENT BALLAST
NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN (LIGHT SOLID LINE)
SW-D-LED
26 27 26
DIMMER - LED
EXISTING TO BE REMOVED BY THIS CONTRACTOR (DARK SHORT DASHED LINE)
SW-DCS
26 27 26
DIMMER CONTROL STATION
FIRE BARRIER DESIGNATIONS
SW-LS
26 27 26/
26 09 33
DAYLIGHT LEVEL SENSOR
SW-LS-D
26 27 26/
26 09 33
DAYLIGHT LEVEL SENSOR - 1 ZONE DIMMING
THE SYMBOLS SHOWN ARE FOR THE CONVIENIENCE OF THE CONTRACTOR. THE CONTRACTOR
SHALL VERIFY RATINGS WITH THE LATEST SET OF ARCHITECTURAL PLANS AND FURNISH ALL
MATERIALS REQUIRED TO COMPLY WITH THOSE RATINGS WHETHER SHOWN OR NOT.
SW-OC-D
26 27 26
OCCUPANCY SENSOR - DUAL TECHNOLOGY
ALL FLOOR, FLOOR CEILING, AND ROOF CEILING ASSEMBLIES SHALL BE DESIGNATED AS 1 HOUR
FIRE , BARRIER(S), UNLESS NOTED OTHERWISE ON THE PLANS.
0
SW-OC-P-0
26 27 26
SWITCH - OCCUPANCY SENSOR WALL SWITCH
02
SW-OC-P-02
26 27 26
SWITCH - OCCUPANCY SENSOR AND DUAL
SWITCH
K
F
D
PB#
LS
LS
D
OC
D
11. CONTRACTOR SHALL VERIFY ALL FURNITURE, MODULAR FURNITURE AND EQUIPMENT
LOCATIONS WITH ARCHITECTURAL PLANS, ELEVATIONS AND REVIEWED SHOP DRAWINGS.
PRIOR TO MAKING THE ACTUAL ELECTRICAL INSTALLATION THIS CONTRACTOR SHALL ADJUST
RECEPTACLES, OUTLETS OR CONNECTION LOCATIONS TO ACCOMMODATE FURNITURE AND/OR
EQUIPMENT.
RECEPTACLES AND TELECOMMUNICATIONS OUTLETS:
A
MOUNT ABOVE COUNTER (+6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH)
TAG:
T
10. CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL DETECTORS AND/OR SPEAKERS
WITH LUMINAIRES, SPRINKLER, AND CEILING DIFFUSERS. CENTER ALL DEVICES IN CEILING
TILE PATTERN. SMOKE DETECTORS SHALL BE LOCATED NO CLOSER THAN 3 FEET TO AN AIR
SUPPLY DIFFUSER OR RETURN GRILLE.
*IF LABEL IS ORIENTED HORIZONTALLY A / WILL SEPARATE THIS
INFORMATION. EX: A / 1
FIRE ALARM - EXTENDER PANEL
EMERGENCY LIGHTING UNIT
DESCRIPTION:
FLUSH MOUNT ALL DUPLEX RECEPTACLES AND TELECOMMUNICATION OUTLETS AT +18" FROM
FLOOR (CENTERLINE DIMENSION), EXCEPT WHERE OTHERWISE NOTED. RECEPTACLES AND
OUTLETS MAY BE SURFACE MOUNTED WHEN CONDUIT IS SPECIFIED EXPOSED.
DEVICE
SINGLE POLE SWITCH
ELECTRICAL SYMBOL LIST
6.
*IF LABEL IS ORIENTED HORIZONTALLY A / WILL
SEPARATE THIS INFORMATION. EX: F1 / 1 / A / NL
DISCONNECT SWITCH
AV
FLUSH MOUNT ALL TOGGLE SWITCHES AT +42" FROM FLOOR (CENTERLINE DIMENSION),
EXCEPT WHERE OTHERWISE NOTED. TOGGLE SWITCHES MAY BE SURFACE MOUNTED WHEN
CONDUIT IS SPECIFIED EXPOSED.
F1 = FIXTURE TAG
1 = CIRCUIT NUMBER
a = SWITCH NUMBER
LUMINAIRE NL = SUBSCRIPT (IF APPLICABLE)
FLOORBOX WITH TECHNOLOGY
26 27 26
5.
SHADED LUMINAIRE OR DEVICE INDICATES LUMINAIRE OR DEVICE IS CONNECTED TO AN
EMERGENCY CIRCUIT.
DUPLEX RECEPTACLE
REC-DUP-WP
CIRCUITS SERVING EMERGENCY AND EXIT LUMINAIRES WILL BE RUN IN SEPARATE RACEWAY
FROM ALL OTHER CIRCUITS.
INDICATES LUMINAIRE IS SWITCHED DURING NORMAL OPERATION AND OPERATES ON
EMERGENCY BRANCH UPON LOSS OF POWER THROUGH A LISTED TRANSFER DEVICE.
CONNECT THE SWITCHING DEVICE TO THE BALLAST FOR NORMAL OPERATION. EXTEND "AN"
UNSWITCHED PORTION OF THE SAME CIRCUIT TO THE FIXTURE, ALONG WITH A CONNECTION
TO THE EMERGENCY CIRCUIT. PROVIDE BODINE GTD OR EQUAL.
EXIT SIGN
DUPLEX GFI RECEPTACLE, 125V
4.
"SE"
FLOOR BOX - DUAL COMPARTMENT
26 27 26
A GREEN INSULATED GROUND CONDUCTOR, SIZED PER NEC SHALL BE INSTALLED WITH EACH
CIRCUIT.
5.
26 05 33
REC-DUP-GFI
3.
INDICATES LUMINAIRE IS UNSWITCHED FOR NIGHT LIGHT.
FB-2
DUPLEX RECEPTACLE, 125V
INDICATES KEYED NOTE USED TO DESCRIBE ADDITIONAL INFORMATION OF WORK REQUIRED,
SPECIFIC TO THE SHEET AND/OR DETAIL IT IS SHOWN WITH.
"
"NL"
4' INDUSTRIAL LUMINAIRE
26 27 26
CIRCUIT NUMBERS ARE SHOWN FOR CIRCUIT IDENTIFICATION. CIRCUITING SHALL AGREE WITH
NUMBERING ON THE PANEL PROVIDED. COMMON NEUTRALS MAY NOT BE USED FOR BRANCH
CIRCUITS. BALANCE THE LOAD ON PANEL AS EVENLY AS POSSIBLE BETWEEN EACH PHASE.
4.
FLOOR BOX - DUPLEX RECEPTACLE
REC-DUP
2.
DOWNLIGHT
26 05 33
26 28 16
THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADAAG (AMERICANS WITH
DISABILITIES ACT ACCESSIBILITY GUIDELINES).
#
FB-1
DS-# / FDS-#
1.
INDICATES ELECTRICAL EQUIPMENT DEFINED IN ELECTRICAL SCHEDULES OR SPECIFICATION.
REFER TO DRAWINGS CONTAINING ELECTRICAL SCHEDULES. PERMANENT NAMEPLATE SHALL
MATCH FINAL EQUIPMENT NOMENCLATURE, NOT ELECTRICAL EQUIPMENT TAG NAME, REFER TO
SPECIFICATIONS.
3.
2'X4' LUMINAIRE
J
E
MS-1
12. ELECTRICAL AND TELECOMMUNICATIONS EQUIPMENT SHALL BE MOUNTED TO AVOID
IMPEDANCE OF, OPERATION OF, AND/OR ACCESS TO ELECTRICAL AND MECHANICAL
EQUIPMENT. ALL MOUNTING OF ELECTRICAL AND TELECOMMUNICATIONS EQUIPMENT, ON
EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR, SHALL BE APPROVED IN ADVANCE BY THE
OTHER CONTRACTOR.
LINE TYPE KEY:
6"X1' LUMINAIRE
NEW WORK BY THIS CONTRACTOR (DARK SOLID LINE)
13. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL
OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE
EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR
SEALED INTO OPENINGS.
14. ALL WELDING SHALL BE ACCORDING TO AMERICAN WELDING SOCIETY STANDARDS.
CONTRACTOR SHALL FURNISH TO THE ARCHITECT/ENGINEER CERTIFICATES QUALIFYING EACH
WELDER, PRIOR TO START OF WORK. THE ARCHITECT/ENGINEER RESERVES THE RIGHT TO
REQUIRE QUALIFYING DEMONSTRATION, AT THE CONTRACTOR'S EXPENSE, OF ANY WELDERS
ASSIGNED TO THE JOB.
15. CONTRACTOR SHALL REMOVE AND REINSTALL ALL CEILING TILES AS REQUIRED FOR THE
EXECUTION OF ELECTRICAL WORK THAT IS OUTSIDE THE CONTRACT LIMITS OF
CONSTRUCTION. CONTRACTOR SHALL REPLACE CEILING TILES WITH IDENTICAL MATERIAL
WHERE DAMAGED BY THIS CONTRACTOR.
APPLICABLE CODES
1 HOUR FIRE BARRIER
1
ELECTRICAL INSTALLATION NOTES
"1/E-400" INDICATES DETAIL NUMBER/SHEET NUMBER.
INDICATES EXISTING TO REMAIN
E
2
CONTRACTOR SHALL COMPLY WITH APPLICABLE CODES AND
LOCAL AMENDMENTS.
ELECTRICAL CODE:
NEC 2011 EDITION
FIRE CODE:
IFC 2006 EDITION
LIFE SAFETY CODE:
NFPA 101 2009 EDITION
ENERGY CODE:
ASHRAE 90.1 2010
ONE LINE DIAGRAM NOTES
1.
AIC RATINGS LISTED FOR EQUIPMENT ARE MINIMUM REQUIREMENTS FOR BUS BRACING AND DEVICE
RATING. ALL EQUIPMENT SHALL BE FULLY RATED UNLESS SPECIFICALLY NOTED AS SERIES RATED.
2.
INDICATES DIRECT CONNECTION OF GROUND CONDUCTOR TO GROUND BUS.
3.
INDICATES O.Z. GEDNEY OR EQUAL GROUND BUSHING BONDED TO GROUND BUS WITH
CONDUCTOR SIZED TO MAXIMUM FEEDER GROUND CAPACITY.
ELECTRICAL SYMBOL LIST
D
SYMBOL:
TAG:
SPEC SECTION:
FAA
FAA-1
28 31 00
FIRE ALARM ANNUNCIATOR PANEL
SD
FA-120
28 31 00
FIRE ALARM SMOKE DETECTOR - CEILING
MOUNTED
SD
FA-122
28 31 00
FIRE ALARM DUCT SMOKE DETECTOR
F
FA-130
28 31 00
FIRE ALARM MANUAL PULL STATION
F
FA-153
28 31 00
FIRE ALARM AUXILIARY CONTROL RELAY
FA-200
28 31 00
FIRE ALARM VISUAL NOTIFICATION DEVICE WALL MOUNTED
FA-231
28 31 00
FIRE ALARM AUDIO/VISUAL NOTIFICATION
DEVICE - CEILING MOUNTED
V1
V3
V7 VH
DESCRIPTION:
ELECTRICAL SHEET INDEX
A1 A3
A7 AH
RI
A1
A3
A7 AH
NEP
KJWW # 12.0374.00 - Northbrook Public Library - Renovations || \\svkjwwrvt4\12\12.0374.00\MEPT13_12.0374.00_NORTHBROOK LIBRARY_CENTRAL.rvt
C
FA-241
28 31 00
FIRE ALARM REMOTE INDICATOR
FA-211
28 31 00
FIRE ALARM AUDIO/VISUAL NOTIFICATION
DEVICE - WALL MOUNTED
NEP-1
28 31 00
NAC EXTENDER PANEL
ELECTRICAL EQUIPMENT TAGS
ELECTRICAL COVER SHEET
GROUND LEVEL - ELECTRICAL DEMOLITION
SECOND LEVEL - ELECTRICAL DEMOLITION
ROOF LEVEL - ELECTRICAL DEMOLITION
ONE-LINE DIAGRAM - ELECTRICAL DEMOLITION
GROUND LEVEL - LIGHTING PLAN
GROUND LEVEL - POWER PLAN
ROOF LEVEL - POWER PLAN
GROUND LEVEL - SYSTEMS PLAN
ROOF LEVEL - SYSTEMS PLAN
ELECTRICAL DETAILS
ELECTRICAL SCHEDULES
ELECTRICAL SCHEDULES
ELECTRICAL ONE-LINE DIAGRAM
ELECTRICAL DEMOLITION NOTES
1.
THE ELECTRICAL DRAWINGS INDICATE EXISTING ELECTRICAL ITEMS TO BE REMOVED. THE DRAWINGS ARE
INTENDED TO INDICATE THE SCOPE OF WORK REQUIRED AND DO NOT INDICATE EVERY BOX, CONDUIT, OR
WIRE THAT MUST BE REMOVED. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTING A BID AND
VERIFY EXISTING CONDITIONS.
2.
ELECTRICAL ITEMS (i.e., LIGHTING FIXTURES, RECEPTACLES, SWITCHES, ETC.) REMOVED AND NOT
RELOCATED REMAIN THE PROPERTY OF THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE
DISPOSAL OF MATERIAL THE OWNER DOES NOT WANT TO REUSE OR RETAIN (i.e., FOR MAINTENANCE
PURPOSES).
THE CONTRACTOR SHALL OBTAIN APPROVAL FROM THE OWNER BEFORE TURNING OFF POWER TO CIRCUITS,
FEEDERS, PANELS, ETC. COORDINATE ALL OUTAGES WITH OWNER.
4.
WHERE LIGHTS, SWITCHES, RECEPTACLES, ETC., ARE BEING REMOVED ALL ASSOCIATED CONDUIT AND WIRE
BACK TO THE PANELBOARD OR FEEDER JUNCTION BOX SERVING THE DEVICE SHALL ALSO BE REMOVED,
UNLESS THE CONDUIT CAN BE REUSED FOR NEW CONDUCTORS.
5.
ALL CONDUIT SHALL BE REMOVED WHERE WALLS ARE BEING REMOVED. WHERE CONDUIT IS IN THE
CONCRETE SLAB, CUT OFF FLUSH, PULL OUT WIRE, AND PLUG. WHERE CONDUIT IS RUN EXPOSED, ALL
ASSOCIATED CLAMPS, SUPPORTS, HANGERS, ETC., SHALL ALSO BE REMOVED. CONDUIT CONCEALED IN WALL
CONSTRUCTION MAY BE ABANDONED IN PLACE IF NOT AFFECTED BY OTHER CONSTRUCTION.
RELATED
SPECIFICATION:
DESCRIPTION:
FB-#
FDS-#
FLOOR BOX
FUSIBLE DISCONNECT SWITCH, REFER TO DISCONNECT AND STARTER
SCHEDULE
26 05 33
26 28 16
6.
THIS CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER CONTRACTORS AT THE JOB SITE BEFORE
REMOVING EXISTING ELECTRICAL AND INSTALLING NEW ITEMS.
MS-#
MX-#
TC-#
MANUAL STARTER, REFER TO DISCONNECT AND STARTER SCHEDULE
MANUAL SWITCH, REFER TO DISCONNECT AND STARTER SCHEDULE
TIME SWITCH
26 14 19
26 14 19
26 09 33
7.
EXISTING CONDUIT IN GOOD CONDITION, MAY BE REUSED IN PLACE. RELOCATED EXISTING CONDUIT SHALL
NOT BE ALLOWED. BONDING CONDUCTORS SHALL BE INSTALLED IN ALL REUSED CONDUIT TO ASSURE
PROPER GROUND PATH.
LC-#
LIGHTING CONTACTOR, REFER TO LIGHTING CONTACTOR DETAIL 2/E-400
26 28 31
8.
EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY REQUIRE THE INSTALLATION OF A JUNCTION BOX TO
RECONNECT CIRCUITS THAT REMAIN IN OPERATION. EXTEND CONDUIT AND WIRING AS REQUIRED TO
MAINTAIN POWER TO REMAINING EQUIPMENT.
9
CONTRACTOR SHALL REMOVE AND INSTALL ALL CEILING TILES AS REQUIRED FOR THE EXECUTION OF
ELECTRICAL WORK THAT IS OUTSIDE THE CONTRACT LIMITS OF CONSTRUCTION. CONTRACTOR SHALL
REPLACE CEILING TILES WITH IDENTICAL MATERIAL WHERE DAMAGED BY THIS CONTRACTOR.
ABBREVIATION:
DESCRIPTION:
E.C.
F.P.C.
G.C.
H.C.
M.C.
P.C.
T.C.C.
T.C.
V.C.
ELECTRICAL CONTRACTOR
FIRE PROTECTION CONTRACTOR
GENERAL CONTRACTOR
HEATING CONTRACTOR
MECHANICAL CONTRACTOR
PLUMBING CONTRACTOR
TEMPERATURE CONTROLS CONTRACTOR
TELECOMMUNICATIONS CONTRACTOR
VENTILATION CONTRACTOR
AFF
ABOVE FINISHED FLOOR
CTs
CURRENT TRANSFORMERS
EWC
ELECTRIC WATER COOLER
N.C.
N.I.C.
N.O.
NC
SV
NORMALLY CLOSED
NOT IN CONTRACT
NORMALLY OPEN
NEW CONNECTION
SOLENOID VALVE
CKT
CIRCUIT
SEAL
3.
TAG:
ELECTRICAL ABBREVIATIONS
B
E-000
ED-101
ED-102
ED-103
ED-104
E-101
E-201
E-203
E-301
E-303
E-400
E-500
E-501
E-600
1201 CEDAR LANE
NORTHBROOK, IL 60062
ELECTRICAL SYMBOL LIST
4
AUDITORIUM AND FIRST FLOOR IMPROVEMENTS
5
NORTHBROOK PUBLIC LIBRARY
6
KEY PLAN
SCALE
10. BALLASTS MANUFACTURED PRIOR TO 1980 CONTAIN PCBs AND SHALL BE DISPOSED OF BY A FEDERAL OR
STATE E.P.A. APPROVED METHOD AND IN ACCORDANCE WITH SPECIFICATIONS.
NO SCALE
11. HID AND FLUORESCENT LAMPS CONTAIN MERCURY AND SHALL BE DISPOSED OF BY A FEDERAL OR STATE
E.P.A. APPROVED METHOD AND IN ACCORDANCE WITH SPECIFICATIONS.
2
1
ISSUED FOR BID
PERMIT RESPONSE #1
ISSUED FOR PERMIT
Desccription
No.
02/27/14
02/06/14
12/12/13
Date
REVISIONS
DRAWN BY
PT
APPROVED BY
CJE
CHECKED BY
JML
FEBRUARY 27, 2014
DATE
TITLE
ELECTRICAL
COVER SHEET
A
PROJECT NO.
1100 WARRENVILLE ROAD, SUITE 400W
NAPERVILLE, ILLINOIS 60563
630.527.2320 FAX: 630.527.2321
www.kjww.com
Experience you can build on. TM PROJECT # 12.0374.00
Illinois Design Firm Registration #184-000973
KJWW ENGINEERING RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS,
TO THIS DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR
DATA ARE THE EXCLUSIVE PROPERTY OF KJWW ENGINEERING AND SHALL NOT
BE USED OR REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN
APPROVAL AND PARTICIPATION OF KJWW ENGINEERING.
© 2014 KJWW, P.C.
ENGINEERING
CONSULTANTS
0
REFERENCE SCALE IN INCHES
1
2
3
E-000
SHEET NO.
50043997