ELECTRICAL DRAWING INDEX GENERAL NOTES 1. CONTROL/ELEMENTARY ELECTRICAL PLAN SYMBOLS SYMBOLS NORMALLY OPEN CONTACT S NORMALLY CLOSED CONTACT S3 LIMIT SWITCH, NORMALLY OPEN LIMIT SWITCH, NORMALLY CLOSED SV PRESSURE SWITCH, NORMALLY OPEN PRESSURE SWITCH, NORMALLY CLOSED SM FLOAT SWITCH, NORMALLY OPEN FLOAT SWITCH, NORMALLY CLOSED SP FLOW SWITCH, NORMALLY OPEN FLOW SWITCH, NORMALLY CLOSED S WP TEMPERATURE SWITCH, NORMALLY OPEN TEMPERATURE SWITCH, NORMALLY CLOSED NORMALLY OPEN, TIMED TO CLOSE CONTACT NORMALLY OPEN, TIMED TO OPEN CONTACT AR ALARM RELAY AT ALARM TIMER CR CONTROL RELAY F/T FIT FSH FSL FLOW SWITCH HIGH/LOW LS LIMIT SWITCH OR LEVEL SWITCH M MOTOR STARTER PRESSURE GAUGE PFT PROCESS FLOW TIMER POWER FACTOR METER KILOWATT METER AMMETER THREE PHASE VOLT SWITCH WALL OUTLET BOX AND 20 AMP SWITCH WITH PILOT LIGHT. AS THREE PHASE AMP SWITCH WALL OUTLET BOX AND 20 AMP SWITCH WITH WEATHERPROOF COVER OR ENCLOSURE. AT CURRENT TRANSMITTER WALL OUTLET BOX AND 20 AMP DUPLEX RECEPTACLE 18" TO KW KILOWATT TRANSMITTER WALL OUTLET BOX AND 20 AMP DUPLEX RECEPT MOUNTED 48"AFF OR ABOVE PFT POWER FACTOR TRANSMITTER WALL OUTLET BOX AND 20 AMP GFCI DUPLEX RECEPTACLE AT 18" TO CP LOCAL CONTROL PANEL WALL OUTLET BOX AND 20 AMP GFCI RECEPTACLE MOUNTED 48"AFF OR ABOVE COUNTER, OR AS NOTED. GFI GROUND FAULT INTERRUPTER W PHASE CONDUCTOR OR SWITCH LEG, LONG INDICATE NEUTRAL CONDUCTOR. GREEN GROUND CONDUCTOR NOT SHOWN; ALL CONDUITS REQUIRE COPPER GROUND CONDUCTOR. TWO CONDUCTORS PLUS GROUND REQUIRED, MINIMUM. CONDUCTORS SHALL NOT BE SPLICED WITHOUT WRITTEN PERMISSION FROM THE ENGINEER. BRANCH CIRCUIT PANELBOARD PRESSURE SWITCH TS TAMPER SWITCH TR TIMING RELAY S/S SURGE SUPPRESSION DEVICE SV SOLENOID VALVE SCHEDULES ALL DISCONNECTS, J-BOXES, TERMINAL CABINETS, ETC. & MOUNTING 5. ALL CONDUITS (POWER, CONTROL, INSTRUMENTATION, ETC.) SHALL HAVE 45 WATT HOUR METER ELECTRIC A.C. MOTOR, NO. INDICATES HORSEPOWER. NO ELECTRIC D.C. MOTOR, NO. INDICATES HORSEPOWER. FOR ALL MOTOR LOADS SERVED THROUGH NON-FUSIBLE DISCONNECT SWITCH, 30A,3P UNLESS 9. PROVIDE A #2 BOND FROM ALL FIELD INSTRUMENTS, MOTORS, CONTROL 10. PROVIDE 2' MINIMUM DISTANCE BETWEEN PARALLEL RUNS OF LOW VOLTAGE AS REQUIRED BY ELEMENTARY DIAGRAMS OR SPECS. VARIABLE FREQUENCY DRIVES; 12. 13. 14. TORQUE SWITCH HP ZERO SPEED SWITCH 15. ALARM INDICATING LIGHT RUN INDICATING LIGHT LIGHTING PANELBOARD HP AIR HANDLING UNIT CONNECTION; PROVIDE FUSED DISCONNECT AS REQUIRED BY EQUIPMENT NAMEPLATE; MAKE CONNECTIONS. ELECTRIC DUCT HEATER CONNECTION; PROVIDE FUSED DISCONNECT AS REQUIRED BY EQUIPMENT NAMEPLATE; MAKE CONNECTIONS. MOMENTARY CONTACT PUSHBUTTON MOMENTARY BREAK PUSHBUTTON OR RESET KEYED SWITCH MANUAL TRANSFER SWITCH OR REVERSING SWITCH K K:\CCUD IQ Telemetry\Priority 2\E1.dwg Plotted: Nov 14, 2011 - 9:54am by tracy ADDITIONAL CONDUIT FOR CONDUCTORS AS SHOWN ON RISER, ONE-LINE DIAGRAMS, DETAILS AND NOTES. ALL CIRCUITS SHALL BE IDENTIFIED IN JUNCTION BOXES, PULL BOXES, CONTROL PANELS, PANELBOARDS, LIGHTING POLES, CONTROLLERS AND SERVICE POINTS. IDENTIFICATION SHALL MATCH PANELBOARD SCHEDULES, MCC SECTION, I&C SHOP DRAWINGS & SCHEDULES & TAG LISTS, ETC. CURRENT TRANSFORMERS POTENTIAL TRANSFORMERS ALL EXCAVATIONS FOR CONDUITS, HANDHOLES, MANHOLES AND PULLBOXES NEAR EXISTING PIPING, CONDUIT AND EQUIPMENT SHALL BE HAND 18. GROUNDING CONNECTIONS BELOW GRADE SHALL BE EXOTHERMIC UNLESS SPECIFICALLY INDICATED OTHERWISE. 19. ALL ENCLOSURES, TERMINAL CABINETS, WIREWAYS, PULL BOXES ETC. SHALL 20. CONTRACTOR SHALL CORE DRILL EXISTING CONCRETE WALLS, FLOORS, MANHOLES, HANDHOLES AND PULL BOXES FOR CONDUIT PENETRATIONS. LIGHTNING PROTECTION AIR TERMINAL; 21. STREAMER RETARDING AIR TERMINAL MOUNTED TO LIGHT POLE TOP. MAIN ROOF CONDUCTOR TYPICAL ALL CONDUITS PENETRATING RATED FIRE WALLS OR RATED FIRE FLOORS SHALL BE INSTALLED WITH U.L. APPROVED DEVICES TO MAINTAIN THE FIRE RATING OF THE WALL OR FLOOR PENETRATED. 22. PROVIDE CONDUIT DUCT SEAL AT ALL CONDUIT ENDS. #2 TINNED BARE COPPER 23. FLEXIBLE CONDUITS SHALL BE USED TO TERMINATE ALL MOTORS AND OTHER #2 TINNED BARE COPPER 24. PROVIDE TYPEWRITTEN PANEL SCHEDULES IN PANELBOARD & TYPEWRITTEN STREAMER RETARDING TYPE. HOA HAND OFF AUTO CONTROL STATION G COUNTERPOISE LOOP GROUND COUNTERPOISE LOOP GROUND TWISTED SHIELDED PAIRS 25. RKS Electrical, Instrumentation & Control Design HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 TRACY PROKOPETZ PE #62427 P.E. Certificate of Authorization #8212 NO. DATE REVISIONS BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS CONTROL PANEL DETAILS VETERANS PARK CONTROL PANEL DETAILS ELECTRICAL DETAILS RTU ANTENNA & ELECTRICAL DETAILS EQUIPMENT RACK LOCATIONS SHOWN ON PLANS ARE APPROXIMATE PREFERRED LOCATIONS ONLY. COORDINATE LOCATION OF EQUIPMENT RACK WITH LOCATION OF REUSE PIPING. DO NOT MOUNT RACK DIRECTLY ABOVE PIPING. MOUNT RACK TO ALLOW MAINTENANCE. 3. CONTRACTOR IS REQUIRED TO HAVE SITES PROPERTY LINES SURVEYED AND STAKED PRIOR TO PLACEMENT OF EQUIPMENT RACK. COORDINATE EQUIPMENT RACK LOCATION WITH PROPERTY LINES AS REQUIRED. 4. WORK IN THE RIGHT OF WAY REQUIRES RIGHT OF WAY PERMIT. COORDINATE EQUIPMENT RACK LOCATION WITH PIPING AND RIGHT OF WAY LIMITS. 5. COORDINATE FINAL LOCATION OF RACK WITH COUNTY, DOCUMENT COORDINATION TO ENGINEER. VIBRATING EQUIPMENT AND SHALL BE BETWEEN 18" AND 2' IN LENGTH. TERMINAL BLOCK SCHEDULES IN TERMINAL CABINETS; PROPOSED & MODIFIED. SERVICE OR EQUIPMENT GROUND. Consulting Engineers TARPON COVE, CALUSA BAY & VINEYARDS ELEMENTARY SEAL PENETRTATIONS WITH NON-SHRINK GROUT OR APPROPRIATE FIRE RATED DEVICES WHERE APPLICABLE. CONTROL POWER TRANSFORMER HAND OFF REMOTE CONTROL STATION PLAN CONTAIN A GROUNDING BUS BAR. CONNECT ALL RACEWAY BONDS TO BUS BAR VIA GROUNDING BUSHING AND EXTEND BONDING JUMPER FROM BUS BAR TO ENCLOSURE. SYSTEMS CABINET AS NOTED OR MARKED. HOR VINEYARDS ELEMENTARY POWER, INSTRUMENTATION & CONTROLS, LIGHTNING PROTECTION BONDING & GROUNDING FINISHED GRADE DIRECTLY ABOVE ALL UNDERGROUND YARD CONDUITS. MOLDED CASE CIRCUIT BREAKER LP LIGHTNING PROTECTION BONDING & GROUNDING PLAN GRADE SHALL BE 30" UNLESS OTHERWISE NOTED. SYSTEMS BACKBOARD AS NOTED COPPERWELD GRD. ROD CALUSA BAY POWER, INSTRUMENTATION & CONTROLS, FOR EXCAVATION OF PIPING AS REQUIRED FOR PERPENDICULAR TO WALLS, STRUCTURAL MEMBERS OR INTERSECTIONS OF VERTICAL PLANES AND CEILINGS, WITH RIGHT ANGLE TURNS CONSISTING OF PROVIDE COLORED WARNING TAPE 6" WIDE SHALL BE INSTALLED 12" BELOW MANUAL OR AUTOMATIC TRANSFER SWITCH 2. EXPOSED RUNS OF CONDUITS SHALL BE INSTALLED WITH RUNS PARALLEL OR FUSE REMOTE TERMINAL BLOCK POINT TSP PLAN DRAWINGS DO NOT SHOW ALL CONDUITS REQUIRED. PROVIDE 17. KIRK KEY INTERLOCK SYSTEM SYMBOL LEGEND MAINTAINED CONTACT LIGHTNING PROTECTION BONDING & GROUNDING PLAN EQUIPMENT RACK LOCATION NOTES: 1. MINIMUM DEPTH FROM TOP OF DUCTBANKS OR CONDUITS TO FINISHED MAINTAINED CONTACT ON-OFF SWITCH START/STOP (S/S) CONTROL SWITCH RECOMMENDATION. CONTRACTOR SHALL INSTALL PULL BOXES TO MEET 16. POWER PANELBOARD MOTOR OPERATED VALVE CONNECTION CONDUCTOR PULLING TENSIONS SHALL NOT EXCEED MANUFACTURER'S EXCAVATED AND COORDINATED WITH ENGINEER. COMBINATION MAGNETIC MOTOR STARTER PROVIDED BY ELECTRICAL U.N.O. MOTOR CONNECTION MOV E7 E8 E9 VETERANS PARK POWER, INSTRUMENTATION & CONTROLS, 480V/120V POWER CONDUITS AND I&C CONDUITS. POWER CONDUIT SHALL SYMMETRICAL BENDS OR PULL BOXES AS INDICATED ON THE DRAWINGS. BENDS AND OFFSETS SHALL BE AVOIDED WHERE POSSIBLE. PROVIDE SURGE SUPPRESSION DEVICE EQUAL TO SQ.-D. SP3650 OR EQUAL VIBRATION SWITCH E6 LIGHTNING PROTECTION BONDING & GROUNDING PLAN PANELS, TERMINATION CABINETS, ETC TO THE GROUND GRID. MANUFACTURER'S REQUIREMENTS. NON-FUSIBLE DISCONNECT SWITCH, 30A,3P UNLESS OTHERWISE INDICATED, WITH REMOTE CONTROL STATION AT DISCONNECT. REMOVE CONDUCTORS BACK TO PANEL/MCC. REMOVE CONDUIT BACK TO FIRST MANHOLE, HANDHOLE OR DRAWINGS DO NOT SHOW EXACT ROUTING OF CONDUIT. COORDINATE CONDUIT LOCATIONS WITH OTHER TRADES SO THAT CONFLICTS ARE AVOIDED. SERVICE OR EQUIPMENT GROUND. SERVING MOTOR LOADS OF 10HP OR GREATER AND DO NOT ABANDON ELECTRICAL IN PLACE. 8. OTHERWISE INDICATED. FOR DISCONNECTS EQUIPMENT GROUNDING CONDUCTOR SIZED PER TABLE 250.122 OF THE N.E.C. ALL CONTROL PANELS SHALL BE CONSTRUCTED BY A UL508A APPROVED PANEL VENDOR AND SHALL BEAR A UL508A LABEL ON THE PANEL. THE PANEL SHALL ALSO BE RATED AND LABELED FOR A 10KAIC MINIMUM SCC. 11. NO DISCONNECT SWITCH SIZE PER EQUIPMENT NAME PLATE OR AS NOTED: E5 GENERAL NOTES CROSS INSTRUMENTATION CONDUIT PERPENDICULARLY AT RIGHT ANGLES WITH 6" SEPARATION FOR 480V/120V. TYPICAL STARTER CONTROL. SEE SWITCHGEAR CONTROL DIAGRAMS FOR EXACT TYPE. TRANSFORMER, SIZE AS INDICATED E4 HARDWARE SHALL BE NEMA 4X STAINLESS STEEL UNLESS NOTED OTHERWISE. 7. MOLDED CASE CIRCUIT BREAKER AS NOTED; SEE PANEL TARPON COVE POWER, INSTRUMENTATION & CONTROLS, E3 4. CONDUIT AND WIRE CONCEALED IN FLOOR SLAB OR UNDERGROUND. PS ELECTRICAL SYMBOLS LEGEND, DRAWING INDEX & E2 REUSE FOR NEW WORK. REMOVE COMPLETE DUCT BANK AND MANHOLES IF NOT BEING REUSED. SLASH MARKS INDICATE NUMBER OF CONDUCTORS; (MARKS SHOWN TO AID CONTRACTOR IN BIDDING, THE 3. CAPACITOR BRANCH CIRCUIT CONDUIT AND WIRE GENERALLY SURFACE MOUNTED, CONCEALED ABOVE CEILINGS PROVIDE SCHEDULE 80 PVC CONDUIT BELOW GRADE. FUSE FLUSH MOUNTED JUNCTION BOX ( SURFACE IN MECH/ELEC SPACES OR ABOVE CEILINGS). ALL WORK SHALL COMPLY WITH THE NATIONAL ELECTRICAL CODE, NATIONAL ELECTRICAL SAFETY CODE, UTILITY REQUIRMENTS AND LOCAL CODES. 2. 6. DRAW-OUT CIRCUIT BREAKER CONTRACT SUM WHETHER OR NOT SHOWN). SHORT SLASHES INDICATE P/G VOLTMETER VS CONTRACTOR SHALL PROVIDE THE REQUIRED CONDUCTORS UNDER THE MOTOR SWITCH MANUAL K MANUAL MOTOR STARTING SWITCH WITH OVERLOADS AND PILOT LIGHT. NEMA 4X TYPICAL PHOTOCELL ON ROOF J LEVEL INDICATOR TRANSMITTER MS R KW A CENTERLINE. WP INDICATES WEATHERPROOF COVER PLATE. FLOW INDICATOR TRANSMITTER (TOTALIZER) LIT A CONNECTIONS. PF WALL OUTLET BOX AND SPECIAL PURPOSE RECEPTACLE AS NOTED OR COORDINATE. L/T ZS WALL OUTLET BOX AND EXHAUST FAN SPEED CONTROLLER/SWITCH V CENTERLINE FS LIQUID LEVEL SWITCH VS 48" TO CTR LINE. WALL OUTLET BOX AND DOUBLE 20 AMP DUPLEX RECEPTACLES 18" TO LLS YSH WALL OUTLET BOX AND 20 AMP 3-WAY SWITCH (`a' INDICATES SWITCHES) COUNTER OR AS NOTED. NORMALLY CLOSED, TIMED TO CLOSE CONTACT ANALYZER INDICATOR TRANSMITTER 48" TO CENTERLINE. CENTERLINE NORMALLY CLOSED, TIMED TO OPEN CONTACT AIT WALL OUTLET BOX AND 20 AMP SINGLE POLE SWITCH (`a' INDICATES SWITCHES) SINGLE LINE DIAGRAM SYMBOLS E1 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: E1.dwg BRANCH CIRCUITS EXCEEDING 75 FT IN LENGTH SHALL BE WIRED WITH MINIMUM #10 AWG WIRES. COUNTY WATER-SEWER DISTRICT COLLIER COUNTY, FLORIDA ELECTRICAL SYMBOLS LEGEND, DRAWING INDEX & GENERAL NOTES PROJECT NO. : 2011.027 DATE : 11/11 SHEET NO. : E1 OHW 2' 0 1/4"=1'-0" OHP X X X X X X X X X X * 1' OHP 2' X X SV SV MOV VALVE CONTROL PANEL (VCP). 5. FIBER INTERFACE BOX PROVIDED BY COLLIER COUNTY I.T. MAKE CONNECTIONS. COORDINATE WITH COUNTY PM & IT. X X X X X X X X X X X X X G G G X X X X G M 15 11 X 11. #2 TINNED SOLID COPPER TO EQUIPMENT/ 12. #2/0 STRANDED TINNED BARE COPPER 13. #2/0 STRANDED TINEND BARE COPPER BOND 14. (3) #14 IN 0.75"C. 15. FLAT ROOF MOUNTED AIR TERMINAL WITH DOWN CONDUCTOR TO COUNTERPOISE. 16. FLOW CONTROL VALVE COORDINATE EXACT TEST WELL (SEE DETAIL). TYPICAL. CABINETS ETC. TYPICAL. COUNTERPOISE LOOP GROUND. TYPICAL. TO FENCE. 1 INTERCONNECTING WIRE REQUIREMENTS WITH BOX AND PLC, AND PLC AND VALVE DEVICES. 17. X G M TARPON COVE SITE PLAN APPROXIMATE SCALE: 1"=10'-0" INTERCONNECTING WIRING BETWEEN JUNCTION G 12 2 PAIR #16 TSP INSTRUMENT CABLE IN 1"C. NEMA 4X SS 240V/120 MOV 70A, 240V,2P, FPL APPROVED DIRECT READING UTILITY METER & METER CAN 1∅ SERVICE G PIT PROPOSED X G 20' DRIVEN GROUND ROD WITH INSPECTION PROVIDE JUNCTION BOX AND ALL REQUIRED X G 12 FIT 10. 2 VALVE MANUFACTURES SUBMITTALS PRIOR TO ROUGH-IN. ELECTRICAL CONTRACTOR TO G JB SV SV 15 CONDUCTOR #14 CONTROL CABLE IN 1.25"C. X G X 15 9. OHP X X CAT 6 ETHERNET CABLE IN 1"C. OHP G G X 8. IN 0.75"C. OHP X CAT 6 ETHERNET CABLE IN 1"C AND (3) #12 OHP X 7. 1" CONDUIT. OHP 13 5 CONDUCTOR, #14 CONTROL CABLE IN X TARPON COVE ELECTRICAL PLAN X 6 M OHP X 10 SE RATED ENCLOSED BREAKER VALVE CONTROL PANEL G X 4. ENTRANCE RATED ENCLOSED BREAKER. OHP 16 11 10 G G G X X X X G G X G X 12 G X G X 13 G X X X K:\CCUD IQ Telemetry\Priority 2\E2.dwg Plotted: Nov 13, 2011 - 2:01pm by tracy 60A, 240/120V, SINGLE PHASE SERVICE PIT X X M FIT 3. X X 7 14 PROPOSED UNDERGROUND SERVICE LATERAL. CONTRACTOR TO FIELD VERIFY EXACT LENGTH. OHP JB 2. * 17 9 14 AERIAL TRANSFORMER WITH POLE BASE HANDHOLE. CONTRACTOR TO COORDINATE AND SCHEDULE SERVICE CONNECTION WITH FPL. OHP 4 6 KEYNOTES PROPOSED FPL 240V/120V, 1ø OHW 1. M # 5 * 3 X X M OHP X 8 X PROPOSED FPL POLE BASE HANDHOLE X (3)#6 IN SS 1"C. #2 TARPON COVE GROUNDING & BONDING PLAN (3) #6 & #6G (3) #6 IN 1"C. IN 1"C. ELECTRICAL RISER DRAWING N.T.S. RKS Consulting Engineers Electrical, Instrumentation & Control Design HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 TRACY PROKOPETZ PE #62427 P.E. Certificate of Authorization #8212 NO. DATE REVISIONS BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: E2.dwg COUNTY WATER-SEWER DISTRICT COLLIER COUNTY, FLORIDA TARPON COVE POWER, INSTRUMENATION & CONTROLS, LIGHTNING PROTECTION BONDING & GROUNDING PLAN PROJECT NO. : 2011.027 DATE : 11/11 SHEET NO. : E2 X 4' 2' 0 X X X X X 4' 1/8"=1'-0" X X X X X PIT M 15 MOV 9 3 5 8 7 FIT X 14 SV 16 SV JB 14 X X X X X 6 # 1. 4 X VETERANS PARK SITE ELECTRICAL PLAN X X X TO FENCE X X X 13 IN EXISTING PANELBOARD FOR SERVICE TO REUSE CONNECTION. FIELD COORDINATE LOCATION OF PANELBOARD AND MATCH EXISTING MANUFACTURER AND BREAKER TYPE. (3) #3 IN 1"C. 3. EXISTING PARK BOOSTER PUMP AND CONTROL PANEL TO REMAIN. 4. VALVE CONTROL PANEL (VCP). 5. RTU ANTENNA TOWER. 6. 5 CONDUCTOR, #14 CONTROL CABLE IN 7. CAT 6 ETHERNET CABLE IN 1"C AND (3) #12 8. COAX RADIO CABLE IN 1"C. 9. 15 CONDUCTOR #14 CONTROL CABLE IN 1.25"C. 10. 20' DRIVEN GROUND ROD WITH INSPECTION 11. #2 TINNED SOLID COPPER TO EQUIPMENT/ 12. #2/0 STRANDED TINNED BARE COPPER 13. #2/0 STRANDED TINNED BARE COPPER BOND 14. (3) #14 IN 0.75"C. 15. 2 PAIR #16 TSP INSTRUMENT CABLE IN 1"C. 16. FLOW CONTROL VALVE COORDINATE EXACT G G G G 1" CONDUIT. IN 0.75"C. TEST WELL (SEE DETAIL). TYPICAL. CABINETS ETC. TYPICAL. COUNTERPOISE LOOP GROUND. TYPICAL. 1 G G G 2 SEE DETAIL. G G G G G G G G G G G G G G G G G G G G G G MOV PROVIDE 120V, 30A, SINGLE POLE BREAKER 2. G PIT M KEYNOTES G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G G TO FENCE. G G G G G G G G G G G G G G G G G G G G G G G G G G 11 12 G G G G G G G FIT G G G G G G G G G G G G G G G G SV G G G G G G G G G G G G G G SV G G G G G G G SV G G G G G G G G G G G G G G G G G G G G VALVE MANUFACTURES SUBMITTALS PRIOR TO ROUGH-IN. ELECTRICAL CONTRACTOR TO G G G G G PROVIDE JUNCTION BOX AND ALL REQUIRED G G G G G K:\CCUD IQ Telemetry\Priority 2\E3.dwg Plotted: Nov 14, 2011 - 11:54am by tracy INTERCONNECTING WIRING BETWEEN JUNCTION G 10 G G G G G G G G G G G G INTERCONNECTING WIRE REQUIREMENTSW WITH G BOX AND PLC, AND PLC AND VALVE DEVICES. VETERANS PARK SITE PLAN APPROXIMATE SCALE: 1"=20'-0" X X X X X X VETERANS PARK SITE GROUNDING & BONDING PLAN RKS Consulting Engineers Electrical, Instrumentation & Control Design HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 TRACY PROKOPETZ PE #62427 P.E. Certificate of Authorization #8212 NO. DATE REVISIONS BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: E3.dwg COUNTY WATER-SEWER DISTRICT COLLIER COUNTY, FLORIDA VETERANS PARK POWER, INSTRUMENATION & CONTROLS, LIGHTNING PROTECTION BONDING & GROUNDING PLAN PROJECT NO. : 2011.027 DATE : 11/11 SHEET NO. : E3 NOTICE OF SPECIAL REQUIREMENTS: 6 JB 14 TYPICAL INSTALLATION METHODS AS REQUIRED TO M 9 7 14 PIT M 4 MEET THE 14' HEIGHT RESTRICTION. # MOV 1. 16 KEYNOTES G G G G 10 M PIT M 3. 60A, 240/120V, SINGLE PHASE SERVICE 4. VALVE CONTROL PANEL (VCP). 5. FIBER INTERFACE BOX PROVIDED BY COLLIER COUNTY I.T. MAKE CONNECTIONS. COORDINATE WITH COUNTY PM & IT. FIT MOV 6. 5 CONDUCTOR, #14 CONTROL CABLE IN 7. CAT 6 ETHERNET CABLE IN 1"C AND (3) #12 8. CAT 6 ETHERNET CABLE IN 1"C. 9. 15 CONDUCTOR #14 CONTROL CABLE IN 1.25"C 10. 20' DRIVEN GROUND ROD WITH INSPECTION 11. #2 TINNED SOLID COPPER TO EQUIPMENT/ 12. #2/0 STRANDED TINNED BARE COPPER 13. 24x24x18 FLUSH ON GRADE HEAVY DUTY 11 11 G G 10 PROPOSED UNDERGROUND SERVICE LATERAL. CONTRACTOR TO FIELD VERIFY EXACT LENGTH. DIRECTIONAL DRILL ENTIRE SERVICE LATERAL. G G JB SV SV 12 G G G 12 LEAVE 7' EXCESS LOOP 2. 15 15 G MOUNT TRANSFORMER. OF CONDUCTORS AT TRANSFORMER LOCATION FOR SERVICE CONNECTION. CONTRACTOR TO COORDINATE AND SCHEDULE SERVICE CONNECTION WITH FPL. CALUSA BAY ELECTRICAL PLAN G APPROXIMATE LOCATION OF EXISTING FPL PAD 12 G CALUSA BAY GROUNDING & BONDING PLAN X FIT SV SV 17 3 5 M M RESTRICTIONS REQUIRE ALL STRUCTURES, CONSTRUCTION EQUIPMENT, MACHINERY ETC TO BE UNDER 14' IN HEIGHT. CONTRACTOR TO MODIFY 8 ANK ROA D 1/8"=1'-0" TTE - FR THEREFORE ASSOCIATED CONSTRUCTION LIES WITHIN AN FPL TRANSMISSION COORIDOR. FPL 4' 0 GOODLE 2' ENTRANCE RATED ENCLOSED BREAKER. EAST RIGHT -OF-WAY LIN E 4' LOCATION OF IQ SERVICE CONNECTION AND X 100' FLOR IDA POWER & LIGHT CO MPANY EASEMENT 1" CONDUIT. IN 0.75"C. TEST WELL (SEE DETAIL). TYPICAL. 2 CABINETS ETC. TYPICAL. COUNTERPOISE LOOP GROUND. TYPICAL. QUAZITE OPEN BOTTOM PULL BOX WITH BOLT ON TRAFFIC RATED COVER. 14. (3) #14 IN 0.75"C. 15. FLAT ROOF MOUNTED AIT TERMINAL WITH DOWN CONDUCTOR. 16. FLOW CONTROL VALVE COORDINATE EXACT INTERCONNECTING WIRE REQUIREMENTS WITH VALVE MANUFACTURES SUBMITTALS PRIOR TO ROUGH-IN. ELECTRICAL CONTRACTOR TO PROVIDE JUNCTION BOX AND ALL REQUIRED INTERCONNECTING WIRING BETWEEN JUNCTION K:\CCUD IQ Telemetry\Priority 2\E4.dwg Plotted: Nov 13, 2011 - 2:03pm by tracy BOX AND PLC, AND PLC AND VALVE DEVICES. NEMA 4X SS FPL APPROVED DIRECT READING UTILITY METER & METER CAN EXISTING FPL PAD MOUNT 240V/120V SINGLE PHASE TRANSFORMER 17. 70A, 240V,2P, SE RATED ENCLOSED BREAKER 2 PAIR #16 TSP INSTRUMENT CABLE IN 1"C. 2 SS (3)#1 IN 1.5"C. COIL 7' OF 1 #2 (3) #6 & #6G EXCESS CONDUCTORS FOR FPL CONNECTION. (3) #1 IN 1.5"C. IN 1"C. ELECTRICAL RISER DRAWING N.T.S. CALUSA BAY SITE PLAN APPROXIMATE SCALE: 1"=40'-0" RKS Consulting Engineers Electrical, Instrumentation & Control Design HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 TRACY PROKOPETZ PE #62427 13 VALVE CONTROL PANEL P.E. Certificate of Authorization #8212 NO. DATE REVISIONS BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: E4.dwg COUNTY WATER-SEWER DISTRICT COLLIER COUNTY, FLORIDA CALUSA BAY POWER, INSTRUMENATION & CONTROLS, LIGHTNING PROTECTION BONDING & GROUNDING PLAN PROJECT NO. : 2011.027 DATE : 11/11 SHEET NO. : E4 N 240 VOLTS PLUS NEUTRAL FROM UTILITY N 120V N NEMA 3R STAINLESS STEEL HINGED 3 POINT LATCH CABINET PAINTED WHITE CONTINUOUS STAINLESS STEEL HINGE PROVIDE WITH SUNSHIELD WITH WHITE POWDER COAT FINISH AR1 20A-1P L1 2A-1P TO MOV 5A-1P L2 TO FLOWMETER G 24VDC POWER SUPPLY FUSE 4-20mA LOOP for HART PROT. SPD R6 DOOR INTRUSION SWITCH 20A-1P VALVE CONTROL PANEL LOUVER EDCO HSP-121 20A-1P INTERNAL LIGHT KIT WITH TERMINAL BLOCKS AND INTEGRAL CONVENIENCE RECEPTACLE CONTROLLED AUTOMATICALLY VIA DOOR SWITCH 36" X 48" X 12" MIN SIZE. PANEL INT LT & RECEPT. R1 R2 MOV OPEN MOV CLOSE MOV FAULT OR NOT IN AUTO BACKPRESSURE VALVE OPEN COMMAND A B CLOSE COMMAND BACKPRESSURE SUSTAINING VALVE NOT IN AUTO W A CLOSE OPEN UTIL. POWER AUTO G UTILITY POWER A G MOV FAULT OR NOT IN AUTO MOV R7 MOV CLOSED MOV NOTE: ELEVATION SHOWN WITH EXTERIOR DOOR REMOVED R9 CORD & PLUG 650VA UPS MINIMUM UPS RECEPT. 24V PS CLOSE AUTO OPEN BACKPRESSURE VALVE OPEN SOLENOID R3 0OX SV B OPEN COMMAND R4 SV 0X0 W CLOSE COMMAND UTILITY OR MOV POWER FAILURE(AR1) DOOR INTRUSION ALARM(R6) MOV FAULT OR NOT IN AUTO(R7) MOV CLOSED(R8) MOV OPENED(R9) BACKPRESSURE VALVE NOT IN AUTO(R10) DIGITAL OUT 1) 2) 3) 4) MOV OPEN(R1) MOVE CLOSE(R2) OPEN BACK PRESSURE SUSTAINING VALVE(R3) CLOSE BACK PRESSURE SUSTAINING VALVE(R4) ANALOG+HART IN PRESSURE(ON HART) CALIBRATION DEVIATION WARNING(ON HART) CONFIGURE PER COUNTY DIRECTION(ON HART) CONFIGURE PER COUNTYS DIRECTIONON HART) A R10 PLC 10A-1P AB COMPACTLOGIX L23 120VAC SURGE SUPPRESSOR, EDCO HSP121 4. DATA SIGNAL LINE SURGE SUPPRESSOR, EDCO 5. 24VDC POWER SUPPLY, ALLEN BRADLEY 6. 24VDC UNMANAGED 4 PORT INDUSTRIAL SWITCH. 7. PLC 8. ETHERNET DATA CIRCUIT PROTECTOR. EDCO LCDP WITH RJ 45 JACKS. PROVIDE INDUSTRIAL GRADE RJ45 CONNECTORS. 9. DUPLEX GFI RECEPTACLE. 10. 110VAC CONTROL RELAY. R6-R10. 11. 24VDC CONTROL RELAY. TYPICAL UNLESS NOTED OTHERWISE. RELAYS R1-R5. 12. 120V, 1 POLE SQUARE D POWER BREAKER. PC642 SERIES 1606 SERIES 11 2. S P A C E PLC 7 EDCO 13 NETWORK SWITCH RKS Electrical, Instrumentation & Control Design HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 P.E. Certificate of Authorization #8212 NO. DATE REVISIONS FLOWMETER I/O IS NOT SHOWN ON THIS REFERENCE SPECIFICATION FOR DETAILED VIRTUAL I/O LIST. PROVIDE INDUSTRIAL GRADE ETHERNET CONNECTORS THROUGHOUT PANEL AND AT FIELD INSTRUMENT. PROVIDE ALL COMPONENTS NECESSARY AND REQUIRED BY MANUFACTURER FOR A FULLY FUNCTIONAL ETHERNET AND HART INSTRUMENT NETWORK WHETHER SPECIFICALLY SHOWN ON THIS DRAWING OR NOT. NEUT. GROUND 15 AMPS MAX EDCO L I N E L O A D AC NEUT. GROUND HSP121BT-1RU 3 BACK PLATE LAYOUT Consulting Engineers PE #62427 LABELED FOR A MINIMUM 10kA SCC. PROVIDE 250 OHM TERMINATING RESISTOR ON HART NETWORK FIELD INSTRUMENT END. NETWORKED PRESSURE TRANSMITTER AND 12 AC UPS RECEPT PANEL IS REQUIRED TO BE RATED AND DRAWING. 4. 2 10 GND. VALVE CONTROL PANEL ELEMENTARY TRACY PROKOPETZ 3. 5. 120 VAC UPS S P A C E WIREWAY 8 RELAYS AR1 AND 1. I/O EDCO MODULE, DUAL COMMUNICATION PORT PROCESSOR, DATA ACCESS TOOL, MEMORY MODULE WITH REAL TIME CLOCK, ETHERNET ADAPTER, BATTERY BACK-UP. NOT IN AUTO POWER MINIATURE BREAKER. 3. ALLEN BRADLEY COMPACTLOGIX 1769-L23QB1B WITH 4 POINT SPECTRUM 1769sc-IF4IH ANALOG+HART INPUT 120V, 1 POLE PHOENIX PUSH BUTTON CONTROL 6 GENERAL NOTES: TERMINAL BLOCKS NOT IN AUTO XX0 WIREWAY TERMINAL BLOCKS 1) 2) 3) 4) 2. DOOR CONTACT INTRUSION ALARM. PLUNGER TYPE CR CR CR CR CR CR BACKPRESSURE VALVE CLOSE SOLENOID 1) 2) 3) 4) 5) 6) # KEYNOTES 1. CR CR CR CR X00 DIGITAL IN 1 9 WIREWAY CONTROL VALVE 5 WIREWAY FLOW CONTROL IQ SERVICE CONNECTION I/O POINT LIST WIREWAY 10A-1P K:\CCUD IQ Telemetry\Priority 2\E6.dwg Plotted: Nov 14, 2011 - 9:55am by tracy SIDE FRONT WIREWAY 10A-1P EQUIPMENT BACK PLATE MOV OPENED MOV INTERNAL LOUVER R8 BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: E6.dwg COUNTY WATER-SEWER DISTRICT COLLIER COUNTY, FLORIDA TARPON COVE, CALUSA BAY & VINEYARDS ELEMENTARY VALVE CONTROL PANEL DETAILS AND ELEMENTARY PROJECT NO. : 2011.027 DATE : 11/11 SHEET NO. : E6 120 VOLTS FROM PANELBOARD L1 G N 20A-1P N 10A-1P AR1 30A-1P 120V AB COMPACTLOGIX L23 COMM RESET R6 TO MOV 5A-1P EDCO HSP-121 20A-1P TO FLOWMETER NETWORK SWITCH SPD 2A-1P 20A-1P CABINET PAINTED WHITE 36" X 48" X 12" MIN SIZE. PROVIDE WITH SUNSHIELD WITH WHITE POWDER COAT FINISH 24VDC POWER SUPPLY R7 DOOR INTRUSION SWITCH NEMA 3R STAINLESS STEEL HINGED 3 POINT LATCH CONTINUOUS STAINLESS STEEL HINGE FUSE INTERNAL LIGHT KIT WITH TERMINAL BLOCKS AND INTEGRALCONVENIENCE RECEPTACLE CONTROLLED AUTOMATICALLY VIA DOOR SWITCH VALVE CONTROL PANEL PANEL INT LT & RECEPT. LOUVER 4-20mA LOOP for HART PROT. UTIL. POWER 5A-1P 12VDC POWER SUPPLY G FUSE OPEN COMMAND COMM. FLT DATA RADIO A A MOV FAULT OR NOT IN AUTO R1 R2 MOV OPEN MOV CLOSE CLOSE COMMAND BACKPRESSURE SUSTAINING VALVE NOT IN AUTO W A CLOSE OPEN R8 AUTO UTILITY POWER COMMUNICATION FAULT A G MOV CLOSED MOV A B R5 MOV MOV FAULT OR NOT IN AUTO BACKPRESSURE VALVE R9 RESET COMMUNICATION MOV OPENED MOV R10 INTERNAL LOUVER 10A-1P 650VA UPS MINIMUM CORD & PLUG 13 12V PS 24V PS 5 BACK PLATE 1 14 9 NOTE: ELEVATION SHOWN WITH EXTERIOR DOOR REMOVED UPS RECEPT. 10A-1P 0OX X00 WIREWAY SV B OPEN COMMAND SV 0X0 EDCO R11 13 EDCO NOT IN AUTO NOT IN AUTO ANALOG+HART IN RKS Electrical, Instrumentation & Control Design P.E. Certificate of Authorization #8212 NO. DATE REVISIONS BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS PRESSURE(ON HART) CALIBRATION DEVIATION WARNING(ON HART) CONFIGURE PER COUNTY DIRECTION(ON HART) CONFIGURE PER COUNTYS DIRECTIONON HART) ALLEN BRADLEY COMPACTLOGIX 1769-L23QB1B WITH 4 POINT SPECTRUM 1769sc-IF4IH ANALOG+HART INPUT UPS RECEPT HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 PE #62427 1) 2) 3) 4) 12 AC Consulting Engineers MOV OPEN(R1) MOVE CLOSE(R2) OPEN BACK PRESSURE SUSTAINING VALVE(R3) CLOSE BACK PRESSURE SUSTAINING VALVE(R4) COMMUNICATION FAULT(R5) COMMUNICATION FAULT RESET(R6) NEUT. GROUND MODULE, DUAL COMMUNICATION PORT PROCESSOR, DATA ACCESS TOOL, MEMORY MODULE WITH REAL TIME CLOCK, ETHERNET ADAPTER, BATTERY BACK-UP. 15 AMPS MAX EDCO L I N E L O A D AC NEUT. GROUND HSP121BT-1RU 3 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: E7.dwg GENERAL NOTES: DOOR CONTACT INTRUSION ALARM. PLUNGER TYPE 1. 2. 2. 120V, 1 POLE PHOENIX PUSH BUTTON CONTROL 3. 120VAC SURGE SUPPRESSOR, EDCO HSP121 4. DATA SIGNAL LINE SURGE SUPPRESSOR, EDCO 4. 5. 24VDC POWER SUPPLY, ALLEN BRADLEY 5. 6. 24VDC UNMANAGED 4 PORT INDUSTRIAL SWITCH. 7. PLC 8. ETHERNET DATA CIRCUIT PROTECTOR. EDCO LCDP WITH RJ 45 JACKS. PROVIDE INDUSTRIAL GRADE RJ45 CONNECTORS. 9. DUPLEX GFI RECEPTACLE. 10. 110VAC CONTROL RELAY. R7-R11. 11. 24VDC CONTROL RELAY. TYPICAL UNLESS NOTED OTHERWISE. RELAYS R1-R6. 12. 120V, 1 POLE SQUARE D POWER BREAKER. 13. 12VDC POWER SUPPLY, ALLEN BRADLEY 14. DATA RADIO, INTEGRA-TR DIGITAL OUT BACK PLATE LAYOUT VALVE CONTROL PANEL ELEMENTARY UTILITY OR MOV POWER FAILURE(AR1) DOOR INTRUSION ALARM(R7) MOV FAULT OR NOT IN AUTO(R8) MOV CLOSED(R9) MOV OPENED(R10) BACKPRESSURE VALVE NOT IN AUTO(R11) # KEYNOTES 1. PLC GND. TRACY PROKOPETZ 1) 2) 3) 4) 5) 6) 1) 2) 3) 4) 5) 6) 120 VAC UPS DIGITAL IN 2 10 TERMINAL BLOCKS A XX0 WIREWAY W FLOW CONTROL IQ SERVICE CONNECTION I/O POINT LIST S P A C E WIREWAY 8 CLOSE COMMAND S P A C E PLC 7 TERMINAL BLOCKS K:\CCUD IQ Telemetry\Priority 2\E7.dwg Plotted: Nov 14, 2011 - 11:55am by tracy BACKPRESSURE VALVE CLOSE SOLENOID I/O CR CR CR CR CR CR R4 11 6 WIREWAY BACKPRESSURE VALVE OPEN SOLENOID R3 WIREWAY CLOSE AUTO CR CR CR CR CR CR OPEN SIDE FRONT WIREWAY CONTROL VALVE EQUIPMENT POWER MINIATURE BREAKER. PC642 SERIES 1606 SERIES 3. PANEL IS REQUIRED TO BE RATED AND LABELED FOR A MINIMUM 10kA SCC. PROVIDE 250 OHM TERMINATING RESISTOR ON HART NETWORK FIELD INSTRUMENT END. NETWORKED PRESSURE TRANSMITTER AND FLOWMETER I/O IS NOT SHOWN ON THIS DRAWING. REFERENCE SPECIFICATION FOR DETAILED VIRTUAL I/O LIST. PROVIDE INDUSTRIAL GRADE ETHERNET CONNECTORS THROUGHOUT PANEL AND AT FIELD INSTRUMENT. PROVIDE ALL COMPONENTS NECESSARY AND REQUIRED BY MANUFACTURER FOR A FULLY FUNCTIONAL ETHERNET AND HART INSTRUMENT NETWORK WHETHER SPECIFICALLY SHOWN ON THIS DRAWING OR NOT. RELAYS AR1 AND 1606 SERIES COUNTY WATER-SEWER DISTRICT COLLIER COUNTY, FLORIDA VETERANS PARK VALVE CONTROL PANEL DETAILS AND ELEMENTARY PROJECT NO. : 2011.027 DATE : 11/11 SHEET NO. : E7 GREEN INSULATED WIRE AWG 18 CONTINUOUS STAINLESS STEEL HINGE OUTER JACKET NEMA 4X ST.STEEL CABINET PANINTED WHITE FOR EXTERIOR LOCATIONS. NEMA 1 STEEL CABINET FOR INTERIOR LOCATIONS. AS REQUIRED WRAPPED SHIELD CRIMPED SPLICE CONNECTOR 12" AS REQUIRED OUTER JACKET SHIELD OUTER JACKET INTERNAL EQUIPMENT BACK PLATE INTEGRAL FLOW METER TRANSMITTER (REQUIRED SUNSHIELD NOT SHOWN) RING (TYP.) 3/8" ALUMINUM PLATE WITH 3/8" U-BOLTS SIZED FOR EQUIP. FLOW TERMINATION OF SHIELDED INSTRUMENT & CONTROL CABLE N.T.S. MOUNTING SIDE FRONT FIELD SURGE SUPPRESSION, DISCONNECT, CONTROL AC NEUT. GROUND L O A D REQUIRED CAST IRON TRAFFIC COVER 18" 9.5" TYPE "TA" CADWELD CONNECTION GROUND FIELD WIRING PROVIDED BY ELECTRICAL CONTRACTOR. ETHERNET ETHERNET TO TO PLC INSTRUMENT UNDERGROUND CONDUIT INSTALLATION N.T.S. NOTE: ALL MOUNTING HARDWARE TO BE STAINLESS STEEL. USE WASHERS AND SPLIT LOCK-WASHERS UNDER ALL NUTS. ETHERNET INSTRUMENT SURGE SUPRESSION N.T.S. PLC CABINET COPPER GROUND CABLE 13.5" 22" OLD CASTLE CONCRETE BOX SERIES MB37 GROUND CABLE CONNECTION N.T.S. 2-WIRE FIELD TRANSMITTERS 2 CU. FT. CRUSHED ROCK SCH 40 ALUM. CONCRETE SUPPORT PAD TYPICAL STEEL GRD. ROD, THREE SECTION ROD CADWELDED TOGETHER. SCH 80 PVC 20'-0" LONG TYPICAL GROUND ROD INSTALLATION DETAIL N.T.S. RKS Consulting Engineers Electrical, Instrumentation & Control Design HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 P.E. NO. DATE MOV WITH INTEGRAL CONTROL INSTALLATION DETAIL (TYPICAL ALL GROUND RODS) TYPICAL GROUNDROD CONNECTION N.T.S. Certificate of Authorization #8212 DRAWING SYMBOL REVISIONS BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS N.T.S. 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: E8.dwg 120 V. POWER DISTRIBUTION STAINLESS STEEL CHANNEL 24" X 24" X 10" 5/8" DIA X 20' COPPER ENCASED (5/8"x10') EACH. FROM INSTRUMENT CASE TO GROUND ROD & NEAREST GROUND GRID. TYPICAL. WIRE TO GROUND ROD & GROUND GRID. TYPICAL COUNTERPOISE NO. 605 COPPER COUNTERPOISE NO. 94-10S SECTIONAL COPPER CLAD GROUND ANALOG FIELD INSTRUMENTS #2 SOLID TINNED GROUND WIRE #2 SOLID TINNED GROUND 2' MAXIMUM. 4-20 MA #2/0 TINNED COPPER 6" NO. 203-G5 GROUND ROD COUPLING INSTRUMENT CABLE. TWISTED SHIELDED 4-20 MA SEAL TIGHT CONDUIT CADWELD TO TOP OF ROD. 18" CADWELD MOLD GTC-168C WITH CARTRIDGE #150 LIGHTNING/SURGE SUPPRESSOR 4-20MA SUPPRESSOR LOCATED NEXT TO THE INSTRUMENT TO PLC M.O.V. 36X36X12"D REINFORCED TYPICAL DEVICE MOUNTING DETAIL N.T.S. 12" NOTE: PROVIDE CONCRETE SLAB IN AREAS WITHOUT SUITABLE STRUCTURE FOR MOUNTING PEDESTAL. 120V 120V TO TO INSTRUMENT CP GROUND CABLE SHIELD AT THIS END ONLY K:\CCUD IQ Telemetry\Priority 2\E8.dwg Plotted: Nov 14, 2011 - 9:55am by tracy BASE PLATE AS DETAILED FLOOR OR PLATFORM GND. ALLEN BRADLEY RJ45 TO M12 BULKHEAD ADAPTER MARKED "GROUND" SAND BACKFILL PE #62427 AND FLOOR FLANGE 6" MIN SCHEDULE 80 PVC TRACY PROKOPETZ 48" FOR CONTROL STATIONS GROUNDING OF MAGNETIC FLOW ELEMENT WITH INTEGRAL TRANSMITTER. N.T.S. SIZE AS HSP121BT-1RU LCDP ALLEN BRADLEY PATCHCORD WITH INDUSTRIAL GRADE RJ45 CONNECTORS INTERNAL WIRING PROVIDED BY PANEL SUPPLIER #2 CU SOLID TINNED TO COUNTERPOISE 30" MIN; 36"FOR SERVICE CONDUCTORS 15 AMPS MAX EDCO L I N E 12" MIN EQUIPMENT. EDCO CONNECTION TO BE MADE BY EXOTHERMIC WELD. 2" ALUMINUM PIPE CL DEVICE OR ELECTRICAL #2 CU SOLID TINNED METALLIZED WARNING TAPE ENTIRE LENGTH OF CONDUIT. PANEL, WIRING GROUND RING #2 CU SOLID TINNED FINISHED GRADE BASE PLATE DETAIL N.T.S. AC GROUND LEAD NOTE: SHIELD GROUNDED AT TERMINATION 12" NEUT. SHRINK TUBING PROVIDE ETHERNET SURGE SUPPRESSION AS DETAILED ON INSTRUMENT SURGE SUPRESSION DETAIL. GROUND CEMENT GROUT (TYP) PLAN 120 VAC SIGNAL LEADS LUG. TYPICAL 1/2" CINCH ANCHOR BOLTS AND NUTS SHIELD SHRINK TUBING ALUMINUM BASE PLATE 1 1/2" (TYP) COVER THIS PORTION WITH SHRINK TUBING 2" ALUMINUM PIPE OR 6" CHANNEL 1/2" PLATE 60" FOR TRANSMITTERS, ETC. COVER THIS PORTION WITH SHRINK TUBING AC POWER AND ETHERNET SURGE SUPPRESSORS (LOCATED NEXT TO THE INSTRUMENT) 120 V.A.C. ETHERNET FIELD INSTRUMENTS PLC CABINET TO PLC INSTRUMENT CABLE. CAT 5e M12 TWISTED UNSHIELDED. SURGE SUPPRESSOR #2 SOLID TINNED GROUND WIRE CAT 5e M12 PATCHCORD FROM INSTRUMENT CASE TO GROUND ROD & NEAREST GROUND GRID. TYPICAL. ETHERNET FIELD TRANSMITTERS INSTRUMENTATION GROUNDING & SURGE PROTECTION N.T.S. COUNTY WATER-SEWER DISTRICT COLLIER COUNTY, FLORIDA ELECTRICAL DETAILS PROJECT NO. : 2011.027 DATE : 11/11 SHEET NO. : E8 VARIES PROPOSED VALVE CONTROL PANEL PROPOSED VALVE CONTROL PANEL 2" SCH40 GALVANIZED STEEL PIPE END CAP PCTEL MAXRAD UNITY GAIN OMNI MODEL 4500 NEMA 4X SS SERVICE ENTRANCE RATED ENCLOSED BREAKER OR EQUAL. 6" X 6" X 10' MINIMUM NEMA 4X SS SERVICE ENTRANCE RATED ENCLOSED BREAKER PRECAST CONCRETE POST M STAINLESS STEEL U-STRUT CHANNEL SUPPORT. INSTALL WITH STAINLESS STEEL HARDWIRE LENGTH IT 6' MIN. AS REQUIRED BY EQUIPMENT BAND-IT S.S. TIE SS WRAPS 18" O.C. MAIN SERVICE SURGE SUPPRESS. PVC SLEEVE AROUND CONDUIT FOR PROTECTION SQUARE D XR SERIES, 80KA. 2" SCH40 STEEL PIPE (TYPICAL) #2 SOLID TINNED. FINISH GRADE HEAVY DUTY PC TEL MMK12 MOUNTING BRACKET FPL APPROVED METER SOCKET COAX CABLE LMR-400-DB FINISH GRADE COAX CABLE SERVICE LOOP 10'-0" FPL APPROVED METER SOCKET CONTRACTOR TO MOUNT FIBER INTERFACE BOX PROVIDED BY COLLIER COUNTY IT. COORDINATE BOX LOCATION AND FIBER CONDUIT ROUTING WITH COUNTY PM AND IT TO AVOID CONFLICT WITH THIS PROJECT. FIBER OPTIC CONDUTI AND CABLE INSTALLATION BY OTHERS. CONTRACTOR TO MOUNT FIBER INTERFACE BOX PROVIDED BY COLLIER COUNTY IT. COORDINATE BOX LOCATION AND FIBER CONDUIT ROUTING WITH COUNTY PM AND IT TO AVOID CONFLICT WITH THIS PROJECT. FIBER OPTIC CONDUIT AND CABLE INSTALLATION BY OTHERS. HEATSHRINK COAX CONNECTION HERE 4' MIN. CONCRETE 3000 PSI UNDISTURBED SOIL G SIDE VIEW N.T.S. TYPICAL SCH .80 PVC CONDUIT TO CONTROL PANEL 5/8"DIA. X 20' COPPERWELD GND. ROD PIPING ASSEMBLY COUNTERPOISE SYSTEM. CONTRACTOR TO MOUNT FIBER INTERFACE BOX PROVIDED BY COLLIER COUNTY IT. COORDINATE BOX LOCATION AND FIBER CONDUIT ROUTING WITH COUNTY PM AND IT TO AVOID CONFLICT WITH THIS PROJECT. FIBER OPTIC CONDUIT AND CABLE INSTALLATION BY OTHERS. FRONT VIEW N.T.S. 2' SQ. CONCRETE BASE BACK VIEW N.T.S. MINIMUM PROVIDE AS DESIGNED FOR WIND LOADING DETAILED BELOW GROUND LEVEL SERVICE ENTRANCE RATED ENCLOSED CIRCUIT BREAKER DETAIL #2 TOWER TOP DETAIL N.T.S. 20' X 5/8" COPPER GROUND ROD IN HANDHOLE. SEE GROUNDING PLAN. 6" FPL APPROVED METER SOCKET VALVE CONTROL PANEL TO CONTROL PANEL M 3'0" 1" PVC CONDUIT STREAMER RETARDING AIR TERMINAL STREAMER RETARDING AIR TERMINAL PLAN VIEW N.T.S. 6" TYPICAL EQUIPMENT RACK DETAIL HEAVY DUTY 2-BOLT LOCKABLE COVER WITH FINISHED GRADE "ELECTRIC" ENGRAVED LETTERS WITH 1" STRAIN RELIEF ON TOP OF STUBBED CONDUIT FOR COAX CABLE GROUND CLAMP #2/0 STRANDED TINNED COPPER GROUND WIRE 10" REFER TO INDIVIUAL SITES FOR REQUIRED EQUIPMENT N.T.S. 1" CONDUIT MOUNTED IN FRONT OF TOWER LEG AS SHOWN IN CONDUIT DETAIL TOP OF CONCRETE TOWER HEIGHT- SITE AFG VETERANS PARK 10' CAD WELD BELOW GRADE TO NEAREST GROUND ROD ANTENNA UNITY GAIN OMNI GROUND ROD REF. BONDED TO CONTROL PANEL GROUND GRID NOTE: PROVIDE 36X36X12"D REINFORCED CONCRETE SLAB IN AREAS WITHOUT SUITABLE STRUCTURE FOR MOUNTING PEDESTAL. PULLBOX SHALL BE RTU ANTENNA DETAIL N.T.S. QUAZITE COMPOSOLITE NON-CONCRETE OR APPROVED EQUAL PROVIDE 6" DEPTH OF 2" ALUMINUM PIPE 48" SEPARATE SIGNAL AND POWER CONDUIT TO INSTRUMENT TRANSMITTER K:\CCUD IQ Telemetry\Priority 2\E9.dwg Plotted: Nov 14, 2011 - 3:16pm by tracy SHOWN ON DRAWINGS; MINIMUM SIZE 20"L X 14"W X 12"D PEA GRAVEL FOR DRAINAGE. POWER AND SIGNAL SURGE SUPPRESSION. AS DETAILED RUBBER GASKET AROUND NIPPLES EXISTING SLAC UNIT ENCLOSURE DETAIL #1 GROUNDING DETAIL N.T.S. COMPOSOLITE PULLBOX WITH OPEN BOTTOM SIZE AS SURGE SUPPRESSOR EQUAL TO EDCO TYPE SS-65 SERIES CLOSE NIPPLE DIRECT TO TRANSMITTER. 1000 HANDHOLE/PULLBOX DETAIL 12"X12"X1/4" ALUMINUM PRESSURE INDICATING TRANSMITTER N.T.S. PLATE U-BOLT TO PIPE FLEX CONDUIT TYPICAL 1/2" FLUID FILLED FLOW THROUGH S.S. U-STRUT SUPPORTS TYP. PRESSURE SEAL, 100% CIRCUMFERENTIAL 120V POWER CONDUIT SENSING WITH PORT DIAMETER EQUAL TO CONCRETE FOUNDATION REF. ETHERNET SIGNAL CONDUIT #6 INSULATED BOND WIRE PRESSURE TRANSMITTER CONNECTION, RED VALVE TYPE 42 PRESSURE SENSOR, 316 SS, BUNA-N SLEEVE. 1/2" SS WHERE EXPOSED; BARE IF EMBEDDED; FROM/TO ALL UNION CONTROL PANELS AND INSTRUMENTS AND TO 20' TOWER REF. GROUND RODS OR PERIMETER GROUND SYSTEM. 24"MIN. CONCRETE FLOOR 1/2" SS QUARTER TURN BALL VALVE. FROM PIPE SADDLE N.O. LIGHTNING MASTER MODEL 1/2" SS QUARTER PP-32M OR EQUAL STREAMER RETARDING TERMINAL 1.5" TURN BALL VALVE WITH THD PLUG FOR FLUSHING AND CALIBRATION. N.C. 5/8"X 20' DRIVEN COPPERCLAD ROD WEST ELEVATION 1" PVC CONDUIT OFFSET NORTH ELEVATION FROM FRONT OF TOWER INSTRUMENT ELECTRICAL INSTALLATION DETAIL N.T.S. FLAT ROOF AIR TERMINAL N.T.S. RKS Consulting Engineers Electrical, Instrumentation & Control Design HOLE MONTES 15400 Shamrock Dr. Fort Myers, Fl. 33912 TRACY PROKOPETZ PE #62427 P.E. Certificate of Authorization #8212 NO. DATE REVISIONS BY ENGINEERS PLANNERS SURVEYORS LANDSCAPE ARCHITECTS 950 Encore Way Naples, FL. 34110 Phone: (239) 254-2000 Florida Certificate of Authorization No.1772 CONDUIT DETAIL TOP VIEW N.T.S. DESIGN BY: T.M.P. DRAWN BY: T.M.P. CHECKED BY: T.M.P. CAD FILE: E9.dwg PRESSURE TRANSMITTER INSTALLATION DETAIL (TYP.) COUNTY WATER-SEWER DISTRICT COLLIER COUNTY, FLORIDA RTU ANTENNA & ELECTRICAL DETAILS PROJECT NO. : 2011.027 DATE : 11/11 SHEET NO. : E9
© Copyright 2024