for C11200 (Picosecond Fluorescence Lifetime Measurement System) Universal sample compartment A8110 Including optics, base plate and sample holder *The A8110 used in combination with organic chemistry samples (solution and film) holder A8114 Features Overview The A8110 is an universal sample compartment designed exclusively for the C11200 Picosecond Fluorescence Lifetime Measurement System. The A8110 can be easily mounted on an optical bench (with M6 holes at 50 mm pitch) or any convenient bench using the A8111 base plate. Interchangeable sample holders are available for cryostat, semiconductor wafers, organic chemistry samples (solution and film), and dewar units. To ensure the superb reproducibility, the optical axis stays the same position even when interchanging sample holders or mounting/removing samples. ● Four types of sample holders available • Cryostat holder: A8112 -01, -02 • Semiconductor wafers holder: A8113 • Organic chemistry samples (solution and film) holder: A8114 Dewar units: A8790 • ● High fluorescence collection efficiency About 5 times brighter than conventional bifurcated fiber optics ● Excellent optical-axis reproducibility Optical axis reproducibility when attaching/removing samples: within 100 μm Applications ● Excitation from either the left or right side ● Fluorescent spectral photometry ● FC connector input for excitation ● Phosphorescent spectral photometry ● Compatible with standard Ti-Sapphire laser, etc. Example of system configuration ● External-laser excitation measurement system ● Nitrogen-laser excitation measurement system Picosecond Fluorescence Lifetime Measurement System C11200 Picosecond Fluorescence Lifetime Measurement System C11200 Streakscope C10627 Mount Table A5206-08 Streakscope C10627 Spectrograph C11119-01 Mount Table A5206-08 Spectrograph C11119-01 A8110-01,-02 A8110-01,-02 Optical Trigger Unit Nitrogen Laser C4792 Base plate A8111 Organic chemistry samples (solution and film) holder A8114 Optical fiber with both ends of FC connector Base plate A8111 External laser (Mode-locked Ti-Sapphire laser, etc.) Organic chemistry samples (solution and film) holder A8114 Components Part Number Product name Standard optics (over 370 nm) A8110-01 Standard optics for UV (over 200 nm) A8110-02 Base plate A8111 DN1704 cryostat holder A8112−01 (OXFORD INSTRUMENTS Cryostat) Optistat DN cryostat holder A8112−02 (OXFORD INSTRUMENTS Cryostat) Semiconductor wafers holder (Supports 3 inch wafers; comes supplied with vacuum chuck) A8113 Organic chemistry samples (solution and film) holder A8114 (10 mm square cell, 20 mm square film) ▲ DN1704 cryostat holder A8112-01 Dewar units (Liquid nitrogen cooling; three 10 mm square wafer samples can be mounted simultaneously.) ▲ Semiconductor wafers holder A8113 A8790 Unit: mm Base plate A8111 Spectrograph adapter 850±5 Mount table A5206-08 Light collection optics ● Standard optics A8110 • Excitation optics • Light collection optics • Base plate for sample holder ● Organic chemistry samples (solution and film) holder A8114 • Sample holder • 10 mm square cell holder • Film holder • Pseudo holder Excitation optics ● Base plate 1000±5 Base plate for sample holder 10 280±5 160±2 Organic chemistry samples (solution and film) holder A8114 ▲ Organic chemistry samples (solution and film) holder A8114 ▲ Dewar unit A8790 ● Subject to local technical requirements and regulations, availability of products included in this promotional material may vary. Please consult with your local sales representative. ● Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions. Specifications and external appearance are subject to change without notice. © 2009 Hamamatsu Photonics K.K. Homepage Address http://www.hamamatsu.com HAMAMATSU PHOTONICS K.K., Systems Division 812 Joko-cho, Higashi-ku, Hamamatsu City, 431-3196, Japan, Telephone: (81)53-431-0124, Fax: (81)53-433-8031, E-mail:[email protected] U.S.A. and Canada: Hamamatsu Corporation: 360 Foothill Road, Bridgewater, N.J. 08807-0910, U.S.A., Telephone: (1) 908-231-0960, Fax: (1)908-231-0852, E-mail: [email protected] Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49)8152-375-0, Fax: (49)8152-2658, E-mail: [email protected] France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: (33)1 69 53 71 00, Fax: (33)1 69 53 71 10, E-mail: [email protected] United Kingdom:Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire, AL7 1BW, U.K., Telephone: (44) 1707-294888, Fax: (44) 1707-325777, E-mail: [email protected] North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171-41 Solna, Sweden, Telephone: (46)8-509-031-00, Fax: (46)8-509-031-01, E-mail: [email protected] Cat. No. SHSS0009E01 Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E 20020 Arese (Milano), Italy, Telephone: (39)02-935 81 733, Fax: (39)02-935 81 741, E-mail: [email protected] DEC/2009 HPK Created in Japan
© Copyright 2024