General Characteristics Notes MIURA 200

Characteristics
Notes
MIURA 200
General
Instrument Type
Type
Floor standing & Bench top
P.C.
Separate
Yes
Open/Close system
ise module
open/closed with smart card
On-board
ise parameters
Throughput/hour
yes/optional
Na+, K+, Cl-, Li+
Without ISE
160
With ISE
250
Number of sampling Arms
1
Reagents on line
up to 49
Methods off line
more than 200
Sample Treatment
Sample support in the analyser
Positions
50 + 50 dilution cups
Paediatric sample support in the
analyser
Calibrators
Positions
6
Positions
18
Controls
Positions
3 (Levy-Jennings Graph / 3-levels)
Bar-code reader
On-board
yes/optional
Sample primary tube types
Without adapter
Ø12÷16mm × 75÷100mm
Cups
with adapter
3ml sample cups
Dead Volume
12/13mm primary tube
100µl
16mm primary tube
200µl
3ml sample cup
50µl
Sample Volume (µl)
Min. max.
1 / 100 µl
Dilution of patient sample
Pre-dilution
automatic on request
Post-dilution / rerun
automatic on request
Automatic standard curve dilution
Diluter
yes, up to 8-points
Micro-metering pump
stainless steel plunger
Characteristics
Liquid level sensor
Notes
Capacitive
Shock sensor
MIURA 200
yes
yes
Reagent Treatment
Reagent support in the analyser
Positions
48 + 1 diluent
Bar-code reader
On-board
yes/optional
Reagent bottles
Without adapter
50ml
Without adapter
20ml
50ml bottle
1,5ml
20ml
0,5ml
Min. max.
180 / 400 µl
Dead Volume
Reagent Volume (µl)
Diluter
Liquid level sensor
Micro-metering pump
Capacitive
yes
Shock sensor
yes
Reagents to be used per test
3
Reagent cooling
14°C below ambient temp
Multiple reagent position (same lot)
yes
Analytical methods
end-point, bi-chromatic end-point, fixed-time, kinetic, differential sample blank, differential 2-reagents
Cuvette Treatment
Reaction/Reading Volume (µl)
Typical
200 µl
Cuvettes on board
Cuvette plate
80 (re-washable)
Cuvettes type
optical plastic (Bionex®)
Incubation heater
37°C ± 0.1°C controlled
Cuvette Washing Station
yes, over 8 steps
Measurement System
Photometer Type: Light Source
Lamp
Type of Measurement
Wavelenghts
Halogen lamp (2,000hours)
mono or bichromatic
Interferential filters
Photometric linearity
340÷700nm, 8 on board + 1 free
0÷3 O.D.
Installation and Use of Analyser
Water Consumption
Over 1 hour (typ)
3 liters
Liquid tanks
systemic sol. tank , cleaner sol.tank , waste tank
Tank level sensor
yes
Control System
Operating System
Windows XP® Pro
Characteristics
Notes
MIURA 200
L.I.S. connection
yes, optional
Patient archive
yes, up to 15,000 patients
Q.C. archive
yes, up to 5,000 tests