Characteristics Notes MIURA 200 General Instrument Type Type Floor standing & Bench top P.C. Separate Yes Open/Close system ise module open/closed with smart card On-board ise parameters Throughput/hour yes/optional Na+, K+, Cl-, Li+ Without ISE 160 With ISE 250 Number of sampling Arms 1 Reagents on line up to 49 Methods off line more than 200 Sample Treatment Sample support in the analyser Positions 50 + 50 dilution cups Paediatric sample support in the analyser Calibrators Positions 6 Positions 18 Controls Positions 3 (Levy-Jennings Graph / 3-levels) Bar-code reader On-board yes/optional Sample primary tube types Without adapter Ø12÷16mm × 75÷100mm Cups with adapter 3ml sample cups Dead Volume 12/13mm primary tube 100µl 16mm primary tube 200µl 3ml sample cup 50µl Sample Volume (µl) Min. max. 1 / 100 µl Dilution of patient sample Pre-dilution automatic on request Post-dilution / rerun automatic on request Automatic standard curve dilution Diluter yes, up to 8-points Micro-metering pump stainless steel plunger Characteristics Liquid level sensor Notes Capacitive Shock sensor MIURA 200 yes yes Reagent Treatment Reagent support in the analyser Positions 48 + 1 diluent Bar-code reader On-board yes/optional Reagent bottles Without adapter 50ml Without adapter 20ml 50ml bottle 1,5ml 20ml 0,5ml Min. max. 180 / 400 µl Dead Volume Reagent Volume (µl) Diluter Liquid level sensor Micro-metering pump Capacitive yes Shock sensor yes Reagents to be used per test 3 Reagent cooling 14°C below ambient temp Multiple reagent position (same lot) yes Analytical methods end-point, bi-chromatic end-point, fixed-time, kinetic, differential sample blank, differential 2-reagents Cuvette Treatment Reaction/Reading Volume (µl) Typical 200 µl Cuvettes on board Cuvette plate 80 (re-washable) Cuvettes type optical plastic (Bionex®) Incubation heater 37°C ± 0.1°C controlled Cuvette Washing Station yes, over 8 steps Measurement System Photometer Type: Light Source Lamp Type of Measurement Wavelenghts Halogen lamp (2,000hours) mono or bichromatic Interferential filters Photometric linearity 340÷700nm, 8 on board + 1 free 0÷3 O.D. Installation and Use of Analyser Water Consumption Over 1 hour (typ) 3 liters Liquid tanks systemic sol. tank , cleaner sol.tank , waste tank Tank level sensor yes Control System Operating System Windows XP® Pro Characteristics Notes MIURA 200 L.I.S. connection yes, optional Patient archive yes, up to 15,000 patients Q.C. archive yes, up to 5,000 tests
© Copyright 2024