l System Integrations l Process Analytics l Gas Generators l Sampling Conditioning Systems l Water Analytics Sample Gas Conditioner JCC FEATURES uStable dew point +3°C..+/- 0,2°C uAmbient temperature + 5 ... +45°C (50°C) uProportional temperature & pressure control uBuilt-in pump & condensate discharge pump uDigital temperature display and flowmeter uHigh performance heat exchanger uProven and reliable technology uCompact and robust u100% environmentally friendly (CFC free) GENERAL The JCC Sample Gas Conditioner is designed to lower the sample dew point and supply dehumidified sample gas with a pump to the moisture intolerant analysis equipment. The operation capability at high ambient temperature enables also applications i.e. in boiler houses. friendly R134a. The high performance heat exchanger guaranties maximum heat transfer rate and leak free operation. A built-in condensate discharge pump removes continuously the condensate and respectively a sample filter the impurities. TECHNICAL A constant dew point independent of varying sample specifications and ambient temperature is ensured by an improved proportional temperature & pressure control . The cooling system features a continuously running non-CFC compressor motor filled with environmentally FEATURES The JCC Sample Gas Conditioner features a single or dual gas path made of PVDF. A flowmeter allows the adjustment of the required flow rate. A digital temperature display, an isolated contact and interlocked pump provide unattended trouble free operation. Technical Data: Gas flow rate: 100Nl/h one gas path 200Nl/h two gas paths Gas inlet dew point max.: 65°C Gas inlet temp. max.: 140°C Gas outlet dew point: +3°C (factory set point) Dew point stability: +/-0.2°C Ambient temperature: +5....+45°C (50°C) Cooling power: 160W at ambient 25°C; evaporationtemp. 0°C Dead volume: approx. 160 ccm (60ccm heat exchanger) Condensate discharge: 1 cond. pump / gas path capacity 300ml/h Gas filter: one way filter 1mµ Nylon /Borosilicatefibre Flowmeter: Flowmeter range: Operating control: with needle valve PP/Glass/PVDF 10..100Nl/h / 15..150Nl/h Digital indication of heat exchanger temperature Built-in temp. alarm with potential free switch over contact, rating 250VAC 2A with cable, interlocked pump at >8°C Gas inlet: Fitting DN4/6 PVDF Gas outlet: Fitting DN4/6 PP 2 x 3p cable 2m; Mains; Status steel sheet; coated RAL 7035 430 x 225 x 300mm (WxDxH) approx. 20kg Contact rating: Gas connection: Mains: Housing: Dimension: Weight: Gas Flow Gaslaufplan Gas flow schematic 1 3 4 Gaslaufplan Gas flow schematic OUT 5 6 1 3 1 4 5 OUT 1 2 3 4 5 6 6 IN IN 2 2 CONDENSATE 2 Heat exchanger Peristaltic pump Diaphragm pump Condensate sensor (Option) Filter Flowmeterw. needle valve CONDENSATE Dimension Basic SAMPLEIN 16 27 7,6 483 ( 19" ) 465 R 354 ( 8HU ) 182 5 SAMPLEOUT POWERCORD STATUSCORD 4 40 431 Typ J C C - Housing Gas path Fine dust filter Wall mounting on rear panel L Wall mounting on side panel Q 19" Rack mounting R WWT-1 gas path; PVDF 1 Condensate pump 1 WWT-2 gas path; PVDF 2 Condensate pumps 4 One way filter 1 Special on request 2 Gas Sample pump <200Nl/h Gas flow control Flowmeter PE w. needle valve 10..100Nl/h 1 Flowmeter PE w. needle valve 15..150Nl/h 3 Condensate detector Power supply 2 Without 0 With KW-1 (interlocks pump by condensate breakthrough) 1 230V 50Hz 1 230V 60Hz 2 115V 50Hz 3 115V 60Hz 4 JCT Analysentechnik GmbH Werner Heisenberg-Straße 4 A-2700 Wiener Neustadt Tel. +43 (0) 2622 / 87201 Fax +43 (0) 2622 / 872011 E-Mail: [email protected] Web: www.jct.at 01/02
© Copyright 2024