WALK-AWAY OSMOMETRY - FULLY AUTOMATIC THE SMALLEST SAMPLE SIZE smometry is fast becoming O the chosen method for providing extremely accurate osmolality measurements in clinical, industrial and research settings. In the measurement of osmolality, freezing-point depression is the most sensitive and precise method available. Only the Fiske® 2400 MultiSample Osmometer gives you freezing-point technology, automated sample handling for up to 20 samples, and requires only a 20µL sample size. The Fiske 2400 Multi-Sample Osmometer is a valuable clinical tool, providing your laboratory with multiple functions: toxin screening, osmotically-active concentration monitoring, hyponatremia evaluation, and urine and stool analysis. The Fiske 2400 Multi-Sample Osmometer delivers the most precise test results...every sample, every run. Applications: • Clinical Medicine • Medical Research • IVD Test Development • Bio-Processor Control • Bio-Pharmaceutical Monitoring • Exercise Physiology and Athletic Conditioning Contact Advanced Instruments or visit our website for these and other unique osmometry applications. 03/03 2258SP Maximizes Productivity Records Results The Fiske 2400 Multi-Sample Osmometer tests up to 20 samples without supervision, allowing your valuable personnel to concentrate on other tasks. Test results appear automatically on the screen and the built-in printer provides a permanent record of each test result. RS-232C port is available for communication through a PC. Minimizes Sample Requirements Reduces Operating Costs Requiring only a 20µL sample, the Fiske 2400 delivers results with the smallest sample size of any automated osmometer. Fiske Associates’ long-standing history of consistently dependable performance keeps facilities worldwide up and running, minimizing operating costs. Simplifies Operation Worldwide Support With the push of a button, all calibration adjustments are made by the onboard microprocessor. Fiske Associates Hot-Line® Service and worldwide dealer network provide comprehensive customer service and technical support. Works On Your Schedule A test sequence can be interrupted to run a stat sample without affecting the ongoing process. FISKE® 2400 MULTI-SAMPLE OSMOMETER Clinical Applications of Osmometry Calculating Osmotic Gap – determine accuracy of calculated osmolality systems Mannitol Treatment – monitor appropriate mannitol usage when treating brain swelling Glycine Ingestion – estimate absorbtion of irrigation fluid Toxin Ingestion – identify osmolality effects from toxin ingestion Renal System Function – evaluate kidney concentration capability and monitor ADH therapy Body Hydration – identify peak hydration levels for improved athletic performance Other related products: In order to obtain peak performance and long life from your osmometer, learn more about these related products: Clinitrol™ 290 Reference – routinely checks calibration stability. Protinol® Near-Serum Reference – in 3 levels, gives added confidence at survey time. Linearity Set™ – documents performance for CLIA guidelines. Advanced® Calibration Standards and Sample Kits – are manufactured to exacting tolerances to keep your osmometer operating in peak performance. Accept no substitute. Renol™ Urine Controls – in two levels, manufactured to extremely tight tolerences for better repeatability and precise control. Model 2400 Multi-Sample Osmometer Specifications Sample Volume 20µL Test Time 90 seconds per sample typical Sample Throughput 35 to 40 tests per hour Sample Capacity Up to 20 samples Units mOsm/kg H2O Resolution 1 mOsm/kg H2O Range 0 to 2000 mOsm/kg H2O Communications DTE RS-232 Performance at Reference Conditions1 Linearity < 1% of straight-line between calibration points of 50 and 850 mOsm/kg H2O. Within 1.5% above 850 mOsm/kg H2O. Repeatability ± 3 mOsm/kg H2O (1 S.D.) between 0 and 400 mOsm/kg H2O; ± 0.75% (1 S.D.) between 400 and 2000 mOsm/kg H2O Drift Less than 1 mOsm/kg H2O per month Performance Over Operating Conditions Temperature Effects Less than 1 mOsm/kg H2O per 5°C (9°F) ambient temperature change Operating Conditions Temperature 18 to 35°C (64 to 95°F) Relative Humidity 30 to 80% Storage Temperature -40 to +45°C(-40 to +113°F) Electrical: Voltage 100 to 130 VAC (60 Hz) or 200 to 250 VAC (50 Hz) Power Consumption 150 Watts Memory Backup Integral lithium cell; 2 years minimum, 10 years maximum Dimensions 11"H x 17.5"W x 13.5"D (28cm x 44.5cm x 34 cm) Net Weight 23 lbs. (10.5 kg) Shipping Weight 33 lbs. (15 kg) Warranty One year limited warranty on workmanship and parts Certification Reference Conditions: 1 Available from: 20 to 25°C (68 to 77°F); 40 to 60% Relative Humidity; tolerances of reference or calibration solutions excluded Hot-Line® Technical Service Fiske Associates Hot-Line® Service and worldwide dealer network provide comprehensive customer service and technical support. For more information on Fiske products or any of the Advanced Instruments family of tests, please call: 800-225-4034
© Copyright 2024