System Components and Accessories for Sample Gas Conditioning Data Sheet 10/235.20 EN January 2004 A gas analysis system usually consists of two groups of devices: • The gas analyzer measures the concentrations of the sample gas components and converts them into an electrical signal. • Supplementary devices sample the sample gas from the process, condition it and feed it in the gas analysis system. Contents In most cases, the sample gas sampled from the process cannot be processed by the gas analyzer without further conditioning. Too high a dust content, temperature and dew point as well as too high or too low pressure, and not least interference components in the sample gas can impair the operational capability of the gas analyzer and falsify the measuring result. Supplementary devices such as the sampling probe, the sample gas line, the sample gas cooler and pumps and filters ensure that the sample gas inlet conditions of the connected gas analyzers are satisfied and faultless measuring results are obtained independently of the process sequence and the local conditions. SCC-C Sample Gas Cooler SCC-F Sample Gas Feed Unit SCC-E Sample Gas Feed Unit Electrical Cool Trap CGKA 2 Automatic Condensate Drain CGMF 2 Sample Gas Feed Unit Diaphragm Pump 4N Diaphragm Pump 2 Pre-pressure Controller SCC-K NO2 / NO Converter CGO-9 Tubular Furnace Reaction Element Membrane Filter CGKW Condensate Monitor ER-144A/Ex Switching Unit Acid Filter Disposable Filter Flow Meters, Flow Monitors KFA Isolated Switch Amplifier Stripper for Cooling Water and Waste Water Multi-way Test Gas Cocks Cylinder Pressure Reducers Page 2 7 11 14 16 18 21 23 25 27 31 33 34 35 36 37 38 39 41 42 43 44 SCC-C Sample Gas Cooler ! Compressor sample gas cooler ! Constant outlet dew point ! 1 or 2 gas paths ! Heat exchanger made from glass, PVDF or stainless steel, exchangeable without tools ! Corrosion-resistant gas lines ! High pressure design up to 1 MPa (10 bar) ! Temperature display ! Suitable for ambient temperatures up to 50 °C ! Compact surface-mounting housing (width 1/2 19 inches, 6 height units) ! System solutions in connection with the SCC-F sample gas feed unit ! Suitable for use in measuring equipment conforming with 17th BImSchV (Federal Immission Protection Law) Pressure drop in heat exchanger approx. 1 hPa (1 mbar) approx. 4...8 hPa (4...8 mbar) for HE125 Sample gas inlet conditions Sample gas pressure Heat exchanger Sample gas pressure pabs material without with peristaltic pump peristaltic pump Glass PVDF Stainless steel 50...200 kPa (0.5...2.0 bar) 50...250 kPa (0.5...2.5 bar) 0.05...1 MPa (0.5...10 bar) 50...150 kPa (0.5...1.5 bar) 50...150 kPa (0.5...1.5 bar) 50...150 kPa (0.5...1.5 bar) Sample gas flow rate 1 x 250 l/h (HE250) or 1 x 125 l/h (HE125) or 2 x 125 l/h, with respect to the sample gas pressure pabs = 100 kPa (1 bar) and 25 °C Sample gas inlet temperature max. 140 °C Sample gas inlet dew point max. 70 °C, max. 60 °C for HE250 at sample gas flow rate > 200 l/h Dead volume in heat exchanger Heat exchanger material Glass PVDF Stainless steel Dead volume in heat exchanger HE125 HE250 40 ml 25 ml 30 ml 140 ml 100 ml 100 ml Gas tightness 5 x 10–6 hPa l/s Temperature display Digital display in °C Status signal < 0 °C and > 8 °C, 2 potential-free two-way switches, switching capacity 250 V AC, 2 A Refrigerant R 134a Materials of gas-conducting parts Operating data PVDF, PTFE, PP, glass, Viton, stainless steel (high pressure version) Sample gas outlet temperature Factory-set to +3 °C Dew point stability ±0.3 °C per 10 °C temperature change, ±0.3 °C per 10 l/h change in flow rate Refrigeration capacity 40 W at +10...+50 °C Warm-up time approx. 15 min 2 Power supply Input voltage 230 V AC or 115 V AC –15...+10 %, 50...60 Hz Power consumption max. 200 VA Starting current 2.5 A at 230 V AC System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 SCC-C Sample Gas Cooler Construction Electromagnetic compatibility Design Surface-mounting housing 1/2 19 inch, 6 height units Radio interference suppression Class B to EN 55011 Mounting On the wall with mounting brackets supplied or in a 19-inch cabinet / rack Interference immunity Testing to EN 50082-2 Housing material and color Sheet steel; light gray (RAL 7035), basalt gray (RAL 7012) Testing to EN 60068-2-27 and EN 60068-2-6 Degree of protection of housing IP 20 to EN 60529 Transport Shock: 30 g / 18 ms / 18 shocks Vibration: 1 g / ±0.15 mm / 5...150 Hz, 3 x 5 cycles Dimensions see dimensional drawing on page 4 Weight approx. 15.6 / 16.5 kg with 1/ 2 heat exchangers Heat exchanger Heat exchanger Sample gas inlets & material outlets Condensate outlet Glass Pipe nipple GL25 Stainless steel Screwed pipe or hose connection GL18 6 mm tube G 1/4 inch internal thread G 3/8 inch internal thread G 3/8 inch internal thread Peristaltic pump (option) Condensate outlet PVDF, DN 4/6 Electrical connections Power supply Cable, 3 m long, permanently fixed Status signal Cable, 3 m long, permanently fixed Electrical safety Ambient temperature Operation: +10...+50 °C, Storage and transport: –25...+60 °C Relative humidity ≤ 75 % annual average, occasional and slight condensation permitted, ≤ 95 % on 30 days per year Options Metering device in gas path 1 by means of a peristaltic pump installed in the SCC-C sample gas cooler or in the SCC-F sample gas feed unit, feed tank as accessory, for small SO2 measuring ranges (< 1000 mg/m3) or to avoid acid aerosols Peristaltic pumps 1 or 2 peristaltic pumps for discharging condensate (flow rate approx. 300 ml/h, 5 rpm) and metering (flow rate approx. 15 ml/h), Pressure resistance pabs = 50...150 kPa (0.5...1.5 bar), Peristaltic tube service life approx. 5 months, Power consumption 3.5 VA, Weight approx. 0.6 kg CSA certification Testing to EN 61010-1 Protective class I Overvoltage category / degree of contamination III / 2 Protective separation Electrical isolation of the 115 / 230 V AC power supply from the other current circuits by means of reinforced or double insulation. Functional extra-low voltages (PELV) on the low voltage side 10/23-5.20 EN January 2004 Operation Vibration: 1 g / ±0.07 mm / 5...55 Hz, 3 x 2 cycles Ambient conditions Gas connections PVDF Mechanical capabilities The SCC-C sample gas cooler is certified to – Class 2258 02 Process Control Equipment – For Hazardous Locations and – Class 2258 82 Process Control Equipment – For Hazardous Locations – Certified to U.S. Standards Class 1, Div. 2, Groups A, B, C and D, Temperature Code T4, Maximum Ambient Temperature +50 °C. Approval includes testing per applicable Canadian (CSA) and US directives. Certificate No. 1105720 System Components and Accessories for Sample Gas Conditioning 3 SCC-C Sample Gas Cooler Dimensional drawing (dimensions in mm) 13 1 2 1 3 4 190.5 266 3.0 Temperature display Condensate outlet (for option with peristaltic pumps) Gas connections of heat exchangers Conduits for the (permanentlyconnected) electrical connection lines 37.8 2 246 263 220 301.5 4 46 3 Circuit and connection diagram Bridge = 230V Transformer = 115V Mains L F1 X1/4 X2/2 L 2A T R2 U X2/3 275V L X4/3 X4/2 M ~ X5/O/5 M1 1 Pt 100 X4/1 Option Pt 100 X5/O/3 X2/1 T T R1 3 X4/4 C R S X5/O/2 5+ X6/4 X3/3 X5/M/2 Solid X3/1 6- C1 4,7µF A1 X6/3 X5/O/1 X5/U/2 X5/M/3 K1 Alarm Status 1 X3/2 8 X6/2 9 X6/1 X5/O/4 Fan M2 X3/6 N X3/4 MV1 K1 M ~ X5/O/6 X5/O/7 SR25 M4 SR25 M3 M ~ M ~ A2 K1 Status 2 X5/M/5 X5/M/1 X5/M/4 X5/M/7 X5/M/6 X3/5 Mains N X1/3 Mains PE X1/2 X5/U/1 X5/U/4 X5/U/3 X1/1 4 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 SCC-C Sample Gas Cooler Refrigerant circuit 1 2 3 4 5 6 7 8 1 2 Refrigerant compressor Refrigerant condenser Refrigerant dryer Capillary tube Heat exchanger Evaporator Cooling block with temperature sensor Valve 3 8 4 9 °C 7 5 6 10/23-5.20 EN January 2004 System Components and Accessories for Sample Gas Conditioning 5 SCC-C Sample Gas Cooler Ordering information Catalog No. 23070-0↓ Design Wall-mounted housing 1/2-19 Inch ↓ ↓ ↓ ↓ ↓ ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ ↓ 0 ↓ 0 ↓ 0 ↓ 0 1 Preparation without with dosing unit 0 1 Heat exchanger Glass PVDF Stainless steel 1 2 3 Gas paths 1 gas path 250 l/h 1 gas path 125 l/h 2 gas paths 2 x 125 l/h 1 2 3 Condensate drain without 1 peristaltic pump 2 peristaltic pumps (2 x condensate) 2 peristaltic pumps (1 x condensate, 1 x dosing) 2 peristaltic pumps (1 x condensate, 1 x precondensation) 0 1 2 3 4 Display Temperature display and monitoring Temperature display and monitoring and Pt 100 1 2 Power supply 230 V, 50/60 Hz 115 V, 50/60 Hz 1 2 Certification without with CSA certification 0 1 ↓ ↓ ↓ ↓ Catalog No. 23070-0- 6 ↓ System Components and Accessories for Sample Gas Conditioning ↓ ↓ ↓ ↓ 10/23-5.20 EN January 2004 SCC-F Sample Gas Feed Unit ! Complete sample gas conditioning in connection with the SCC-C sample gas cooler ! 2 independent gas paths ! Corrosion resistant, metal-free gas lines ! Compact surface-mounting housing (width 1/2 19 inches, 6 height units) ! Service-friendly due to easy access to the modules Sample gas inlet conditions Feed performance standard Sample gas pressure pabs = 70...105 kPa (0.7...1.05 bar) Flow rate / l/h -600 -400 h -2 Pa 00 hP a a hP 100 -1 00 -4 00 hP a -200 0 200 Pressure / hPa 400 600 800 A Inlet: negative pressure, outlet: atmospheric pressure B Inlet: acc. to chart, outlet: gauge pressure Operating data Warm-up time approx. 10 minutes (plus warm-up time of sample gas cooler) Feed performance bypass 350 300 Dead volume approx. 10 cm3 (plus dead volume of heat exchanger) Flow rate display and adjustment Rotameter 10...100 l/h with needle valve (metal-free) Status signals Flow rate and condensate monitors: 2 potential-free two-way switches, switching capacity 250 V AC, 2 A 250 Flow / l/h Gas tightness 5 x 10–6 hPa l/s 10/23-5.20 EN January 2004 150 50 -800 B 00 -3 Sample gas inlet dew point The dew point of the sample gas must be at least 5 °C lower than the lowest ambient temperature in the whole sample gas path. Otherwise a sample gas cooler or a condensate trap is required. 200 a hP Sample gas inlet temperature +10...+50 °C Inlet pressure 0 Sample gas flow rate Gas paths 1 and 2 max. 100 l/h Bypass max. 200 l/h 250 A 200 150 100 50 -1000 -500 0 500 Pressure / hPa System Components and Accessories for Sample Gas Conditioning 1000 1500 2000 2500 7 SCC-F Sample Gas Feed Unit Material of gas-conducting parts Electromagnetic compatibility PVDF, PTFE, PVC, EPDM, Viton, Novoprene Radio interference suppression Class B to EN 55011 Power supply Interference immunity Testing to EN 50082-2 Input voltage 230 V (207...250 V) AC, 50 Hz or 60 Hz ± 2 Hz 115 V (100...135 V) AC, 50 Hz or 60 Hz ± 2 Hz Mechanical capabilities Power consumption during operation Diaphragm pump approx. 50 VA, metering pump approx. 3.5 VA Testing to EN 60068-2-27 and EN 60068-2-6 Construction Operation Vibration: 1 g / ±0.07 mm / 5...55 Hz, 3 x 2 cycles Design Surface-mounting housing 1/2 19 inch, 6 height units Mounting On the wall with the mounting brackets supplied or in a 19 inch cabinet / rack Housing material and color Sheet steel; light gray (RAL 7035), basalt gray (RAL 7012) Degree of protection of housing IP 20 to EN 60529 Dimensions see dimensional drawing on page 9 Gas connections PVDF coupling for tube of 6 x 4 x 1 mm Electrical connections Power supply Screw clamp terminals for stranded or solid wire with max. 1.5 mm2 Status signals Screw clamp terminals for stranded or solid wire with max. 1.5 mm2 Electrical safety Transport Shock: 30 g / 18 ms / 18 shocks Vibration: 1 g / ±0.15 mm / 5...150 Hz, 3 x 5 cycles Ambient conditions Ambient temperature Operation: +10...+50 °C, Storage and transport: –25...+60 °C Relative humidity ≤ 75 % annual average, occasional and slight condensation permitted, ≤ 90 % on 30 days/year Options Metering unit By means of peristaltic pump, flow rate 15 ml/h, feed tank as accessory for small SO2 measuring ranges (< 1000 mg/m3) or to avoid acid aerosols I/O card To connect the SCC-F sample gas feed unit and the SCC-C sample gas cooler to the AO2000 Series continuous gas analyzers via the system bus – Display and monitoring of the cooler temperature – Monitoring and processing of status signals of the SCC-F sample gas feed unit (condensate, flow rate) – Control of an external solenoid valve for zero gas connection, 230 V, 50 Hz – Digital inputs for monitoring condensate collecting bottles and reagent reservoirs Testing to EN 61010-1 CSA certification Protective class I Overvoltage category / degree of contamination III / 2 Protective separation Electrical isolation of the 115 / 230 V AC power supply from the other current circuits by means of reinforced or double insulation. Functional extra-low voltages (PELV) on the low voltage side The SCC-F sample gas feed unit is certified to – Class 2258 02 Process Control Equipment – For Hazardous Locations and – Class 2258 82 Process Control Equipment – For Hazardous Locations – Certified to U.S. Standards Class 1, Div. 2, Groups A, B, C and D, Temperature Code T4, Maximum Ambient Temperature +50 °C. Approval includes testing per applicable Canadian (CSA) and US directives. Certificate No. 1105720 8 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 SCC-F Sample Gas Feed Unit Dimensional drawing (dimensions in mm) Z Ansicht / View Z 20 220 2 6 7 4 37.8 Sample gas inlet Sample gas outlet Electrical connections Flow rate monitor with needle valve Metering pump Condensate monitor LED display and reset button of switching amplifiers 301.5 266 190.5 6 1 1 2 3 4 5 6 7 4 5 246 46 263 Ordering information Catalog No. 23212-0↓ Design Wall-mounted housing 1/2-19 Inch ↓ ↓ ↓ ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 1 Gas paths 1 gas path, 1 condensate monitor, 1 flow monitor, 1 diaphragm pump 2 separate gas paths, 2 condensate monitors, 2 flow monitors, 2 diaphragm pumps 1 gas path, 1 condensate monitor, 2 flow monitors, 1 diaphragm pump 1 gas path, 1 condens. monitor, 2 flow monitors, 1 diaphr. pump, 1 pressure controller 2 separate gas paths, 2 condensate monitors, 2 flow monitors, 1 diaphragm pump 2 separate gas paths, 2 condensate monitors, 1 flow monitor, 1 diaphragm pump 1 2 3 4 5 6 Dosing without with dosing pump 0 1 Electronic processing unit with 1 electronic processing unit with 2 electronic processing units with I/O interface board 1 2 3 Power supply 230 V, 50/60 Hz 115 V, 50/60 Hz 1 2 Certification without with CSA certification 0 1 ↓ ↓ ↓ ↓ Catalog No. 23212-0- 10/23-5.20 EN January 2004 ↓ System Components and Accessories for Sample Gas Conditioning ↓ ↓ 9 SCC-F Sample Gas Feed Unit Pneumatic diagrams Catalog number 23212-0-11XXXX000000 Catalog number 23212-0-12XXXX000000 Catalog number 23212-0-13XXXX000000 Catalog number 23212-0-14XXXX000000 Catalog number 23212-0-15XXXX000000 Catalog number 23212-0-16XXXX000000 10 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 SCC-E Sample Gas Feed Unit ! Process-proven modules ! Ideal for processes with non-corrosive gases ! Integrated Peltier cooler and peristaltic pump (option) ! Simple installation und connection ! Portable housing for rack and wall mounting (1/2 19 inch, 4 height units) ! Attractively priced system solution with EL1020 gas analyzer Sample gas inlet conditions Power supply Sample gas pressure pabs = 70...105 kPa (0.7...1.05 bar) Input voltage 230 V AC, 50 Hz or 115 V AC, 60 Hz Sample gas flow rate 7...70 l/h Power consumption during operation 230 V AC, 50 Hz: 1.05 A, 240 VA Sample gas inlet temperature +10...+50 °C Construction Sample gas inlet dew point (Peltier cooler) max. 50 °C Operating data Outlet dew point (Peltier cooler) +3 °C Warm-up time approx. 10 minutes with Peltier cooler Gas tightness 5 x 10–6 hPa l/s Flow rate display and adjustment Rotameter 10...100 l/h with needle valve (metal-free) Status signals Cooler, flow and condensate monitoring: 1 potential-free two-way switch, switching capacity 250 V AC, 2 A Design Surface-mounting housing 1/2 19 inch, 4 height units Mounting On the wall or in a 19 inch cabinet / rack with the mounting brackets supplied Housing material and color Sheet steel; light gray (RAL 7035), basalt gray (RAL 7012) Degree of protection of housing IP 20 to EN 60529 Dimensions see dimensional drawing on page 13 Weight approx. 11.2 kg Gas connections PPH couplings for tube 6 x 4 x 1 mm Material of gas-conducting parts PPH, EPDM, Viton, Novoprene, glass Electrical connections Power supply Cable, length 1.5 m, permanently fixed Status signal Cable, length 1.5 m, permanently fixed 10/23-5.20 EN January 2004 System Components and Accessories for Sample Gas Conditioning 11 SCC-E Sample Gas Feed Unit Electrical safety Pneumatic diagrams Testing to EN 61010-1 Version without cooler Protective class I 2 3 Overvoltage category / degree of contamination III / 2 Protective separation Electrical isolation of the 115 / 230 V AC power supply from the other current circuits by means of reinforced or double insulation. Functional extra-low voltages (PELV) on the low voltage side 1 Electromagnetic compatibility Radio interference suppression Class B to EN 55011 Version with Peltier cooler and condensate pump Interference immunity Testing to EN 50082-2 2 3 Mechanical capabilities Testing to EN 60068-2-27 and EN 60068-2-6 1 Transport Shock: 30 g / 18 ms / 18 shocks Vibration: 1 g / ±0.15 mm / 5...150 Hz, 3 x 5 cycles 4 Operation Vibration: 1 g / ±0.07 mm / 5...55 Hz, 3 x 2 cycles Ambient conditions Ambient temperature Operation: +10...+45 °C, Storage and transport: –25...+60 °C 1 2 3 4 Sample gas inlet Test gas inlet Sample gas outlet Condensate outlet Relative humidity ≤ 75 % annual average, occasional and slight condensation permitted, ≤ 90 % on 30 days/year 12 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 SCC-E Sample Gas Feed Unit Dimensional drawing (dimensions in mm) 10 7 263 220 3.0 10 Alarm Pump 5 6 7 101,5 9 177 8 Sample Gas Test Gas SCC-E 37,75 11 246 1) only in version with Peltier cooler and condensate pump 12 185 220 Sample gas inlet Test gas inlet Sample gas outlet Power supply and status signal cables Flow rate monitor with needle valve Peristaltic pump 1) Condensate monitor 1) / diaphragm filter LED indicator condensate alarm red 1) Pump switch Temperature controller for cooler 1) 3-way cock sample gas / test gas Condensate outlet 1) 4 x M5 threaded holes in ground plate 47,5 300 372,5 1 2 4 3 17,5 1 2 3 4 5 6 7 8 9 10 11 12 13 25 13 248 36 Ordering information Catalog No. 23235-0↓ ↓ ↓ with 3-way cock, diaphragm filter, pump and flow monitor with needle valve with 3-way cock, condensate monitor, pump and flow monitor with needle valve 1 2 0 1 Cooler and condensate pump without with Peltier cooler and condensate pump 1 2 0 1 Design Wall-mounted housing 1/2-19 inch ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 1 2 ↓ ↓ ↓ ↓ Catalog No. 23235-0- 10/23-5.20 EN January 2004 0 ↓ 1 Power supply 230 V, 50 Hz 115 V, 60 Hz Accessories Carry handle 0 ↓ Catalog No. 23009-4-0730702 System Components and Accessories for Sample Gas Conditioning 13 Electrical Cool Trap ■ Sample gas cooling with Peltier element ■ Heat exchanger made of PVDF ■ Status signals for too high or too low temperature ■ Automatic condensate drain as an option Sample gas inlet conditions Construction Sample gas pressure pabs = 40...220 kPa (0.4...2.2 bar) at sample gas inlet temperature 150 °C Design Surface-mounting housing (1/2 19-inch) for wall mounting Sample gas flow rate 150 l/h related to 100 kPa (1 bar) and 25 °C at sample gas inlet temperature 150 °C Sample gas inlet dew point ≤ 65 °C Housing material Aluminum sheet, anodized without color Degree of protection of housing IP 20 to EN 60529 Dimensions see dimensional drawing on page 15 Operating data Weight approx. 7 kg Sample gas outlet temperature +10 °C Gas connections Refrigeration capacity > 54 kJ at ambient temperature 25 °C Timer for the automatic condensate drain Run time 2 min, off period 20 min Dead volume of the heat exchanger approx. 50 ml Sample gas Pipe, 6 x 1 mm Condensate drain Pipe, 12 x 1 mm in version with peristaltic pump: hose 6 x 1 mm Electrical connections Buffer volume for condensate approx. 10 ml Power supply Cable with grounding plug, length 5 m Materials of gas-conducting parts PVDF, FEP Status signal (optional) Sub-miniature socket, 9-pin, with plug and cable, length 5 m Power supply Input voltage 230 V AC –13...+5 %, 50 Hz 115 V AC –13...+5 %, 50 Hz or 60 Hz with integral peristaltic pump only 50 Hz; 60 Hz on request Power consumption approx. 70 VA 14 Mechanical capabilities Testing to EN 60068-2-27 and EN 60068-2-6 Transport Shock: 30 g / 18 ms / 18 shocks Vibration: 2 g / ±0.15 mm / 5...150 Hz, 3 x 5 cycles Operation Vibration: 1 g / ±0.07 mm / 5...55 Hz, 3 x 2 cycles System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 Electrical Cool Trap Ambient conditions Dimensional drawing (dimensions in mm) Ambient temperature Operation: +5...+35 °C Storage and transport: –25...+60 °C 320 42 70 Relative humidity ≤ 75 % annual average, slight and occasional condensation permissible Climatic class 3K4 to EN 60721-3-3 Ordering information 230 190 21 ø8.5 10 300 208 Catalog No. Electrical cool trap, 230 V, 50 Hz 23058-5-8018055 Electrical cool trap with automatic condensate drain, 230 V, 50 Hz 23058-5-8018054 Electrical cool trap, 115 V, 60 Hz 23058-5-8018463 Electrical cool trap with automatic condensate drain, 115 V, 60 Hz 23058-5-8018462 Circuit and connection diagram 10/23-5.20 EN January 2004 System Components and Accessories for Sample Gas Conditioning 15 CGKA 2 Automatic Condensate Drain ■ For connection to any sample gas cooler ■ Version with level contact as an option ■ Time relay available as an accessory Condensate inlet conditions Power supply Inlet pressure pabs = 50...150 kPa (0.5...1.5 bar) with unpressurized outlet Input voltage 220 V AC –15...+10 %, 50 Hz, or –5...+10 %, 60 Hz 110 V AC –10...+10 %, 50 Hz or 60 Hz Condensate temperature +1...+70 °C Power consumption 7 VA Viscosity of the condensate approx. 50...175 Pa s Construction Operating data Outlet pressure pabs = 50...150 kPa (0.5...1.5 bar) with unpressurized inlet Delivery 1 l/h ± 10 %, max. 0.4 l/h at 40 % cyclic duration factor Buffer volume 0.2 l Design Surface-mounting housing for wall mounting Housing material and color Polycarbonate, RAL 7032 Degree of protection of housing Motor housing: IP 54, wheel head with plastic top: IP 20 to EN 60529 Dimensions see dimensional drawing on page 17 Rotational speed of pump 20 RPM at 50 Hz Gas tightness pabs = 50...150 kPa (0.5...1.5 bar) from the pressure to the suction side in every wheel head position Weight approx. 1.7 kg Service life of hose Replace hose as a preventive measure every six months Gas connections Materials of gas-conducting parts Condensate drain Bulkhead screwed connection DN 4/6 for hose 6 ∅ 1 mm Verderprene, PP, PVC, Norprene, LLDPE Condensate inlet Connecting branches for hose 15.9 ∅ 3.2 mm Electrical connections Terminals for stranded or solid wire with max. 1.5 mm2, feed-through via membrane nipple PG 9 16 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 CGKA 2 Automatic Condensate Drain Mechanical capabilities Dimensional drawing (dimensions in mm) Testing to EN 60068-2-27 and EN 60068-2-6 Transport Shock: 30 g / 11 ms / 18 shocks Vibration: 2 g / ±0.17 mm / 5...150 Hz, 3 x 5 cycles Operation Vibration: 0.5 g / ±0.04 mm / 5...55 Hz, 3 x 2 cycles Ambient conditions Ambient temperature Operation: +5...+50 °C intermittent mode with cyclic duration factor ≤ 40 %, i.e. run time max. 5 minutes and off period approx. 7.5 minutes Storage and transport: –25...+60 °C Relative humidity ≤ 75 % annual average, occasional and slight condensation permissible Climatic class 3K4 to EN 60721-3-3 Level contact (optional) 1 2 3 4 5 6 Condensate inlet Condensate outlet Pump inlet Power supply Mounting holes Outer link “Overflow” status signal Floating contact, rating 24 V / 1 A Ordering information Accessories for condensate disposal CGKA 2 220 V, 50 Hz 23227-5-8018441 Time relay CGKA 2 220 V, 60 Hz 23227-5-8018442 Run time and off period settings 0.6...60 sec., recommended setting: cyclic duration factor 40 %, i.e. run time 5 minutes and off period 7.5 minutes CGKA 2 110 V, 50 Hz 23227-5-8018446 CGKA 2 115 V, 60 Hz 23227-5-8018443 CGKA 2 with level monitor 220 V, 50 Hz 23227-5-8018445 Degree of protection Terminals IP 20, housing IP 50 to EN 60529 CGKA 2 with level monitor 220 V, 60 Hz 23227-5-8018444 Weight approx. 0.125 kg CGKA 2 with level monitor 110 V, 50 Hz 23227-5-8018448 CGKA 2 with level monitor 115 V, 60 Hz 23227-5-8018447 Catalog No. Power supply 12...240 V AC/DC, 40...440 Hz Accessories Timer relay 90805-4-0741607 Reagent and condensate bottle 23234-5-8328972 Sample gas pressure pabs = 70...150 kPa (0.7...1.5 bar) Level monitor condensate 23005-4-0741239 Material LDPE / PVC Level monitor reagent Condensate collecting bottle Volume 10 l Connections Sample gas: 1 connecting piece for hose with ID 4–5 mm Condensate: 2 connecting pieces for hose with ID 12–13 mm Condensate drain: SW 22 Condensate trap, filter surface 20 cm 90805-5-8308994 2 23065-5-8018512 Weight approx. 1 kg Level monitor Switching voltage 30 V Switching current 1 A Switching power 30 VA Connecting cable 2 x 0.25 mm2, length 5 m 10/23-5.20 EN January 2004 System Components and Accessories for Sample Gas Conditioning 17 CGMF 2 Sample Gas Feed Unit ! Feeding-in the sample gas ! Micro-porous filtration of the sample gas ! Monitoring of the sample-gas path for condensate breakthrough with fault status signaling ! Adjustment and monitoring the sample gas flow rate with alarm value signaling ! Compact unit with degree of protection of housing IP 20 Operating data Structure Inlet pressure pabs = 70...105 kPa (0.7...1.5 bar) Sample gas feed-in Diaphragm pump 4N (see page 21) Flow rate max. 250 l/h at atmospheric pressure Micro-porous filtration Diaphragm filter in PVC Inlet temperature +5...+50 °C Condensate monitoring Diaphragm filter in PVC, monitoring of the diaphragm filter for moisture by means of electrodes (conductivity measurement); fault status signaling with separate amplifier relay ER 144A/Ex (see page 36) Inlet dew point below room temperature Delivery see delivery diagram of the diaphragm pump 4N on page 21 Flow meter Flow rate 7...70 l/h, Bypass 25...250 l/h Diaphragm filter Retention rate 100 % for particles > 1 µm Tightness Pressure drop 0.1 hPa/min Flow rate monitoring Hovering body flow meter with inductive sensor for alarm value monitoring and needle valve; alarm value signaling with separate switching unit KFA (see page 41) Construction Design Surface-mounting case, motor axis horizontal Materials of the parts in contact with medium Housing material and color Plastic, RAL 7035 ETFE (ethylene-tetrafluorethylene), PP (polypropylene), FPM (Viton), PVC (polyvinyl chloride), EPDM (ethylene-propylene), special steel Degree of protection of housing IP 20 to EN 60529 Power supply Dimensions see dimensional drawing on page 19 AC voltage supply 230 V ± 10 %, 50 Hz or 60 Hz 115 V ± 10 %, 50 Hz or 60 Hz Power consumption approx. 50 VA Class of protection I Weight approx. 2.3 kg Gas connections G 1/4 female thread (DIN ISO 228/1) for male fittings, nozzles for hose internal diameter 4 mm are supplied with the unit 18 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 CGMF 2 Sample Gas Feed Unit Electrical connections Ambient conditions Terminals via cable connection PG 13.5 Ambient temperature Operation: +5...+50 °C Storage and transport: –25...+65 °C Mechanical capabilities Testing to DIN EN 60068-2-27 and DIN EN 60068-2-6 Transport Shock 30 g / 18 ms / 18 shocks Vibration: 2 g / ±0.15 mm / 5...150 Hz, 3 x 5 cycles Climatic class 3K4 to EN 60721-3-3 Operation Vibration: 2 g / ±0.07 mm / 4...7 Hz, 3 x 2 cycles Dimensional drawing (dimensions in mm) Electrical connection diagram ~165 45 11 Relative humidity ≤ 75 % annual mean, infrequent and light condensation permitted Z 3 32 17 60 32 95 140 Z Switching Unit ER 144A BN + BU - Switching Unit KFA.-SR2-Ex1.W ~150 2 1 3 29 RD WH + 16 148 160 6 L1 N ~150 88 120 Ø 4,2 1 Gas connections 2 Electrical connections 3 Needle valve U = 115 / 230 V AC L1 N PE Z-15193 Z-15199 Ordering information Catalog No. 23229-0↓ Degree of protection IP 20 (ambient temperature max. +50 °C) ↓ ↓ ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 ↓ 0 2 Gas outlets 1 sample gas outlet 1 sample gas outlet + 1 bypass outlet 1 2 Flow monitoring without with (switching unit KFA required, see page 41) 0 1 Condensate monitoring without with (switching unit ER 144A/Ex required, see page 36) 0 1 Power supply 230 V, 50/60 Hz 115 V, 50/60 Hz 1 2 ↓ ↓ ↓ ↓ Catalog No. 23229-0- 10/23-5.20 EN January 2004 ↓ System Components and Accessories for Sample Gas Conditioning ↓ 19 CGMF 2 Sample Gas Feed Unit Pneumatic diagrams Catalog number 23229-0-2100X0000000 Catalog number 23229-0-2101X0000000 Catalog number 23229-0-2110X0000000 Catalog number 23229-0-2111X0000000 Catalog number 23229-0-2200X0000000 Catalog number 23229-0-2201X0000000 Catalog number 23229-0-2210X0000000 Catalog number 23229-0-2211X0000000 20 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 Diaphragm Pump 4N ! Feed in of the sample gas ! Compact unit with degree of protection of housing IP 20 or IP 54 Operating data Materials of the parts in contact with medium Inlet pressure pabs = 70...105 kPa (0.7...1.5 bar) Valve plate, diaphragm: EPDM (ethylene-propylene); pump body: PP (polypropylene); hose: FPM (Viton); nozzles: ETFE (ethylene-tetrafluorethylene) Flow rate max. 250 l/h at atmospheric pressure Power supply Inlet temperature +5...+50 °C AC voltage 230 V ± 10 %, 50 Hz or 60 Hz 115 V ± 10 %, 50 Hz or 60 Hz Inlet dew point below room temperature Feed performance Power consumption approx. 50 VA 250 Flow rate / l/h 100 -400 Construction a a a hP hP hP 00 200 300 -1 - 150 -600 B a hP 200 50 -800 Inlet pressure 0 A -4 00 Design Surface-mounting case for wall attachment, motor axis horizontal Housing material and color Plastic, RAL 7035 hP a -200 0 200 Pressure / hPa 400 600 800 A Inlet: negative pressure, outlet: atmospheric pressure B Inlet: according diagram, outlet: negative pressure Tightness Pressure drop 0.1 hPa/min Degree of protection of housing IP 20 or IP 54 to EN 60529 Class of protection I Dimensions see dimensional drawing on page 22 Weight approx. 1.8 kg Gas connections G 1/4 female thread (DIN ISO 228/1) for male fittings, nozzles for hose inside diameter 4 mm are supplied with the unit. 10/23-5.20 EN January 2004 System Components and Accessories for Sample Gas Conditioning 21 Diaphragm Pump 4N Electrical connections Dimensional drawing (dimensions in mm) Terminals via cable connection PG 13.5 Mechanical capabilities Z Testing to DIN EN 60068-2-27 and DIN EN 60068-2-6 Transport Shock: 30 g / 18 ms / 18 shocks Vibration: 2 g / ±0.15 mm / 5...150 Hz, 3 x 5 cycles Operation Vibration: 2 g / ±0.07 mm / 4...7 Hz, 3 x 2 cycles 2 1 17 60 32 32 95 140 Z 88 120 16 Ambient temperature Operation: IP 54 +5...+40 °C, IP 20 +5...+50 °C Storage and transport: –25...+65 °C Relative humidity ≤ 90 % annual average, condensation permitted Climatic class 3K4 to EN 60721-3-3 ~150 ø 4,2 Ambient conditions 148 160 6 1 Gas connections 2 Electrical connections Z-14185 Ordering information Catalog No. Diaphragm Pump 4N, IP 20; 230V, 50/60 Hz 23134-5-8018545 Diaphragm Pump 4N, IP 20; 115V, 50/60 Hz 23134-5-8018546 Diaphragm Pump 4N, IP 54; 230V, 50/60 Hz 23134-5-8018547 Diaphragm Pump 4N, IP 54; 115V, 50/60 Hz 23134-5-8018548 22 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 Diaphragm Pump 2 ! Extremely robust version thanks to cast metal cladding ! Very reliable operationally and easy to maintain thanks to the simple method of operation ! Delivery adjustable using magnetic shunt Operating data Power supply Delivery max. 300 l/h at atmospheric pressure, under other pressure conditions: see delivery diagram. The diaphragm is moved by an electric magnet. The rate of flow can be changed by using a magnetic shunt. Power supply 220 V AC, 50 Hz 300 l/h Construction A I I B 200 II II 150 100 Z-2777 50 -0+ 50 Atmospheric pressure 100 hPa 150 p Diaphragm pump 2 Diaphragm pump 2-Ex (not available) Inlet: negative pressure, outlet: atmospheric pressure Inlet: atmospheric pressure, outlet: negative pressure Time-related behavior Flow rate 30 l/h 60 l/h 90 l/h Dead time 0.9 s 0.7 s 0.6 s Time constant 1.1 s 1.0 s 0.9 s Design Surface-mounting case for wall attachment Housing material Cap and lower part in light alloy casting 100 I II A B Power consumption max. 13 VA, depending on adjustment of the delivery Pressure drop 0.4 hPa 1.1 hPa 1.8 hPa Degree of protection of housing IP 54 to EN 60529 Weight approx. 3 kg Gas connections G 1/4 female thread (DIN ISO 228/1) for male fittings, nozzles for hose inside diameters 4 mm are supplied with the unit Electrical connections Terminals via cable connection PG 11 Materials of the parts in contact with medium Ambient conditions Diaphragm: EPDM; valves: FPM (Viton); pump body: PVDF; hose: PVC; nozzles: PTFE (Hostaflon) Ambient temperature Operation: +5...+45 °C, storage and transport: –25...+65 °C Relative humidity ≤ 90 % annual average, condensation permitted Climatic class 3K4 to EN 60721-3-3 10/23-5.20 EN January 2004 System Components and Accessories for Sample Gas Conditioning 23 Diaphragm Pump 2 Ordering information Dimensional drawing (dimensions in mm) Catalog No. Diaphragm Pump 2, 220 V, 50 Hz 23121-5-5861212 ~170 2 50 1 PG 11 65 160 192 ~90 Z-20374 24 O 8,4 1 Sample gas connections 2 Gate valve for regulating the feed quantity System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 Pre-pressure Controller ! Keeps the sample gas pressure constant irrespective of flow resistances such as filter blockage and long samplegas lines ! Prevents jumps in pressure in the sample gas feed-in system, so that the pump service life is increased ! Use as a bypass controller with a sample gas flow rate of 60 l/h (normal case) ! Use as flow-off controller, where short dead times must be achieved Operating data Construction Inlet pressure pabs = 750...1000 hPa (mbar) Mounting Wall mounting with support bracket (supplied), vertical or horizontal Inlet temperature +5...+70 °C Housing material Brass, nickel plated Flow rate (outflow volume or bypass) 50...250 l/h with an adjusted outlet pressure of 100 hPa (mbar) Dimensions see dimensional drawing on page 26 Outlet pressure 80...120 hPa (mbar) positive pressure, adjustable Weight 0.68 kg Leak rate ≤ 10–4 mbar l/s Gas connections G 1/8 female thread (DIN ISO 228/1) for male fittings, nozzles for hose internal diameter 4 mm are supplied with the unit 120 l/h 100 Q = 120 l/h Mechanical capabilities Testing to DIN EN 60068-2-27 and DIN EN 60068-2-6 Transport Shock: 30 g / 11 ms / 18 shocks Vibration: 2 g / ±0.15 mm / 5...150 Hz, 3 x 5 cycles 80 Q = 60 l/h 60 40 Z-20077 Sample gas flow rate Q Flow rate characteristic of a bypass controller 750 800 850 900 950 hPa 1000 Pump inlet pressure pabs Materials of the parts in contact with medium PVDF, PTFE glass-fiber reinforced, Viton 10/23-5.20 EN January 2004 Operation Vibration: 1 g / ±0.07 mm / 5...55 Hz, 3 x 2 cycles Ambient conditions Ambient temperature Operation: +5...+70 °C, Storage and transport: –25...+70 °C Relative humidity ≤ 90 % annual average, condensation permitted System Components and Accessories for Sample Gas Conditioning 25 Pre-pressure Controller Dimensional drawing (dimensions in mm) Use options 50 40 0 ø4 17 27 Bypass controller Q1 G 1/8 5 ø40 40 65 ø6 14 ø9 30 max. 115 5 Q2 MG PG 1 PG 2 PG 3 Z-20075/1 M5 PG 4 Flow-off controller Q1 50 Ordering information Catalog No. Pre-pressure Controller 26 MG PG 1 PG 2 PG 3 PG 4 Q2 Z-20075/2 Z-20076 23034-4-0801710 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 SCC-K NO2 /NO Converter ! Catalytic converter based on carbon-molybdenum ! High catalyst service life ! Catalyst cartridge can be changed without tools ! Option: Version with heated sample gas inlet Operating data Construction Sample gas flow rate max. 150 l/h Design 19 inch slide-in housing, 3 height units Temperature range depending on sample gas flow rate: 30 l/h: 320 °C; 60 l/h: 320 °C; 90 l/h: 340 °C, 150 l/h: 360 °C Mounting In 19 inch cabinet / rack or with mounting brackets (accessories) on the wall, distance above min. 1 height unit Effectivity ≥ 95 % with new catalyst Housing material and color Sheet steel; light gray (RAL 7035), basalt gray (RAL 7012) Sample gas pressure pabs ≤ 200 kPa (2 bar) Degree of protection of housing IP 20 to EN 60529 Pressure drop ≤ 0.01 kPa (10 mbar) at 90 l/h Dimensions see dimensional drawing on page 29 Warm-up time approx. 30 min Weight approx. 8...9 kg 90% time T90 ≤ 10 s at 60 l/h Gas connections Status signal for temperature deviation 1 NO potential-free contact, capacity 24 V DC, 1 A Materials of gas-conducting parts Sample gas inlet and outlet unheated G 1/4 female thread to DIN ISO 228/1 Heated sample gas inlet Swagelok® screwed connection for pipes with 6 mm outer diameter Stainless steel W-No. 1.4571, PVDF, PTFE, Viton Electrical connections Power supply Input voltage 230 V AC or 115 V AC –15...+10 %, 48...62 Hz Power consumption 230 V AC: 350 VA; 115 V AC: max. 170 VA 10/23-5.20 EN January 2004 Power supply Connector for non-heating apparatus, cable with grounding plug, length 2 m Status signal 9 pin Sub-D female connector with counter-plug System Components and Accessories for Sample Gas Conditioning 27 SCC-K NO2 /NO Converter Electrical safety Service life of catalyst Testing to EN 61010-1 The service life of the catalyst depends on its operating temperature as well as the flow rate and the NO2 and O2 content of the sample gas. It can be estimated with the help of the charts below. Protective class I Protective separation Electrical isolation of the 115 / 230 V AC power supply from the other current circuits by means of reinforced or double insulation. Functional extra-low voltages (PELV) on the low voltage side Service life / days Overvoltage category / degree of contamination III / 2 700 600 500 400 300 200 100 0 Electromagnetic compatibility 30 l/h 60 l/h 90 l/h 5 Radio interference immunity Class B to EN 55011 10 15 20 25 30 35 40 45 50 NO2 / ppm 5 Vol.-% O2 Service life / days Interference immunity Testing to EN 50082-2 Ambient conditions Ambient temperature Operation: +10...+50 °C, Storage and transport: –25...+65 °C Relative humidity ≤ 75 % annual mean, occasional and slight condensation permitted 450 400 350 300 250 200 150 100 50 0 30 l/h 60 l/h 90 l/h 5 10 15 20 25 30 35 40 45 50 NO2 / ppm 10 Vol.-% O2 The SCC-K NO2 / NO converter is certified to – Class 2258 01 Process Control Equipment and – Class 2258 81 Process Control Equipment – Certified to U.S. Standards Approval includes testing per applicable Canadian (CSA) and US directives. Certificate No. 1105720 Service life / days CSA certification 250 200 30 l/h 60 l/h 150 100 90 l/h 50 0 5 10 15 20 25 30 35 40 45 50 NO2 / ppm Ordering information 21 Vol.-% O2 Catalog No. Converter SCC-K, cock PVDF, 230 VAC 23093-4-0801974 Converter SCC-K, 2 solen. valves, 230 VAC 23093-4-0801975 Converter SCC-K, heated, 1 s.v., 230 VAC 23093-4-0801976 Converter SCC-K, cock PVDF, 115 VAC 23093-4-0801977 Converter SCC-K, 2 solen. valves, 115 VAC 23093-4-0801978 Converter SCC-K, heated, 1 s.v., 115 VAC 23093-4-0801979 Accessories Wall mounting bracket 23009-4-0801980 Carbon catalyst set 23009-4-0801981 28 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 SCC-K NO2 /NO Converter Dimensional drawing (Dimensions in mm) 483 2 325 132,5 (3HE) 260 44 3 4 5 400 400 NO NOx 1 Power supply input X1 Status signal output X2 (9-pin Sub-D female connector) Heated sample gas inlet 6 mm Sample gas outlet G1/4 inch Sample gas inlet G1/4 inch Ansicht von hinten 465.6 57 120 435 1 2 3 5 4 Circuit and connection diagram Bei Steuerung nur intern Brücke X2/1 nach X2/6 Internal controlled only link X2/1 to X2/6 Converter Statussignal NO Status signal NO X1 F1/2 3,15A internal external X2/5 X2/9 X2/1 X8/4 X8/6 X8/10 X3/2 X2/3 X2/6 X8/1 X8/8 X9/3 X9/1 X9/4 A1 ASP 204M K1 PE X2/2 X8/9 Netzfilter mains suppression filter X3/3 Netz Power supply Bypass K2 K3 S1 X3/1 X4/3 X5/4 X5/3 X5/2 X5/5 X5/6 F4 Y1 Y2 + - E1 X6/2 X6/1 L1 83 80 142 111 143 112 E1.1 243 X6/5 242 X6/4 X4/2 230V 81 115V X6/6 N D1 1N4007 T1 115V X6/3 D2 1N4007 F3 Frontplatte front panel + C1 D3 470µF 35V K1 X9/6 D4 X9/5 K2 X5/1 X7/1 0 sw./bl. X7/2 + rot/red M1 10/23-5.20 EN January 2004 System Components and Accessories for Sample Gas Conditioning 29 SCC-K NO2 /NO Converter Pneumatic layouts Standard version with 4-way ball valve 1 Power supply 2 Status signal 4 Sample gas outlet 5 Sample gas inlet E1 Tube furnace Y1 4-way ball valve 4 360 2 E1 1 Y1 5 Option with heated sample gas inlet 1 Power supply 2 Status signal 3 Heated sample gas inlet 4 Sample gas outlet E1 Tube furnace Y1 3/2-way solenoid valve 3 360 2 E1 1 Y1 4 4 360 2 Option with two solenoid valves 1 Power supply 2 Status signal 4 Sample gas outlet 5 Sample gas inlet E1 Tube furnace Y1 3/2-way solenoid valve Y2 3/2-way solenoid valve E1 Y2 1 Y1 5 30 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 CGO-9 Tubular Furnace Application and description The tubular furnace is used to convert a non-measurable gas component into a measurable compound which can be measured by a gas analyzer. This is for example necessary with certain carbon, sulfur and halogen (such as chlorine) compounds. The conversion is performed in a reaction tube which is filled with a catalyst and heated by the tubular furnace. A further application of the tubular furnace is to remove interfering components without the other gas components being affected. Technical data Sample gas pressure pabs ≤ 120 kPa (1.2 bar) Operating data Dead time in s at 30 l/h 60 l/h Without filling 1.5 0.5 With filling 2 0.7 90% time Pressure drop in s at in hPa/mbar at 30 l/h 60 l/h 30 l/h 60 l/h 2 0.75 1.5 3.6 4.5 2.5 6 12 Dimensional drawing (dimensions in mm) Reaction tube Material quartz, volume 20 ml, filling volume 8 ml Thermocouple Chromel-Alumel (corresponds to NiCr-Ni) Furnace temperature max. 800 °C The intermediate temperatures are set using an external on/off controller. Heat-up time approx. 120 min. Power supply AC voltage 220 V +10...–12 %, 48...62 Hz Power consumption 150 W Case material Steel sheet Degree of protection of housing IP 50 to EN 60529 A protective cap (accessory) is required if the tubular furnace is not protected against touching by design measures such as installation in a cabinet or a case. Weight approx. 1.0 kg 4 Terminal box 5 Thermocouple 6 Protective cap Ordering information Mounting Wall fastening Catalog No. Sample gas connection Glass tube 5 mm outside diameter for hose with 4 mm inside diameter Electrical connections Terminals via cable gland PG 9 Ambient temperature Operation: +5...+50 °C, Storage and transport: –25...+65 °C 10/23-5.20 EN January 2004 1 Gas inlet 2 Gas outlet (offset by 60°) 3 Mounting bracket or strap CGO-9 with reaction tube, with thermocouple 23092-4-0806560 CGO-9 with reaction tube, with catalyst LF 316, with thermocouple 23092-4-0856545 Accessories CGO-9 reaction tube, quartz 23005-4-0806559 CGO-9 reaction tube, stainless steel with catalyst LF 316 23004-4-0856544 CGO-9 stainless steel catalyst LF 316 23004-4-0801715 System Components and Accessories for Sample Gas Conditioning 31 CGO-9 Tubular Furnace Examples of applications Application Furnace Temperature Reagent temperature controller Sample gas Mounting throughput Oxidation of sulfur compounds Combustion of organic chlorine compounds Conversion of H2 to HCl using Cl2, where Cl2 concentration ≥ H2 concentration (O2 concentration > 4 Vol.-%, otherwise use reaction element, see page 33) NO2/NO conversion in the exhaust air of nitric acid or pickling plants Combustion of NH3 in air Combustion of organic nitrogen compounds, such as emissions from animal keeping or carcass incineration Application range: 100...3000 ppm NO2 800 °C 800 °C 800 °C no yes yes none none none 60 l/h 60 l/h 60 l/h 750 °C yes Stainless steel catalyst LF 316 60 l/h Service life: change catalyst every 6 months as a preventative measure. The stainless steel catalyst is not suitable for SO2containing combustion gases 32 System Components and Accessories for Sample Gas Conditioning arbitrary arbitrary arbitrary vertical 10/23-5.20 EN January 2004 Reaction Element Application and description The reaction element with UV lamp is used for gases which react chemically under the influence of UV light. A typical application is the conversion of hydrogen (H2) with chlorine (Cl2) into hydrochloric acid (HCl). For chlorine concentrations of less than 85 Vol.-%, however, the tubular furnace CGO-9 should be used in principle. The sample gas is irradiated in a quartz reaction vessel by a UV lamp. The lamp is mounted in the centre of the reaction vessel so that the UV light radiates to all sides. This device is housed in a plastic case. The formation of ozone outside the reaction vessel is prevented by purging the case with nitrogen or instrument air. Technical data Sample gas pressure pabs = 80...150 kPa (0.8...1.5 bar) Dead volume of the reaction tube approx. 250 cm3 Service life of the UV lamp approx. 5 months Dimensional drawing (dimensions in mm) Power supply 230 VAC, 50 Hz Power consumption 0.5 A during start-up, 0.35 A in continuous operation 6 Case material Glass-fiber-reinforced polyester Weight 2 kg 1 Degree of protection of housing IP54 to EN 60529 2 3 Materials of the gas-conducting parts Viton, quartz 4 Electrical connection Terminals via PG 11 cable gland 5 Gas connection Glass tube with 7 mm outer ∅ for tube with 6 mm inner ∅ and 9 mm outer ∅ Case purging approx. 10 l/h nitrogen or instrument air 1 2 3 Purge gas outlet Sample gas outlet Power supply 4 5 6 Sample gas inlet Purge gas inlet Cable gland Ordering information Catalog No. Reaction element with UV lamp 10/23-5.20 EN January 2004 23095-5-5854124 System Components and Accessories for Sample Gas Conditioning 33 Membrane Filter Application Dimensional drawings (dimensions in mm) Membrane filters are used in gas conditioning systems of analyzer equipment for fine filtering of dust particles ≥ 1 µm, in order to protect the analysis instruments from contamination in the event of disturbances in the sample gas conditioning chain. Membrane filter, PVC version Technical data Flow rate (air) max. 300 l/h Gas pressure pabs PVC: max. 150 kPa (1.5 bar), stainless steel: max. 200 kPa (2 bar) Gas temperature PVC: max. 55 °C, stainless steel: max. 100 °C Retention rate 100 % for particles ≥ 1 µm Pressure drop 2.5 to 20 hPa (mbar) at a flow rate of 30...250 l/h (air) Materials of the gas-conducting parts Case: PVC or stainless steel (Mat. No. 1.4571), gas connections: Hostaflon, round cord rings: Viton, filter membrane: glass fiber Filter surface approx. 24 cm2 Dead volume approx. 15 cm3 Membrane filter, stainless steel version Weight PVC: approx. 0.59 kg, stainless steel: approx. 1.4 kg Mounting Panel and wall mounting (with mounting bracket) Gas connections G 1/4 (DIN lSO 228/1) or nozzles for hose internal diameter 4 mm Scope of delivery Membrane filter, mounting bracket, 2 nozzles, 2 round cord rings, 50 filter membranes Ordering information Catalog No. Membrane filter Membrane filter, PVC 23145-5-8018438 Membrane filter, stainless steel 23147-5-8018439 Condensate monitor (see page 35) Condensate monitor, PVC 23158-5-8018440 Condensate monitor, stainless steel 23157-5-8018039 34 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 CGKW Condensate Monitor Application The condensate monitor CGKW is used to indicate moisture (condensate) or any other electrically-conducting liquid which penetrates into the sample gas line to the gas analyzer. At the same time, the condensate monitor is a membrane filter and it therefore satisfies the double function of fine filtering the sample gas as well as of signaling moisture. The filter membrane holds back the penetrated concentrate for a short while. An independent condensate barrier (see application examples) can be constructed with the condensate monitor as sensor element and the switching unit ER-144A/Ex (see page 36). switching unit ER-144A/Ex, the apparatus is permitted in hazardous areas of Zones 1 and 2 up to a gas and ambient temperature of 55 °C without restriction of the explosion groups and temperature classes. Application examples The process gas is present at zero pressure or with negative pressure Sample gas feeding by pump. Condensate barrier by switching off the pump. Condensate monitor and analyzer must be arranged above the sample gas conditioning chain. Technical data Flow rate (air) max. 300 l/h Gas pressure pabs PVC: max. 150 kPa (1.5 bar), stainless steel: max. 200 kPa (2 bar) Gas temperature max. 55 °C Retention rate 100 % for particles ≥ 1 µm Pressure drop 2.5 to 20 hPa (mbar) at a flow rate of 30...250 l/h (air) Materials of gas-conducting parts Case: PVC or stainless steel (Mat. No. 1.4571), gas connections: Hostaflon, electrodes: stainless steel (Mat. No. 1.4305), round cord rings: Viton, filter membrane: glass fiber The process gas is present at zero pressure or with weak positive pressure Sample gas feeding by pump. Condensate barrier by switching off the pump and switching over a 3/2-way solenoid valve. Condensate monitor and analyzer can be arranged as you wish. Filter surface approx. 24 cm2 Dead volume approx. 15 cm3 Dimensions as for membrane filter (see page 34) Weight PVC: approx. 0.71 kg, stainless steel: approx. 1.5 kg Mounting Panel and wall mounting (with mounting bracket) Gas connections G 1/4 (DIN lSO 228/1) or nozzles for hose inside diameter 4 mm The process gas is present with positive pressure Sample gas feeding by positive pressure. Condensate barrier by switching over a 3/2-way solenoid valve. Condensate monitor and analyzer can be arranged as you wish. Electrical connections Two-core cable, approx. 1 m, for connecting to the switching unit ER-144A/Ex (see page 36) Mounting orientation Safety nose at top, electrode below Scope of delivery Condensate monitor, mounting bracket, 2 nozzles, 2 round cord rings, 25 filter membranes, operating manual Explosion protection (only with stainless steel case) The condensate monitor is a device without voltage source (VDE 0165/2.91 Section 6.1.3.1.3). If the condensate monitor is being operated in the intrinsically-safe control circuit of the 10/23-5.20 EN January 2004 1 2 3 1) Membrane pump 4 Switching unit 7 Analyzer Condensate monitor 5 Pilot lamp 6 Flow meter Solenoid valve 1) The sample gas path to the analyzer is blocked in the deenergized condition System Components and Accessories for Sample Gas Conditioning 35 ER-144A/Ex Switching Unit Application and description Dimensional drawing (dimensions in mm) The switching unit ER-144A/Ex acts as switching amplifier for the condensate monitor CGKW (see page 35). The intrinsicallysafe circuit of the switching unit ER-144A/Ex enables the condensate monitor also to be installed in hazardous areas. The ER-144A/Ex switching unit operates in closed-circuit operation. The alarm positions of the output contacts correspond to those of the device in a non-voltage state or exceeding the adjustable measurement current value (electric conductance) or disconnection of the sensor lead. In the “Ready” status, the output contacts have changed over to the corresponding counter-position (internal relay picked-up). 144/A 99 A 100-kΩ resistor (1 % / 0.25 W) must be installed at the sensor in order to monitor the signal line between the sensor and the electrode relay. Without the resistor, the switching unit will change to the “Line break” position. Technical data Electrical connections Indication One LED each for line breakage and condensate penetration NO2 12 11 14 22 21 24 COM2 21 22 24 12 NO1 Output 2 potential-free changeover contacts, max. 250 V AC, 5 A 14 11 N L1 NC2 “ib” ≤ 13.1 V ≤ 5 mA ≤ 65 mW ≤ 6 µF ≤1H NC1 “ia” ≤ 13.1 V ≤ 5 mA ≤ 65 mW ≤ 0.97 µF ≤ 0.9 H COM1 Input No-load voltage U0 Short-circuit current I0 Power P0 Permissible external capacitance C0 Permissible external inductance L0 Power supply 230 V AC or 115 V AC ±10 %, 48...62 Hz, ≤ 1 VA Construction Surface-mounting case Degree of protection Housing IP 40, terminals IP 20 to EN 60529 Electrical safety Protection class II, Over-voltage category III, Degree of pollution 2 E1 E2 E1 E2 Weight approx. 0.2 kg Mounting Snap fastening on standard rail 35 mm (EN 50022) Relays are shown in the unpowered state. Ambient temperature –25...+60 °C Ordering information EC type examination certificate TÜV 00 ATEX 1604 Designation II (1) G [EEx ia] IIC Catalog No. Switching unit ER-144A/Ex, 230 V AC 23371-4-0730637 Switching unit ER-144A/Ex, 115 V AC 23371-4-0730638 Installation location Outside the hazardous area 36 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 Acid Filter Application and description Dimensional drawing (dimensions in mm) The acid filter is used in the gas conditioning system. Its purpose is to collect the sulfuric acid aerosols entrapped in the sample gas. The acid filter may always be required where the SO3 content in the sample gas is greater than 1 mg/m3 or the SO2 content is greater than 1000 mg/m3 – for example in flue gas from heavy-oil or hard coal firings. 140 20 65 6,5 60 85 The filter element is made up of borosilicate fibers. An influencing and “hang-up” of the measuring component in the sample gas is not detectable with this material. 78 36 50 Technical data DN4/6 ca. 25 Flow rate (air) max. 250 l/h 23.5 Gas pressure pabs = 50...200 kPa (0.5...2 bar) Ordering information Sample gas temperature max. 150 °C Catalog No. Acid filter Sample gas dew point max. 70 °C 23045-5-8018419 Retention rate 99.99 % for particles ≥ 0.1 µm Pressure drop 10 hPa at 250 l/h, 50 hPa at 250 l/h Dead time approx. 20 s Materials of gas-conducting parts Connection cap: PVDF; vessel: glass; filter element: borosilicate glass micro fiber Dead volume approx. 130 ml Dimensions see dimensional drawing Weight approx. 0.57 kg Mounting Wall mounting with mounting bracket, mounting orientation vertical Gas connections Male fitting (PVDF) for 4/6/1 mm, drainage connection GL14 with terminal fitting 4/6/1 mm (PVDF) Ambient temperature +5...+50 °C Service life Change element if there is contamination and perceptibly higher pressure drop Scope of delivery Filter vessel with filter element, two male fittings, drainage connection GL14, mounting bracket, mounting and replacement instructions 10/23-5.20 EN January 2004 System Components and Accessories for Sample Gas Conditioning 37 Disposable Filter Application and description Dimensional drawing (dimensions in mm) The disposable filter is used in the gas conditioning system. It is mounted in the sample gas line upstream of the gas analyzer. The disposable filter consists of a micro fiber filter pipe which is welded into a plastic case. Technical data Flow rate (air) max. 250 l/h Gas pressure pabs ≤ 200 kPa (2 bar) Sample gas temperature +5...+50 °C Retention rate 99.99 % for particles ≥ 0.1 µm Ordering information Catalog No. Pressure drop approx. 2 hPa at 60 l/h Disposable filter 23044-5-8018418 Dead time approx. 3 s at 60 l/h Materials of gas-conducting parts Case: nylon, filter element: borosilicate glass micro fiber Case volume 11.5 cm3 Dimensions Height 80 mm, diameter 28 mm Weight approx. 0.1 kg Mounting Mounting orientation preferably vertical Gas connections Two pipe nipples, outside diameter 6.3 mm Ambient temperature +5...+50 °C Service life Change filter if there is condensate accumulation (acid), and in any case every 6 months Scope of delivery Disposable filter, mounting and replacement instructions 38 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 Flow Meters, Flow Monitors ! ! ! ! Flow measurement using float-type flow meters Replaceable measuring tube Integral needle valve Flow monitor with inductive contact Flow meter 7...70 l/h Dimensional drawing (dimensions in mm) Measuring range 7...70 l/h nitrogen at 20 °C and 1013 hPa (mbar) The following flow rates are obtained with other gases under the same conditions at the 60 l/h mark (approximate values): Sulfur dioxide SO2 48 l/h Carbon dioxide CO2 51 l/h Argon Ar 54 l/h Air 59 l/h 63 l/h Oxygen O2 Carbon monoxide CO 68 l/h Methane CH4 98 l/h 156 l/h Hydrogen H2 Helium He 213 l/h Measuring deviation ±5 % of the full-scale value Gas inlet conditions Pressure max. 16 MPa (16 bar), temperature 100 °C Flow rate adjustment with integral needle valve Materials Measuring tube Float Float catcher Fitting Needle valve Seals Nozzles borosilicate glass stainless steel Mat. No. 1.4401 PTFE stainless steel Mat. No. 1.4571 stainless steel Mat. No. 1.4571 Viton Hostaflon 1 Gas inlet 2 Gas outlet Weight approx. 0.5 kg Mounting Panel or wall mounting by means of mounting bracket Gas connections 1/4 NPT female thread or sleeve for hose 4 mm ID Scope of delivery Flow meter, mounting bracket, 2 nozzles 10/23-5.20 EN January 2004 System Components and Accessories for Sample Gas Conditioning 39 Flow Meters, Flow Monitors Flow monitor 1.6...16 l/h, 7...70 l/h Dimensional drawing (dimensions in mm) Measuring range 1.6...16 l/h or 7...70 l/h nitrogen at 20 °C and 1013 hPa (mbar) Measuring deviation ±5 % of the full-scale value Flow rate adjustment with integral needle valve Materials as with flow meter 7...70 l/h Weight approx. 0.8 kg Mounting as with flow meter 7...70 l/h Gas connections as with flow meter 7...70 l/h Signaling with inductive contact RC 10-14-NO Float catcher set to 5 l/h or 20 l/h Electrical connections Terminal boxes with EMC filter and cable gland PG 11 Scope of delivery Flow monitor, mounting bracket, 2 nozzles, O-ring Flow monitor for chlorine 7...70 l/h Measuring range 7...70 l/h chlorine at 20 °C and 1013 hPa (mbar) 1 Gas inlet 2 Gas outlet Ordering information Catalog No. Flow meter 7...70 l/h 23151-5-8018474 Measuring deviation ±5 % of the full-scale value Flow monitor 1.6...16 l/h 23155-5-8018476 Flow monitor 7...70 l/h 23155-5-8018475 Gas inlet conditions Pressure max. 10 MPa (10 bar), temperature 20 °C Flow monitor for chlorine 7...70 l/h 23155-5-8018477 Flow rate adjustment with integral needle valve PEEK Materials Measuring tube Float Float catcher Case Seals borosilicate glass PEEK with lining PTFE PVDF FFKM Weight approx. 0.5 kg Mounting Panel or wall mounting by means of mounting bracket Gas connections 1/4 NPT female thread Signaling with inductive contact RC 10-14-NO Float catcher set to 20 l/h Electrical connections Terminal boxes with EMC filter and cable gland PG 11 Scope of delivery Flow monitor, mounting bracket, 2 nozzles, O-ring 40 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 KFA Isolated Switch Amplifier Application and description The KFA isolated switch amplifier is used as switch amplifier for the flow monitor (see page 39). The control circuit is monitored for line breakage and short circuit. External faults are indicated by a red flashing LED. Technical data Input (intrinsically safe) U0 ≤ 10.6 V I0 ≤ 19.1 mA P0 ≤ 51 mW Permissible connection values Explosion group IIA External capacitance 72 µF External inductance 780 mH IIB 16.2 µF 390 mH IIC 2.32 µF 97 mH Output relays Potential-free changeover contacts, max. 253 V AC, 2 A; cos ϕ > 0.7; switching frequency < 10 Hz Power supply 207...253 V AC or 103.5...126 V AC, 45...65 Hz, ≤ 1 VA Electrical connections Degree of protection of housing IP 30 to EN 60529 Input I EEx ia IIC Input II EEx ia IIC 1+ 4+ Switch S3 in position I 3- 6- 400 Ω ≤ R ≤ 2 kΩ Weight approx. 150 g 1+ Mounting Panel or wall mounting with screw fastening (EN 50022/3) or snap fastening on standard rail 35 mm (EN 50022) 10 kΩ 400 Ω ≤ R ≤ 2 kΩ 3- Switch S3 in position I 10 kΩ 4+ 6- Switch S3 in position I without SC 10 kΩ 2+ without LB, SC 1+ 1+ 10 kΩ 3- 2+ 3- 4+ 3- 4+ 5+ 6- 5+ 6- Hazardous area, zone 0, zone 1 Construction Surface-mounting case Switch S3 in position II 6- Ambient temperature –20...+60 °C I II S1 Designation II (1) G D [EEx ia] llC Installation location Outside the hazardous area LB SC S3 red I II S2 & S3 red + - & 1 Safe area LB SC EC type examination certificate PTB 00 ATEX 2081 green yellow yellow + 7 8 9 Output I 10 11 12 Output II 14 15 Power supply - Power LB/SC Rail collective error message only KFD2-SR2-Ex2.W Ordering information Catalog No. 10/23-5.20 EN January 2004 KFA6-SR2-Ex1.W, 1 channel, 230 V AC 23372-5-8328644 KFA6-SR2-Ex2.W, 2 channels, 230 V AC 23372-5-8328645 KFA5-SR2-Ex1.W, 1 channel, 115 V AC 23372-5-8328851 KFA5-SR2-Ex2.W, 2 channels, 115 V AC 23372-5-0730651 System Components and Accessories for Sample Gas Conditioning 41 Stripper for Cooling Water and Waste Water Application and description The stripper enables traces of organic solvents or pollution in waste water or cooling water to be monitored continuously. The stripper is used in combination with a flame-ionization detector (FID). The device operates on the flow principle. 100...300 l/h of the water to be analyzed are sent through a glass body in the center of which is located a glass frit which is continuously purged with the instrument air. Hydrocarbons change into the gas phase and are driven out of the medium by the air bubbles. The air stream is then analyzed with an FID. The stripper unit is operated on the bypass principle without a pump. The cross-sections of the entire unit are designed in such a way that clogging is prevented to a greater or lesser extent. A threefold safeguard against flooding and water breakthrough to the FID is achieved by an overflow and an emergency overflow as well as a check valve. The feed can be shut off by means of a gate valve. To obtain long-term measurement stability, the strip air is fed via flow regulators. Technical data Instrument air 100...700 kPa (1...7 bar), consumption approx. 100 l/h Minimum pressure difference 10 kPa (0.1 bar) Medium temperature +10...+50 °C Connections Connection, test water: 1 inch thread connection Connection, sample water: DN 25 using DIN 4-hole flange with flat seal Discharge, sample water: Discharge point DN 50 via DIN 4-hole flange with flat seal Contacts Potential-free contact for flow monitoring of the sample water Flow rate sample water 100...300 l/h Heat-up time < 7 s with 3 m feed line between stripper and FID Materials of gas-conducting parts Rigid PVC, glass Power supply 230 VAC, 50/60 Hz or 120 VAC, 60 Hz Ambient temperature +10...+50 °C Ordering information Catalog No. Stripper IP 65, unheated 23841-5-4560001 Stripper IP 65, heated, 230 VAC 23841-5-0768362 Stripper IP 65, heated, 120 VAC 23841-5-0768361 System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 Case material G.R.P. Degree of protection of housing IP 65 to EN 60529 Dimensions 1000 x 460 x 340 mm (H x W x D) Weight 24 kg 42 Multi-way Test Gas Cocks Multi-way test gas cock, PVDF version Flow rate approx. 1000 l/h at 100 hPa pressure difference and 20 °C Gas pressure pabs = 50...200 kPa (0.5...2 bar) Leakage rate ≤ 5 x 10–3 hPa I/s Materials of gas-conducting parts PVDF, PTFE, Viton Weight approx. 0.7 kg Mounting Wall or panel mounting Gas connections G1/4 (DIN ISO 228/1) Ambient temperature +5...+80 °C Multi-way test gas cock, stainless steel version Dimensional drawing (dimensions in mm) Leakage rate ≤ 5 x 10–3 hPa l/s Materials of gas-conducting parts PTFE, stainless steel SS 316, suitable for pure oxygen 94 62,5 ~110 Gas pressure pabs = 17.6 MPa (176 bar) ~124 Flow rate approx. 1000 l/h at 50 hPa pressure difference and 20 °C 75 82 Weight approx. 0.8 or 0.45 kg Mounting Wall mounting (with accessories) or panel mounting Nullgas Zero gas Messgas Meas.gas Gas connections 1/8-NPT and screw fitting for 6 mm OD pipes Ambient temperature +10...+65 °C Endgas 1 Span gas 83 Ordering information Catalog No. Test gas cock PVDF 23177-4-0839859 Test gas cock stainless steel 90805-4-0890875 Montagebohrung Bore holes 45° 63 M6 Test gas cock stainless steel for wall mount. 90805-5-8308581 10/23-5.20 EN January 2004 System Components and Accessories for Sample Gas Conditioning 43 Cylinder Pressure Reducers Application and description Cylinder pressure reducers are used to reduce the filling pressure in pure gas and test gas cylinders to the required operating pressure. Material compatibility must be observed in respect of the test gas (see technical data). Two-stage cylinder pressure reducers are employed where very constant pressure and flow are required at low operating pressure – for example where the subsequent gas paths are switched over using solenoid valves. Pressure reducers with minimum contact at the high-pressure gauge give an indication when the cylinder pressure has dropped to such a level that it is necessary to replace the gas cylinder. Ordering information Catalog No. 2-stage for nitrogen 23422-5-8018376 2-stage for non-corrosive test gases 23422-5-8018377 2-stage for corrosive test gases 23422-5-8018378 1-stage for nitrogen, brass 23422-4-0730654 1-stage for non-corrosive test gases, brass 23422-4-0730655 2-stage for hydrogen, brass 23422-4-0730652 2-stage for hydrogen, stainless steel 23422-4-0730653 Technical data Catalog No. Gas type Construction Inlet pressure Outlet pressure (adjustable) Safety valve set to Relief valve set to Pressure gauge indication Inlet pressure Outlet pressure Flow rate Control action Status signal Materials Membranes Seal Case Dimensions (W x H x D) Weight Connections Connection to cylinder (thread to DIN 477) Gas outlet Safety valve Relief valve Ambient temperature Scope of delivery Dimensional drawing 44 23422-5-8018376, 23422-5-8018377 Nitrogen, non-corrosive test gases 2-stage, brass, with minimum contact max. 21 MPa (210 bar) 10...50 kPa (0.1...0.5 bar) approx. 1.6 MPa (16 bar) approx. 70 kPa (approx. 0.7 bar) 23422-5-8018378 Corrosive test gases 2-stage, stainless steel, with min. contact max. 21 MPa (210 bar) 10...50 kPa (0.1...0.5 bar) approx. 1.6 MPa (16 bar) approx. 70 kPa (approx. 0.7 bar) 0...25 MPa (0...250 bar) –100...+150 kPa (–1...+1.5 bar) 25...500 l/h Back pressure increase with falling cylinder pressure down to 3 bar equals zero Reed contact 100 V, 0.5 A 0...25 MPa (0...250 bar) –100...+150 kPa (–1...+1.5 bar) 25...500 l/h Back pressure increase with falling cylinder pressure down to 3 bar equals zero Reed contact 100 V, 0.5 A Stainless steel ETFE, PVDF, EPDM Brass chromium plated approx. 160 x 185 x 167 mm approx. 2.1 kg Stainless steel ETFE, PVDF, EPDM Stainless steel 1.4401 approx. 160 x 185 x 167 mm approx. 2.1 kg Hexagon Hexagon Clamping ring screw fitting Swagelok® for pipe with 6 mm outside diameter Clamping ring screw fitting Swagelok® for pipe with 6 mm outside diameter 1/4-NPT male thread –5...+75 °C Pressure reducer, pressure gauge, safety valve and clamping ring screw fitting attached; replacement seals, manual see above Clamping ring screw fitting Swagelok® for pipe with 6 mm outside diameter Clamping ring screw fitting Swagelok® for pipe with 6 mm outside diameter 1/4-NPT male thread –5...+75 °C Pressure reducer, pressure gauge, safety valve and clamping ring screw fitting attached; replacement seals, manual System Components and Accessories for Sample Gas Conditioning 10/23-5.20 EN January 2004 Cylinder Pressure Reducers Technical data Catalog No. Gas type Construction Inlet pressure Control range Control action Pressure gauge Reed contact pressure gauge Contact Outlet pressure gauge indication range Materials Body Membrane Case seal Seat Filter Connection cable Bottle connection Safety relief valve Ambient temperature Weight Special features 23422-4-0730652 Hydrogen 2-stage, brass 21 MPa (210 bar) 0...350 kPa (3.5 bar) Back pressure increase with falling cylinder pressure down to 3 bar equals zero – 25 MPa (250 bar) 23422-4-0730653 Hydrogen 2-stage, stainless steel 21 MPa (210 bar) 0...350 kPa (3.5 bar) Back pressure increase with falling cylinder pressure down to 3 bar equals zero – 25 MPa (250 bar) 23422-4-0730654 Nitrogen 1-stage, brass 21 MPa (210 bar) 0...250 kPa (2.5 bar) – 23422-4-0730655 Non-corrosive test gas 1-stage, brass 21 MPa (210 bar) 0...250 kPa (2.5 bar) – 31.5 MPa (315 bar) – 31.5 MPa (315 bar) – falling opening –100...+500 kPa (–1...+5 bar) falling opening –100...+500 kPa (–1...+5 bar) – 0...+400 kPa (0...+4 bar) – 0...+400 kPa (0...+4 bar) Brass Stainless steel Perbunan PVDF/PTFE 50 µm 3m DIN 477, No. 1 2 –5...+75 °C 2.1 kg Outlet with throttle approx. 40 l/h and 6 mm screwed fitting Stainless steel 1.4404 Stainless steel EPDM PVDF/PTFE 50 µm 3m DIN 477, No. 1 2 –5...+75 °C 2.1 kg Outlet with throttle approx. 40 l/h and 6 mm screwed fitting Brass Perbunan Perbunan – 100 µm – DIN 477, No. 10 1 –5...+75 °C 2.1 kg Brass Perbunan Perbunan – 100 µm – DIN 477, No. 14 1 –5...+75 °C 2.1 kg Dimensional drawings 10/23-5.20 EN January 2004 System Components and Accessories for Sample Gas Conditioning 45 The IndustrialIT word mark and all mentioned product names in the form XXXXXIT are registered or pending trademarks of ABB. ABB has Sales & Customer Support expertise in over 100 countries worldwide. The Company’s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (01.04) ABB Automation Products GmbH Analytical Division Stierstaedter Strasse 5 D60488 Frankfurt am Main Phone: +49 69 793040 Fax: +49 69 79304566 EMail: [email protected] 10/235.20 EN Rev. 5 ABB 2004 www.abb.com
© Copyright 2024