PowerPrepTM Sample Cleanup System Automated Sample Clean-up Power-Prep™ is changing the face of high speed sample processing in today’s laboratories. The automated liquid chromatography system performs simultaneous sample processing automatically and unattended. You need only to load your samples, snap on your pre-packed columns and press the start key. The system performs the entire sample cleanup and fractionation for six samples automatically including sample loading, washing, elution and fraction collection. Sample Type: The Power-Prep concentrates and separates analytes from a variety of sample extracts such as: EPA SW-846 methods for pesticides, PCBs and PAHs sample analysis. The Power-Prep™ system fits into the smallest budget. With its modular design, you can cost effectively automate your extraction and sample clean-up procedures by purchasing a 1-sample system and expand it to 5 or 10 samples as needed. Rapid Sample Processing The Power-Prep™ system automates the sample cleanup process to be completed in hours versus days. For example it separates Dioxins, PCBs, and Pesticides for 5 samples in less than one hour. Cost Effective & Reliable Analysis With a few keystrokes, the Power-Prep system performs an entire column chromatography, automatically achieving consistent and high recoveries for all analytes. The unattended operation feature of the system saves labor and valuable time. The Power-Prep system reduces the amount of glassware and solvents required for manual sample clean-up. Power-Prep automates Sample clean-up specifically by EPA SW 846 methods for Dioxins, PCBs, Pesticides and PAHs. High Recovery of all Analytes Power-Prep Processes up to 6 samples simultaneously and produces high recoveries for all analytes of interest. Modular, Expandable, & Affordable A Power-Prep system can be expanded from one to a 10 sample configuration. Both expansion and module replacement are done via FMS’s quick connect modules. This reduces system down time and increases laboratory throughput. Eliminating cross contamination from sample to sample. Disposable Columns The Power-Prep System uses pre-packed disposable columns. FMS’s proprietary columns are made from Teflon and contain multi layer silica, alumina, and carbon. FMS’s pre-packed columns are tested for purity and performance prior to shipment. Eliminating cross contamination from sample to sample. Electronic Documentation The DMS-6000 real time software allows control of 6 channels of flow rates, volumes, sample size, column selection, solvent selection and fraction collection. This allows automatic documentation of the entire process. When combined with extraction the temperature and pressure can be superimposed and printed in graphic or tabular format and stored for future reference. Multiple Method Storage The DMS-6000 Editor allows multiple methods to be stored in the system. In each method parameters such as time, solvent volume and final temperature can be set for each step. Pressure and temperature as well as dispensed volumes are displayed every second and stored for future reference. Economical System Platform Power-Prep fits the smallest budgets. Due to its modular design, The Power-Prep can be purchased in one or three sample configuration and expanded to five or ten when needed. Product Information: Hardware Each Power-Prep™ system contains multiple quick connect modules consisting of: • • • • • Power Supply Module Control Module Pump & Pressure Modules Valve Drive Modules Sample Processing Modules The Power-Prep modules are mounted vertically on a portable cabinet. It is a self contained system that also provides storage for solvent bottles, waste and collectors. Software: FMS’s powerful, easy to use, windows-based monitoring and control software is extremely flexible. It includes functions to develop and optimize methods. Input parameter includes flow rates, volumes, column selection, sample size, solvent selection and fraction collection. System Configurations: Power-Prep™/p (Parallel) Parallel sample clean-up System for Dioxins, PCBs and Pesticides sample analysis. Capacity: 1 to 10 samples Processing time: 1 hour per run Columns: o Multi-layer Silica o Alumina o Carbon Column Material: Teflon Power-Prep™/s (Sequential) Sequential sample clean-up System for Dioxins, PCBs and Pesticides sample analysis. Capacity: 5 samples Processing time: 5 hours per run Columns: o Multi-layer Silica o Alumina o Carbon Column Material: Teflon Power-Prep™/SPE Automated Solid Phase Extraction System for automating EPA, SW-846 methods for pesticides, PCBs and PAHs sample analysis Capacity: 5 to 25 samples Processing time: 1 to 5 hours per run Columns: o Silica o Alumina o Carbon o Florisil o C18 Column Material: Teflon, Polypropylene How it works Contact Us FMS, Inc 580 Pleasant Street Watertown, MA 02472 P: 617-393-2396 F: 617-393-0194 E: [email protected] www.fmsenvironmental.com Six Position Power-Prep Sample Cleanup
© Copyright 2024