INSPECTION REPORT For the Property at: 1220 SAMPLE REPORT ST VISTA, CA 92084 Prepared for: JOHN DOE Inspection Date: Friday, October 12, 2012 Prepared by: Robert Guarino Advantage Home Inspection Service, Inc. 1081 Camino del Rio So., Suite 216, Suite 216 San Diego, CA 92108 619-543-0691 Fax: 619-543-0163 http://advantagehomeinspection.net [email protected], [email protected] The best home inspection experience available. October 24, 2013 Dear John Doe, RE: Report No. 1197 1220 Sample report St Vista, CA 92084 Thanks very much for choosing us to perform your home inspection. The inspection itself and the attached report comply with the requirements of the Standards of Practice of our national Association. This document defines the scope of a home inspection. Clients sometimes assume that a home inspection will include many things that are beyond the scope. We encourage you to read the Standards of Practice so that you clearly understand what things are included in the home inspection and report. http://www.ashi.org/documents/pdf/standards.pdf The report has been prepared for the exclusive use of our client. No use by third parties is intended. We will not be responsible to any parties for the contents of the report, other than the party named herein . The report is effectively a snapshot of the house, recording the conditions on a given date and time. Home inspectors cannot predict future behavior, and as such, we cannot be responsible for things that occur after the inspection. If conditions change, we are available to revisit the property and update our report. The report itself is copyrighted, and may not be used in whole or in part without our express written permission. Again, thanks very much for choosing us to perform your home inspection. Sincerely, Robert Guarino on behalf of Advantage Home Inspection Service, Inc. Advantage Home Inspection Service, Inc. 1081 Camino del Rio So., Suite 216, Suite 216 San Diego, CA 92108 619-543-0691 Fax: 619-543-0163 http://advantagehomeinspection.net [email protected], [email protected] INVOICE October 24, 2013 Client: John Doe Report No. 1197 For inspection at: 1220 Sample report St Vista, CA 92084 on: Friday, October 12, 2012 Fourplex: 4 homes in one building $800.00 Total $800.00 Advantage Home Inspection Service, Inc. 1081 Camino del Rio So., Suite 216, Suite 216 San Diego, CA 92108 619-543-0691 Fax: 619-543-0163 http://advantagehomeinspection.net [email protected], [email protected] Report No. 1197 AGREEMENT 1220 Sample report St, Vista, CA October 12, 2012 http://advantagehomeinspection.net PARTIES TO THE AGREEMENT Company Advantage Home Inspection Service, Inc. 1081 Camino del Rio So., Suite 216, Suite 216 San Diego, CA 92108 Client John Doe Total Fee: $800.00 This is an agreement between John Doe and Advantage Home Inspection Service, Inc.. ADVANTAGE HOME INSPECTION AGREEMENT THIS AGREEMENT LIMITS OUR LIABILITY-PLEASE READ CAREFULLY The Advantage Home Inspection Agreement (the Agreement) is made effective on the date stated on Page 2 of this agreement by and between Advantage Home Inspection Service (hereinafter Advantage, we, us and our) and client named on page 2 of this agreement (hereinafter client, you or your) (collectively parties). We are independently owned and operated, engaged in the business of providing home inspection services. You desire to have a general home inspection (the inspection) performed on a home located at the address stated on page 2 of this agreement. FEE: You agree to pay the fee stated on Page 2 of this agreement for the performance of the Inspection service(s). This amount shall be paid in full prior to the completion of the inspection (unless otherwise agreed in writing by the parties). Should you fail to timely pay the agreed upon fee(s), you shall be responsible for paying any and all fees associated with collection, including but not limited to administration costs, attorneys fees, and cost of litigation. SCOPE OF THE INSPECTION: This Inspection is a limited visual examination of certain readily accessible systems and components (designated for Inspection herein) using normal operating controls and opening readily openable access panels. The purpose of the Inspection is to provide you with information about the condition of certain systems and components of the home at the time of the Inspection. The Inspection will be performed in accordance with the Standards of Practice of the American Society of Home Inspectors (the ASHI Standard). (a copy of which is available from us upon request and should be reviewed by you prior to accepting our services). The ASHI standards are hereby incorporated by reference in their entirety and are hereby made a part of this Agreement. All terms used herein and not otherwise defined shall have the meaning set forth in the ASHI Standards. The inspector is a generalist and is not a licensed engineer or expert in any specific craft or trade. If the inspector recommends further action, including (but not limited to) consulting with a specialized expert(s), you must do so at your expense or otherwise assume all risks associated with failure to do so. This inspection is not technically exhaustive. The fee charged for this Inspection is substantially less than that of a technically exhaustive inspection. A written Inspection Report will be provided describing the following systems and components: structural components (including foundation and framing), exterior, roof system, plumbing system, electrical system, heating system, installed central and through-wall air conditioning systems, interiors, insulation & ventilation, and fireplaces & solid fuel burning appliances. The Report will identify the following: (a) which systems and components designated for inspection herein are, in the professional opinion of the inspector, significantly deficient or near the end of their service lives. (b) why the inspector deems the system or component to be significantly deficient or near the end of its service life, (c) whether further evaluation, correction or monitoring is needed, and (d) whether any system or component described herein was not inspected and why it was not inspected. We reserve the right to modify the Report for a period of time that shall not Providing great home inspections for every client every time Report No. 1197 AGREEMENT 1220 Sample report St, Vista, CA October 12, 2012 http://advantagehomeinspection.net exceed forty-eight (48) hours after the Report has been first delivered to you. Nothing in this Agreement is intended to limit the inspector from reporting observations and conditions in addition to those identified herein or excluding systems and components from the Inspection if agreed to in writing and signed by the parties. Should we, as a courtesy, exceed any particular requirement set forth herein in one area, we shall not be obligated to exceed the requirements in other areas. EXCLUSIONS: A system or component is not readily accessible if because it is concealed or inaccessible due to obstructions, including (but not limited to) floor coverings, suspended ceiling tiles, insulation, furniture or other personal property, soil, vegetation, water, ice or snow cannot be inspected. We are not required to move or disturb such items in order to diminish or eliminate the obstruction. We are not required to report on or engage in any practice or act that is not included or that is specifically excluded in the ASHI Standards unless otherwise agreed to in writing signed by the parties. We are not required to inspect anything identified in the ASHI Standards as limitations or exclusions specific to the systems and components inspected. The list of the following specific exclusions is not an exhaustive list; see ASHI Standards for additional exclusions and limitations. We are NOT required to determine the following: remaining life of any system or component, the causes of any condition or deficiency, methods and costs of corrections, suitability of the property for a specialized use, market value or marketability, advisability of purchase of the property, the presence of pests such as wood damaging organisms (including termites), rodents or insect, rot/decay, fungus, decorative items, underground items, breached thermal pane seals, or items not permanently installed. We are not required to do the following: predict future conditions including (but not limited to) failure of components, operate any system or component that is shut down or otherwise inoperable, light pilot lights, determine the presence of hazardous substances, enter hazardous areas, or perform engineering, architectural, plumbing, or any other job function requiring an occupational license or certification in your jurisdiction (unless the inspector holds a valid license or certification and the parties agree in writing signed by the parties on the additional service(s) for an additional fee). We are not required to inspect fences, soil conditions, spas, saunas, steam baths, pools (and related equipment), outbuildings (other than garage or carport), sprinkler systems, private and community waste disposal systems, telephones, cable television, intercoms, security systems, low voltage lighting systems, any timing systems, well systems, window-unit air conditioning system, and heating or cooling systems when weather conditions or other circumstances may cause equipment damage. We are not required to inspect cosmetic items such as paint, wallpaper, carpet, or other finishes on walls, ceilings or floors, and any type of window treatment (such as blinds or draperies). We are not required to determine non-compliance with manufacturers specifications or applicable regulatory requirements, including (but not limited to) building code compliance. Water/moisture, leaks, seepage and drainage problems are often only visible during or after a certain amount of rain. It is thus impossible to observe water/moisture, leaks, seepage and drainage problems unless the inspection is conducted during or immediately after a rain sufficient to reveal such problems. ADDITIONAL SERVICES: A general home inspection does not include, among other things, the following services: carbon monoxide test, radon gas test, lead-based paid test, water analysis, on-site waste disposal system inspection, basic energy assessment, wood destroying insects (or organisms) inspection, asbestos test, engineering services, or invasive testing of EIFS-Exterior Insulation & Finishing Systems (also known as artificial or synthetic stucco) to determine the existence of moisture and damage related thereto. We may be able to perform any one or more of these additional services upon your request for an additional fee (s). The terms of the performance of such services shall be defined in a separate agreement or addendum signed by the parties. DISPUTE RESOLUTION AND REMEDY LIMITATION: Notice of Claims. You understand and agree that any claim(s) or complaint(s) arising out of or related to any alleged act or omission of ADVANTAGE in connection with the Inspection shall be reported to us, in writing, within ten (10) business Providing great home inspections for every client every time Report No. 1197 AGREEMENT 1220 Sample report St, Vista, CA October 12, 2012 http://advantagehomeinspection.net days of discovery. Unless there is an emergency condition, you agree to allow us a reasonable period of time to investigate the claim(s) or complaint(s) by, among other things, re-inspection before you, or anyone acting on your behalf, repairs, replaces, alters or modifies the system or component that is the subject matter of the claim. You understand and agree that any failure to timely notify us and allow adequate time to investigate as stated above shall constitute a complete bar and waiver of any and all claims you may have against us related to the alleged act or omission unless otherwise prohibited by law. Arbitration - Any dispute, controversy, interpretation or claim including claims for, but not limited to, breach of contract, any form of negligence, fraud, or misinterpretation arising out of, from or related to, this contract or arising out of, from or related to the inspection or inspection report shall be submitted first to a Non-Binding Mediation conference and absent a voluntary settlement through Non-Binding Mediation to be followed by final and Binding Arbitration, if necessary, as conducted by Construction Dispute Resolution Services, LLC or Resolute Systems, Inc. utilizing their respective Rules and Procedures. If you would like to utilize the Mediation or Arbitration services of another dispute resolution provider other than one of those so stated please submit your recommendation to us for our consideration. If the dispute is submitted to Binding Arbitration, the decision of the Arbitrator appointed there under shall be final and binding and the enforcement of the Arbitration Award may be entered in any Court or administrative tribunal having jurisdiction thereof. NOTICE: YOU AND WE WOULD HAVE A RIGHT OR OPPORTUNITY TO LITIGATE DISPUTES THROUGH A COURT AND HAVE A JUDGE OR JURY DECIDE THE DISPUTES BUT HAVE AGREED INSTEAD TO RESOLVE DISPUTES THROUGH MEDIATION AND BINDING ARBITRATION. Limitations Period-Any legal action arising from this Agreement or from the Inspection and Report, including (but not limited to) the arbitration proceeding more specifically described above, must be commenced within one (1) year from the date of the inspection. Failure to bring such an action within this time period shall be a complete bar to any such action and a full and complete waiver of any rights, or claims based thereon. This time limitation period may be shorter than provided by state law. Limit of Liability Due to the nature of the services we are providing, it is difficult to foresee or determine (at the time this Agreement is formed) potential damages in the event of negligence or breach of this Agreement by us. Thus, if we fail to perform the Inspection as provided herein or are careless or negligent in the performance of the Inspection and/or preparing the Report our liability for any and all claims related thereto is limited to twice the fee paid for the Inspection or $500.00 (unless contrary to state law), and you release us from any and all additional liability. There will be no recovery for consequential damages. You understand that an inspection without this limitation of liability would be more technically exhaustive, likely require specialist(s) and would cost substantially more than the fee paid for this limited visual inspection. OTHER PROVISIONS: Confidentiality You understand that the Inspection is being performed (and the Report is being prepared) for your sole, confidential and exclusive benefit and use. The Report, or any portion thereof, is not intended to benefit any person not a party to this Agreement, including (but not limited to) the seller or the real estate agent(s) involved in the real estate transaction (third party). If you directly or indirectly allow or cause the Report or any portion thereof to be disclosed or distributed to any third party, you agree to indemnify, defend, and hold us harmless for any claims or actions based on the Inspection or the Report brought by the third party. Severability and Entire Agreement The parties agree that should an Arbitrator or Court determine that any provision(s) in the Agreement is void, voidable, or unenforceable, the remaining portions shall remain in full force and effect. This Agreement (in its entirety), and any attached, executed Addenda, contains the entire agreement between the parties, and Providing great home inspections for every client every time Report No. 1197 AGREEMENT 1220 Sample report St, Vista, CA October 12, 2012 http://advantagehomeinspection.net there are no other representations, warranties, or commitments, except as are specifically set forth herein. This Agreement supersedes any and all representations or discussions, whether oral or written, if any, among the parties relating to the subject matter of this Agreement. This Agreement may be modified, altered or amended only if agreed to in writing and signed by the parties. THE INSPECTION, INSPECTION AGREEMENT AND REPORT DO NOT CONSTITUTE A WARRANTY, AN INSURANCE POLICY, OR A GUARANTEE OF ANY KIND; NOR DO THEY SUBSTITUTE FOR ANY DISCLOSURE STATEMENT AS MAY BE REQUIRED BY LAW. By signing below you acknowledge that you have read, understand and agree to the terms and conditions of this agreement, including (but not limited to) the limitation of liability, arbitration clause and limitations period, and agree to pay the fee listed below. I, John Doe (Signature)___________________________, (Date)_______________, have read, understood and accepted the terms of this agreement. Providing great home inspections for every client every time Report No. 1197 SUMMARY 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR This Summary gathers together significant issues concerning the property. These can be simple repair or replacement issues as well as safety issues. This section is provided as a courtesy and cannot be considered a substitute for reading the entire report. Please read the complete document. Priority Maintenance Items Roofing General The roof has a wavy appearance to it at the mid section. There is also a blue tarp covering a part of the flat room near the Satellite antenna. The tarp was covered with bricks to keep it down. The comp shingles appear in serviceable condition with very little granule loss and all ridge tiles in place. The flat roof is older with noticeable patches. All debris must be removed from gutters, damage repaired, and extensions should be provided for downspouts to lead water away from the crawl space. I would advise asking a disclosure by the seller regarding the tarp on the roof. Secondly, I would advise consulting with a contractor to check out both the waviness of the roof as well as the angle on flat roof at 834 to insure that water will not pond on top and seep into the apartment below. Location: Roof Task: Further evaluation needed by a roofing contractor Exterior General We advise referring to structural pest inspection report. Please refer to pest control report for all issues concerning dry rot and termite damage on property. ROOF DRAINAGE \ Gutters Condition: Loose or damaged Front gutter at 834 is loose and damaged. It is torn in the rear section. Implication(s): Chance of water damage to contents, finishes and/or structure Location: Front gutter 834 Task: Repair or replace ROOF DRAINAGE \ Downspouts Condition: Should discharge 6ft. from building We advise adding an extension to lead water away from the home Implication(s): Chance of water damage to contents, finishes and/or structure WALLS \ Soffits and fascia Condition: Damage Some wood splitting noted at Fascia. Implication(s): Cosmetic defects | Chance of water damage to contents, finishes and/or structure Providing great home inspections for every client every time Page 1 of 38 Report No. 1197 SUMMARY 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR WALLS \ Stucco and EIFS Condition: Moisture penetration noted at exterior stucco. The stucco is flaking away and crumbling at various locations on property. A trowled area at the front of the property has been left unfinished between the two new vinyl window. Large patches have been noted. Moisture penetration and flaking noted at the rear wall of 834 addition. It would be wise to consult with a stucco specialist to make corrections before further deterioration occurs. Location: Exterior stucco Task: Repair where needed/Consult specialist EXTERIOR GLASS \ Storms and screens Condition: Make sure all window and door screens are present and in serviceable condition. This is considered part of normal home maintenance. PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Columns Condition: Support columns were added to support balcony at 834. Some cracking noted at blocks. They are not strapped according to current code. Location: 834 Front Task: Strap/Owner disclosure PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Floors Condition: Damage Significant cracking noted at balcony of 834. This is an issue because water may have penetrated into the wood sub floor below. Advise making corrections Implication(s): Weakened structure | Chance of movement Location: 834 Front Balcony deck Task: Repair and make sure balcony is water tight PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Steps and landings Condition: Some splitting noted at exterior steps leading to unit at 834. Repair where needed and check the termite report for dry rot issues. Location: Exterior steps at 834 Task: Repair where needed LANDSCAPING \ Lot grading Condition: We advise regrading where needed to assure all water drains away from the home foundation. No subsurface drains were noted on the property. The rear of 834 has drainage issues as does the rear patio areas behind 832 A & B. Water needs to be led away from the foundation/ crawlspace whenever possible. Location: Behind 834 and back patio area Task: Consult with drainage specialist/landscaper LANDSCAPING \ Driveway Condition: Asphalt noted cracked throughout driveway. Location: Driveway Task: Repair when needed Providing great home inspections for every client every time Page 2 of 38 Report No. 1197 SUMMARY 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR LANDSCAPING \ Walkway Condition: Stress/settling cracks noted. LANDSCAPING \ General Condition: Extensive vegetation and overgrowth noted. This can promote moisture damage and wood deterioration to the siding and structure that is not always visible to the inspector. We advise trimming/removing vegetation to prevent damage to the home. This was a limited review of this area. Damage/deterioration can only be viewed after removal of vegetation/overgrowth. Location: At rear of property Task: Cut back vegetation LANDSCAPING \ Fence Condition: Fence damage noted on property. All wood fences will have to be maintained on an ongoing basis. When a board rots, splits, or shows general deterioration, replacement will be necessary. Keep all wood fence boards out of the soil to ensure the longest life possible for your fences. Structure General There appears to be an addition to the original structure. We are unable to determine if permits were issued at the time of construction. We advise obtaining this information prior to the close of escrow. FOUNDATIONS \ Foundation Condition: The original foundation configuration is pier and post with a concrete stem wall. A very limited view from the crawl space due to access height. The pier blocks and columns appear to be lined up under the main beams of the property. No obvious interior settling was noted. The stem wall showed signs of efflorescence a result of moisture penetration. Some typical erosion has occurred around the pier blocks. 834 was built in 1977 with a slab foundation and appears in serviceable condition. If more information is required it would be necessary to consult with a structural engineer. Location: Foundation of two buildings Task: Information Condition: The crawlspace shows evidence of seasonal moisture penetration (water stains and efflorescence). It should be understood that it is impossible to predict the severity or frequency of moisture penetration on a one-time visit to a home. Virtually all crawlspaces exhibit signs of moisture penetration and most will have water intrusion at some point in time. The visible evidence is not considered unusual for a home of this age, construction and location. Further monitoring of the foundations will be needed to determine what improvements, if any, will be required. Water intrusion in the crawlspace rarely affects the structural integrity of a home. The vast majority of crawlspace leakage problems are the result of insufficient control of storm water at the surface. The ground around the home should be sloped to encourage water to flow away from the foundations. Gutters and downspouts should act to collect roof water and drain the water at least five feet from the foundation, or into a functional storm sewer. Downspouts that are clogged or broken below grade level, or that discharge too close to the foundation, are the most common source of crawlspace leakage. Please refer to the Roofing and Exterior sections of the report for more information. Providing great home inspections for every client every time Page 3 of 38 Report No. 1197 SUMMARY 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR ROOF FRAMING \ Sheathing Condition: Water stains 832A attic access Implication(s): Material deterioration Electrical General The electrical system for the property appears adequate. There is a combination of grounded and ungrounded outlets. Some GFCI outlets noted. During the renovation of the property it would be wise to have a licensed electrician sweep through the entire property and update all interior and exterior wiring. Location: Throughout property Task: Update when possible. DISTRIBUTION SYSTEM \ Outlets (receptacles) Condition: A GFCI is a low cost electrical device/outlet that protects the user of an electrical appliance from shock around water sources, such as the kitchen, bathrooms, garage, laundry and the exterior. The GFCI device turns off voltage immediately if they detect an imbalance between the current flowing in the live and neutral conductors. We strongly encourage you to upgrade all "wet area" receptacles/circuits; including laundry or utility sinks, with GFCI protection device(s) in order to enhance personal safety. Heating General See individual units for information and repairs needed. Information provided on Interior tab at top of this report. CHIMNEY AND VENT \ Masonry chimney Condition: Creosote build-up noted at chimney. We advise obtaining a professional cleaning. CHIMNEY AND VENT \ Masonry chimney cap Condition: Spark Arrester: We advise installing a spark arrester as a safety upgrade. Cooling & Heat Pump General See individual units for information and repairs needed. Information provided on Interior tab at top of this report. Providing great home inspections for every client every time Page 4 of 38 Report No. 1197 SUMMARY 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Plumbing General See individual units for information and repairs needed. Information provided on Interior tab at top of this report. Interior General Unit 834: Major Systems: Heating- Electric Newtone heaters. (not operative) AC-Window unit Water PressureAdequate Water heater: 40 gallon at rear of building Electrical: Adequate- Grounded and ungrounded outlets WHAT NEEDS TO BE DONE: 1) Repair electric heaters or provide another source of heat in Living room and bedroom 2) Clean up AC window installation 3) Provide acceptable door for Water heater cabinet (Screwed shut at time of inspection) 4) Provide discharge line for water heater 5) Provide seismic straps to code 6) Rebuild deck when changing heater or replace with Tankless 6) Provide working smoke detectors to living room and bedroom 7) Provide Carbon monoxide detector 8) Patch hole in wall in living room. 9) Patch ceiling hole in acoustic ceiling in living room. 10) Improve window installation if possible 11) Provide end caps for Formica countertop in kitchen 12) Provide GFI outlet in kitchen 13) Tighten faucet at kitchen sink 14) Patch damaged wall base at bathroom 15) Repair shower faucet. Stop on stem is not working 16) Sink is draining slowly. Clean out 17) Vanity is not secured to wall. Secure) Door to bedroom sticks at frame 19) Provide new mirrored doors to reach in closet. Cracked and torqued. 20) Close hole at top of electrical box 21) Patch crack where water heater cabinet was added 22) Replace outlet on Balcony with weatherproof outlet (GFI) Unit 832 This unit is in fair condition. Major systems: Wall unit heating two sides. AC provided by window unit. Tenant claims not enough capacity. Water pressure adequate. Water heater is a 1998 unit that will need to be replaced in the near future. Electrical system is serviceable with both grounded and ungrounded outlets. Carbon monoxide detector present. WHAT NEEDS TO BE DONE: 1) Floors need refinishing 2) Provide smoke detectors in both hall and bedrooms 3) Repair hole at front wall of living room 4) Fix or discard outlet at right of AC window unit 5) Clean mildew from both ceiling and window area of bathroom 6) Provide an electrical GFCI outlet in bathroom. 7) Seal tub spout at wall 8) Caulk all around Tub area 9) Tighten shower faucet to stop leak 10) Installation of vinyl window poorly done. Correct where possible 11) Provide closet doors at rear bedroom 12) Prior to the close of Escrow have SDGE light wall heater and check for safety Location: Unit 832 General Unit 832 B. This unit is in poor condition. Major systems: Heating: Electric unit with blower not securely mounted to wall. AC window unit in bedroom. Water pressure is adequate Electric water heater in cupboard in kitchen. Electrical system adequate. All electric unit. Both grounded and ungrounded outlets. Uneven wall/ ceiling appearance in living room. Unable to determine the cause. (See photo) WHAT NEEDS TO BE DONE: 1) Carpet is worn-Replace 2) Provide adequate heating sources in both Living room and bedroom 3) The unit is infested with roaches and termites. Rodent droppings noted. Consult with pest control specialist. 4) Provide smoke detectors in living room and Hall 4) Install cover plates on all outlets. (Safety issue) 5) Fix torn screen at living room window 6) Replace light cover in kitchen (missing) 7) Provide dead bolt for back door in kitchen 8) Back porch light inoperable or bulb missing 9) Stove appears in very poor condition - clean or replace. Oven light is not working) Clean mildew stains in bathroom 11) Provide GFCI outlet in bathroom 11) Repair or replace cartridge at shower faucet. 12) Tighten shower head to stop leaking 13) Snake drain at tub. It is very slow and backs up 14) Replace mirrored glass Providing great home inspections for every client every time Page 5 of 38 Report No. 1197 SUMMARY 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR door to reach-in at bedroom. Magic marker writing all over them Unit 832A: Major systems: Heating, wall unit was activated. AC: Front window installation Water pressure: Adequate Electrical Service: Adequate both grounded and ungrounded outlets WHAT NEEDS TO BE DONE: 1) Clean up very poor AC window unit installation (Remove plywood and Styrofoam and secure unit properly) 2) Provide discharge line for water heater 3) Provide seismic straps to code 4) Repair bottom deck of water heater closet or replace with tankless 5) Provide working smoke detectors in hall and bedrooms 6) Provide carbon monoxide detector in living room 7) Call Chimney sweep to address excess creosote issue with fireplace 8) Provide spark screen for fireplace 9) Provide spark arrester for Chimney 10) Investigate and repair floor cracking around fireplace hearth. 11) Provide light panel for kitchen light 12) Rehang back kitchen door to better fit in opening. 13)Provide end caps for Formica countertops 14) Reposition outlet at countertop 15) Provide outside light (missing) 16) Investigate noisy garbage disposal unit. 17) Secure outlet above microwave 18) Repair light on microwave 19) Clean mildew in bathroom 20) Seal tub spout at wall 21) Re-caulk around all bathtub edges 22) Secure inside shower enclosure door 23) Tighten shower head to stop leak 24) Provide cover plates for all outlets in unit 25) Repair mirror doors that are off track in front bedroom 26) Repair damaged door in front bedroom (cracked) 27) Note wall patching in rear bedroom APPLIANCES \ Dryer Condition: Dryer must be vented to exterior of the home. We advise making necessary corrections. This concludes the Summary section. The remainder of the report describes each of the home's systems and also details any recommendations we have for improvements. Limitations that restricted our inspection are included as well. The suggested time frames for completing recommendations are based on the limited information available during a pre-purchase home inspection. These may have to be adjusted based on the findings of specialists. THIS REPORT IS NOT A SUBSTITUTE FOR ANY DISCLOSURES THAT MAY BE REQUIRED BY AGENTS OR SELLERS, NOR IS IT A SUBSTITUTE FOR THE REAL ESTATE TRANSFEREE DISCLOSURE STATEMENT. PLEASE CONSULT WITH YOUR AGENT TO IDENTIFY WHICH PARTIES ARE RESPONSIBLE FOR DISCLOSING THOSE ASPECTS OF THIS TRANSACTION THAT WOULD BE OF IMPORTANCE TO YOU. Home Improvement - ballpark costs Providing great home inspections for every client every time Page 6 of 38 Report No. 1197 ROOFING 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Description Sloped roofing material: Flat roofing material: Composition shingles Built-up Recommendations General 1. The roof has a wavy appearance to it at the mid section. There is also a blue tarp covering a part of the flat room near the Satellite antenna. The tarp was covered with bricks to keep it down. The comp shingles appear in serviceable condition with very little granule loss and all ridge tiles in place. The flat roof is older with noticeable patches. All debris must be removed from gutters, damage repaired, and extensions should be provided for downspouts to lead water away from the crawl space. I would advise asking a disclosure by the seller regarding the tarp on the roof. Secondly, I would advise consulting with a contractor to check out both the waviness of the roof as well as the angle on flat roof at 834 to insure that water will not pond on top and seep into the apartment below. Location: Roof Task: Further evaluation needed by a roofing contractor 1. Wavy roof 2. Metal corrugated roof not watertight Providing great home inspections for every client every time Page 7 of 38 Report No. 1197 ROOFING 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR 3. Patch at flat roof 4. Older flat room 5. Water standing at gutter 6. Patching at Chimney cap Providing great home inspections for every client every time Page 8 of 38 Report No. 1197 ROOFING 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION 7. Flashing at chimney suspect 8. Debris in gutter 9. Tarp on flat roof 10. Gutter damaged at 834 Providing great home inspections for every client every time PLUMBING INTERIOR Page 9 of 38 Report No. 1197 ROOFING 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR 11. Excess debris on roof at 834 Limitations General: This is a "visual" inspection only. No certification, warranty, or guarantee is given as to the watertight integrity of the roof. Inspectors cannot determine watertight integrity of the roofs by a visual inspection. If such an inspection or certification of the roof is desired, we advise client contact a licensed roofer. Inspection performed: By walking on roof Providing great home inspections for every client every time Page 10 of 38 Report No. 1197 EXTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Description General: With the exception of town homes, condominiums, and residences that are part of a planned urban development, or PUD, we evaluate the following exterior features: driveways, walkways, fences, gates, handrails, guard-rails, yard walls, carports, patio covers, decks, building walls, fascia and trim, balconies, doors, windows, lights, and outlets. However, we do not evaluate any detached structures, such as storage sheds and stables, and we do not water test or evaluate subterranean drainage systems or any mechanical or remotely controlled components, such as driveway gates. Also, we do not evaluate landscape components, such as trees, shrubs, fountains, ponds, statuary, pottery, fire pits, patio fans, heat lamps, and decorative or low-voltage lighting. In addition, we do not comment on coatings or cosmetic deficiencies and the wear and tear associated with the passage of time, which would be apparent to the average person. Gutter & downspout material: Gutter & downspout type: Metal Eave mounted Gutter & downspout discharge: Lot slope: Flat Wall surfaces : Stucco Soffit and fascia: Retaining wall: Wood Not applicable Driveway: Asphalt Walkway: Concrete Porch: Concrete Exterior steps: Balcony: Patio: Fence: Above grade Concrete Wood Concrete Wood Chain link Recommendations General 2. We advise referring to structural pest inspection report. Please refer to pest control report for all issues concerning dry rot and termite damage on property. Providing great home inspections for every client every time Page 11 of 38 Report No. 1197 EXTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Click on image to enlarge. ROOF DRAINAGE \ Gutters 3. Condition: Loose or damaged Front gutter at 834 is loose and damaged. It is torn in the rear section. Implication(s): Chance of water damage to contents, finishes and/or structure Location: Front gutter 834 Task: Repair or replace ROOF DRAINAGE \ Downspouts 4. Condition: Should discharge 6ft. from building We advise adding an extension to lead water away from the home Implication(s): Chance of water damage to contents, finishes and/or structure Providing great home inspections for every client every time Page 12 of 38 Report No. 1197 EXTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Click on image to enlarge. Click on image to enlarge. EXTERIOR http://advantagehomeinspection.net WALLS \ Soffits and fascia 5. Condition: Damage Some wood splitting noted at Fascia. Implication(s): Cosmetic defects | Chance of water damage to contents, finishes and/or structure Providing great home inspections for every client every time Page 13 of 38 Report No. 1197 EXTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Click on image to enlarge. EXTERIOR http://advantagehomeinspection.net WALLS \ Stucco and EIFS 6. Condition: Moisture penetration noted at exterior stucco. The stucco is flaking away and crumbling at various locations on property. A trowled area at the front of the property has been left unfinished between the two new vinyl window. Large patches have been noted. Moisture penetration and flaking noted at the rear wall of 834 addition. It would be wise to consult with a stucco specialist to make corrections before further deterioration occurs. Location: Exterior stucco Task: Repair where needed/Consult specialist 12. Stucco crumbling 13. Large patches to stucco Providing great home inspections for every client every time Page 14 of 38 Report No. 1197 EXTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO 14. More crumbling EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR 15. Unfinished area EXTERIOR GLASS \ Storms and screens 7. Condition: Make sure all window and door screens are present and in serviceable condition. This is considered part of normal home maintenance. PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Columns 8. Condition: Support columns were added to support balcony at 834. Some cracking noted at blocks. They are not strapped according to current code. Location: 834 Front Task: Strap/Owner disclosure PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Floors 9. Condition: Damage Significant cracking noted at balcony of 834. This is an issue because water may have penetrated into the wood sub floor below. Advise making corrections Implication(s): Weakened structure | Chance of movement Location: 834 Front Balcony deck Task: Repair and make sure balcony is water tight Providing great home inspections for every client every time Page 15 of 38 Report No. 1197 EXTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR 16. Cracked at top of stairs PORCHES, DECKS, STEPS, PATIOS AND BALCONIES \ Steps and landings 10. Condition: Some splitting noted at exterior steps leading to unit at 834. Repair where needed and check the termite report for dry rot issues. Location: Exterior steps at 834 Task: Repair where needed LANDSCAPING \ Lot grading 11. Condition: We advise regrading where needed to assure all water drains away from the home foundation. No subsurface drains were noted on the property. The rear of 834 has drainage issues as does the rear patio areas behind 832 A & B. Water needs to be led away from the foundation/ crawlspace whenever possible. Location: Behind 834 and back patio area Task: Consult with drainage specialist/landscaper 17. Pooling issues 18. Curb repair noted to repel water Page 16 of 38 Providing great home inspections for every client every time Report No. 1197 EXTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR 19. Water draining towards crawlspace LANDSCAPING \ Driveway 12. Condition: Asphalt noted cracked throughout driveway. Location: Driveway Task: Repair when needed 20. Asphalt cracked Providing great home inspections for every client every time Page 17 of 38 Report No. 1197 EXTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR LANDSCAPING \ Walkway 13. Condition: Stress/settling cracks noted. LANDSCAPING \ General 14. Condition: Extensive vegetation and overgrowth noted. This can promote moisture damage and wood deterioration to the siding and structure that is not always visible to the inspector. We advise trimming/removing vegetation to prevent damage to the home. This was a limited review of this area. Damage/deterioration can only be viewed after removal of vegetation/overgrowth. Location: At rear of property Task: Cut back vegetation LANDSCAPING \ Fence 15. Condition: Fence damage noted on property. All wood fences will have to be maintained on an ongoing basis. When a board rots, splits, or shows general deterioration, replacement will be necessary. Keep all wood fence boards out of the soil to ensure the longest life possible for your fences. 21. Fence damage Providing great home inspections for every client every time Page 18 of 38 Report No. 1197 STRUCTURE 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Description General: All structures are dependent on the soil beneath them for support, but soils are not uniform. Some that might appear to be firm and solid can liquefy and become unstable during seismic activity. Also, there are soils that can expand to twice their volume with the influx of water and move structures with relative ease, raising and lowering them and fracturing slabs and other hard surfaces. In fact, expansive soils have accounted for more structural damage than most natural disasters. Regardless, foundations are not uniform, and conform to the structural standard of the year in which they were built. In accordance with our standards of practice, we identify foundation types and look for any evidence of structural deficiencies where visible. However, cracks or deteriorated surfaces in foundations are quite common. In fact, it would be rare to find a slab foundation that did not include some cracks concealed beneath the carpeting and padding. Fortunately, most of these cracks are related to the curing process or to common settling, including some wide ones called cold-joint separations that typically contour the footings, but others can be more structurally significant and reveal the presence of expansive soils that can predicate more or less continual movement. We will certainly alert you to any suspicious cracks if they are clearly visible. Configuration: This residence has a slab foundation. Such foundations vary considerably from older ones that have no moisture barrier under them and no reinforcing steel within them to newer ones that have both. Our inspection of slab foundations conforms to industry standards, which is that of a generalist and not a specialist. We check the visible portion of the stem walls on the outside for any evidence of significant cracks or structural deformation, but we do not move furniture or lift carpeting and padding to look for cracks or moisture penetration, and we do not use any of the specialized devices that are used to establish relative elevations and confirm differential movement. Significantly, many slabs are built or move out of level, but the average person may not become aware of this until there is a difference of more than one inch in twenty feet, which most authorities regard as being tolerable. Many slabs are found to contain cracks when the carpet and padding are removed, including some that contour the edge and can be quite wide. They typically result from shrinkage and usually have little structural significance. However, there is no absolute standard for evaluating cracks, and those that are less than 1/4" and which exhibit no significant vertical or horizontal displacement are generally not regarded as being significant. Although they typically do result from common shrinkage, they can also be caused by a deficient mixture of concrete, deterioration through time, seismic activity, adverse soil conditions, and poor drainage, and if they are not sealed they can allow moisture to enter a residence, and particularly if the residence is surcharged by a hill or even a slope, or if downspouts discharge adjacent to the slab. However, in the absence of any major defects, we may not recommend that you consult with a foundation contractor, a structural engineer, or a geologist, but this should not deter you from seeking the opinion of any such expert, and we would be happy to refer one. Pier and Post Construction Providing great home inspections for every client every time Page 19 of 38 Report No. 1197 STRUCTURE 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO Configuration: EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Slab-on-grade Foundation material: Floor construction: Poured concrete stem wall Joists Exterior wall construction: Roof and ceiling framing: Concrete Wood frame Rafters/roof joists Plywood sheathing Recommendations General 16. There appears to be an addition to the original structure. We are unable to determine if permits were issued at the time of construction. We advise obtaining this information prior to the close of escrow. FOUNDATIONS \ Foundation 17. Condition: The original foundation configuration is pier and post with a concrete stem wall. A very limited view from the crawl space due to access height. The pier blocks and columns appear to be lined up under the main beams of the property. No obvious interior settling was noted. The stem wall showed signs of efflorescence a result of moisture penetration. Some typical erosion has occurred around the pier blocks. 834 was built in 1977 with a slab foundation and appears in serviceable condition. If more information is required it would be necessary to consult with a structural engineer. Location: Foundation of two buildings Task: Information 18. Condition: The crawlspace shows evidence of seasonal moisture penetration (water stains and efflorescence). It should be understood that it is impossible to predict the severity or frequency of moisture penetration on a one-time visit to a home. Virtually all crawlspaces exhibit signs of moisture penetration and most will have water intrusion at some point in time. The visible evidence is not considered unusual for a home of this age, construction and location. Further monitoring of the foundations will be needed to determine what improvements, if any, will be required. Water intrusion in the crawlspace rarely affects the structural integrity of a home. The vast majority of crawlspace leakage problems are the result of insufficient control of storm water at the surface. The ground around the home should be sloped to encourage water to flow away from the foundations. Gutters and downspouts should act to collect roof water and drain the water at least five feet from the foundation, or into a functional storm sewer. Downspouts that are clogged or broken below grade level, or that discharge too close to the foundation, are the most common source of crawlspace leakage. Please refer to the Roofing and Exterior sections of the report for more information. ROOF FRAMING \ Sheathing 19. Condition: Water stains 832A attic access Implication(s): Material deterioration Providing great home inspections for every client every time Page 20 of 38 Report No. 1197 STRUCTURE 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR 22. Water stains noted Providing great home inspections for every client every time Page 21 of 38 Report No. 1197 ELECTRICAL 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Description Service entrance cable and location: Service size: Overhead aluminum 100 Amps (240 Volts) Main disconnect/service box rating: 125 Amps Main disconnect/service box type and location: System grounding material and type: Distribution panel rating: Breakers -exterior wall Not visible 125 Amps Distribution panel type and location: Auxiliary panel (subpanel) rating: Breakers - exterior wall Unable to determine Distribution wire material and type: Copper - non-metallic sheathed Type and number of outlets (receptacles): Grounded and ungrounded - typical Circuit interrupters: Ground Fault (GFCI) & Arc Fault (AFCI): Smoke detectors: Aluminum - non-metallic sheathed Some noted Battery Operated Recommendations General 20. The electrical system for the property appears adequate. There is a combination of grounded and ungrounded outlets. Some GFCI outlets noted. During the renovation of the property it would be wise to have a licensed electrician sweep through the entire property and update all interior and exterior wiring. Location: Throughout property Task: Update when possible. DISTRIBUTION SYSTEM \ Outlets (receptacles) 21. Condition: A GFCI is a low cost electrical device/outlet that protects the user of an electrical appliance from shock around water sources, such as the kitchen, bathrooms, garage, laundry and the exterior. The GFCI device turns off voltage immediately if they detect an imbalance between the current flowing in the live and neutral conductors. We strongly encourage you to upgrade all "wet area" receptacles/circuits; including laundry or utility sinks, with GFCI protection device(s) in order to enhance personal safety. Providing great home inspections for every client every time Page 22 of 38 Report No. 1197 HEATING 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Recommendations General 22. See individual units for information and repairs needed. Information provided on Interior tab at top of this report. CHIMNEY AND VENT \ Masonry chimney 23. Condition: Creosote build-up noted at chimney. We advise obtaining a professional cleaning. CHIMNEY AND VENT \ Masonry chimney cap 24. Condition: Spark Arrester: We advise installing a spark arrester as a safety upgrade. Providing great home inspections for every client every time Page 23 of 38 Report No. 1197 COOLING & HEAT PUMP 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Description General: Window/wall mounted a/c unit noted. We are unable to determine if unit is sufficient to reduce air temperature in entire area. Recommendations General 25. See individual units for information and repairs needed. Information provided on Interior tab at top of this report. Providing great home inspections for every client every time Page 24 of 38 Report No. 1197 INSULATION AND VENTILATION 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Description General: Attic location is at: Note: 832 A Attic/roof insulation material: blown 23. Blown Attic/roof insulation amount/value: Attic/roof ventilation: Roof and soffit vents Attic/roof air/vapor barrier: Crawlspace ventilation: 6-8" thick None found Wall Vents Providing great home inspections for every client every time Page 25 of 38 Report No. 1197 PLUMBING 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Description General: Plumbing systems have common components, but they are not uniform. In addition to fixtures, these components include gas pipes, water pipes, pressure regulators, pressure relief valves, shut-off valves, drain and vent pipes, and water-heating devices, some of which we do not test if they are not in daily use. The best and most dependable water pipes are copper, because they are not subject to the build-up of minerals that bond within galvanized pipes, and gradually restrict their inner diameter and reduce water volume. Water softeners can remove most of these minerals, but not once they are bonded within the pipes, for which there would be no remedy other than a re-pipe. The water pressure within pipes is commonly confused with water volume, but whereas high water volume is good high water pressure is not. In fact, whenever the street pressure exceeds eighty pounds per square inch a regulator is recommended, which typically comes factory preset between forty-five and sixty-five pounds per square inch. However, regardless of the pressure, leaks will occur in any system, and particularly in one with older galvanized pipes, or one in which the regulator fails and high pressure begins to stress the washers and diaphragms within the various components. Waste and drainpipes pipes are equally varied, and range from modern ABS ones [acrylonitrile butadiene styrene] to older ones made of cast-iron, galvanized steel, clay, and even a cardboard-like material that is coated with tar. The condition of these pipes is usually directly related to their age. Older ones are subject to damage through decay and root movement, whereas the more modern ABS ones are virtually impervious to damage, although some rare batches have been alleged to be defective. However, inasmuch as significant portions of drainpipes are concealed, we can only infer their condition by observing the draw at drains. Nonetheless, blockages will occur in the life of any system, but blockages in drainpipes, and particularly in main drainpipes, can be expensive to repair. If the buyer is concerned we recommend having them video-scanned. Water supply source: Public Service piping into building: Supply piping in building: Copper Copper Main water shut off valve at the: Galvanized steel Galvanized steel Front of property Water flow and pressure: Note: 60 PSI reading is Water flow and pressure: Note: None noted Pressure regulator location: Providing great home inspections for every client every time Page 26 of 38 Report No. 1197 PLUMBING 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR Water flow and pressure: Functional Water heater fuel/energy source: Gas ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Typical for neighborhood Electric Water heater type: Note: At rear Water heater located at: Water heater type: There are a wide variety of residential water heaters that range in capacity from fifteen to one hundred gallons. They can be expected to last at least as long as their warranty, or from five to eight years, but they will generally last longer. However, few of them last longer than fifteen or twenty years and many eventually leak. So it is always wise to have them installed over a drain pan plumbed to the exterior. Also, it is prudent to flush them annually to remove minerals that include the calcium chloride bi-product of many water softening systems. The water temperature should be set at a minimum of 110 degrees fahrenheit to kill microbes and a maximum of 140 degrees to prevent scalding. Also, water heaters can be dangerous if they are not seismically secured and equipped with either a pressure/temperature relief valve and discharge pipe plumbed to the exterior, or a Watts 210 gas shut-off valve. Waste disposal system: Waste piping in building: Gas piping: Note: Rear Public ABS plastic Cast Iron Gas meter located at: Recommendations General 26. See individual units for information and repairs needed. Information provided on Interior tab at top of this report. Limitations Fixtures not tested/not in service: Since main shut-off valves are operated infrequently, it is not unusual for them to become frozen over time. They often leak or break when operated after a period of inactivity. For this reason main shut-off valves are not tested during a home inspection. We suggest caution when operating shut-offs that have not been turned for a long period of time. All shut-off valves and angle stops should be turned regularly to ensure free movement in case of emergency. Providing great home inspections for every client every time Page 27 of 38 Report No. 1197 INTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR http://advantagehomeinspection.net ELECTRICAL HEATING COOLING INSULATION PLUMBING INTERIOR Description General: This unit was tenant occupied a the time of inspection. Conditions noted at this time may change before the buyer takes possession of the home. Major floor finishes: Wood Major floor finishes: Carpet Tile Major wall and ceiling finishes: Drywall Major wall and ceiling finishes: Plaster/drywall Windows: Glazing: Doors: Vinyl Single Double Inspected Evidence of crawlspace leakage: Oven fuel: Range fuel: Electricity Gas Electricity Laundry facilities: Efflorescence Gas Washer Hot/cold water supply Dryer 120-Volt outlet Waste standpipe Gas piping Recommendations General 27. Unit 834: Major Systems: Heating- Electric Newtone heaters. (not operative) AC-Window unit Water PressureAdequate Water heater: 40 gallon at rear of building Electrical: Adequate- Grounded and ungrounded outlets WHAT NEEDS TO BE DONE: 1) Repair electric heaters or provide another source of heat in Living room and bedroom 2) Clean up AC window installation 3) Provide acceptable door for Water heater cabinet (Screwed shut at time of inspection) 4) Provide discharge line for water heater 5) Provide seismic straps to code 6) Rebuild deck when changing heater or replace with Tankless 6) Provide working smoke detectors to living room and bedroom 7) Provide Carbon monoxide detector 8) Patch hole in wall in living room. 9) Patch ceiling hole in acoustic ceiling in living room. 10) Improve window installation if possible 11) Provide end caps for Formica countertop in kitchen 12) Provide GFI outlet in kitchen 13) Tighten faucet at kitchen sink 14) Patch damaged wall base at bathroom 15) Repair shower faucet. Stop on stem is not working 16) Sink is draining slowly. Clean out 17) Vanity is not secured to wall. Secure) Door to bedroom sticks at frame 19) Provide new mirrored doors to reach in closet. Cracked and torqued. 20) Close hole at top of electrical box 21) Patch crack where water heater cabinet was added 22) Replace outlet on Balcony with weatherproof outlet (GFI) Providing great home inspections for every client every time Page 28 of 38 Report No. 1197 INTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR 24. Newtone heaters not working 25. Provide working door 26. Poor AC Installation 27. Weatherproof outlet on balcony Providing great home inspections for every client every time Page 29 of 38 Report No. 1197 INTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR 28. Window pulling away from framing ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR 29. Patching needed in bathroom 30. Ceiling repair at living room 31. Cracked glass 28. Unit 832 This unit is in fair condition. Major systems: Wall unit heating two sides. AC provided by window unit. Tenant claims not enough capacity. Water pressure adequate. Water heater is a 1998 unit that will need to be replaced in the near future. Electrical system is serviceable with both grounded and ungrounded outlets. Carbon monoxide detector present. WHAT NEEDS TO BE DONE: 1) Floors need refinishing 2) Provide smoke detectors in both hall and bedrooms 3) Repair hole at front wall of living room 4) Fix or discard outlet at right of AC window unit 5) Clean mildew from both ceiling and window area of bathroom 6) Provide an electrical GFCI outlet in bathroom. 7) Seal tub spout at wall 8) Caulk all around Tub area 9) Tighten shower faucet to stop leak 10) Installation of vinyl window poorly done. Correct where possible 11) Provide closet doors at rear bedroom 12) Prior to the close of Escrow have SDGE light wall heater and check for safety Providing great home inspections for every client every time Page 30 of 38 Report No. 1197 INTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Location: Unit 832 General 32. Clean mildew at window 33. Ceiling mildew 34. Unit 832 29. Unit 832 B. This unit is in poor condition. Major systems: Heating: Electric unit with blower not securely mounted to wall. AC window unit in bedroom. Water pressure is adequate Electric water heater in cupboard in kitchen. Electrical system adequate. All electric unit. Both grounded and ungrounded outlets. Uneven wall/ ceiling appearance in living room. Unable to determine the cause. (See photo) WHAT NEEDS TO BE DONE: 1) Carpet is worn-Replace 2) Provide adequate heating sources in both Living room and bedroom 3) The unit is infested with roaches and termites. Rodent droppings noted. Consult with pest control specialist. 4) Provide smoke detectors in living room and Hall 4) Install cover plates on all outlets. (Safety issue) 5) Fix torn screen at living room window 6) Replace light cover in kitchen (missing) 7) Provide dead bolt for back door in kitchen 8) Back porch light inoperable or bulb missing 9) Stove appears in very poor condition - clean or replace. Oven light is not working) Clean mildew stains in bathroom 11) Provide GFCI outlet in bathroom 11) Repair or replace cartridge at shower faucet. 12) Tighten shower head to stop leaking 13) Snake drain at tub. It is very slow and backs up 14) Replace mirrored glass Providing great home inspections for every client every time Page 31 of 38 Report No. 1197 INTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR door to reach-in at bedroom. Magic marker writing all over them 35. 832B 36. Slow drain 37. Leak at shower head 38. Inadequate electric heater Providing great home inspections for every client every time Page 32 of 38 Report No. 1197 INTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR 40. Uneven wall profile 39. Marking on mirrored doors 30. Unit 832A: Major systems: Heating, wall unit was activated. AC: Front window installation Water pressure: Adequate Electrical Service: Adequate both grounded and ungrounded outlets WHAT NEEDS TO BE DONE: 1) Clean up very poor AC window unit installation (Remove plywood and Styrofoam and secure unit properly) 2) Provide discharge line for water heater 3) Provide seismic straps to code 4) Repair bottom deck of water heater closet or replace with tankless 5) Provide working smoke detectors in hall and bedrooms 6) Provide carbon monoxide detector in living room 7) Call Chimney sweep to address excess creosote issue with fireplace 8) Provide spark screen for fireplace 9) Provide spark arrester for Chimney 10) Investigate and repair floor cracking around fireplace hearth. 11) Provide light panel for kitchen light 12) Rehang back kitchen door to better fit in opening. 13)Provide end caps for Formica countertops 14) Reposition outlet at countertop 15) Provide outside light (missing) 16) Investigate noisy garbage disposal unit. 17) Secure outlet above microwave 18) Repair light on microwave 19) Clean mildew in bathroom 20) Seal tub spout at wall 21) Re-caulk around all bathtub edges 22) Secure inside shower enclosure door 23) Tighten shower head to stop leak 24) Provide cover plates for all outlets in unit 25) Repair mirror doors that are off track in front bedroom 26) Repair damaged door in front bedroom (cracked) 27) Note wall patching in rear bedroom Providing great home inspections for every client every time Page 33 of 38 Report No. 1197 INTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR 42. Shower head leaking 41. Wall patched 43. Deck rotting 44. 432 A Providing great home inspections for every client every time Page 34 of 38 Report No. 1197 INTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING 45. Floor damage 46. Move outlet 47. Patching at kitchen 48. Secure outlet INSULATION Providing great home inspections for every client every time PLUMBING INTERIOR Page 35 of 38 Report No. 1197 INTERIOR 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR 50. Spark screen needed 49. Plywood at window AC unit 51. light panel missing 52. No discharge line/ straps APPLIANCES \ Dryer 31. Condition: Dryer must be vented to exterior of the home. We advise making necessary corrections. Providing great home inspections for every client every time Page 36 of 38 Report No. 1197 GARAGE 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Description Parking Structure Type: Parking area converted to other use Providing great home inspections for every client every time Page 37 of 38 Report No. 1197 SITE INFO 1220 Sample report St, Vista, CA October 12, 2012 SUMMARY ROOFING STRUCTURE GARAGE SITE INFO EXTERIOR ELECTRICAL http://advantagehomeinspection.net HEATING COOLING INSULATION PLUMBING INTERIOR Description Weather: Cloudy Attendees: Buyer Seller Buyer’s Agent Access to home provided by: Occupancy: Utilities: Seller The home was occupied at the time of the inspection. All utilities were on during the inspection. Approximate age of home: 54 years Approximate date of construction: Building type: 1977 1958 Apartment Number of stories: One Below grade area: Crawlspace Two Garage, carport and outbuildings: Area: The home was furnished during the inspection. Slab-on-grade At rear and front of building Suburb END OF REPORT Providing great home inspections for every client every time Page 38 of 38
© Copyright 2024