Multiple Interval & File Data Logging Add-on software package for DAQ32Plus/DAQLOGGER Multi Sample Data Logging Software AddMulti for Windows98 / Me / NT 4.0 / 2000 / XP ● Runs as a simple add-on to existing DAQ32Plus/DAQLogger software ● 50 measurement groups with 32 channels per group ● Each group has individual measurement interval ● Each group logs to an independent data file on PC ● Simultaneous multi-group start or single group start ● Logging start/stop can be controlled be a wide range of triggers settings www.yokogawa.com/tm/ ... and subscribe to “Newswave,” our free e-mail newsletter Bulletin 04M06D02-00E AddMulti is a special add-on so groups and acquisition conditi group. As many as 32 channels Group Launcher Group Launcher is used to set data acquisition conditions for individual groups, and to start/stop data logging. In addition, Group Launcher displays group names and statuses. The green flags for individual groups are symbols to start batch logging. Highlighted groups can be started individually. Overview Overview enables real-time monitoring of the operating statuses of individual groups through Signal Monitor, Data File Storage Monitor, and Operation Status Detailed Display Monitor. Signal Monitor Status in which data acquisition start conditions are monitored Data logging performed when data acquisition conditions are met Stopped Error (e.g., setting error) Data File Storage Monitor (↑ ) Enables real-time monitoring of the data file creation status of groups specified in the group list (on right). Operation Status Detailed Display Monitor (→) Enables real-time monitoring of each group's data acquisition status, measurement intervals, start/stop times, number of data records, etc. Data View Data View lets you use functions optimized for data analysis and processing, such as redisplaying saved data files, reading data using the cursor function, and computing data over cursor intervals. Data files can be converted to Excel, Lotus, and ASCII formats. Graphic Monitors Multi-interval, Multi-file You can create a customized real-time data monitoring environment by specifying the layout of information displays (e.g., trends, digital, level meter, analog meter, thermometer, and temperature distribution), as well as various graphic monitors like Group Launcher and Overview. With AddMulti, you can create measurement groups to separately set measurement channels assigned to measurement points involved in multiple measurements. Measurement subject Data acquisition device Measurement group Device A Measurement Gr. No. 1 Device B Measurement Gr. No. 2 Device C Measurement Gr. No. 3 Data acquisition conditions for each group Acquisition start Acquisition end Acquisition Acquisition Acquisition Acquisition start end start end Acquisition start Acquisition end Time Device n Measurement Gr. No. n Start End Start End Start End DARWIN DAQ32Plus DAQLOGGER oftware package for DARWIN DAQ32Plus and DAQLOGGER. Data acquisition channels are split among as many as 50 measurement ons are set to enable independent data acquisition for individual groups. Data files are stored in separate data directories for each s can be set for an individual measurement group. Data Acquisition Condition Setting Recording Rate Setting Group names, channel assignments, recording rates, and other parameters can be set for each group on this screen. Measurement data acquired from a DARWIN DAQ32Plus or DAQLOGGER monitor server can be logged at a specified recording rate. The recording interval is the product of the scanning interval (set in DAQ32Plus or DAQLOGGER) and the recording rate (parameter set in Acquisition Conditions Setting screen shown above). When a recording rate is set for each group, data can be logged asynchronously for individual groups. Connected host name: Simply enter the host name of the connecting PC to connect. Port number: DAQ32Plus = 50278; DAQLOGGER = 50280 Example with recording rate set to "4" Data acquired from DARWIN DAQ32Plus or DAQLOGGER monitor server Time Scanning interval Recording interval Logging Data Trigger Filter Logging Data File Storage With this function, in cases where the logging start condition is an alarm trigger or level trigger, the trigger condition is recognized as met and logging starts/ends only when the trigger-ON status continues for a specified number of trigger checks. This function serves to prevent the trigger condition from being met accidentally due to a noise-induced change in a measured value. Data Storage Directories Example with trigger check count set to "3" Data File Sorting Logging period No logging Monitored point Time Logging interval Monitored point Start conditions: End conditions: A wide range of data acquisition start/end conditions are provided. Data logging starts as soon as the record START button is manually pressed. Data logging is performed continuously until the STOP button is manually pressed. Immediate logging start Logging end with continuous logging Logging start Logging end Logging Data files are saved separately for each group, so even large measurement data files are properly sorted when they are saved. This makes it easier to redisplay old data and to analyze data quickly. Point where end condition is monitored Point where start condition is monitored When start condition is satisfied When end condition is satisfied Data acquisition start/end conditions Immediate: Continuous: Any data storage directory can be specified for each group in the data acquisition conditions settings. A number of data directories equal to the number of set groups is automatically created under each project directory. Alarm trigger: Immediate, Timer, Alarm Trigger, Level Trigger Continuous, Timer, Alarm Trigger, Level Trigger, Data Records When recording starts, the system monitors alarm statuses in trigger standby status. Logging starts/ends when an alarm occurs/is cleared. Logging start with alarm trigger Monitoring start Trigger point Monitored alarm Logging Logging start Monitoring Logging Recording START Timer: Recording STOP When recording starts, the system monitors the data logging time in trigger standby status. Logging starts/ends when the data logging time equals/exceeds the specified time. Logging start at specified time Monitoring start Specified time Logging start Logging end at specified time Specified time Monitoring end Recording start Data trigger: Logging Level trigger: Recording end Logging end Logging Monitoring Recording end When recording starts, the system monitors measurement data in trigger standby status. Logging starts/ends when the measured data value goes over/under a specified data value. Logging with level trigger Trigger point Monitoring start Logging end Logging Trigger point Monitoring end Monitored alarm Recording start Measured data Monitored level Logging start Monitoring Logging end with alarm trigger Monitoring Logging Recording start Logging with level trigger Measured data Monitored level Trigger point Monitoring end Logging end Logging Monitoring Recording end In cases where the logging start condition is an alarm trigger or level trigger, if a number of data records is specified as the end condition, logging ends when the specified number of data records is written to the file. Multiple Interval and File Data Logging System Configuration Devices connecting to data logging software µR1000 VR100 DX100 MV100 µR1800 VR200 DX200 MV200 DA100 DC100 DR130 DR230 DR240 DAQ32Plus — — — — ✓ ✓ ✓ ✓ ✓ DAQLOGGER ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ List of Data Acquisition Device Communication Functions µR1000 VR100 DX100 MV100 µR1800 VR200 DX200 MV200 DA100 DC100 DR130 DR230 DR240 GP-IB RS-232-C RS-422-A Ethernet — — ✓ — — — ✓ — — ✓ ✓ ✓ — ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ — ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Multi-Sample Data Logging System AddMulti • Asynchronous multi-sample data logging with separate measurement intervals set for individual groups • Special add-on software package for DAQ32Plus/DAQLOGGER • Easy connection to DAQ32Plus/DAQLOGGER simply by specifying host name • Set up to 50 measurement groups (up to 32 channels per group) • Create separate data directories for each group to store data files • Simultaneous multi-group start or single-group start DARWIN DAQ32Plus • Special package for DARWIN series • High-speed data acquisition (measurement interval as short as 500 ms) • Rapid system setup with up to 300 channels • Real-time monitoring and data logging • Data file redisplay and format conversion • DDE server and automatic file conversion functions • Monitoring with various graphic tools Select the appropriate device from the data acquisition equipment group in the bottom row based on the type of recording you will be doing (i.e., PC-based, recording paper, electronic data memory). If you are using a PC-based system, also select an appropriate connection method from the list of data acquisition device communication functions (top row). Either DAQ32Plus or DAQLOGGER can be installed as data logging software on your PC, depending on the intended application. With full support for everything from data logging to settings, this software package lets you quickly set up a flexible PC-based data logging system. Connecting the AddMulti add-on software makes it easier to set up a multi-sample logging system capable of asynchronous data logging for individual groups. -C -A et 32 22 rn I--IBB S-2 S-4 he t P GGP R R E RS-232-C RS-422-A Ethernet DAQLOGGER • Multi-sample logging connection with up to 1600 channels on 32 units • Support for multiple standards (Ethernet, RS232C, RS422A) • Real-time monitoring and data logging • Data file redisplay and format conversion • DDE server and reporting functions • Event (alarm) notification by email • Send event information with attached screenshots (.png images) and data files Ethernet Industrial Recorder series Data Acquisition and Recording Windows Wide View Recorder Specifications Product name ■ AddMulti multi-sample data logging software package Model number and suffix codes Product name AddMulti Type VA700 OS Suffix code -0 Channels 1 2 Language -2 Description Multi-sample data logging software Windows 98, Me, NT4.0, 2000, and XP Up to 400 channels Up to 1600 channels English • License monitoring AddMulti connects with the monitor server where DARWIN DAQ32Plus or DAQLOGGER is installed through a peer-to-peer connection. When the Ethernet connection is established, the license numbers provided when each software product is installed are monitored. Terminals with identical license numbers cannot establish a network connection with each other. • Number of AddMulti connections to monitor server DAQ32Plus: Up to 8 connections DAQLOGGER: Up to 16 connections • Time management AddMulti operates based on the clock time acquired from the connected monitor server. Function Overview PC system requirements 400-channel model AddMulti operations have been verified for Japanese language Microsoft Windows 98, Me, NT4.0, 2000, and XP. Requires a PC with an Intel Pentium II processor running at 400 MHz or faster (Pentium III processor running at 800 MHz or faster recommended). RAM: 128 MB or more (256 MB or more recommended) 1600-channel model AddMulti operations have been verified for Japanese language Microsoft Windows 98, Me, NT4.0, 2000, and XP. Requires a PC with an Intel Pentium III processor running at 600 MHz or faster (Pentium III processor running at 800 MHz or faster recommended). RAM: 256 MB or more (512 MB or more recommended) Requirements for both models • Operating system: Microsoft Windows 98, Me, NT4.0, 2000, or XP • Hard drive: At least 100 MB of free disk space required for installation (more free space may be needed to handle large acquired-data files) • Display: SVGA display with 1024×768 pixels and 65,536-color display capability • CD-ROM drive (required for installation), mouse, keyboard, and printer • Communication port: Ethernet port recognized by operating system (required because TCP/IP connection is used for connecting to the monitor server where the data acquisition software connection is installed) Connection Methods AddMulti receives data from data acquisition software, so one of the following data acquisition software programs is required to run AddMulti. DAQ32Plus: R9.01 or higher (R10.03 or higher recommended*) DAQLOGGER: R3.01 or higher (R5.01 or higher recommended*) *: "R" refers to the release number of these software products. We recommend using most recent release of the data acquisition software in order to reduce the load during network connections and to enable high-speed communication. • Connection to monitor server AddMulti acquires data and performs multi-sample logging as a client of the monitor server where DARWIN DAQ32Plus or DAQLOGGER is installed. • Communication protocol Ethernet is the only protocol that can be used for connection to the monitor server. • Data logging methods Data logging using AddMulti is defined as a multi-sample logging method. The AddMulti data acquisition method works as follows. The channels to be used in data acquisition are split among multiple groups. Acquisition conditions are set for each group, and each group acquires data independently according to its acquisition conditions. • Group settings The only data acquired from the monitor server is the data on the channels assigned based on the individual group acquisition conditions. Up to 50 groups can be set, and up to 32 channels can be set per group. • Scanning interval The fastest scanning interval depends on the fastest sampling rate of the connected data acquisition software. The fastest sampling rate for DAQ32Plus is 0.5 second, and the fastest rate for DAQLOGGER is 1.0 second. • Recording interval The recording interval is set as an integer multiple of the monitor server's scanning interval. • Data acquisition start/end conditions Start conditions: Immediate, Timer, Alarm Trigger, Level Trigger End conditions: Immediate, Timer, Alarm Trigger, Level Trigger, Number of Data Records • Data acquisition status monitor The acquisition statuses of individual acquisition groups can be monitored using the Overview. • Data monitors Data acquired from the monitor server can be monitored in real-time by various graphic monitors. The data corresponds to the channels assigned based on the displayed AddMulti acquisition conditions. • Automatic conversion (auto-processor function) Once data is written to a data file during data acquisition, the file can be automatically converted to Excel, Lotus, or ASCII (text) format. ■ Trademarks Lotus 1-2-3 is a registered trademark of Lotus Development Corporation. Excel is a registered trademark of Microsoft corporation, the United States. Microsoft Windows 98, Me, NT4.0, 2000, and XP are registered trademarks of Microsoft Corporation, the United States. Ethernet is a registered trademark of Xerox Corporation, the United States. Other company names and product names appearing in this document are trademarks or registered trademarks of their respective companies. YOKOGAWA ELECTRIC CORPORATION Network Solutions Sales Dept./Phone: 81-422-52-6765, Fax: 81-422-52-6793 YOKOGAWA CORPORATION OF AMERICA YOKOGAWA EUROPE B.V. YOKOGAWA ENGINEERING ASIA PTE. LTD. Phone: (1)-770-253-7000, Fax: (1)-770-251-2088 Phone: (31)-33-4641806, Fax: (31)-33-4641807 Phone: (65)-2419933, Fax: (65)-2412606 Subject to change without notice. [Ed : 01/b] Copyright ©2002 Printed in Japan, 203(YG) RS-11E
© Copyright 2024