Wireless Radiator Valve Model: TRV10RF

iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:29 Stro
Wireless Radiator Valve
Model: TRV10RF
I N S TA L L E R M A N U A L
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:29 Stro
Contents of the box
Box Contents
Icons used in this manual:
Safety
Important info
Your benefit
Contents:
Box Contents
Introduction
Product Compliance and
Safety Information
Installation
User Interface
Status/LED indication
Installers notes
Warranty
TRV10RF
2x AA Batteries
Adapter
For latest PDF installation
guide please go to
www.salus-controls.com
Manual
02 TRV10RF Installer Manual
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:29 Stro
Product Compliance & Safety Information
INTRODUCTION
Thank you for purchasing the SALUS wireless radiator valve (TRV10RF). The
SALUS Wireless Controlled Radiator Valve (RV), simply replaces the passive
standard TRV head . The Wireless RV must be used with the wireless thermostat
VS10/VS20RF and the Zigbee co-ordinator CO10RF (all sold separately).
The wireless radiator valve can be used with the SALUS wireless boiler receiver
(RX10RF) configured to RX1 and other iT600 wireless products (see below).
VS20 Thermostat
(Required)
CO10RF
(Required)
RX10RF
(Optional)
SALUS Wiring Centre KL10RF
Product Compliance
This product is CE compliant and meets the following EC Directives Electro-Magnetic
Compatibility directive 2004/108/EC Low voltage Directive 2006/95/EC.
Safety Information
Use in accordance with the regulations. The SALUS TRV10RF is to be used for
room control inside the house.
Installation
This accessory must be fitted by a competent person, and installation must comply with
the guidance, standards and regulations applicable to the city, country or state where the
product is installed. Failure to comply with the relevant standards could lead to prosecution.
TRV10RF Installer Manual 03
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:29 Stro
System Overview
To achieve the best control from the RV + Thermostat. We recommend that
it be used with the SALUS system receiver configured to RX1. The system
receiver will turn the boiler on/off as per requested via the thermostat.
The RV is modulating,
which means it opens
or closes partially or
100% depending on
the relationship
between the actual
room temperature and
the required room
temperature measured
by the VS10/20RF.
+
Only 3 TRV’s can be connected to a VS10RF/VS20RF
04 TRV10RF Installer Manual
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:29 Stro
Installation - General
1
Detach top housing by
pressing button and
gently pulling the top
housing off.
4
Gently place the top
housing onto the
bottom housing.
Note correct orientation.
2
3
Remove the battery cap. Insert the batteries and
replace the battery cap.
Please note correct
battery orientation.
5
Ready to be fitted to
the radiator valve.
Note: The LED will flash
green and then red and
eventually go to solid
red.
Optional adapter
TRV10RF Installer Manual 05
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:29 Stro
Installation - General
6
7
8
Place the TRV over the
radiator valve.
Tighten the TRV (finger
tight) to the radiator
valve.
Check that LED is
solid red.
9
10
11
Press any button to
commence adaptive
mode.
Now wait until the unit
has completed it’s
adaptation to the valve.
This will be when all
noise and LED activity
has stopped. If LED
continues to flash refer
to page 11.
The unit is now ready
for pairing to the SALUS
thermostat.
06 TRV10RF Installer Manual
It is recommended
that pairing is
done on a room to
room basis.
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:29 Stro
Installation - Pairing
System setup checklist
1
The Zigbee coordinator must be in
pairing mode.
Before starting the pairing, make sure the light
is flashing on the coordinator by holding the
button for 5 seconds. Please refer to the
coordinator installation guide.
2
Ensure that the thermostat is powered up and ready
for configuration and pairing.
Please refer to pages 32 and 37 in the thermostat installation
guide.
3
If you are using the optional system receiver configured
to RX1 for remote boiler switching. Ensure this has been
powered up and the red flashing LED has gone steady.
Please refer to system receiver installation guide.
TRV10RF Installer Manual 07
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:30 Stro
Installation - Pairing
1
Press and hold the
pairing button for 5
seconds.
2
Once the red LED starts
flashing go to page 37
in VS10/ 20RF manual.
When pairing is successful with the VS10/20RF
thermostat then the LED will go out.
08 TRV10RF Installer Manual
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:30 Stro
User Interface
LED Indication
Manual
open/status
indication
Manual
close/status
indication
Pairing Button
TRV10RF Installer Manual 09
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:30 Stro
Status Indication
Auto Mode
Short press on either
button will show status.
LED flashes red once.
The valve is closed.
LED flashes green once.
The valve is open.
Manual Mode (See page 12)
Short press on either
button will show status.
LED flashes red twice.
The valve is manually
closed.
If RF lost link error code **-07 will
show on the connected thermostat.
10 TRV10RF Installer Manual
LED flashes green twice.
The valve is manually
open.
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:30 Stro
LED Indication
Installation Error
If there is an error in the
installation the RV LED will flash
Red / Green alternately. Please
remove the RV from the radiator
valve and repeat the installation
steps on page 6.
Low Battery
If the battery low, the red light
will flash three times every ten
seconds. When replacing
batteries follow steps 1 to 9 on
page 5 and 6.
Low battery in the radiator valve will also be shown
as error code **-22 on the connected thermostat.
TRV10RF Installer Manual 11
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:30 Stro
Manual Override
To remove the RV from auto mode, follow steps below.
Long press to
manually open RV.
Long press to
manually close RV.
LED flashes green once and then goes out.
To check status refer to previous page.
LED flashes red once and then goes out.
To check status refer to previous page.
Short press to return
to Auto mode. Red
LED will flash once to
confirm that the unit
is in AUTO.
12 TRV10RF Installer Manual
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:30 Stro
Technical Detail
Model
TRV10RF
Type
Hydraulic Radiator Valve
DC Motor
M30 x 1.5
Input
3 push buttons. Auto/Open/Close/Pair
LED Indicator
Bi-Colour, Red/Green
Valve Adaptation
Automatic
Power Source
2 x AA Batteries
Battery Life
12 Months
Control Method
Modulating
Communication
Zigbee - 2.4GHz
Operating Temperature
0 to 50ºC
Storage Temperature
-20 to 60ºC
TRV10RF Installer Manual 13
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:30 Stro
Installer Notes
14 TRV10RF Installer Manual
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:30 Stro
Warranty
SALUS Controls warrants that this product will be free from any defect in materials
or workmanship, and shall perform in accordance with its specification, for a period
of five years from the date of installation. SALUS Controls sole liability for breach of
this warranty will be (at its option) to repair or replace the defective product.
Customer Name: ..................................................................................
Customer Address: ..................................................................................
................................................. Post Code: ..........................................
Tel No: ..................................................................................................
Email: ..................................................................................................
Engineers Company: ............................................................................
Tel No: ...................................................................................................
Email: ..................................................................................................
Instalation Date: ..................................................................................
Engineers Name: ..................................................................................
Engineers Signature: ............................................................................
TRV10RF Installer Manual 15
iT600 TRV10RF Manual 008_Layout 1 17.06.2014 15:30 Stro
SALUS Controls plc
SALUS House
Dodworth Business Park South,
Whinby Road,
Dodworth, Barnsley S75 3SP, UK.
SALES:
T: +44 (0) 1226 323961
E: [email protected]
TECHNICAL:
T: +44 (0) 1226 323961
E: [email protected]
www.salus-controls.com
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc
reserve the right to change specification, design and materials of products
listed in this brochure without prior notice.
Issue Date: May 2014
00086/2
For PDF Installation guide please
go to www.salus-controls.com