Single Zone Air Conditioner SVC MANUAL(Exploded View) CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. MODEL : AUUW36GD2 [MR36UY3J] 960-920-10 1. Specification ABNH36GRLA2 [MD36Y3J] ATNH36GMLE2 [MC36Y3J] 4.7~10.5~12.1 16,200 ~ 36,000 ~ 41,400 5.2 ~ 11.7 ~ 13.4 18,000 ~ 40,000 ~ 46,000 2.97 3.36 12.1/17.6 / 9.2 4.10 ~ 10.5 ~ 12.3 14,000 ~ 36,000 ~ 42,000 4.25 ~ 11.7 ~ 13.1 14,500 ~ 40,000 ~ 45,000 2.97 3.2 13.5 / 19.0 / 9.5 Indoor Unit Min. ~ Rated ~ Max. Min. ~ Rated ~ Max. Min. ~ Rated ~ Max. Heating Min. ~ Rated ~ Max. Cooling Rated Heating Rated Cooling Capacity Power Input EER / COP SEER / HSPF kW Btu/h kW Btu/h kW kW Btu/h·W Btu/h·W Rated Rated Rated Outer Dia. Outer Dia. Max. W x No. dB(A) dB(A) dB(A) mm(inch) mm(inch) m (ft) AUUW36GD2 [MR36UY3J] 208-230 / 1 / 60 3C x 5.0 (10) Warm Gray 950 × 1,380 × 330 37-13/32 × 54-11/32 × 13 92.0 (202.8) Twin Rotary GPT442MBA x 1 BLDC 4,000 x 1 R410A 3,400 (119.9) 7.5 (24.6) 40 (0.43) Electronic Expansion Valve FVC68D 1,300 x 1 (2 x 32 x 14) x 2 Propeller 55(1942)×2 BLDC 124.0 x 2 52 54 67 Ø 9.52 (3/8) Ø 15.88 (5/8) 75 (246.1) Max. m (ft) 30 (98.4) Min. ~ Max. Min. ~ Max. ℃ DB (℉ DB) ℃ WB (℉ WB) -15 (5.0) ~ 48 (118.4) -18 (-0.4) ~ 18 (64.4) Model Name Power Supply Starting Current Wiring Connections Casing Color V , Ø , Hz A A No. x mm2 (AWG) mm inch kg (lbs) Model x No. W x No. g (oz) m (ft) g/m (oz/ft) cc x No. m3/min(ft3/min) x No. Cooling Max. Heating Max. Power Supply Cable (included Earth) WxHxD WxHxD Dimensions Net Weight Compressor Refrigerant Refrigerant Oil Heat Exchanger Fan Fan Motor Sound Pressure Level Type Model Motor type Motor Output Type Precharged Amount Chargeless-Pipe Length Additional Charging Volume Control Type Charged volume (Row x Column x Fins per inch) x No. Type Air Flow Rate Type Output Cooling Heating Sound Power Level Piping Connections Liquid Gas Piping Length Outdoor Unit ~ Indoor Unit Cooling Operation Range (Outdoor Temperature) Heating Maximum Height Difference Note: 1. All data are based on the following conditions: - Cooling Temperature : Indoor 26.7℃(80℉) DB / 19.4℃(67℉) WB Outdoor 35℃(95℉) DB / 23.9℃(75℉) WB - Heating Temperature : Indoor 21.1℃(70℉) DB / 15.6℃(60℉) WB Outdoor 8.33℃(47℉) DB / 6.11℃(43℉) WB - Piping Length : Interconnected Pipe Length = 7.5m - Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero. 2. Wiring cable size must comply with the applicable local and national code. 3. Due to our policy of innovation some specifications may be changed without notification. 4. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased(maximum 3dB(A)) owing to ambient conditions during operation. Only for training and service purposes -2- 2. Piping Diagrams Outdoor Unit Sensor for Sensor for Heat exchanger Heat exchanger inlet air temperature Outlet temperature Refrigerant Flow Cooling Heating Sensor for Heat exchanger temperature Ø9.52 Flare Connection M Strainer Strainer Electronic Expansion Valve Pressure Sensor 4 way Valve Ø15.88 Flare Connection Sensor for discharge temperature Accumulator Sensor for suction temperature Inverter Compressor Description PCB Connector Sensor for suction temperature CN_TH3 Sensor for discharge temperature Sensor for Heat exchanger inlet air temperature Sen for Heat exchanger inlet air temperature Sensor for Heat exchanger temperature CN_TH4 Pressure Sensor Only for training and service purposes CN_TH2 P-SENSOR(H) -3- 3. Wiring Diagrams MAIN PCB CN_MOTOR1 CN_MOTOR2 CN_N/F CN_EEV1 CN_4WAY CN_COOLING CN_TH2 CN_TH3 P_SENSOR (H)-RD CN_TH4 Only for training and service purposes -4- 4. Exploded View 549610 554030A 237204 552111 435300 552115 559010 546810A 352111 546810B 559010 435512 554030B 649950 55211G 263230C Air / Cond-Out 237202 Cond-Mid 263230A 349480 548490 661400 437212 552200 268711A 261704 552117 W6200 237205 W52240 W4810 435301 W0FZZ 263230B 552202 W6640 Suction / Discharge pipe 561410 447910 148000 165010 Pressure sensor 135500 552560 552203A 349480 435301 552116 W6631 552203B 437211 554160 435513 137213 430410 152503 Location No. 263230A 263230B 263230C 165010 Description Thermistor S2(CN-TH4) Thermistor S4/S3(CN-TH3) Thermistor S6/S5(CN-TH2) Pressure sensor(P-SENSOR (H)-RD) Only for training and service purposes -5- Sensor Information Cond-Mid Suction /Discharge pipe Air / Cond-Out Pressure Sensor 550140B Housing Color Blue Red White Red P/No : MFL67690608
© Copyright 2024