Krones HS Contiroll Training Manual Page 1 of 56 Krones HS Contiroll Training Manual Instructor Booklet Krones HS Contiroll Training Manual Page 2 of 56 Target Audience Niagara machine operators Maintenance team members Mechanics Topics to be Discussed Design, safety, and function of the Contiroll HS Pneumatic components Touch-screen menu Maintenance and lubrication Basic knowledge of electrical components Handling containers and labels Elementary process for troubleshooting Description of Day One The first day of the instruction will include safety, theory of operation, sanitation, container and label handling, operation of touch screen controls, changeover procedures and basic component adjustments. A pretest will be administered to assess the skill level of participants. After the assessment a class discussion and question/answer period will take place. Description of Day Two On the second day of instruction trainees will have hand-on programming of the cut controller. Additionally, trainees will work on a misadjusted simulator, cuting drum, gripper cylinder, and adhesive station. The trainer will walk the group through a preform label reel changeover, basic set-up and timing procedures, and machine adjustments. In the second part of day two training on the Krones HS Contiroll Labeler, the trainer will walk though or demonstrate basic troubleshooting measures, preventative maintenance procedures and parts ordering. After the demonstration the trainer will have a question and answer session the instructor will administer a quiz and conduct a question and answer period. Krones HS Contiroll Training Manual Course Agenda Introduction to Krones HS Contiroll Safety Describe warning indictors Overview of parts Starting Up the Krones HS Contiroll Operating Krones Contiroll Touch screen Demonstrate creating a label with the Contiroll Create a quality label Define short term production interruptions Changing over Cutting labels Cleaning Page 3 of 56 Krones HS Contiroll Training Manual Page 4 of 56 Safety Safety Labels When operating the Krones HS Contiroll Labeler it is important to follow the safety guidelines. Make sure to follow all the warning and labeled guidelines for solvents and chemicals. Pay attention to the following warning labels on the machine. Burn Hazard Pinch Point – Moving Parts Electrical Shock Hazard Krones HS Contiroll Training Manual Page 5 of 56 Safety Devices Human Machine interface Emergency Stop Emergency Stop Switch Emergency Stop Switch Describe a situation in which you might have to use the emergency safety stops. Krones HS Contiroll Training Manual Page 6 of 56 Machine Doors Safety Switch on Main Door. Cutting Unit Guard Door Do not reach into the cutting guard doors while the machine is being jogged. Safety Switch on the Cutting Guard Door. Notes Krones HS Contiroll Training Manual Page 7 of 56 Control Cabinet Doors If there is a malfunction call an electrician. Do not proceed to turn on the machine. The control cabinet doors and machine guards must all be closed. Hot Melt Unit Be sure to wear protective gloves and glasses when working on hot parts. The guards must be installed on the hot melt unit before production. Notes Krones HS Contiroll Training Manual Page 8 of 56 Starting Up the Krones HS Contiroll Labeler Starting up a. Set the main switch to the ON position b. The data screen is displayed after 2 minutes c. The heaters take 20 minutes to reach the desired temperature. Turn the main switch to the ON Position. Checking the Air Pressure Verify the main air pressure is within range (approx. 6 bar). Notes Krones HS Contiroll Training Manual Page 9 of 56 Logging onto the Machine Be sure to log off to the machine after you are done. Use the green transponder to log onto the machine. Machine Mode Turn the key horizontally to enter the set-up mode. Type Selection Make sure the type in dark blue is correct. Notes Krones HS Contiroll Training Manual Lamp Test Page 10 of 56 Ver. 6.20 - MMA, Functions, Aux. Functions, Lamp Test Ver. 6.22 – Krones, Functions, General, Lamp Test Handling Parts Pay attention to the marks and refer to the Krones handling parts overview Machine Head Ver. 6.22 - Krones, Functions, General, Lamp Test Check the supporting column to make sure the machine head is at the correct height. Checking Mechanical settings a. Make sure you use the correct graphics as well as UPC codes. Ver.labels. 6.22 -Verify Krones, Functions, b. Clean the cutter drum, vacuum-assisted ripper cylinder, sensors and reflectors. These General, Lamp Test parts should be cleaned regularly. Explore the labeler on the plant floor, walk through the various mechanical settings and preform a lamp test. Describe the results of the lamp test, and list any questions from the walk through below. Krones HS Contiroll Training Manual Page 11 of 56 Rotary cutter Check the compressed air pressure of the cutter clamping bars once per shift (when applicable. Connect the compressed air gun to the valve and inflate the pressure pad. (Min. of 5 bars required) Ver. 6.22 - Krones, Functions, Do not release the compressed air gun General, valve unless you have removed the gun from the valve. Lamp Test Notes Krones HS Contiroll Training Manual Page 12 of 56 Guidance of Label Film Check if the deflection rollers run smoothly and the label film has been threaded correctly using numbers and the threading diagram. Safety a. Make sure all the guard doors are closed and there is no one in the danger zone b. Make sure the emergency stop switch is activated. Label Position Check the height of the reel holders and the ultrasonic sensor Register Mark Sensor Setting the Cut- off Position Check the supporting column to make sure the machine head is at the correct height. Ver. 6.22 - Krones, Functions, General, Lamp Test Krones HS Contiroll Training Manual Page 13 of 56 Check the container passage a. Pay special attention to the transfer points between infeed worm, infeed, starwheel, carrousel, and discharge starwheel. b. Check the cutting of the label, the transfer points, and the gluing of the leading/trailing edge of the labels. Release the container stop and jog a few containers into the machine. Ver. 6.22 - Krones, Functions, General, Lamp Test Make sure the container stop locked. Press JOG and hold it. Switching to Automatic Mode a. Close the guard doors b. Reset the malfunction warnings Ver. 6.22 - Krones, Functions, Ver. 6.22 - Krones, Functions, General, Lamp Test General, Lamp Test Use the key switch to set the machine to automatic mode (vertical key position). Ver. 6.22 - Krones, Functions, Select AUTO mode. General, Lamp Test Ver. 6.22 - Krones, Functions, General, Lamp Test Krones HS Contiroll Training Manual Page 14 of 56 During Production Pay attention to any warnings on the touch screen . To navigate to the alarms go to Krones – Messages – Active Alarms Touch Screen Warning Indicators Notes from the touch screen Warning Malfunction warnings STOP the machine immediately. If there are several alarms you might have to call up the list or refer to the help menu (top right of the touch screen) Gluing Unit Regularly check the quantity of glue in the reservoir and refill to recommended level when needed. Do not refill the glue too much at once, or otherwise the temperature will drop. Ver. 6.22 - Krones, Functions, Containers Check the conveyors for container s which haveTest been fallen over. General, Lamp Make sure the containers enter the machine smoothly. Krones HS Contiroll Training Manual Page 15 of 56 Quality of Labeling Regularly check the quality of labeling. Pay special attention to: The correct label position. Gluing and glue pattern on the label. Dimension tolerance of the containers. Clean and dry containers. Cut-off point deviation and cut quality. Machine Assemblies 1. Infeed 2. Reel holder and splicing unit 3. Labeling station with cutting unit and vacuum-grip cylinder 4. Gluing unit 5. Machine head and carrousel 6. Machine table with base 7. Screen Name each of the components above 1 2 3 4 5 6 7 Krones HS Contiroll Training Manual Label Passage Overview Container passage / back-up switches (infeed / discharge) Page 16 of 56 Krones HS Contiroll Training Manual Page 17 of 56 Back-up switches at the infeed (E1, E2, E3) and discharge (A1, A2, A3) of the machine detect the flow of containers. They regulate the machine speed and stop the infeed worm if necessary. There is also a so-called speed control system where a central computer controls the speed of the complete line. The "infeed monitoring" sensor checks the container flow at the infeed of the machine. It monitors whether the containers enter the machine in an upright position or whether they have fallen over. Notes Krones HS Contiroll Training Manual Notes Page 18 of 56 Krones HS Contiroll Training Manual Page 19 of 56 Labeling Quality of the label Regularly check the quality of labeling. To do so, remove containers from the discharge conveyor. Make sure to pay attention to: Correct label position Amount of glue and glue pattern on the label Dimension tolerance of the containers Clean and dry containers Cut-of point deviation and cut quality Container passage / labeling station Krones HS Contiroll Training Manual The cut and glued label is transferred to the container passing by. The label transfer accuracy is essential for quality. The container plates must rotate to ensure that the container picks up the label correctly from the vacuum-grip cylinder. The container plates are turned by a servomotor using a toothed belt. Page 20 of 56 Krones HS Contiroll Training Manual Describe the purpose of each machine part listed below Servomotor Label film guider Gluing unit Vacuum-grip cylinder Feed roller Cutting unit Label carrier film buffer Reel holder Splicing unit Page 21 of 56 Krones HS Contiroll Training Manual Page 22 of 56 Label passage / reel holder The label film is unwound using a servomotor. The machine controller determines how much label film is required. Sensors have been installed for detecting the reel diameter and the end of the reel. Label passage / splicing unit The splicing unit is used for the exact transfer of the new label reel to the empty reel. The leading end of the label film is threaded manually in the device, held with vacuum and taped down with double-sided adhesive tape. Krones HS Contiroll Training Manual Page 23 of 56 Label passage / reel change-over The machine continues operation while the reel is being changed. The splicing unit cuts off the label film of the used reel and bonds it automatically to the new reel. Notes Krones HS Contiroll Training Manual Page 24 of 56 Change-Over and Set Up This chapter describes the type change-over for types that has already been set up and tested successfully. The change-over of the container type and label is described here. It is important that a specified sequence be followed: 1. Preparation 2. Type change-over on the touch screen 3. Changing over and setting the main machine (MMA) 4. Changing over and setting the labeling stations (LS1/LS2) 5. Testing the container passage Preparation Read your production documents thoroughly so that you know for certain which type you wish to produce. Obtain the correct labels and prepare some containers in the infeed. Obtain all the handling parts that are required for the new type and place parts on the machine. Check this identification to ensure that you are using the correct parts. Change-over on the Touch-screen On the touch screen, navigate to Krones – Type Management – Type Parameters (some parameters may require a higher level access). Select “Type Management” from the drop down menu. Ver. 6.22 - Krones, Functions, General, Lamp Test Accept the type Ver. 6.22 - Krones, Functions, General, Lamp Test Krones HS Contiroll Training Manual Page 25 of 56 Confirm the type change. Setting the machine When changing over and setting the machine it is important to lock out/tab out to prevent it from being turned on unintentionally. Machine Mode Ver. 6.22 - Krones, Functions, General, Lamp Test Use the key to switch the machine to the set-up mode (horizontal key position). Height Adjustment System, Machine Head On the touch screen, navigate to -MMA-Functions-General height adjustment. The Ver. 6.22 Krones, Functions, machine head needs to be at the topmost position. General, Lamp Test Krones HS Contiroll Training Manual Page 26 of 56 Bottle Present Sensor Loosen the clamping lever and swing the bottle present sensor to the side prior to the changeover. Guide Rails Change the infeed and discharge guide rails. Pay attention to the Ver.numbers 6.22 - Krones, item when Functions, changing the parts. General, Lamp Test Notes Ver. 6.22 - Krones, Functions, General, Lamp Test Krones HS Contiroll Training Manual Page 27 of 56 Changing the Stop Starwheel Lift off the knob of the supporting bolt and pull down the knob of the vacuum cylinder, then remove the stop starwheel. Infeed Worm Ver. 6.22 - Krones, Functions, General, After Lampyou Testremove the clamping lever you can pull the worm out of the drive shaft. Open the clamp and swing out the housing. Infeed Worm Lubrication Infeed worms can easily jam; make sure that they are in a horizontal position during assembly and disassembly. Before fitting the drive shaft, lubricate it sufficiently. Krones HS Contiroll Training Manual Page 28 of 56 Adjusting the Infeed Guide on the Infeed Worm Turn the rotatable stop adjustment system below the infeed worm to the required position. Ver. 6.22 - Krones, Functions, Then turn the star gripTest at the front side General, Lamp until the required position is reached (the bolt head is used as a stop). Ver. 6.22 - Krones, Functions, General, Lamp Test Guide Flap Pull out the bolt and remove the flap. Make sure the bolt is not jammed, the flap is guided by a bolt head. Infeed/Discharge Starwheels Ver. 6.22 - Krones, Functions, General, Lamp Test Swing the sensor back to the stop (to production position) and retighten the clamping lever. Krones HS Contiroll Training Manual Page 29 of 56 How to Use the Bottle Present Sensor Swing the sensor back to the stop (to production position) and retighten the clamping lever. Ver. 6.22 - Krones, Functions, Container Plates Make sure the container plates are properly engaged. General, Lamp Test To change the container plate, press the lever of the clip and then lift off the plate. Ver. 6.22 - Krones, Functions, Centering Bells General, Lamp Test Lubricate the centering bolt before fitting the bell. Press the lever on the clip, pull down and then remove the bell. Ver. 6.22 - Krones, Functions, General, Lamp Test Krones HS Contiroll Training Manual Page 30 of 56 Rolling-on Unit Change the parts of the rollingon unit using an open-end wrench. Height Adjustment system and Machine Head Ver. 6.22 - Krones, Functions, General, Lamp Test Move the machine head to the correct height on this supporting column. Ver. 6.22 - Krones, Functions, General, Lamp Test The exact height of the machine head is reached if the clearance is between 8 - 12 mm. Ver. 6.22 - Krones, Use a containerFunctions, to check the exact height. General, Lamp Test Krones HS Contiroll Training Manual Page 31 of 56 Changing-over and adjusting the LSx Labeling Station Setting the labeling station Retract the labeling station using the hand wheel. Changing the Vacuum-assisted Gripper Cylinder Ver. 6.22 - Krones, Functions, The vacuum-assisted gripper cylinder must rest properly on the vacuum disk. General, Lamp Test Lift the vacuum assisted gripper cylinder off the polygon shaft. Pay attention to the zero reference point mark when setting down the vacuum-assisted gripper cylinder. Mechanical Adjustments The mechanical adjustments have been stored as a “note” in the touch screen. The control system does not use these Ver. 6.22i.- e. Krones, Functions, values, they only serve as a information for the operator and must General, Lamp Test be adjusted manually on the machine. Ver. 6.22 - Krones, Functions, General, Lamp Test Krones HS Contiroll Training Manual Page 32 of 56 Register Mark Sensor Release the clamping lever and set the sensor to the specified scale value. Retighten the clamping lever. Inclination, Labeling Station Set both registers (value A) to the specified value using an open-end wrench. Loosen the lock screws on both sides of the labeling station. Height Adjustment System, Labeling Station The labeling station can be raised or lowered using the push buttons. Set the register (value B) to the specified value. Label Web Guide Loosen the lock screw, set the ultrasonic sensor to the specified scale value (value C), and retighten the lock screw. Krones HS Contiroll Training Manual Page 33 of 56 Labeling station, forward/backward Actuate the register (value D) using the hand wheel and adjust the labeling station to the specified value. Reel Holder Release the clamping lever; reelFunctions, holders to the Ver.adjust 6.22 -both Krones, specified value. Retighten the General, Lamp Test clamping lever. Vacuum-assisted gripper cylinder If the pressure on the vacuum-assisted gripper cylinder is too low follow the instructions below. Ver. 6.22 - Krones, Functions, General, Lamp Test Check the value on the vacuum pressure gauge. Ver. 6.22 - Krones, Functions, General, Lampadjust Test the specified If necessary, value using the lever of the valve. Ver. 6.22 - Krones, Functions, Krones HS Contiroll Training Manual Page 34 of 56 Pressure in the Cutter Drum too Low Check the value on the vacuum pressure gauge (this value is always lower than that on the vacuum-assisted gripper cylinder for label transfer). If necessary adjust the specified value using the lever of the valve. Blowing Pressure on the Cutter Drum Adjust the pneumatic valve to the specified value using the scale. Adjusting the Label Height Check the correct label position on the vacuum-assisted gripper cylinder The label must protrude approximately 2 mm beyond the vacuum bar. Notes Krones HS Contiroll Training Manual Page 35 of 56 Manual Feed Switch the machine to the set-up mode using the key switch Switch the feed roller to manual operation and feed some labels in the jog mode. Register Mark Sensor The arrow indicates the current position of the sensor light on the label. Jog the small back arrow in the LS1/LS2 graph to the position shown. Checking the Label Cut Feed and cut some labels in the set-up mode and remove them manually. The cutting position will move closer to the required position each time a label is cut. Testing the Container Passage To test the container passages first navigate to LS1/LS2 – Functions – Main Functions. Set the feed roller on the touch screen to AUTO. Krones HS Contiroll Training Manual Page 36 of 56 Changing the Label Reels Touch Screen Message A message on the touch screen will appear alerting you to change the label film reel. Ver. 6.22 - Krones, Functions, Reel Holder General, Lamp Test Replace the empty label film roll (release air from holder) Install new roll (pressurize again). Ver. 6.22 - Krones, Functions, Vacuum Selector General, Lamp Test Use this button to unwind sufficient label film. Set the vacuum selector switch Ver. 6.22 - Krones, Functions, for splicing to the label film reel. General, Lamp Test Ver. 6.22 - Krones, Functions, General, Lamp Test Krones HS Contiroll Training Manual Page 37 of 56 Preparing Label for Splicing Unit Align label in clamp to ensure it is cut in the center. Ver. 6.22 - Krones, Functions, General, Lamp Test Align label in clamp to ensure it is cut in the center. Ver. 6.22 - Krones, Functions, General, Lamp Test Applying Adhesive Tape Splicing tape is applied to print side on right hand label roll (1), and back side of left hand label roll (2). (Tape is applied in the center of the label and approx. 4mm from end) Krones HS Contiroll Training Manual Page 38 of 56 Setting Up the Splicing Unit Switch vacuum to hold label on the side that is needed. Position label so that is the recommended height and position. Close the Splicing Unit Make sure that the label has not shifted Close the splicing unit using the flap stops. Reactivate the Pneumatic Brake The brake is released automatically when the reel is changed. Brake Release 0 = Brake blocked 1 = Brake released Krones HS Contiroll Training Manual Page 39 of 56 Short-Term Production Interruptions During the course of a workday it might be necessary to turn off the labeler. Follow the instructions for turning off the equipment for a short-term production interruption. Lock the infeed stop and make sure the machine is emptied. Press here to close the infeed stop. Turn the Machine OFF, but the heater remains ON Press here to turn off the machine. After the interruptions are complete, turn the machine back on. Press here to turn on the machine. Observe the first containers that run through and check their quality. Adjust the container stop to AUTO Krones HS Contiroll Training Manual Page 40 of 56 End of Production and Machine Shutdown In order to empty the machine, adjust the infeed stop to manually open (1). After the gap detector has responded press the RESET button on the gap detector and hole it. Then empty machine of all container stop (2). 1 2 Container Stop Infeed Stop Turn the machine and conveyors OFF Lock Out/Tag Out the machine to prevent it from being turned ON. Turn the machine and conveyors OFF. Notes Krones HS Contiroll Training Manual Page 41 of 56 Label passage / label carrier film buffer The label film is threaded through the rollers according to the marks (numbers and arrows). The buffer continuously tensions the label film to prevent it from falling down. It also ensures a sufficient supply of label film during splicing. A sensor on the bottom side monitors the current position. Krones HS Contiroll Training Manual Page 42 of 56 Label passage / label film guider A label film guider has been provided to maintain the label carrier film in the required horizontal position. A sensor monitors the required label height. Label passage / register mark sensor The register mark sensor records the register marks provided. These signals are processed by the controller and the label length is readjusted. Krones HS Contiroll Training Manual Page 43 of 56 Label passage / feed roller The calculated label length is achieved by means of a servomotor on the feed roller. The pinch roller presses the label film against the feed roller. Notes Krones HS Contiroll Training Manual Page 44 of 56 Label passage / cutting unit The label film is cut to the required length by the cutting unit. It comprises a vacuum-assisted cutter drum and a cutting rotor with separate servomotor. An encoder for determining the exact position is provided both on the rotor and the roller. Notes The label is cut when the cutter meets the cutting strip. Labels can be cut to different lengths. o L min. = 170 mm o L max. = 600 mm Krones HS Contiroll Training Manual Page 45 of 56 Label passage / gluing unit The gluing unit comprises a glue bowl, a glue roller and two glue scrapers. A label wiper is also installed. Notes Hot glue is pumped from the bowl to the roller. A glue film is provided through the gap set between the glue scrapers and the roller. Heating elements and temperature sensors have been installed in the gluing unit. Krones HS Contiroll Training Manual Page 46 of 56 Label passage / vacuum-grip cylinder Vacuum bars on the vacuum-grip cylinder take the labels from the cutter drum. Through the contact with the glue roller, a strip of glue is applied to the leading and trailing edge of the label. Afterwards, the label is transferred to the container. Sensor 2: Label must be provided Sensor 3: Label must not be provided Krones HS Contiroll Training Manual Notes Page 47 of 56 Krones HS Contiroll Training Manual Page 48 of 56 Control elements / touch-screen Cleaning Clean the labeler at regular intervals to avoid problems Use short term production interruptions for learning (e.g. lack of containers at infeed), especially in the area of the cutting unit, glue scraper, vacuum-assisted gripper cylinder, and on the deflection rollers Cleaning Tools Do NOT use any sharp edged tools, especially in the area of the cutting unit and the vacuum-assisted gripper cylinder. Do NOT use a higher pressure washer Use only lint-free industrial cloths, a brush, or a sponge for cleaning. Refer to the operating manual for cleaning intervals and instructions. Krones HS Contiroll Training Manual Page 49 of 56 Main Machine To start cleaning you first want to remove all labels and other production residues that have been left in the machine. Sensors Regularly clean container present sensor and reflector. Regularly clean sensors 2 & 3. Monitoring 2 = Label MUST be provided. Monitoring 3 = Label MUST NOT be provided. Feed Roller Remove debris from the feed roller as well as the pinch roller. Krones HS Contiroll Training Manual Page 50 of 56 Gluing Unit Remove labels that have accumulated in the gluing unit and on the glue scraper. Vacuum-assisted gripper cylinder Be careful of the plastic parts JOG the vacuum-assisted gripper cylinder one complete revolution to ensure all have been cleaned. Remove debris from the vacuum bars and the vacuum holes. Cutting Unit Dirt on the surface and in the vacuum holes impairs the cutting behavior (formation of chips, label tears). Regularly clean the cutter drum and the anvils. Notes Krones HS Contiroll Training Manual Page 51 of 56 Clean all vacuum holes on the cutter drum using a drill bit (1.5mm). Turn the drill bit while pulling it out to remove contaminations. Brushing-on Unit/rolling on Unit Remove debris between the brushes and on the sponge roller. If the contamination is severe remove the parts for cleaning. Deflection Rollers Remove contaminations on the deflection rollers, on the splicing unit, the buffer system, and on the label web guider. Krones HS Contiroll Training Manual Page 52 of 56 Cleaning Agents Several machine components can be seriously damaged if aggressive solvents are used. Component Vacuum bars, vacuum assisted gripper cylinder, and splicing unit Plant approved solvent Cutting Unit Glue reservoir Plant approved solvent Component Medium Sensors Damp cloth Rolling-on unit Plant approved solvent Component Medium Door panels Warm water, Soap suds, Window cleaner, Cleaning alcohol (max. 25%) Touch screen Damp cloth Cleanfix cleaning oil, Hot clean, UV (depending on the glue type) Rolling-on unit Warm water, Cleanfix EV 60, Cleanfix Standard Table area Warm water Medium Identify what cleaning chemicals you have on hand at your plant, write the answers below. Krones HS Contiroll Training Manual Page 53 of 56 Maintenance and Possible Malfunctions Problem: Label film Torn If the label tears in the labeling station, this will be signaled by the sensor in the buffer system and the machine will be stopped automatically. What to do After the label film has torn, the label film must be rethreaded. Arrows are provided on the deflection rollers showing the precise route of the label film. Refer to threading diagram. Causes of Rethread Look for possible causes for the label film tear (label material, sluggish deflection rollers, sharp edges, foreign bodies, etc.) and eliminate them. Resume Production Once you have re-threaded the label film, proceed to start the machine. Problem: Label Lengths Outside Tolerances If the actual label length is continuously cut larger or smaller than the permissible tolerance (+0.5% of the required label length) the reason may be a faulty print of the label (distance between register marks). This fault can also occur in an individual label reel. What to do Check the quality of the labels: Is the register mark printed clearly? Are they electrostatically charged? Do they always have the same lengths? Use a new label reel from the store and watch to see whether the fault continues to occur. Krones HS Contiroll Training Manual Page 54 of 56 Resume Production Once you have checked the quality of the labels, proceed to start the machine. Problem: Register Mark It is possible that the machine controller loses the register mark. If 5 subsequent register marks (standard value) are not detected, the machine will be stopped automatically… What to do Check where the register mark is positioned on the label. Check whether the label length is outside the tolerance. Check whether the mark color or width changes. Check whether the register mark clearly stands out from the rest of the label. Problem: Label Transfer from the Cutter Drum to the Vacuum-assisted Gripper Cylinder Machine Mode Use the key to switch the machine to the set-up mode. Cleaning Clean the cutter drum or the vacuum assisted gripper cylinder. The Pressure in the Cutter Drum is too Low Adjust the correct vacuum in the cutter drum. Krones HS Contiroll Training Manual Page 55 of 56 Blowing Pressure on the Cutter Drum Adjust the correct blowing air pressure on the cutter drum. Label Pick up by the Vacuum-assisted Gripper Cylinder Check whether the clearance between the cutter drum and all vacuum bars on the vacuum-assisted gripper cylinder is 0.6mm. Rotate the vacuum cylinder manually to the position shown. The rear edge of the trailing edge vacuum bar must be shifted by 2mm to the center of the anvil bar (label overlap). Call a Mechanic If you have are still having problems with the label or the vacuum-assisted gripper cylinder call a mechanic. Problem: Label Transfer from the Vacuum-assisted Gripper Cylinder to the Container Pressure Between Leading-edge Vacuum Bar and Container Check the pressure between the leading-edge vacuum bar and the container (dimension 12mm depending on the container/product). Call a Mechanic Call a mechanic is you are still having problems with the vacuum assisted gripper cylinder or the container. Label Transfer to the Container Jog a container into the cut-of point between the center of the polygon shaft (vacuum-assisted gripper cylinder) and the center of the carrousel. Krones HS Contiroll Training Manual Page 56 of 56 The three centers (vacuum-assisted gripper cylinder – container – carrousel) must be in alignment with each other. To ensure a correct label transfer, the center of the leading-edge vacuum bar (flat surface/glued label surface) must meet the center of the container. Call a Mechanic If you are still having problems with the label transfer to the container call a mechanic.
© Copyright 2024