FLINTEC ...the right weigh Lastcell UB1 Type UB1 Load Cell En produkt från Flintec IP 68 Flintec load cells are designed to meet the most stringent accuracy requirements. Certifications have been obtained from Weights & Measures Authorities, worldwide. UB1 universal load cells are available in the capacities 10 kN to 50 kN (1020 kg to 5099 kg) and include Accuracy Classifications GP, C1 and C3 according to OIML R 60. They offer total stainless steel construction and complete hermetic sealing, making them suitable for use in the toughest industrial environments. The Flintec calibration technique (in mV/V/) eliminates time consuming corner calibration in multiple load cell systems. The UB1 is available for use in hazardous areas zone 1, 2 (gas) and 21, 22 (dust) according to EEx ia IIC T6...T4 T130°C ATEX. www.flintab.se Kabelvägen 4 • 553 02 Jönköping Tfn 036-31 42 00 • Fax 036-18 50 79 E 10 [email protected] 11/02 1/2 www.flintec.net APPROVED Important Features • Capacities: 10 kN to 50 kN. • High accuracy. • Total stainless steel construction. • Complete hermetic sealing. • Protection IP 68. • High input resistance: 1100 . • W&M certified for 3000 intervals. • Calibration in mV/V/. • Easy cable replacement. • Complete range of loading hardware available. • Factory mutual approved. Option • Explosion protection zone 1, 2, 21 and 22 ATEX. Lastcell UB1 FLINTEC ...the right weigh Maximum capacity (=Emax ) Metric equivalents (1 N=0.10197 kg) Rated Output (=RO) Calibration in mV/V/ (A...I classified) Accuracy class according to OIML R 60 Maximum number of verification intervals (n) Minimum load cell verification interval (vmin ) Combined error Creep error (30 minutes) / DR Temperature effect on minimum dead load output Temperature effect on sensitivity Excitation voltage Zero balance Input resistance Output resistance Insulation resistance (100 V DC) Compensated temperature range Operating temperature range Safe load limit Ultimate load Load cell material Sealing Protection according DIN 40.050 kN kg mV/V %RO %RO %RO %RO/°C %/°C V %RO M °C °C %Emax %Emax 10 / 20 / 50 1020 / 2039 / 5099 2 ± 0.1% ± 0.05 ( ± 0.005) (GP) C1 C3 n.a. 1000 3000 n.a. Emax /5000 Emax /5700 ± 0.040 ± 0.030 ± 0.020 ± 0.060 ± 0.049 ± 0.016 ± 0.0040 ± 0.0028 ± 0.0024 ± 0.0020 ± 0.0016 ± 0.0011 5...15 ± 1.0 1106 ± 5 1000 ± 1 5000 –10...+40 –40...+80 200 300 stainless steel 17-4 PH (1.4548) complete hermetic sealing; cable entry sealed by glass to metal header IP 68 Dimensions L 41 W H L 86 143 H 92 136 W 30 43 Thread D M16 M242 All dimensions in mm. Dimensions and specifications are subject to change without notice. * E 10 11/02 2/2 Unified thread 5/8-18 UNF (10...20 kN) and 1-12 UNF (50 kN) is available. Wiring • The load cell is provided with a shielded, 4 conductor cable (AWG 24). • Cable length: 6 m. • Cable diameter: 5 mm. • The shield is floating. + Input (green) + Output (white) – Input (black) – Output (red) Shield Huvudkontor: Flintab AB (yellow) 2004-04-01 Type UB1-10k N/20 kN UB1-50 kN Vi förbehåller oss rätten att ändra tekniska och/eller kommersiella delar av detta dokument utan föregående avisering. D* Distriktskontor: www.flintec.net KabelvägenFlintab 4 553 JÖNKÖPING TelJönköping 036-31 42 00 MALMÖ www.flintab.se 040 [email protected] AB,02 Kabelvägen 4 • 553 02 - 18 10 30 GÖTEBORG 031 - 48 00 25 Tfn 036-31 42 00 • Fax 036-18 50 79 www.flintab.se • [email protected] ESKILSTUNA SUNDSVALL 016 - 13 76 20 060 - 58 05 20 STOCKHOLM 016 - 13 76 20 Utgåva 2013-04-22. Mått i mm där ej annat anges. Vi förbehåller oss rätten att ändra tekniska och/eller kommersiella delar av detta dokument utan föregående avisering. UB1 Specifications
© Copyright 2024