OPTIMALNA IZBIRA, NABAVA, VGRADNJA, DELOVANJE, VZDRŽEVANJE IN RAZGRADNJA KURILNE NAPRAVE TER PRIMERI IZ PRAKSE BLED, 8. DECEMBER 2014 ENERGETSKI SVETOVALEC ENSVET ANDREJ SVETINA NE SPREGLEJTE: • 080 1669… BREZPLAČNA TELEFONSKA ŠTEVILKA ENERGETSKO SVETOVALNE MREŽE ENSVET • www.ensvet.si …SPLETNA STRAN, KJER SE NAHAJAJO KONTAKTI S PISARNAMI, VSTOPNA TOČKA ZA ELEKTRONSKA VPRAŠANJA OBČANOV IN ČLANKI • www.ekosklad.si... JAVNI POZIVI ZA UGODNO KREDITIRANJE IN NEPOVRATNE FINANČNE SPODBUDE – SUBVENCIJE NEKAJ DEFINICIJ • TEMPERATURNI PRIMANKLJAJ ( danK ) JE ZMNOŽEK DNI GRETJA IN TEMPERATURNE RAZLIKE MED IZBRANO NOTRANJO TEMPERATURO, KI JE OBIČAJNO 20ºC IN POVPREČNO TEMPERATURO ZUNANJEGA ZRAKA V OBDOBJU GRETJA. ČAS OGREVANJA OMEJIMO NA DNI, KO JE POVPREČNA TEMPERATURA ZUNANJEGA ZRAKA NIŽJA ALI ENAKA 12ºC. POVPREČNA TEMPERATURA ZUNANJEGA ZRAKA ZA EN DAN SE IZRAČUNA TAKO, DA SE SEŠTEJEJO TEMPERATURE OB 7. IN 14. URI TER DVAKRAT TEMPERATURA OB 21. URI, NATO PA DELIMO S 4. • ENERGIJSKO ŠTEVILO ( kWh/ m²leto ) JE GROBI POKAZATELJ ENERGIJSKE UČINKOVITOSTI OBSTOJEČIH STAVB. IZRAČUNAMO GA TAKO, DA CELOTNO RABO ENERGIJE V STAVBI DELIMO Z UPORABNO POVRŠINO BIVALNEGA PROSTORA V OBDOBJU ENEGA LETA. ENERGETSKI ZAKON ( EZ-1) • • • • DATUM SPREJETJA: 24.2.2014 UKAZ O RAZGLASITVI: 4.3.2014 ULRS ŠT. 17/ 2014, Z DNE 7.3.2014 ZAČETEK VELJAVNOSTI: 22.3.2014 • • • • • • • • NEKAJ CILJEV ZAKONA: ZANESLJIVA OSKRBA Z ENERGIJO, ZAGOTAVLJANJE KONKURENCE NA TRGU Z ENERGIJO, UČINKOVITA PRETVORBA ENERGIJE, ZMANJŠANJE RABE ENERGIJE, UČINKOVITA RABA ENERGIJE, VEČJA PROIZVODNJA IN RABA OBNOVLJIVIH VIROV ENERGIJE, PREHOD NA NIZKOOGLJIČNO DRUŽBO, VARSTVO POTROŠNIKOV KOT KONČNIH ODJEMALCEV ENERGIJE. PRAVILNIK O UČINKOVITI RABI ENERGIJE V STAVBAH ULRS Št.: 52, z dne, 30. 6. 2010 PO PRAVILNIKU O UČINKOVITI RABI ENERGIJE V STAVBAH IN TEHNIČNIH SMERNICAH ZA GRADITEV TSG-1-004 UČINKOVITA RABA ENERGIJE JE LETNA DOVEDENA ENERGIJA ZA DELOVANJE STAVBE ENAKA VSOTI DOVEDENIH ENERGIJ ZA: - OGREVANJE, - HLAJENJE, - PREZRAČEVANJE, - OVLAŽEVANJE, - PRIPRAVO TOPLE VODE, - RAZSVETLJAVO, - FOTONAPETOSTNEGA SISTEMA IN - POMOŽNE ENERGIJE ZA DELOVANJE SISTEMOV. OPTIMALNA IZBIRA KURILNE NAPRAVE KURILNO NAPRAVO IZBIRAMO ZA PRIHODNJIH 20 LET. ZA PRAVILNO IZBIRO JE POTREBNO OB SODELOVANJU INVESTITORJA IN PROJEKTANTA DOLOČITI PREDPOSTAVKE, KOT SO: - UGODNE BIVALNE IN DELOVNE RAZMERE, - EKONOMIČNA PORABA TOPLE VODE, - DOBRA TOPLOTNA ZAŠČITA OVOJA STAVBE, KER OMOGOČA IZBRATI KURILNO NAPRAVO MANJŠE MOČI, - KURILNA NAPRAVA NAJ BO NIZKOTEMPERATURNA ALI KONDENZACIJSKA, - GORILEC NAJ BO PRILAGOJEN KURILNI NAPRAVI, - DIMNIK NAJ BO PRILAGOJEN ENERGENTU, GORILCU IN KURILNI NAPRAVI, PO MOŽNOSTI LAS IZVEDBE, - ENERGENT NAJ BO OKOLJU PRIJAZEN, ČIM CENEJŠI IN VEDNO NA RAZPOLAGO, - ZRAČENJE IN PREZRAČEVANJE Z REKUPERACIJO TOPLOTE, OPTIMALNA IZBIRA KURILNE NAPRAVE - AVTOMATIZIRAN SISTEM OBRATOVANJA S ČASOVNIMI PREKINITVAMI OGREVANJA, - CENTRALNA REGULACIJA OGREVANJA PROSTOROV NAJ BO V ODVISNOSTI OD TEMPERATURE ZUNANJEGA ZRAKA, LOKALNA PA S TERMOSTATSKIMI VENTILI NA OGREVALIH, - VRSTA MATERIALA KURILNE NAPRAVE: LITO ŽELEZO, KOTELSKA PLOČEVINA, NERJAVEČA JEKLENA PLOČEVINA,…, - ZAGOTOVLJENA VSESTRANSKA VARNOST ( POŽARNA, ELEKTRIČNA, TERMIČNO VAROVALO, KI ZAPRE DOVOD ZRAKA V KURIŠČE PRI TEMPERATURI 85 ºC IN HLADILNI SISTEM, KI ODPRE DOTOK HLADNE VODE PRI TEMPERATURI 97 ºC,… ), - OKOLJU PRIJAZNA TEHNOLOGIJA IN MATERIALI Z MOŽNOSTJO RECIKLIRANJA, - ZAGOTOVLJEN SERVIS Z REZERVNIMI DELI, - MOŽNOST PRIDOBITVE SUBVENCIJE, KREDITOV IN SEJEMSKIH POPUSTOV. SEZNAMI USTREZNE OPREME SEZNAMI USTREZNE OPREME SO V JAVNEM RAZPISU EKO SKLADA 24SUB-OB14, KI JE ŽE ZAKLJUČEN, ZA: - SPREJEMNIKE SONČNE ENERGIJE, - KURILNE NAPRAVE NA LESNO BIOMASO ( POLENA, PELETE, SEKANCE ) - TOPLOTNE ČRPALKE ( ZRAK/ VODA, VODA/ VODA, ZEMLJA/ VODA ), - KONTAKTNO-IZOLACIJSKE FASADNE SISTEME – ETAG 004, - CENTRALNE IN LOKALNE PREZRAČEVALNE NAPRAVE Z Z VRAČANJEM TOPLOTE ODPADNEGA ZRAKA IN - ZUNANJE STAVBNO POHIŠTVO ( OKNA,…) – RAL MONTAŽA. NABAVA KURILNE NAPRAVE PRI NABAVI KURILNE NAPRAVE JE TREBA ZAHTEVATI: - ORIGINALNI RAČUN, - CERTIFIKATE ( IZKORISTEK, PRAŠNI DELCI, VREDNOST EMISIJ OGLJIKOVEGA MONOKSIDA, MOČ KOTLA, PRIKLJUČNA ELEKTRIČNA MOČ KOTLA, PROSTORNINA POLNILNEGA PROSTORA Z GORIVOM, PROSTORNINA VODNEGA TOPLOTNEGA ZBIRALNIKA,…), - NAVODILA ( MONTAŽNA SKICA, UPORABA, VZDRŽEVANJE, VARNOST,….), - GARANCIJA, - SERVIS, - SUBVENCIJE, SEJEMSKI POPUSTI. VGRADNJA KURILNE NAPRAVE KURILNO NAPRAVO NAJ VGRADI IN PREIZKUSI STROKOVNJAK Z REFERENCAMI PO NAČRTU STROJNIH INŠTALACIJ. POUDAREK NA POVEČANI VARNOSTI JE POTREBEN ZARADI PRISOTNOSTI: - VROČIH DELOV, - ENERGENTOV ( TRDNIH, TEKOČIH, PLINASTIH ), - ELEKTRIČNE ENERGIJE, - DIMNIH PLINOV, - TLAČNIH POSOD, - ELEKTRONIKE, - STRUPENIH SNOVI, KEMIKALIJ, ČISTILNIH SREDSTEV, - VODE,… Laddomat Shema vezave - laddomat Vir: http://www.boilerstoves.co.uk/laddomat-heat-charger.html DELOVANJE KURILNE NAPRAVE ZA PRAVILNO DELOVANJE OGREVALNEGA SISTEMA IN S TEM TUDI KURILNE NAPRAVE SKRBITA: - CENTRALNA REGULACIJA, PO MOŽNOSTI V ODVISNOSTI OD TEMPERATURE ZUNANJEGA ZRAKA IN - LOKALNA REGULACIJA S TERMOSTATSKIMI VENTILI NA OGREVALIH. ZRAK IZ PROSTORA NE RABITI ZA PROCES GORENJA V KURILNI NAPRAVI. PREPREČITI NASTANEK KONDENZA. KURILNA NAPRAVA MORA OGRETI NAJPREJ SEBE, POTEM PA OSTALI OGREVALNI SISTEM. VZDRŽEVANJE KURILNE NAPRAVE VZDRŽEVANJE KURILNE NAPRAVE NAJ BO PO NAVODILIH: - PROIZVAJALCA, - PRODAJALCA - SERVISNE IN - DIMNIKARSKE SLUŽBE. PRAVILNIK O OSKRBI MALIH KURILNIH NAPRAV, DIMNIH VODOV IN ZRAČNIKOV PRI OPRAVLJANJU JAVNE SLUŽBE IZVAJANJA MERITEV, PREGLEDOVANJA IN ČIŠČENJA KURILNIH NAPRAV, DIMNIH VODOV IN ZRAČNIKOV ( ULRS 128/ 2004, 30.11. 2004 ). PREGLEDOVANJE KURILNIH NAPRAV: - PRVI PREGLED ZARADI VPISA V EVIDENCO KURILNIH NAPRAV, - REDNI LETNI PREGLED, - IZREDNI PREGLED OPRAVI DIMNIKAR NA ZAHTEVO INŠPEKTORJA. UREDBA O EMISIJI SNOVI V ZRAK IZ MALIH IN SREDNJIH KURILNIH NAPRAV ULRS, št. 24/ 2013, z dne, 20.3.2013 MALA KURILNA NAPRAVA: < 1 MW VHODNE TOPLOTNE MOČI - TRDNO GORIVO < 5 MW VHODNE TOPLOTNE MOČI - TEKOČE GORIVO < 10 MW VHODNE TOPLOTNE MOČI - PLINASTO GORIVO SREDNJA KURILNA NAPRAVA: > 1 MW in < 50 MW VHODNE TOPLOTNE MOČI – TRDNO GORIVO > 5 MW in < 50 MW VHODNE TOPLOTNE MOČI – TEKOČE GORIVO > 10MW in < 50 MW VHODNE TOPLOTNE MOČI – PLINASTO GORIVO PRILOGE: - IZRAČUN TOPLOTNEGA IZKORISTKA KURILNE NAPRAVE - MEJNE VREDNOSTI EMISIJE SNOVI V ZRAK ZA ENOSOBNE KURILNE NAPRAVE - VSEBINA EMISIJSKE NALEPKE RAZGRADNJA KURILNE NAPRAVE MATERIALI, KI SO PRISOTNI V KURILNI NAPRAVI: - KOVINE: JEKLO, NERJAVEČE JEKLO, LITO ŽELEZO, BAKER, KOSITER,… - ŽIVO SREBRO,… - ENERGENTI: TRDNA, TEKOČA IN PLINASTA GORIVA,… - KEMIKALIJE: ČISTILNA SREDSTVA,… - BARVE, - SAJE,… - TOPLOTNA IZOLACIJA: KAMENA, STEKLENA VOLNA,… - STEKLO, - ELEKTRIČNE IZOLACIJE, - ŠAMOT, ( AZBEST ? ),… PRIMERI IZ PRAKSE • • • • • PREMOČNI KOTLI, VGRADNJA TOPLOTNE ČRPALKE PRED KOTEL NA ELKO, VGRADNJA LADOMATA, DA KOTEL OGREJE NAJPREJ SEBE IN NATO SISTEM, ŠUMENJE RADIATORJEV – VGRADNJA OBTOČNE ČRPALKE Z MANJŠO MOČJO, KONDENZ – GORENJE NA POLNO, LUKNJE V SPODNJIH VRATCIH DIMNIKA, MODEREN KOTEL NA ZEMELJSKI PLIN, KOMBINIRAN S SPREJEMNIKI SONČNE ENERGIJE JE POLETI, KO JE BILO VROČE VODE ŽE PREVEČ, ZAČEL DELOVATI ŠE NA PLIN. VZROK JE BIL HLAPENJE VODE, DVIGNILI SMO ODTOČNO CEV ZA ENO DEBELINO. Posledica žledu Lesna biomasa - drva Naloženo v kurišču Napačen začetek kurjenja Tri tedne po čiščenju Posledica preveč zaprte lopute Emisija v zrak Kondenzacijski kotel na plin AKTUALNO • • • ENERGETSKE NALEPKE ENERGETSKE IZKAZNICE STAVB KOREKCIJSKI FAKTOR ZA VEČSTANOVANJSKE STAVBE • SUBVENCIJE - EKO SKLAD - OBČINE - PETROL - ELEKTRO PODJETJE ZAKLJUČEK - - VSESTRANSKA VARNOST NAJ BO NENEHNO PRISOTNA, IZBIRA KURILNE NAPRAVE JE NAJPOMEMBNEJŠI, NAJZAHTEVNEJŠI IN NAJOBSEŽNEJŠI DEL INVESTICIJSKEGA CIKLUSA. VSE OSTALO JE LOGIČNO NADALJEVANJE, NE POZABIMO NA KOMBINACIJE Z BREZPLAČNO SONČNO ENERGIJO. HVALA ZA POZORNOST!
© Copyright 2024