Installation and Maintenance Manual MP700 Multi-Purpose LED

Installation and Maintenance Manual
MP700 Multi-Purpose LED
400 Watts
Thank you for purchasing a DAGR Industrial Lighting fixture – one of the most
durable LED fixtures on the market. Our lights have been engineered, tested and
certified to ensure optimum performance in the industry’s toughest
environments.
When installed, operated and maintained in accordance with product
specifications and instructions, your new LED fixture can be expected to provide
many years of reliable lighting performance and energy savings.
If you have any questions about the use and maintenance of your DAGR LED fixture, please contact us
toll-free at 1.866.203.0040 or email [email protected].
WARNING
WARNING
Important Safety Instructions
RISK OF FIRE AND/OR ELECTRIC SHOCK
•
This product should be installed and maintained by a
qualified Electrician ONLY, in accordance with all
applicable electrical codes.
•
Make sure the power is OFF before installing or
servicing. Never attempt to install or remove a fixture
from an energized circuit. Disconnect power at fuse or
circuit breaker before installing or servicing.
•
Proper grounding is required to ensure personal safety.
•
Inspect all units for damage prior to installation.
•
Do not alter, relocate or remove wiring, lamp holders,
ballast, drivers or any other electrical component.
•
Do not allow flammable or combustible materials to
accumulate on fixture.
•
Always wear appropriate personal protective equipment
(PPE) during installation, maintenance or handling.
Important Safety Instructions
HAZARDOUS LOCATIONS
•
Remove fixture from hazardous locations before
attempting any maintenance.
•
Do not return fixture to service in hazardous locations if
seals have been broken or product is damaged.
•
This fixture is made of aluminum and is not suitable for
use in underground mines where explosive atmospheres
may exist.
•
To maintain explosion proof integrity, make sure all
threads are fully engaged.
Product Unpacking
This fixture has been packed to avoid damage during transit. Inspect the fixture to confirm there is no damage prior
to installation. Do not install a damaged fixture or change fixture components.
DAGRlighting.com
1.866.203.0040
Page 1
MP700.1407.IM
May 2014
Installation and Maintenance Manual
MP700 Multi-Purpose LED
400 Watts
Operating Environments
LED technology differs from previous forms of lighting. The driver is capable of accepting a range of input voltages, but
requires a consistent supply of power. Drivers are able to withstand minor voltage drops and surges, but should not be
subject to frequent power fluctuations. The fixture should not be operated at voltage and current inputs below or
exceeding those listed under the unit’s operating parameters. Lighting circuits should be designed to ensure sufficient
and stable voltage and current are delivered to the unit.
Temperature limits for hazardous locations are listed on the certificate of conformance as well on the product label
attached to the fixture and presented later in this document. For optimal performance and longevity, the standard
operational environment of the fixture should not routinely exceed 35°C. Continuous operation at high ambient
temperatures will decrease the longevity of the driver. Under abnormally high ambient temperatures, the driver will
decrease power output as ambient temperatures approach and exceed 50oC and may go into protection mode.
Wiring
Wiring of this product must be performed by a qualified electrician and all electrical connections made in accordance
with the National Electrical Code, any applicable local code requirements and hazardous location requirements.
Luminaire Wire Guide
Phase (Live)
Neutral
Ground
Black
White
Green
Brown
Blue
Green and Yellow
USA and Canada
European Union (EU) (IEC 60446)
Typical Current Draw:
5A / 120VAC
Mounting
This fixture can be mounted using the mounting hardware provided. Do not mount in a fashion that puts strain on the
electrical cord or cord connector. Note: Fixture may become damaged and/or unstable if not installed properly.
Ensure that all mounting hardware is fully tightened and will not loosen. If mounted in areas subject to vibration,
ensure mounting methodology will not allow wear or shear on mounting hardware. A secondary method of securing
the fixture to the support can be employed as an additional safety measure.
Maintenance
Perform visual, electrical, and mechanical inspections on a regular basis. The environmental and operating conditions,
in conjunction with a preventive maintenance program, should be used to determine inspection frequency. We
recommend an Electrical Preventive Maintenance Program as described in the National Fire Protection Association
Bulletin NFPA No. 70B: Recommended Practice For Electrical Equipment Maintenance (www.nfpa.org).
To prevent heat build-up, remove dust from the LED housing. The lens should be cleaned periodically to ensure
continued lighting performance. Do not use an abrasive, strong alkaline or acid cleaner as damage may result.
DAGRlighting.com
1.866.203.0040
Page 2
MP700.1407.IM
May 2014
Installation and Maintenance Manual
MP700 Multi-Purpose LED
400 Watts
Warranty
Fixtures come with a 5-year warranty when installed in a fixed location, such as in a building. The product has a limited
1-year warranty when installed and used in any mobile application. Visit DAGRlighting.ca for full warranty details.
Product Dimensions (mm)
Unit Weight
13 kg
Units per Box
1
DAGRlighting.com
1.866.203.0040
This product consists of:
• Housing and heat sink
• Power supply
• LED arrays
• Cover plate with lens and reflector
• Mounting bracket (not shown)
• Electrical cord and cord connector
(not shown)
Page 3
MP700.1407.IM
May 2014
Installation and Maintenance Manual
MP700 Multi-Purpose LED
400 Watts
Mounting Assembly
Step 1 – Lay out materials.
Step 2 – Place the appropriate lock washer on each bolt,
followed by the flat washer.
Step 3 – On one side of the fixture, place a mounting plate onto
back of the fixture, followed by the mounting angle indicator.
Step 4 – Align all pieces and secure loosely with the appropriate
bolts.
Step 5 – Repeat step 3 on the opposite side of the fixture.
Step 6 – Loosely secure the mounting bracket onto the angle
indicators by placing a bolt through the center of the indicators
and securing directly to the bracket.
Step 7– Tighten bolts to secure mounting plate and angle
indicator to the housing.
Step 8– Adjust mounting bracket to the desired angle, and then
tighten center bolt as well as angle indicating bolt.
DAGRlighting.com
1.866.203.0040
Page 4
MP700.1407.IM
May 2014
Installation and Maintenance Manual
MP700 Multi-Purpose LED
400 Watts
Certification and Conformance
This product conforms to UL and CSA standards for LED luminaires.
Conformance certifications can be found at http://www.labtestcert.com/labtest/
Limitation of Liability
All statements, technical information and recommendations contained in this document are based on information and
test results we believe to be reliable. The accuracy or completeness thereof is not guaranteed. As conditions of use are
outside our control, the purchaser should determine the suitability of the product for his/her intended use and assumes
all risk and liability whatsoever in connection therewith.
NOTE: Product specifications and dimensions are subject to change without notice.
DAGRlighting.com
1.866.203.0040
Page 5
MP700.1407.IM
May 2014