EN www.seifertsystems.com DE OC 4305 OC 4308 OC 4309 OC 4310 OC 4315 EN EN General DE DE AlIgemein SoliTherm ComPact Outdoor Abmessungen / Dimensions Gewicht – Weight (Kg) Schutzart innen/aussen / Protection rating int. /ext. Kühlleistung / Cooling performance (DIN 3168) Kältemittel / Refrigerant Max. Betriebsdruck / Max. working pressure 33.7 33.7 36 650 x 315 x 260 mm IP 55 850 W (L35L35) R134a PS35 / PO30 bar 36 47.7 Max. Anlaufstrom (A) Max. start-up current (A) 6A 9.8 2.5 230V 50/60Hz 10 A 19.1 5.3 120V 50/60Hz 2x3.6 A 4.3 1.6 400V 2~ 2x3.6 A 4.3 1.4 460V 2~ 6A 10.1 3.8 230V 50/60Hz 16 A 20.5 6.4 120V 50/60Hz 2x3.6 A 4.5 2.4 400V 2~ 2x3.6 A 4.5 2.1 460V 2~ 10 A 15.5 3.2 230V 50/60Hz 16 A 29.8 6.7 120V 50/60Hz 2x3.6 A 4.9 2 400V 2~ 2x3.6 A 4.9 1.8 460V 2~ 10 A 15.9 3.2 230V 50/60Hz 16 A 30.2 6.7 120V 50/60Hz 2x3.6 A 5.1 2 400V 2~ 700 2x3.6 A 5.1 1.8 460V 2~ 800 10 A 21.2 5.1 230V 50/60Hz 880 16 A 39.4 9.6 120V 50/60Hz 880 2x6 A 5.3 2.6 400V 2~ 1,000 2x6 A 5.3 2.9 460V 2~ Nennstrom / Rated current (A) Sicherung – Fuse rating (T) 600 CE 300 m3/h CE 380 m3/h 550 m3/h 700 320 m3/h CE 200 m3/h 340 m3/h 550 DE Steuerung Max. Luftvolumenstrom / Air volume flow 700 CE 200 m3/h 350 m3/h 600 280 m3/h 700 R134a R134a 1.5 kW (L35L35) IP 55 980 x 395 x 260 mm 431532XX 550 39.7 431502XX 450 Umgebungskreislauf / Ambient air circuit Schrankkreislauf / Cabinet air circuit CE o 150 m3/h C) o C (20o o - 450 PS35 / PO30 bar R134a 1 kW (L35L35) IP 55 650 x 315 x 260 mm 431032XX 540 30 431002XX 410 Elektrische Anschlussdaten / Electrical data 30 430902XX 410 PS35 / PO30 bar R134a 750 W (L35L35) IP 55 650 x 315 x 260 mm 430832XX 410 27.7 430802XX 440 PS35 / PO30 bar R134a 550 W (L35L35) IP 55 650 x 315 x 260 mm 430532XX 370 27.7 430502XX Nennleistung (W) Power consumption (W) Nennspannung / Netzfrequenz / Voltage / Frequency 430932XX C) o C (20o o o C (20o o C) o C (20o o Zertifizierung / Certifications EN Controller The unit is equipped with an electronic temperature controller which regulates the - DE Fehlerbehebung Failure Condition Cause Solution Unit does not cool Internal fan does not work There is no power on the unit Verify power supply Internal fan needs to be replaced Replace internal fan Enclosure air temperature below setting temperature (St) Verify value of parameter St Door switch contact is open Verify door switch Controller does not work Replace controller Compressor motor electrical failure Verify external fan, verify ambient temperature, clean condenser Capacitor for compressor failed Replace capacitor Compressor works external fan does not work External fan needs to be replaced Replace external fan Compressor and fans (external and internal) work all the time Unit cooling undersized Enclosure needs a bigger cooling unit External fan and compressor work at intervals Thermal compressor protector triggered Verify ambient temperature, clean condenser Refrigerant leakage Contact dealer/service center Ambient air get into the enclosure Ensure door is closed, add a door switch and connect it to controller Enclosure IP degree minimum IP54 Seal openings on enclosure Damaged misplaced sealing strip Repair strip accordingly Internal fan works, external fan and compressor do not work. External and internal fan work, compressor does not work Enclosure over heating Excessive condensate Door enclosure closed Door enclosure closed Fehler Gerät kühlt nicht Kühlung unzureichend Zuviel Kondenswasserbildung Zustand Interner Lüfter arbeitet nicht. Ursache Keine Netzspannung am Gerät. Interner Lüfter muss ersetzt werden Interner Lüfter arbeitet, Schranktemperatur liegt Aussenlüfter und Verdichter unter der Eichtemperatur funktionieren nicht. des Thermostats. Abhilfe Stromversorgung untersuchen Internen Lüfter ersetzen Keine Gerätestörung. Zur Überprüfung der Testfunktionen den Eichpunkt des Thermostats soweit herunterstellen, dass Verdichter und Aussenlüfter anspringen. Danach den Eichpunkt wieder zurückstellen. Türkontaktschalter ist offen. Überprüfen Sie denn Türkontakt. Steuerung funktioniert Steuerung ersetzen. nicht. Aussen- und Innenlüfter Verdichtermotor hat elekAussenlüfter überprüfen, arbeiten, Verdichter arbeitet trischen Fehler. Umgebungstemperatur nicht. überprüfen, Verdichter reinigen. Kondensator des Verdich- Kondensator ersetzen. ters defekt Verdichter funktioniert, Aussenlüfter muss ersetzt Aussenlüfter muss ersetzt Aussenlüfter funktioniert werden. werden. nicht. Verdichter und beide Lüfter Kühlgerät zu klein (unterDas Kühlgerät durch ein (aussen / innen) arbeiten dimensioniert) für die im Gerät mit höherer Leistung ständig. Schaltschrank abgestrahlte ersetzen Wärme Aussenlüfter und Verdichter Wärmeschutzschalter im Umgebungstemperatur funktionieren in Intervallen. Inneren des Verdichters hat überprüfen, Verdichter angesprochen. reinigen Kühlmittel undicht. Bitte den Kundendienst kontaktieren Schaltschranktüre offen. Umgebungsluft gelangt ins Stellen Sie sicher das die Schaltschrankinnere. Türe geschlossen ist, fügen Sie einen Türkontaktschalter hinzu und verbinden Sie ihn mit der Steuerung. Schaltschranktüre Der Schutzgrad des Keine Gerätestörung. Öffgeschlossen. Schrankes ist kleiner als nungen im Schaltschrank IP54. wie z.B. Kabeldurchgänge hermetisch verschliessen. Die Dichtung zwischen Hermetisch verschließen. Schaltschrank und Kühlgerät ist nicht richtig angebracht. Doc. No. 597700002 Rev 1.5 04/2014 EN Troubleshooting
© Copyright 2024