Ellipse® Pitot Tube Meter AHL-GD Differential Pressure Flow Meter ERS MET FLOW W/O L WAL /β MOD ID DIA/ CAP SCH/ DP TAG PTT-UM-00327-EN-02 (April 2014) User Manual Ellipse® Pitot Tube Meter, AHL-GD Differential Pressure Flow Meter CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Pipe Orientation and Sensor Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Installation Instructions, Single Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Installation Instructions, Double Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Location Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Flow Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Page ii April 2014 User Manual INTRODUCTION The Preso patented elliptical design outperforms and provides greater accuracy than traditional differential pressure flow measurement devices. This differential pressure flow meter is designed with a series of ports facing the upstream velocity pressures, as well as flow sensing ports strategically located ahead of the trailing edge flow separation. The multi-ported, self-averaging flow element consists of an elliptical shape with two independent flow sensing chambers. The impact velocity sensing holes (high pressure) are located along the leading edge and the true static sensing holes (low pressure) are on the exterior probe side. Model AHL-GD comes with instrument shutoff valves with provisions to accept a transmitter or direct indicating meter. True Static Sensing Holes Impact Velocity Sensing Holes Figure 1: AHL-GD Ellipse pressure sensing holes SPECIFICATIONS Applications Air, liquids and gases Pipe Sizes 2…72 in. (50…1829 mm) Pressure 800 psi (5515 kPa) maximum Temperature 800° F (426° C) maximum Accuracy ±0.75% of reading Turndown Ratio 17:1 with no vacuum effect Standard Components T-type head, 316 SS 1/4 in. or 1/2 in. FNPT connection CS 3000 lb. thread fitting, ASTM A105 316/316L SS Ellipse sensor Instrument valves (2 per sensor), 1/4 in. or 1/2 in., CS 316 SS ID tag with wire 150 lb. 316/316L SS sensor flange CS packing chamber with molythane or graphite packing gland CS packing chamber flange, 150 lb. with SS cap 316 SS isolation ball valve, NPT threaded CS threaded nuts and bolts CS nipples, schedule 40 Reynolds Number Greater than 75,000 maintains most accurate flow measurements Less than 75,000 consult factory for estimated results Resonance Less than 0.8 but greater than 1.2. If greater than 0.8, use double support. System shutdown is required when the double support option is used. Select larger diameter ellipse to avoid double support. Table 1: AHL-GD specifications April 2014 Page 3 Ellipse® Pitot Tube Meter, AHL-GD Differential Pressure Flow Meter PIPE ORIENTATION AND SENSOR MOUNTING H FLOW L FLOW METERS W/O MOD/β DIA/ID CAP DP TAG FLOW METERS W/O MOD/β DIA/ID CAP DP TAG SCH/WALL SCH/WALL 10° 10° Field Weld Lock Nuts Field Weld 10° 10° FLOW METERS W/O MOD/β DIA/ID CAP DP TAG H FLOW FLOW METERS W/O MOD/β DIA/ID CAP DP TAG SCH/WALL Air, Gas, or Liquid with Proper Bleeding SCH/WALL L Liquid Figure 2: Horizontal pipe installation FLOW FLOW or 5° Max. 5° Max. Field Weld MOD/β DIA/ID CAP DP TAG FLOW METERS W/O Liquid, Air and Gas Note: SCH/WALL W F L O Illustration represents installation for downward flow. Sensor Alignment Note: Probe alignment applies to all horizontaland vertical installations. Figure 3: Vertical pipe installation and sensor alignment Page 4 April 2014 User Manual INSTALLATION INSTRUCTIONS, SINGLE SUPPORT 1. Choose the proper location to install the AHL-GD Differential Pressure Flow Meter using AGA/ASME standards (or equivalent). Refer to the location diagrams Figure 2, Figure 5 and Figure 6. 2. Grind the surface of the pipe where the AHL-GD Differential Pressure Flow Meter is to be inserted to provide a clean area for welding. 3. Weld the supplied thread-o-let to the pipe using standard codes for your application (1/16 in. weld gap recommended). Take care to protect the threads during the welding process. 4. Install the close nipple by threading it into the weld connector. Next, install the supplied 3-piece isolating ball valve. 5. Mount the high pressure drilling machine onto the ball valve. Open the ball valve. Drill a hole through the pipe wall according to Table 2. Model/Sensor Weld Connector Drill Bit AHL-GD (7⁄8 in.) 1-1/4 in. 1-1�8 in. AHL-GD (1-1/4 in.) 1-1/2 in. 1-3�8 in. Table 2: Single support drill bit size NNOTE: There is no need for a drilling machine if it is not a hot tap installation or if the system is not pressurized. 6. Having drilled through the pipe, withdraw the drill bit through the isolating ball valve. Once the drill bit has been withdrawn, close the ball valve and dismantle the drilling machine. Ensure that there is no leakage at the valve and close nipple connections. The ball valve is to remain completely closed until step 9. 7. Install the cage nipple assembly and packing gland with the threaded rods assembly by threading it into the isolating ball valve. Align the arrow on the sensor head with the direction of flow. See Figure 4 and Figure 5. 8. Install the instrument valves (optional) at the pressure connections located on the AHL-GD Differential Pressure Flow Meter sensor head. Ensure that the valves are fully closed before proceeding. H FLOW FLOW METERS W/O MOD/β DIA/ID CAP DP TAG SCH/WALL L H FLOW L FLOW METERS W/O SCH/WALL Field Weld Figure 4: Flow indication arrow 9. Open the isolating ball valve. Insert the AHL-GD Differential Pressure Flow Meter sensor into the pipe until it reaches the opposite pipe wall. This should be done by turning the threaded insertion rods clockwise using a wrench. 10.Connect the instrument lines to the sensor head valves. In turn, connect these lines to a gage or transmitter. April 2014 Page 5 Ellipse® Pitot Tube Meter, AHL-GD Differential Pressure Flow Meter INSTALLATION INSTRUCTIONS, DOUBLE SUPPORT 1. Follow steps 1 through 6 in the single support section. At 180° from and on the same plane as the previously drilled hole, grind the surface of the pipe to provide a clean area for welding. Drill a hole and de-burr, especially on the inside of the pipe. The hole used for the double support should be sized according to Table 3. Model/Sensor Weld Connector Drill Bit AHL-GD (7⁄8 in.) 1/8 in. 3/8 in. AHL-GD(1-1/4 in.) 1 in. 7⁄8 in. Table 3: Double support drill bit size 2. Weld the double support thread-o-let making sure that it is centered with the drilled hole (1/16 in. weld gap recommended). 3. Install the AHL-GD Differential Pressure Flow Meter sensor through the two holes. Make sure that the double support pin passes through the guide ring. See Figure 5. Ellipse Sensor Double Support Pin Guide Ring Figure 5: Double support installation 4. Align the arrow located on the sensor head in the direction of flow as shown in Figure 4. 5. Ensure that the AHL-GD Differential Pressure Flow Meter is in the correct orientation and spans the inside of the pipe. Tighten the threaded insertion rods until the sensor reaches the other end of the pipe. 6. Install the plug into the end of the double support thread-o-let. Tighten the plug to prevent leakage. Page 6 April 2014 User Manual LOCATION INSTRUCTIONS Accuracy is affected by the piping configurations due to the disturbances of the flow profile. A fully developed symmetrical flow profile is achieved with the minimum upstream and downstream recommended lengths. DISTANCES ARE EXPRESSED IN NUMBER OF NOMINAL PIPE DIAMETERS THROTTLED VALVE OR REGULATOR 27 4 H TWO ELBOWS IN DIFFERENT PLANES 24 4 L H Preso FLOW METERS W/O MOD/β DIA/ID CAP DP TAG SCH/WALL FLOW 11 4 5 H 10 5 FLOW 9 MOD/β DIA/ID CAP DP TAG Preso FLOW H L Preso FLOW METERS W/O L FLOW METERS W/O SCH/WALL Preso TWO ELBOWS IN THE SAME PLANE 11 3 4 H H SCH/WALL Straightening Vane CHANGE IN PIPE SIZE MOD/β DIA/ID CAP DP TAG L FLOW METERS W/O MOD/β DIA/ID CAP DP TAG 2 4 4 5 Preso SCH/WALL Straightening Vane 9 Preso H L FLOW METERS W/O MOD/β DIA/ID CAP DP TAG 2 SCH/WALL FLOW Regulator or Partially Closed Valve 6 L FLOW METERS W/O MOD/β DIA/ID CAP DP TAG SCH/WALL L FLOW METERS W/O MOD/β DIA/ID CAP DP TAG SCH/WALL Preso FLOW FLOW 4 10 FLOW 4 6 4 L FLOW METERS W/O SCH/WALL H FLOW Straightening Vane L FLOW METERS W/O L Preso SCH/WALL 2 2 2 3 5 MOD/β DIA/ID CAP DP TAG FLOW METERS W/O MOD/β DIA/ID CAP DP TAG Preso 9 4 4 6 H H MOD/β DIA/ID CAP DP TAG 10 SCH/WALL Preso FLOW Straightening Vane FLOW Straightening Vane A SINGLE ELBOW 7 3 H L FLOW METERS W/O MOD/β DIA/ID CAP DP TAG SCH/WALL Preso FLOW 5 3 3 2 H L FLOW METERS W/O MOD/β DIA/ID CAP DP TAG SCH/WALL Preso 2 FLOW Straightening Vane Figure 6: Location instructions April 2014 Page 7 FLOW CURVE 4 3 2 12" 16" 20" 14" 18" 24" 30" WATER 60 °F 5 6 789 100000 5" 6" 2 3 8" 4 10" 5 6 789 10000 USGPM 2" 2 2.5" 3 4 3" 3.5" 4" 5 6 789 1000 5 6 789 1 .2 .3 .4 2 1 .9 .8 .7 .6 .5 3 2 4 3 4 5 6 10 9 8 7 NOTE: 2…10 in. CURVES ARE FOR SCHEDULE 40 PIPE 12 in. AND ABOVE ARE FOR SCHEDULE STANDARD PIPE 2 20 – ES O 40 30 ∆P INC H 2 ANNULAR ELLIPSE ® 10 OF H 100 90 80 70 60 50 3 4 5 6 789 100 Figure 7: Pressure drops Control. Manage. Optimize. PRESO is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved. www.badgermeter.com The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0 Europe, Middle East Branch Office | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503 Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411 Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01 Asia Pacific | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836 China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412 Legacy Document Number: 10-PTT-UM-00301
© Copyright 2024