Measuring current transformers of the W…AB(P) series W-AB(P)_D00074_00_D_XXEN/05.2014 Measuring current transformers of the W…AB(P) series Product description Measuring current transformers of the W…-AB series are measuring current transformers which in combination with devices of the RCMA420/423 resp. RCMS460/490 series convert AC and DC currents into evaluable measurement signals. Connection to the respective devices is via a five-wire or six-wire cable. The CTs can be used in DC, AC, and 3(N) AC systems. If the measuring current transformers are to be connected to an RCMS460/490 system, one AN420 or AN110 power supply unit is required for six measuring current transformers each. The measuring current transformers of the W35ABP and W60ABP series feature an integrated Mumetal shield. Standards W60AB measuring current transformer Device features • W20AB…W60AB for AC/DC sensitive RCMA420 residual current monitors • W20AB…W210AB for RCMS460/490 residual current monitoring systems or for RCMA423 residual current monitors • W35ABP and W60ABP for RCMS460/490 and for RCMA420/423 residual current monitors. For use in systems where shortterm load currents are likely to occur. Approvals 2 W-AB(P)_D00074_00_D_XXEN/05.2014 W…AB series measuring current transformers comply with the device standards: IEC 61869-1. Installation instructions • Make sure that all live conductors are routed through the measuring current transformer • Do not route shielded conductors through the measuring current transformer • As a general principle, the PE conductor und low-resistance conductor loops must not be passed through the measuring current transformer! Otherwise the applied AC/DC sensitive measurement technique can result in high currents being induced into the conductor loop. W…AB(P) series measuring current transformers Wiring diagram I(∆n) ≤ 500 mA W…AB(P) I(∆n) ≤ 500 mA I(∆n) > 500 mA Connection to the RCMS460/490 residual current monitor using the WXS-… connecting cable. W…AB(P) I(∆n) > 500 mA Connection to the RCMA420/423 residual current monitor using the WX-… connecting cable. Colour coding for WXS… and WX…: k = yellow, l = green, -12 V = black, GND = brown, +12 V = red, Test (T) = orange W-AB(P)_D00074_00_D_XXEN/05.20143 W…AB(P) series measuring current transformers Technical data Ordering information Insulation coordination acc. to IEC 60664-1/IEC 60664-3 Rated voltage Rated impulse voltage/pollution degree 800 V 8 kV/3 Supply voltage Supply voltage US Operating range of US Power consumption DC ± 12 V 0.95…1.05 x US ≤ 2.5 VA CT circuit Rated primary residual current W20AB Rated primary residual current W35AB(P)…W120AB Rated primary residual current W210AB Rated continuous thermal current Icth Rated short-time thermal current Ith Rated dynamic current Idyn 10…500 mA 10 mA…10 A 300 mA…10 A 40 A 2.4 kA/1 s 6.0 kA/40 ms Mounting Inside diameter Type Art. No. 20 mm 120 mm 210 mm W20AB W35AB W35ABP W60AB W60ABP W120AB W210AB B 9808 0008 B 9808 0016 B 9808 0051 B 9808 0026 B 9808 0052 B 9808 0041 B 9808 0040 Length Type Art. No. 1m 2.5 m 5m 10 m 1m 2.5 m 5m 10 m WX-100 WX-250 WX-500 WX-1000 WXS-100 WXS-250 WXS-500 WXS-1000 B 9808 0503 B 9808 0504 B 9808 0505 B 9808 0511 B 9808 0506 B 9808 0507 B 9808 0508 B 9808 0509 35 mm Mounting brackets, DIN rail 60 mm Mounting brackets Connecting wires For device Environment/EMC EMC IEC 62020 Operating temperature -10…+55 °C Climatic class acc. to IEC 60721 Stationary use (IEC 60721-3-3) 3K5 (except condensation and formation of ice) Transport (IEC 60721-3-2) 2K5 (except condensation and formation of ice) Long-time storage (IEC 60721-3-1) 1K5 (except condensation and formation of ice) Classification of mechanical conditions IEC 60721 Stationary use (IEC 60721-3-3) 3M4 Transport (IEC 60721-3-2) 2M2 Long-time storage (IEC 60721-3-1) 1M3 RCMA420/423 RCMS460/490 Control cable LiYY flexible, 6 x AWG 20 (6 x 0.56 mm²), approved by UL 2464 Connection Type of connection plug-in connectors Connection RCMA/RCMS measuring current transformers see table “connecting cables” Other Degree of protection, internal components (IEC 60529) IP40 Degree of protection, terminals (IEC 60529) IP20 Screw mounting fillister head screw M5 acc. to DIN7985 DIN rail mounting (W20AB… W60AB(P) only) Snap-on mounting Flammability class UL94 V-HB Documentation number D00074 Accessories Type designation For device Art. No. Snap-on mounting W20AB, W35AB(P) W60AB(P) B 9808 0501 B 9808 0502 Suitable system components Type designation Supply voltage US Type Art. No. AC 16…72 V/DC 9,6…94 V DC, AC 42…66 Hz AN420-1 B 7405 3099 AC/DC 70…276 V DC, AC 42…460 Hz AN420-2 B 9405 3100 AC 20…60 V; DC 18…72 V DC, AC 50…60 Hz AN110-1 B 9405 3101 AC 90…264 V; DC 100…353 V DC, AC 50…60 Hz AN110-2 B 9405 3102 Power supply units Selection list 4 W-AB(P)_D00074_00_D_XXEN/05.2014 Type RCMA420 W20AB W35AB(P) W60AB(P) W120AB W210AB – – RCMA423 RCMS460/490 W…AB(P) series measuring current transformers Dimension diagram Dimensions (mm) Type A W20AB W35AB(P) W60AB(P) W120AB W210AB 30 30 37 37 45 B C D 56.3 50 76.4 79.2 62 99.5 116.4 79 135 191.5 116.5 210 304.5 173 323 E F 48.5 ø 20 55 ø 35 67 ø 60 67 ø 120 80 ø 210 G Weight H 29.8 16.4 41.7 20 60.4 24 98 33.5 154.5 45 180 g 350 g 570 g 1920 g 5800 g Tolerance: ± 0.5 mm Mounting details Snap-on mounting on DIN rail, for vertical or horizontal mounting: W20AB, W35AB(P), W60AB(P) Screw mounting with mounting brackets: W20AB, W35AB(P), W60AB(P) Screw mounting: W120AB, W210AB Dimensions (mm) Type Dimensions (mm) A B C D 49 31.4 65 18.6 W35 (mounting with 2 mounting brackets diagonal) 49 49.8 65 12.1 W35AB(P) (mounting with 2 mounting brackets diagonal) 56 66 72 17.7 W60AB(P) (mounting with 3 mounting brackets diagonal) 81 103 90.6 65 W120AB (screw mounting) 98 180 117.1 83 W210AB (screw mounting) Dimensions in mm Tolerance for screw mounting with mounting brackets: ± 1.5 mm Type A B W20AB W35AB(P) W60AB(P) 43.5 43.5 50 32 32 39 W-AB(P)_D00074_00_D_XXEN/05.20145 BENDER Group W-AB(P)_D00074_00_D_XXEN / 05.2014 / Schw / pdf / © Bender GmbH & Co. KG, Germany – Subject to change! The specified standards take into account the version that was valid at the time of printing. Bender GmbH & Co. KG P.O. Box 1161 • 35301 Gruenberg • Germany Londorfer Strasse 65 • 35305 Gruenberg • Germany Tel.: +49 6401 807-0 • Fax: +49 6401 807-259 E-Mail: [email protected] • www.bender.de
© Copyright 2024