HYGIENE AND DISINFECTION PROGRAM FOR DENTAL SUCTION SYSTEMS Product

HYGIENE AND DISINFECTION
PROGRAM FOR DENTAL
SUCTION SYSTEMS
Product
Puli-Jet Plus (New)
Concentrated disinfectantdtergent for aspirators
Puli-Jet Plus
Concentrated disinfectantdetergent for aspirators
Puli-Jet Classic
Sanitizing detergent for
aspirators
Disinfectant antifoam
tablets
Disinfectant antifoam tablets
for aspirators
Sanitizing antifoam tablets
Sanitizing antifoam tablets
for aspiration
Application
When to use
How to use
Range of Action
Single surgery and
centralized aspiration
systems
At the end of the working
day, after surgical
interventions on high
infection risk patients, for a
detergent-disinfectant wash.
For a cleaning-disinfectant
action: prepare a solution at
0.8% in warm water (about
50C).
For a cleaning -sanitizing
action: prepare a solution
on 0.4% in warm water
(about 50C).
Suck from the Pulse Cleaner
through the equipment.
With 1 litre of product it is
possible to obtain 250 litres
of sanitizing solution at 0.4%
and 125 litres of disinfectant
solution at 0.8%.
Let it work during the night
or for at least 1 hour.
Detergent disinfectant:
Single surgery and
centralized aspiration
systems.
At the end of the working
day, after surgical
interventions on high
infection risk patients, for a
detergent-disinfectant wash.
For a cleaning-disinfectant
action: prepare a solution at
0.8% in warm water (about
50C).
For a cleaning -sanitizing
action: prepare a solution
on 0.4% in warm water
(about 50C).
Suck from the Pulse Cleaner
through the equipment.
With 1 litre of product it is
possible to obtain 250 litres
of sanitizing solution at 0.4%
and 125 litres of disinfectant
solution at 0.8%.
Let it work during the night
or for at least 1 hour.
Detergent disinfectant:
Single surgery and
centralized aspiration
systems.
Midworking day, after
surgical interventions. for a
detergent-sanitizing wash.
Prepare a solution at 5% in
warm water (about 50C).
Suck from the Pulse Cleaner
through the equipment.
With 1 litre of Puli-Jet
Classic it is possible to
obtain 20 litres of solution
at 5%.
Detergent sanitizingantibacterial
Single surgery and
centralized aspiration
systems.
At the end of every working
day, after cleaning and
disinfection.
At the end of every working
day, after cleaning, place 1
or 2 tablets in the first filter:
when aspirated, the liquid
will take up the right quantity
of product.
Antifoam Disinfectant:
Single surgery and
centralized aspiration
systems.
At the end of every working
day, after cleaning and
disinfection.
At the end of every working
day, after cleaning, place 1
or 2 tablets in the first filter:
when aspirated, the liquid
will take up the right quantity
of product.
Antifoam Disinfectant:
- Bactericide
- Fungicide
- Tuberculicide
- Bactericide
- Fungicide
- Tuberculicide
- Virucide
- Bactericide
- Candidicide
- Bactericide
- Candidicide
Certificates and ref. rules
CE 0434
Class 11a-Medical Device
Precautions
Use protective gloves when
preparing the solution.
UNI EN 13727:2004
UNI EN 13624:2004
PrEN 14563:2002
CE 0434
Class 11a-Medical
Device
Use protective gloves when
preparing the solution.
UNI EN 13727:2004
UNI EN 13624:2004
PrEN 14563:2005
UNI EN 14476:2007
Use protective gloves when
preparing the solution.
CE 0434
Class 11a-Medical Device
UNI EN 13727:2004
UNI EN 13624:2004
Do not remove the
protective film: it dissolves
in the aspirated liquid. For
small filters: remove the film,
then break the tablet in half
by pressing along the precut groove. Use protective
gloves.
Do not remove the
protective film: it dissolves
in the aspirated liquid. For
small filters: remove the film,
then break the tablet in half
by pressing along the precut groove. Use protective
gloves.
APPLICATION OF THE CHEMICAL PRODUCTS
FOR THE HYGIENE OF THE DENTAL SURGERY
Product
Fast & Sterile 3
High-Level Disinfectant /
sterilizer for
surgical
impressions
Fast & Sterile 3
Impressions
High-Level disinfectant
sterilizer for dental
impressions
Quick Sterile
Chemical sterilizer
for surgical
instruments
Quick Sterile Indicator
Accessory to verify the
MEC
Eco-Jet 1 Tissue
High-level disinfectant
wet wipes
Application
Surgical instruments that
cannto be treated with a
thermo-disinfector
On dental impressions
prior to sending them to
the laboratory
Surgical instruments
which cannot be sterilized
thermally
When to use
On clean and dry surgical
instruments
On dental impressions just
produced
On clean and dry surgical
instruments
Quick sterile sterilizing
solutions
Before sterilizing
treatments with Quick
Sterile reused or freshly
prepared solutions
Flat and smooth
surfaces, handles, etc
After every intervention
How to use
Characteristics
Pour the entire contents of
all 3 packets into 2.5 litres
of water. After 10 minutes
submerge the instruments
completely.
- The solution remains
active for a period of 36
hours
Pour the entire contents
of all 3 packets into 1 litre
of water. After 10 minutes
submerge the instruments
completely for 10/15
minutes.
- The solution remains
active for a period of 36
hours
Dilute at 1.5% (activity
time: 8 hours) or 6%
(activity time: 4 hours).
Dip the instruments
completely.
Aspirate the fixed quantity
of liquid into the syringe,
then compare the colour of
the liquid.
- Handy
- Rapid
- Cheap
- Wipe clean with a
gentle pressure the
surface to be treated.
CE 0434
- Bactericide within 10’
- Fungicide within 10’
- Tuberculocide within 15’
- Virucide within 10’
- Sporicidal within 15’
CE 0434
- Non-corrosivity
Diluted at 6%:
CE 0434
- Absence of harmful
vapours
- Bactericide within 5’
- Fungicide within 5’
- Tuberculocide within 5’
- Virucide within 5’
- Sporicidal within 4h
UNI EN 13727, UNI EN 14561, UNI
EN 13624, UNI EN 14562, UNI EN
14348, Pr EN 14563, UNI EN 14476,
UNI EN 13704, AFNOR NF T 72-190
- Non-corrosive, nonstaining
- Non-corrosive, nonstaining, it does not deform
dental impressions based
on alginates, polyester,
silicone and elastomer
High-level
disinfectant
-detergent
Irregular, rough or
difficult to reach sufaces
After every intervention
Ready-to-use:
- Spray onto the surface
from 20/30 cm
Disinfectant for
instruments
after use
AC Net
Detergent for the
cleaning of
autoclave
chambers
Aqua Plus
It prevents both
biofilm growth
and cross
infections
Lubri-Jet Spray
Lubricant
Lubri-Jet Drop
Lubricant
Protective
Hand Cream
UNI EN 14563, UNI EN 13704, UNI
EN 1276, UNI EN 1650, UNI EN
14476
CE 0434
Detergent disinfectant:
CE 0434
- Bactericide (within less
than 5’)
- Virucide (within less
than 15’)
- Fungicide (within less
than 15’)
- Tuberculocide (within
less than 5’)
UNI EN 1650, UNI EN 13713, UNI
EN 14476, UNI EN 13697 (HIV,
HBV, HCV), UNI EN 14348, Skin
Patch Test
Cool, flower-scented
perfume.
Detergent disinfectant:
CE 0434
- Bactericide (within less
than 5’)
- Virucide (within less
than 15’)
- Fungicide (within less
than 15’)
- Tuberculocide (within
less than 5’)
UNI EN 1650, UNI EN 13713, UNI
EN 14476, UNI EN 13697 (HIV,
HBV, HCV), UNI EN 14348, Skin
Patch Test
- Non corrosive
Diluted at 3%:
CE 0434
- Absence of harmful
vapours
- Bactericide within 5’
- Fungicide within 10’
- Tuberculocide within 5’
- Virucide within 5’
UNI EN 13727, UNI EN 14561,
UNI EN 13624, UNI EN 14562,
UNI EN 14348, pr EN 14563, UNI
EN 14476
- Bactericide within 10’
- Fungicide within 60’
- Tuberculocide within
10’
- Legionellicide within 5’
CE 0434
- Let it soak for 5 minutes
- Wipe with a dry sterile
cloth
Eco-Jet 2
UNI EN 14563, UNI EN 13704, UNI
EN 1276, UNI EN 1650, UNI EN
14476, UNI EN 13697
Cool, flower-scented
perfume. It leaves no
residue
- Let it work for 5
minutes, self-drying
Eco-Jet 1 Spray
Certificates and ref. rules
- Bactericide within 10’
- Fungicide within 10’
- Tuberculocide within 15’
- Virucide within 10’
- Sporicidal within 15’
- Rapid activity time (1/2 of
the glutaraldehyde activity
time)
Ready-to-use:
Range of Action
Precautions
We suggest to keep the
disinfecting solution in a
covered basin. After 2 days
from the activation, the
solution can be aspirated
into the suction system.
We suggest to keep the
disinfecting solution in a
covered basin. After 2 days
from the activation, the
solution can be aspirated
into the suction system.
Verify the minimum
effective concentration
(MEC). Wear gloves. Carry
out preliminary test on the
instruments. Wipe off any
splashes immediately.
Do not use after the expiry
date. To be used with
Quick Sterile only.
It is generally safe on
hands. It can be used
without wearing gloves.
It has been tested
on many materials.
As a precaution, we
recommend carrying out
a preliminary test on a
part which is not in sight.
It is generally safe on
hands. It can be used
without wearing gloves.
It has been tested
on many materials.
As a precaution, we
recommend carrying out
a preliminary test on a
part which is not in sight.
Used instruments,
before cleaning and
sterilization cycle
Immediately after use
and before cleaning
Dilute at 1.5% (activity
time: 1h) or 3% (activity
time: 5-10’). Dip the
instruments completely.
Stainless steel medical
autoclaves
When needed
Spray onto the surface to
be treated, wipe clean,
rinse with water and dry.
Dental unit water piping
(DUW)
- Between one treatment
and the other
- During the night, weekend, etc
Diluted at 4%:
Fill the water circuit with
the solution and let it
work for at least 5/10
minutes.
Safe on DUWs materials
Surfaces exposed to
rubbing (rubber o-rings,
forceps, scissors, etc)
When needed. Before
the thermal sterilization
cycle, if required
On clean and dry
surfaces
Spray version for the
treatment of surfaces.
Not flammable. Dust
repellent.
Avoid leaks and wipe off
any excess.
Surfaces exposed to
rubbing (rubber o-rings,
forceps, scissors, etc)
When needed. Before
the thermal sterilization
cycle, if required
On clean and dry
surfaces
Phial with reclosable
drop dispenser.
Avoid leaks and wipe off
any excess. Do not spray
near an open flame.
Avoid inhaling and avoid
eye area.
Hands
After every washing or in
case of need.
Apply a minimum
quantity of cream (0.3g
at a time), then rub in
delicately until absorbed.
It contains dermatophile
oils which protect the
skin from dehydration
and reddening caused
by frequent use of
latex gloves. Rapidly
absorbed.
Do not use in excess.
UNI EN 13727, UNI EN 13624,
UNI EN 14348, Pr EN 13623
Wear gloves. Carry out
a preliminary test on the
instruments. Wipe off any
splashes immediately.
Check if the dental unit is
fitted with an automatic
disinfection system.
For further information, please contact
Cattani ESAM UK Limited, 21a Harris Business Park, Hanbury Road, Stoke Prior, Bromsgrove, Worcestershire, B60 4DJ
E S A M
U.K. LIMITED
t: 01527 877997
f: 01527 839799
e: [email protected]
w: www.cattaniesam.co.uk