Drive Systems for Hazardous Areas

Drive Systems for Hazardous Areas
• ATEX certified
• Safedrive® - Safety Brake incorporated
• Range of output speeds and torques
• Horizontal or vertical mounting
• Hollow shaft worm drive gear with directly
driven limit switches
• Controls available for both normal and
automatic operation.
About ATEX
Under the Dangerous Substances and
Explosive Atmosphere Regulations
2002 (DSEAR), it is an employer’s
responsibility to protect both their staff
and the public from risk to their safety
from fire and explosion.
However, it is the responsibility of
the door manufacturer to ensure
that any equipment that is sited in a
potentially hazardous area complies
with the “ATEX” directive, ensuring
any potential sources of ignition are
eliminated. Conformity with the ATEX
Model
directive calls for the employer or
owner of the premises to prepare a risk
assessment for the site, detailing the
type of hazardous material or the level
of protection required.
Application
The GfA range of drives and controls
are suitable for installation in different
hazardous areas such as refineries,
distilleries, sewage treatment works and
paint spray booths. We offer a range of
drives for rolling shutter and sectional
doors, both sprung and unsprung, control
panels and accessories.
The control panels offer the standard
open, stop and close operations but
can incorporate special functions for
specific requirements such as Shootbolt
Interlocks or automatic door operation.
For specific requirements please contact
the sales team for further details.
Assistance
Members of our sales team are qualified in
‘Hazardous Area Equipment, Legislation &
Safe Practice’ and are available to provide
assistance on equipment selection.
Ranger 90
Ranger 91
Safedrive 25/15
Safedrive 40/15
Safedrive 80/12
Type of Protection
Ex-e Increased
Safety
T3
Gas
Dust
II 2G IIC Ex e T3 Gb
II 2D IIC Ex e T190oC Db
II 2G IIC Ex e T3 Gb
II 2D IIC Ex e T190oC Db
II 2G IIC Ex e T3 Gb
II 2D IIC Ex e T190oC Db
II 2G IIC Ex e T3 Gb
II 2D IIC Ex e T190oC Db
–
Type of Protection
Ex-de
Flameproof
enclosure
T3
Gas
Dust
–
–
II 2G IIC Ex de T3 Gb
II 2D IIC Ex de T190oC Db
II 2G IIC Ex de T3 Gb
II 2D IIC Ex de T190oC Db
–
Type of Protection
Ex-de
Flameproof
enclosure
T4
Gas
II 2G IIC Ex de T4 Gb
Dust II 2D IIC Ex de T130oC Db
II 2G IIC Ex de T4 Gb
II 2D IIC Ex de T130oC Db
II 2G IIC Ex de T4 Gb
II 2D IIC Ex de T130oC Db
II 2G IIC Ex de T4 Gb
II 2D IIC Ex de T130oC Db
II 2G IIC Ex de T4 Gb
II 2D IIC Ex de T130oC Db
800
Output Torque
Nm
90
90
250
400
Output Speed
rpm
24
24
15
15
12
Motor power
kW
0.37
0.37
1.1
1.1
1.1
Supply Voltage
V
400v ~3
400v ~3
400v ~3
400v ~3
400v ~3
Supply Frequency
Hz
50
50
50
50
50
1.1
1.1
2.9
2.9
–
1.2
1.2
2.7
2.7
2.7
20
20
20
16
12
40
20
20
20
20
IP65
IP65
IP65
IP65
IP65
16
16
32
32
–
–
–
34
34
–
17
17
36
36
52
Current
Ex-e
Ex-de
Max Cycles per hour
A
H-1
Limit Switch Range
Protection
Ex-e
Weight
Ex-de T3
Ex-de T4
Kg
GA25/15 & GA40/15 - Ex-e/Ex-de
170
4
5
L2
2
B
ØD
120
205
334
1
3
6
12.5
100
35
200
95
120
120
275
L3
L1
1. W
orm gear with safety brake
Shaft Detail (nominal) & Other Dimensions
2. Motor Ex-de (Ex-e not shown)
Model
ØD
H (mm)
B (mm)
L1 (mm)
L2 (mm)
L3 (mm)
4. T
erminal box
GA 25/15 Ex-e T3
30
33.3
8
561
355
159
5. Hand crank
GA 25/15 Ex-de T3
30
33.3
8
611
400
160
GA 25/15 Ex-de T4
30
33.3
8
665
380
160
GA 40/15 Ex-e T3
40
43.3
12
561
355
159
GA 40/15 Ex-de T3
40
43.3
12
611
400
160
GA 40/15 Ex-de T4
40
43.3
12
665
380
160
3. Limit switch
6. Floating foot
GA80/12HXDT4
170
108
4
2
5
1
250
306
16
394
ø55
481
7
135
3
6
16.5
59.3
145
55
113
140
160
290
165
370
844
1. Worm gear with safety brake. 2. Motor with integrated brake. 3. Limit switch. 4. T
erminal box. 5. Hand crank. 6. Floating foot. 7. Intermediate gear.
Ranger RP09/24HXE, RS09/24HXE & RP09/24HXD, RS09/24HXD
50
L4
1
5
2
28.4
45
100
L3
45
M8 x 16
45
55
170
45
4
6.35
L2
Ø25.4
3
57
169
L1
1. Worm gear
L1 (mm)
L2 (mm)
L3 (mm)
L4 (mm)
Ranger 90/91 Ex-e
422
247
73
105
Ranger 90/91 Ex-de
472
275
65
120
2. Motor Ex-de (Ex-e not shown)
3. Limit switch
4. Terminal box (mountable on both sides)
5. Hand crank
Torque mount
Drive mounting and shaft details
RK6 for sectional doors
RK1
49.4
98.8
120
Ø25.4
M8 fixings
49.4
98.8
120
RK3
9
Ø25.4
73
83
11
50
100
30
90
60
50
135
Ø11
130
Safety brakes
TOP
H
Connection
cable for
safety switch
ØD
H (mm)
B (mm)
GB40XD
30
33.3
8
GB80XD
40
43.3
12
GB120XD
50
53.8
14
90
B
D
180
DOWN
13.5
25
110
85
100
140
270
60
Rated II 2G IIC c T3
Accessories for use with Control Panels
CC60851*
Wall Mounting Reversing
Starter without push buttons for
mounting inside the hazardous
area rated Ex d[Ex ia IIC] IIB T5
Gb/Ex tb IIIC T82°C Db.
The starter incorporates
Intrinsic Safe Circuits for Push
Buttons and Interlock switches
enabling the use of Non Atex
push button stations and Non
Atex Interlock switches e.g.
Shootbolt Interlocks.
GE23080*
TS 956 ATEX control panel
for mounting outside the
hazardous area
GE23066*
TS 961 ATEX automatic door
control panel for mounting
inside the hazardous area
Rated Ex II 2G Ex d [ia] IIC T6 /
Ex II 2D IP66 T85°C
GE34692*
Reflective photobeam 8m
range rated Ex II 2G Ex ia IIC
T6 for use with TS 961
Atex Panels
EXAWG03*
3 Button station GRP Enclosure
rated Ex 2G Ex d IIC T6 / II 2D
IP66 T80°C
EXAWG04
3 Button station with keyswitch
GRP enclosure rated Ex II 2GD
Ex de IIC T6 Ex tD A21 T85°C
EXAWF101
3 Position keyswitch Alloy
enclosure rated Ex II 2GD Ex de
IIC T6 Ex tD A21 T85°C
GE414087*
16 Amp Isolator switch rated
Ex II 2G Ex-d IICT6/II 2D IP66
T80°C
GE414675*
Junction box rated Ex II 2G Ex
ia IIC T6 / II 2D IP66 T80°C
GE23065*
TS 961 ATEX automatic door
control panel for mounting
outside the hazardous area
Gelbau safety edge for use
with TS 961 ATEX control panel
GE23066 and GE20365
GE413344*
M16 Gland
GE413332*
M20 Gland
rated Ex II 2G Ex-e II / II 2D IP66
*ILLUSTRATED
GfA ELEKTROMATEN UK Ltd
Unit 1, Titan Business Centre,
Spartan Close, Warwick, UK. CV34 6RR
Tel: (+44) 01926 452 452
Fax: (+44) 01926 336 417
Email: [email protected]
Company Reg. No. 1489927 V.A.T Reg. No. GB 307 3656 62 © 08.14
www.gfa-elektromaten.co.uk