SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 ROBERT BOSCH NORTH AMERICA

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
ROBERT BOSCH NORTH AMERICA
Engineering Technical Center
15000 Haggerty Rd.
Plymouth, MI 48170
Timothy O’Dell
Phone: 734 979 3527
MECHANICAL
Valid To: June 30, 2016
Certificate Number: 3305.01
In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to
this laboratory to perform the following tests on electrical/electronic control modules:
Test
Electrical
Point Functional/Parametric Check
Jump Start
Reverse Polarity
Over Voltage
Discrete Digital Input Threshold Voltage
Crank Pulse Capability and Durability
Power Supply Interruptions
Battery Voltage Dropout
Mechanical
Crush for Housing – Elbow Load1
Crush For Housing – Foot Load1
Connector Tests1
Connector Installation Abuse – Side Force1
Connector Installation Abuse – Foot Load1
Test Method(s)
CETP-00.00-E-412, CS-11982,
ISO 16750-2, GMW3097, GMW3172
GMW3172, GMW3191, USCAR-25
Up to 50 KN of applied force,
Speeds of 1 to 500 mm/sec
Thermal Shock (TS)
Thermal Shock Air-to-Air1
CETP-00.00-E-412, CS-11982, GMW3172,
ISO 16750-4
Temperature Range: (-70 to 200)˚C
Max Product Load: Up to 50 lbs
Temp Transition between Environments: <30s
Thermal Cycle Transitions: Up to 20˚C/min
Visual Inspections
Scanning Electron Microscopy
Optical Microscopy
(A2LA Cert. No. 3305.01) 10/03/2014
CETP-00.00-E-412, CS-11982, GMW3172
Page 1 of 2
Test
Temperature Humidity
Temperature Measurement1
Low Temperature Wakeup1
Frost1
High Temperature Degradation1
Power Temperature Cycle1
Humid Heat Cyclic1
Humid Heat Constant1
Test Method(s)
GMW3172, CS-11982, CETP-00.00-E-412,
ISO 16750-4. IEC 60068-2-38,
IEC 60068-2-78
Temperature Range: (-70 to 170) °C
Max Product Load: Up to 100 pounds
Temperature Transition Rate: 15 °C/min max
Humidity Range: (33 to 98) %RH
Vibration
Vibration With Thermal Cycling1
Post Thermal Fatigue Vibration1
Shipping Vibration1
ASTM D4728, CETP- 00.00-E-412,
CS-11982, GMW3172, IEC 60068-2-64
Random, Sine, Sine-on-Random
Resonance Search and Dwell
Frequency Range: (5 to 2,500) Hz
Force Capabilities: Up to 14,000 lb. Force
Displacement: Up to 3 inch Peak-to-Peak
Temperature Range: (-73 to 190)°C
Temperature Transition Rate: 5°C/minute max
Humidity Range: (33 to 98)% RH
Multiple Channel Control/Monitoring
Mechanical Shock
Mechanical Shock – Pothole1
Mechanical Shock – Collision1
Mechanical Shock – Closure Slam1
CETP-00.00-E-412, CS-11982,
Fiat 9.90110, GMW3172, IEC 60068-2-27
Waveform: Half-Sine, Triangular
Maximum g Level: Up to 800g
Duration: (1 to 30) ms
Corrosion
Salt Fog1
Salt Mist1
ASTM B117
GMW3172, IEC 60068-2-52
Ambient Temp to 70˚C
Ambient to 100% RH
Free Fall
GMW3172
1
Also using the above methods and customer supplied test methods directly related to the capabilities
listed above.
(A2LA Cert. No. 3305.01) 10/03/2014
Page 2 of 2
A2LA has accredited
ROBERT BOSCH NORTH AMERICA
Plymouth, MI
for technical competence in the field of
Mechanical Testing
This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General requirements for
the competence of testing and calibration laboratories. This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009).
Presented this 3rd day of October 2014.
_______________________
President & CEO
For the Accreditation Council
Certificate Number 3305.01
Valid to June 30, 2016
For the tests to which this accreditation applies, please refer to the laboratory’s Mechanical Scope of Accreditation.