Electric League – Oct. 16th 2014 The latest in Circuit Breaker and equipment technologies: Cameron Clark– Application Engineer Eaton Corporation © 2012 Eaton Corporation. All rights reserved. Different Types And Sizes • Molded Case Circuit Breaker (MCCB) “A circuit breaker that is assembled as an integral unit in a supporting and enclosing housing of insulating material.” • Insulated Case Circuit Breaker (ICCB) “A circuit breaker that is assembled as an integral unit in a supporting and enclosing housing of insulating material and with a stored energy mechanism.” • Low Voltage Power Circuit Breaker (LVPCB) “A mechanical switching device, capable of making, carrying, and breaking currents under normal circuit conditions and making and carrying for a specified time and breaking currents under specified abnormal circuit conditions such as those of short circuit. Rated 1000 V ac or below, or 300 V dc and below, but not including molded-case circuit breakers.” Ref: IEEE Std 1015 – 2006 “IEEE Blue Book – Applying Low Voltage Circuit Breakers Used in Industrial and Commercial Power Systems” © 2012 Eaton Corporation. All rights reserved. 2 Molded Case Circuit Breakers Miniature G Frame E Frame F Frame J Frame K Frame L Frame M Frame N Frame R Frame 15 – 100A 15 – 100A 15 – 125A 10 – 225A 70 – 250A 70 – 400A 70 – 600A 300 – 800A 320 – 1200A 800 – 2500A • • • • Continuous Ampere Ratings from 15A to 2500A Frame Interrupting Capabilities of 22KA to 100KA Found In enclosures, panelboards, switchboards, MCCs and Control Panels Industrial AND Residential Applications © 2012 Eaton Corporation. All rights reserved. 3 Insulated Case Circuit Breakers • Typically 800A – 6000A Frame Range • Interrupting Duty 35 – 150kA • Found In Enclosures, Switchboards and Switchgear © 2012 Eaton Corporation. All rights reserved. 4 Power Circuit Breakers • Interrupting Duty from 42kA to 100kA and Current-Limiting Up To 200kA • 800A to 6000A Frame • Found in Enclosures, Switchboards, and Switchgear © 2012 Eaton Corporation. All rights reserved. 5 Thermal Magnetic Time Current Characteristic Curve © 2012 Eaton Corporation. All rights reserved. 6 Electronic Trip Units • 1973 Saw The Introduction of The Seltronic™ Circuit Breaker • The First Electronic Circuit Breaker On The Market © 2012 Eaton Corporation. All rights reserved. 7 Integration With The Breaker Trip Unit Circuit Board Flux Transfer Shunt Trip Current Transformer © 2012 Eaton Corporation. All rights reserved. 8 Time-Current Characteristic Depicts the time required for an overcurrent protective device to open automatically Long Time Pickup 1000 Long Time Delay Time In Seconds 100 Short Time Pickup 10 Short Time Delay (I2t) 1.0 0.1 0.01 0.005 0.5 Instantaneous Pickup 1 10 • Three Regions • Long-time: Opening in minutes • Short-time: Opening in seconds or tenths of seconds. • Instantaneous: Opening with no intentional delay - milliseconds 100 Multiples of Rated Current © 2012 Eaton Corporation. All rights reserved. 9 Arc Detection / Fire Prevention • Technology Has Progressed To Enable Enhancement Of The Residential MCCB • Residential And Commercial Applications © 2012 Eaton Corporation. All rights reserved. 10 © 2012 Eaton Corporation. All rights reserved. 11 Product Overview Power Components Division Molded Case Circuit Breaker Product Line MCCB Series G Specialty Series C Engine Gen Electronics DP Mining 310+ HMCP Navy / DC / Solar Optim PM3 Accessories © 2012 Eaton Corporation. All rights reserved. 12 © 2012 Eaton Corporation. All rights reserved. 13 Arc Reduction Maintenance System ARMS • ALWAYS WORK DE-ENERGIZED when possible • Manually or Automatically enables analog instantaneous pickup • Protects all downstream equipment / personnel • Limits energy available during maintenance © 2012 Eaton Corporation. All rights reserved. 14 Arc Flash Reduction Switch • Clearing times are much faster than ZSI • Clearing times are faster than standard INST Ref: Incident energy calculated using IEEE STD 1584TM-2002 method for a 480 Vac system, working distance of 24 inches, © 2012 Eaton Corporation. All rights reserved. 15 Grounding type = solid grounded and Equipment type = Switchgear. 240.87 – Arc Energy Reduction • Where the highest continues current trip setting for which the actual overcurrent device installed in a circuit breaker is rated or can be adjusted is 1200A or higher, 240.87(A) and (B) shall apply. • (A) Documentation shall be provided … as to the location of the circuit breakers(s) • (B) Method to Reduce Clearing Time. One of the following… • Zone-selective interlocking • Differential relaying • Energy-reducing maintenance switching with local status indicator (=A.R.M.S) cost effective method of compliance • Energy Reducing active arc flash mitigation system • An approved equivalent means. © 2012 Eaton Corporation. All rights reserved. 16 PM3 Overview Features and Benefits of PM3: Communications electrical system data and breaker status via Modbus and INCOM Compliant to ANSI C12.1 standard Measures current & voltage to 0.5% of reading Calculates power & energy to 1.0% of reading Works with T/M or ETU breaker assemblies Suitable for reverse feed applications Reduced installation time versus traditional metering solutions Improved cost position Field installable or factory configurable Metering and Communications from 15A through 600A applications Additional features when combined with 310+ ETU © 2012 Eaton Corporation. All rights reserved. 17 PM3 Technical Information Specifications: Connection to breaker: load-side only, bolted connection Operating voltage: 240V/480V & 240V/480V/600V Interruption capacity: dependent on molded case circuit breaker Measurement Accuracy: 0.5% Current & Voltage 1.0% calculated Power and Energy Certifications: UL, CSA, Tested to ANSI C12.1 Communications: Modbus RTU with capability to daisy chain up to 247 PM3’s (limitations depending on system loads and cable length*) INCOM with capability to daisy chain up to 64 PM3’s INCOM = compatible w/INCOM networks Profibus DP = INCOM + PMINT Ethernet Toolkit = Modbus / INCOM + PXG * Refer to Technical Document TD17513 (Eaton Electrical Field Devices Communication Wiring) © 2012 Eaton Corporation. All rights reserved. 18 MCCB PM3 – Power Monitoring and Metering Module Cat #’s: PM3L3630C02V48M & PM3L3630C02V60M Overview: Measures current, voltage, power, and energy with an accuracy to 2% of reading Monitors electrical system status and communicates via INCOM protocol (today) Connects to load side of LG or KD, independent of trip unit type (ETU or T/M) 480V version includes integral power supply; 600V requires 24Vdc aux power (PM3 available in PGX in 2011Q4) © 2012 Eaton Corporation. All rights reserved. 19 © 2012 Eaton Corporation. All rights reserved. 20 Pow-R-Line MPM Multi-point Metering Panelboard and Switchboard Technical Information: Revenue Grade, Modular design for scalability, ANSI C12.20 accuracy meter (required for multi-unit billing) Description: Integration of new Eaton revenue grade PX-MP metering components into PRL4 Panelboard and PRLC Switchboard assemblies. Value : Integrated design with no wasted space for external metering device. Reduced onsite labor for wiring and installing the meter and CTs. © 2012 Eaton Corporation. All rights reserved. 21 PX Multi-Point Meter • Up to 60 current inputs (Wh meters) • 60 single phase, or • 30 dual phase, or • 20 three phase • …or any combo of the above using 60 inputs • 120/208(240) or 277/480 or 346/600 VAC • One voltage for entire meter – based on application • Measurements (Instrumentation, Power & Energy) • Current, Voltage, Power, Demand – per phase, Total, Min/Max • Total Energy – real, reactive, apparent, forward, reverse • 256MB memory = 2 yrs of 15-min OR 8 yrs of 60-min interval demand © 2012 Eaton Corporation. All rights reserved. 22 Factory Assembled Solution • Factory-wired system • Available in Distribution Panels • And Switchboards • Centralized display • Simple Commissioning (EESS) © 2012 Eaton Corporation. All rights reserved. 23 Enclosed Solution Fused Disconnect 6” Color Fuses PXMP Power Supply Touchscreen Meter Modules Sold Separately NEMA 12 Enclosure 30”HX24”WX12”D © 2012 Eaton Corporation. All rights reserved. PXMP Meter Base 24 Drawout Molded Case Circuit Breaker Panelboards & Switchboards © 2012 Eaton Corporation. All rights reserved. Introducing Eaton’s Drawout Molded-Case Breakers in Panelboards & Switchboards • First drawout molded-case circuit breaker design for panelboards and switchboards • Unique drawout MCCB mechanism allows • Users to mechanically remove MCCBs • No deadfronts or covers to remove • Smaller footprint than switchgear • High density design allows for up to 14 drawout MCCBs in a single switchboard distribution section © 2012 Eaton Corporation. All rights reserved. 26 Drawout MCCB Base Cassette Drawout handle fits here. Turn clockwise to rack breaker in Turn counter clockwise to rack breaker out Indicator changes color when the drawout breaker cassette is connected and when it is disconnected. Indicator turns RED when connected 250A Max. JG Single Base Cassette Indicator turns GREEN when disconnected © 2012 Eaton Corporation. All rights reserved. 27 Drawout MCCB Base Cassette • Drawout MCCBs available in single and dual mount configurations through 600 amp Single 250A Max JG Adapter Single 600A Max LG Adapter Dual 250A Max JG Adapter Dual 600A Max LG Adapter ① ① Available only in switchboard construction © 2012 Eaton Corporation. All rights reserved. 28 Series NRX Breaker • UL 1558 Switchgear with UL 1066 • Breakers available in 24” wide structure to include 2.5” wireway (as shown) • Fit two 800A circuit breakers in the space of one traditional cell. • 800A maximum rating • 65 kAIC withstand, 42 kAIC short time rating © 2012 Eaton Corporation. All rights reserved. 29 LVA – Front Access: 22” • 200KA system-short-circuit ratings achieved. • Eliminates use of Cross Bus as Load Side Runbacks on 3,200 amps and above • Staggered Cable terminations for ease of installation. • Adds Full Size Magnum DS Breakers to Front Access Product Portfolio. • ARM’s Compatible. © 2012 Eaton Corporation. All rights reserved. 30 Integral Motorized Remote Racking for MVBreakers – MR2 (www.eaton.com/mr2) Product - Integral motorized remote racking for VCP-W Breakers rated 5 through 38 kV Value : Personnel safety • Allows operator to remain outside the arc-flash zone while racking circuit breaker to/from its connected position • LEDs on pendant indicate breaker positions within the cell • Breaker can be racked in/out via remote control Key Specifications: • For new products as well as retro-fit kits for existing products • 5, 15, 27 & 38 kV VCP-W breakers • Optional HMI screen as another means to control the breaker • Pendant allows for remote operation • Access to I/O ports for remote interface Available Now! © 2012 Eaton Corporation. All rights reserved. 31 Integral Motorized Remote Racking for Auxiliaries – MR2 New in 2014 Product : Integral motorized remote racking for 5 & 15 kV Auxiliary drawers For ½ High Aux Drawer (Arc structures) – Taking Beta orders For ¼ High Aux Drawer (Non-Arc structures) – Q3 2014 Value: Personnel safety • Allows operator to remain outside the arc-flash zone while racking auxiliary drawer to/from its connected position • LEDs on pendant indicate drawer position within the cell • Auxiliary drawer can be racked in/out via remote controls Key Specifications: • For new products as well as retro-fit kits for existing products • Available for 5 & 15 kV auxiliary drawers • Pendant allows for remote operation • Access to I/O ports for remote interface Available Now! © 2012 Eaton Corporation. All rights reserved. 32 FlashGardTM MCC The Ultimate Solution © 2012 Eaton Corporation. All rights reserved. 33 The FlashGardTM Bucket Racking Tool Receiver Unit Latch Internal Shutter Position Open Closed Bucket Position Connected Test Withdrawn Handle Mechanism Device Island • Start, Stop, Auto, Man Breaker Starter © 2012 Eaton Corporation. All rights reserved. 34 © 2012 Eaton Corporation. All rights reserved. 35
© Copyright 2024