CTO 102 – ROV SURVEY

Tandstangsmotor
rack and pinion drive
ZA 35 / ZA 85(-HS) / ZA 105(-HS) / ZA 155
24VDC
B 08 11 22802 026
Zertifikat-Nummer
certificate-number
Produktbeskrivelse
For alle vinduestyper
for all types of windows
Mikroprocessorstyret motorelektronik
microprocessor-controlled motor electronic
Individuel programmerbar via PLP
individual programmable via PLP
Anvendelig for ABV og komfortventilation
applicable for smoke and natural ventilation
Høj tryk- og trækkraft, op til 1500 N
high pressure and tensile force, up to 1500 N
Stor åbningslængde, op til 1000 mm
stroke lengths, up to 1000 mm
ABV-system
Smoke- and Heat Vent Systems
Naturlig ventilations-system
Natural Ventilation Systems
Motor-system
ABDL-system
Drive Systems
Fire-door Control Systems
3.3.0.0
Product Information
ZA 35 / ZA 85 / ZA 105 / ZA 155
Kendetegn
Features
-
-
-
-
Anvendelseseksempel
15
Standard udførsel /
Standard version
useable for smoke ventilation, D+H Euro-SHEV according to
DIN EN 12101-2 as well as daily natural ventilation
for façade windows, roof flaps and dome lights
available as high-speed version (HS) for a fast
window opening in case of fire
adjusting of stroke with PLP1 directly at the drive
individually programmable via Powerline
(PLP1 and PDA service tool)
low power consumption due to an high efficiency
fire resistance (30 minutes/300°C) and
10.000 double strokes with rated push strength, tested
extra silent motor running in ventilation mode
cable entry and drive unit interchangeable
possibility of paint in all RAL-colours
individual stroke lengths and change of structural dimensions
possible
mounting-sets coordinated with profile systems available
Example for Application
Bestil venligst konsolsættene separat /
please order bracket sets separately
-3
Ø
6
5
max. Kraft / max. load / N
46
12
9
10
4
0
16
Maximal tryklast på tandstangen /
maximum pressure load of toothed rack
1600
13
30
-5
5
Ny
tte
åb
n.
/n
om
ina
9
ls
tro
ke
+1
1200
1000
62
30
9
13
vedvarende / durable
800
600
400
200
0
30
21
korttid / temporary
1400
6
7
500 600 700 800 900 1000 1100 1200
Åbn. / stroke / mm
Tekniske data
Udførelse uden Tubus (Option "-OT") /
Version without tube (option "-OT")
Technical Data
Motortype / type
ZA 35
ZA 85 (HS)
Strøm / rated current
0,5 A
1,0 A (2,0 A) 1,2 A (2,2 A) 1,4 A
Trykkraft / rated push strength
300 N
800 N
1000 N
1500 N
Trækkraft / pull strength
300 N
800 N
1000 N
1000 N
Lukkekraft / closing strength
300 N
24 VDC ±15%
Spænding / rated voltage
Type
Type
Art.-Nr.
Ord.-No.
ZA 35/350
ZA 35/500
ZA 35/600
ZA 35/800*
ZA 85/350
ZA 85/500
ZA 85/600
ZA 85/800*
ZA 85/1000*
ZA 105/500
ZA 105/600
ZA 105/800*
ZA 105/1000*
ZA 155/500
ZA 85/600-HS
ZA 85/800-HS*
ZA 85/1000-HS*
ZA 105/600-HS*
ZA 105/800-HS*
27.005.05
27.005.10
27.005.15
27.005.20
27.005.30
27.005.35
27.005.40
27.005.45
27.005.50
27.005.60
27.005.65
27.005.70
27.005.75
27.005.90
27.006.05
27.006.10
27.006.15
27.006.30
27.006.35
Realåbn. Kraft Vægt
Tandstang
real stroke Force Weight Gear rack
350mm
500mm
600mm
800mm
350mm
500mm
600mm
800mm
1000mm
500mm
600mm
800mm
1000mm
485mm
600mm
800mm
1000mm
600mm
800mm
300N
300N
300N
300N
800N
800N
800N
800N
800N
1000N
1000N
1000N
1000N
1500N
800N
800N
800N
1000N
1000N
1,72kg
1,95kg
2,10kg
2,40kg
1,72kg
1,95kg
2,10kg
2,40kg
2,70kg
1,95kg
2,10kg
2,40kg
2,70kg
1,95kg
2,10kg
2,40kg
2,70kg
2,10kg
2,40kg
Messing / brass
Messing / brass
Messing / brass
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
V2A / stainless steel
ZA 105 (HS) ZA 155
Forriglingskraft / locking pressure
Løbetid-ÅBNE / opening time
Løbetid-ÅBNE / opening time (HS)
Løbetid-LUKKE / closing time
800 N
1100 N
~ 7,1 mm / s
Lastafhængig
~ 8 mm / s (~ 17 mm / s) load-dependent
~ 7,1 mm / s
Beskyt.grad / protective system
IP 65
Temp.-område / range of temp.
-5°C ... +75°C
Tilslutning / connection
Hus / housing
2,5 m silikone
Aluminium / Polycarbonate
* Uden boring forneden. Kun for konsolmontage foroven.
Without boring at bottom. Only for topside mounting.
Forbehold for tekniske ændringer.
Rights to technical modifications reserved.
© 2010 D+H Mechatronic, Ammersbek/Lumex A/S
Lumex A/S · Havnepladsen 12, bygn. 21 · DK-9900 Frederikshavn · Danmark
Tel: +45 98 43 02 44 · Fax: +45 98 43 82 44 · [email protected] · www.lumex.dk
99.730.07 1.8/06/10
-
Anvendelig for åbning for røgventilation, D+H Euro-RWA
i.h.t DS/EN 12101-2 såvel som daglig ventilation
For facadevinduer, taglemme og ovenlyskupler
Kan fåes som Highspeed-Version (HS) for en speciel hurtig
åbning af vinduerne i tilfælde af brand (ABV)
Indstilling af åbningslængde med PLP 1
Individuel programmerbar via Powerline
(PLP 1 og PDA Servicetool)
Lavt strømforbrug via høj virkningsgrad
Temperaturstandsikkerhed (30 min./300°C) og
10.000 dobbeltoperationer afprøvet med nyttelast
Speciel lydreduceret funktion ved komfortventilation
Kabelindgang og motorenhed kan ombyttes
Lakering i alle RAL-farver mulig
Individuelle åbningslængder og motordimensioner er mulig
Profilsystem afstemte montage-sæt kan fåes