SUBSTATION AUTOMATION PRODUCT SOLUTIONS DAP IO DNP3 Substation I/O module The next generation input/output module for substation automation and SCADA RTU applications Substation automation I/O module for your Smart Grid applications Leveraging the latest technology in microprocessors, communications and applications, the Alstom DAP IO is the next-generation input/output (I/O) module for substation automation and SCADA RTU applications. The DAP IO module can be deployed with Alstom's DAPserver as a standalone RTU or integrated with IEDs to form a substation automation system. It can also be used to replace legacy RTU I/O modules with minimal field wiring changes. DAP IO is the most practical and cost effective solution for substation RTU and automation upgrades and retrofits. NEXT GENERATION I/O MODULE The next generation of input/output modules for electrical utility automation Substation automation Primary equipment monitoring CAPTION_lorem ipsum Distribution automation APPLICATIONS CUSTOMER BENEFITS Next-generation of control I/O modules Legacy I/O replacement with terminal block alignment and minimal field wiring required New substation RTU I/O deployment Legacy RTU I/O expansion and replacement I/O modules for integrated substation control systems I/O modules for primary equipment monitoring I/O modules for distribution automation, e.g.: • On-Load Tap Changer (OLTC) interface • Capacitor bank interface • Voltage regulator interface Upgrade legacy equipment with added features and increased performance © ALSTOM 2014. All rights reserved. Four hardware configuration models available for optimal adaptation to your project Grid-SAS-L3-DAP IO module_DNP3-3133-2014_09-EN. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Alstom contributes to the protection of the environment. This leaflet is printed on environmentally friendly paper. FEATURES FOUR I/O MODULE TYPES LED indicators Compression terminal blocks DAP-MIO (mixed I/O module) - Digital inputs x16 - Analog inputs x16 - Control outputs x8 Option: plug-in terminal blocks 3U rack/panel compact profile DAP-DI - Digital inputs x64 DAP-AI - Analog inputs x32 Local/Remote switch Digital Inputs Analog Inputs Positive/negative polarity 20-60 Vdc (5 mA), 90-290 Vdc (2 mA) 1 ms time-stamp event ±1-20 mA current inputs (0.1%) ±5-10 Vdc voltage inputs (0.05%) DAP-CO - Control outputs x32 Control Outputs Trip/close control outputs, Form-C control outputs, with: - V/I supervision on last two, or - dual-polarity control outputs SCADA / EMS / DMS SCADA / IP NETWORK DAPserver automation system Standalone RTU Substation HMI DAPmini upgraded legacy RTU DAP-100 DAP-IO modules DAP-IO modules Multi-vendor IEDs SUBSTATION AUTOMATION PRODUCT SOLUTIONS DAP IO COMMUNICATION INTERFACE Redundant-switched Ethernet ports Redundant 10/100 Mbps Ethernet switched ports (RJ-45) Switched ports can be daisy-chained to other I/O modules 10/100 Mbps LAN #1 LAN #1 Switched Port DNP3 protocol support 10/100 Mbps LAN #2 LAN #2 Switched Port POWERFUL TOOLS DAPserver Studio - configuration, maintenance and diagnostic tool Local access - USB port Remote access - Ethernet LAN USB 2.0 port DAISY-CHAINING I/O MODULES DAPserver LAN #1 LAN #2 DAP IO DAP IO DAP IO DAP IO SUBSTATION AUTOMATION PRODUCT SOLUTIONS DAP IO DAP IO ORDER GUIDE 1st digit "u" Termination 2nd digit "v" Control Output 3rd & 4th digit "ww" Analog Input 5th digit "x" 6th digit "y" 7th digit "z" Digital Input Power Supply Ethernet Part Number DAP-MIO DAP-DI DAP-AI DAP-CO IO-uvwxyz DI-uvwxyz AI-uvwxyz CO-uvwxyz DESIGNED FOR SUBSTATION IEEE 1613 communication networking devices IEEE C37.90 relays for electrical power apparatus IEEE 1686 cyber security IEEE 1588 / IEC 61588 Precision Time Protocol (PTP) IEEE 1815 DNP3 protocol IEC 60870 telecontrol equipment and systems IEC TS 61000-6-5 immunity for power station & substation IEC 60255-5 relay insulation IEC 61010-1 safety UL/CSA safety CE electromagnetic compatibility & low voltage safety For more information please contact Alstom Grid: RoHS/WEEE/REACH -40°C to +85°C operating range Alstom Grid - SAS Calgary #8, 2121 - 29th Street NE Calgary, Alberta, Canada T1Y 7H8 Phone (North America): +1 403 569 1680 © ALSTOM 2014. All rights reserved. Alstom Grid Worldwide Contact Centre www.alstom.com/grid/contactcentre/ Phone: +44 (0) 1785 250 070 Picture caption Grid-SAS-L3-DAP IO module_DNP3-3133-2014_09-EN. Information contained in this document is indicative only. No representation or warranty is given or should be relied on that it is complete or correct or will apply to any particular project. This will depend on the technical and commercial circumstances. It is provided without liability and is subject to change without notice. Reproduction, use or disclosure to third parties, without express written authority, is strictly prohibited. Alstom contributes to the protection of the environment. This leaflet is printed on environmentally friendly paper. Visit us online: www.alstom.com
© Copyright 2024