J.02 AGYG LVCB (-25°C) Accessories

J.02
Air conditioning
and heatpumps
AGYG LVCB
(-25°C)
Fujitsu
Mono Split
Heatpump inverter
Indoor unit, floor type
Accessories
Compact floor models Fujitsu type
AGYG LVCB (-25°C)
This compact floor model with its simple and flat design can be fitted harmoniously
into any interior. This inverter mono split air-air heating pump for outdoor units of
the AOYG type has an energy label A unit and is equipped with an IR remote control.
AOYG LVCN (-25°C)
Inverter outdoor Units Fujitsu
UTY-RVNYM
Accessories - Wired controller
WBAT2
Wall supports
MPS
Mounting blocks
WBI
Wall supports
MPR
Anti-vibration Mounting blocks
with rail
P-COIL
Insulated double copper tubes
Brand
Fujitsu Airconditioning
Product
Indoor unit mono split type, compact floor model
Application
Cooling or heating of small offices, living rooms, salons, bedrooms, porches
Installated beneath standard window or in standard concave portion or on wall
For areas between 20 and 45 m²
Function
Heatpump Air-Air, Inverter type
Refrigerant
R410A
Features
IR controller is standard included
Wired remote controller possible as accessory
Mounting position always vertical
Four fan speeds (High/Medium/Low/QUIET)
Always supplied with long-life ion deodorization and apple-catechin filters
Trendy & compact design
Removable and washable front panel
Choice of 6-direction drain and piping connection
Air outlet selection (Upper and lower fan or only upper fan)
Upper fan prevents cold air from falling in summer and cold draft from window
J.02 AGYG LVCB (-25°C) 1/3 - 2014/10/23 - BE-EN
www.airtradecentre.com
J.02
Air conditioning
and heatpumps
in winter
Wide space inside for piping work
Moisture removal
Up/Down swing flaps
Automatic flaps
Auto shut flaps
Automatic air flow adjustment
Auto restart
Sleep and/or daily timer
ON-/OFF-timer
EIB input - & output signal
Applicable outdoor units
Type AOYG 09 LVCN
Type AOYG 12 LVCN
Type AOYG 14 LVCN
Accessories
Wired Remote controller. Type UTY-RVNYM
Wired remote controller. Type UTY-RNNYM
Simplified wired remote controller. Type UTY-RSNYM
External connection kit. Type UTY-XWZX
Apple-catechin filter. Type UTR-FC03-2
Long-life ion deodorization filter. Type UTR-FC03-3
Specifications
Technische specificaties "WARMTEPOMP"
Koelvermogen (min. - nom. - max.)*
Verwarmingsvermogen (min. - nom. - max.)*
Koelmiddel
Ontvochtiging
Opgenomen stroom in koeling (nom. - max.)*
Opgenomen stroom in verwarming (nom. - max.)*
Opgenomen vermogen in koeling (nom. - max.)*
Opgenomen vermogen in verwarming (nom. - max.)*
Luchtdebiet (maximum) (K/V)
Luchtdebiet (medium) (K/V)
Luchtdebiet (minimum) (K/V)
Luchtdebiet (Quiet) (K/V)
E.E.R. (koeling)
C.O.P. (verwarming)
Energieklasse
Maximaal geluidsdruk niveau @ 1 m (K/V)
Gemiddeld geluidsdruk niveau @ 1 m (K/V)
Minimaal geluidsdruk niveau @ 1 m (K/V)
Quiet geluidsdruk niveau @ 1 m (K/V)
Afmetingen (H x B x D)
Gewicht binnengroep
Afstandsbediening
Koelleidingen
Maximum lengte/hoogte koelleiding
Afvoer condensaat
Stroomtoevoer
Kabelsectie tss binnen- en buitengroep
* Specificaties en design kan wijzigen zonder bericht voor verdere verbeteringen
* Koeling/Verwarming capaciteiten zijn gerealiseerd bij de volgende condities.
(Koeling) Binnen temp.:27°C D.B./19°C N.B. - Buiten temp.:35°C D.B./24°C N.B.
(Verwarming) Binnen temp.:20°C D.B. - Buiten temp.:7°C D.B./6°C N.B.
J.02 AGYG LVCB (-25°C) 2/3 - 2014/10/23 - BE-EN
kW
kW
l/h
A
A
kW
kW
m³/h
m³/h
m³/h
m³/h
kW/kW
kW/kW
dB(A)
dB(A)
dB(A)
dB(A)
mm
kg
inch
m/m
mm
mm²
AGYG 09 LVCB
0,9 - 2,6 - 3,5
0,9 - 3,5 - 5,5
R410A
1,3
2,7 - /
3,9 - /
0,25 - 0,53
0,25 - 0,79
570 / 600
460 / 480
360 / 370
270 / 270
4,91
4,43
A/A
40/40
35/35
29/29
22/22
600x740x200
14
IR
1/4 - 3/8
20/15
13,6
AOYG
4G 1,5
AGYG 12 LVCB
0,9 - 3,5 - 4,0
0,9 - 4,5 - 6,6
R410A
1,8
4,4 - /
5,6 - /
0,25 - 0,91
0,25 - 1,19
570 / 600
460 / 480
360 / 370
270 / 270
3,72
3,78
A/A
40/40
35/35
29/29
22/22
600x740x200
14
IR
1/4 - 3/8
20/15
13,6
AOYG
4G 1,5
AGYG 14 LVCB
0,9 - 4,2 - 5,0
0,9 - 5,2 - 8,0
R410A
2,1
5,2 - /
6,4 - /
0,25 - 1,14
0,25 - 1,44
650 / 650
520 / 520
380 / 380
270 / 270
3,68
3,61
A/A
44/43
38/37
31/29
22/22
600x740x200
14
IR
1/4 - 1/2
20/15
13,6
AOYG
4G 1,5
www.airtradecentre.com
J.02
Air conditioning
and heatpumps
Accessories
AOYG
LVCN (-25°C) Inverter outdoor
Units Fujitsu
MPS
P-COIL
Mounting blocks
UTY-RVNYM Accessories - Wired
controller
WBI
Wall supports
WBAT2
MPR
Wall supports
Anti-vibration Mounting
blocks with rail
Insulated double copper tubes
J.02 AGYG LVCB (-25°C) 3/3 - 2014/10/23 - BE-EN
www.airtradecentre.com
J.02
Air conditioning
and heatpumps
AOYG LVCN
(-25°C)
Fujitsu
Mono Split
Heatpump inverter
Outdoor unit
Accessories
MPRH
Anti-vibration high Mounting
blocks with rail
WBI
Wall supports
P-COIL
Insulated double copper tubes
Inverter outdoor Units Fujitsu type
AOYG LVCN (-25°C)
Mono split
Brand
Fujitsu Airconditioning
Product
Outdoor unit for compact floor model
Function
Air-Air Heatpump, Inverter
Refrigerant
R410A
Features
Robust and compact
Colour, RAL 7044
Protected valves
3-Bladed rotary fan
DC twin rotary compressor
V-PAM inverter control
DC condensor fan motor
Input power : 230V/1/50Hz
Permissible range of outdoor temperature in heating: -15~24°C
Permissible range of outdoor temperature in cooling: -10~43°C
Applicable indoor units
Type AGYVG 09/12/04 LVCB
J.02 AOYG LVCN (-25°C) 1/2 - 2014/10/23 - BE-EN
www.airtradecentre.com
J.02
Air conditioning
and heatpumps
Accessories
Inox wall support.
Type WBI 110
Metal wall support.
Type WBAT2 90
Drain pan for wall support.
Type CTS
Mounting blocks (rubber)
Type MPR 600
PVC mounting blocks.
Type MPS 450
Massive anti-vibration mounting blocks.
Type MPK 500
Insulated copper pipes on roll.
Type Paircoil 2320-ER (AOYG 09-12) / Paircoil 2420-ER (AOYG 14)
Tape (White).
Type WT50
Specifications
Technical specifications "HEATING PUMP"
Cooling capacity (min. - nom. - max.)*
Heating capacity (min. - nom. - max.)*
Refrigerant
Maximum air flow (C/H)
Power supply
Absorbed current in cooling
Absorbed current in heating
Absorbed power in cooling (min.-nom.-max.)
Absorbed power in heating (min.-nom.-max.)
E.E.R. (cooling)
Starting current
C.O.P. (heating)
Energy consumption / 500hrs
Energy classification
Compressor type
Sound pressure level @ 1 m (High) (C/H)
Dimensions outdoor unit (H x W x D)
Weight outdoor unit
Cooling pipes
Quantity of prefilled refrigerant
Quantity of additional refrigerant
Number of prefilled meters
Maximum length/height cooling pipe
Minimum length cooling pipe
Operation temperature in cooling
Operation temperature in heating
Cable section power supply
Automatic fuse (slow)
* Specifications and design are subject to changes for further improvement without notice.
* Cooling/Heating capacities are realised under the following conditions.
(Cooling) Indoor temp.:27°C D.B./19°C N.B. - Outdoor temp.:35°C D.B./24°C N.B.
(Heating) Indoor temp.:20°C D.B. - Outdoor temp.:7°C D.B./6°C N.B.
kW
kW
m³/h
V
A
A
kW
kW
kW/kW
A
kW/kW
kWh
dB
mm
kg
inch
g
g/m
m
m/m
m
°C
°C
mm²
A
AOYV 09 LAC
0,9 - 2,6 - 3,5
0,9 - 3,5 - 5,5
R410a
1680/1490
230/1
2,6
3,8
0,25 - 0,53 - 1,35
0,25 - 0,79 - 2,10
4,91
3,8
4,43
290
A/A
Rotary
47/48
540x790x290
36
1/4 - 3/8
1050
20
15
20/15
3
-10~43
-15~24
3G 2,5
20
AOYV 12 LAC
0,9 - 3,5 - 4,0
0,9 - 4,5 - 6,6
R410a
1680/1680
230/1
4,4
5,5
0,25 - 0,94 - 1,40
0,25 - 1,19 - 2,15
3,72
5,5
3,78
510
A/A
Rotary
48/49
540x790x290
36
1/4 - 3/8
1050
20
15
20/15
3
-10~43
-15~24
3G 2,5
20
AOYV 14 LAC
0,9 - 4,2 - 5,0
0,9 - 5,2 - 8,0
R410a
1910/1750
230/1
5,2
6,4
0,25 - 1,14 - 1,90
0,25 - 1,44 - 2,95
3,68
6,4
3,61
615
A/A
Rotary
50/50
578x790x300
40
1/4 - 1/2
1150
20
15
20/15
3
-10~43
-15~24
3G 2,5
20
Accessories
MPRH
Anti-vibration high Mounting blocks with rail
J.02 AOYG LVCN (-25°C) 2/2 - 2014/10/23 - BE-EN
WBI Wall supports
P-COIL Insulated double copper tubes
www.airtradecentre.com