Micro Inverter [ INDOOR UNIT ] FDU DUCT CONNECTED -High Static pressureR410A Point 1 Quiet operation:45dB(A) Thanks to use of DC fan motor, fan steps increase from two to four and quiet operation is achieved. (Sound pressure level 45dB(A) in the Lo mode). NEW 2 Improvement of the serviceability Point Fan unit (impeller and motor) can be pulled out from the right side of the unit. Maintenance can be available from the right side or the bottom side. (Common for FDU100VF1~140VF & FDUM100VF1~140VF) FDU 200/250 Pipe Fan unit 3 High efficiency Point Remote control (Option) Wired Energy efficiency is improved by use of DC fan motor & high efficient heat exchanger. Wireless 8HP (in case of 50Hz) 4 3 RC-EX1A RC-E5 RCH-E3 RCN-KIT3-E 3.03 Models FDU200,250VG 2.52 3.01 10HP 4 2 1 1 Current New Current EER New 3.68 3.72 Current New 3 2 COP Dimensions (Unit:mm) 3.09 COP (in case of 50Hz) 3.29 Current EER 3.75 New SPECIFICATIONS Set model name Indoor unit Outdoor unit Power source Nominal cooling capacity (Min~Max) Nominal heating capacity (Min~Max) Power consumption Cooling/Heating EER/COP Cooling/Heating Inrush current 220/230/240 V Max. running current Sound power Indoor Cooling/Heating level*1 Outdoor Cooling/Heating Cooling (Hi/Me/Lo) Sound Indoor pressure Heating (Hi/Me/Lo) level*1 Outdoor Cooling/Heating Cooling (Hi/Me/Lo) Indoor Heating (Hi/Me/Lo) Air flow Outdoor Cooling/Heating External static pressure*2 Indoor Exterior HeightxWidthxDepth dimensions Outdoor Indoor Net weight Outdoor Ref.piping size Liquid/Gas Refrigerant line (one way) length Vertical height differences Outdoor is higher/lower Cooling Outdoor operating temperature range Heating Air filter Remote control (option) kW kW kW A dB(A) m3/min Pa mm kg ømm m m °C FDU200VSAVG FDU250VSAVG FDU200VG FDU250VG FDC200VSA FDC250VSA 3 Phase 380-415V 50Hz, 3 Phase 380V 60Hz 19.0 ( 5.2 ~ 22.4 ) 24.0 ( 6.9 ~ 28.0) 22.4 ( 3.3 ~ 25.0 ) 27.0 ( 5.5 ~ 31.5 ) 6.15 / 6.03 7.98/7.20 3.09 / 3.71 3.01/3.75 5 5 25 27 75 / 75 75 / 75 72 / 74 73 / 75 50 / 47 / 45 50 / 47 / 45 57 / 59 59 / 62 72 / 64 / 56 72 / 64 / 56 135 143 / 151 Standard:72 Max:200 379 x 1,600 x 893 1,300 x 970 x 370 1,505 x 970 x 370 89 115 143 9.52(3/8") / 22.22(7/8") 12.7(1/2") / 25.4(1") Max.70 Max.30 / Max.15 -15~50*3 -15~20 Procure locally wired:RC-EX1A, RC-E5, RCH-E3 wireless:RCN-KIT3-E The data are measured under the following conditions(ISO-T1). Cooling:Indoor temp. of 27˚CDB, 19˚CWB, and outdoor temp. of 35˚CDB. Heating:Indoor temp. of 20˚CDB, and outdoor temp. of 7˚CDB, 6˚CWB. External static pressure is 72Pa. Indicates the value in an anechoic chamber. During operation these values are somewhat higher due to ambient conditions. *21 :: External static pressure is changeable to be set by the remote control. MAX external static pressure is ''High static pressure'' setting. The values of sound pressure level * become 5dB(A) higher at external static pressure of 200Pa. a cooling operation is conducted when the outdoor air temperature is –5˚C or lower, the outdoor unit should be installed at a place where it is not influenced by natural *3 : Ifwind. If wind blows, the low pressure will drop and compressor frequency will increase, this will cause the capacity to drop and may cause the unit to break down. Powerful-Hi can be selected. Sound level: 200/250VG: 52dB Air flow: 200/250VG: 80m3/min
© Copyright 2024