CONV2-E version 3 Protocol converter from Pelco-D to Bosch Bi-phase MANUAL INSTRUCTION The converter is a microprocessor device, designed to control PTZ cameras Enviro Dome by uses keyboards (or DVRs), working in Pelco-D protocol. This allows for integration of Bosch company cameras with any other camera system or digital recorders. The converter receives commands in Pelco-D protocol by uses RS-485 interface and after translation the data by appropriate software, the commands are sending by Bi-Phase output. 1. Structure of connections The converter is connected between keyboard and PTZ cameras and it requires 9~24V D or AC supply. 9~24V AC/DC Keyboard Klawiatura (Pelco-D) Bosch camera G3 / G4 Kamera Bosch CONV2-E (Pelco-D) G3 / G4 RS485 Bosch Biphase Connection diagrams of CONV-2E converter 2. Description of connection terminals 1 10 LED1 – signal transmission of Bi-Phase LED2 – signal transmission of Pelco-D 10 9~24V Zasilanie Zasilanie Term1 RS485 - A + Klawiatura GND RS485 - B Term2 Biphase + GND Biphase - 1 Ewimar Sp. z o.o. www.ewimar.pl Power supply: It used to connection 9~24V DC / AC supply RS-485 A/B: RS-485 interface, designed to connection keyboard Term1: 120Ω terminating resistor for RS-485 interface Biphase +/ -: Bi-Phase interface, designed to connection cameras Term2: 120Ω terminating resistor for Bi-Phase interface GND: Clamps of power ground (cable shield) RS-485 interace, should be connected always in accordance with other devices A to A and B to B. Biphase interface, should be connected accordingly do clamps C+ i Cin Bosch. CONV3-A/B rev 1.0 A B R R C+ CConnection Połączenia ofwewnątrz inside For longer cables of bus, both RS-485 interface and Biphase, should be included to terminating resistor. This will prevent wave reflections in cables, which are cause of transmission errors. Terminating resistors should be connected only in devices, which are of ends of the bus. Larger number of resistors will cause an excessive burden of transmission. Zwory Jumpers Switching resistors in converter consists in the combination wire clamp TERM1 with A+ and TERM2 with Biphase+, respectively for RS-485 and Bi-phase interfaces. 3. Description of switches OFF (up) ON (down) Description of switches: Transmission speed 2400baud 4800baud 9600baud 19200baud RS-485 DIP 1 OFF ON OFF ON DIP 2 OFF OFF ON ON Transmission speed is is defined only for RS-485 interface, transmission speed for Bi-phase isn’t changeable. Input protocol Pelco-D (work as CONV-2E) Pelco-P (work as CONV-2G) DIP 3 OFF ON Switch of No. 3 is used to select input protocol, means changing our model of converter (CONV2-E or CON2-G) Decreasing of address Excluded Attached DIP 4 OFF ON Function of decreasing of address is recommended in working mode as CONV-2E, because in Pelco-D protocol address of cameras start at number 1, while in Bi-phase protocol natomiast w protokole Bi-phase address of cameras start at number 0. Because in pelco-P protocol address start at numer 0, switch should be attached for working mode of CONV-2G. 4. Start-up All connections and configuration of switches, should be made with disconnect the power supply of converter. Should pay attention to correct polarity of RS-485 and Bi-Phase interfaces. Correct working of converter can be determined by LED observing. If device is correct configured and connected, at the time of trying to control from desktop, both LEDs should blink. Ewimar Sp. z o.o. www.ewimar.pl CONV3-A/B rev 1.0 5. List of translated commands Nr Function of Pelco-D Function of Bosch cameras 1 Joystick: UP, DOWN, LEFT, RIGHT, ZOOM, FOCUS, IRIS Start Auto-Pan Start Auto-Scan (limit) Set left limit scan Set right limit scan Call preset 100 Call preset 101 Call preset 124 Call other preset (1~99) Start learn pattern Stop learn pattern Run pattern Set preset 115 Call preset 115 Call preset 102 Start learn pattern Set preset 116 Set preset 122 Set other preset (not described in this table) Set preset 118 Call preset 103 Joystick: UP, DOWN, LEFT, RIGHT, ZOOM, FOCUS, IRIS Start Auto-Pan Start Auto-Scan Set left limit scan Set right limit scan Run tour Run Auto-Tracking Home position, motor calibration Call scene 1~99 Start learn pattern A Stop learn pattern A Run pattern A - continuous Start learn pattern B Stop learn pattern B Run pattern B - continuous Start learn pattern A Edit scene name Edit auto-pan / scan speed Entry do advance scene edit ON 1 ENTER ON 2 ENTER SET 101 ENTER SET 102 ENTER ON 8 ENTER ON 78 ENTER SET 110 ENTER SHOT 1~99 ON 100 ENTER OFF 100 ENTER ON 50 ENTER ON 101 ENTER OFF 101 ENTER ON 52 ENTER ON 100 ENTER ON 62 ENTER ON 14 ENTER SET 100 ENTER Tour Edit Clear alarm SET 900 EDIT OFF 65 ENTER 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Equivalent of command for Bosch keyboard Locked functions 21 Set preset 127 Unlock advanced functions OFF 90 ENTER 22 Call preset 127 Lock advanced functions ON 90 ENTER 23 Call preset 95 Entry to main menu* ON 45 ENTER 24 Call preset 126 Display fast address* ON 997 ENTER 25 Set preset 123 Hide OSD screen* OFF 60 ENTER 26 Call preset 123 Display OSD screen* ON 60 ENTER 27 Set preset 119 Edit park function* ON 9 ENTER 28 Set preset 120 Entry to password menu* SET 802 ENTER 29 Set preset 121 Edit tour time* ON 15 ENTER *) This functions are available before unlocked Advanced Functions – more information you can find on instruction of Bosch cameras. Because cameras, which use Pelco-D protocol have a less function than Bosch keyboards, the converter doesn’t translate commands of Fast addressing. To use this function is recommended uses original Bosch keyboard or hardware addressing. Producer: Ewimar Sp. z o.o., ul. Konaskiego 84, 01-355 Warsaw, Poland, Phone: +48 (22) 6919065, email: [email protected], www.ewimar.pl Ewimar Sp. z o.o. www.ewimar.pl CONV3-A/B rev 1.0
© Copyright 2024