Rosemount 585 Annubar Flanged Flo-Tap Assembly ®

00825-0200-4585_BA.fm Page 1 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
00825-0200-4585, Rev BA
October 2014
Rosemount 585 Annubar® Flanged
Flo-Tap Assembly
00825-0200-4585_BA.fm Page 2 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
NOTICE
This guide provides basic guidelines for Rosemount 585 Annubar. It does not provide instructions for
configuration, diagnostics, maintenance, service, troubleshooting, Explosion-proof, Flame-Proof, or
intrinsically safe (I.S.) installations. Refer to the 585 Annubar Reference Manual (document number
00809-0100-4585) for more instruction. This manual is also available electronically on
www.rosemount.com.
Process leaks may cause harm or result in death. To avoid process leaks, only use gaskets designed to seal
with the corresponding flange and o-rings to seal process connections. Flowing medium may cause the 585
Annubar assembly to become hot and could result in burns.
Contents
585 Annubar Flanged Flo-Tap Assembly
(exploded view). . . . . . . . . . . . . . . . . . . . . . . . . 3
Location and orientation . . . . . . . . . . . . . . . . 4
Weld mounting hardware . . . . . . . . . . . . . . . 8
Install isolation valve . . . . . . . . . . . . . . . . . . . . 9
Mount drilling machine and drill hole . . . 9
2
Remove drilling machine . . . . . . . . . . . . . . . 10
Mount the Annubar . . . . . . . . . . . . . . . . . 10
Insert the Annubar . . . . . . . . . . . . . . . . . . 11
Mount the transmitter. . . . . . . . . . . . . . . 11
Retracting the Annubar. . . . . . . . . . . . . . 16
Product Certifications . . . . . . . . . . . . . . . 17
00825-0200-4585_BA.fm Page 3 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
585 Annubar Flanged Flo-Tap Assembly
(exploded view)
H
I
A
B
C
E
D
F
J
K
G
L
A. Compression Plate
B. Follower
C. Packing
D. Packing Gland
E. Support Plate
F. Isolation Valve
G. Gasket
H. Remote Mount Process Connection
I. Head Plate
J. Cage Nipple
K. Drive Rods
L. Mounting Flange Assembly
Note
Use an appropriate pipe sealing compound rated for the service temperature on all threaded
connections.
3
00825-0200-4585_BA.fm Page 4 Tuesday, October 21, 2014 2:32 PM
October 2014
Quick Start Guide
Step 1: Location and orientation
Correct orientation and straight run requirements must be met for accurate and
repeatable flow measurements. Refer to Table 1 for minimum pipe diameter
distances from upstream disturbances.
Table 1. Straight Run Requirements
1
2
3
4
4
With straightening
vanes
Downstream
dimensions
Upstream dimensions
Without straightening
vanes
In
plane A
Out of
plane A
A
A
A’
C
C’
8
10
N/A
N/A
N/A
4
N/A
N/A
8
4
4
4
11
16
N/A
N/A
N/A
4
N/A
N/A
8
4
4
4
23
28
N/A
N/A
N/A
4
N/A
N/A
8
4
4
4
12
12
N/A
N/A
N/A
4
N/A
N/A
8
4
4
4
00825-0200-4585_BA.fm Page 5 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
Table 1. Straight Run Requirements
Without straightening
vanes
5
6
With straightening
vanes
Downstream
dimensions
Upstream dimensions
In
plane A
Out of
plane A
A
A
A’
C
C’
18
18
N/A
N/A
N/A
4
N/A
N/A
8
4
4
4
30
30
N/A
N/A
N/A
4
N/A
N/A
8
4
4
4
Note

Consult the factory for instructions regarding use in square or rectangular ducts.

“In Plane A” means the bar is in the same plane as the elbow. “Out of Plane A” means
the bar is perpendicular to the plane of the elbow.

If proper lengths of straight run are not available, position the mounting such that
80% of the run is upstream and 20% is downstream.

Use straightening vanes to reduce the required straight run length.

Row 6 in Table 1 applies to gate, globe, plug, and other throttling valves that are
partially opened, as well as control valves.
5
00825-0200-4585_BA.fm Page 6 Tuesday, October 21, 2014 2:32 PM
October 2014
Quick Start Guide
Misalignment
585 Annubar installation allows for a maximum misalignment of 3°.
Figure 1. Misalignment
+
-3
+
-3
+
-3
Horizontal orientation
For proper venting and draining, the sensor should be located in the upper half of
the pipe for air and gas applications. For liquid applications, the sensor should be
located in the bottom half of the pipe. For steam applications, the sensor can be
located on either the top or the bottom of the pipe depending on the
temperature of the steam. See Table on page 16 for more information.
Figure 2. Gas and Steam on Top
Recommended Zone
30
6
00825-0200-4585_BA.fm Page 7 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
Figure 3. Liquid and Steam
30
Recommended Zone
Vertical orientation
The sensor can be installed in any position around the circumference of the pipe
provided the vents are positioned properly for bleeding or venting. Optimal
results for liquid or steam are obtained when flow is up. For direct mount steam
applications, a 90° spacer will be added to provide water legs to ensure the
transmitter stays within temperature limits.
Flow
Figure 4. Steam and Liquid
360
Flow
Figure 5. Gas
360
7
00825-0200-4585_BA.fm Page 8 Tuesday, October 21, 2014 2:32 PM
October 2014
Quick Start Guide
Step 2: Weld mounting hardware
Note
Rosemount-supplied mounting has an integral alignment built into the mounting hardware that
assists in the correct drilling of the mounting hole. It also assists in the alignment of the sensor to
the mounting hole for insertion.
1. At the pre-determined position, place the flanged assembly on the pipe, gap
1
/16-in (1.6 mm), and measure the distance from the outer diameter of the
pipe to the face of the flange. Compare this to Table 2 and adjust the gap as
necessary.
Table 2. Flange Sizes and ODF per Sensor Size
Sensor size
Flange type
44
44
A
Pressure class
Flange size/rating/type
ODF in. (mm)(1)
1
3.0-in. 150# RF
4.63 (117)
3
3.0-in. 300# RF
5.00 (127)
44
6
3.0-in. 600# RF
5.38 (137)
44
1
4.0-in. 150# RTJ
4.82 (122)
3
4.0-in. 300# RTJ
5.25 (133)
6
4.0-in. 600# RTJ
5.44 (138)
44
R
44
1. Tolerances for the ODF dimension above a 10-in. (254 mm) line size is ±0.060-in. (1,5 mm). Below
10-in. (254 mm) line size is ±0.030-in. (0,8 mm).
2. Place four 1/4-in. (6 mm) tack welds at 90° increments. Check alignment of the
mounting both parallel and perpendicular to the axis of flow (see Figure 6). If
alignment of the mounting is within tolerances, finish weld per local codes. If
outside of specified tolerance, make adjustments prior to making the finish
weld.
3. To avoid serious burns, allow the mounting hardware to cool before
continuing.
Figure 6. Alignment
A
B
A. ODF
B. Tack Welds
8
00825-0200-4585_BA.fm Page 9 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
Step 3: Install isolation valve
1. Position the isolation valve onto the mounting flange. Ensure the valve stem is
positioned so that when the Flo-Tap is installed, the insertion rods will straddle
the pipe and the valve handle will be centered between the rods (see Figure 7).
(Note: Interference will occur if the valve is located inline with the rods.)
2. Fasten the isolation valve to the mounting using gasket, bolts, and nuts.
Figure 7. Isolation Valve Orientation
A
A. Isolation valve
Step 4: Mount drilling machine and drill hole
Drilling machine is not provided with assembly.
1. Mount the drilling machine to the isolation valve.
2. Open the valve fully.
3. Drill the hole into the pipe wall in accordance with the instructions provided by
the drilling machine manufacturer. Drill to 2.5 in. (64 mm). Drill hole has a
tolerance of +1/16 / -0 in. (1,6 / -0 mm).
4. Retract the drill fully beyond the valve.
Figure 8. Drilling Assembly
B
A
C
A. Isolation valve is fully open when inserting drill
B. Pressure Drilling Machine
C. Isolation valve is fully closed after withdrawing drill
9
00825-0200-4585_BA.fm Page 10 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
Step 5: Remove drilling machine
1. Verify the drill has been retracted past the valve.
2. Close the isolation valve to isolate the process.
3. Bleed drilling machine pressure and remove.
4. Check isolation valve and mounting for leakage.
Step 6: Mount the Annubar
1. Align the flow arrow on the head with the direction of flow.
2. Use the supplied gaskets and flange bolts to fasten the Flo-Tap assembly to the
isolation valve.
3. Tighten the nuts in a cross pattern to compress the gasket evenly.
4. Ensure the vent valves are closed before proceeding.
5. Open and close the isolation valve to pressurize the 585 sensor and identify
any leak points in the installation. Use extreme caution if the flowing medium
is steam or caustic.
6. Check the entire installation for leakage. Tighten as required to stop any
connection from leaking. Repeat steps 5 and 6 until there is no leakage.
Note
Flo-Tap 585 Annubars have the potential to carry a large amount of weight at a great distance from
the piping, necessitating external support. The support plate has threaded holes to assist in
supporting the 585 Annubar.
Figure 9. Install Flo-Tap Assembly
A
B
A. Support Plate
B. Isolation Valve
10
00825-0200-4585_BA.fm Page 11 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
Step 7: Insert the Annubar
1. Open the isolation valve fully.
2. Rotate the crank clockwise. If a power drill with an adapter is used, do not
exceed 200 revolutions per minute.
3. Continue rotating the crank until the sensor firmly contacts the opposite side
of the pipe.
a. The orange stripes are visual indication of when the sensor is approaching
the opposite side wall.
b. As the orange stripes approach the support plate, remove the power drill
and continue cranking manually. Place a finger above the packing gland
while cranking. Vibration and movement will occur. When vibration and
movements stop, the sensor is in contact with the opposite side wall.
Note
Do not place finger above packing gland for high temperature applications.
c. Turn the handle an additional 1/4 to 1/2 turn to secure the sensor.
Figure 10. Insert the Sensor
A
A. Drive Lock Pin
Step 8: Mount the transmitter
Transmitter mounting, direct mount head without valves
1. Place O-rings into grooves on the face of head.
2. Orient the equalizer valve(s) so they are easily accessible. Install a manifold
with the smooth face mating to the face of the head. Tighten in cross pattern
to a torque of 400 in•lb (45 N•m).
3. Place O-rings into grooves on the face of the manifold.
4. Align the high side of the transmitter to the high side of the sensor (“Hi” is
stamped on the side of the head) and install.
5. Tighten the nuts in a cross pattern to 400 in•lb (45 N•m).
6. If the DV option is selected, Double Instrument Valves will be provided. Repeat
Steps 1-4 to install the redundant transmitter.
11
00825-0200-4585_BA.fm Page 12 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
Transmitter mounting with remote mount head
Temperatures in excess of 250 °F (121 °C) at the sensor module diaphragms will
damage the transmitter. Remote mounted transmitters are connected to the
sensor by means of impulse piping, which allows service flow temperatures to
decrease to a point where the transmitter is no longer vulnerable.
Different impulse piping arrangements are used depending on the process fluid
and must be rated for continuous operation at the pipeline design pressure and
temperature. A minimum of 1/2-in. (12 mm) outer diameter stainless steel tubing
with a wall thickness of at least 0.035-in. (1 mm) is recommended. Threaded pipe
fittings are not recommended because they create voids where air can become
entrapped and create leakage points.
The following restrictions and recommendations apply to impulse piping
location:

Impulse piping that runs horizontally must slope at least one inch per foot
(83mm/m).
- Slope downward (toward the transmitter) for liquid and steam
applications
- Slope upward (toward the transmitter) for gas applications.

For applications with temperature below 250 °F (121 °C), impulse piping
should be as short as possible to minimize temperature changes. Insulation
may be required.

For applications above 250 °F (121 °C), impulse piping should have a minimum
length of one foot (0.3048 m) for every 100 °F (38°C) temperature increase
over 250 °F (121 °C). Impulse piping must be non-insulated to reduce fluid
temperature. Any threaded connections should be checked after the system
reaches the intended temperature because connections may come loose with
contraction and expansion caused by temperature change.

Outdoor installations for liquid, saturated gas, or steam may require insulation
and heat tracing to prevent freezing.

When impulse piping is longer than six feet (1.8 m) the high and low impulse
lines must be positioned together to maintain equal temperature. They must
be supported to prevent sagging and vibration.

Impulse lines should be positioned in protected areas or against walls or
ceilings. Use appropriate pipe sealing compound rated for the service
temperature on all threaded connections. Do not place the impulse piping
near high temperature piping or equipment.
An instrument manifold is recommended for all installations. Manifolds allow an
operator to equalize the pressures prior to zeroing and isolates the process fluid
from the transmitter.
12
00825-0200-4585_BA.fm Page 13 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
Figure 11. Valve Identification for 5-Valve and 3-Valve Manifolds
5-valve manifold
3-valve manifold
To PH
To PH
To PL
To PL
MV
ME
ML
MH
ML
MH
2
2
MEL
MEH
DVL
DVH
DVL
DVH
1
1
Table 3. Description of Impulse Valves and Components
Name
Description
Purpose
Components
1
Transmitter
Reads Differential Pressure
2
Manifold
Isolates and equalizes transmitter
Manifold and Impulse Valves
PH
Primary Sensor(1)
PL
Primary Sensor(2)
DVH
Drain/Vent Valve(1)
DVL
Drain/Vent Valve(2)
MH
Manifold(1)
ML
Manifold(2)
MEH
Manifold
Equalizer(1)
MEL
Manifold
Equalizer(2)
ME
Manifold Equalizer
Allows high and low side pressure to equalize
MV
Manifold Vent Valve
Vents process fluid
High and low side pressure process connections.
Drains (for gas service) or vents (for liquid or steam service) the DP
transmitter chambers
Isolates high side or low side pressure from the process
Allows high and low pressure side access to the vent valve, or for
isolating the process fluid
1. High Pressure
2. Low Pressure
13
00825-0200-4585_BA.fm Page 14 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
Recommended installations
Gas service
Secure the transmitter above the sensor to prevent condensible liquids from
collecting in the impulse piping and the DP cell.
Figure 12. Vertical Line
Figure 13. Horizontal Line
Liquid service
Secure the transmitter below the sensor to ensure that air will not be introduced
into the impulse piping or the transmitter.
Figure 14. Vertical Line
14
00825-0200-4585_BA.fm Page 15 Tuesday, October 21, 2014 2:32 PM
October 2014
Quick Start Guide
Figure 15. Horizontal Line
Steam service (above 450 °F [232 °C])
Mount the transmitter below the process piping. Route the impulse piping down
to the transmitter and fill the system with cool water through the two tee fittings.
Figure 16. Vertical Line
Figure 17. Horizontal Line
15
00825-0200-4585_BA.fm Page 16 Tuesday, October 21, 2014 2:32 PM
October 2014
Quick Start Guide
Steam on top service
Table 4. Steam on Top Temperature Limits
Transmitter connection platform
Maximum temperature
Remote Mount
850 °F (455 °C)
Direct Mount
400 °F (205 °C)
For remote mount installations the impulse piping should slope up slightly from
the instrument connections on the Annubar to the cross fittings allowing
condensate to drain back into the pipe. From the cross fittings, the impulse
piping should be routed downward to the transmitter and the drain legs. The
transmitter should be located below the instrument connections of the Annubar.
Depending on the environmental conditions, it may be necessary to insulate the
mounting hardware.
Figure 18. Horizontal Line
Step 9: Retracting the Annubar
Gear drive (G)
1. Remove the drive lock pin.
2. Rotate the crank counter-clockwise. If a power drill with an adapter is used, do
not exceed 200 rpm.
3. Retract until the rod end nuts are against the gear box mechanism.
16
00825-0200-4585_BA.fm Page 17 Tuesday, October 21, 2014 2:32 PM
October 2014
Quick Start Guide
Product Certifications
European Directive Information
A copy of the EC Declaration of Conformity can be found at the end of the Quick
Start Guide. The most recent revision of the EC Declaration of Conformity can be
found at www.rosemount.com.
Ordinary Location Certification from FM Approvals
As standard, the transmitter has been examined and tested to determine that the
design meets the basic electrical, mechanical, and fire protection requirements
by FM Approvals, a nationally recognized test laboratory (NRTL) as accredited by
the Federal Occupational Safety and Health Administration (OSHA).
Installing Equipment in North America
The US National Electrical Code (NEC) and the Canadian Electrical Code (CEC)
permit the use of Division marked equipment in Zones and Zone marked
equipment in Divisions. The markings must be suitable for the area classification,
gas, and temperature class. This information is clearly defined in the respective
codes.
USA
E5
FM Explosionproof (XP) and Dust-Ignitionproof (DIP)
Certificate: 3008216
Standards: FM Class 3600 – 2011, FM Class 3615 – 2006, FM Class 3616 – 2011,
FM Class 3810 – 2005, ANSI/NEMA 250 – 2003
Markings: XP CL I, DIV 1, GP B, C, D; DIP CL II, DIV 1, GP E, F, G; CL III;
T5(-50 °C  Ta  +85 °C); Factory Sealed; Type 4X
I5
FM Intrinsic Safety (IS) and Nonincendive (NI)
Certificate: 3031960
Standards: FM Class 3600 – 1998, FM Class 3610 – 2007, FM Class 3611 – 2004,
FM Class 3810 – 2005, NEMA 250 – 1991
Markings: IS CL I, DIV 1, GP A, B, C, D; CL II, DIV 1, GP E, F, G; Class III; Class 1,
Zone 0 AEx ia IIC T4; NI CL 1, DIV 2, GP A, B, C, D;
T4(-50 °C  Ta  +70 °C); when connected per Rosemount drawing
03151-1206; Type 4x
Note
Transmitters marked with NI CL 1, DIV 2 can be installed in Division 2 locations using general
Division 2 wiring methods or Nonincendive Field Wiring (NIFW). See Drawing 03151-1206.
17
00825-0200-4585_BA.fm Page 18 Tuesday, October 21, 2014 2:32 PM
October 2014
Quick Start Guide
IE
FM FISCO
Certificate: 3012350
Standards: FM Class 3600 - 2011, FM Class 3610 - 2010, FM Class 3611 - 2004, FM
Class 3616 - 2006, FM Class 3810 - 2005, NEMA 250 - 1991
Markings: IS CL I, DIV 1, GP A, B, C, D; (-50 °C  Ta  +70 °C); when connected per
Rosemount drawing 03151-1006; Type 4x
Canada
E6
CSA Explosionproof, Dust-Ignitionproof, and Division 2
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No. 25-1966,
CSA Std C22.2 No. 30-M1986, CAN/CSA C22.2 No. 94-M91,
CSA Std C22.2 No. 142-M1987, CSA Std C22.2 No. 213-M1987,
ANSI/ISA 12.27.01-2003, CSA Std C22.2 No. 60529:05
Markings: Explosionproof Class I, Division 1, Groups B, C, D; Dust-Ignitionproof
Class II, Division 1, Groups E, F, G; Class III; suitable for Class I, Division
2, Groups A, B, C, D; Type 4x
I6
CSA Intrinsically Safe
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No. 30-M1986, CAN/CSA
C22.2 No. 94-M91, CSA Std C22.2 No. 142-M1987, CSA Std C22.2 No.
157-92, ANSI/ISA 12.27.01-2003, CSA Std C22.2 No. 60529:05
Markings: Intrinsically Safe Class I, Division 1; suitable for Class 1, Zone 0, IIC,
T3C; when connected per Rosemount drawing 03151-1207; Type 4x
IF
CSA FISCO
Certificate: 1143113
Standards: CAN/CSA C22.2 No. 0-10, CSA Std C22.2 No. 30-M1986, CAN/CSA
C22.2 No. 94-M91, CSA Std C22.2 No. 142-M1987, CSA Std C22.2 No.
157-92, ANSI/ISA 12.27.01-2003, CSA Std C22.2 No. 60529:05
Markings: FISCO Intrinsically Safe Class I, Division 1; suitable for Class I, Zone 0;
T3C; when installed per Rosemount drawing 03151-1207; Type 4X
Europe
E1
18
ATEX Flameproof
Certificate: KEMA 00ATEX2143X
Standards: EN 60079-0:2012, EN 60079-1: 2007, EN 60079-26:2007
(3051SFx models with RTD are certified to EN 60079-0:2006)
Markings:
II 1/2 G Ex d IIC T6…T4 Ga/Gb, T6(-60 °C  Ta  +70 °C),
T5/T4(-60 °C  Ta  +80 °C)
Temperature class
Process temperature
T6
-60 °C to +70 °C
T5
-60 °C to +80 °C
T4
-60 °C to +120 °C
00825-0200-4585_BA.fm Page 19 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
Special Conditions for Safe Use (X):
1. The device contains a thin wall diaphragm. Installation, maintenance and use
shall take into account the environmental conditions to which the diaphragm
will be subjected. The manufacturer's instructions for installation and
maintenance shall be followed in detail to assure safety during its expected
lifetime.
2. For information on the dimensions of the flameproof joints the manufacturer
shall be contacted.
I1
ATEX Intrinsic Safety
Certificate: Baseefa08ATEX0064X
Standards: EN 60079-0: 2012, EN 60079-11: 2012
Markings:
II 1 G Ex ia IIC T4 Ga, T4(-60 °C  Ta  +70 °C)
HART®
SuperModule™ only
RTD (for 3051SFx)
Voltage Ui
30 V
7.14 V
30 V
Current Ii
300 mA
300 mA
2.31 mA
Power Pi
1W
887 mW
17.32 mW
14.8 nF
0.11 uF
0
0
0
0
Capacitance Ci
Inductance Li
Special Conditions for Safe Use (X):
1. If the equipment is fitted with the optional 90 V transient suppressor, it is
incapable of withstanding the 500 V isolation from earth test and this must be
taken into account during installation.
2. The enclosure may be made of aluminum alloy and given a protective
polyurethane paint finish; however, care should be taken to protect it from
impact or abrasion if located in a Zone 0 environment.
ND ATEX Dust
Certificate: BAS01ATEX1374X
Standards: EN 60079-0: 2012, EN 60079-31: 2009
Markings:
II 1 D Ex ta IIIC T 105 °C T500 95 °C Da, (-20 °C  Ta  +85 °C),
Vmax = 42.4 V
Special Conditions for Safe Use (X):
1. Cable entries must be used which maintain the ingress protection of the
enclosure to at least IP66.
2. Unused cable entries must be filled with suitable blanking plugs which
maintain the ingress protection of the enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the ambient
temperature range of the apparatus and capable of withstanding a 7 J impact
test.
4. The SuperModule(s) must be securely screwed in place to maintain the ingress
protection of the enclosure(s).
19
00825-0200-4585_BA.fm Page 20 Tuesday, October 21, 2014 2:32 PM
October 2014
Quick Start Guide
N1
ATEX Type n
Certificate: Baseefa08ATEX0065X
Standards: EN 60079-0: 2012, EN 60079-15: 2010
Markings:
II 3 G Ex nA IIC T4 Gc, (-40 °C  Ta  +70 °C), Vmax = 45 V
Special Condition for Safe Use (X):
1. If fitted with a 90 V transient suppressor, the equipment is not capable of
withstanding the 500 V electrical strength test as defined in Clause 6.5.1 of EN
60079-15:2010. This must be taken into account during installation.
International
E7
IECEx Flameproof and Dust
Certificate: IECEx KEM 08.0010X (Flameproof)
Standards: IEC 60079-0:2011, IEC 60079-1: 2007, IEC 60079-26:2006
(3051SFx models with RTD are certified to IEC 60079-0:2004)
Markings: Ex d IIC T6…T4 Ga/Gb, T6(-60 °C  Ta  +70 °C),
T5/T4(-60 °C  Ta  +80 °C)
Temperature class
Process temperature
T6
-60 °C to +70 °C
T5
-60 °C to +80 °C
T4
-60 °C to +120 °C
Special Conditions for Safe Use (X):
1. The device contains a thin wall diaphragm. Installation, maintenance and use
shall take into account the environmental conditions to which the diaphragm
will be subjected. The manufacturer's instructions for installation and
maintenance shall be followed in detail to assure safety during its expected
lifetime.
2. For information on the dimensions of the flameproof joints the manufacturer
shall be contacted.
Certificate: IECEx BAS 09.0014X (Dust)
Standards: IEC 60079-0:2011, IEC 60079-31:2008
Markings: Ex ta IIIC T 105 °C T500 95 °C Da, (-20 °C  Ta  +85 °C), Vmax = 42.4V
Special Conditions for Safe Use (X):
1. Cable entries must be used which maintain the ingress protection of the
enclosure to at least IP66.
2. Unused cable entries must be filled with suitable blanking plugs which
maintain the ingress protection of the enclosure to at least IP66.
3. Cable entries and blanking plugs must be suitable for the ambient
temperature range of the apparatus and capable of withstanding a 7J impact
test.
4. The 3051S- SuperModule must be securely screwed in place to maintain the
ingress protection of the enclosure.
20
00825-0200-4585_BA.fm Page 21 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
I7
IECEx Intrinsic Safety
Certificate: IECEx BAS 08.0025X
Standards: IEC 60079-0: 2011, IEC 60079-11: 2011
Markings: Ex ia IIC T4 Ga, T4(-60 °C  Ta  +70 °C)
HART
SuperModule only
RTD (for 3051SFx)
Voltage Ui
30 V
7.14 V
30 V
Current Ii
300 mA
300 mA
2.31 mA
Power Pi
1W
887 mW
17.32 mW
14.8 nF
0.11 uF
0
0
0
0
Capacitance Ci
Inductance Li
Special Conditions for Safe Use (X):
1. If the equipment is fitted with the optional 90 V transient suppressor, it is
incapable of withstanding the 500 V isolation from earth test and this must be
taken into account during installation.
2. The enclosure may be made of aluminum alloy and given a protective
polyurethane paint finish; however, care should be taken to protect it from
impact or abrasion if located in a Zone 0 environment.
N7
IECEx Type n
Certificate: IECEx BAS 08.0026X
Standards: IEC 60079-0: 2011, IEC 60079-15: 2010
Markings: Ex nA IIC T5 Gc, (-40 °C  Ta  +70 °C)
Special Condition for Safe Use (X):
1. If fitted with a 90 V transient suppressor, the equipment is not capable of
withstanding the 500 V electrical strength test as defined in Clause 6.5.1 of IEC
60079-15:2010. This must be taken into account during installation.
Brazil
E2
INMETRO Flameproof
Certificate: CEPEL 03.0140X [Mfg USA, Singapore, Germany],
CEPEL 07.1413X [Mfg Brazil]
Standards: ABNT NBR IEC 60079-0:2008, ABNT NBR IEC 60079-1:2009, ABNT NBR
IEC 60529:2009
Markings: Ex d IIC T* Ga/Gb, T6(-40 °C  Ta  +65 °C), T5(-40 °C  Ta  +80 °C),
IP66*
Special Conditions for Safe Use (X):
1. For ambient temperature above 60 °C, cable wiring must have minimum
isolation temperature of 90 °C, to be in accordance to equipment operation
temperature.
21
00825-0200-4585_BA.fm Page 22 Tuesday, October 21, 2014 2:32 PM
October 2014
Quick Start Guide
2. The device contains a thin wall diaphragm. Installation, maintenance and use
shall take into account the environmental conditions to which the diaphragm
will be subjected. The manufacturer’s instructions for installation and
maintenance shall be followed in detail to assure safety during its expected
lifetime.
I2
INMETRO Intrinsic Safety
Certificate: NCC 12.1158X [Mfg USA, Germany]
Standards: ABNT NBR IEC 60079-0:2008, ABNT NBR IEC 60079-11:2009,
ABNT NBR IEC 60079-26:2008
Markings: Ex ia IIC T4 Ga, T4(-60 °C  Ta  +70 °C), IP66*
Special Conditions for Safe Use (X):
1. If the equipment is fitted with the optional 90 V transient suppressor, it is
incapable of withstanding the 500 V isolation from earth test and this must be
taken into account during installation.
2. For processes with temperatures above 135 °C, the user must assess whether
the SuperModule temperature class is suitable for such applications, because
in this situation there is a risk of the SuperModule temperature being above
T4.
HART
SuperModule only
RTD (for 3051SFx)
Voltage Ui
30 V
7.14 V
30 V
Current Ii
300 mA
300 mA
2.31 mA
Power Pi
1W
887 mW
17.32 mW
14.8 nF
0.11 uF
0
0
0
0
Capacitance Ci
Inductance Li
China
E3
China Flameproof and Dust Ignition-proof
Certificate: 3051SMV: GYJ14.1039X [Mfg USA, China, Singapore]
3051SFx: GYJ11.1711X [Mfg USA, China, Singapore]
Standards: 3051SMV: GB3836.1-2010, GB3836.2-2010, GB3836.20-2010
3051SFx: GB3836.1-2010, GB3836.2-2010, GB3836.20-2010,
GB12476.1-2000
Markings: 3051SMV: Ex d IIC T6/T5 Ga/Gb
3051SFx: Ex d IIC T6/T5 Ga/Gb; DIP A20 TA 105 °C; IP66
Special Condition for Safe Use (X):
1. Symbol “X” is used to denote specific conditions of use: For information on the
dimensions of the flameproof joints the manufacturer shall be contacted.
22
00825-0200-4585_BA.fm Page 23 Tuesday, October 21, 2014 2:32 PM
October 2014
I3
Quick Start Guide
China Intrinsic Safety
Certificate: 3051SMV: GYJ14.1040X [Mfg USA, China, Singapore]
3051SFx: GYJ11.1707X [Mfg USA, China, Singapore]
Standards: 3051SMV: GB3836.1-2010, GB3836.4-2010, GB3836.20-2010
3051SFx: GB3836.1/4-2010, GB3836.20-2010, GB12476.1-2000
Markings: 3051SMV: Ex ia IIC T4 Ga
3051SFx: Ex ia IIC T4 Ga, DIP A20 TA 105 °C; IP66
Special Conditions for Safe Use (X):
1. The enclosure may contain light metal, attention should be taken to avoid
ignition hazard due to impact or friction.
2. The apparatus is not capable of withstanding the 500 V electrical strength test
defined in Clause 6.3.12 of GB3836.4-2010.
EAC – Belarus, Kazakhstan, Russia
EM Technical Regulation Customs Union (EAC) Flameproof
Certificate: Contact an Emerson Process Management representative for
additional information
IM
Technical Regulation Customs Union (EAC) Flameproof
Certificate: Contact an Emerson Process Management representative for
additional information
Japan
E4
Japan Flameproof
Certificate: TC19070, TC19071, TC19072, TC19073
Markings: Ex d IIC T6
Republic of Korea
EP
Republic of Korea Flameproof
Certificate: 12-KB4BO-0180X [Mfg USA], 11-KB4BO-0068X [Mfg Singapore]
Markings: Ex d IIC T5 or T6
IP
Republic of Korea Intrinsic Safety
Certificate: Contact an Emerson Process Management representative for
additional information
Combinations
K1
Combination of E1, I1, N1, and ND
K2
Combination of E2 and I2
K5
Combination of E5 and I5
K6
Combination of E6 and I6
K7
Combination of E7, I7, and N7
KA
Combination of E1, I1, E6, and I6
KB
Combination of E5, I5, E6, and I6
23
00825-0200-4585_BA.fm Page 24 Tuesday, October 21, 2014 2:32 PM
October 2014
Quick Start Guide
KC
Combination of E1, I1, E5, and I5
KD
Combination of E1, I1, E5, I5, E6, and I6
KM Combination of EM and IM
KP
Combination of EP and IP
Additional Certifications
SBS American Bureau of Shipping (ABS) Type Approval
Certificate: 00-HS145383-6-PDA
Intended Use: Measure gauge or absolute pressure of liquid, gas or vapor
applications on ABS classed vessels, marine, and offshore
installations.
ABS Rules: 2013 Steel Vessels Rules 1-1-4/7.7, 1-1-A3, 4-8-3/1.7, 4-8-3/1.11.1,
4-8-3/13.1
SBV Bureau Veritas (BV) Type Approval
Certificate: 31910/A0 BV
Requirements: Bureau Veritas Rules for the Classification of Steel Ships
Application: Class Notations: AUT-UMS, AUT-CCS, AUT-PORT and AUT-IMS
SDN Det Norske Veritas (DNV) Type Approval
Certificate: A-13243
Intended Use: Det Norske Veritas’ Rules for Classification of Ships, High Speed &
Light Craft, and Det Norske Veritas’ Offshore Standards
Application:
Location classes
Type
3051S
Temperature
D
Humidity
B
Vibration
A
EMC
A
Enclosure
D / IP66 / IP68
SLL Lloyds Register (LR) Type Approval
Certificate: 11/60002(E3)
Application: Environmental categories ENV1, ENV2, ENV3, and ENV5
D3
24
Custody Transfer – Measurement Canada Accuracy Approval
Certificate: AG-0501, AV-2380C
00825-0200-4585_BA.fm Page 25 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
Figure 19. Rosemount 585 Declaration of Conformity
EC Declaration of Conformity
No: DSI 1000 Rev. I
We,
Emerson Process Management
Heath Place - Bognor Regis
West Sussex PO22 9SH
England
declare under our sole responsibility that the products,
Primary Element Models 405 / 1195 / 1595 & Annubar®
Models 485 / 585
manufactured by,
Rosemount / Dieterich Standard, Inc.
5601 North 71st Street
Boulder, CO 80301
USA
to which this declaration relates, is in conformity with the provisions of the European
Community Directives as shown in the attached schedule.
Assumption of conformity is based on the application of the harmonized standards and, when
applicable or required, a European Community notified body certification, as shown in the
attached schedule.
As permitted by 97/23/EC, Annex 7, the authorized signatory for the legally binding declaration of
conformity for Rosemount/Dieterich Standard, Inc. is Vice President of Quality, Timothy J. Layer.
Vice President, Quality
(signature)
20-Oct-2011
Timothy J. Layer
(date of issue)
File ID: DSI CE Marking
Page 1 of 3
DSI 1000I-DoC
25
00825-0200-4585_BA.fm Page 26 Tuesday, October 21, 2014 2:32 PM
October 2014
Quick Start Guide
Schedule
EC Declaration of Conformity DSI 1000 Rev. I
Summary of Classifications
Model/Range
585M - 2500# All Lines
585S - 1500# & 2500# All Lines
MSL46 - 2500# All Lines
MSR: 1500# & 2500# All Lines
1195, 3051SFP, 3095MFP: 150# 1-1/2͇
PED Category
Group 1
Group 2
Fluid
Fluid
N/A
SEP
III
SEP
N/A
SEP
III
SEP
I
SEP
DNF - 150# 1-1/4”, 1-1/2” & 2͇
II
II
I
I
I
SEP
DNF - 300# 1-1/4”, 1-1/2” & 2͇
DNF, DNT, & DNW: 600# 1-1/4”, 1-1/2” & 2”
Flanged ̽ 485/3051SFA/3095MFA: 1500# & 2500# All Lines
II
II
II
I
I
SEP
FloTap ̽ 485/3051SFA/3095MFA: Sensor Size 2 150# 6͇to 24͇ Line
I
SEP
FloTap ̽ 485/3051SFA/3095MFA: Sensor Size 2 300# 6͇to 24͇ Line
II
I
FloTap ̽ 485/3051SFA/3095MFA: Sensor Size 2 600# 6͇to 16͇ Line
II
I
FloTap ̽ 485/3051SFA/3095MFA: Sensor Size 2 600# 18͇to 24͇ Line
III
II
1195, 3051SFP, 3095MFP: 300# & 600# 1-1/2͇
1195, 3051SFP, 3095MFP: 1-1/2” Threaded & Welded
FloTap ̽ 485/3051SFA/3095MFA: Sensor Size 3 150# 12͇to 44͇ Line
II
I
FloTap ̽ 485/3051SFA/3095MFA: Sensor Size 3 150# 46͇to 72͇ Line
III
II
FloTap ̽ 485/3051SFA/3095MFA: Sensor Size 3 300# 12” to 72͇ Line
III
II
FloTap ̽ 485/3051SFA/3095MFA: Sensor Size 3 600# 12͇to 48͇ Line
III
II
FloTap ̽ 485/3051SFA/3095MFA: Sensor Size 3 600# 60͇ to 72͇ Line
IV*
III
PED Directive (97/23/EC)
Models: 405 / 485 / 585/ 1195 / 1595
QS Certificate of Assessment – CE-0041-H-RMT-001-10-USA
IV* Flo Tap - 485/3051SFA/3095MFA: Sensor Size 3 600# 60" to 72" Line (Category IV Flo Tap will require a B1
Certificate for design examination and H1 Certificate for special surveillance)
All other models:
Sound Engineering Practice
File ID: DSI CE Marking
26
Page 2 of 3
DSI 1000I-DoC
00825-0200-4585_BA.fm Page 27 Tuesday, October 21, 2014 2:32 PM
Quick Start Guide
October 2014
Schedule
EC Declaration of Conformity DSI 1000 Rev. I
Pressure Equipment Directive (93/27/EC) Notified Body:
Bureau Veritas UK Limited [Notified Body Number: 0041]
Parklands, Wilmslow Road, Didsbury
Manchester M20 2RE
United Kingdom
File ID: DSI CE Marking
Page 3 of 3
DSI 1000I-DoC
27
00825-0200-4585_BA.fm Page 28 Tuesday, October 21, 2014 2:32 PM
?00825-0200-4585?
Quick Start Guide
00825-0200-4585, Rev BA
October 2014
Emerson Process Management
Rosemount Inc.
Emerson Process Management
Latin America
8200 Market Boulevard
Chanhassen, MN USA 55317
T (US) (800) 999-9307
T (Intnl) (952) 906-8888
F (952) 906-8889
1300 Concord Terrace, Suite 400
Sunrise, Florida 33323 USA
Tel + 1 954 846 5030
www.rosemount.com
Emerson Process Management
Asia Pacific Private Limited
1 Pandan Crescent
Singapore 128461
T (65) 6777 8211
F (65) 6777 0947/65 6777 0743
Emerson Process Management
GmbH & Co. OHG
Argelsrieder Feld 3
82234 Wessling Germany
T 49 (8153) 9390, F49 (8153) 939172
Beijing Rosemount Far East
Instrument Co., Limited
No. 6 North Street, Hepingli,
Dong Cheng District
Beijing 100013, China
T (86) (10) 6428 2233
F (86) (10) 6422 8586