Sampling Technology

Sampling Technology
Made in Germany
MAXX
Mess- und Probenahmetechnik GmbH
content
02 | 03
The future of
sampling systems
· 15 years MAXX
· Project references
· Project business
· Our dosing systems
· Fixed site samplers SP 5 line
· Portable samplers TP 5 line
04
06
08
10
16
22
our company
04 | 05
innovation
competence
flexibility
reliability
quality
1997–2012: 15 years MA XX
Sampling is our world – difficult applications are our daily challenge. Solutions
are elaborated according to the principle: the simpler, the better.
We think about sampling systems for the future. Continuously we work on
new ideas – always call them in question in order to find even better solutions.
Our ingenuity is documented by our numerous patents and registered utility
models.
Our production is perfectly organized. We work according to a very flexible and
extremely effective production system. This system assures high variability,
fast processing times and best quality. Our working time model is also very
flexible – adapted to our production system. Our delivery time for standard
devices is only a few days.
After only a few years we are one of the world´s biggest manufacturer of
samplers. We offer the widest range of products – from the smallest portable
device up to a complete container station. And we are profitable – which is
absolutely necessary for further growth and consolidation of the company.
The business was created in 1997 by the former management team of the
company Edmund Bühler - the market leader in sampling technique at that
time. The Managing Director, the Sales Manager, the Technical Director, the
Head of Service Department and almost all members of the Sales Team are
on the staff of MAXX today.
Since the foundation of the company we intensively have taken care of the
special wishes of our customers. The more difficult the task, the bigger the
challenge to find the best solution.
In the meantime our units are installed all over the world – in the coldest
regions in Russia as well as under the hot Brazilian sun.
We are competent in all fields: from sampling up to the networking of units,
data acquisition, data transfer and further processing.
We are certified according to ISO 9001:2008. Quality is our leading principle
as only satisfied customers will recommend us. A big part of our success is
based on the reliability of our devices.
project references
06 | 07
São Paulo, Brazil
In Brazil we successfully contributed to the establishment of a water quality measuring net in the State of São
Paulo – from the planningup to the putting into service of
up to now 14 container stations. For this difficult project
MAXX supplied the whole sampling technique as well as
the complete systems for data collection, data storage,
data transfer and data administration.
Leather industry in the North of Italy
MAXX supplied devices for a very special requirement on
the sampling technique: the sample extraction under
changing pressure/vacuum conditions, a very problematic waste water and extensive demands on the software.
Federal Agency for Hydrology in Coblenz
The Federal Agency for Hydrology (BfG) decided to buy
special units from MAXX in order to renew the
measuring and sampling network all over Germany.
Devices with high technical demands, 36 bottles (each
with a volume of 2,5 l), XY-distributor, remote control
by means of a modem, automatic data collection etc.
Chemical Industry
One of the biggest chemical companies in Europe
decided to use the MAXX sampling technique. Samplers
with ceramic slides which almost withstand everything:
pressure, high temperatures, abrasive material, acids ...
Water Quality Agency in Worms
For monitoring of the river Rhine we supplied MAXX selfemptying samplers to the state office to replace Bühler
stations which were placed out of service.
Food Industry in the South of Italy
We have designed and supplied devices for the
governmental monitoring of industrial companies in
the region of Naples which enabled the Federal
Authorities to control the factories round the clock
with only a minimal need of personnel.
Petrochemical Industry
To meet the severe safety requirements for devices
installed in the petrochemical industry, we designed
automatic samplers without any electric components.
project business
08 | 09
Since the foundation of the company we intensively have taken care of the
special wishes of our customers. The more difficult the task, the bigger the
challenge to find the best solution.
Some examples:
Task
Devices for river monitoring with 36 bottles. With additional function keys for special
functions and XY-Distributor. Data fetch and parameterization is effected via
remote function with modem. With a Special software for easy data management.
Task
The sampler had to have 4 x 60 l containers. There had to be two telescopic
drawers, each with two containers. To empty the containers, they had to have a
discharge valve. The samples should be extracted from two different sewers by
means of separate sampling systems and a parallel dosing into the containers
Task
For a hydrocyclone test facility the control unit with the respective software should
be built according to the customer´s specifications. In the framework of a research
series this unit was needed to find out which substances can be separated under
which conditions
Task
Sample extraction from a pressurised line. As the extraction point is in explosive
atmosphere every component on site has to be explosion-proof. The control unit can
be installed at a distance of 20 m in the non-hazardous area. The sample has to be
filled in two bottles.
Task
Sampling from a pressurised line filled with rape oil, pressure 4 bar, temp. 60° C. Air
must not enter the pressurised line. Sampling system and distributor are in the
hazardous area.
our dosing systems
10 | 11
vacuum system
a) Plastic dosing vessel
b) Glass dosing vessel
Probably the most common system in Europe, The sample is extracted by means
of a vacuum, that means the liquid is sucked up through the sample hose and led
into a metering vessel in which the sample volume is adjusted.
Advantages:
· very reliable
· well--proven system since thousand systems in use
· with purge cycle
· gentle samle extraction
· almost no wear
· low operation expenses
Disadvantages:
· stripping effect
· max. 8,5 m suction height
var vaccum system with automatic volume adjustment
Like the standard vacuum system, however, with automatic adjustment of
the sample volume. This system is of interest if samples shall be taken flowproportional with a fixed interval. With this system it is possible to monitor
changes in water quality even at low flow rates as in standard flow-proportional
sampling the sampling intervals are very long. With the new developed
measuring tube system (registered design) a high, reproducible dosing
accuracy is possible.
our dosing systems
12 | 13
flow-through-system
This is a sampling system similar to the water switch. The advantage
is, high volume accuracy, as the sample volume is metered before releasing
to the sample bottle (range = 3–20l/min).
Advantages:
· suitabable for variable inflow
· also applicable with pressurised lines
· high dosing accuracy
· low maintenance
Disadvantages:
· only applicable at free inflow
· limited flow (max. 3-20 l/min)
peristaltic pump
Probably worldwide the most common system. The use of a peristaltic pump
is technically the easiest way to pump sample liquid. Just by changing the
rotating direction of the pump there is a purge and a suction cycle without the
need of any additional parts like valves etc.
Advantages:
·
·
·
·
simple construction
well-proven since thousands of units in use
almost no wear parts
flow-dependent sampling is possible
Disadvantages:
· increased wear if solids are in pump
· higher operation expenses
· pump capacity is influenced by hose again and temperature variations
our dosing systems
14 | 15
double valve system for pressurised lines
System for sampling from pressurised lines for sample medium with high solids
content (sludge). Both ball valves are normally closed. For taking a sample the
valve which is next to the pressure line opens and the tube between the valves is
being filled with water. After that the valve closes again and the other opens and
the sample can flow out into the sampling bottle.
Advantages:
· Working like a standard Vacuum-Sampler. Because of pre- and post-purge of the
connection-line between pressurized line and sampling-device the “dead”-volume”
is almost zero.
· No Level Electrodes, thus the system can work even with oil or other liquids with
low conductivity.
· Available either as a wall mounted version or even with stainlessd steel housing with
cooling and distributor for multiple bottles.
· Working pressure up to 25 bar
Disadvantages
· only fix sampling volume
special dosing systems
In addition to our standard program, we also offer more specific dosing systems, like ceramic slides, systems
for volatiles (VOC) etc. for difficult issues in sampling.
fixed site samplers
SP 5 line
16 | 17
SP5 B
Compact device in plastic housing, especially suitable for high ambient temperatures.
Type:
Housing:
Thermostatic control:
Control:
Data logger:
Programming:
Interface:
Communication:
Languages:
Signal inputs:
Signal outputs:
Sampling method:
Suction height:
Pumping speed:
Suction hose:
Sampling modes:
Bottle variants:
Overall dimensions:
Weight:
Power supply:
Power requirement:
Ambient temperature:
Sample temperature:
Standards:
fixed site sampler
PE with 50 mm insulation/PS/PC (GF10)
self-contained, controlled cooling/heating with 4 settings,
no-frost. Temperature in sample compartment: 4° C
(adjustable from 0,0–9,9° C)
microprocessor control, foil keyboard (128 x 64 Pixel), back lit
3000 entries, nonvolatile data memory; expandable to 32GB
12 freely programmable user programs, with function to link
programs.
Mini-USB, RS422/485, RS 232; optional: Ethernet RJ45
optional in combination with PC software, LAN/WLAN TCP/IP
multi-language, selectable
2 x analogue: 0/4-20 mA,
8 x digital (flow, event, 1 inputs can be programmed freely)
option: expandable with 4x digital, 3 inputs can be programmed
freely, and 8x analogue 0–20 mA or 0–10 V, Impuls length 60ms,
switching level 7–24 V, max. working restistance 500 Ohm,
max. length of signalcable 30 m
8 digital outputs, 1x of them as collective malfunction message
option: expandable with 8 digital, 5 are freely programmable
vacuum system 20–350 ml
option: vacuum VAR flow-proportional system 5–250 ml
option: peristaltic pump
max. 7,5 m (at 1.013 hPa and stagnant medium), optional 8,5 m
> 0,5 m/s at suction height up to at least 6 m (at 1.013 hPa);
pump capacity can be adjusted electronically
PVC, L=7,5 m, ID = 10 mm (max. hose length 30 m.)
time, flow-dependent, event-related and manual sample extraction.
option: flow-proportional
plastic: 1 x 25 L; 4 x 14 L; 4 x 10 L;12 x 2,9 L; 24 x 1 L; 24 x 1 L
glass: 12 x 2 L; 24 x 1L
(hxwxd)
1.100 (1.640 with opened top) x 760 x 775 mm
approx. 75 kg with composite container, higher weight when
using several bottles and/or glass bottles
230 V/115 V/AC
approx. 350 VA (with cooling)
-20°–45° C
0°–40° C
CE; sampling according to ISO 5667-2/3-10
fixed site samplers
18 | 19
SP5 S
Sampler in stainless steel housing. Also available with measuring rack
as measuring station.
Type:
Housing:
Thermostatic control:
Patented pinch valve
Control:
Data logger:
Programming:
Interface:
Communication:
Languages:
Signal inputs:
Non-contact filling level
sensor (option)
Signal outputs:
Sampling method:
Suction height:
Pumping speed:
Suction hose:
Sampling modes:
Bottle variants:
Overall dimensions:
Weight:
Power supply:
Power requirement:
Ambient temperature:
Sample temperature:
Standards:
fixed site sampler
stainless steel with 40 mm insulation,
material: 1.4301/SS304/PS/PC (Gf10) option:
material 1.4571/SS316Ti; SS304 or SS316Ti EPOXY-coated
self-contained, controlled cooling/heating with 4 settings,
no-frost. Temperature in sample compartment: 4° C
(adjustable from 0,0°–9,9° C)
microprocessor control, foil keyboard (128 x 64 Pixel), back lit
3000 entries, nonvolatile data memory; expandable to 32GB
12 freely programmable user programs, with function to link programs.
Mini-USB, RS422/485, RS 232; optional: Ethernet RJ45
optional: Modbus, connection via DP PROFIBUS: LAN/WLAN TCP/IP,
in combination with PC software
multi-language, selectable
2 x analogue: 0/4-20 mA,
8 x digital (flow, event, 1 inputs can be programmed freely)
option: expandable with 4x digital, 3 inputs can be programmed
freely, and 8x analogue 0–20 mA or 0–10 V, Impuls length 60ms,
switching level 7–24 V, max. working restistance 500 Ohm,
max. length of signalcable 30 m
8 digital outputs, 1x of them as collective malfunction message
option: expandable with 8 digital, 5 are freely programmable
vacuum system 20–350 ml, (option: 20–500)
option: vacuum VAR flow-proportional system 5–250 ml
option: bypass system 20–250 ml
option: peristaltic pump
max. 7,5 m (at 1.013 hPa and stagnant medium),
optional 8,5 m (resp. 15m!)
> 0,5 m/s at suction height up to at least 7,8 m (at 1.013 hPa);
pump capacity can be adjusted electronically
PVC, L = 7,5 m, ID = 12 mm (max. hose length 30 m)
time, flow-dependent, event-related and manual sample extraction.
option: flow-proportional
plastic: 1 x 25 L; 1 x 50 L; 2 x 10 L; 4 x 6 L; 4 x 10 L; 4 x 14 L; 12 x 2,9 L
glass: 12 x 2 L; 24 x 1 L
standard (hxwxd):1.290 (1.890 with opened top) x 690 x 645 mm
as measuring station: 1.470 (2.070 with opened top) x 690 x 645 mm
approx. 100 kg with composite container, higher weight when
using several bottles and/or glass bottles
230 V/115 V/AC
approx. 350 VA (with cooling)
-20°–43° C
0°–40° C
CE; sampling according to ISO 5667-2/3-10
SP5 A
Ideal for automatic and continuous operation without the need of personnel.
Also available with measuring rack.
Type:
Housing:
Thermostatic control:
Bottle outlet valve
Control:
Data logger:
Programming:
Interface:
Communication:
Languages:
Signal inputs:
Dosing/rinsing head
Signal outputs:
Sampling method:
Suction height:
Pumping speed:
Suction hose:
Sampling modes:
Bottle variants:
Overall dimensions:
Weight:
Power supply:
Power requirement:
Ambient temperature:
Sample temperature:
Standards:
self-emptying fixed site sampler
stainless steel with 40 mm insulation
material: 1.4301/SS304, PS/PC (GF10)
option: material 1.4571/SS316Ti; SS304 or SS316Ti EPOXY-coated
self-contained, controlled cooling/heating with 4 settings,
no-frost. Temperature in sample compartment: 4° C
(adjustable from 0,0–9,9° C)
microprocessor control, foil keyboard (128 x 64 Pixel), back lit
3000 entries, nonvolatile data memory; expandable to 32GB
12 freely programmable user programs, with function to link programs.
Mini-USB, RS422/485, RS 232; optional: Ethernet RJ45
optional: Modbus, connection via DP PROFIBUS:LAN/WLAN TCP/IP,
in combination with PC software
multi-language, selectable
2 x analogue: 0/4–20 mA,
8 x digital (flow, event, 1 inputs can be programmed freely)
option: expandable with 4x digital, 3 inputs can be programmed
freely, and 8x analogue 0–20 mA or 0–10 V, Impuls length 60ms,
switching level 7–24 V, max. working restistance 500 Ohm,
max. length of signalcable 30 m
8 digital outputs, 1x of them as collective malfunction message
option: expandable with 8 digital, 5 are freely programmable
vacuum system 20–350 ml, (option: 20–500)
option: vacuum VAR flow-proportional system 5–250 ml
option: bypass system 20–250 ml
option: peristaltic pump
max. 7,5 m (at 1.013 hPa and stagnant medium),
optional 8,5 m (resp. 15m!)
> 0,5 m/s at suction height up to at least 7,8 m (at 1.013 hPa);
pump capacity can be adjusted electronically
PVC, L = 7,5 m, ID = 12 mm, (max. hose length 30 m.)
time, flow-dependent, event-related and manual sample extraction.
option: flow-proportional
2 x 10 L PE; 4 x 5 L PE; 12 x 1,6 L glass Duran50
option: 24 x 2 L glass Duran50
(hxwxd) 2 x 10 L; 4 x 5 L; 12 x 1,6 L:
1.290 (1.930 with opened top) x 690 x 645 mm; or
24 x 2 L: 1.400 (2.175 with opened top) x 800 x 850 mm
approx. 115 kg with bottle option 2 x 10 L PE, higher weight with
other bottles and/or glass bottle option.
230 V/115 V/AC
approx. 350 VA (with cooling)
-20°–43° C
0°–40° C
CE; sampling according to ISO 5667-2/3-10
fixed site samplers
20 | 21
SP5 DK
Wall-mounted device for sampling of sludge and from pressurised
lines up to 16 bar.
Type:
Housing:
Thermostatic control:
Control:
Data logger:
Programming:
Interface:
Communication:
Languages:
Signal inputs:
Signal outputs:
Sampling method:
Suction hose:
Sampling modes:
Bottle variants:
Overall dimensions:
Weight:
Power supply:
Power requirement:
Ambient temperature:
Sample temperature:
Standards:
fixed site sampler for sample medium with high solids content
(sludge sampler) and for sampling from pressurised lines
version without housing (PVC/stainless steel)
option: Stainless steel housing with cooling/heating
(materials:1.4301/SS304; 1.4571/SS316Ti; SS34 EPOXYcoated; SS316 Ti EPOXY-coated)
in combination with stainless steel housing: Self-contained,
controlled cooling/heating with 4 settings, no-frost.
temperature in sample compartment: 4° C (adjustable from 0,0–9,9° C)
microprocessor control, foil keyboard (128 x 64 Pixel), back lit
3000 entries, nonvolatile data memory; expandable to 32GB
12 freely programmable user programs, with function to link programs.
Mini-USB, RS422/485, RS 232; optional: Ethernet RJ45
optional: Modbus, connection via DP PROFIBUS: LAN/WLAN TCP/IP,
in combination with PC software
multi-language, selectable
2 x analogue: 0/4–20 mA,
8 x digital (flow, event, 1 inputs can be programmed freely)
option: expandable with 4x digital, 3 inputs can be programmed
freely, and 8x analogue 0–20 mA or 0–10 V, Impuls length 60ms,
switching level 7–24 V, max. working restistance 500 Ohm,
max. length of signalcable 30 m
8 digital outputs, 1x of them as collective malfunction message
option: expandable with 8 digital, 5 are freely programmable
double ball valve system with dosing tube mounted between the
two valves (up to 16 bar). Standard volume 100 ml, other
volumes available upon request
inlet: inside thread 1 1/4” outlet: hose nozzle DN40
other dimensions possible at small volumes
time, flow-dependent, event-related and manual sample extraction.
1 x 25 L PE
in stainless steel housing:
1 x 25 L PE; 4 x 14 L PE; 4 x 6,3 L PE; 12 x 2,9 L PE
wall-mounted version:
control unit (hxwxd) 350 x 450 x 170 mm
dosing unit (hxwxd) 570 x 120 x 200 mm
version in stainless steel housing (hxwxd)
1.470 (2.245 with opened top) x 690 x 645 mm
approx. 15 kg (wall-mounted version);
min. 100 kg (version with stainless steel housing)
230 V/115 V/AC
approx. 50 VA; with cooling approx. 350 VA
0°–45° C
0°–40° C
CE
SP4 Zone 2
Sampler in stainless steel housing for hazardous areas of Zone II.
Explosion protection class: II 3D EEX nC/R/L IIB T3.
Type:
Housing:
Thermostatic control:
Patented 3/4 valve system
Control:
Data logger:
Programming:
Interface:
Communication:
GSM modem:
Languages:
Signal inputs:
Dosing unit with bayonet
fixing
Signal outputs:
Sampling method:
Suction height:
Pumping speed:
Suction hose:
Sampling modes:
Bottle variants:
Overall dimensions:
Weight:
Power supply:
Power requirement:
Ambient temperature:
Sample temperature:
Standards:
fixed site sampler
stainless steel with 40 mm insulation, material: 1.4301/SS304
option: material 1.4571/SS316Ti; SS304 or
SS316Ti EPOXY-coated
self-contained, controlled cooling/heating with 1 setting,
no-frost. Temperature in sample compartment: 4° C
(adjustable from 0,0–9,9° C)
Microprocessor control, foil keyboard, back lit four-line LC-display
1.200 entries; nonvolatile data memory
6 user programs (can be edited freely)
RS232, RS485 (not connected due to ATEX certification)
not connected due to ATEX certification
optional (in combination with PC software)
pay attention to explosion protection!
multi-language, selectable
1x analogue: 4–20 mA, optional 0–20 mA (galvanically separated)
5 x digital (flow, event, 3 inputs can be programmed freely)
pay attention to explosion protection!
max. 8 digital outputs, depending on device version; freely
programmable
vacuum system 20–350 ml
option: vacuum system 20–500 ml
max. 6 m (at 1.013 hPa and stagnant medium)
> 0,5 m/s at suction height up to at least 3 m (at 1.013 hPa);
pump capacity can be adjusted electronically
PVC, L = 7,5 m, ID = 10 mm (max. hose length 20 m.)
time, flow-dependent, event-related and manual sample extraction.
option: flow-proportional
plastic: 1 x 25 L; 1 x 50 L; 2 x 10 L; 4 x 6 L; 4 x 10 L; 4 x 14 L; 12 x 2,9 L
glass: 12 x 2 L
(hxwxd)
1.470 (2.245 with opened top) x 690 x 645 mm
approx. 100 kg with composite container, higher weight when
using several bottles and/or glass bottles
230 V/115 V/AC
approx. 350 VA (with cooling)
-20°–43° C
0°–40° C
CE; sampling according to ISO 5667-2/3-10
portable samplers
TP 5 line
22 | 23
TP 5 C
Compact device with integrated distributor and diverse bottle options.
Insulating box with passive or active cooling.
Type:
Housing:
Thermostatic control:
Control:
Combinations
Data logger:
Programming:
Interface:
Communication:
Languages:
Signal inputs:
Signal outputs:
Sampling method:
Suction height:
Pumping speed:
Suction hose:
Sampling modes:
Bottle variants:
Overall dimensions:
Weight:
Power supply:
Power requirement:
Number of samples:
Ambient temperature:
Sample temperature:
Standards:
Device with optional isobox, active cooling
portable sampler
PE/PC (GF10)
insulated lower part (sample compartment, insulation 40 mm)
option: freezer packs (200 x 10 x 8 mm)
option: compressor cooling (12 V/115 V/230 V)
microprocessor control, foil keyboard, graphical display
(128 x 64 Pixel), back lit
3000 entries, nonvolatile data memory; expandable to 32GB
12 freely programmable user programs, with function to link
programs.
Mini-USB, RS422/485, RS 232; optional: Ethernet RJ45
optional in combination with PC software, LAN/WLAN TCP/IP
multi-language, selectable
2 x analogue: 0/4–20 mA
8 x digital (flow, event, 1 inputs can be programmed freely)
8 digital outputs, 1x of them as collective malfunction message
option: expandable with 8 digital, 5 are freely programmable
Vacuum system 20–350 ml;
Vacuum VAR (variable) system 5–250 ml; Peristaltic pump
max. 6,5 m (at 1.013 hPa); option: 8 m
> 0,5 m/s at suction height up to at least 5 m (at 1.013 hPa);
pump capacity can be adjusted electronically
PVC, L = 5 m, ID = 10 mm (max. hose length 20 m.)
time, flow-dependent, event-related and manual sample extraction
option: flow-proportional
1 x 10 L; 1 x 25 L, 2 x 13 L; 4 x 5 L; 16 x 1 L PE incl. freezer packs /
24 x 1 L PE (standard version)
787 x 510 x 468 mm (hxwxd) / Insulating box passive
1.028 x 550 x 468 mm (hxwxd)/ Insulating box active
approx. 25 kg: Isobox with passive cooling (24 x 1 L)
approx. 40 kg; Isobox with active cooling (24 x 1 L)
(Device incl. battery, empty bottles but no suction hose)
12 V/10 Ah lead storage battery, 115 V or 230 V battery charger
up to 2.000 sample extractions per battery charge, according to
ambient conditions. Power requirement with option “active cooling”
according to ambient conditions.
approx. 2000 sample extractions per battery charge
0°–45° C
0°–40° C
CE, sampling according to ISO 5667-2/3-10
portable samplers
24 | 25
TP 5 P
Compact device which can be combined with any composite container or an
insulating box with active or passive cooling.
Type:
Housing:
Thermostatic control:
Control:
Data logger:
Programming:
Interface:
Communication:
Languages:
Signal inputs:
Signal outputs:
Dosing unit with bayonet
fixing
Sampling method:
Suction height:
Pumping speed:
Suction hose:
Sampling modes:
Bottle variants:
Overall dimensions:
Weight:
Power supply:
Power requirement:
Number of samples:
Ambient temperature:
Sample temperature:
Standards:
Device with optional isobox, passive cooling
portable sampler
PE/PC (GF10)
option: in combination with insulating box,freezer packs or
compressor cooling (12 V/115 V/230 V)
microprocessor control, foil keyboard, graphical display
(128 x 64 Pixel), back lit
3000 entries, nonvolatile data memory; expandable to 32GB
12 freely programmable user programs, with function to link programs.
Mini-USB, RS422/485, RS 232; optional: Ethernet RJ45
optional in combination with PC software, LAN/WLAN TCP/IP
multi-language, selectable
2 x analogue: 0/4–20 mA
8 x digital (flow, event, 1 inputs can be programmed freely)
8 digital outputs, 1x of them as collective malfunction message
option: expandable with 8 digital, 5 are freely programmable
vacuum system 20–350 ml
max. 6,5 m (at 1.013 hPa); option: 8 m
> 0,5 m/s at suction height up to at least 5 m (at 1.013 hPa);
pump capacity can be adjusted electronically
PVC, L = 5 m, ID = 10 mm (max. hose length 20 m.)
time, flow-dependent, event-related and manual sample extraction
option: flow-proportional
1 x 10 L; 1 x 25 L, 2 x 13 L; 4 x 5 L; 16 x 1 L PE incl. freezer packs /
24 x 1 L PE
sampler 442 x 445 x 222 mm (hxwxd); Isobox with passive cooling
534 x 510 x 430 mm; Isobox with active cooling 775 x 550 x 468 mm
sampler: approx. 10 kg; Isobox, passive cooling (24 x 1 L):
approx. 11 kg; Isobox, active cooling (24 x 1 L): approx. 25 kg
230 V / 115 V / AC
up to 2.000 sample extractions per battery charge, according to
ambient conditions. Power requirement with option “active cooling”
according to ambient conditions
approx. 2000 sample extractions per battery charge
0°–45° C
0°–40° C
CE, sampling according to ISO 5667-2/3-10
TP 5 W
Wall-mounted device which can be combined with any composite
container or refrigerator.
Type:
Housing:
Thermostatic control:
Control:
Data logger:
Programming:
User friendly software
Interface:
Communication:
Languages:
Signal inputs:
Signal outputs:
Non-contact filling level
sensor (option)
Sampling method:
Suction height:
Pumping speed:
Suction hose:
Sampling modes:
Bottle variants:
Overall dimensions:
Weight:
Power supply:
Power requirement:
Ambient temperature:
Sample temperature:
Standards:
wall-mounted sampler
PE/PC (GF10)
no
option: refrigerator
microprocessor control, foil keyboard,
graphical display (128 x 64 Pixel), back lit
3000 entries, nonvolatile data memory; expandable to 32GB
12 freely programmable user programs, with function to
link programs.
Mini-USB, RS422/485, RS 232; optional: Ethernet RJ45
optional in combination with PC software, LAN/WLAN TCP/IP
multi-language, selectable
2 x analogue: 0/4–20 mA
8 x digital (flow, event, 1 inputs can be programmed freely)
8 digital outputs, 1x of them as collective malfunction message
option: expandable with 8 digital, 5 are freely programmable
vacuum system 20–350 ml
max. 6,5 m (at 1.013 hPa), option: 8 m
> 0,5 m/s at suction height up to at least 5 m (at 1.013 hPa);
pump capacity can be adjusted electronically
PVC, L = 5 m, ID = 10 mm (max. hose length 20 m.)
time-, flow-dependent, event-related and manual sample extraction
option: flow-proportional
composite container
sampler 362 x 442 x 222 mm (hxwxd)
approx. 10 kg
230 V / 115 V / AC
approx. 25 VA
0°–45° C
0°–40° C
CE, sampling according to ISO 5667-2/3-10
notes
26 | 27
MAXX
Mess- und Probenahmetechnik GmbH
MAXX GmbH
Hechinger Straße 41
72414 Rangendingen/Germany
Phone +49 (0)7471 98481 0
Fax +49 (0)7471 9848144
www.maxx-gmbh.com
[email protected]