COMMERCIAL PROTECTOR SYSTEM® EDGE INTERFACE MODEL CPS-EI APPLICATION This device is intended for use with LiftMaster Logic commercial door operators and compatible 4-wire monitored sensing edges. This is a stand-alone reversing system and is not intended to be used in conjunction with any additional entrapment protection devices. A junction box (not provided) is recommended to protect exposed wiring. To reduce the risk of SERIOUS INJURY or DEATH: • This device is for use ONLY on LiftMaster® Commercial Door Operators. • Disconnect power BEFORE installing the Commercial Protector System® Edge Interface. • Read and follow ALL instructions. INSTALL THE CPS-EI SYSTEM IMPORTANT INFORMATION ABOUT THE ENTRAPMENT PROTECTION DEVICES Be sure power to the operator is disconnected. When properly installed and connected, the system will detect an obstacle in the path of the door sensing edge and reverse the door if activated. If an obstruction is detected while the door is closing, the door will stop and reverse to the fully open position. Junction Box CPS-EI Install 4-Wire Sensing Edge as per manufacturer instructions. Compatible Edges: 65-ME123 4, 65-ME113 4, 65-8203 2, 65-8204 4 RECOMMENDED INSTALLATION 1. Disconnect power to the operator. 2. Mount junction box on the wall half way up the door opening. 3. Attach 4-wire coil cord from sensing edge to junction box and secure in place with the strain relief provided. See wiring diagram below for sensing edge connections. 4. Run 2 wires from the CPS-EI and connect to the operator as shown in the wiring diagrams on the next page. NOTE: Run all wires to the operator through conduit following all local and National Electric Code. Do not run CPS-EI and power wiring in the same conduit. Connect wiring to LMEP connections on logic board. Sensing Edge TEST SYSTEM 1. Reapply power to the operator. Green LED on CPS-EI should light if properly attached and sensing edge is not activated. 2. Partially open door. 3. Activate sensing edge, green LED on CPS-EI should go out. 4. Close door. NOTE: Green LED will go out if sensing edge is activated when door is fully closed. 5. Open door. 6. Begin closing. Activate sensing edge as door is closing. Door should stop and reverse to the open position. If any step fails, check connections. CPS-EI Coil Cord Electrical Junction Box 1 4-Wire Sensing Edge TROUBLESHOOTING TABLE PROBLEM SOLUTION CAUSE Green LED does not light. • Check that connections to CPS-EI are correct. • Check that sensing edge is not shorted (open door if closed). • All 6 connections are necessary for the LED to light. Green LED is lit but door does not reverse. • Check connections to operator. Door will only operate in C2 (constant pressure to close) mode even though CPS-EI seems to be installed correctly. • Check operator programming instructions for setting to B2 (momentary pressure to close) mode. • Operator was programmed for C2 (constant pressure to close) operation only. CPS-EI WIRING DIAGRAMS MEDIUM DUTY LOGIC OPERATOR NOTE: The operator will automatically convert to B2 wiring type. See owner's manual. Medium Duty Logic Board Green LED TTC 4-Wire Sensing Edge E1 STOP STOP 5 E4 40-34141-1 CLOSE OPEN CLOSE 6 OPEN 7 LOGIC 4 OPERATOR NOTE: Adjust the selector dial to the desired wiring type. See owner's manual. Logic 4 Board SBC COMMON STOP CLOSE Green LED 4-Wire Sensing Edge OPEN Black CPS-EI EDGE E1 E2 White E3 LMEP Black LMEP2 LMEP1 MAS White E4 COMMON 40-34141-1 TIMER DEFEAT FIRE DOOR OPERATORS (MODELS FDC, FDCL, FDOA, AND FDOB) Green LED 15 LMEP1 14 E3 13 LMEP2 16 17 E4 5 40-34141-1 4 White 18 6 19 7 2 01-34250C © 2010, The Chamberlain Group, Inc. All Rights Reserved J12 E2 3 White J9 Black 2 CPS-EI E1 1 Black LMPLC Board J8 4-Wire Sensing Edge C18 LMEP1 COM 4 White LEARN E3 LMEP2 D14 E2 White DIAGNOSTIC Black R27 LMEP1 LMEP2 INTRLK 1 2 3 CPS-EI Black
© Copyright 2024