1 IVG-8000 Series of Intelligent Video Gateways Quick Setup Guide 1. INTRODUCTION SETTING AN INITIAL IP ADDRESS 3. Harmonic would like to thank you for your investment in the 1. Power up the IVG-8000 unit. Once boot process is IVG-8000 Series of Intelligent Video Gateways. complete (after 2-3 minutes), a 'Status OK' screen is This document provides step-by-step instructions for quick displayed on the front panel. initial setup of the IVG-8000 unit using the IVG Element Management Software (EMS). Status OK For detailed information about operation and configuration of the IVG-8000 Series, refer to the IVG-8000 Series of Intelligent Video Gateways Installation Guide (Harmonic Click Enter for menu 2. Manual p/n 101504/Rev 1.0). 2. INSTALLATION AND CABLE CONNECTION 2. information about mounting, installation, safety according to the application requirements and following guidelines: 1. Input video streams (network programs) should be fed through GbE port or the ASI inputs. 2. Output streams are transmitted over GbE, ASI or QAM outputs. 4. menu is The port configuration menu is displayed. 1 2 3 CABLE CONNECTIONS IVG-8000 The Root EMS Station is connected. 3. in the IVG-8000 User Manual. the the keypad. Go to Root Configuration IP Addresses. Select the precautions and electrical information refer to Chapter 3 Connect on relevant Fast Ethernet port (1 to 3), through which the MECHANICAL AND ELECTRICAL INSTALLATION For Click [Enter] displayed. The EMS Station should be connected through any of the 4. Fast Ethernet 1 1 IP Address 127.000.000.002 127.000.000.002 Subnet mask 255.255.255.000 Broadcast Address 000.000.000.001 Set the IP Address and the Subnet Mask for the port. Verify that it matches the subnet of the EMS Station. 5. In case a router is used for the connection, configure the Default Gateway option too. 6. Go to Root Actions & Procedures and select the SAVE option to save the current configuration. CAUTION Fast Ethernet ports. Minimum platform requirements for the EMS Station: • P4 or equivalent processor @2GHz or higher • 1GB of RAM (2GB highly recommended) • Operating system - WindowsXP TURNING OFF OR RESETTING THE IVG-8000 WILL NOT AUTOMATICALLY SAVE THE CURRENT CONFIGURATION OF THE UNIT. WITHOUT SAVING THE CURRENT CONFIGURATION, ALL CHANGES WILL BE LOST WHEN TURNING OFF OR RESETTING THE IVG-8000. 2 4. INSTALLING THE EMS APPLICATION 5. CONNECTING TO THE IVG-8000 The EMS Application provides the GUI to manage the IVG- Run the EMS Application. The main application window is 8000 unit. It is stored on the IVG-8000 for easy installation displayed, in grey. Click the Device List pane, displayed on using a web browser. the left side bar of the window. To install the EMS Application, perform the following: 1. Open a web browser and enter the IVG-8000 IP address. ADDING A NEW IVG-8000 TO THE EMS The EMS Application can control several IVG-8000 units. The IVG Home Page is displayed. Before connecting to an IVG, the device must be added to the Device List pane. NOTE This is a one-time operation – the EMS device list is stored on the EMS. 1. From the Menu Bar, go to File Add IVG. Check correct Java version for the IVG-EMS: NOTE The EMS application is a Java language program which requires Java Runtime Environment version 5.0 (Update 16). The EMS will NOT install on any other Java version. 2. Run "cmd" in windows and type "java-version" to check the current Java version on your station. NOTE If you have any other version than version 5.0/Update 16 (lower or even higher version) install the correct version. 3. To install the Java Runtime Environment Version 5.0/update 16, click the Java SE Runtime Environment 5.0u16* link at the bottom of the IVG Home Page and follow the instructions of the installation wizard. NOTE An IVG can also be added from the Device List pane, by clicking the ‘Add IVG’ button in the Device List toolbar. 2. Fill in the device's name and IP address. Verify that Connect on Startup checkbox is marked. Click Finish. NOTE Install EMS Application: 4. 5. 6. Click Install EMS Application link at the bottom of the Checking the Connect on start-up checkbox will make the IVG Home Page. A file-download pop-up window is EMS attempt connection to the device upon launch. displayed. If the user does not check this box, connection must be In the File Download pop-up window, click Run. A performed manually. security warning may appear, depending on the browser For manual connection to the unit, select in the menu bar security properties. Click Run to continue. FileOpen and click the relevant unit. Follow the instructions of the setup wizard. Once setup is complete, the EMS Application is installed. A The unit is now added in the Device List pane. The EMS shortcut-icon is added to the desktop and to the automatically connects to the unit, the Stream management start menu. window is displayed and the unit is ready for configuration. 3 6. BASIC UNIT SETUP 7. STREAM MANAGEMENT WINDOW Basic unit setup is performed through the System window. When monitoring or setting the stream elements of the IVG Click the System button ( (ports, service, PIDs, and so on), the user should use the ) from the EMS toolbar to access the System window. Stream Management window. IP ADDRESSES CONFIGURATION INPUT AND OUTPUT STREAM MANAGEMENT IP addresses can be assigned to any of the IVG Ethernet The Stream Management window displays a hierarchy-map of ports – the four control ports and the GbE streaming port. the input and output ports, streams, programs, elementary- 1. select streams, and PIDs that are currently present in the IVG-8000 the unit. The window is divided into two sections: inputs (left, From the System window's left-pane Network Network Configuration tabs, and press blue icons) and outputs (right, orange icons). [Settings] button. 2. In the Network Configuration Panel, select the required GbE port line and press the [Configure] button. 3. In the GbE Port Configuration panel, set the IP information of the GbE port and press the [Set] button. Set other Ethernet configurations as required. 4. Close all panels. NOTE If there is a transport-stream present at one of the ASI inputs, the window will display the input TS elements. A bitrate chart can be viewed by right-clicking the port and selecting Bit Rate Chart. ELEMENT PROPERTIES MANAGEMENT Almost each element in the Stream Management window has a Properties table. The properties table allows the user to view and configure the element's parameters. Display the table by marking the element and clicking the properties icon ( NOTE Click the Save button ( recent changes. ) from the top toolbar to save all ) from the EMS toolbar. 4 8. 2. CREATING GBE CHANNELS Enter the information needed for setting the parameters of the Output GbE port for the output transport stream. GbE channels are multiplexes that are streamed into and out 3. Click Create. A new Output GbE channel is added in the Stream Management view. of the IVG over the GbE port. Both input and output GbE channels need to be set by the user. If a transport stream is present on the specified GbE channel, 9. PROGRAM CROSS-CONNECTION the stream information will display the input TS elements. A A cross-connection is an operation performed on an input bit-rate chart can be viewed by right-clicking the GbE stream, in order to route it to an output of the IVG, while channel and selecting Bit Rate Chart. performing different processing-functions on the program. CREATING INPUT GBE CHANNELS CREATING A PROGRAM CROSS-CONNECTION 1. 1. Click the Add GbE In button from the top toolbar. The Add Input GbE Channel Parameters window is displayed. From the Stream Management view, select the input program ( ) for the cross-connection and drag it to the requested output (ASI, QAM or GbE channel). 2. Drop the program only when the relevant destinationport is highlighted. The EMS will automatically launch the XConnect pane. NOTE The different sections of the pane will already be configured with the basic information of the source input program. 3. The Cross-Connection pane is displayed with the Program Properties section open. 2. Enter the information needed for setting the parameters of the Input GbE port for the input stream. 3. Click Create. A new Input GbE channel is added in the Stream Management view. CREATING OUTPUT GBE CHANNELS 1. Click the Add GbE Out button from the top toolbar. The Add Output GbE Channel Parameters window is displayed. 4. Enter the Program basic properties: Program Number, PMT PID and Program Alias. 5. Enter the optional parameters in the Program Properties section and the other sections in the Create XConnect window. These parameters are specific to the cross connection required. 5 6. Click Create Xconnect. If the connection is valid and successful, a 'Success' message and a green bar will be displayed at the bottom of the pane. 7. The new program will appear in the Stream Management view marked as 8. under the relevant output port. Close the Xconnect pane or drag-and-drop another program if another cross connection is required. Repeat steps 1-7 until all cross connects are created. 10. MONITORING THE UNIT After all cross connects have been established, the unit 11. REFERENCES For detailed information on IVG-8000 configuration and operation, refer to the IVG-8000 Series of Intelligent Video Gateways User manual. The following table details the location of specific setup instructions throughout the IVG8000 Series User Manual. QUICK GUIDE INSTRUCTIONS MANUAL REF. 2. Cable Connections 3.5 3. IP Address Setup 4.3 4. EMS Installation 3.6 should be operating with all output transport streams 5. Adding a New IVG-8000 5.2.2 available. 6. IP Address Configuration 5.6.1 Monitor the unit operation using the following means: 7. Input/Output Stream Management 5.4 1. Verify the output-stream structure through the Stream 7. Element Properties Management 5.5 Management view. 8. Creating Input GbE Channels 5.7 Monitor the bit-rate through the Bit-Rate Chart. To view 8. Creating Output GbE Channels 5.8 the chart, right-click a port and select Bit-Rate chart. 9. Creating Program Cross-Connection 5.9 2. 3. Monitor the IVG-8000 Event log. To view the event log, in the menu bar go to Window Events Window. 4. Monitor the IVG-8000 Alarms. To view the alarms currently present on the unit, from the menu bar go to Window Alarms. Harmonic Inc. 549 Baltic Way, Sunnyvale, CA94089, U.S.A Tel: +1 408 542-2500, Fax: +1 408 542-6708 Harmonic Documents p/n 101438 / Rev 1.0 IVG-8000 / SW 3.2
© Copyright 2024