COOPER LIGHTING - METALUX

COOPER LIGHTING - METALUX
®
DESCRIPTION
The AccordTM redefines fluorescent lighting by improving on aesthetics,
comfort and energy savings. The Accord provides the right amount
of light while eliminating surface shadows commonly found in
parabolics. Therefore, Accord increases the comfort level while
providing significant energy savings.
Type
Catalog #
Project
Date
Comments
The Accord is the ideal solution for offices, schools, hospitals, retail
and other applications.
Prepared by
SPECIFICATION FEATURES
Finish
Air Return
Shallow 3-1/4" deep housing is die
formed of code gauge, prime cold
rolled steel. Heavy gauge end plates
are securely attached with screws for
strength and rigidity and the elimination of gaps. Four auxiliary fixture
end suspension points are provided.
KOs for continuous row wiring.
Large access plate for supply connection.
Durable cold rolled steel with
multistage, iron phosphate pretreatment and white enamel finish to ensure maximum bonding and rust inhibition.
Optional Air Return model provides air flow through air slots in
the housing.
Electrical*
Shielding
Ballasts are Class “P” and are positively secured. Rotor-lock lampholders ensure positive lamp retention.
UL/CUL listed. Suitable for damp
locations.
Positively retained frosted
acrylic profile lenses provide a
soft but effective distribution of
light.
Construction
Reflectors
Reflector has high reflectance
baked matte white enamel
finish for luminous uniformity.
Controls
Fifth Light ballast options are
offered for both 0-10V continuous
dimming and DALI applications.
Combine with energysaving products like occupancy sensors, daylighting controls, and lighting
relay panels from Cooper Controls
(www.coopercontrol.com) to
maximize energy savings.
2AC
214T5
224T5
T5 LAMPS
Ballast Access
2' x 2' Recessed
Tr o f f e r S e r i e s
Ballast can be removed from below
without tools.
3-1/4"
[83mm]
23-3/4"
[603mm]
LAMP CONFIGURATIONS
MOUNTING DATA
11-3/4" [298mm]
Access Plate
ENERGY DATA
3-1/4"
[83mm]
Input Watts:
23-3/4" [603mm]
EB Ballast & STD Lamps @ 277V
214T5 (30)
224T5 (52)
1-1/2"
[39mm]
23-3/4"
[603mm]
Luminaire Efficacy Rating
LER =FL77 LPW
Catalog Number: 2AC-214T5
3-3/8"
[86mm]
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $2.65
3-1/16"
[78mm]
24" [610mm]
*Reference the lamp/ballast data in the
Technical Section for specific lamp/ballast
requirements.
NOTE: 2' x 2' and 2' x 4' allow for row mounting
(1' x 4' does not support feature)
**Consult Pre Sales Technical Support.
***See Drywall Frame Kit Accessory
CEILING COMPATIBILITY
G
Grid/Lay-in
Standard
COOPER LIGHTING
F
Drywall Frame
Kit
Ceiling
Type**
Trim
Type
Exposed Grid
Concealed T
Slot Grid
Flange
G
G or T
G or T
***
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO
LOCAL, STATE OR FEDERAL LAWS
Safe and convenient means of
disconnecting power.
ADF051721
2AC
PHOTOMETRICS
2AC-214T5
Electronic Ballast
(2) F14T5/835 lamps
1350 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency 89.4%
Test Report:
2AC-214T5.IES
LER = FL-77 LPW
Yearly Cost of 1000
lumens, 3000 hrs
at .08 KWH = $2.65
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
755
752
741
723
698
667
630
587
539
487
432
374
314
253
191
131
76
31
0
106
93
80
70
62
55
49
44
40
37
34
106 106
89 85
74 68
62 56
53 47
46 40
41 35
36 31
33 27
29 24
27 22
104
94
85
77
71
65
60
55
51
48
45
104
90
78
68
60
54
48
44
40
36
34
104
87
73
61
53
46
40
36
32
29
27
104
84
68
56
47
40
35
31
27
24
22
20%
50%
50 30 10
30%
50 30 10
10%
50 30 10
0%
0
99
87
75
66
58
52
47
42
39
35
33
95
83
72
63
56
50
45
41
37
34
32
91
80
69
61
54
48
44
40
36
34
31
89
74
61
51
43
37
32
28
25
22
20
99
84
70
60
51
45
40
35
32
29
26
99
81
66
55
46
40
34
30
27
24
22
95
81
68
58
50
44
39
35
31
28
26
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
601
1001
1851
2414
2414
%Lamp
22.3
37.1
68.6
89.4
89.4
||
Candela
Angle
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
Along II
930
927
914
892
861
822
776
723
664
600
532
461
387
311
235
160
92
37
0
Across ⊥
930
931
927
919
908
890
868
841
808
769
723
670
598
480
337
215
118
43
0
45°
930
928
920
906
886
860
828
790
747
697
642
581
514
441
347
233
129
45
0
Coefficients of Utilization
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
106
97
88
80
73
67
61
57
53
49
46
⊥
Across ⊥
755
755
752
746
736
722
704
682
656
624
587
544
486
389
274
175
97
35
0
45°
755
753
747
736
719
698
671
641
606
566
521
471
417
358
281
189
105
37
0
Coefficients of Utilization
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
2AC-224T5
Electronic Ballast
(2) F24T5HO/835
lamps
1750 lumens
Spacing criterion:
(II) 1.2 x mounting
height, (⊥) 1.4 x
mounting height
Efficiency 85%
Test Report:
2AC-224T5.IES
LER = FL-93 LPW
Yearly Cost of 1000
lumens, 3000 hrs
at .08 KWH = $2.58
Candela
%Fixture
24.9
41.4
76.7
100.0
100.0
Average
0-Deg
cd/sm
1872
1772
1627
1376
967
95
78
64
54
46
39
34
30
27
24
22
Average
45-Deg
cd/sm
2176
2232
2303
1985
1154
91
78
66
57
49
43
38
34
31
28
26
91
76
63
53
45
39
34
30
27
24
22
Average
90-Deg
cd/sm
2399
2578
2502
1838
1092
rc
rw
RCR
0
1
2
3
4
5
6
7
8
9
10
Effective floor cavity reflectance
80%
70%
70 50 30 10
70 50 30 10
101
92
83
76
69
63
58
54
50
47
44
101
88
76
66
59
52
47
42
38
35
32
101
84
70
59
51
44
39
35
31
28
26
101
81
65
53
45
38
33
29
26
23
21
99
90
81
74
67
61
57
52
49
46
43
99
86
74
65
57
51
46
41
38
35
32
99
82
69
58
50
44
38
34
31
28
25
99
79
64
53
45
38
33
29
26
23
21
20%
50%
50 30 10
30%
50 30 10
50
94
82
71
62
55
49
44
40
37
34
31
90
79
69
60
53
48
43
39
36
33
30
87
76
66
58
51
46
41
38
35
32
29
94
79
67
57
49
43
38
34
30
27
25
94
77
63
52
44
38
33
29
26
23
21
90
77
65
55
48
42
37
33
30
27
25
Zonal Lumen Summary
Luminance Data
Zone
0-30
0-40
0-60
0-90
0-180
Angle
in Deg
45
55
65
75
85
Lumens
740
1232
2279
2973
2973
%Lamp
21.1
35.2
65.1
85.0
85.0
%Fixture
24.9
41.5
76.7
100.0
100.0
90
74
61
51
43
37
32
29
25
23
21
Average
0-Deg
cd/sm
2305
2184
1999
1679
1153
Average
45-Deg
cd/sm
2678
2752
2835
2446
1403
10%
30 10
87
74
63
54
47
41
36
32
29
27
24
87
72
60
50
43
37
32
28
25
23
21
0%
0
85
70
58
48
41
35
30
27
24
21
19
Average
90-Deg
cd/sm
2955
3173
3086
2257
1340
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
4/13
ADF051721
2AC
ORDERING INFORMATION
SAMPLE NUMBER: 2AC-214T5-UNV-EBT1NDIM
Rating
Blank=
Standard
NY=New York
Rated
ATW-SW4=
Chicago
Rated
Width
2=2' Width
Series
AC=Accord Series
Type
A=Air (optional)
Number of Lamps
(Not included)
2=2 Lamp
Wattage (Length)
14T5=14W T5 (24")
24T5=24W T5HO (24")
Shielding
Blank=Frosted Acrylic
(standard)
SQP=Lens with Square
Pattern Insert
RDP=Lens with Round
Pattern Insert
Voltage (1)
UNV=Universal Voltage
120-277
Options
GL=Single Element Fuse
GM=Double Element Fuse
Flex=Flex installed
EL=Emergency Installed
Lamps
L5835=T5 Lamp, 3500K
L5841=T5 Lamp, 4100K
L5835HL=T5 Lamp, 28W, 3500K, 2900 Lumens
L5841HL=T5 Lamp, 28W, 4100K, 2900 Lumens
(1)
(2)
NOTES: Products also available in non-US voltages and frequencies for international markets. Step dimming ballast available
(3)
(4)
for 14W T5 lamps only. .90 and 1.15 ballast factor available for 2 or 3 14W T5 lamps only. Step dimming ballast available for 2 or
(5)
3 lamp 14WT5 lamps only. 1 lamp step dimming ballast in a normal ballast factor not available. 2 lamp ballast will not operate 1
(6)
(7)
lamp. 1 lamp ballast in a high ballast factor not available. For a complete listing of Fifthlight Technology products and other solu(8)
tions from Cooper Controls, visit www.coopercontrol.com.
0-10V ballast do not include DALI feature. Please select DALI ballast for
(9)
use with Fifth Light system.
Specification grade 0-10V dimming ballast are NEMA premium and CEE listed. They are compatible
(10)
with low mercury and energy saving lamps.
Standard 0-10V ballast not available for 24W T5HO lamps.
(11)
Specification Grade 0-10V ballast not available for 24W T5HO lamps.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change
without notice. Consult your Cooper Lighting Representative for availability and ordering information.
Ballast Type (1)
EBT =T5/T5HO Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Standard Ballast Factor=1.0
Packaging
U=Unit Pack
PALC=Job
Pack, in carton
Ballast/FactorType
EBT N=T5/T5HO Electronic Program Rapid Start.
Total Harmonic Distortion < 10%.
Normal Ballast Factor=.90 (3)
EBT H=T5/T5HO Electronic Program Rapid Start.
Total Harmonic Distortion< 10%.
High Ballast Factor=1.15 (3), (6)
EBT NDIM=T5/T5HO Electronic Program Rapid
Start. Total Harmonic Distortion < 10%.
Step Dimming, Normal
Ballast Factor=.95-1.0 (4), (5)
EBT HDIM=T5/T5HO Electronic Program Rapid
Start. Total Harmonic Distortion < 10%.
Step Dimming, High Ballast
Factor=1.15 (4)
0-10V Dimming Ballasts (8)
5LTV5 =T5 0-10V Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
5LTVS5 =T5 0-10V Spec Grade Program Rapid
Start. Total Harmonic Distortion < 10%.
Ballast Factor 1.0 (9)
5LTV5H =T5HO 0-10V Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0 (10)
5LTVS5H =T5HO 0-10V Spec Grade Program Rapid
Start. Total Harmonic Distortion < 10%.
Ballast Factor 1.0 (9), (11)
Fifth Light DALI Ballasts (7)
5LT5 =T5 DALI Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
5LT5H =T5HO DALI Program Rapid Start.
Total Harmonic Distortion < 10%.
Ballast Factor 1.0
Number of Ballasts
1=1 Ballast
2=2 Ballasts
ACCESSORIES
T3A END E.Q. BRACKET PARTS BAG
SHIPPING INFORMATION
Catalog No.
Wt.
2AC-214T5
2AC-224T5
28 lbs.
28 lbs.
Visit our web site at www.cooperlighting.com
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801
4/13
ADF051721