DCV 10 Stainless Steel Disc Check Valve for use with Automatic Pump Traps Description The DCV10 disc check valve has been designed specifically for use with Spirax Sarco's APT14HC and APT14SHC automatic pump-traps. The check valve ensures the correct flow of condensate and other suitable fluids through these condensate pumps and also prevents reverse flow. Sizes and pipe connections The PN25 design is available in sizes DN25, DN40, DN50 and DN80 to fit between EN 1092 PN16 and JIS / KS 10K flanges. Please note: The Class 300 design is available in size DN40 only to fit between ASME B 16.5 (ANSI) Class 150 and Class 300 flanges. Standards - Designed in accordance with BS EN 14341:2006. This product fully complies with the requirements of the European Pressure Equipment Directive 97/23/EC. Shut-off - Shut-off conforms to EN 12266-1:2003 Rate F. Certification - This product is available with certification to EN 10204 3.1. Note: All certification/inspection requirements must be stated at the time of order placement. 1 2 Pressure/temperature limits PN25 Steam saturation curve 212 122 32 14 C 0 73 Class 300 Temperature °F 392 290 Pressure bar g 122 B 290 435 580 719 Pressure psig The product must not be used in this region. A - B For fitting between Class 150 and Class 300 flanges. A - C For fitting between EN 1092 PN16 and JIS/KS 10K flanges. Pipeline Auxiliaries 0 3 Materials Steam saturation curve 212 5 363 A 302 32 14 145 218 Pressure psig Temperature °C A 302 145 Body design condition PN25 or Class 300 Maximum allowable PN25 363 psig @ 32°F PMA pressure Class 300 719 psig @ 32°F Maximum allowablePN25392°F @ 250 psig TMA temperature Class 300 392°F @ 500 psig Minimum allowable temperature -10°C Maximum operating PN25 363 psig @ 32°F PMO pressure Class 300 718 psig @ 32°F Maximum operatingPN25392°F @ 250 psig TMO temperature Class 300 392°F @ 500 psig Temperature limits 14°F to 392°F Minimum operating temperature 14°F PN25 544 psig Designed for a maximum cold hydraulic test pressure of: Class 300 1079 psig Temperature °C Temperature °F 392 4 Pressure bar g No.Part Material PN Austenitic stainless steel 1.4308 1Body ANSI Austenitic stainless steel A351 CF8 DN25 A276 316L DN40 Austenitic stainless steel 2Disc DN50 Austenitic stainless steel AISI 316L DN80 3 Spider Martensitic stainless steel BS 3146-2 ANC2 BS 2056 316 4 Springs Stainless steel S42 5 'O' ring Fluorocarbon polymer FEPM (TFEP) Kv values Size DN25DN40DN50DN80 Kv 10.8264380 For conversion: Cv (UK) = Kv x 0.963 Cv (US) = Kv x 1.156 Opening pressures in psi (mbar) Differential pressures with zero flow. Flow direction DNDN25DN40DN50 DN80 0.36 (25) 0.41 (28) 0.42 (29) 0.45 (31) 0.33 (22.5) 0.36 (24.5) 0.36 (24.5) 0.37 (25.5) 0.29 (20) 0.29 (20) 0.29 (20) 0.29 (20) Local regulation may restrict the use of this product below the conditions quoted. Limiting conditions refer to standard connections only. In the interests of development and improvement of the product, we reserve the right to change the specification. TI-P601-32-US 4.14 8:532 Operation The DCV10 is opened by the pressure and flow of condensate and is closed by the pressure of the spring when flow ceases and before reverse flow occurs. Open Closed Dimensions / weights (approximate) in inches and lb. Size A B C D E FWeight Open Closed 1" 2.8 2.80.9 1.20.91.01.30.9 1½" 3.6 3.41.2 1.71.31.61.91.8 2" 4.2 4.01.6 2.21.72.02.43.0 3" 5.6 5.22.0 2.72.13.13.55.6 ANSI 150 and ANSI 300 Size A B C D E FWeight Open Closed 1½"3.73.41.81.91.81.61.91.8 Pressure loss diagram Pressure loss in bar D C 440 308 3" 132 88 2" 44 31 22 Water flowrate Vw m3 /h Water flowrate Vw GPM 220 1½" 1" 13 0.8 4.4 3.1 2.2 0.15 0.30 0.73 1.5 2.9 Pressure loss in psi 7.3 B F 14.5 Pressure loss diagram with open valve at 68°F (20°C). The values indicated are applicable with to spring loaded valves with horizontal flow. With vertical flow, insignificant deviations occur only within the range of partial opening. The curves given in the chart are valid for water at 68°F (20°C). To determine the pressure drop for other fluids, the equivalent water volume flowrate must be calculated and used in the graph. ______ Vw = √ S.G x V E A Vw = Equivalent water volume flow in GPM S.G. = Specific Gravity V = Volume of fluid GPM Pressure loss information for steam, compressed air and gases is available from Spirax Sarco. Safety information, installation and maintenance How to order Example: 1 Spirax Sarco 1" DCV10 stainless steel check valve to fit between ANSI 150 flanges for use with an APT 14 HC pump. TI-P601-32-US Spirax Sarco, Inc., 1150 Northpoint Blvd., Blythewood, SC 29016 Telephone: (803) 714-2000 FAX (803) 714-2222 © Spirax Sarco, Inc. 2014 Pipeline Auxiliaries For full details see the Installation and Maintenance Instructions (IM-P601-33) supplied with the product. Installation note: The DCV10 must be installed close coupled to the pump. It can be fitted in either a horizontal or vertical line in accordance with the direction of flow arrow on the body. Note: Flanges, bolts (or studs), nuts and gaskets to be supplied by the installer. 4.14 8:533
© Copyright 2024