BOLDPLAY WALL LED DIRECT/INDIRECT ASYMMETRIC, MESOOPTICS LENS CRI >80 3000K, 3400 lm/4ft

BOLDPLAY
WALL LED
DIRECT/INDIRECT ASYMMETRIC, MESOOPTICS LENS
CRI >80 3000K, 3400 lm/4ft
Project:
Spec Type:
Catalog No: 7808LCEQN
Qty
Line Notes:
Ordering guide
Product Type
Source
Color Temp *
Lumens *
Lower Optics
Upper Optics
7808
L
C
E
Q
N
BoldPlay Wall
Direct/Ind
L
LED
A
B
C
4000K
3500K
3000K
E 3400 lm/4ft
G 2300 lm/4ft
Q MesoOptics Lens
N None
Run Length
04
08
4'
8'
Wiring †
1
3
7
8
B
1 cct
1
1 cct w/ EM cct
2
1 cct w/ Dimming
1 cct w/ TW
2 cct A/B
Voltage ‡
120V
277V
Driver ‡
E Standard
Finish
W
T
B
C
White
Titanum Silver
Black
Custom Color
* Nominal values within a range. Consult ies file for exact color temp and lumens † Consult website for complete list of standard wiring options
Mounting Hardware
Wall
Endcaps -
Mount Type
Consult separate mounting spec sheet for mount type options
.
Integrated Controls Please indicate with check mark.
No Options Available
© 2014 Koninklijke Philips N.V. All rights reserved.
Specifications are subject to change without notice.
www.philips.com/luminaires
7808LCEQN.pdf 10.14 page 1 of 3
BOLDPLAY
WALL LED
DIRECT/INDIRECT ASYMMETRIC, MESOOPTICS LENS
Photometry
180
135
135
90
90
1200 cd
Values per 4ft unit
Total Output
3232 lm
Efficacy
77.9 lm/W
CCT
3046K
CRI
81
R9
17
Distribution
58% Up / 42% Down
Spacing Criteria (0/90/180°)
1.58/1.32/0.75
Fixture photometry has been
conducted by an NVLAP accredited
testing laboratory in accordance with
IESNA LM-79:2008
Lumen maintenance of the LEDs has
been tested by the manufacturer in
accordance with IESNA LM-80:2008
IES files for this and other
photometric options can be
downloaded online at
www.lightingproducts.philips.com
Meets RP-1-04 recommendations for VDT-Intensive spaces
45
45
0
90-90
45-135
0-180
58% Up / 42% Down
Candela Distribution
Vertical
Angle
0
5
15
25
35
45
55
65
75
85
90
95
105
115
125
135
145
155
165
175
180
Horizontal Angle
0
45
90 135
541 541 541 541
633 606 545 490
791 709 539 416
857 760 517 345
658 635 453 271
394 403 334 206
246 243 220 159
140 132 126 108
53
53
51
50
9
10
9
13
0
0
0
2
14
37
30
13
937 698 115 68
1039 608 185 114
776 564 230 152
611 525 261 181
507 485 299 221
435 435 327 261
382 382 334 293
334 333 320 311
317 317 317 317
Coefficients of Utilization (%)
180
541
466
374
294
228
176
146
105
52
16
4
13
64
104
132
159
195
234
273
305
317
Zonal
Lumens
0
52
159
252
280
240
183
121
56
14
0
79
347
371
318
263
214
157
95
31
0
Electrical Specifications
Input Voltage
120V
Input Power
41.5W
Input Current
0.362A
Power Factor
0.956
Tested values – contact technical support
for rated values. Off-state power zero
unless certain controls are specified.
© 2014 Koninklijke Philips N.V. All rights reserved.
Specifications are subject to change without notice.
www.philips.com/luminaires
7808LCEQN.pdf 10.14 page 2 of 3
RCR
0
1
2
3
4
5
6
7
8
9
10
Ceiling:
Wall:
70
105
96
88
81
74
68
63
58
54
50
47
50
105
92
81
72
64
57
51
46
42
38
35
80
30
105
89
75
65
56
49
43
38
34
31
28
10
105
85
70
59
50
43
38
33
29
26
23
Avg. Luminance (cd/m2)
Vertical
Angle
55
65
75
85
Horizontal Angle
0
90
180
5366
4953
3185
4078
3846
3058
2433
2536
2387
1050
1315
1867
70
96
88
80
73
67
62
57
53
49
46
43
70
50
96
85
74
66
59
52
47
43
39
35
33
30
96
81
69
60
52
46
40
36
32
29
26
50
79
70
62
55
49
44
40
36
33
30
28
50
30
79
68
58
50
44
39
34
31
28
25
23
10
79
66
55
47
40
35
30
27
24
21
19
0
0
42
36
31
27
23
21
18
16
15
13
12
BOLDPLAY
WALL LED
DIRECT/INDIRECT ASYMMETRIC, MESOOPTICS LENS
Options and Details
Optics & Styles
Housing
Mounting
Precision formed 18 gauge cold-rolled steel.
Suspended: Tamper-resistant aircraft cable gripper provides infinite
vertical adjustment capability. Aircraft cable, crimp and cable gripper
are independently tested to meet stringent safety requirements.
Wall: Fixture is mounted flush to wall using hidden wall brackets.
Brackets attach to existing structure, variable within 2”-5” of end or
joint.
Weight
Maximum: Suspended 3.75lb/ft & Wall 3.0lb/ft
Optical System
The optical system is comprised of arrays of LEDs, edge-lighting a
low profile Light Guide panel. The Light Guide panel allows light to
be coupled and transmitted through total internal reflection. The
microstructured surface of the panel optimizes the light extraction to
create a direct indirect distribution. Light is purified and controlled by
MesoOptics film as it passes through the nonglare acrylic lens.
Standard distribution is 70% up/30% down for suspended mount
version, and 60% up/40% down for wall mount version.
Standard Driver
Dimming: 0-10V - 5-100%. Output is Class 2 rated.
Lumen Maintenance
At an ambient temperature of 25°C, the LED lumen maintenance
expectation is L80 (12k) 60,000 hrs.
Joints
Self-aligning joining system with hands-free pre-joining wire access.
Endcaps
Diecast aluminum endcaps; Suspended: available in sculpted
(standard) or flat (optional). Three flat versions: gloss balck, gloss
white & solid flat are available.
Wall: Three flat versions: gloss black, gloss white & solid flat are
available.
Electrical
Factory pre-wired to section ends with quick-wire connectors.
Approvals
Certified to UL, CSA and IES standards.
Finish
Standard finish is textured matte White, Black or Titanium Silver.
Environment
Rated for dry or damp locations in operating ambient temperatures
0-40°C (32-104°F). Certain luminaire components may be
adversely affected by contaminants. Damage caused by sulfur,
chlorine, petroleum based solutions or other contaminants are not
covered under warranty.
Due to continuing product improvements, Philips Ledalite reserves the right to change the specifications without notice.
©2014 Koninklijke Philips N.V. All rights reserved.
Specifications are subject to change without notice.
www.philips.com/luminaires
7808LCEQN.pdf 10.14 page 3 of 3
Philips Lighting
North America Corporation
200 Franklin Square Drive
Somerset, NJ 08873
Phone: 855-486-2216
Philips Lighting Company
281 Hillmount Road
Markham ON, Canada L6C 2S3
Phone: 800-668-9008