System250_Pellet_Hydro_2WAYS2 For Pellet Thermo Stove Hydro MB250 CP120 CP110 2WAYS2 High Voltage Safety INPUTS: Total n. 02 • Water Boiler Safety Thermostat • Pellet Tank Thermostat • PressureSwitch • Auxiliary Safety Thermostat Control OUTPUTS: Total n. 08 • Auger Motor with RPM regulation • Auger Motor with ON/OFF regulation • Combustion Fan with RPM/Volt regulation RPM/Volt • Igniter • Stove Pump • DHW Electrovalve/Pump • Combustion Fan2 • Heating Fan for Hydro/Air version • Auger Safety: Blocco Coclea fuori Regolazione • Cleaning Brazier Motor • Cleaning Exchanger Motor • Pellet Safety Valve • External Pellet Loading Motor • Auxiliary Auger Motor • Air Combustion Valve STOP • Gas Boiler Integration SW FUNCTIONALITIES • Hydraulic Plan Configuration: Heating and DHW production • Remote Radio 2WAYS2 configured as room thermostat • RPM Auger Motor Management for Precise and Noiseless control of the Combustion • Auger Unblock System in case of Block • Auger Safety in case of Loss of Speed Control • Brazier/Exchanger Cleaning • Chrono Integrated • Summer/Winter Function • Funzione Estate/Inverno R FL O W LIMIT AI Low Voltage INPUTS: Total n. 11 • Exhaust/Combustion chamber Temperature Probe • Water Boiler Temperature Probe • Buffer/DHW Tank Temperature Probe • Ambient Temperature Probe • Primary Air Flow Sensor • Water Pressure Sensor • Flow Switch • External Chrono/Thermostat • Back Flame Thermostat • Limit Swith Cleaning Motor • Pellet Level Sensor • Encoder RPM Combustion Fan Speed • Encoder RPM Auger Motor Speed ITCH RP M V O LT V O LT SAFETY UNBLOCK RPM RPM TiEmme Elettronica Zona Ind.Le Torre Sapienza 06055 Marsciano (PG) ITALY RPM ON/OFF