System250_Pellet_Hydro_2WAYS2 For Pellet Thermo Stove Hydro MB250 CP110

System250_Pellet_Hydro_2WAYS2
For Pellet Thermo Stove Hydro
MB250
CP120
CP110
2WAYS2
High Voltage Safety INPUTS:
Total n. 02
• Water Boiler Safety Thermostat
• Pellet Tank Thermostat
• PressureSwitch
• Auxiliary Safety Thermostat
Control OUTPUTS:
Total n. 08
• Auger Motor with RPM regulation
• Auger Motor with ON/OFF
regulation
• Combustion Fan with RPM/Volt
regulation RPM/Volt
• Igniter
• Stove Pump
• DHW Electrovalve/Pump
• Combustion Fan2
• Heating Fan for Hydro/Air
version
• Auger Safety: Blocco Coclea
fuori Regolazione
• Cleaning Brazier Motor
• Cleaning Exchanger Motor
• Pellet Safety Valve
• External Pellet Loading Motor
• Auxiliary Auger Motor
• Air Combustion Valve STOP
• Gas Boiler Integration
SW
FUNCTIONALITIES
• Hydraulic Plan Configuration:
Heating and DHW production
• Remote Radio 2WAYS2
configured as room thermostat
• RPM Auger Motor Management
for Precise and Noiseless control
of the Combustion
• Auger Unblock System in case of
Block
• Auger Safety in case of Loss of
Speed Control
• Brazier/Exchanger Cleaning
• Chrono Integrated
• Summer/Winter Function
• Funzione Estate/Inverno
R FL O
W
LIMIT
AI
Low Voltage INPUTS:
Total n. 11
• Exhaust/Combustion chamber
Temperature Probe
• Water Boiler Temperature Probe
• Buffer/DHW Tank Temperature
Probe
• Ambient Temperature Probe
• Primary Air Flow Sensor
• Water Pressure Sensor
• Flow Switch
• External Chrono/Thermostat
• Back Flame Thermostat
• Limit Swith Cleaning Motor
• Pellet Level Sensor
• Encoder RPM Combustion Fan
Speed
• Encoder RPM Auger Motor
Speed
ITCH
RP M
V O LT
V O LT
SAFETY
UNBLOCK
RPM
RPM
TiEmme Elettronica Zona Ind.Le Torre Sapienza 06055 Marsciano (PG) ITALY
RPM
ON/OFF