TELLABS DATA SHEET Tellabs® 1000 Multiservice Access Platform (MSAP) LET Power Supply Unit (L-PSU) Plug-in Card Overview The Tellabs® 1000 Multiservice Access Platform (MSAP) LET Power Supply Unit (L-PSU) plug-in card converts the -48 V local exchange battery input into the ±5 V and -32 V required by the common control equipment and line cards in the Tellabs 1000 MSAP Local Exchange Terminal (LET). L-PSU FAIL ACTV FUSE The L-PSU uses a DC-to-DC switching converter for high efficiency and low thermal dissipation. Only one L-PSU is required to power each Tellabs 1000 MSAP LET shelf; however, a card slot is provided for a redundant L-PSU. The L-PSU features two GMT fuses for redundant source coordination. The first fuse protects the DC-DC converter, and the second fuse protects the -48 V DC output. Features and Benefits High-efficiency switching DC-DC converter n Reverse polarity protection n Overvoltage/overcurrent shutdown n Low-voltage alarm n Low thermal dissipation n LEDs on the faceplate of the IMA card indicate the following conditions: Green ACTV — the plug-in card is active n Red FAIL — the plug-in card has failed n Red FUSE — failed fuse on the plug-in card n The unit also provides alarm and status indications to the CPU. Test jacks on the front panel can be used to monitor the system voltages. Tellabs® 1000 Multiservice Access Platform (MSAP) LET Power Supply Unit (L-PSU) Plug-in Card See Tellabs.com for more information about Tellabs Solutions DATA SHEET TELLABS® 1000 MULTISERVICE ACCESS PLATFORM (MSAP) LET POWER SUPPLY UNIT (L-PSU) PLUG-IN CARD Specifications DC-DC Converter Output Current Input: -40 V DC to -56.5 V DC n Output: +5.15 V DC ± 1.5% n n n Dimensions +5 V DC, 15 A n -5 V DC, 2 A n Height: 5.125 in (13.018 cm) -32 V DC, 3 A n Width: 1.0 in (2.54 cm) – -5.15 V DC ± 10.0% n – -32.0 V DC ± 10% n -48 V DC, 2 A n – -39 V DC to -56.5 V DC n Total available output power: 150 W Compliance n Isolation n Output Regulation n Low-voltage disconnect: -38 V DC ± 5.15 V DC n < 1.5% load n Output ground: Referenced to positive battery input Environmental n Ripple and Noise ± 5 V DC n 1.0% peak-to-peak, n Conducted Noise: GR-1089-CORE n < 0.20% per specified temp range n Weight: 1.0 lb (0.45 kg) Internal converter: 500 V input to output < 1.5% line n Depth: 10.5 in (26.67 cm) Operating temperature: -40° F to +149° F (-40° C to +65° C) Relative humidity: 5%–95%, noncondensing n -32 V DC @ 100 mV peak-to-peak n Take the next step. Contact Tellabs today. +1 800 690 2324 +1 630 798 9900 www.tellabs.com 1415 West Diehl Road Naperville, IL 60563 U.S.A. TEL9473 11/14 © 2014, Tellabs Access, LLC. All rights reserved. See Tellabs.com for more information about Tellabs Solutions
© Copyright 2024