the erbe forceps range with its non-stick effect.

E l ectr o s u rger y
B i p o l a r PR E M I U M F o r c e p s
B i p o l a r I r r ig ati o n F o rc e p s
Th e ERBE F o rce p s R a n g e
w i t h i t s N o n -S t i ck E ffec t .
m
miu
Pre
NE W
m
miu
Pre
A dva n tag es
of the
N o n -S t i ck E ffec t.
During bipolar electrosurgical coagulation an unwanted sticking
effect can occur when the forceps’ tips adhere to the tissue. This
carries a risk of inadvertent tearing open of coagulated vessels. In
addition, tissue sticking to the forceps adversely affects the continued coagulation. Sticking is markedly reduced with the automatic power regulation provided by the ERBE VIO unit technology
and the use of Soft Coagulation with AUTO STOP. The new PREMIUM forceps and irrigation forceps additionally reduce sticking.
The forceps are available in addition to the standard models (s.
catalogue of electrosurgical accessories).
The ERBE bipolar forceps are available in various lengths and
shapes for different surgical and anatomical requirements.
Coagulation of blood vessels
Advantages
Minimal adhesion of tissue
Minimal tearing of coagulated tissue
Precise and safe operative procedure
Maximum saving of time due to minimal time
required for cleaning
Safe coagulation due to consistent
energy output
Superficial coagulation
Th e f o rce p s w i t h t h e coo l- d ow n effec t.
M i n i m i zes t i ssu e a d h es i o n to t h e b r a n ch es .
ium
Prem
m
miu
Pre
NE W
m
miu
Pre
m
miu
Pre
The reusable PREMIUM forceps make it easy to coagulate tissue. Sticking effects on the tips of the forceps are reduced to a minimum.
The trick lies in a special alloy with high temperature conductivity to
draw the heat away from the forcep tip and to prevent overheating.
Heat accumulation and the resulting adhesion of coagulate is significantly reduced. The abraded and matt-finished surface of the forceps’
Themography illustrates the low temperature level of the forceps’ tips during
coagulation
tips allows tissue and vessels to be grasped safely. At the same time
potential light reflections are reduced, improving the visibility at the
operating site when working under a microscope.
The new forceps are available in all popular shapes and sizes and can
be used in any surgical discipline.
Areas of application
All surgical disciplines
Special benefits in
Neurosurgery
ENT
Oral and maxillofacial surgery
Plastic surgery
The benefits at a glance
Limited tissue adhesion due to high temperature conductivity
Long instrument life due to high-quality alloy
Targeted precise coagulation due to precise design of the tips
Firm grasping of tissue due to abraded gripping surface
Less time required intraoperatively for cleaning
Good visibility at the operating site due to reduced light reflections (e.g.
during preparation under a microscope)
O v e rv i e w
of the
PREMIUM
f o rce p s .
m
miu
Pre
Pinpoint grasping with
innovative tip geometry
Bipolar forceps PREMIUM – STRAIGHT
Bipolar forceps PREMIUM – BAYONET
Order No.
Length
Tip
Order No.
Length
Tip
20195-501
12 cm
pointed 0.2 mm
20195-531
15.5 cm
pointed 0.2 mm
20195-502
12 cm
very fine 0.4 mm
20195-532
15.5 cm
very fine 0.4 mm
20195-503
12 cm
fine 0.7 mm
20195-533
15.5 cm
fine 0.7 mm
20195-504
12 cm
fine 0.7 mm; angled
20195-534
17 cm
pointed 0.2 mm
20195-505
18.5 cm
pointed 0.2 mm
20195-535
17 cm
blunt 1.0 mm
20195-506
18.5 cm
very fine 0.4 mm
20195-536
20 cm
very fine 0.4 mm
20195-507
18.5 cm
fine 0.7 mm
20195-537
20 cm
fine 0.7 mm
20195-508
18.5 cm
blunt 1.0 mm
20195-538
20 cm
blunt 1.0 mm
20195-509
18.5 cm
blunt 1.0 mm; angled
20195-539
20 cm
blunt 1.2 mm
20195-510
20 cm
pointed 0.2 mm
20195-540
20 cm
blunt 2.0 mm
20195-511
20 cm
very fine 0.4 mm
20195-541
20 cm
blunt 1.2 mm; angled downwards
20195-512
20 cm
blunt 1.0 mm
20195-542
20 cm
blunt 1.2 mm; angled upwards
20195-513
20 cm
blunt 1.0 mm; angled
20195-543
23 cm
pointed 0.2 mm
20195-514
20 cm
blunt 2.0 mm; angled
20195-544
23 cm
very fine 0.4 mm
20195-515
23 cm
blunt 2.0 mm
20195-545
23 cm
fine 0.7 mm
20195-516
26 cm
blunt 1.0 mm; angled
20195-546
23 cm
blunt 1.0 mm
20195-547
23 cm
blunt 1.2 mm
20195-548
23 cm
fine 0.7 mm; angled upwards
20195-549
23 cm
fine 1.2 mm; angled upwards
20195-550
23 cm
fine 0.7 mm; angled downwards
20195-551
25 cm
pointed 0.2 mm
20195-552
25 cm
very fine 0.4 mm
20195-553
25 cm
fine 0.7 mm
20195-554
25 cm
blunt 1.0 mm
20195-555
25 cm
blunt 1.2 mm
20195-556
25 cm
fine 0.7 mm; angled upwards
pointed
very fine
fine
blunt
O v e rv i e w
of
I r r i g at i o n F o rce p s
and
C o n n ec t i n g C a b l es .
Bipolar irrigation forceps – STRAIGHT
Bipolar irrigation forceps – BAYONET
Order No.
Length
Tip
Order No.
Length
Tip
20195-150
20 cm
blunt 1.5 mm
20195-151
20 cm
fine 0.5 mm
20195-152
20 cm
blunt 1.0 mm
20195-153
23 cm
fine 0.5 mm
20195-154
23 cm
blunt 1.0 mm
Connecting cable for bipolar forceps
for VIO, ICC, ACC
Length 4 m
No. 20196-045
Length 5 m
No. 20196-057
Connecting cable for bipolar forceps
for VIO, ICC, ACC, international
Length 4 m
No. 20196-053
Length 5 m
No. 20196-061
Connecting cable for bipolar forceps
for Valleylab
Length 4 m
No. 20196-055
fine
blunt
Th e F u n c t i o n
of the
B i p o l a r I r r i g at i o n F o rce p s .
The external diameter of the irrigation
connection is 3 mm. It can be connected to all convention gravity infusion
systems
The irrigation outlet is located
on one of the branch arms of the
forceps
The irrigation channel passes through the lower part of the forceps
ending in an outlet in one of the branch arms. Irrigation with an NaCl
solution has several positive effects:
Effective coagulation
No damage or tearing of the coagulated vessels
after coagulation
Even coagulation with constant power output
NaCl solution optimizes the electrical contact
ERBE Elektromedizin GmbH
Waldhoernlestrasse 17
72072 Tuebingen
Germany
Phone +49 7071 755-0
Fax +49 7071 755-179
[email protected]
www.erbe-med.com
09.09
The forceps can be disinfected in the thermodisinfector at a
temperature of 95°C or in the autoclave at a temperature of 138°C.
85100-142
Due to these advantages the surgical procedure can be carried out in a
shorter period of time as the instrument rarely requires cleaning intraoperatively. The irrigation solution is connected to a standard infusion
apparatus with an adjustable drip rate via the cylindrical clip.
© ERBE Elektromedizin GmbH 2009
Irrigation during coagulation