GAAB Bipolar Forceps EndoWorld for use in neuroendoscopy ®

EndoWorld®
NEURO 17 03/2012-E
GAAB Bipolar Forceps
for use in neuroendoscopy
GAAB Bipolar Forceps for use in Neuroendoscopy
KARL STORZ has an extensive portfolio of bipolar instruments on offer to meet today’s
requirements on bipolar coagulation systems. The range has now been extended with
a further pair of bipolar TAKE-APART® forceps.
These bipolar forceps have been specially developed for use in neuroendoscopy and
can be introduced through the working channel of the GAAB neuroendoscope.
Bipolar coagulation is generally preferred in neurosurgery because the circuit is
closed, which avoids neighboring structures’ being damaged accidentally. In contrast
to a bipolar electrode, bipolar forceps can be used to grasp a tissue bridge, hold
it in place and thereby coagulate it particularly effectively while applying additional
pressure to the hemorrhaging. This contributes just as importantly to the hemostasis
as the coagulation itself. In addition, the tissue filaments can be dissected without
hemorrhaging; the application of cutting diathermy is also possible. These forceps are
thus an important complement to the bipolar coagulation electrode and monopolar
diathermy.
The TAKE-APART® bipolar forceps can be completely dismantled and are thus very
easy to clean. The handle and the sheath are reusable and autoclavable. The inserts
for these forceps are disposable products and are supplied in packs of 5.
2 3
Features:
• For use through the working channel of the GAAB neuroendoscope
[(Art. no. 28096 AGA (telescope) and 28162 BS (sheath)]
• For all intraventricular interventions:
Ventriculostomy, colloid and arachnoid cysts and tumor biopsies
• Dimensions:
Sheath dia.: 2.4 mm x 26 cm
Jaws dia.: 1 mm, flat
• Pistol handle for optimal endoscopic ergonomics
• Reusable, autoclavable forceps with disposable inserts for
a cost-effective solution
• Can be used with all high-frequency devices via the corresponding
bipolar cable from KARL STORZ
28162 BDL TAKE-APART® Bipolar Grasping Forceps,
size 2.4 mm, length 26 cm, with flat jaws,
including:
Bipolar Ring Handle
Outer Sheath
Working Insert, package of 5, disposable
KARL STORZ GmbH & Co. KG
Mittelstraße 8, 78532 Tuttlingen, Germany
Postbox 230, 78503 Tuttlingen, Germany
Phone: +49 (0)7461 708-0
Fax: +49 (0)7461 708-105
E-Mail: [email protected]
www.karlstorz.com
KARL STORZ Endoscopy-America, Inc.
2151 East Grand Avenue
El Segundo, CA 90245-5017, USA
Phone: +1 424 218-8100
Phone toll free: 800 421-0837 (US only)
Fax: +1 424 218-8525
Fax toll free: 800 321-1304 (US only)
E-Mail: [email protected]
96022017 NEURO 17 03/2012/EW-E
www.karlstorz.com
EndoWorld®