© Siemens AG 2009 Level instruments Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 ■ Overview ■ Application MultiRanger can be used on different materials, including fuel oil, municipal waste, acids, woodchips or on materials with high angles of repose. MultiRanger offers true dual point monitoring, digital communications with built-in Modbus® RTU via RS-485, as well as compatibility with SIMATIC PDM, allowing PC configuration and setup. MultiRanger features Sonic Intelligence® advanced echo-processing software for increased reading reliability. MultiRanger 100 offers cost-effective level alarming, as well as on/off and alternating pump control. MultiRanger 200 will monitor open channel flow and features more advanced relay alarming and pump control functions as well as volume conversion. It is compatible with chemical-resistant Echomax® transducers that can be used in hostile environments at temperatures as high as +145 °C (+293 °F). • Key Applications: wet wells, flumes/weirs, bar screen control, hoppers, chemical storage, liquid storage, crusher bins, dry solids storage 5 MultiRanger is a versatile short to medium-range ultrasonic single and multi-vessel level monitor/controller for virtually any application in a wide range of industries. The MultiRanger is available in wall or panel mounting options. ■ Benefits • Digital input for back-up level overide from point level device • Communication using built-in Modbus RTU via RS-485 • Compatible with SmartLinx system and SIMATIC PDM configuration software • Single or dual point level monitoring • Auto False-Echo Suppression for fixed obstruction avoidance • Differential amplifier transceiver for common mode noise reduction and improved signal-to-noise ratio • MultiRanger 100: level measurements, simple pump control and level alarm functions • MultiRanger 200: level, volume and flow measurements in open channels, differential control, extended pump control and alarm functions • Wall and panel mounting options 5/138 ■ Design Siemens FI 01 · 2010 © Siemens AG 2009 Level instruments Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 ■ Technical specifications Mode of Operation Design Measuring principle Ultrasonic level measurement Measuring range 0.3 to 15 m (1 to 50 ft) • Weight - Wall mount 1.37 kg (3.02 lbs) Measuring points 1 or 2 - Panel mount 1.50 kg (3.31 lbs) • Material (enclosure) Input • Analog (MultiRanger 200 only) 0 to 20 mA or 4 to 20 mA, from alternate device, scaleable • Discrete 10 to 50 V DC switching level Logical 0 =< 0.5 V DC Logical 1 = 10 to 50 V DC Max. 3 mA Output Polycarbonate • Degree of protection (enclosure) - Wall mount IP65/Type 4X/NEMA 4X - Panel mount IP54/Type 3/NEMA 3 Electrical connection • Transducer and mA output signal 2-core copper conductor, twisted, shielded, 0.5 to 0.75 mm² (22 to 18 AWG), Belden® 8760 or equivalent is acceptable • Echomax® transducer 44 kHz • Ultrasonic transducer Compatible transducers: ST-H and Echomax series XPS-10/10F, XPS 15/15F, XCT-8, XCT-12 and XRS-5 • Max. separation between transducer and transceiver 365 m (1200 ft) Displays and controls • Relays Rating 5 A at 250 V AC, non-inductive 100 x 40 mm (4 x 1.5") multi-block LCD with backlighting • Programming Programming using hand-held programmer, SIMATIC PDM or via PC with Dolphin Plus software - Version with 1 relay (MultiRanger 100 only) 1 SPST Form A - Version with 3 relays 2 SPST Form A/1 SPDT Form C Power supply - Version with 6 relays 4 SPST Form A/2 SPDT Form C • AC version 100 to 230 V AC ± 15 %, 50/60 Hz, 36 VA (17 W) • DC version 12 to 30 V DC (20 W) Certificates and approvals • CE, C-TICK2) • Lloyd’s Register of Shipping • ABS Type Approval • FM, CSAUS/C, UL listed • CSA Class I, Div. 2, Groups A, B, C and D, Class II, Div.2, Groups F and G, Class III (wall mount only), ATEX II 3D Communication • RS-232 with Modbus RTU or ASCII via RJ-11 connector • RS-485 with Modbus RTU or ASCII via terminal strips • Optional: SmartLinx® cards for - PROFIBUS DP - DeviceNetTM - Allen-Bradley® Remote I/O • mA output 0 to 20 mA or 4 to 20 mA - Max. load 750 Ω, isolated - Resolution 0.1% of range Accuracy • Error in measurement 0.25% of range or 6 mm (0.24"), whichever is greater • Resolution 0.1 % of measuring range1) or 2 mm (0.08"), whichever is greater • Temperature compensation • -50 to +150 °C (-58 to +302 °F) • Integral temperature sensor • External TS-3 temperature sensor (optional) • Programmable fixed temperature values Rated operating conditions Installation conditions • Location 1) Indoor/outdoor • Installation category II • Pollution degree 4 2) Program range is defined as the empty distance to the face of the transducer plus any range extension EMC performance available on request Ambient conditions • Ambient temperature (housing) -20 to +50 °C (-4 to +122 °F) Siemens FI 01 · 2010 5/139 5 © Siemens AG 2009 Level instruments Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 Selection and Ordering data Order No. L) 7 M L 5 0 3 3 MultiRanger 100/200 Versatile short to medium-range ultrasonic single 7 7 7 77 - 77 and multi-vessel level monitor/controller for virtually any application in a wide range of industries Versions MultiRanger 100, level measurement only MultiRanger 200, level, volume, flow and differential measurements Instruction manual English French Spanish C) 7ML1998-5FB06 C) 7ML1998-5FB13 C) 7ML1998-5FB23 German C) 7ML1998-5FB34 Mounting, enclosure design Wall mount, standard enclosure Wall mount, 4 entries, 4 M20 cable glands included Panel mount (CE, CSAUS/C, FM, UL) Power supply 100 to 230 V AC 12 to 30 V DC 1 2 A B C C) 7ML1998-5QD83 Quick Start guide, multi-language Note: The instruction manual should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. A B Number of measurement points Single point version Dual point version 5 Selection and Ordering data Order No. L) 7 M L 5 0 3 3 MultiRanger 100/200 Versatile short to medium-range ultrasonic single 7 7 7 77 - 77 and multi-vessel level monitor/controller for virtually any application in a wide range of industries Other instruction manuals SmartLinx Allen-Bradley Remote I/O, English SmartLinx PROFIBUS DP, English SmartLinx PROFIBUS DP, German 0 1 Communication (SmartLinx) Without module SmartLinx® Allen-Bradley® Remote I/O module SmartLinx PROFIBUS DP module C) 7ML1998-1AQ12 SmartLinx PROFIBUS DP, French C) 7ML1998-1BH02 SmartLinx DeviceNet, English Note: The appropriate SmartLinx instruction manual should be ordered as a separate line on the order. 0 1 2 SmartLinx DeviceNetTM module See SmartLinx product page 5/301 for more information. 3 Output relays 3 relays (2 Form A, 1 Form C), 250 V AC 6 relays (4 Form A, 2 Form C), 250 V AC 1 relay (1 Form A), 250 V AC (available on MultiRanger 100 model only) A B C Order code Please add "-Z" to Order No. and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97")]: Measuring-point number/identification (max. 16 characters) specify in plain text Accessories Handheld programmer Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one text line, suitable for enclosure 1 2 3 Approvals General Purpose CE, FM, CSAUS/C, UL listed, C-TICK CSA Class I, Div. 2, Groups A, B, C and D; Class II, Div 2, Groups F and G; Class III1) ATEX II 3D2) Further designs 7ML1830-2AK 7ML1930-1AC TS-3 Temperature Sensor - see TS-3 on page 5/186 SITRANS RD100 Remote display see RD100 on page 5/304 SITRANS RD200 Remote display see RD200 on page 5/306 Spare parts Power Supply Board (100 to 230 V AC) Power Supply Board (12 to 30 V DC) Display Board C) 7ML1830-1MD C) 7ML1830-1ME C) 7ML1830-1MF See SmartLinx product page 5/301 for more information. 1) Y15 C) 7ML1998-1AP03 C) 7ML1998-1AQ03 C) 7ML1998-1AQ33 2) For wall mount applications only For standard enclosure wall mount, option A only C) Subject to export regulations AL: N, ECCN: EAR99 L) Subject to export regulations AL: N, ECCN: 3A991X ®Modbus is a registered trademark of Schneider Electric. ®Belden is a registered trademark of Belden Wire and Cable Company. ® Allen-Bradley is a registered trademark of Rockwell Automation. TMDeviceNet is a trademark of Open DeviceNet Vendor Association (ODVA) 5/140 Siemens FI 01 · 2010 © Siemens AG 2009 Level instruments Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 ■ Dimensional drawings ■ Schematics See note 1 DC version DISCRETE INPUTS Relays shown in released state 5 Notes 1. Use 2-core copper wire, twisted, with shield, for expansion up to 365 m (1200 ft.). Route cable in grounded metal conduit, separate from other cables. 2. Verify that all system components are installed in accordance with instructions. 3. Connect all cable shields to the MultiRanger Shield Connections. Avoid differential ground potentials by not connecting cable shields to ground (earth) anywhere else. 4. Keep exposed conductors on shielded cables as short as possible to reduce noise on the line caused by stray transmissions and noise pickup. MultiRanger connections MultiRanger dimensions Siemens FI 01 · 2010 5/141 © Siemens AG 2009 Level instruments Continuous level measurement - Ultrasonic controllers HydroRanger Plus ■ Overview Output • Ultrasonic transducer 44 kHz • Relays 5 alarm/control relays, 1 SPDT Form C per relay, rated 5 A at 250 V AC, resistive load • mA output 0/4 to 20 mA, optically isolated - Max. load 1 kΩ - Resolution 0.1 % of 20 mA Accuracy 5 HydroRanger Plus is an ultrasonic level controller for control of wet wells and reservoir pump operations, differential control and open channel flow monitoring, using energy-saving algorithms. • Error in measurement 0.25% of range or 6 mm (0.24"), whichever is greater • Resolution 0.1% of measuring range or 2 mm (0.08"), whichever is greater1) • Temperature compensation -50 to +150 °C (-58 to +302 °F) • Integral temperature sensor • External TS-3 temperature sensor (optional) • Programmable fixed temperature Rated operating conditions Ambient conditions ■ Benefits • Ambient temperature for enclosure • Outputs for alarms, chart recorders, controllers and integration of existing systems • Monitors wet wells, weirs and flumes • Energy-saving function with built-in real-time clock • Special control mode to reduce grease rings and other deposits • Integral temperature compensation • Pump performance monitoring • System monitoring and network analysis ■ Application The system is effective in wet wells, weirs, and flumes where foam and turbulence are typical operating conditions. It can be customized to meet your specific application needs – from measuring flow rate in a narrow flume to volume in a ferric chloride storage bank. The system consists of the electronics housed in a wall-mounted enclosure and a hermetically sealed, corrosion-resistant Echomax® transducer. These components can be separated by up to 365 m (1200 ft). Optional submergence shields ensure consistent operation in wet wells where the transducer may be submerged during flooding from rainfall or a power outage. Siemens patented detection software can differentiate between a submerged condition and a high level. • Key Applications: wet wells, weirs, flumes • Rack mount DIN 3 HU/14 pitch, 4 rail plug-in unit suitable for standard 84 pitch (19") rack • Panel mount Suitable for standard panel cutout DIN 43700, 72 x 144 mm, 100 mm center height • Degree of protection (wall mount) IP65/NEMA 4X/Type 4X • Weight (rack and panel mount) 0.87 kg (1.9 lbs) • Weight (wall mount) 1.5 kg (3.3 lbs) • Material (enclosure) Polyester/polycarbonate alloy Electrical connection Commercially available copper conductor according to local requirements, rated 250 V/5 A • Ultrasonic transducer cable exten- RG 62-A/U coaxial cable with low capacitance sion • mA output signal 2-core copper conductor, twisted, shielded, 0.5 to 0.75 mm² (22 to 18 AWG), Belden® 8760 or equivalent is acceptable Power supply 100/115/200/230 V AC, ± 15%, 50/60 Hz, 15 VA and/or 9 to 30 V DC, 8 W • Ultrasonic transducer Compatible transducers: ST-H and Echomax series XPS-10/10F, XPS 15/15F, XCT-8, XCT-12 and XRS-5 Displays and controls ■ Technical specifications Mode of operation Measuring principle Ultrasonic level measurement Measuring range 0.3 to 15 m (1 to 50 ft) Measuring points 1 or 2 Rack and panel mount 75 x 20 mm (3 x 0.8") LCD (selectable backlighting) Wall mount 100 x 40 mm (4 x 1.5") multifield LCD, backlit Programming Removable programmer or optional Dolphin Plus Memory EEPROM (non-volatile), no backup battery required Certificates and approvals CE2), FM, CSAUS/C, C-TICK 1) 2) ® 5/142 Siemens FI 01 · 2010 -20 to +50 °C (-4 to +122 °F) Design The measuring range corresponds to the distance from the zero point to the sensor face, plus any range extension. EMC certificate available on request Belden is a registered trademark of Belden Wire and Cable Company. © Siemens AG 2009 Level instruments Continuous level measurement - Ultrasonic controllers HydroRanger Plus Selection and Ordering data Order No. Selection and Ordering data Order No. L) 7 M L 1 0 2 5 HydroRanger Plus, rack and panel mount Non-contacting ultrasonic echo ranging technology 777 0 1 monitor that comes standard with a backlit display Measuring range: 0.3 m to 15 m (1 to 50 ft) L) 7 M L 1 0 2 8 HydroRanger Plus, wall mount Non-contacting ultrasonic echo ranging technology 7A77 0 monitor that comes standard with a backlit display Measuring range: 0.3 m to 15 m (1 to 50 ft) Mounting/device version Version for 19" rack (requires terminal block; see accessories) Version for panel Input voltage 100 V AC, 9 to 30 V DC 115 V AC, 9 to 30 V DC 1 2 200 V AC, 9 to 30 V DC 230 V AC, 9 to 30 V DC 3 4 1 2 Approvals CE (EN 61326), CSAUS/C, FM, C-TICK C Input voltage 100 V AC, 9 to 30 V DC 115 V AC, 9 to 30 V DC A B 200 V AC, 9 to 30 V DC 230 V AC, 9 to 30 V DC C D Order code Further designs Stainless steel tag [69 x 50 mm (2.71 x 1.97")]: Measuring-point number/identification (max. 16 characters) specify in plain text Y15 Instruction manual C) English C) French C) German Note: The instruction manual should be ordered as a separate line item on the order. Order No. 7ML1998-1AC02 7ML1998-1AC12 7ML1998-1AC32 This device is shipped with the Siemens Milltronics manual CD containing the complete Quick Start and instruction manual library. Spare parts Card, Analog HydroRanger Plus Rack/Panel Card, daughter Card, display, backlit C Mounting/enclosure version Standard enclosure (NEMA 4X) Standard enclosure prepared for five M20 cable glands 1 3 Order code Further designs Please add "-Z" to Order No. and specify Order code(s). Accessories Handheld programmer Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one text line suitable for enclosures Terminal block for rack mount TS-3 Temperature Sensor - see TS-3 on page 5/186 SITRANS RD100 Remote display see RD100 on page 5/304 SITRANS RD200 Remote display see RD200 on page 5/306 Approvals CE; FM General Purpose; CSA Class I, Div. 2, C-TICK Please add "-Z" to Order No. and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97")]: Measuring-point number/identification (max. 16 characters) specify in plain text Y15 Instruction manual C) English C) French C) German Note: The instruction manual should be ordered as a separate line item on the order. Order No. 7ML1998-1AC02 7ML1998-1AC12 7ML1998-1AC32 5 This device is shipped with the Siemens Milltronics manual CD containing the complete Quick Start and instruction manual library. 7ML1830-2AC 7ML1930-1AC 7ML1830-1JL C) 7ML1830-1LR C) 7ML1830-1LS C) 7ML1830-1LX Accessories Handheld programmer Tag, stainless steel, 12 x 45 mm (0.47 x 1.77"), one text line suitable for enclosures M20 cable gland kit (6 M20 cable glands, 6 M20 nuts, 3 stop plugs) 7ML1830-2AC 7ML1930-1AC 7ML1830-1GM TS-3 Temperature Sensor - see TS-3 on page 5/186 SITRANS RD100 Remote display see RD100 on page 5/304 SITRANS RD200 Remote display see RD200 on page 5/306 Spare parts Card, mother main Card, daughter Card, display C) 7ML1830-1LV C) 7ML1830-1LW C) 7ML1830-1LU C) Subject to export regulations AL: N, ECCN: EAR99 L) Subject to export regulations AL: N, ECCN: 3A991X Siemens FI 01 · 2010 5/143 © Siemens AG 2009 Level instruments Continuous level measurement - Ultrasonic controllers HydroRanger Plus ■ Dimensional drawings ■ Schematics 5 HydroRanger Plus dimensions 5/144 Siemens FI 01 · 2010 HydroRanger Plus connections, rack and panel mount © Siemens AG 2009 Level instruments Continuous level measurement - Ultrasonic controllers HydroRanger Plus HydroRanger Plus connections, wall mount 5 Siemens FI 01 · 2010 5/145
© Copyright 2024