DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXM20PVMA FTXM25PVMA FTXM35PVMA FTXM46PVMA FTKM20PVMA FTKM25PVMA FTKM35PVMA FTKM46PVMA 00_CV_3P372379-1C.indd 1 7/9/2014 11:07:13 AM Features Enhanced comfort and energy savings INTELLIGENT EYE TheINTELLIGENTEYEsensordetectshumanmovementina room.Ifnooneisintheroomformorethan20 minutes,the operationautomaticallychangestoenergysavingoperation. Page 15 WEEKLY TIMER Upto4 timersettingscanbesavedforeachdayoftheweek accordingtoyourfamily’slifestyle.TheWEEKLYTIMERallows youtoseton/offtimesandthedesiredtemperature. Page 22 Other functions COMFORT AIRFLOW OUTDOOR UNIT QUIET Theairflowdirectionisupwardwhilein COOLoperation,anddownwardwhile inHEAToperation.Thisfunction preventscoldorwarmairfromblowing directlyonyourbody. Page 15 OUTDOORUNITQUIEToperation assuresalownoiselevelofthe outdoorunit.Thisfunctionisuseful tomaintainaquietneighbourhood. Page 19 1 01_EN_3P372379-1C.indd 1 7/9/2014 11:08:03 AM Contents Read Before Operation SafetyPrecautions.......................................... 3 NamesofParts............................................... 5 PreparationBeforeOperation......................... 9 Basic Operation AUTO·DRY·COOL·HEAT· FANOperation................................... 11 AdjustingtheAirflowDirection........... 13 AdjustingtheAirflowRate.................. 14 Useful Functions COMFORTAIRFLOW/ INTELLIGENTEYEOperation........... 15 POWERFULOperation...................... 18 ECONO/OUTDOORUNITQUIET Operation........................................... 19 TIMER Operation ON/OFFTIMEROperation................ 20 WEEKLYTIMEROperation................ 22 Care CareandCleaning....................................... 28 When the Need Arises ECONO Thisfunctionenablesefficientoperationby limitingthemaximumpowerconsumption. Itisusefulwhenusingtheairconditioner andotherelectricaldevicessimultaneously onasharedelectricalcircuit. Page 19 FAQ.............................................................. 33 Troubleshooting........................................... 34 2 01_EN_3P372379-1C.indd 2 7/9/2014 11:08:06 AM Read Before Operation Safety Precautions Read the precautions in this manual carefully before operating the unit. This appliance is filled with R32. •Keepthismanualwheretheusercaneasilyfindit. •TheprecautionsdescribedhereinareclassifiedasWARNINGandCAUTION.Theybothcontainimportantinformationregarding safety.Besuretoobserveallprecautionswithoutfail. WARNING CAUTION Failuretofollowtheseinstructionsproperlymayresultin personalinjuryorlossoflife. Neverattempt. Failuretofollowtheseinstructionsproperlymayresultin propertydamageorpersonalinjury,whichmaybeserious dependingonthecircumstances. Besuretofollowthe instructions. Besuretoestablishanearth connection. •Afterreading,keepthismanualinaconvenientplacesothatyoucanrefertoitwhenevernecessary.Iftheequipmentis transferredtoanewuser,besurealsotohandoverthemanual. WARNING • Donotusemeanstoacceleratethedefrostingprocessortoclean,otherthanthoserecommendedbythemanufacturer. • Theappliancemustbestoredinaroomwithoutcontinuouslyoperatingignitionsources(forexample:openflames,an operatinggasapplianceoranoperatingelectricheater). • Donotpierceorburn. • Beawarethatrefrigerantsmaynotcontainanodour. • Theappliancemustbeinstalled,operatedandstoredinaroomwithafloorarealargerthan4.7m2. • Toavoidfire,explosionorinjury,donotoperatetheunitwhenharmfulgases(e.g.flammableorcorrosive)aredetectedneartheunit. • Beawarethatprolonged,directexposuretocoolorwarmairfromtheairconditioner,ortoairthatistoocoolortoo warm,canbeharmfultoyourphysicalconditionandhealth. • Donotplaceobjects,includingrods,yourfingers,etc.,intheairinletoroutlet.Productdamageorpersonalinjurymay resultduetocontactwiththeairconditioner’shigh-speedfanblades. • Donotattempttorepair,dismantle,reinstallormodifytheairconditioneryourselfasthismayresultinwaterleakage, electricshocksorfirehazards. • Donotuseflammablesprayneartheairconditioner,orotherwisefiremayresult. • Donotusearefrigerantotherthantheoneindicatedontheoutdoorunit(R32)wheninstalling,movingorrepairing. Usingotherrefrigerantsmaycausetroubleordamagetotheunit,andpersonalinjury. • Toavoidelectricshocks,donotoperatewithwethands. • Bewareoffireincaseofrefrigerantleakage.Iftheairconditionerisnotoperatingcorrectly,i.e.notgeneratingcoolor warmair,refrigerantleakagecouldbethecause.Consultyourdealerforassistance.Therefrigerantwithintheair conditionerissafeandnormallydoesnotleak. However,intheeventofaleakage,contactwithanakedburner,heaterorcookermayresultingenerationofnoxious gas.Donotusetheairconditioneruntilaqualifiedservicepersonconfirmsthattheleakagehasbeenrepaired. • Donotattempttoinstallorrepairtheairconditioneryourself.Improperworkmanshipmayresultinwaterleakage,electric shocksorfirehazards.Pleasecontactyourlocaldealerorqualifiedpersonnelforinstallationandmaintenancework. • Iftheairconditionerismalfunctioning(givingoffaburningodour,etc.),turnoffpowertotheunitandcontactyour localdealer.Continuedoperationundersuchcircumstancesmayresultinafailure,electricshocksorfirehazards. • Besuretoinstallanearthleakagecircuitbreaker.Failuretoinstallanearthleakagecircuitbreakermayresultinelectricshocksorfire. • Besuretoearththeunit.Donotearththeunittoautilitypipe,lightningconductorortelephoneearthlead.Imperfect earthingmayresultinelectricshocks. CAUTION • Donotusetheairconditionerforpurposesotherthanthoseforwhichitisintended.Donotusetheairconditionerfor coolingprecisioninstruments,food,plants,animalsorworksofartasthismayadverselyaffecttheperformance, qualityand/orlongevityoftheobjectconcerned. • Donotexposeplantsoranimalsdirectlytotheairflowfromtheunitasthismaycauseadverseeffects. • Donotplaceappliancesthatproducenakedflamesinplacesexposedtotheairflowfromtheunitasthismayimpaircombustionoftheburner. 3 01_EN_3P372379-1C.indd 3 7/9/2014 11:08:06 AM Read Before Operation CAUTION • Donotblocktheairinletsnoroutlets.Impairedairflowmayresultininsufficientperformanceortrouble. • Donotsitontheoutdoorunit,putthingsontheunit,orpulltheunit.Doingsomaycauseaccidents,suchasfallingor topplingdown,thusresultingininjury,productmalfunctioning,orproductdamage. • Donotplaceobjectsthataresusceptibletomoisturedirectlybeneaththeindoororoutdoorunits.Undercertain conditions,condensationonthemainunitorrefrigerantpipes,airfilterdirtordrainblockagemaycausedripping, resultinginfoulingorfailureoftheobjectconcerned. • Afterprolongeduse,checktheunitstandanditsmountsfordamage.Iftheyareleftinadamagedcondition,theunit mayfallandcauseinjury. • Toavoidinjury,donottouchtheairinletoraluminiumfinsoftheindoororoutdoorunits. • Theapplianceisnotintendedforusebyunattendedyoungchildrenorinfirmpersons.Impairmentofbodilyfunctions andharmtohealthmayresult. • Childrenshouldbesupervisedtoensurethattheydonotplaywiththeunitoritsremotecontroller.Accidental operationbyachildmayresultinimpairmentofbodilyfunctionsandharmhealth. • Avoidimpactstotheindoorandoutdoorunits,orotherwiseproductdamagemayresult. • Donotplaceflammableitems,suchasspraycans,within1moftheairoutlet. Thespraycansmayexplodeasaresultofhotairfromtheindoororoutdoorunits. • Becarefulnottoletpetsurinateontheairconditioner.Urinationontheairconditionermayresultinelectricshocksorfire. • Donotwashtheairconditionerwithwater,asthismayresultinelectricshocksorfire. • Donotplacewatercontainers(vases,etc.)abovetheunit,asthismayresultinelectricshocksorfirehazardsiftheyshouldtoppleover. • Toavoidoxygendepletion,ensurethattheroomisadequatelyventilatedifequipmentsuchasaburnerisused togetherwiththeairconditioner. • Beforecleaning,besuretostopunitoperationandturnoffthecircuitbreaker.Otherwise,anelectricshockandinjury mayresult. • Onlyconnecttheairconditionertothespecifiedpowersupplycircuit.Powersuppliesotherthantheonespecifiedmay resultinelectricshocks,overheatingandfires. • Arrangethedrainhosetoensuresmoothdrainage.Imperfectdrainagemaycausewettingofthebuilding,furniture,etc. • Donotplaceobjectsindirectproximityoftheoutdoorunitanddonotletleavesandotherdebrisaccumulatearound theunit.Leavesareahotbedforsmallanimalswhichcanentertheunit.Onceinsidetheunit,suchanimalscancause malfunctions,smokeorfireiftheycomeintocontactwithelectricalparts. • Donotplaceobjectsaroundtheindoorunit. Doingsomayhaveanadverseinfluenceontheperformance,productquality,andlifeoftheairconditioner. P004 Installation site Toinstalltheairconditionerinthefollowingtypesofenvironments,consultyourdealer. •Placeswithanoilyenvironmentorwheresteamorsootoccurs. •Saltyenvironmentssuchascoastalareas. •Placeswheresulphidegasoccurssuchashotsprings. •Placeswheresnowmayblocktheoutdoorunit. Besuretofollowtheinstructionsbelow. •Theindoorunitisatleast1mawayfromanytelevisionorradioset(unitmaycauseinterferencewiththepictureorsound). •Thedrainfromtheoutdoorunitmustbedischargedtoaplaceofgooddrainage. Consider nuisance to your neighbours from noises Forinstallation,chooseaplaceasdescribedbelow. •Aplacesolidenoughtobeartheweightoftheunitandwhichdoesnotamplifytheoperationnoiseorvibration. •Aplacefromwheretheairdischargedfromtheoutdoorunitortheoperationnoisewillnotannoyyourneighbours. Electrical work Forthepowersupply,besuretouseaseparatepowercircuitdedicatedtotheairconditioner. System relocation Relocatingtheairconditionerrequiresspecializedknowledgeandskills.Pleaseconsultyourdealerifrelocation isnecessaryformovingorremodelling. 4 01_EN_3P372379-1C.indd 4 7/9/2014 11:08:07 AM Read Before Operation Names of Parts Indoor Unit Front panel Air inlet Panel tab INTELLIGENT EYE sensor Air outlet • Detectsthemovementsof peopleandautomatically switchesbetweennormal operationandenergysaving operation. Page 15-17 Model name plate Louvres (vertical blades) • Thelouvresareinsideoftheair outlet. Page 13 Indoor temperature sensor Flaps (horizontal blades) • Detectstheairtemperature aroundtheunit. Page 13 Display OPERATION lamp (green) Signal receiver • Receivessignalsfromtheremote controller. • Whentheunitreceivesasignal,you willhearabeepsound. Case Sound type Operationstart beep-beep Settingchanged beep Operationstop longbeep TIMER lamp (orange) Page 20,21,24,26 INTELLIGENT EYE lamp (green) Page 16 Indoor unit ON/OFF switch • Pressthisswitchoncetostartoperation. Pressonceagaintostopit. • Fortheoperationmodesetting,refertothefollowingtable. Model Mode Temperature setting Airflow rate HEATPUMP AUTO 25°C AUTO COOLINGONLY COOL 22°C AUTO • Thisswitchcanbeusedwhentheremotecontrollerismissing. 5 01_EN_3P372379-1C.indd 5 7/9/2014 11:08:07 AM Read Before Operation Open the front panel Air filter Titanium apatite photocatalytic air-purifying filter Outdoor Unit •Theappearanceoftheoutdoorunitmaydifferbetweendifferentmodels. Air inlet (back and side) Outdoor temperature sensor (back) Drain hose Earth terminal (inside) Air outlet Model name plate Refrigerant pipes and inter-unit wire 6 01_EN_3P372379-1C.indd 6 7/9/2014 11:08:08 AM Read Before Operation Names of Parts Remote Controller Signal transmitter Display (LCD) Receiver • Tousetheremotecontroller,aimthe transmitterattheindoorunit.Ifthereis anythingblockingthesignalsbetween theunitandtheremotecontroller,such asacurtain,theunitmaynotoperate. • Themaximumtransmissiondistanceis about7m. • Displaysthecurrentsettings. (Inthisillustration,eachsectionis shownwithallitsdisplaysonforthe purposeofexplanation.) TEMPERATURE adjustment button • Changesthetemperaturesetting. Page 12 FAN setting button • Selectstheairflowratesetting. Page 14 ON/OFF button • Pressthisbuttononcetostart operation. Pressonceagaintostopit. Page 11 POWERFUL button • POWERFULoperation. Page 18 Front cover • Openthefrontcover. HEATPUMPmodel COOLINGONLYmodel Page 8 ARC466A16 ARC466A14 7 01_EN_3P372379-1C.indd 7 7/9/2014 11:08:10 AM Read Before Operation Open the front cover MODE selector button • Selectstheoperationmode. (AUTO/DRY/COOL/HEAT/FAN) Page 11 ECONO/QUIET button • ECONO/OUTDOORUNIT QUIEToperation. Page 19 COMFORT/SENSOR button • COMFORTAIRFLOWand INTELLIGENTEYEoperation. SWING button • Adjuststheairflowdirection. Page 13 Page 15 OFF TIMER button (NIGHT SET mode) Page 21 : WEEKLY button : PROGRAMME button : COPY button TIMER CANCEL button : BACK button • Cancelsthetimersetting. Page 20,21 : NEXT button • WEEKLYTIMERoperation. Page 22 • Cannotbeusedforthe WEEKLYTIMERoperation. ON TIMER button SELECT button • Changestheclock,ON/OFF TIMERandWEEKLYTIMER settings. CLOCK button Page 20 Page 10 8 01_EN_3P372379-1C.indd 8 7/9/2014 11:08:14 AM Read Before Operation Preparation Before Operation To insert the batteries 2 1 3 Position + and – correctly! 1. Slide the front cover to take it off. 2. Insert 2 dry batteries AAA.LR03 (alkaline). 3. Replace the front cover. To fix the remote controller holder to a wall Remote controller 1. Choose a place from where the signals reach the unit. 2. Fix the holder to a wall, a pillar, or similar location with the screws supplied with the holder. Screws Remote controller holder 3. Place the remote controller in the remote controller holder. Turn on the circuit breaker •Afterthepoweristurnedon,theflapsoftheindoorunitopenandcloseoncetosetthe referenceposition. NOTE Notes on batteries •Whenreplacingthebatteries,usebatteriesofthesametype,andreplaceboth oldbatteriestogether. •Thebatterieswilllastforabout1year.Iftheremotecontrollerdisplaybeginstofadeandthepossibletransmissionrangebecomesshorterwithin ayear,however,replacebothbatterieswithnew,sizeAAA.LR03(alkaline). •Thebatteriessuppliedwiththeremotecontrollerareforinitialoperation.Thebatteriesmayrunoutinlessthan1year. Note on remote controller •Donotdroptheremotecontroller.Donotgetitwet. 9 01_EN_3P372379-1C.indd 9 7/9/2014 11:08:15 AM Read Before Operation To set the clock 1. Press . “ “ ”isdisplayedontheLCD. ”and“ ”blink. 2. Press to set the current day of the week. 3. Press . “ ”blinks. 4. Press to set the clock to the present time. •Holdingdown or rapidlyincreasesordecreasesthedisplayedtime. 5. Press . •Pointtheremotecontrollerattheindoorunitwhenpressingthebuttons. “ ”blinks. NOTE Note on setting the clock •Iftheindoorunit’sinternalclockisnotsettothecorrecttime,theON/OFFTIMERandWEEKLYTIMERwillnotoperatepunctually. 10 01_EN_3P372379-1C.indd 10 7/9/2014 11:08:16 AM Basic Operation AUTO · DRY · COOL · HEAT · FAN Operation Theairconditioneroperateswiththeoperationmodeofyourchoice. Fromthenexttimeon,theairconditionerwilloperatewiththesameoperation mode. To start operation 1. Press and select a operation mode. •Eachpressingofthebuttonchangesthemodesettinginsequence. HEAT PUMP model COOLING ONLY model 2. Press AUTO DRY COOL DRY COOL FAN HEAT FAN . •“ ”isdisplayedontheLCD. •TheOPERATIONlamplightsgreen. Display To stop operation Press again. •“ ”disappearsfromtheLCD. •TheOPERATIONlampgoesoff. NOTE Notes on AUTO operation •InAUTOoperation,thesystemselectsanappropriateoperationmode(COOLorHEAT)basedontheindoortemperatureandstartsthe operation. •Thesystemautomaticallyreselectssettingataregularintervaltobringtheindoortemperaturetotheuser-settinglevel. Note on DRY operation •Eliminateshumiditywhilemaintainingtheindoortemperatureasmuchaspossible.Itautomaticallycontrolstemperatureandairflowrate,so manualadjustmentofthesefunctionsisunavailable. 11 01_EN_3P372379-1C.indd 11 7/9/2014 11:08:17 AM Basic Operation To change the temperature setting Press •Press . toraisethetemperatureandpress COOL operation 18 –32°C HEAT operation tolowerthetemperature. AUTO operation DRY or FAN operation 18 –30°C Thetemperaturesettingcannotbe changed. 10 –30°C Tips for saving energy Keeping the temperature setting at a moderate level helps save energy. •Recommendedtemperaturesetting −Forcooling:26-28°C −Forheating:20-24°C Cover windows with a blind or a curtain. •Blockingsunlightandairfromoutdoorsincreasesthecooling(heating)effect. Keep the air filters clean. •Cloggedairfilterscauseinefficientoperationandwasteenergy.Cleanthemonceinaboutevery2 weeks. Page 30 If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn off the circuit breaker. •Theairconditioneralwaysconsumesasmallamountofelectricityevenwhileitisnotoperating. 12 01_EN_3P372379-1C.indd 12 7/9/2014 11:08:17 AM Basic Operation Adjusting the Airflow Direction Youcanadjusttheairflowdirectiontoincreaseyourcomfort. CAUTION • Alwaysusearemotecontrollertoadjusttheanglesoftheflapsandlouvres. −Ifyouattempttomovetheflapsandlouvresforciblybyhandwhentheyareswinging,themechanismmay bedamaged. −Insidetheairoutlet,afanisrotatingatahighspeed. To start auto swing Up and down airflow direction Press . •“ ”isdisplayedontheLCD. •Theflaps(horizontalblades)willbegintoswing. Right and left airflow direction Press . •“ ”isdisplayedontheLCD. •Thelouvres(verticalblades)willbegintoswing. The 3-D airflow direction Press and . •“ ”and“ ”aredisplayedontheLCD. •Theflapsandlouvresmoveinturn. or •Tocancel3-Dairflow,presseither Theflapsorlouvreswillstopmoving. again. To set the flaps or louvres at the desired position •Thisfunctioniseffectivewhiletheflapsorlouvresareinautoswingmode. Press and when the flaps or louvres reach the desired position. •Inthe3-Dairflow,theflapsandlouvresmoveinturn. ”disappearsfromtheLCD. •“ ”or“ 13 01_EN_3P372379-1C.indd 13 7/9/2014 11:08:19 AM Basic Operation Adjusting the Airflow Rate Youcanadjusttheairflowratetoincreaseyourcomfort. To adjust the airflow rate setting Press . •Eachpressingof changestheairflowratesettinginsequence. AUTO Indoor unit quiet Airflow rate 1-5 (Low to High) •Whentheairflowissetto“ ”,quietoperationstartsandnoisefromtheindoorunitwill becomequieter. •Inthequietoperationmode,theairflowrateissettoaweaklevel. AUTO, COOL, HEAT and FAN operation DRY operation Theairflowratesettingcannotbe changed. NOTE Note on airflow direction setting •Themovablerangeoftheflapsvariesaccordingtotheoperationmode. Movable range of the flaps COOL / DRY FAN HEAT Note on 3-D airflow •Using3-Dairflowcirculatescoldair,whichtendstocollectedatthebottomoftheroom,andhotair,whichtendstocollectneartheceiling, throughouttheroom,preventingareasofcoldandhotdeveloping. Note on airflow rate setting •Atsmallerairflowrates,thecooling(heating)effectisalsosmaller. 14 01_EN_3P372379-1C.indd 14 7/9/2014 11:08:20 AM Useful Functions COMFORT AIRFLOW / INTELLIGENT EYE Operation COMFORT AIRFLOW operation TheairflowdirectionisupwardwhileinCOOLoperation,anddownwardwhileinHEAToperation.This functionpreventscoldorwarmairfromblowingdirectlyontheoccupantsintheroom. INTELLIGENT EYE operation TheINTELLIGENTEYEsensordetectshumanmovementandadjuststherightandleftairflowdirection toavoidblowingairdirectlyontheperson.Ifnooneisintheroomformorethan20minutes,theoperation automaticallychangestoenergysavingoperation.TheINTELLIGENTEYEsensorworksdifferentlydependingonthesituation. [Example] A person is detected in area 1. Area 1 Area 2 People are detected in both areas. Area 1 A person is detected in area 2. Area 1 Area 2 No people are detected in the areas. Area 2 UsetheINTELLIGENTEYEoperationin combinationwiththeCOMFORTAIRFLOW operation. Theairconditionerwillswitchtoenergy-saving modeafter20minutes. *Theairflowdirectionmaydifferfromtheillustrateddirectiondependingontheactionsand movementsofthepeopleintheareas. INTELLIGENT EYE operation is useful for energy saving Energy saving operation •Ifnopresencedetectedintheroomfor20 minutes,energysavingoperationstartsautomatically. •Thisoperationchangesthetemperatureby–2°CinHEAT/+2°CinCOOL/+2°CinDRYoperationfromthesettemperature. Whentheroomtemperatureexceeds30°C,theoperationchangesthetemperatureby+1°CinCOOL/+1°CinDRYoperationfromthe settemperature. •ThisoperationdecreasestheairflowrateslightlyinFANoperationonly. 15 01_EN_3P372379-1C.indd 15 7/9/2014 11:08:20 AM Useful Functions CAUTION • DonotplacelargeobjectsneartheINTELLIGENTEYEsensor.Alsokeepheatingunitsandhumidifiers outsidethesensor’sdetectionarea.Thissensorcandetectundesirableobjects. • DonothitorviolentlypushtheINTELLIGENTEYEsensor.Thiscanleadtodamageandmalfunction. To start operation Press and select the desired mode. •Eachtime ispressed,adifferentsettingoptionisdisplayedontheLCD. •TheINTELLIGENTEYElamplightsgreen. Display •Byselecting“ ”fromthefollowingicons,theairconditionerwillswitchtoCOMFORT AIRFLOWoperationcombinedwithINTELLIGENTEYEoperation. COMFORT AIRFLOW INTELLIGENT EYE Combination blank No Setting •Whentheflaps(horizontalblades)areswinging,selectinganyofthemodesabovewill causetheflaps(horizontalblades)tostop. •Thelamplightswhenhumanmovementisdetected. COMFORT AIRFLOW / INTELLIGENT EYE operation settings Display • Blank Operationmode Explanation COMFORTAIRFLOW Theflapsadjusttheairflowdirectionupwardwhilecooling, anddownwardwhileheating. Page 15 INTELLIGENTEYE Thesensordetectsthemovementofpeopleinthesensing areasandthelouvresadjusttheairflowdirectiontoanarea wherepeoplearenotpresent.Whentherearenopeoplein thesensingareas,theairconditionerswitchestotheenergysavingmode. Page 15 COMFORTAIRFLOWand INTELLIGENTEYE TheairconditionerwillbeinCOMFORTAIRFLOWoperation combinedwithINTELLIGENTEYEoperation. Nofunction − To cancel operation Press until no icon is displayed. •TheINTELLIGENTEYElampgoesoff. 16 01_EN_3P372379-1C.indd 16 7/9/2014 11:08:21 AM Useful Functions COMFORT AIRFLOW / INTELLIGENT EYE Operation NOTE Note on COMFORT AIRFLOW operation •TheairflowratewillbesettoAUTO.Iftheupanddownairflowdirectionisselected,COMFORTAIRFLOWoperationwillbecancelled. Notes on INTELLIGENT EYE operation •Applicationrangeisasfollows. 7m 90° Horizontal angle 110° (Top view) 55° 55° 7m Vertical angle 90° (Side view) •WhiletheairconditionerisinINTELLIGENTEYEoperation,thelouvresadjusttheairflowdirectioniftherearepeopleinthesensingareasof theINTELLIGENTEYEsothattheleftwardorrightwardairflowwillnotbedirectedtothepeople. Ifnopeoplearedetectedineitherarea1or2for20minutes,theairconditionerswitchestotheenergy-savingmodewiththesettemperature shiftedby2°C. Theairconditionermayswitchtotheenergy-savingoperationeveniftherearepeopleintheareas. Thismayoccurdependingontheclothesthepeoplearewearing,ifthereisnomovementofthepeopleintheareas. •Theairflowdirectionfromthelouvreswillbeleftwardiftherearepeopleinbothareas1and2.Theairwillalsoflowleftifthereisapersonright infrontofthesensorasthesensorjudgesthattherearepeopleinbothareas. •Duetothepositionofthesensor,peoplemightbeexposedtotheairflowoftheindoorunitiftheyareclosetothefrontsideoftheindoorunit. Iftherearepeopleclosetothefrontsideoftheindoorunitorinbothareas,itisrecommendedtousetheCOMFORTAIRFLOWand INTELLIGENTEYEoperationssimultaneously.Usingbothmodestogether,theairconditionerwillnotdirecttheairflowtowardsthepeople. •Thesensormaynotdetectmovingobjectsfurtherthan7maway.(Pleaseseetheapplicationrange.) •Sensordetectionsensitivitychangesaccordingtotheindoorunitlocation,thespeedofpassers-by,temperaturerange,etc. •Thesensorcouldalsomistakenlydetectpets,sunlight,flutteringcurtainsandlightreflectedoffofmirrorsaspassers-by. •INTELLIGENTEYEoperationwillnotswitchonduringPOWERFULoperation. •NIGHTSETmode Page 21 willnotswitchonduringuseofINTELLIGENTEYEoperation. Notes on combining COMFORT AIRFLOW operation and INTELLIGENT EYE operation •TheairflowratewillbesettoAUTO.Iftheupanddownairflowdirectionisselected,COMFORTAIRFLOWoperationwillbecanceled. Priorityisgiventothefunctionofwhicheverbuttonispressedlast. •WhentheINTELLIGENTEYEsensordetectsthemovementofpeople,itadjuststheairflowdirectionupward(whileinCOOLoperation)and downward(whileinHEAToperation),byadjustingtheflaps.Whenthesensordetectspeople,thelouvreswilldirecttheairflowinsuchawaythat itwillnotbeblowndirectlyonthem.Iftherearenopeople,theairconditionerwillswitchtoenergy-savingoperationafter20minutes. 17 01_EN_3P372379-1C.indd 17 7/9/2014 11:08:22 AM Useful Functions POWERFUL Operation POWERFUL operation quickly maximizes the cooling (heating) effect in any operationmode.Inthismode,theairconditioneroperatesatmaximumcapacity. To start POWERFUL operation Press during operation. •“ ”isdisplayedontheLCD. •POWERFULoperationendsin20 minutes.Thenthesystemautomaticallyoperatesagain withtheprevioussettingswhichwereusedbeforePOWERFULoperation. To cancel POWERFUL operation Press •“ again. ”disappearsfromtheLCD. NOTE Notes on POWERFUL operation •Pressing causesthesettingstobecancelled,and“ ”disappearsfromtheLCD. •POWERFULoperationwillnotincreasethecapacityoftheairconditioneriftheairconditionerisalreadyinoperationwithitsmaximumcapacity demonstrated. − In COOL, HEAT and AUTO operation Tomaximizethecooling(heating)effect,thecapacityofoutdoorunitincreasesandtheairflowratebecomesfixedatthemaximumsetting. Thetemperatureandairflowsettingscannotbechanged. − In DRY operation Thetemperaturesettingisloweredby2.5°Candtheairflowrateisslightlyincreased. − In FAN operation Theairflowrateisfixedatthemaximumsetting. Regarding the combination of POWERFUL and other operations POWERFUL + COMFORT AIRFLOW POWERFUL + ECONO POWERFUL + OUTDOOR UNIT QUIET Notavailable* *Priorityisgiventothefunctionofwhicheverbuttonispressedlast. 18 01_EN_3P372379-1C.indd 18 7/9/2014 11:08:22 AM Useful Functions ECONO / OUTDOOR UNIT QUIET Operation ECONO operationenablesefficientoperationbylimitingthemaximum power consumption. Thisfunctionisusefultopreventthecircuitbreakerfromtrippingwhentheunit operatesalongsideotherappliancesonthesamecircuit. OUTDOOR UNIT QUIET operationlowersthenoiseleveloftheoutdoorunitby changingthefrequencyandfanspeedoftheoutdoorunit.Thisfunctionisconvenientduringthenight-timeoperation. To start operation Press and select the desired mode. •Eachtime ECONO ispressed,adifferentsettingoptionisdisplayedontheLCD. OUTDOOR UNIT QUIET Combination blank No Setting To cancel operation Press until no icon is displayed. NOTE Notes on ECONO operation •Pressing causesthesettingstobecancelled,and“ ”disappearsfromtheLCD. •Ifthepowerconsumptionlevelisalreadylow,switchingtoECONOoperationwillnotreducethepowerconsumption. Notes on OUTDOOR UNIT QUIET operation •EveniftheoperationisstoppedbyusingtheremotecontrollerortheindoorunitON/OFFswitchwhenusingOUTDOORUNITQUIEToperation, “ ”willremainlitontheremotecontrollerdisplay. •OUTDOORUNITQUIEToperationwillnotreducethefrequencynorfanspeediftheyalreadyareoperatingatreducedlevels. •Thisoperationisperformedwithlowerpowerandthereforemaynotprovideasufficientcooling(heating)effect. Possible combinations of ECONO / OUTDOOR UNIT QUIET operation and basic operations Operation mode AUTO DRY COOL HEAT FAN ECONO OUTDOOR UNIT QUIET 19 01_EN_3P372379-1C.indd 19 7/9/2014 11:08:23 AM TIMER Operation ON/OFF TIMER Operation Timerfunctionsareusefulforautomaticallyswitchingtheairconditioneronoroff atnightorinthemorning.YoucanalsousetheONTIMERandOFFTIMER together. To use ON TIMER operation •Checkthattheclockiscorrect. Ifnot,settheclocktothepresenttime. 1. Press Page 10 . “ “ ”isdisplayedontheLCD. ”blinks. •“ ”anddayoftheweekdisappearfromtheLCD. 2. Press until the time setting reaches the point you like. •Eachpressingofeitherbuttonincreasesordecreasesthetimesettingby10 minutes. Holdingdowneitherbuttonchangesthesettingrapidly. 3. Press again. •“ ”andsettingtimearedisplayedontheLCD. •TheTIMERlamplightsorange. Display To cancel ON TIMER operation Press . •“ ”andsettingtimedisappearfromtheLCD. •“ ”anddayoftheweekaredisplayedontheLCD. •TheTIMERlampgoesoff. NOTE Notes on TIMER operation •WhenTIMERisset,thepresenttimeisnotdisplayed. •WhenoperatingtheunitviatheON/OFFTIMER,theactuallengthofoperationmayvaryfromthetimeenteredbytheuser.(Maximumabout 10 minutes) In the following cases, set the timer again. •Afterthecircuitbreakerhasturnedoff. •Afterapowerfailure. •Afterreplacingthebatteriesintheremotecontroller. 20 01_EN_3P372379-1C.indd 20 7/9/2014 11:08:24 AM TIMER Operation ON/OFF TIMER Operation To use OFF TIMER operation •Checkthattheclockiscorrect. Ifnot,settheclocktothepresenttime. 1. Press Page 10 . “ “ ”isdisplayedontheLCD. ”blinks. •“ ”anddayoftheweekdisappearfromtheLCD. 2. Press until the time setting reaches the point you like. •Eachpressingofeitherbuttonincreasesordecreasesthetimesettingby10 minutes. Holdingdowneitherbuttonchangesthetimesettingrapidly. 3. Press again. •“ ”andsettingtimearedisplayedontheLCD. •TheTIMERlamplightsorange. Display To cancel OFF TIMER operation Press . •“ ”andsettingtimedisappearfromtheLCD. •“ ”anddayoftheweekaredisplayedontheLCD. •TheTIMERlampgoesoff. To combine ON TIMER and OFF TIMER operation •Asamplesettingforcombiningthe2 timersisshownbelow. (Example) Present time: 23:00 (The unit operating) OFF TIMER at 0:00 Combined ON TIMER at 14:00 NOTE NIGHT SET mode •WhentheOFFTIMERisset,theairconditionerautomaticallyadjuststhetemperaturesetting(0.5°CupinCOOL,2.0°CdowninHEAT)to preventexcessivecooling(heating)duringsleepinghours. 21 01_EN_3P372379-1C.indd 21 7/9/2014 11:08:26 AM TIMER Operation WEEKLY TIMER Operation Upto4timersettingscanbesavedforeachdayoftheweek.ThisisconvenienttoadapttheWEEKLY TIMERtoyourfamily’slifestyle. Setting example of the WEEKLY TIMER ThesametimersettingsareusedfromMondaythroughFriday,whiledifferenttimersettingsareusedfortheweekend. [Monday] Maketimersettingsforprogrammes1-4. Page 23 Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF 8:30 17:30 25°C 27°C 6:00 ON [Tuesday] to [Friday] OFF 22:00 ON OFF UsethecopymodetomakesettingsforTuesdaytoFriday,becausethesesettingsarethesameas thoseforMonday. Page 25 Programme 1 Programme 2 Programme 3 Programme 4 ON OFF ON OFF 8:30 17:30 25°C 27°C 6:00 [Saturday] [Sunday] 22:00 Notimersettings Maketimersettingsforprogrammes1-4. Page 23 Programme 1 Programme 2 Programme 3 Programme 4 ON OFF OFF ON 25°C 8:00 ON 27°C 10:00 OFF 27°C 19:00 OFF 21:00 ON •Upto4 reservationsperdayand28 reservationsperweekcanbesetusingtheWEEKLYTIMER.Theeffectiveuseofthe copymodesimplifiestimerprogramming. •TheuseofON-ON-ON-ONsettings,forexample,makesitpossibletoscheduleoperatingmodeandsettemperature changes.Furthermore,byusingOFF-OFF-OFF-OFFsettings,onlytheturnofftimeofeachdaycanbeset.Thiswillturnoff theairconditionerautomaticallyifyouforgettoturnitoff. 22 01_EN_3P372379-1C.indd 22 7/9/2014 11:08:26 AM TIMER Operation WEEKLY TIMER Operation To use WEEKLY TIMER operation Setting mode •Makesurethedayoftheweekandtimeareset. Ifnot,setthedayoftheweekandtime. Page 10 Programme 1 Programme 2 Programme 3 ON [Monday] OFF Programme 4 ON 25°C OFF 27°C 6:00 8:30 17:30 22:00 Setting Displays Dayandnumber 1. Press ON/OFF Time Temperature . •Thedayoftheweekandthereservationnumberofthecurrentdaywillbedisplayed. •1 to4 settingscanbemadeperday. 2. Press to select the desired day of the week and reservation number. •Pressing 3. Press changesthereservationnumberandthedayoftheweek. . •Thedayoftheweekandreservationnumberwillbeset. ”and“ ”blink. •“ 4. Press •Pressing to select the desired mode. changesthe“ ”or“ ”settinginsequence. blank ON TIMER OFF TIMER No Setting •Incasethereservationhasalreadybeenset,selecting“ blank ”deletesthereservation. •ProceedtoSTEP 9if“ blank ”isselected. •Toreturntothedayoftheweekandreservationnumbersetting,press . 5. Press . •TheON/OFFTIMERmodewillbeset. ”andthetimeblink. •“ 23 01_EN_3P372379-1C.indd 23 7/9/2014 11:08:27 AM TIMER Operation 6. Press to select the desired time. •Thetimecanbesetbetween0:00and23:50in10-minuteintervals. •ToreturntotheON/OFFTIMERmodesetting,press •ProceedtoSTEP 9whensettingtheOFFTIMER. 7. Press . . •Thetimewillbeset. •“ ”andthetemperatureblink. 8. Press to select the desired temperature. •Thetemperaturecanbesetbetween10°Cand32°C. COOLorAUTO:Theunitoperatesat18°Cevenifitissetto10to17°C. HEATorAUTO:Theunitoperatesat30°Cevenifitissetto31to32°C. Page 12 Page 12 •Toreturntothetimesetting,press . •Thesettemperatureisonlydisplayedwhenthemodesettingison. 9. Press . •Thetemperaturewillbesetandgotothenextreservationsetting. •ThetemperatureissetwhileinONTIMERoperation,andthetimeissetwhileinOFF TIMERoperation. •Thenextreservationscreenwillappear. •Tocontinuefurthersettings,repeattheprocedurefromSTEP 4. 10. Press to complete the setting. •Besuretodirecttheremotecontrollertowardtheindoorunitandcheckforareceiving toneandblinkingoftheOPERATIONlamp. •“ ”isdisplayedontheLCDandWEEKLYTIMERoperationisactivated. •TheTIMERlamplightsorange. Display •Areservationmadeoncecanbeeasilycopiedandthesamesettingsusedforanother dayoftheweek.Referto Copy mode . Page 25 NOTE Notes on WEEKLY TIMER operation •Donotforgettosettheclockontheremotecontrollerfirst. Page 10 •Thedayoftheweek,ON/OFFTIMERmode,timeandsettemperature(onlyforONTIMERmode)canbesetwiththeWEEKLYTIMER. OthersettingsfortheONTIMERarebasedonthesettingsjustbeforetheoperation. •WEEKLYTIMERandON/OFFTIMERoperationcannotbeusedatthesametime.TheON/OFFTIMERoperationhaspriorityifitissetwhile WEEKLYTIMERisstillactive.TheWEEKLYTIMERwillenterthestandbystate,and“ ”willdisappearfromtheLCD.WhentheON/ OFFTIMERisup,theWEEKLYTIMERwillautomaticallybecomeactive. •OnlythetimeandsettemperaturewiththeWEEKLYTIMERaresentwiththe .SettheWEEKLYTIMERonlyaftersettingtheoperation mode,theairflowrateandtheairflowdirectionaheadoftime. •Turningoffthecircuitbreaker,powerfailure,andothersimilareventswillrenderoperationoftheindoorunit’sinternalclockinaccurate.Resettheclock. Page 10 • canbeusedonlyforthetimeandtemperaturesettings.Itcannotbeusedtogobacktothereservationnumber. 24 01_EN_3P372379-1C.indd 24 7/9/2014 11:08:29 AM TIMER Operation WEEKLY TIMER Operation Copy mode •Areservationmadeoncecanbecopiedtoanotherdayoftheweek.Thewholereservationof theselecteddayoftheweekwillbecopied. Programme 1 Programme 2 Programme 3 ON [Monday] OFF 25°C 6:00 Programme 4 ON OFF 27°C 8:30 17:30 22:00 COPY Programme 1 Programme 2 Programme 3 [Tuesday] to [Friday] ON OFF 25°C 6:00 Programme 4 ON OFF 27°C 8:30 17:30 22:00 Setting Displays Confirmation 1. Press 2. Press 3. Press Copy Paste Normal . to confirm the day of the week to be copied. . •Thewholereservationoftheselecteddayoftheweekwillbecopied. 4. Press 5. Press to select the destination day of the week. . •Thereservationwillbecopiedtotheselecteddayoftheweek.Thewholereservationof theselecteddayoftheweekwillbecopied. •Tocontinuecopyingthesettingstootherdaysoftheweek,repeatSTEP 4andSTEP 5. 6. Press •“ to complete the setting. ”isdisplayedontheLCDandWEEKLYTIMERoperationisactivated. NOTE Note on COPY MODE •Theentirereservationofthesourcedayoftheweekiscopiedinthecopymode. Inthecaseofmakingareservationchangeforanydayoftheweekindividuallyaftercopyingthecontentofweeklyreservations,press changethesettingsinthestepsof Setting mode . Page 23 and 25 01_EN_3P372379-1C.indd 25 7/9/2014 11:08:30 AM TIMER Operation Confirming a reservation •Thereservationcanbeconfirmed. Setting Displays Normal 1. Press Confirmation . •Thedayoftheweekandthereservationnumberofthecurrentdaywillbedisplayed. 2. Press to select the day of the week and the reservation number to be confirmed. •Pressing displaysthereservationdetails. •Tochangetheconfirmedreservedsettings,selectthereservationnumberandpress Themodeisswitchedtosettingmode.Proceedto Setting mode STEP 4. Page 23 3. Press . to exit the confirmation mode. •“ ”isdisplayedontheLCDandWEEKLYTIMERoperationisactivated. •TheTIMERlamplightsorange. Display To deactivate WEEKLY TIMER operation Press LCD. while “ ” is displayed on the •“ ”disappearsfromtheLCD. •TheTIMERlampgoesoff. •ToreactivatetheWEEKLYTIMERoperation,press •Ifareservationdeactivatedwith willbeused. again. isactivatedonceagain,thelastreservationmode NOTE •Ifnotallthereservationsettingsarereflected,deactivatetheWEEKLYTIMERoperationonce.Thenpress WEEKLYTIMERoperation. againtoreactivatethe 26 01_EN_3P372379-1C.indd 26 7/9/2014 11:08:31 AM TIMER Operation WEEKLY TIMER Operation To delete reservations An individual reservation 1. Press . •Thedayoftheweekandthereservationnumberwillbedisplayed. 2. Press to select the day of the week and the reservation number to be deleted. 3. Press •“ . ”and“ 4. Press •Pressing ”or“ ”blink. until no icon is displayed. changestheON/OFFTIMERmodeinsequence. •Selecting“ blank ”willcancelanyreservationyoumayhave. blank ON TIMER OFF TIMER 5. Press No Setting . •Theselectedreservationwillbedeleted. 6. Press . •Iftherearestillotherreservations,WEEKLYTIMERoperationwillbeactivated. Reservations for each day of the week •Thisfunctioncanbeusedfordeletingreservationsforeachdayoftheweek. •Itcanbeusedwhileconfirmingorsettingreservations. 1. Press 2. Hold to select the day of the week to be deleted. for about 5 seconds. •Thereservationoftheselecteddayoftheweekwillbedeleted. All reservations Hold for about 5 seconds with the normal display. •Besuretodirecttheremotecontrollertowardtheindoorunitandcheckforareceivingtone. •ThisoperationcannotbeusedfortheWEEKLYTIMERsettingdisplay. •Allreservationswillbedeleted. 27 01_EN_3P372379-1C.indd 27 7/9/2014 11:08:32 AM Care Care and Cleaning CAUTION • Beforecleaning,besuretostoptheoperationandturnoffthecircuitbreaker. • Donottouchthealuminumfinsoftheindoorunit.Ifyoutouchthoseparts,thismaycauseaninjury. Quick reference Cleaning parts Front panel •Wipeitwithasoftdampcloth. If dirty Page 29 Air filter •Vacuumdustorwashthefilter. Once every 2 weeks Page 30 Titanium apatite photocatalytic air-purifying filter •Vacuumdustorreplacethefilter. [Cleaning] [Replacement] Once every 6 months • Wipethemwithasoftcloth. Once every 3 years Page 31 Indoor unit, Outdoor unit and Remote controller If dirty Page 31 Notes on cleaning For cleaning, do not use any of the following: •Waterhotterthan40°C •Volatileliquidsuchasbenzene,petrolandthinner •Polishingcompounds •Roughmaterialssuchasascrubbingbrush 28 01_EN_3P372379-1C.indd 28 7/9/2014 11:08:33 AM Care Care and Cleaning CAUTION • Whenremovingorattachingthefrontpanel,standonasolid,stablebaseandtakecarenottofall. • Whenremovingorattachingthefrontpanel,supportthepanelsecurelywithyourhandtopreventitfromfalling. Front panel 1. Open the front panel. •Holdthefrontpanelbythepaneltabsonthe2 sidesandopenit. Panel tab 3. Clean the front panel. •Wipeitwithasoftdampcloth. •Onlyneutraldetergentmaybeused. •Incaseofwashingthepanelwithwater,wipeitwith adrysoftcloth,andletitdryintheshadeafter washing. 4. Attach the front panel. •Alignthefrontpanelshaftontheleftandrightofthe frontpanelwiththegrooves,thenpushthemalltheway in. Front panel shaft Groove 2. Remove the front panel. •Slidethefrontpaneltoeithertheleftorrightand pullittowardyou. Thiswilldisconnectthefrontpanelshaftononeside. 2) Pull Front panel shaft 1) Slide 5. Close the front panel slowly. •Pressthefrontpanelatbothsidesandthecentre. 2) Pull 1) Slide •Disconnectthefrontpanelshaftontheothersidein thesamemanner. •Makesurethatthefrontpanelissecurelyfixed. 29 01_EN_3P372379-1C.indd 29 7/9/2014 11:08:34 AM Care Air filter 1. Open the front panel. Page 29 2. Pull out the air filters. •Pushthefiltertabatthecentreofeachairfiltera littleupwards,thenpullitdown. If the dust does not come off easily • Washtheairfilterswithneutraldetergentthinnedwith lukewarmwater,thenletthemdryintheshade. • Besuretoremovethetitaniumapatitephotocatalytic air-purifyingfilter.Referto“Titanium apatite photocatalytic air-purifying filter”onthenextpage. 1) Push 4. Set the filters as they were. 5. Close the front panel slowly. Page 29 2) Pull down 3. Wash the air filters with water or clean them with a vacuum cleaner. •Itisrecommendedtocleantheairfiltersevery 2 weeks. 30 01_EN_3P372379-1C.indd 30 7/9/2014 11:08:35 AM Care Care and Cleaning Titanium apatite photocatalytic air-purifying filter 1. Open the front panel and pull out the air filters. Page 29,30 2. Take off the titanium apatite photocatalytic air-purifying filters. [Replacement] Remove the filter from the filter frame and attach a new one. •Donotthrowawaythefilterframe.Reusethefilter framewhenreplacingthetitaniumapatite photocatalyticair-purifyingfilter. •Whenattachingthefilter,checkthatthefilteris properlysetinthetabs. •Holdtherecessedpartsoftheframeandunhook the4 claws. •Disposeoftheoldfilterasnon-flammablewaste. Claw 4. Set the titanium apatite photocatalytic air-purifying filters as they were. 3. Clean or replace the titanium apatite photocatalytic air-purifying filters. [Cleaning] 3-1 Vacuum dust, and soak in lukewarm water or water for about 10 to 15 minutes if very dirty. •Donotremovethefilterfromtheframewhen washingwithwater. 3-2 After washing, shake off remaining water and let them dry in the shade. 5. Set the air filters as they were. Page 30 6. Close the front panel slowly. Page 29 NOTE •Operationwithdirtyfilters: −cannotdeodorisetheair, −cannotcleantheair, −resultsinpoorheatingorcooling, −maycauseodour. •Disposeofoldfiltersasnon-flammablewaste. •Toorderatitaniumapatitephotocatalyticair-purifyingfilter,contact thedealerwhereyouboughttheairconditioner. Item Part No. Titaniumapatitephotocatalytic air-purifyingfilter(withoutframe)1 set KAF970A46 •Donotwringoutthefiltertoremovewaterfromit. 31 01_EN_3P372379-1C.indd 31 7/9/2014 11:08:36 AM Care Prior to a long period of non-use 1. Operate the FAN mode for several hours on a fine day to dry out the inside. •Press •Press andselect“ ”. andstarttheoperation. 2. After operation stops, turn off the circuit breaker for the room air conditioner. 3. Take out the batteries from the remote controller. We recommend periodical maintenance •Incertainoperatingconditions,theinsideoftheairconditionermaygetfoulafterseveralseasonsofuse,resultinginpoor performance.Itisrecommendedtohaveperiodicalmaintenancebyaspecialistinadditiontoregularcleaningbytheuser. •Forspecialistmaintenance,pleasecontactthedealerwhereyouboughttheairconditioner. •Themaintenancecostmustbebornebytheuser. 32 01_EN_3P372379-1C.indd 32 7/9/2014 11:08:36 AM When the Need Arises FAQ Indoor unit The flaps do not start swinging immediately. •Theairconditionerisadjustingthepositionoftheflaps. Theflapswillstartmovingsoon. The air conditioner stops generating airflow during HEAT operation. •Oncethesettemperatureisreached,theairflowrateis reducedandoperationstoppedinordertoavoid generatingacoolairflow.Operationwillresume automaticallywhentheindoortemperaturefalls. HEAT operation stops suddenly and a flowing sound is heard. •Theoutdoorunitisdefrosting.HEAToperationstarts afterthefrostontheoutdoorunithasbeenremoved. Thiscantakeabout4to12minutes. Different sounds are heard. A sound like flowing water • Thissoundisgeneratedbecausetherefrigerantin theairconditionerisflowing. • Thisisapumpingsoundofthewaterintheairconditioner andcanbeheardwhenthewaterispumpedoutfromthe airconditionerduringCOOLorDRYoperation. • Therefrigerantflowsintheairconditionerevenif theairconditionerisnotworkingwhentheindoor unitsinotherroomsareinoperation. Blowing sound • Thissoundisgeneratedwhentheflowofthe refrigerantintheairconditionerisswitchedover. Ticking sound • Thissoundisgeneratedwhenthecabinetand frameoftheairconditionerslightlyexpandorshrink asaresultoftemperaturechanges. Whistling sound Operation does not start soon. When was pressed soon after operation was stopped. When the mode was reselected. • Thisistoprotecttheairconditioner. Youshouldwaitforabout3 minutes. • Thissoundisgeneratedwhenrefrigerantflows duringdefrostingoperation. Clicking sound during operation or idle time • Thissoundisgeneratedwhentherefrigerantcontrol valvesortheelectricalpartsoperate. Clopping sound • T hissoundisheardfromtheinsideoftheairconditionerwhen theexhaustfanisactivatedwhiletheroomdoorsareclosed. Openthewindoworturnofftheexhaustfan. Outdoor unit The outdoor unit emits water or steam. In HEAT operation • Thefrostontheoutdoorunitmeltsintowaterorsteamwhentheair conditionerisindefrostingoperation. In COOL or DRY operation • Moistureintheaircondensesintowateronthecoolsurfaceoftheoutdoor unitpipinganddrips. 33 01_EN_3P372379-1C.indd 33 7/9/2014 11:08:36 AM When the Need Arises Troubleshooting Beforemakinganinquiryorarequestforrepair,pleasecheckthefollowing. Iftheproblempersists,consultyourdealer. Not trouble Check Thesecasesarenottroubles. Pleasecheckagainbeforerequesting repairs. The air conditioner does not operate Case OPERATION lamp is off. OPERATION lamp is blinking. Description / what to check • Hasthecircuitbreakerbeentrippedorthefuseblown? • Isthereapowerfailure? • Arebatteriessetintheremotecontroller? • Turnoffthepowerwiththecircuitbreakerandrestartoperationwiththeremotecontroller. IftheOPERATIONlampisstillblinking,checktheerrorcodeandconsultyourdealer. Page 37 The air conditioner suddenly stops operating Case Description / what to check OPERATION lamp is on. • Toprotectthesystem,theairconditionermaystopoperatingaftersuddenlargevoltage fluctuations.Itautomaticallyresumesoperationinabout3minutes. OPERATION lamp is blinking. • Isthereanythingblockingtheairinletorairoutletoftheindoorunitoroutdoorunit? Stopoperationandafterturningoffthecircuitbreaker,removetheobstruction.Thenrestart operationwiththeremotecontroller.IftheOPERATIONlampisstillblinking,checktheerror codeandconsultyourdealer. Page 37 The air conditioner does not stop operating Case The air conditioner continues operating even after operation is stopped. Description / what to check Immediately after the air conditioner is stopped • Theoutdoorunitfancontinuesrotatingforaboutanother1minutetoprotectthesystem. While the air conditioner is not in operation • Whentheoutdoortemperatureishigh,theoutdoorunitfanmaystartrotatingtoprotect thesystem. The room does not cool down / warm up Case Description / what to check Air does not come out. In HEATING operation • Theairconditioneriswarmingup.Waitforabout1to4minutes. • Duringdefrostingoperation,hotairdoesnotflowoutoftheindoorunit. Air does not come out / Air comes out. Is the airflow rate setting appropriate? • Istheairflowratesettinglow,suchas“Indoorunitquiet”or“1”?Increasetheairflowrate setting. Is the set temperature appropriate? Is the adjustment of the airflow direction appropriate? • Isthereanyfurnituredirectlyunderorbesidetheindoorunit? • IstheairconditionerinECONOoperationorOUTDOORUNITQUIEToperation? Page 19 Air comes out. • Aretheairfiltersdirty? • Isthereanythingblockingtheairinletorairoutletoftheindoorunitoroutdoorunit? • Isawindowordooropen? • Isanexhaustfanturning? 34 01_EN_3P372379-1C.indd 34 7/9/2014 11:08:37 AM When the Need Arises Troubleshooting Mist comes out Case Mist comes out of the indoor unit. Description / what to check • ThishappenswhentheairintheroomiscooledintomistbythecoldairflowduringCOOL orotheroperation. Remote controller Case The unit does not receive signals from the remote controller or has a limited operating range. LCD is faint, is not working, or the display is erratic. Other electric devices start operating. Description / what to check • Thebatteriesmaybeexhausted. ReplacebothbatterieswithnewdrybatteriesAAA.LR03(alkaline). Fordetails,referto“Preparation Before Operation”. Page 9 • Signalcommunicationmaybedisabledifanelectronic-starter-typefluorescentlamp(such asinverter-typelamps)isintheroom.Consultyourdealerifthatisthecase. • Theremotecontrollermaynotfunctioncorrectlyifthetransmitterisexposedtodirect sunlight. • Thebatteriesmaybeexhausted. ReplacebothbatterieswithnewdrybatteriesAAA.LR03(alkaline). Fordetails,referto“Preparation Before Operation”. Page 9 • Iftheremotecontrolleractivatesotherelectricdevices,movethemawayorconsultyour dealer. Air has an odour Case The air conditioner gives off an odour. Description / what to check • Theroomodourabsorbedintheunitisdischargedwiththeairflow. Werecommendyoutohavetheindoorunitcleaned.Pleaseconsultyourdealer. Others Case Description / what to check The air conditioner suddenly starts behaving strangely during operation. • Theairconditionermaymalfunctionduetolightningorradio. Iftheairconditionermalfunctions,turnoffthepowerwiththecircuitbreakerandrestartthe operationwiththeremotecontroller. HEAT operation cannot be selected, even though the unit is heat pump model. • Checkthatthejumper(J8)hasnotbeencut.Ifit hasbeencut,contactyourdealer. The ON/OFF TIMER does not operate according to the settings. • CheckiftheON/OFFTIMERandtheWEEKLYTIMERaresettothesametime. ChangeordeactivatethesettingsintheWEEKLYTIMER. Page 22 Notes on the operating conditions •Ifoperationcontinuesunderanyconditionsotherthanthoselistedinthetable, −Asafetydevicemayactivatetostoptheoperation. −DewmayformontheindoorunitanddripfromitwhenCOOLorDRY operationisselected. Mode Jumper (J8) Operating conditions DRY Outdoortemperature:–10-46°C Indoortemperature:18-32°C Indoorhumidity:80%max. COOL Outdoortemperature:–10-46°C Indoortemperature:18-32°C Indoorhumidity:80%max. HEAT Outdoortemperature:–15-24°C Indoortemperature:10-30°C 35 01_EN_3P372379-1C.indd 35 7/9/2014 11:08:37 AM When the Need Arises Call your dealer immediately WARNING When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker. • Continuedoperationinanabnormalconditionmayresultintroubles,electricshocksorfire. • Consultthedealerwhereyouboughttheairconditioner. Do not attempt to repair or modify the air conditioner by yourself. • Incorrectworkmayresultinelectricshocksorfire. • Consultthedealerwhereyouboughttheairconditioner. If one of the following symptoms takes place, call your dealer immediately. • The power cord is abnormally hot or damaged. • An abnormal sound is heard during operation. • The circuit breaker, a fuse, or the earth leakage circuit breaker cuts off the operation frequently. Turnoffthecircuitbreakerandcallyourdealer. • A switch or a button often fails to work properly. • There is a burning smell. • Water leaks from the indoor unit. After a power failure •Theairconditionerautomaticallyresumesoperationinabout3 minutes.Youshouldjustwaitforawhile. Lightning •Ifthereisarisklightningcouldstrikeintheneighbourhood,stopoperationandturnoffthecircuitbreakertoprotectthe system. Disposal requirements •Dismantlingoftheunit,handlingoftherefrigerant,oilandotherparts,shouldbedoneinaccordancewiththerelevantlocal andnationalregulations. 36 01_EN_3P372379-1C.indd 36 7/9/2014 11:08:37 AM When the Need Arises Troubleshooting Fault diagnosis by remote controller •Theremotecontrollercanreceiverelevanterrorcodesfromtheindoorunit. 1. When is held down for about 5 seconds, “ ” blinks in the temperature display section. 2. Press repeatedly until a continuous beep is produced. •Thecodeindicationchangesasshownbelow,andnotifiesyouwithalongbeep. SYSTEM INDOOR UNIT OUTDOOR UNIT CODE 00 UA U0 U2 U4 A1 A5 A6 C4 C9 EA E1 E5 E6 E7 E8 F3 F6 H0 H6 H8 H9 J3 J6 L3 L4 L5 P4 MEANING NORMAL INDOOR-OUTDOORUNITCOMBINATIONFAULT REFRIGERANTSHORTAGE DROPVOLTAGEORMAINCIRCUITOVERVOLTAGE FAILUREOFTRANSMISSION(BETWEENINDOORUNITANDOUTDOORUNIT) INDOORPCBDEFECTIVENESS HIGHPRESSURECONTROLORFREEZE-UPPROTECTOR FANMOTORFAULT FAULTYHEATEXCHANGERTEMPERATURESENSOR FAULTYSUCTIONAIRTEMPERATURESENSOR COOLING-HEATINGSWITCHINGERROR CIRCUITBOARDFAULT OLSTARTED FAULTYCOMPRESSORSTARTUP DCFANMOTORFAULT OVERCURRENTINPUT HIGHTEMPERATUREDISCHARGEPIPECONTROL HIGHPRESSURECONTROL(INCOOLING) SENSORFAULT OPERATIONHALTDUETOFAULTYPOSITIONDETECTIONSENSOR DCCURRENTSENSORFAULT FAULTYSUCTIONAIRTEMPERATURESENSOR FAULTYDISCHARGEPIPETEMPERATURESENSOR FAULTYHEATEXCHANGERTEMPERATURESENSOR ELECTRICALPARTSHEATFAULT HIGHTEMPERATUREATINVERTERCIRCUITHEATSINK OUTPUTOVERCURRENT FAULTYINVERTERCIRCUITHEATSINKTEMPERATURESENSOR NOTE •Ashortbeepand2consecutivebeepsindicatenon-correspondingcodes. •Tocancelthecodedisplay,hold downforabout5seconds.Thecodedisplayalsoclearsifnobuttonispressedfor1minute. 37 01_EN_3P372379-1C.indd 37 7/9/2014 11:08:38 AM Memo 38 01_EN_3P372379-1C.indd 38 7/9/2014 11:08:38 AM Quick Reference The two-dimensional bar code is a manufacturing code. 3P372379-1C M13B344B (1407) HT 00_CV_3P372379-1C.indd 2 7/9/2014 11:07:13 AM
© Copyright 2024