Glulam Beam Connectors Glulam Beam Connectors TOP FLANGE HANGERS GLS/HGLS/GLT/HGLT Beam & Glulam Saddle Hangers See table on page 105. See Hanger Options on pages 233-243 for hanger modifications, which may result in reduced loads. GLT and HGLT accommodate typical structural requirements for timber and glulam beams. GLT top flange depth allows installation on minimum 4x ledger (3 1⁄2" net). Not acceptable for nailer applications. Funnel Flanges® allow easy installation of beams. GLS and HGLS are heavy glulam saddle hangers. MATERIAL: All welded GL series glulam hangers have a 3 gauge top flange. See page 105 for stirrup gauge. FINISH: Simpson Strong-Tie® gray paint. Hot-dip galvanized available; specify HDG. INSTALLATION: • Use all specified fasteners. See General Notes. GLT/HGLT: • All GLTs used with sawn timbers have a 12" L dimension. • Fasteners are included. • GLT may be attached to steel headers by 3⁄16" x 2 1⁄2" fillet welds at each end of the header angle to obtain the tabulated loads. HGLT may be attached to steel headers by 1⁄4" x 2 1⁄2" fillet welds at each end of the header angle to obtain the lesser of the tabulated loads or 12,000 lbs. For uplift loads refer to technical bulletin T-WELDUPLFT. See page 17 for weld information. • Not for use with SCL or LVL headers. See GLTV, HGLTV. GLS/HGLS: • Use Simpson Strong-Tie® ¼"x 2½" SDS Heavy-Duty Connector screws when hangers are used with structural composite lumber. • N54A nails are included with the hangers. • Loads listed are per stirrup. TO ORDER: • GLS/HGLS—Specify H1, H2, and S dimensions (see illustration). • Some engineered wood sizes are also available. OPTIONS: See Hanger Options pages 233-243. 63⁄4 fo " HGr LT GLT Model GLT HGLT GLS HGLS Flatten edge of header to match top flange radius. GLS (HGLT similar) (fasteners included) (fasteners included) Stirrup Width (W) Top Flange Length (L) 2 5⁄8 - 5 1⁄2 10 5 9⁄16 - 6 7⁄8 12 2 5⁄8 - 8 1⁄4 12 8 7⁄8 14 3 1⁄4 - 5 3⁄8 9 6 7⁄8 12 5 1⁄4 - 8 7⁄8 12 HGLS (fasteners included) TOP FLANGE HANGERS LEG/MEG/EG Beam & Glulam Hangers See Hanger Options on pages 233-243 for hanger modifications, which may result in reduced loads. Designed to support large members typically found in glulam beam construction. MATERIAL: See table FINISH: Simpson Strong-Tie gray paint. Hot-dip galvanized available; specify HDG. INSTALLATION: • Use all specified fasteners. See General Notes. • Maintain minimum 4D end distance and edge distance from bolt to end of header and nearest loaded edge per NDS requirements. OPTIONS: • See Hanger Options, pages 233-243. • Models available without top flanges; see table loads. CODES: See page 12 for Code Reference Key Chart. LEG 81⁄4" EG 171⁄2" 3" 11⁄4" 3" LEG/MEG/EG without Top Flange (see options) These products are available with additional corrosion protection. Bolts Dimensions Allowable Loads Without Top Flange Top Flange Joist or Min. Header Joist Model Stirrup 3 Top Flange No Triangle Theory Triangle Theory Purlin Header Min No. Ga W TF Depth Size H Floor Roof Floor Roof Floor Roof Qty Dia Qty Dia (100) (125) (100) (125) (100) (125) 3 1⁄8 LAM LEG3 LEG5 5 1⁄8 LAM MEG5 EG5 LEG7 6 3⁄4 LAM MEG7 EG7 8 3⁄4 LAM EG9 104 7 7 7 7 7 7 7 7 3 1⁄4 5 1⁄4 5 1⁄4 5 1⁄4 6 7⁄8 6 7⁄8 6 7⁄8 8 7⁄8 9 9 9 11 9 9 11 11 1.Roof loads are 125% of floor loads unless limited by other criteria. 2.Allowable loads assume a carrying member width of 5 1⁄2". 3.Specify H dimension. 2 1⁄2 2 1⁄2 2 1⁄2 2 1⁄2 2 1⁄2 2 1⁄2 2 1⁄2 2 1⁄2 EG with “H” dimension less than the face plate height. The EG’s back plate is always 17 1⁄2", regardless of the stirrup height. EG LEG and MEG 10 10 13 20 10 13 20 20 4 4 6 8 4 6 8 8 ⁄4 ⁄4 3 ⁄4 1 3 ⁄4 3 ⁄4 1 1 3 3 2 2 2 2 2 2 2 2 ⁄4 ⁄4 3 ⁄4 1 3 ⁄4 3 ⁄4 1 1 3 3 3465 3465 5170 8870 3465 5170 8870 8870 4330 4330 6460 11085 4330 6460 11085 11085 12675 16290 19710 20895 16290 19710 25320 25320 13215 16290 19710 21815 16290 19710 25835 25835 13040 13040 14835 17885 13040 14885 19290 20080 13865 13865 16860 19865 13865 16060 21275 22875 Code Ref. Model I19, F18, L14 LEG/MEG EG5 EG7 EG9 4. Triangle Theory: Some code jurisdictions allow only half of the top flange bearing area to be considered when performing a top flange hanger calculation as there is non-uniform stress under the top flange (presumed to be a triangular shaped distribution). Therefore, loads are published above using the calculated “Triangle Theory”. Loads are also published in the “No Triangle Theory” columns which are based on calculations assuming full bearing on the top flange which do not exceed the tested value with a reduction factor of 3. Top Top Flange Flange Length Ga (L) 7 3 12 11 3⁄4 13 1⁄2 15 1⁄2 C-C-2015 © 2015 SIMPSON STRONG-TIE COMPANY INC. PRINTED 12/14 MEG 111⁄4"
© Copyright 2024