37-MO-111 spec sheet - Cook-N

BUILT-IN DUAL-BURNER
TEPPAN GRILL TOP
CHEF EDITION MO-111
®
PATENTED SHALLOW-DIP-TECHNOLOGY + CONTACT HEAT
TEPPANYAKI GRILL COOK TOP SPECIFICATIONS
Size: L 44” x W 24” (111.8 x 60.9 cm)
8WILL NOT FIT OVER STANDARD 24” CABINETS
24”
60.9 cm
44” | 111
.8 cm
2 x ~330 square inch HOT SPOT
Total cooking area ~800 sq/in incl. warming
INDOOR + OUTDOOR USE | IPX4 RATED
HOT cooking center
~45 cm x ~45 cm
Material: Prof. Food Grade Best Alloy
German Stainless Steel type 304 (V2A)
5/32” thick (4 mm) cold pressed, handwelded. Built-to-last. Silk-brushed finish.
5
ULTRA
SLIM !
2x 1800 Watt | 1.8 kWh on high
120V | 50-60 Hz | 2x 15 AMP
240V | 50-60 Hz | 2x 8 AMP
2x 2250 Watt | 240V | 2x 10 AMP
5 Year ltd. Warranty. Electrical + electronic
parts: 1 year limited manufacturers’.
CE/ GS/ VDE Safety Certificate. Electrical +
Electronic Components: UL approved.
1
L ed
ges
HOT Cooking Center
~17-3/4” x 17-3/4”
4
Only 1-5/8”
built-in height
(41 mm)
25
3
4
6
7
TWO (2) SEPARATELY CONTROLLABLE BURNERS | 2 x 1800W or ProStyle 2250W
SHOWN: CONTROL BOX “B”
2
CONTROL OPTIONS:
- control box ”A” for under mount + outdoors
“A” box
- control box “B” for concealed mounting
3
Ship weight: 88 lbs.| ship size 55” x 34” x 6”
Ship weight: 40 kg | ship size 141 x 87 x 15 cm “B” box front plate
1
2
3
4
5
6
7
SOLID 304 STAINLESS STEEL GRILL TOP
CONTROL BOX “A” for undermount + outdoor use
BOX “B” visible front plate + temperature dial
FLEXIBLE CONDUIT
INSULATED HEATING ELEMENT ENCLOSURES
CONTROL BOX “B” MOUNTING HOLES
STAINLESS STEEL MOUNTING STUDS
1-3/4” long (45 mm) | 3/16” Ø (5 mm)
304 stainless steel washers + nuts included
8 2x 10 FT POWER CORDS included
Custom-made mobile Corian Grill Cart Design: Q4U, Belgium
Model MO-111 shown with dual ventilation. Accessories not included. Cook-N-Dine® reserves the right to update, alter or discontinue any model without notice any time.
SINCE 1887 - OVER 125 YEARS OF INNOVATION & PRECISION MANUFACTURING
©2014 p&p | www.cookndine.com
Analog temperature control:
1-10 dial | 2 indicator lights | thermostat
Contact Heat: 150ºF to 450ºF (65º-230ºC)
COO
German Stainless steel production uses up to 80% recycled raw material
Power:
Electric:
alt.
ProStyle
~1”
~2.5” warm
BUILT-IN TEPPAN
DUAL BURNER
model MO-111
INSTALL SHEET 1 of 2
Electrical Rating: 120V |2x 1800 Watt |2x 15 AMP | 50-60 Hz
1.8 kWh on high (alt. 240V/1800 Watt, 8 AMP or ProStyle 2250W-240V, 10 AMP)
8ALWAYS Check control box label for correct voltage BEFORE plugging in!
Bolts are 1-3/4 inch (45 mm) long; bolt diameter is 13/64ӯ (5 mm)
8drill 5/16ӯ
(8 mm)
!!! IMPORTANT: DO NOT DRILL NOR CUT ANY HOLES BEFORE UNIT IS PHYSICALLY PRESENT
! ! ! DO NOT CUT OFF THE BOLTS ! ! !
44 inch | 1118 mm
24 inch
609 mm
conduit lengths
~19.5” ea.
(~500 mm)
9 ft (3 m)
power cords
CUTOUT
21.614 inch
549 mm
CUTOUT
21-1/4 inch
540 mm
MANDATORY CUTOUT
41.654 inch | 1058 mm
8
NOTE:
DRAWING IS NOT
TO SCALE
The Control Box MUST be firmly fastened to a NON-MOVING surface.
8 CAUTION: DO NOT SNAP, PULL or TWIST THE CONDUIT DURING INSTALLATION ! ! !
Warranty expires if capillary tube (thermostat) inside the conduit is damaged during installation.
1. Mark bolt holes, drill 5/16 inch Ø | 8 mm Ø - bolts will fit holes loosely. Clean counter surface thoroughly!!!
2. Clean underside edges of unit with rubbing alcohol or similar.
Apply thin bead of Silicone Sealant around the edges of the underside of the unit. Do not leave any gaps.
This protects from potential moisture intrusion, especially when installed outside without overhead cover.
!!! IMPORTANT NOTE: MAKE SURE TO PREVENT SILICONE FROM GETTING INTO THE BOLT HOLES !!!
Press evenly down to compress Silicone. Secure with supplied nuts and washers from underneath.
Find all nuts, washers and the extension key for “B” control in a small plastic bag inside the pouch.
!!! IMPORTANT: Tighten nuts with hand tool only. Do not use any power tools!!!
4. Mark, drill and fasten the control box into place 8REFER TO SEPARATE INSTALL SHEET FOR “B” CONTROL
Optional: seal the round metal plate with Silicone to prevent potential moisture intrusion.
Now connect the power cord VERY FIRMLY to the rear of the control box. Connect the electrical 3-prong plug
(other end) to a properly grounded power outlet. IMPORTANT: Check control box label for correct voltage!!!
©2014 p&p | www.cookndine.com
3. Slide cook top into place. Do not apply excessive force. Unit needs to go in without any resistance.
BUILT-IN TEPPAN
INSTALLATION DETAIL
PAGE 2 of 2
Bolts/studs are 1-3/4 inch (45 mm) long; bolt/stud diameter is 3/16ӯ (5 mm)
VERY IMPORTANT:
8drill 5/16ӯ
(8 mm) !!!
8DO NOT CUT OR DRILL BEFORE UNIT IS PHYSICALLY PRESENT. DO NOT CUT OFF THE BOLTS/STUDS!
8 MM | 5/16” REQUIRED HOLE DIAMETER
5 MM | 3/16” BOLT DIAMETER
COOK-TOP
CND TEPPANYAKI
HEATING
ELEMENT
ENCLOSURE
CUTOUT
36 mm
1.41”
R
E
NT
U
CO
ANGLE
BRACKET 304
PRE-PUNCHED
(MO-80 only)
IMPORTANT:
WHEN INSERTING THE UNIT,
THE STUDS MUST SLIDE
INTO THEIR DESIGNATED
HOLES EASILY AND
! ! ! WITHOUT ANY RESISTENCE ! ! !
TIGHTEN THE NUTS WITH A HAND WRENCH.
DO NOT USE FORCE OR POWER TOOLS.
REPEAT AFTER A COUPLE OF USES.
3-4 MM material strength
Optional:
Route metal thickness
P for flush installation
10 mm
3/8”
20 mm
3/4”
P
TO
T
ER
C
N
OU
TO
RODDING:
inserted epoxied metal rod
to re-inforce stone counter
(also see OFFICIAL MIA INFO)
WASHER
LOCK WASHER
NUT
STUD
NOTE: DRAWINGS ARE NOT TO SCALE.
COUNTER SINK
nuts if necessary
8ATTENTION !!! MUST READ !!! INSTALLATION INTO STONE/GRANITE COUNTER TOPS 7
RODDING is a professional business practice for porous, fissured or “brittle” Natural Stone/Granite. The narrow
areas of material are reinforced on the underside surrounding large cutouts (e.g. for sinks, stoves, cook tops).
This will support and strengthen those areas and is intended to prevent possible damage.
CND offers 304 stainless steel custom-made 12 gauge pre-punched angle brackets (order separately, for
MO-80 only) which can be installed along the full length of the cutout (both long sides). The unit is fastened
through the bracket’s holes (see above). Stress applied to the counter material during operation should thus be
evenly distributed. VERY IMPORTANT: The use of brackets cannot guarantee the prevention of damage.
Everything strictly depends on the natural properties of the counter top material. Therefore, Cook-N-Dine cannot be held responsible for any type of damage to stone counter tops. Also see Marble Institute of America Info.
Make sure to HAVE THE UNIT and ALL install sheets ON SITE ahead of time for counter top templating!
8 CAUTION: DO NOT SNAP, PULL or TWIST THE CONDUIT DURING INSTALLATION ! ! !
Warranty expires if capillary tube inside the conduit (thermostat) is damaged during installation.
Control box must be firmly fastened to a non-moving surface.
©2014 p&p | www.cookndine.com
Please be reminded that the CND stainless steel grill surface will flex slightly when switched on thus
developing a shallow dip in the cooking center. This motion is intended and is counteracted by the secured
bolts, which hold the unit in place. If you install into a natural stone or granite counter-top, please talk to your
supplier/installer about your plans. You must provide them with a full set of install sheets ahead of time. A stone
professional will be able to advise you on any aspects to watch out for, e.g. on how much counter-top (“meat”)
is necessary at the narrowest point for the particular stone of choice to accommodate a Cook-N-Dine built-in
appliance properly. MO-80: Minimum 6 inches from counter edge to edge of cook top are strongly advised.
PLEASE NOTE: COUNTER TOP THICKNESS OF 1.5 IN (40 mm) IS MANUFACTURER RECOMMENDED
UNLESS MATERIAL HAS BEEN RE-INFORCED BY MEANS OF RODDING OR COMPARABLE.
BUILT-IN TEPPAN
TYPE “B” CONTROL BOX
CONCEALED MOUNT
8 CAUTION: DO NOT SNAP, PULL or TWIST THE CONDUIT DURING INSTALLATION ! ! !
Warranty will expire if capillary tube inside the conduit is damaged during installation.
Control box must be firmly fastened to a non-moving surface.
interior 8 VERY IMPORTANT NOTE: Do not open the control box or warranty expires!
cabinet
cabinet space
wall
102
4” (
)
mm
”
5-3/8
(137
mm)
3” (76 mm)
Control
Light
Sockets
Hole for
fastening
screws
Control/Indicator Light
Plastic Caps
Prongs prevent
light sockets from
slipping into box only
Holes for screws
to attach
plate
Stem for
dial knob
2(60 3/8”
mm
)
Hole
for
stem
Hollow Stem
Extension
0
Stainless
Steel Plate
3-1/8“ dia (80 mm)
Hole
for fastening screws
exterior
dial knob
DIRECTIONS:
1. Remove packaging and carefully pull off the DIAL KNOB ONLY while holding on to the round plate. Do not use force or tools!
2. Now separate the round steel plate from Control Light Sockets by carefully wiggling it away WITH the yellow and green light plastic caps
Hold one with two fingers and gently pull plate away; repeat with other. Yellow and green PLASTIC CAPS STAY IN PLACE in the plate.)
3. Mark all necessary holes utilizing the provided template below. Drill required holes and gently thread light sockets through their
designated openings. DO NOT SNAP THE PRONGS! Now fasten the box to interior of cabinet wall or underneath counter top.
4. Gently pull light sockets out a little bit and re-connect with plastic caps in the metal plate; affix plate with two small flathead screws, or
silicone into place. CAUTION: DO NOT TWIST OR SNAP DELICATE WHITE WIRING OF INDICATOR LIGHTS.
5. Connect the hollow extension to stem if needed (packed with nuts + washers). Slide dial knob onto stem (match flat side of stem
with flat side of female receptacle at back of knob). Do not use force. The “0” has to align centered below the CDS logo.
7 mm
1 17/32"
1 17/32"
39 mm
7 mm
39 mm
46 mm
ø 7/32”
6 mm
ø 5/8”
GREEN
16 mm
YELLOW
ø 9/64”
3.6 mm
18 mm
11/16"
ø 7/32”
6 mm
ø 9/64”
3.6 mm
ø 3/8”
ø 9/64”
3.6 mm
10 mm
ø 9/64”
3.6 mm
4 7/8"
124 mm
5 3/8"
8137 mm - PLEASE MEASURE ACROSS TO MAKE SURE TEMPLATE IS 1:1
©2014 p&p | www.cookndine.com
18 mm
11/16"
1 13/16 in
IMPORTANT: To use as 1:1 template
set “page scaling” to “none” when printing
9/32"